TANKJKT. Heat Transfer Calculations for Jacketed Tanks SCREEN SHOTS. Copyright By chemengsoftware.com
|
|
|
- Jemima Young
- 9 years ago
- Views:
Transcription
1 TANKJKT Heat Transfer Calculations for Jacketed Tanks SCREEN SHOTS Copyright 2015 By chemengsoftware.com Visit for further information and ordering
2 The following page shows the Data Input worksheet. Pop up comment boxes and dynamic prompts guide your data entry.
3 Heat Transfer in Jacketed Vessels Version 3 by Stephen M. Hall, PE Copyright 2015 All cells are locked except user-defined data; unlock sheet from Tools menu (no password required) VIEW-COMMENTS to see some additional explanations. Scroll down and to the right to enter data. Project Data To restore a saved calculation, select it from the drop-down box below, Temperature Conversion Prepared by xx Client xx then click the "Restore Saved Calculation" button Enter value to convert: Date xx W.O. xx 550 F = C Unit xx Calculate 270 C = F Area xx Customary US SI Equip No xx Vessel Data Jacket Fluid Data Vessel Fluid Data Calc Title or Description Garvin Example from Table 2 Orientation vertical vol to tangent Fluid name Name Water Total working volume liters 1,497 1,497 Inside diameter mm 1,200.0 Temperature at jacket inlet C 95.0 Bulk Temp C 22.0 Tangent-to-tangent mm 1,200.0 Use properties of water Heads Properties from data table: Material of construction Thermal Conductivity W/m- C Thermal Conductivity W/m- C Thickness mm Specific Heat Joules/kg- C 1,737.5 Specific Heat Joules/kg- C 4,183.9 Lining Density g/cm³ Density g/cm³ Thickness mm Viscosity Pa-s Pa-s Internal surface roughness mm Latent Heat of Vap N/A Outside surface roughness mm Prandtl Number dimensionless 45.9 Internal fouling factor m²- C/W Vapor Pressure kpa abs Outside fouling factor (jacket) m²- C/W at inlet 2.64 Tank is Baffled at wall 0.30 Note: k, Cp and density assumed constant at all temperatures at outlet 1.05 Viscosity is adjusted, but better to enter 3 values below and check box Side-Wall Jacket Flow Rate in Side-Wall Jacket Agitator Data No Jacket Conventional Enter a value for each heat transfer surface. When one parameter is entered (flow, Impeller Type velocity, or pressure drop) the other two are calculated. Red value shows user entry. Half-Pipe Coil Dimple Total Flow Velocity Pressure Drop Impeller Diameter mm Inlet/Outlet Nozzle Size DN Sidewall Jacket liters/min 3.0 m/s 8.8 kpa Blade Height mm 72.0 Number of Zones 2 Bottom Jacket liters/min 2.0 m/s 2.3 kpa Blade Pitch (90 deg = upright) degrees 90 Portion of side-wall covered by jacket 1 Internal Coil Number of blades 6 Aiding flow (upflow during cooling/downflow during heating) Agitator Rotational Speed rpm 180 Page 1
4 g ( p g g/ g g) Half-Pipe Coil Jacket Data Quick Results Calculated tip speed meters/min Nominal Pipe Diameter DN Heat Transfer Coefficients Process Side HTF Side Overall U Cross section angle (180 or 120 deg) From Vessel to Sidewall Jacket 4,496 1, W/m²- C Spacing between Coils mm 25.0 From Vessel to Bottom Jacket 3, W/m²- C From Vessel to Coil Conventional Jacket Data Fluid Flow Flow Rate Velocity Pressure Drop Not Applicable Sidewall Jacket (each zone) liters/min 3.0 m/s 8.8 kpa Annular space dimension mm 40.0 Sidewall Jacket (combined) liters/min 3.0 m/s 8.8 kpa Standard Baffled Agit. Nozzles Bottom Jacket (in parallel with sidewall) liters/min 2.0 m/s 2.3 kpa Internal Coil Number of agitation nozzles per zone 2 Throat diameter for each nozzle mm Temperature Effects Inlet Outlet Heat Transferred 60.0 Sidewall Jacket C 137,909 W Bottom Jacket C 39,106 W Internal Coil Dimple Jacket Data Top Head -164 W Not Applicable Agitator Estimated power 0.4 kw Annular space dimension mm 20.0 x percent transferred as heat 35% 147 W Number of passes 1 Vessel Contents 22.0 W Center-to-center distance between adjacent dimples Vessel contents will heat at the rate of 1.70 C per minute Longitudinal mm Transverse mm Environmental Conditions Viscosity for Fluid inside the Vessel Mean dimple diameter mm 75.0 Air temperature C -5.0 Viscosity data at three temperatures Dimple pitch Triangular Square Wind speed m/s 2.0 Use this data Temp. Visc. Temp Bottom Head Jacket Tank insulation F cp K No Jacket Conventional Type Half-Pipe Coil Dimple Covering (on insulated surfaces) Same type as Side-Wall Jacket Viscosity coefficients #REF! (if uninsulated, enter "0" thickness) Thickness A B C Series Flow Sidewall mm , Bottom head mm 25.0 Temperature of interest 77 F Top head mm 0.0 Predicted viscosity 0.54 cp Internal Coil K No Coil Helical Hairpin Baffle or Harp Coil Use this section when you have experimental pressure drop data Input the known conditions Flowrate Viscosity Density Press Drop Use Experimental liter/min mpa-s g/cm³ kpa Pressure Drop Data Sidewall Sidewall 78.7 (one zone) 4 Bottom Head Bottom Head 2 See the instruction manual for further information about the use of this pressure drop technique Page 2
5 Two pre formatted reports are included. The first summarizes the input data, and presents the calculation results. The second includes a timeline, calculated using 60 time slices at a user defined interval. Because this is a spreadsheet, it s easy to customize the reports. Add your logo and address. The report formats complement chemengsoftware s other products such as PIPESIZE, VentManifold, and others.
6 JACKETED VESSEL HEAT TRANSFER CLIENT EQUIP. NO PAGE xx xx REV PREPARED BY DATE APPROVAL W.O. REQUISITION NO. SPECIFICATION NO. 0 xx xx xx 1 UNIT AREA PROCURED BY INSTALLED BY 2 xx xx Garvin Example from Table 2 1 Vessel Data 2 Orientation vertical, cylindrical Contents Water 3 Total working volume 1,497 liters Bulk Temperature 22 C 4 Inside diameter 1,200 mm Thermal Conductivity W/m- C 5 Tangent-to-tangent 1,200 mm Specific Heat 4,184 Joules/kg- C 6 Heads ASME Torispherical Dished Density g/cm³ 7 Material of construction 316 SS Pa-s 8 Thickness 7 mm 9 Lining Glass 10 Thickness mm 11 Internal surface roughness mm Agitator Type Turbine (Rushton) 12 Outside surface roughness mm Impeller Diameter 384 mm 13 Internal fouling factor m²- C/W Speed 180 rpm 14 Outside fouling factor (jacket) m²- C/W 15 Vessel is baffled 16 Jacket Fluid 17 Method for determining flow rate in jacket or coil: Fluid Name Syltherm Target Velocity Temperature at jacket in 95 C 19 Value 3 m/s Thermal Conductivity W/m- C 20 Pressure drop in sidewall determines flow in bottom jacket Specific Heat 1,725.8 Joules/kg- C 21 Syltherm 800 Density g/cm³ 22 Dow Chemical Co. Viscosity Pa-s 23 Polydimethyl-siloxane 24 Estimated vessel wall temp C Prandtl Number 46 dimensionless 25 Approx. max. vapor pressure kpa abs 26 Jacket and Coil Data 27 Sidewall Jacket Type Half-Pipe Coil Pipe size: 3 DN; 120 deg included angle; 25 mm between loops loops divided into 2 zones; 4 m2 total heat transfer area 29 Bottom Jacket Type Half-Pipe Coil Pipe size: 3 DN; 120 deg included angle; 25 mm between loops 30 1 m2 heat transfer area; piped in parallel with sidewall 31 Internal Coil Type No Coil Environmental: -5 C, 2 m/s; Sidewall, Bottom, Calcium Silicate insulation 34 Calculated Results 35 Heat Transfer Coefficients Process Side Wall HTF Side Overall U 36 From Vessel to Sidewall Jacket 4,496 1,181 1, W/m²- C 37 From Vessel to Bottom Jacket 3,469 1, W/m²- C 38 From Vessel to Coil 39 Pressure 40 Fluid Flow Flow Rate Velocity Drop 41 Sidewall Jacket (each zone) liters/min 3.0 m/s 8.8 kpa 42 Sidewall Jacket (combined) liters/min 3.0 m/s 8.8 kpa 43 Bottom Jacket (in parallel with sidewall) liters/min 2.0 m/s 2.3 kpa 44 Internal Coil 45 Temperature Effects Inlet Outlet Surface Heat Transferred 46 Sidewall Jacket C 13.0 C 137,909 W 47 Bottom Jacket C 13.0 C 39,106 W 48 Internal Coil 49 Top Hea C -164 W 50 Agitator 0kW x 35% 147 W 51 Vessel Contents 22.0 C 176,998 W 52 Vessel contents will heat at the rate of 1.7 degc per minute
7 JACKETED VESSEL HEAT TRANSFER CLIENT EQUIP. NO PAGE xx xx REV PREPARED BY DATE APPROVAL W.O. REQUISITION NO. SPECIFICATION NO. 0 xx xx xx 1 UNIT AREA PROCURED BY INSTALLED BY 2 xx xx Garvin Example from Table 2 1 Vessel Data 2 Orientation vertical, cylindrical Contents Water 3 Total working volume 1,497 liters Bulk Temperature 22 C 4 Inside diameter 1,200 mm Thermal Conductivity W/m- C 5 Tangent-to-tangent 1,200 mm Specific Heat 4,184 Joules/kg- C 6 Heads ASME Torispherical Dished Density g/cm³ 7 Material of construction 316 SS Pa-s 8 Thickness 7 mm 9 Lining Glass 10 Thickness mm 11 Internal surface roughness mm Agitator Type Turbine (Rushton) 12 Outside surface roughness mm Impeller Diameter 384 mm 13 Internal fouling factor m²- C/W Speed 180 rpm 14 Outside fouling factor (jacket) m²- C/W 15 Vessel is baffled 16 Jacket Fluid 17 Method for determining flow rate in jacket or coil: Fluid Name Syltherm Target Velocity Temperature at jacket in 95 C 19 Value 3 m/s Thermal Conductivity W/m- C 20 Specific Heat 1,725.8 Joules/kg- C 21 Pressure drop in sidewall determines flow in bottom jacket Density g/cm³ 22 Viscosity Pa-s Estimated vessel wall temp C Prandtl Number 45.9 dimensionless Jacket and Coil Data 27 Sidewall Jacket Type Half-Pipe Coil Pipe size: 3 DN; 120 deg included angle; 25 mm between loops loops divided into 2 zones; 4 m2 total heat transfer area 29 Bottom Jacket Type Half-Pipe Coil Pipe size: 3 DN; 120 deg included angle; 25 mm between loops 30 1 m2 heat transfer area; piped in parallel with sidewall 31 Internal Coil Type No Coil Environmental: -5 C, 2 m/s; Sidewall, Bottom, Calcium Silicate insulation 34 Timeline (calculated at 3-minute intervals) Time (minutes) 52 Temperature
8 Calculations are performed in open source Visual Basic for Applications (VBA) macros. The results are collected into an array that is output to a worksheet. This makes it easy to review the results without any clutter.
9 Heat Transfer in Jacketed Vessels Version 3 Result Details Sidewall Bottom Coil Top Head HTF Film Coefficient, ho 1, W/m2-C Process Film Coefficient, hi 4,496 3, W/m2-C Overall Coefficient, U W/m2-C Heat Transferred, Q 137,909 39, W HTF Flow Rate 17,511 5, kg/h HTF Pressure Drop kpa HTF Velocity m/s HTF Temperature In C HTF Temperature Out C HTF Temperature Average C HTF Temperature Wall C Process Temperature C Process Temperature Wall C Wall Coefficient, hw 1, , ,511.8 W/m2-C Agitator Power W Environmental film coefficient, he W/m2-C Jacket-to-environment Ue W/m2-C Jacket-to-environment Qe W Process-to-environment Ue 3.96 W/m2-C Process-to-environment Qe -164 W Surface Temperature C
International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No.161-166, March-April 2015
International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No.161-166, March-April 2015 http://www.mnkjournals.com/ijlrst.htm ISSN (Online):2278-5299 EXPERIMENTAL STUDY
Examples for Heat Exchanger Design
for Heat Exchanger Design Lauterbach Verfahrenstechnik GmbH 1 / 2011 Contents Calculation 1 1. Water- Water Heat Exchanger 1 Basics...1 Task...1 1. Start the WTS program...1 2. Selection of basic data...1
Window Glass Design 5 According to ASTM E 1300
A User s Guide to: Window Glass Design 5 According to ASTM E 1300 A product of: 1 Table of Contents Table of Contents List of Figures Chapter 1: Window Glass Design 5 1.1 Introduction 1.2 Features ii iv
Mixing in the process industry: Chemicals Food Pharmaceuticals Paper Polymers Minerals Environmental. Chemical Industry:
Mixing Notes: Chapter 19 Robert P. Hesketh Mixing in the process industry: Chemicals Food Pharmaceuticals Paper Polymers Minerals Environmental Chemical Industry: Paints and Coatings Synthetic Rubbers
SECTION 3: CLARIFICATION AND UTILITIES (1)
CHPR4402 Chemical Engineering Design Project The University of Western Australia SECTION 3: CLARIFICATION AND UTILITIES (1) Aaliyah Hoosenally 10428141 TEAM A: ALCOHOLICS ANONYMOUS AALIYAH HOOSENALLY,
Corrugated Tubular Heat Exchangers
Corrugated Tubular Heat Exchangers HEAT EXCHANGERS for the 21st CENTURY Corrugated Tubular Heat Exchangers (CTHE) Corrugated Tube Heat Exchangers are shell and tube heat exchangers which use corrugated
AN EFFECT OF GRID QUALITY ON THE RESULTS OF NUMERICAL SIMULATIONS OF THE FLUID FLOW FIELD IN AN AGITATED VESSEL
14 th European Conference on Mixing Warszawa, 10-13 September 2012 AN EFFECT OF GRID QUALITY ON THE RESULTS OF NUMERICAL SIMULATIONS OF THE FLUID FLOW FIELD IN AN AGITATED VESSEL Joanna Karcz, Lukasz Kacperski
Department of Chemical Engineering, National Institute of Technology, Tiruchirappalli 620 015, Tamil Nadu, India
Experimental Thermal and Fluid Science 32 (2007) 92 97 www.elsevier.com/locate/etfs Studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with right
HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS
HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS P.R.Hatwar 1, Bhojraj N. Kale 2 1, 2 Department of Mechanical Engineering Dr. Babasaheb Ambedkar College of Engineering & Research,
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
Understanding Plastics Engineering Calculations
Natti S. Rao Nick R. Schott Understanding Plastics Engineering Calculations Hands-on Examples and Case Studies Sample Pages from Chapters 4 and 6 ISBNs 978--56990-509-8-56990-509-6 HANSER Hanser Publishers,
STEAM TURBINE 1 CONTENT. Chapter Description Page. V. Steam Process in Steam Turbine 6. VI. Exhaust Steam Conditions, Extraction and Admission 7
STEAM TURBINE 1 CONTENT Chapter Description Page I Purpose 2 II Steam Turbine Types 2 2.1. Impulse Turbine 2 2.2. Reaction Turbine 2 III Steam Turbine Operating Range 2 3.1. Curtis 2 3.2. Rateau 2 3.3.
Battery Thermal Management System Design Modeling
Battery Thermal Management System Design Modeling Gi-Heon Kim, Ph.D Ahmad Pesaran, Ph.D ([email protected]) National Renewable Energy Laboratory, Golden, Colorado, U.S.A. EVS October -8, 8, 006 Yokohama,
CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER
International Journal of Advancements in Research & Technology, Volume 1, Issue2, July-2012 1 CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER ABSTRACT (1) Mr. Mainak Bhaumik M.E. (Thermal Engg.)
EXPERIMENTAL AND CFD ANALYSIS OF A SOLAR BASED COOKING UNIT
EXPERIMENTAL AND CFD ANALYSIS OF A SOLAR BASED COOKING UNIT I N T R O D U C T I O N Among the different energy end uses, energy for cooking is one of the basic and dominant end uses in developing countries.
Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger
Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger Nitesh B. Dahare Student, M.Tech (Heat power Engg.) Ballarpur Institute of Technology,
FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES
FREESTUDY HEAT TRANSFER TUTORIAL ADVANCED STUDIES This is the third tutorial in the series on heat transfer and covers some of the advanced theory of convection. The tutorials are designed to bring the
1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.
Sample Questions REVISED FIRST CLASS PARTS A1, A2, AND A3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations. They are not intended as study
Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29
_02 A centrifugal with a 12 in. diameter impeller requires a power input of 60 hp when the flowrate is 3200 gpm against a 60 ft head. The impeller is changed to one with a 10 in. diameter. Determine the
Fired Heater Design and Simulation
Fired Heater Design and Simulation Mahesh N. Jethva 1, C. G. Bhagchandani 2 1 M.E. Chemical Engineering Department, L.D. College of Engineering, Ahmedabad-380 015 2 Associate Professor, Chemical Engineering
Numerical Investigation of Heat Transfer Characteristics in A Square Duct with Internal RIBS
merical Investigation of Heat Transfer Characteristics in A Square Duct with Internal RIBS Abhilash Kumar 1, R. SaravanaSathiyaPrabhahar 2 Mepco Schlenk Engineering College, Sivakasi, Tamilnadu India 1,
PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
In-Line Air Separators
Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI
5.2. Vaporizers - Types and Usage
5.2. Vaporizers - Types and Usage 5.2.1. General Vaporizers are constructed in numerous designs and operated in many modes. Depending upon the service application the design, construction, inspection,
Test Report No. C1319LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Thermics S.r.l. Via dell'olmo
Test Report No. C908LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Changzhou He Jia Solar Energy
Test Report No. C926LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: AMK-Collectra AG Bahnweg Nord
Heat Transfer Analysis of Cylindrical Perforated Fins in Staggered Arrangement
International Journal of Innovative Technology and Exploring Engineering (IJITEE) ISSN: 2278-3075, Volume-2, Issue-5, April 203 Heat Transfer Analysis of Cylindrical Fins in Staggered Arrangement Amol
FLUID FLOW AND MIXING IN BIOREACTORS (Part 2 of 2)
FLUID FLOW AND MIXING IN BIOREACTORS (Part 2 of 2) Overview Power requirements for mixing Newtonian and non-newtonian liquids Ungassed and gassed systems Scale-up issues, scale-down approach Adapting bioreactor
Design,Development and Comparison of Double Pipe Heat Exchanger with Conventional and Annular Baffles
Design,Development and Comparison of Double Pipe Heat Exchanger with and Annular Baffles Mukund B Pandya Asst. Professor, Department of Mechanical Engineering, Babaria Institute of Technology, Varnama-
NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES
Vol. XX 2012 No. 4 28 34 J. ŠIMIČEK O. HUBOVÁ NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES Jozef ŠIMIČEK email: [email protected] Research field: Statics and Dynamics Fluids mechanics
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness
Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati
Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati Module No. # 04 Convective Heat Transfer Lecture No. # 03 Heat Transfer Correlation
Optimize Thermal & Mechanical Design for Shell & Tube Heat Exchangers
Optimize Thermal & Mechanical Design for Shell & Tube Heat Exchangers Webinar Q&A This document summarizes the responses to questions posed before and during the webinar on general Heat Exchanger Design
ECOplus Solar Cylinder
TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes
VAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22
BL_01 A thin flat plate 55 by 110 cm is immersed in a 6 m/s stream of SAE 10 oil at 20 C. Compute the total skin friction drag if the stream is parallel to (a) the long side and (b) the short side. D =
Machine Design II Prof. K.Gopinath & Prof. M.M.Mayuram. Module 2 - GEARS. Lecture 17 DESIGN OF GEARBOX
Module 2 - GEARS Lecture 17 DESIGN OF GEARBOX Contents 17.1 Commercial gearboxes 17.2 Gearbox design. 17.1 COMMERCIAL GEARBOXES Various commercial gearbox designs are depicted in Fig. 17.1 to 17.10. These
Light Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
Sound pr. (db(a)) Phone: +90 216 394 12 82 Pressure hpa 960.075. Fax: +90 216 394 12 87 Capacity kw 1200.000
Hybrid-Re-Cooler V-2x8 - Offer no. 1328 Sound power (db(a)) Sound pr. (db(a)) Company Schenkel & Partner GmbH 1 Branch Ingenieurbüro Street Bahnhofstrasse 44 Country/ZIP/City 8 Zürich Installation Credit
Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.
Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials. Attachment C1. SolidWorks-Specific FEM Tutorial 1... 2 Attachment C2. SolidWorks-Specific
Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 8, Issue 6 (Sep. - Oct. 2013), PP 25-29 Performance of the Boiler and To Improving the Boiler Efficiency
A TEST RIG FOR TESTING HIGH PRESSURE CENTRIFUGAL COMPRESSORS MODEL STAGES AT HIGH REYNOLDS NUMBER
A TEST RIG FOR TESTING HIGH PRESSURE CENTRIFUGAL COMPRESSORS MODEL STAGES AT HIGH REYNOLDS NUMBER P. NAVA, M.PROFETI, M. GIACHI, F.SARRI GE-NUOVO PIGNONE G.P.MANFRIDA UNIVERSITY OF FLORENCE Italia Presented
THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT
THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT Kazuto Otakane, Tokyo Gas Co., Ltd Katsuhito Sakai, Tokyo Gas Co., Ltd Minoru Seto, Tokyo Gas Co., Ltd 1. INTRODUCTION Tokyo Gas s new gas meter,
Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial
Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial facilities commonly occupy spaces with ceilings ranging between twenty and thirty feet in height.
Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description
Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed
globe reactions made easy Process perfection
globe reactions made easy Process perfection Benefits More reactions in less time: The Globe oil drain unit and quick clamp allow single hand vessel changes in seconds Space saving: 50ml, 100ml, 250ml,
Correlations for Convective Heat Transfer
In many cases it's convenient to have simple equations for estimation of heat transfer coefficients. Below is a collection of recommended correlations for single-phase convective flow in different geometries
Natural Convection. Buoyancy force
Natural Convection In natural convection, the fluid motion occurs by natural means such as buoyancy. Since the fluid velocity associated with natural convection is relatively low, the heat transfer coefficient
Desuperheater Online Program Sizing Guidance
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Chapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
Keywords: CFD, heat turbomachinery, Compound Lean Nozzle, Controlled Flow Nozzle, efficiency.
CALCULATION OF FLOW CHARACTERISTICS IN HEAT TURBOMACHINERY TURBINE STAGE WITH DIFFERENT THREE DIMENSIONAL SHAPE OF THE STATOR BLADE WITH ANSYS CFX SOFTWARE A. Yangyozov *, R. Willinger ** * Department
NEW IMPELLER DESIGN: ANTI-RAGGING IMPELLER, ARI2
14 th European Conference on Mixing Warszawa, 10-13 September 2012 NEW IMPELLER DESIGN: ANTI-RAGGING IMPELLER, ARI2 Robert Higbee a, Jason Giacomelli a, Wojciech Wyczalkowski a a Philadelphia Mixing Solutions,
MODEL TEG-F20. Specification Sheet. TEG-F20 Specification Sheet Ver. 2011-0310. Copyright(C) 2011 Tsukasa Sokken Co., Ltd.
Direct EGR Flow Meter MODEL TEG-F20 Specification Sheet TEG-F20 Specification Sheet Ver. 2011-0310 Copyright(C) 2011 Tsukasa Sokken Co., Ltd. 1. Overview Sokken model TEG series is an EGR Flow meter to
Enhancement of heat transfer of solar air heater roughened with circular transverse RIB
Enhancement of heat transfer of solar air heater roughened with circular transverse RIB Gurpreet Singh 1, Dr. G. S. Sidhu 2 Lala Lajpat Rai Institute of Engineering and Technology, Moga Punjab, India 1,2
How to make a line graph using Excel 2007
How to make a line graph using Excel 2007 Format your data sheet Make sure you have a title and each column of data has a title. If you are entering data by hand, use time or the independent variable in
Pump Formulas Imperial and SI Units
Pump Formulas Imperial and Pressure to Head H = head, ft P = pressure, psi H = head, m P = pressure, bar Mass Flow to Volumetric Flow ṁ = mass flow, lbm/h ρ = fluid density, lbm/ft 3 ṁ = mass flow, kg/h
Heat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts
Heat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts Imran Quazi#1, Prof. V.R.Mohite#2 #1DPCOE-Mechanical Department, SPP University Pune, India imranqu azi198 [email protected]
Test Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
VAD. Variable Area Desuperheaters
Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated
A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW. 1998 ASME Fluids Engineering Division Summer Meeting
TELEDYNE HASTINGS TECHNICAL PAPERS INSTRUMENTS A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW Proceedings of FEDSM 98: June -5, 998, Washington, DC FEDSM98 49 ABSTRACT The pressure
Direct Conversion of Wind Energy into Heat Using Joule Machine
International Conference on Environmental and Computer Science ICBEE vol.9() () IACSI ress, Singapore Direct Conversion of Wind Energy into Heat Using Joule Machine Roustiam Chakirov, and Yuriy Vagapov
SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
COMPUTATIONAL FLUID DYNAMICS (CFD) ANALYSIS OF INTERMEDIATE PRESSURE STEAM TURBINE
Research Paper ISSN 2278 0149 www.ijmerr.com Vol. 3, No. 4, October, 2014 2014 IJMERR. All Rights Reserved COMPUTATIONAL FLUID DYNAMICS (CFD) ANALYSIS OF INTERMEDIATE PRESSURE STEAM TURBINE Shivakumar
Technical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc. 1 Centrifugal Pump- Definition Centrifugal Pump can be defined as a mechanical device used to transfer liquid of various types. As
Power consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi
HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi 2 Rajesh Dudi 1 Scholar and 2 Assistant Professor,Department of Mechanical Engineering, OITM, Hisar (Haryana)
Heat Pipe Selection Revision 12/04/2001
Heat Pipe Selection Revision 12/04/2001 Heat pipes are being used very often in particular applications when conventional cooling methods are not suitable. Once the need for heat pipe arises, the most
Jump Start: Storage Tank Protection in Aspen HYSYS and Aspen Plus
Jump Start: Storage Tank Protection in Aspen HYSYS and Aspen Plus A Brief Tutorial (and supplement to training and online documentation) Anum Qassam, Product Management, Aspen Technology, Inc. Jennifer
HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems
HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems Fundamental Principles of Environmentally Responsible, Energy Efficient Buildings 1. Energy efficiency is
Lecture 24 - Surface tension, viscous flow, thermodynamics
Lecture 24 - Surface tension, viscous flow, thermodynamics Surface tension, surface energy The atoms at the surface of a solid or liquid are not happy. Their bonding is less ideal than the bonding of atoms
Performance Estimation of Water Thermal Energy Storage Tank by Using Simplified Simulation
Performance Estimation of Water Thermal Energy Storage Tank by Using Simplified Simulation M. Kubota, K. Sagara, T. Yamanaka, H. Kotani Division of Global Architecture, Graduate School of Engineering,
Transformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
Fiberstars Lighted Laminar Flow Fountain Installation Manual
Fiberstars Lighted Laminar Flow Fountain Installation Manual 79-15037-00 REV Xx http://www.fiberstars.com Page 1 of 8 SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation
Set up and solve a transient problem using the pressure-based solver and VOF model.
Tutorial 18. Using the VOF Model This tutorial was run using ANSYS FLUENT 12.1. The results have been updated to reflect the change in the default setting of node-based smoothing for the surface tension
Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.
Thermo 1 (MEP 261) Thermodynamics An Engineering Approach Yunus A. Cengel & Michael A. Boles 7 th Edition, McGraw-Hill Companies, ISBN-978-0-07-352932-5, 2008 Sheet 5:Chapter 5 5 1C Name four physical
ROLL PASS DESIGN EVAULUATION USING SOFTWARE APPLICATION ARINDAM MUKHERJEE PROJECT MANAGEMENT CELL UNDP/GEF PROJECT (STEEL)
ROLL PASS DESIGN EVAULUATION USING SOFTWARE APPLICATION ARINDAM MUKHERJEE PROJECT MANAGEMENT CELL UNDP/GEF PROJECT (STEEL) OBJECTIVE OF ROLL PASS DESIGN Steel sections are generally rolled in several passes,
16. Heat Pipes in Electronics Cooling (2)
16. Heat Pipes in Electronics Cooling (2) 16.1 Pulsating Heat Pipes 16.1.1Introduction Conventional heat pipe technology has been successfully applied in the last thirty years for the thermal management
NATIONAL RESEARCH COUNCIL CANADA. DIVISION OF BUILn ING RESEARCH DESIGN OF EXPOSED SEWER PIPES FOR INTERMITTENT USE UNDER FREEZING CONDITIONS
NATIONAL RESEARCH COUNCIL CANADA DIVISION OF BUILn ING RESEARCH DESIGN OF EXPOSED SEWER PIPES FOR INTERMITTENT USE UNDER FREEZING CONDITIONS D,G, by Stephenson Report No, 166 of the Division of Building
Experimental Study of Free Convection Heat Transfer From Array Of Vertical Tubes At Different Inclinations
Experimental Study of Free Convection Heat Transfer From Array Of Vertical Tubes At Different Inclinations A.Satyanarayana.Reddy 1, Suresh Akella 2, AMK. Prasad 3 1 Associate professor, Mechanical Engineering
ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Liquid Hydrogen Storage - Takuji Hanada, Kunihiro Takahashi
LIQUIDHYDROGEN STORAGE Takuji Hanada Air Liquide Japan Co., Ltd., Tokyo, Japan Kunihiro Center for Supply Control and Disaster Management, Tokyo Gas Co., Ltd., Tokyo, Japan Keywords: liquidhydrogen, insulation
Steady Flow: Laminar and Turbulent in an S-Bend
STAR-CCM+ User Guide 6663 Steady Flow: Laminar and Turbulent in an S-Bend This tutorial demonstrates the flow of an incompressible gas through an s-bend of constant diameter (2 cm), for both laminar and
CO 2 41.2 MPa (abs) 20 C
comp_02 A CO 2 cartridge is used to propel a small rocket cart. Compressed CO 2, stored at a pressure of 41.2 MPa (abs) and a temperature of 20 C, is expanded through a smoothly contoured converging nozzle
EAGLE ASSET TRACKING DATABASE
EAGLE ASSET TRACKING DATABASE Eagle Inspection Technologies offers a user friendly Asset Tracking Database designed specifically for small industrial facilities (Power Plants, Chemical Plants, Tank Farms,
International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: 0974-4290 Vol.7, No.6, pp 2580-2587, 2014-2015
International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: 0974-4290 Vol.7, No.6, pp 2580-2587, 2014-2015 Performance Analysis of Heat Transfer and Effectiveness on Laminar Flow with Effect of
Journal bearings/sliding bearings
Journal bearings/sliding bearings Operating conditions: Advantages: - Vibration damping, impact damping, noise damping - not sensitive for vibrations, low operating noise level - dust tight (if lubricated
CFD ANALYSES OF FLUID FLOW AND HEAT TRANSFER IN PATTERNED ROLL-BONDED ALUMINIUM PLATE RADIATORS
Third International Conference on CFD in the Minerals and Process Industries CSIRO, Melbourne, Australia 10-12 December 2003 CFD ANALYSES OF FLUID FLOW AND HEAT TRANSFER IN PATTERNED ROLL-BONDED ALUMINIUM
Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
Introduction to COMSOL. The Navier-Stokes Equations
Flow Between Parallel Plates Modified from the COMSOL ChE Library module rev 10/13/08 Modified by Robert P. Hesketh, Chemical Engineering, Rowan University Fall 2008 Introduction to COMSOL The following
CE 6303 MECHANICS OF FLUIDS L T P C QUESTION BANK PART - A
CE 6303 MECHANICS OF FLUIDS L T P C QUESTION BANK 3 0 0 3 UNIT I FLUID PROPERTIES AND FLUID STATICS PART - A 1. Define fluid and fluid mechanics. 2. Define real and ideal fluids. 3. Define mass density
Solar Hot Water Heaters
Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless
PAGE 2. Figure 1: Difference between PWL ins and SPL 1m
PAGE 1 Pipe noise J.H. Granneman and R.P.M. Jansen, Peutz Consulting Engineers, The Netherlands, emphasise the need for an adequate pipe noise control procedure, with reference to the design phase, insulation
(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark
Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 26 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES