Theory of Chromatography



Similar documents
Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Diffusion and Fluid Flow

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x

Chapter 21 Principles of Chromatography and Mass Spectrometry Problems 1,2,3,4,8,9,11,13

The Theory of HPLC. Gradient HPLC

Fractional Distillation and Gas Chromatography

The van Deemter Equation:

Fluid Mechanics: Static s Kinematics Dynamics Fluid

Retention Parameters in Column Chromatography

Introduction to HPLC. Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke. Introduction to HPLC p.1/17

Energy Transport. Focus on heat transfer. Heat Transfer Mechanisms: Conduction Radiation Convection (mass movement of fluids)

FLUID DYNAMICS. Intrinsic properties of fluids. Fluids behavior under various conditions

Lecture 24 - Surface tension, viscous flow, thermodynamics

1. Fluids Mechanics and Fluid Properties. 1.1 Objectives of this section. 1.2 Fluids

Separation of Amino Acids by Paper Chromatography

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Vacuum Technology. Kinetic Theory of Gas. Dr. Philip D. Rack

Background Information

SIZE OF A MOLECULE FROM A VISCOSITY MEASUREMENT

10.7 Kinetic Molecular Theory Kinetic Molecular Theory. Kinetic Molecular Theory. Kinetic Molecular Theory. Kinetic Molecular Theory

Basic Equations, Boundary Conditions and Dimensionless Parameters

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Paper Chromatography: Separation and Identification of Five Metal Cations

Kinetic Theory of Gases. Chapter 33. Kinetic Theory of Gases

Fluids and Solids: Fundamentals

Ferda ORHUN Mineral Research and Exploration Institute of Turkey

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

GAS CHROMATOGRAPHY. DETERMINING THE PERCENT COMPOSITION OF A MIXTURE OF VOLATILE LIQUIDS USING A GAS CHROMATOGRAPH. (Revised: )

Chapter 5: Diffusion. 5.1 Steady-State Diffusion

A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW ASME Fluids Engineering Division Summer Meeting

Ch 2 Properties of Fluids - II. Ideal Fluids. Real Fluids. Viscosity (1) Viscosity (3) Viscosity (2)

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE Dr. Alan Doolittle

Table 9.1 Types of intrusions of a fluid into another and the corresponding terminology.

Natural Convection. Buoyancy force

The Viscosity of Fluids

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Alignment and Preprocessing for Data Analysis

where h = J s

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

IDEAL AND NON-IDEAL GASES

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Viscoelasticity of Polymer Fluids.

Purification of reaction mixtures using flash chromatography.

CH3 Stoichiometry. The violent chemical reaction of bromine and phosphorus. P.76

Gas Chromatography Liner Selection Guide

Gases. States of Matter. Molecular Arrangement Solid Small Small Ordered Liquid Unity Unity Local Order Gas High Large Chaotic (random)

Carbon Cable. Sergio Rubio Carles Paul Albert Monte

Stability of Evaporating Polymer Films. For: Dr. Roger Bonnecaze Surface Phenomena (ChE 385M)

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

4. Introduction to Heat & Mass Transfer

Signal, Noise, and Detection Limits in Mass Spectrometry

Lecture 5 Hemodynamics. Description of fluid flow. The equation of continuity

Addressing the World Helium Shortage For Gas Chromatography

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

Battery Thermal Management System Design Modeling

DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED

HPLC Basics, Equipment, and Troubleshooting

1A Rate of reaction. AS Chemistry introduced the qualitative aspects of rates of reaction. These include:

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Lab 6: Paper Chromatography. Pages Pre-lab page 151 No Post lab Chromatogram must be turned in attached to lab report

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

Problem Set 12: Kinetic Theory; Mechanical Equivalent of Heat Solutions

CHAPTER: 6 FLOW OF WATER THROUGH SOILS

The University of Toledo Soil Mechanics Laboratory

momentum change per impact The average rate of change of momentum = Time interval between successive impacts 2m x 2l / x m x m x 2 / l P = l 2 P = l 3

Physics Lab Report Guidelines

Swissmetro travels at high speeds through a tunnel at low pressure. It will therefore undergo friction that can be due to:

Measurement of the viscosities of He, Ne and Ar for the determination of their gas kinetic diameters.

Ground Rules. PC1221 Fundamentals of Physics I. Kinematics. Position. Lectures 3 and 4 Motion in One Dimension. Dr Tay Seng Chuan

Experiment 5: Column Chromatography

The Use of Hydrogen Carrier Gas for GC/MS

Basic Principles in Microfluidics

Notes on Polymer Rheology Outline

99.37, 99.38, 99.38, 99.39, 99.39, 99.39, 99.39, 99.40, 99.41, cm

Name Class Date. In the space provided, write the letter of the term or phrase that best completes each statement or best answers each question.

PAPER CHROMATOGRAPHY

XI / PHYSICS FLUIDS IN MOTION 11/PA

Section 5.0 : Horn Physics. By Martin J. King, 6/29/08 Copyright 2008 by Martin J. King. All Rights Reserved.

A Comparison of Analytical and Finite Element Solutions for Laminar Flow Conditions Near Gaussian Constrictions

Thermodynamics of Mixing

Paul Clements, SpR in Anaesthetics, Hope Hospital, Salford, UK. Carl Gwinnutt, Consultant Anaesthetist, Hope Hospital, Salford, UK.

Lecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics

A Complete Solution for Method Linearity in HPLC and UHPLC

1. The Kinetic Theory of Matter states that all matter is composed of atoms and molecules that are in a constant state of constant random motion

Dimensional Analysis

VISUAL PHYSICS School of Physics University of Sydney Australia. Why do cars need different oils in hot and cold countries?

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Expectations for GC-MS Lab

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

INTRODUCTION. The principles of which are to:

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

Chapter 2 Theory of Gas Chromatography

Resistivity. V A = R = L ρ (1)

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

Aim : To study how the time period of a simple pendulum changes when its amplitude is changed.

Transcription:

Theory of Chromatography

The Chromatogram A chromatogram is a graph showing the detector response as a function of elution time. The retention time, t R, for each component is the time needed after injection of the mixture until that component reaches the detector.

The Chromatogram (cont.) Retention volume, V R, is the volume of mobile phase required to elute a particular solute from the column: V R = t R F where F is the mobile phase flow rate The dead time, t m, is the time of travel of unretained mobile phase through the column.

The Chromatogram (cont.) The adjusted retention time, t R, for a solute is the additional time required for solute to travel the length of the column beyond the time required by unretained solvent: t R = t R t m In GC, t m is usually taken as the time needed for CH 4 to travel through the column.

The Chromatogram (cont.) For any two components 1 and, the relative retention, α, is the ratio of their adjusted retention times: where, so α > 1. ' 1 ' R R t t = α 1 R R t t = 1 R R t t = ' 1 ' R R t t = ' 1 ' R R t t >

The Capacity Factor For each peak in the chromatogram, the capacity factor, k, is defined as: k' = t R t m t m k'= time solute spends in stationary phase time solute spends in mobile phase

The Capacity Factor (cont.) time solute spends in stationary phase k' = = time solute spends in mobile phase moles of solute in stationary phase moles of solute in mobile phase k ' = C V C s m V s m k ' = K C C V V s m s m = K t = R t m t m = t t ' R m

Relative Retention Alternative Expressions α = t t ' R ' R1 = k k ' ' 1 = K K 1

Efficiency of Separation

Resolution Solute moving through a column spreads into a Gaussian shape with standard deviation σ. Common measures of breadth are: The width w ½ measured at half-height The width w at the baseline between tangents drawn to the steepest parts of the peak (inflection points).

Resolution (cont.) It can be shown that: and w ½ =.35σ w = 4σ

Resolution (cont.) In chromatography, the resolution of two peaks from each other is defined as R s = Δt w R av = ΔV w av R = 0.589Δt w 1 av R where Δt R or ΔV R is the separation between peaks and w av is the average width of the two peaks.

Resolution So, separation of mixtures depends on: width of solute peaks (want narrow) efficiency spacing between peaks (want large spacing) selectivity

Example What is the resolution of two Gaussian peaks of identical width (3.7 s) and height eluting at 67.3 s and 74.9 s, respectively? ANS: Resolution =.3

Diffusion A band of solute broadens as it moves through a column. Ideally, an infinitely narrow band applied to the inlet of the column emerges with a Gaussian shape at the outlet.

Diffusion (cont.) One main cause of band spreading is diffusion. The diffusion coefficient measures the rate at which a substance moves randomly from a region of high concentration to a region of lower concentration.

Diffusion (cont.) The number of moles crossing each square meter per second, called the flux, is proportional to the concentration gradient: flux mol m s J = D dc dx

Broadening of Chromatographic Band by Diffusion If solute begins to move through a column in an infinitely sharp layer with m moles per unit crosssectional area of the column and spreads by diffusion alone, then the Gaussian profile of the band is described by c = m e x ( 4Dt ) 4 π Dt

The standard deviation of the band is σ = Dt

The Theory of Chromatography: Column Efficiency Plate theory - older; developed by Martin & Synge Rate theory - currently in use

Plate Theory - Martin & Synge View column as divided into a number (N) of adjacent imaginary segments called theoretical plates within each theoretical plate complete equilibration of analytes between stationary and mobile phase occurs

Plate Theory - Martin & Synge Significance? Greater separation occurs with: greater number of theoretical plates (N) as plate height (H or HETP) becomes smaller L = N H or H = L / N where L is the length of column, N is the number of plates, and H is the plate height

First Important Prediction of Plate Theory Band spreading - the width of bands increases as their retention time (volume) increases: Plate height is the constant of proportionality between the variance of the band and the distance it has traveled: σ = Dt = D u x x D = x = u x Hx

Second Significant Prediction of Plate Theory The smaller HETP, the narrower the eluted peak

Plate Theory - Practical Considerations Not unusual for a chromatography column to have millions of theoretical plates Columns often behave as if they have different numbers of plates for different solutes present in same mixture

Number of plates on column: N V = 16 w w b base width of the peak R b This equation is a measure of the efficiency of a column.

Sometimes the number of plates is measured at the bandwidth at half-height w 1/ : N = 5.54 V w R 1

Estimating the Plate Number for Asymmetric Peaks The Dorsey-Foley equation: N = 41.7 t R w0.1 A + 1.5 B

N can be Estimated Experimentally from a Chromatogram Knowing the number of theoretical plates and the length of the column, we can determine the HETP, height equivalent to a theoretical plate: H = HETP = L N = L 16 w V b R = L 16 w t b R

Effective Number of Theoretical Plates Introduced to characterize open tubular columns uses adjusted retention volume V R in lieu of total retention volume V R : b ' b ' eff 16 16 = = w t w V N R R

Effective Number of Theoretical Plates (cont.) The N eff value is useful for comparing a packed and an open tubular column when both are used for the same separation. N and N eff are related by the expression N eff = N k' k' + 1

Rate Theory Based on a random walk mechanism for the migration of molecules through a column Takes into account: mechanism of band broadening effect of rate of elution on band shape availability of different paths for different solute molecules to follow diffusion of solute along length

Van Deemter Equation for Plate Height B H = A + + u x Cu x Multiple paths Longitudinal diffusion Equilibration time

In packed columns, all three terms contribute to band broadening In open tubular columns, A is zero In capillary electrophoresis, both A and C go to zero

H = A + min B C H = A + min BC u opt = B C

Longitudinal Diffusion Gives rise to B/u x term Solute continuously diffuses away from the concentrated center of its zone The greater the flow rate, the less time is spent in the column and the less longitudinal diffusion occurs

Longitudinal Diffusion (cont.) The variance resulting from diffusion is σ = D m t = D u m x L Plate height due to longitudinal diffusion: H D = σ L = D u x m B u x

Longitudinal Diffusion (cont.) In packed columns, the tortuosity coefficient γ is used to account for irregular diffusion patterns and is usually less than unity (γ ~ 0.6), because molecular diffusivity is smaller in packed columns than in open tubes (γ = 1): H D = γd u x m

Longitudinal Diffusion (cont.) Because longitudinal diffusion in a gas is much faster than in a liquid, the optimum flow rate in gas chromatography is higher than in liquid chromatography

Nonequilibrium (Resistance to Mass Transfer Term) This term comes from the finite time required for the solute to equilibrate between the mobile and stationary phases Some solute is stuck in the stationary phase, but the remainder in the mobile phase moves forward resulting in spreading of the zone The slower the flow rate, the more complete equilibration is and the less band broadening occurs

Resistance to Mass Transfer (cont.) Plate height due to finite equilibration time: H = Cu = + mass transfer x ( C ) s Cm ux where C s describes the rate of mass transfer through the stationary phase and C m describes the rate of mass transfer through the mobile phase. Specific equations for C s and C m depend on the type of chromatography.

Resistance to Mass Transfer (cont.) For gas chromatography in an open tubular column, the terms are: Mass transfer in stationary phase: Mass transfer in mobile phase: ( ) s f s D d k k C 1 ' 3 ' + = ( ) m m D r k k k C 1 ' 4 ' 11 ' 6 1 + + + =

Resistance to Mass Transfer (cont.) k the capacity factor d f the thickness of stationary phase film D s the diffusion coefficient of solute in the stationary phase r the column radius D m the diffusion coefficient of solute in the mobile phase

Resistance to Mass Transfer (cont.) Efficiency is increased by: Decreasing stationary phase thickness Reducing column radius Increasing temperature

Multiple Flow Paths (Eddy Diffusion) The term A accounts for the multitude of pathways that could be followed through the column by one molecule: A = λd p λ dimensionless constant characteristic of packing d p the particle diameter

Multiple Flow Paths (Eddy Diffusion) (cont.) The A term can be minimized by: Eliminating column packing (open tubular columns) Reducing the particle size of the packing Packing the column more uniformly (spherical particles of similar size)

Alternative Plate Height Equation: The Knox Equation Used to compare column efficiencies Makes use of so-called reduced parameters (dimensionless quantities): Reduced plate height: h = H/d p Reduced velocity: v = ud p /D m 1 b 3 h = aν + + ν cν

The Knox Equation (cont.) For well-packed columns of varying particle size and differing conditions, the coefficients a, b and c will be roughly constant: e.g. a =1, b =, and c = 0.05 for porous particles.

Modification of the van Deemter Equation: the Giddings Equation Giddings realized that the eddy diffusion and resistance to mass transfer in the mobile phase must be treated dependently: 5 1 B H = + + Csu + Cmu + 1 i + 1 = 1 u A C u 1 H e

The Giddings Equation H e extracolumn band broadening C 1 = c b d D m p c b a proportionality constant; c b 1

The Giddings Equation (cont.) The five possible mechanisms of band broadening are: Through channels between particles Through particles Resulting from uneven flow channels Between inhomogeneous regions Throughout the entire column length

Factors Affecting Resolution A more usable expression for resolution is R s α 1 1 k' = N 4 α k' + 1 efficiency selectivity retention

Required Plate Number If k and α are known, the required number of plates can be calculated: The R s value is set at the 6σ level or 1.5 ' ' req 1 1 16 + = k k R N s α α ' ' req 1 1 16 + = k k R N s α α

Required Column Length The N req parameter can be used to determine the length of column necessary for a separation. We know that N = L/H; thus ' ' req 1 1 16 + = k k H R L s α α

Minimum Analysis Time The minimum analysis time t min is t min = 16R s H u α α 1 ( ' k ) + 1 ( ' k ) 3

The Major Objective in Chromatography The goal in chromatography is the highest possible resolution in the shortest possible time. Optimization techniques aim at choosing conditions that lead to a desired degree of resolution with a minimum expenditure of time

Optimization Techniques Minimizing plate height: Reducing d p Reducing column diameter Changing column temperature Reducing the thickness of the liquid film Optimizing the flow rate of the mobile phase

Optimization Techniques (cont.) Resolution also improves with L, but it expensive in terms of time of analysis Variation in the selectivity factor: Changing the composition of the mobile phase (in HPLC) Changing the column temperature Changing the stationary phase Using special chemical effects

Effect of Capacity Factor on Resolution and Elution Time Increases in k enhance resolution but at the expense of elution time The optimum k values are from 1 to 5 The easiest way to improve R s is by optimizing k In GC, k can be improved by temperature programming In LC, k is improved by gradient elution

Advantages of Open Tubular Columns Compared with packed columns, open tubular columns can provide: Higher resolution Shorter analysis time Increased sensitivity Lower sample capacity

Advantages of Open Tubular Columns (cont.) Compared with packed columns, open tubular columns allow Increased linear flow rate or a longer column or both Decreased plate height, which means higher resolution

A Touch of Reality: Asymmetric Bandshapes