Dr.Ir. Ing. Dick G. Klaren and Ing. Eric F. de Boer KLAREN BV, Hillegom, the Netherlands



Similar documents
Examples for Heat Exchanger Design

5.2. Vaporizers - Types and Usage

Corrugated Tubular Heat Exchangers

Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger

SURVEY OF LONG TIME BEHAVIOR AND COSTS OF INDUSTRIAL FLUIDIZED BED HEAT EXCHANGERS

Design of heat exchangers

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

Fluid Mechanics: Static s Kinematics Dynamics Fluid

Outotec HIGmills; A Fine Grinding Technology

Flow distribution and turbulent heat transfer in a hexagonal rod bundle experiment

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES

Open Channel Flow Measurement Weirs and Flumes

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

1 DESCRIPTION OF THE APPLIANCE

Babcock & Wilcox's IR-CFB Boiler Technology. S. P. Ganeshan. Papertech -2010, Hyderabad. Divisional Manager, Thermax Limited, Boilers & Heaters Group

I. STEAM GENERATION, BOILER TYPES

The soot and scale problems

Liquid Distributors. Liquid Redistribution. Liquid Distribution. INTALOX Distributors

Hydraulic Jumps and Non-uniform Open Channel Flow, Course #507. Presented by: PDH Enterprises, LLC PO Box 942 Morrisville, NC

Efficiency on a large scale CFB Steam Boilers

Battery Thermal Management System Design Modeling

2.2. Basic Equations for Heat Exchanger Design

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

Energy Efficient Data Center Design. Can Ozcan Ozen Engineering Emre Türköz Ozen Engineering

Filter Aid Filtration

LESSON 1. HEAT EXCHANGERS

Control ball valves for severe services. Author: Michele Ferrante, PARCOL S.p.A., Italy

TANKJKT. Heat Transfer Calculations for Jacketed Tanks SCREEN SHOTS. Copyright By chemengsoftware.com

DECANTER CENTRIFUGE. CENTRIFUGE TECHNOLOGIES

Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water

VALIDATION, MODELING, AND SCALE-UP OF CHEMICAL LOOPING COMBUSTION WITH OXYGEN UNCOUPLING

TUBE-TO-TUBESHEET JOINTS: THE MANY CHOICES ABSTRACT KEYWORDS. Seal welding, tube-to-tubesheet welds, heat exchanger, mock-up, tube expansion

HVAC air curtains. Type InduAir

Transformer oil cooler ALFA A02

Heat transfer in Rotating Fluidized Beds in a Static Geometry: A CFD study

Shell and Tube Heat Exchanger Design Software for Educational Applications*

Heat Exchangers. Plate-and-Frame COMPACT HEAT EXCHANGERS PART 1: heat exchangers. Use these design charts for preliminary sizing.

Practice Tests Answer Keys

HW Set VI page 1 of 9 PHYSICS 1401 (1) homework solutions

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

POURING THE MOLTEN METAL

Selecting TEMA Type Heat Exchangers

Chapter 3.5: Fans and Blowers

Innovation and Progress in Water Treatment Technology

Background. 179 million gallons saved for make-up water

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

Sound pr. (db(a)) Phone: Pressure hpa Fax: Capacity kw

A Selection Guide for DTL Series Heat Exchangers

Direct steam injection humidifiers

XI / PHYSICS FLUIDS IN MOTION 11/PA

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Gas Chromatography Liner Selection Guide

Optimize Thermal & Mechanical Design for Shell & Tube Heat Exchangers

FLUID FLOW Introduction General Description

Power consumption (kw)

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

In-Line Air Separators

PFT Two stage axial fan The high pressure fan for modern boiler plants

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

Experiment (13): Flow channel

E/M Experiment: Electrons in a Magnetic Field.

AdSORPTION CHILLER NAK

FLUID MECHANICS. TUTORIAL No.7 FLUID FORCES. When you have completed this tutorial you should be able to. Solve forces due to pressure difference.

Heat Exchangers. Heat Exchanger Types. Heat Exchanger Types. Applied Heat Transfer Part Two. Topics of This chapter

CHAPTER 8 UPGRADING EXISTING TREATMENT FACILITIES

Domino VGS. Domino. Vertical Gravity Separator VGS. Oil Out. Clean Water Outlet. Oily Water In. Sludge Outlet. Everything Water PTY LTD

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Development of High-Speed High-Precision Cooling Plate

REHABILITATION METHOD FOR INCREASING FLOW VELOCITY AND REDUCING SEDIMENTATION

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Solar Thermal Energy Storage Technologies

Lecture 24 Flumes & Channel Transitions. I. General Characteristics of Flumes. Flumes are often used:

Equipment for Engineering Education

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Butt Fusion Welding of HDPE Pipes Work Procedure

PUMP VIBRATION STANDARDS GUIDELINES

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

BRAZED PLATE INSTALLATION MANUAL

Solid shape molding is not desired in injection molding due to following reasons.

ThermoStar Refrigeration Air Dryers

Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace

INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS. Throughout this note he means he/she and his means his/hers.

Description of Thermal Oxidizers

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Thermal processing for drying, heating and cooling

C B A T 3 T 2 T What is the magnitude of the force T 1? A) 37.5 N B) 75.0 N C) 113 N D) 157 N E) 192 N

Design and Cost Optimization of Plate Heat Exchanger

16. Heat Pipes in Electronics Cooling (2)

STEAM TURBINE 1 CONTENT. Chapter Description Page. V. Steam Process in Steam Turbine 6. VI. Exhaust Steam Conditions, Extraction and Admission 7

Copa Raked Bar Screen

Routinely surveying tower overhead vacuum systems can

Weather Resistant Louvres

Transcription:

Case Study Involving Severely Fouling Heat Transfer: Design and Operating Experience of a Self-Cleaning Fluidized Bed Heat Exchanger and its Comparison with the Newly Developed Compact Self-Cleaning Fluidized Bed Heat Exchanger with EM Baffles Dr.Ir. Ing. Dick G. Klaren and Ing. Eric F. de Boer KLAREN BV, Hillegom, the Netherlands Presented at the Fachveranstaltung: Verminderung der Ablagerungsbildung an Wärmeübertragerflächen 4.-5. Oktober, 2004, Gartenhotel Heusser, Bad Dürkheim Copyright KLAREN BV September, 2004 Unpublished KLAREN BV, HILLEGOM, THE NETHERLANDS Tel.: (31) 252 530606; Fax.: (31) 252 530605; E-mail: info@klarenbv.com Internet: www.klarenbv.com

Case Study Involving Severely Fouling Heat Transfer: Design and Operating Experience of a Self-Cleaning Fluidized Bed Heat Exchanger and its Comparison with the Newly Developed Compact Self-Cleaning Fluidized Bed Heat Exchanger with EM baffles Dr.Ir. Dick G. Klaren and Ing. Eric F. de Boer KLAREN BV, Hillegom, the Netherlands Introduction. The self-cleaning heat exchange technology applying a fluidized bed of particles through the tubes of a vertical shell and tube exchanger was developed in the early 70s for sea desalination service. Since that time, several generations of technological advancements have made the modern self-cleaning heat exchanger the best solution for most severely fouling liquids. The reference listed at the end of this article gives an excellent review what happened in fluidized bed heat transfer over the past 30 years. In 1998 four large self-cleaning fluidized bed shell and tube heat exchangers were put into operation at a chemical plant in the USA in a severely fouling service. Their excellent performance in comparison with what could be achieved with severely fouling conventional shell and tube heat exchangers surprised the heat exchange community. However, we expect even more surprise if we explain the design and advantages of the newly developed and highly innovative compact self-cleaning fluidized bed heat exchangers for the same severely fouling service equipped with EM baffles in the shell. Principle of Self-Cleaning Heat Exchanger. In the following text of this presentation, we prefer to shorten expressions and leave out the term fluidized bed if we refer to self-cleaning heat exchangers and compact self-cleaning heat exchangers employing a fluidized bed. The principle of operation is shown in figure 1. The fouling liquid is fed upward through a vertical shell and tube exchanger which has specially designed inlet and outlet channels. Solid particles are also fed at the inlet where an internal flow distribution system provides a uniform distribution of the liquid and suspended particles throughout the internal surface of the bundle. The particles are carried through the tubes by the upward flow of liquid where they impart a mild scraping effect on the heat exchange tubes, thereby removing any deposit at an early stage of formation. These particles can be cut metal wire, glass or ceramic balls with diameters varying from 1 to 4 mm. At the top, within the separator connected to the outlet channel, the particles disengage from the liquid and are returned to the inlet channel through a downcomer and the cycle is repeated. Figure 2 shows an improved configuration where a new type of separator is used which does not apply centrifugal separation and, therefore, requires less pressure drop and does not experience any wear. 2

Outlet channel Inlet 3 Heat exchanger 2 Separator (cyclone) Support Outlet fouling liquid Outlet channel Inlet 3 Heat exchanger Liquid + particles 2 KLAREN separator Liquid Particles Outlet fouling liquid Support 1A = Main flow 1B = Control flow Particles Downcomer 1A 1B = Main flow = Control flow Downcomer Outlet 4 Liquid + cleaning solids Outlet 4 Liquid + cleaning solids Control channel Control channel Inlet channel with distribution system 1A 1B 1 Inlet fouling liquid Inlet channel with distribution sytem 1A 1B 1 Inlet fouling liquid Figure 1: Principle of self-cleaning heat exchanger with cyclone. Figure 2: Principle of self-cleaning heat exchanger with KLAREN separator. For both configurations, the process liquid fed to the exchanger is divided into a main flow and a control flow that sweeps the particles into the exchanger. By varying the control flow, it is now possible to control the amount of particles in the tubes. This provides control of aggressiveness of the cleaning mechanism. It allows the particle circulation to be either continuous or intermittent. Example of Severely Fouling Service and Solution of the Problem. A chemical plant in the United States cooled large quench flows from a proprietary process in open cooling towers. This quench released volatile organic compounds (VOCs) into the atmosphere. As a consequence of environmental regulations the quench cycle had to be closed by installing heat exchangers between the quench and the cooling from the cooling towers. Figure 3 gives a simplified flow diagram of the proposed installation consisting of two process lines and equipped with shell and tube heat exchangers. An experiment with a small conventional shell and tube test exchanger indicated that the proprietary process liquid would cause very severe fouling in the tubes. The results of this test 3

are shown in figure 4. In anticipation of this expected fouling, a well-known engineering company designed the system as shown in figure 5. Each process line was designed for a capacity of 3 x 50% = 150% with 2 x 50% in operation and the remaining 50% as spare for cleaning. This design would require 24 heat exchangers with 1,000 surface for each heat exchanger. As an alternative for this very expensive design, plant management decided to look into the possibility of using selfcleaning shell and tube heat exchangers. However, this required a test with a small self-cleaning heat exchanger. The results of this test in comparison with the results of the earlier test for the conventional configuration are also shown in figure 4 and justified the decision by plant management in favor of the self-cleaning design. 8400 m³/h 32 C HEX's Process line nr. 1 To process Pump Fouling process HEX's Process line nr. 2 Pump 8400 m³/h 46 C Figure 6 shows the self-cleaning design. Each process line was now designed for a capacity of 2 x 50% = 100%. Spare capacity was not considered necessary by plant management, which reflects their confi-dence in the self-cleaning design after they had seen the results of the test with the small self-cleaning exchanger. Figure 7 gives an impression of the dimensions of a self-cleaning heat exchanger and figure 8 shows the real installation with the four parallel selfcleaning heat exchangers at the plant site. The advantages of the self-cleaning heat exchanger in comparison with the conventional shell and tube exchanger for this severely fouling service go even much further than zero-fouling and the much smaller heat transfer surface to be installed. Figure 3: Figure 4: Simplified flow diagram of installation. Test results conventional and selfcleaning heat exchanger. 4

Pumping power for both production lanes: P = 2,740 kw To process Number of cleanings per year: Shell-side : 1 Tube-side : 10 to 12 8400 m³/h 32 C Shell and tube heat exchangers Shell and tube heat exchangers 50% 50% 50% 50% 50% 50% Figure 5: Pump process line nr.1 Conventional solution. 100% 100% Fouling process Pump process line nr. 2 8400 m³/h 46 C Pumping power for both production lanes: P = 816 kw To process Number of cleanings per year: Shell-side : 1 Tube-side : 0! 8400 m³/h 32 C Self-cleaning heat exchangers 1150 1150 1150 1150 50% 50% 50% 50% Figure 6: Pump process line nr.1 Self-cleaning solution. 100% 100% Fouling process Pump process line nr. 2 8400 m³/h 46 C 5

Table 1 presents a more detailed comparison between both types of heat exchangers each handling 50% of the flow of one of the process lines. Conventional Self-cleaning Flow tube-side (m³/h) 700 700 Flow shell-side (m³/h) 2,100 2,100 Total number of heat exchangers in series 4 1 Specifications per heat exchanger Total number of tubes 1,663 704 Tube diameter (mm) 19.05 x 1.65 31.75 x 1.65 Tube pitch (mm) 24.0 40.0 Tube length (mm) 12,000 16,000 Number of passes tube-side 3 1 Number of passes shell-side 1 1 Baffle type segmented cross segmented cross Baffle pitch (mm) 550 550 Diameter shell (mm) 1,300 1,350 Installed heat exchange surface () 1,000 1,122 Liquid velocity in tubes (m/s) 1.8 0.45 Particle size (mm) not applicable 1.6 Bed porosity in tube (%) not applicable 91 Total weight of particles (kg) not applicable 9,000 Clean k-value (W//K) 2,400 1) 2,500 2) Design k-value (W//K) 500 1) 1,800 2) Pressure drop clean tube-side (bar) 0.84 1) 2.2 Pressure drop clean shell-side (bar) 1.8 1) 2.4 Operating times between tube-side cleanings in weeks 4 to 5 larger than 120 1) Drop in k-value and increase in pressure drop due to fouling tubes takes place in 4 to 5 weeks 2) Differences between k-value determined by preferred overdesign not due to fouling Table 1: Comparison significant parameters conventional vs. self-cleaning heat exchangers. A typical and unique characteristic of the self-cleaning heat exchanger is the low liquid velocity in the tubes in comparison with the conventional exchanger. Even in spite of this low velocity the self-cleaning heat exchanger has an excellent clean k-value, which remains high in spite of the very severe fouling behavior of the liquid. As we ran into a couple of uncertainties with the self-cleaning heat exchanger and preferred an excellent reference installation, we installed some more surface than strictly required, which explains the lower design k-value in comparison with the clean k-value. This overdesign had nothing to do with fouling and even after very long operating periods the self-cleaning heat exchangers performed close to their clean k-value and the first inspection after 30 months of continuous operation showed shiny tubes. At the shell-side, we experienced very little fouling, which, because of the biological nature, could easily be controlled on line by an intermittent chemical treatment of the cooling. 6

Top view All dimensions in mm! 2100 m³/h 32 C 2100 m³/h 46 C Outlet channel 17,800 1,200 16,000 600 3 4 D PI 20 FI 3 N3 TI 3 TI 4 N4 Filling particles 20 Support Heat exchanger Ø 1175 FI 22 21 N2 22 TI 2 2 Ø 1,200 To process process liquid 700 m³/h Separator (cyclone) Solids Downcomer Ø 250 Vibrators Ø 300 Control channel 500 3,000 Discharge solids Inlet channel with distribution system 1A N1A VA-1B 1B N1B VA-1 FI 1 TI 1 1 Fouling process liquid 700 m³/h Figure 7: Design self-cleaning heat exchanger. Figure 8: 4,600 self-cleaning heat exchanger surface replacing 24,000 conventional surface. 7

The design of the conventional and self-cleaning exchangers was very much influenced by the potential vibration problem of the tubes in the shell. At the time of the design of this installation, we decided to control the tube vibration problem by installing segmented cross baffles in the shell. Table 2 compares both complete installations consisting of two parallel process lines and the advantages of the self-cleaning heat exchange configuration do not need any further explanation. However, we would like to draw attention to the large pumping power required for the conventional exchangers. This is caused by the pressure drop and the four shells in series, which (4 x 12 m = 48 m) are 3 times longer than the single shell of the self-cleaning exchanger (1 x 16 m = 16 m). Evidently, this factor 3 also applies for the design value of the shell-side pressure drop. Conventional Self-cleaning Total number of heat exchangers 24 4 Total installed heat transfer surface () 24 x 1,000 = 24,000 4 x 1,150 = 4,600 Total required pumping power for tube-side based on design conditions (kw) Total required pumping power for shellside based on design conditions (kw) 868 192 1,872 624 Total required pumping power (kw) 2,740 816 Time between tube-side cleanings in weeks 5 larger than 120 Table 2: Comparison significant parameters conventional vs. self-cleaning installation. What we actually have accomplished with the self-cleaning heat exchanger is a rather unique achievement in heat transfer: Excellent heat transfer without fouling, in spite of low velocities of the fouling liquid in the tubes, and requiring very little pressure drop and pumping power. As far as we know, there is no other heat exchange mechanism which combines these unique and, to a certain extent, contradictory characteristics. The Compact Self-Cleaning Heat Exchanger with EM baffles Although, we have shown that the self-cleaning heat exchanger performs excellently in a severely fouling service in comparison with conventional shell and tube exchangers, we can do even better. Therefore, we have to introduce the compact self-cleaning heat exchange technology in combination with the so-called EM baffles in the shell. The compact self-cleaning heat exchanger For 30 years, it was considered impossible to apply the self-cleaning fluidized bed heat exchange principle in tubes with an inner diameter D i smaller than 30 mm and in combination 8

with chopped metal wire cleaning particles with a diameter d p of 2 mm. Or said otherwise: For a satisfactory operation of a self-cleaning heat exchanger employing chopped metal wire particles of 2 mm, it was generally recommended to use tubes with an inner diameter of at least 30 mm and maintain a ratio Di / dp larger than 15. Until foreign researchers made a revolutionary discovery and demonstrated the feasibility of the self-cleaning principle in a single tube with an inner diameter of only 9.7 mm using chopped metal wire particles with a diameter of 2 mm, i.e. D i / d p < 5. We (KLAREN engineers) have found the design rules to make this unique discovery also workable in bundles with many parallel tubes. The consequences of this new development are that self-cleaning heat exchangers can now be designed with the following characteristics: Small hydraulic diameter, thin tube wall, high degree of turbulence, low liquid velocities, excellent film coefficients for heat transfer. These characteristics result in very compact self-cleaning heat exchangers and, particularly, a drastic reduction of the height of the self-cleaning heat exchanger. The EM baffle Shell Global Solutions International BV developed a new type of baffle for shell and tube heat exchangers. This new and really innovative tube support technology is based on Expanded Metal (EM) and an example is shown in figure 9. Expanded metal is a rigid piece of cold rolled metal that has been slit and expanded. In the expansion process, the metal length can be expanded up to ten times its original size. The exchanger can be designed as a longitudinal or crossflow exchanger on the shell side with one or more passes for the tube side. The EM baffle combines the advantages of other non-segmental (rod-baffle) heat exchanger types, such as less pressure drop, excellent heat transfer, reduction of fouling and no vibrations. These baffles can be fabricated at low cost. Many EM baffles in series create a static mixing effect of the liquid in the shell between the tubes which explains its excellent performance in heat transfer. Figure 9: Expanded metal in EM baffle. 9

The combination of compact self-cleaning cleaning heat exchanger and EM baffles Figure 10 shows the self-cleaning heat exchanger with a longitudinal flow and EM baffles in the shell. Table 3 compares the four self-cleaning designs three of which are compact and provided with EM baffles. For comparison, all exchangers are overdesigned by the same factor 1.38, but again, it should be emphasized that this difference between clean k-value and design k-value was not inspired by fouling. As we did not experience serious fouling at the shell-side, and in case of fouling could solve the problem with chemicals, the bundle was not removable from the shell and the minimum distance between the tubes could be made very small, determined by the minimum allowable tube pitch. This, of course, also contributes to the compact design. Self-cleaning Self-cleaning Self-cleaning Self-cleaning compact #1 compact #2 compact #3 Total number of tubes 704 1639 1981 4057 Tube diameter (mm) 31.75 x 1.65 19.05 x 1.65 15.88 x 1.21 12.70 x 0.90 Tube pitch (mm) 40 24 20 16 Minimum distance between tubes (mm) 8,25 4,95 4,12 3.30 Tube length (mm) 16,000 9,700 8,700 5,100 Number of passes tube-side / shell-side 1 1 1 1 Baffle type segmented cross EM EM EM Baffle pitch (mm) 550 unknown unknown unknown Diameter shell (mm) 1,350 1,065 970 1,110 Installed heat exchange surface () 1,150 951 833 824 Liquid velocity in the tubes (m/s) 0.45 0.6 0.7 0.5 Particle size (mm) 1.6 2.5 2.5 1.6 Bed porosity (%) 91 91 91 91 Total weight of particles (kg) 9,000 5,700 5,000 3,900 Clean k-value (W//K) 2,500 1) 3,300 1) 3,900 1) 3,900 1) Design k-value (W//K) 1,800 1) 2,391 1) 2,826 1) 2,826 1) Overdimensioning factor 1,38 1.38 1.38 1.38 Pressure drop tube-side (bar) 2.2 1.3 1.2 1.0 Pressure drop shell-side (bar) 2.4 1.2 1.2 0.6 Total required pumping power tube-side (kw) Total required pumping power shell-side (kw) 48 29 26 22 156 78 78 39 Total required pumping power tube + shell-side (kw) 1) Differences k-value by overdesign not due to fouling 204 107 107 61 Table 3: Comparison significant parameters self-cleaning vs. compact self-cleaning heat exchanger. 10

Overall comparison Table 4 highlights and summarizes the important differences between the various designs for the complete installation handling 4 x 700 m³/h process flow. In our earlier comparisons, we have seen that the conventional and self-cleaning heat exchangers are equipped with segmented cross baffles and not with EM baffles. For a fair comparison, this table also shows what differences in shell-side pressure drop and pumping power could be expected, if these exchangers would have been provided with EM baffles. However, there still remains some imbalance in this comparison: For the self-cleaning design, it is an advantage to create a film coefficient as high as possible at the shell-side, even at the expense of some more shell-side pressure drop by installing more EM baffles. For the conventional design, the very severe tube-side fouling limits the gain in overall heat transfer which can be achieved by installing many EM baffles and improving the shell-side film coefficient. How far we can go in limiting the number of EM baffles and shellside pressure drop without increasing the negative effects of shell-side fouling can only be determined by experiments. Conventional Selfcleaning Selfcleaning compact #1 Selfcleaning compact #2 Selfcleaning compact #3 Total number of heat exchangers 24 4 4 4 4 Total installed heat transfer surface () 24 x 1,000 = 24,000 4 x 1,150 = 4,600 4 x 951 = 3,804 4x 833 = 3,332 4 x 824 = 3,296 Total required pumping power for tube-side based on design conditions (kw) Total required pumping power for shell-side based on design conditions and segmented cross baffles (kw) Total required pumping power for shell-side based on design conditions and EM baffles (kw) 868 192 116 104 88 1,872 624 - - - 1,248 416 312 312 156 Total required pumping power with EM baffles in shell-side (kw) 868 + 1,248 = 2,116 192 + 416 = 608 428 416 244 Volumetric power factor (MW/m³) 0.37 1.52 4.22 5.45 7.10 Time between tube-side cleanings in weeks 5 >120 >120 >120 >120 Table 4: Important differences between the various designs. A newly introduced but also interesting parameter for comparison of the various designs for a particular application is the total heat transferred (i.e. also power) in MW divided by the volume of all heat exchanger shells, including the spares, in m³ and referred to in this publication as the Volumetric power factor. This factor is an indication for the 11

compactness of the total installed heat transfer surface in the total number of shells of the installation. Table 4 presents this factor for the various designs and the compact self-cleaning heat exchanger is an excellent tool to transfer many megawatts in a small shell volume. It would be worthwhile to compare the achievements of the compact self-cleaning shell and tube heat exchanger with plate heat exchangers. Conclusions 20 We believe that in a very convincing manner we have shown how the already superior self-cleaning heat exchange design of 1998 can be further improved by a compact selfcleaning design in combination with EM baffles at the shell-side. The results presented in Table 4 are a revelation in shell and tube heat transfer and have never been achieved before. We expect that these excellent results will accelerate the acceptance and penetration of self-cleaning heat exchangers in the market. Tube length Outlet channel 3 EM Baffle Shell diameter 22 KLAREN separator 2 Discharge Aknowledgements Dr. Klaren expresses his appreciation for his discussions with the inventor of the EM baffle Technology, Ir. D.F. Mulder MSc. of Shell Global Solutions International in Amsterdam, the Netherlands. EM Baffle 4 21 Downcomer Control channel REFERENCE Klaren, D.G. and E.F. de Boer (2004); Synoptic of the History of Thirty Years of Developments and Achievements in Self- Cleaning Fluidized Bed Exchangers. Internal Report KBV Nr. 7, March. Inlet channel Feed 1 1A Figure 10: Self-cleaning fluidized bed heat exchanger with EM baffles. 1B 12