Rack Mount Series Installation Guide

Similar documents
Video Surveillance UPS. Installation Guide

HM-W536 Install Guide

SECURITY / ACCESS / FIRE / SURVEILLANCE

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

AC-115 Compact Networked Single Door Controller. Installation and User Manual

INSTALLATION & SERVICE MANUAL. Display Panel

MCR1900 Media Converter 19-Slot Chassis

HP UPS R1500 Generation 3

Advantium 2 Plus Alarm

12-Volt 10-Amp Regulated Power Supply

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

FIREDEX Conventional Fire Panels

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Installation and Operation Guide PD4600 Series Converter Replacement

LOXONE 12 Channel Amplifier

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

PORTABLE ALARM CLOCK. Dual Alarm. FM Radio. Wake-up Sounds. USB Phone Charger G-1CR

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ST Series POWER SUPPLIES USER INSTRUCTIONS

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Water Leak Detection System

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

VLT Series 300 Watt True Sine Wave Inverter

Digital Keypad Use s Manual

Technical Update TAA.TU Rev. 1

Doorbell Intercom Security System

TS510 & TS500. Installation & User Guide. Compatible Equipment

Mobile Data Power Model: MDP-25

INSTALLATION INSTRUCTIONS

MIC-WKT and MIC-WKT-IR

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

DLP-PU/E Instruction Manual

Self Monitoring Power Supply (BPSM)

WE-350 Series ¼ Turn Electric Actuator

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

Single Day Alarm Clock with. Bluetooth and USB Play-through

Uninterruptible Power Supply

Contractors Guide Central Inverter System Installation

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

esata External Storage

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

EQUIPMENT SPECIFICATIONS

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

Alarm Security Kit - NVR

StorTrends 3400 Hardware Guide for Onsite Support

User s Manual Before using the inverter, you need to read and save the safety instructions.

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS

=============================== WARNING

12 Volt 30 Amp Digital Solar Charge Controller

AUTODIALLER / QUICKDIALLER - SA132

Installation Instructions

DAB+ / FM Tuner Model: TU-201

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Battery Power Inverters

UniStream CPU-for-Panel

GSM Autodialer Professional GJD700 Speech & Text Autodialer

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

DIGITAL ALARM CLOCK RADIO

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

TS93 EMR T/PT/TDE. Surface applied door closer

Secure Keypads for access control

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Manual for Fire Suppression & Methane Detection System

GSM Door Phone System

WD-AMX Water Detection Controllers

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Rack Mount LCD KVM Assembly Installer/User Guide

How To Use A Sata Dsa Hard Disk Storage System

DP-236Q Wireless Video Door Phone

Model 1756 Test Lead Kit

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Manual. Solar Fountain Mobile Phone Charger

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

HP R12000 and R18000 DirectFlow UPS User Guide

The Black Box Push Button Control Box

Transcription:

Rack Mount Series Installation Guide Models include: Maximal1RH Maximal1R - 12VDC @ 4 amp or 24VDC @ 3 amp. - 12VDC @ 4 amp or 24VDC @ 3 amp. - Eight (8) Fuse Protected Outputs. - Sixteen (16) Fuse Protected Outputs. Maximal3RH Maximal3R - 12VDC or 24VDC @ 6 amp. - 12VDC or 24VDC @ 6 amp. - Eight (8) Fuse Protected Outputs. - Sixteen (16) Fuse Protected Outputs. Maximal33R - 12VDC and/or 24VDC @ 12 amp. - Sixteen (16) Fuse Protected Outputs. Rev. 090109 More than just power. TM

Table of Contents: Maximal Rack Mount Series Overview... 3 Maximal Rack Mount Series Configuration Chart... 3 Maximal Rack Mount Series Specifications... 3 Installation Instructions... 4 Maintenance... 5 Fire Alarm Interface Switch Settings... 5 Output Voltage and Stand-by Specification Charts... 5 LED Diagnostics... 5 Power Supply Board Output Voltage Settings... 6 Fire Alarm Interface, Output Selection and Input Type... 6 Power Supply Board Drawings... 8 Hook-up Diagrams... 9 Mounting Bracket Diagrams... 10 Rack Mechanical Drawing and Dimensions... 11-2 - Maximal Rack Access Power Controllers (Fused)

Overview: Maximal Rack Mount Series units distribute and switch power to access control systems and accessories. They convert a 115VAC 50/60Hz input into eight (8) or sixteen (16) independently controlled 12VDC and/or 24VDC fuse protected outputs. Outputs are activated by an normally open (NO) or normally closed (NC) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail- Secure modes. The Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the outputs (see chart below). Maximal Rack Mount Series Configuration Chart: Altronix Model Number Maximal1RH Maximal1R Maximal3RH Power Supply 1 (8 outputs) Power Supply 2 (8 outputs) Total Output Current Fuse Protected Outputs 12VDC @ 4 amp N/A 4 amp 24VDC @ 3 amp N/A 3 amp 8 12VDC @ 4 amp N/A 4 amp 24VDC @ 3 amp N/A 3 amp 16 12VDC @ 6 amp N/A 24VDC @ 6 amp N/A 6 amp 8 Maximal3R 12VDC @ 6 amp N/A 6 amp 16 Maximal33R 12VDC @ 6 amp 24VDC @ 6 amp 12VDC @ 6 amp 12VDC @ 6 amp 24VDC @ 6 amp 24VDC @ 6 amp 12 amp 16 Maximum Current Per ACM8R-M Output 2.5 amp 2.5 amp 2.5 amp 2.5 amp 2.5 amp 115VAC 50/60Hz Input (current draw) Power Supply Board Input Fuse Rating 1.9 amp 5A/250V 1.9 amp 5A/250V 1.9 amp 3.5A/250V 1.9 amp 3.5A/250Vc 3.8 amp 3.5A/250Vc Inputs: Normally closed [NC] or normally open [NO] dry contact inputs (switch selectable). Outputs: Individually selectable Mag Lock/Strike (Fail-Safe, Fail-Secure) solid state fuse protected power outputs. Thermal and short circuit protection with auto reset. Fire Alarm Interface: Fire Alarm disconnect (latching with reset or non-latching) is individually selectable for any or all of the outputs. Remote reset capability for latching Fire Alarm Interface mode. Fire Alarm disconnect input options: a) Normally open [NO] or normally closed [NC] dry contact input. b) Polarity reversal input from signaling circuit. Visual Indicators: Individual Output Status LEDs located on the front panel. Specifications: Battery Backup: Built-in charger for sealed lead acid or gel type batteries (A separate enclosure is required for batteries). Maximum charge current.7 amp. Automatic switch over to stand-by battery when AC fails. Zero voltage drop when unit switches over to battery backup (AC failure condition). Supervision: AC fail supervision (form C contact). Low battery supervision (form C contact). Additional Features: Removable terminal blocks with locking screw flange. 3-wire line cord. Illuminated master power disconnect circuit breaker with manual reset. Rack Dimensions (H x W x D): 3.25 x 19.125 x 8.5 (82.55mm x 485.78mm x 215.9mm) Maximal Rack Access Power Controllers (Fused) - 3 -

Installation Instructions: Important: Adjust output voltages and Fire Alarm Interface configuration before installing unit in the rack. 1. Separate bottom and top of the rack mount chassis by removing six (6) screws (Rack Mechanical Drawing & Dimensions, pg. 11). CAUTI: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel. 2. Set output voltage: Select desired DC output voltage by setting SW1 on the power supply board(s) (Fig. 1a, pg. 6) to the appropriate position (Output Voltage and Stand-by Specification Charts, pg. 5). For Maximal33R: each set of eight (8) outputs can be set for 12VDC or 24VDC (example: eight (8) outputs @ 12VDC and eight (8) outputs @ 24VDC). 3. Input trigger programming options: The unit can be programmed to operate with either a normally open or normally closed input from access control devices by setting switches SW3 on either the ACM8R-S or ACM16R-S board to the appropriate position (Fig. 2b, pg. 7); OPEN for a normally closed [NC] trigger input or CLOSED for a normally open [NO] input. 4. Output programming options: a. The outputs can be programmed to be either all Fail-Safe (i.e. mag locks), all Fail-Secure (i.e. electric strikes) or any combination of each by setting the corresponding OUTPUT SELECT dip switches (1-8) on the ACM8R-S board to the appropriate position; for Fail-Safe outputs or OFF for Fail-Secure outputs (Fig. 2a, pg. 7). Note: the output configuration will follow the input trigger option b. To enable the Disconnect for an output the corresponding FIRE ALARM INTERFACE switch must be in the position. To disable the Disconnect the FIRE ALARM INTERFACE dip switches (1-8) on the ACM8R-S/ACM16R-S board must be in the OFF position (Fig. 2a, pg. 7). 5. Fire Alarm Interface hookup options: A normally closed [NC], normally open [NO] input or polarity reversal from an signaling circuit will trigger the selected outputs (Figs. 6-11, pg. 9). To program the Fire Alarm Interface set dip switches SW1 and SW2 on the ACM8R-M board to the appropriate positions (Figs. 3a & 3b, pg. 7) (Fire Alarm Interface Switch Settings pg. 5). 6. Battery Connections: For access control applications batteries are optional. If batteries are not used, a loss of AC will result in the loss of output voltage. When batteries are used, they must be lead acid or gel type. Connect one (1) battery to the terminals marked [-- BAT + ] for 12VDC operation. Use two (2) 12VDC batteries wired in series for 24VDC operation (Fig. 4b/5b, pg. 8). The rack mount enclosure will not accommodate batteries. A separate battery enclosure is required. Note: When using the Maximal33R with battery backup, two (2) separate batteries or sets of batteries must be used. 7. Battery and AC Supervision outputs: Connect the appropriate notification signaling device to the terminals marked AC Fail and Battery Fail on the power supply board(s) (Fig. 4a/5a, pg. 8). Use 22AWG to 18AWG for AC Fail and Low/No Battery reporting. 8. Reassemble the bottom and top of the rack mount chassis by fastening the six (6) screws. (Rack Mechanical Drawing & Dimensions pg. 11). 9. Attach mounting brackets to the rack mount Maximal for desired rack or wall installation (Fig. 12-14, pg. 10). 10. Mount in the desired rack location. Do not obstruct side air vents. 11. Set the power disconnect circuit breaker to the OFF position (Fig. 15a, pg. 11). 12. Plug power cord into a grounded 115VAC 50/60Hz receptacle (Fig. 15b, pg. 11). 13. Set the power disconnect circuit breaker to the position (Fig. 15a, pg. 11). 14. Measure the output voltage before connecting devices. This helps avoiding potential damage. 15. Set the power disconnect circuit breaker to the OFF position (Fig. 15a, pg. 11). 16. Input trigger connections: Connect the Normally Open or Normally Closed input triggers from the access control devices to the removable terminals marked [IN1 and ] through [ and ] for Maximal1RH and Maximal3RH. For Maximal1R, Maximal3R and Maximal33R connect devices to the second set of terminals. Make sure the devices match settings of SW3 in step 3 (Rack Mechanical Drawing & Dimensions pg. 11). 17. Output connections: Connect the devices to be powered to the removable terminals marked [-- OUT1 + to -- OUT8 +] for Maximal1RH and Maximal3RH. For Maximal1R, Maximal3R and Maximal33R connect devices to the second set of terminals marked [-- OUT1 + to -- OUT8 +] (Fig. 15c, pg. 11). 18. Fire Alarm Interface connection options: a. Connect the trigger input to the removable terminals marked 1 and 2. When using the polarity reversal from an signaling circuit, connect the negative [-] to the terminal marked 1 and the positive [+] to the terminal marked 2 (polarity is in alarm condition) (Rack Mechanical Drawing & Dimensions pg. 12). b. For a latching fire alarm interface connect a normally [NO] reset switch to the removable terminals marked [REST] and [] (Figs. 6-11, pg. 9). 19. Set the power disconnect circuit breaker to the position (Fig. 15a, pg. 11). - 4 - Maximal Rack Access Power Controllers (Fused)

Maintenance: Unit should be tested at least once a year for the proper operation as follows: Output Voltage Test: Under normal load conditions the DC output voltage should be checked for proper voltage level (Output Voltage and Stand-by Specification Charts, pg. 5). Battery Test: Under normal load conditions check that the battery is fully charged, check specified voltage at the battery terminals and at the board terminals marked [ BAT +] to ensure that there is no break in the battery connection wires. Fire Alarm Interface Switch Settings: Switch Position SW1 SW2 Input Open Open Signal Circuit (Polarity Reversal). Closed Closed Normally Closed [NC] Trigger Input. Closed Open Normally Open [NO] Trigger Input. Output Voltage and Stand-by Specification Charts: 20 Min. of 4 Hr. of 24 Hr. of Altronix Model Power Supply Board Battery Backup Backup Backup OLS120 12VDC/40AH* N/A 3.5 amp 0.5 amp Maximal1RH (Refer to Fig. 1a, pg. 4 for Switch [SW1] Maximal1R location and position) 24VDC/40AH* N/A 2.7 amp 0.7 amp Maximal3RH Maximal3R Maximal33R AL600ULXB (Refer to Fig. 1a, pg. 4 for Switch [SW1] location and position) LED Diagnostics: Power Supply Board LED Red (DC) Green (AC) Power Supply Status Normal operating condition. OFF Loss of AC, Stand-by battery supplying power. OFF No DC output. Short circuit or thermal overload condition. OFF OFF No DC output. Loss of AC. Discharged battery. Output LEDs on Front Panel Output is triggered. Blinking disconnect. 12VDC/40AH* N/A 5.5 amp 5.5 amp 24VDC/40AH* N/A 5.5 amp 0.7 amp Maximal Rack Access Power Controllers (Fused) - 5 -

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes. The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTI: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel. Power Supply Board Output Voltage Settings: Fig. 1 Maximal1RH, Maximal1R Power Supply Board OPEN - 24VDC CLOSED - 12VDC Fig. 1a SW1 Switch Detail OPEN SWITCH Maximal3RH, Maximal3R, Maximal33R Power Supply Boards OPEN - 24VDC CLOSED - 12VDC CLOSED SWITCH - 6 - Maximal Rack Access Power Controllers (Fused)

Fig. 2 Fire Alarm Interface, Output Selection and Input Type: Output Trigger LED s FIRE ALARM INTERFACE OUTPUT SELECT INPUT TYPE SW3 ACM8R-S Fig. 2a Fig. 2b SW3 SW3 Switch Detail OPEN SWITCH Dip Switches for & Output Programming Clip Switch for NO or NC Input CLOSED SWITCH Output Trigger LED s Output Trigger LED s INPUT TYPE SW3 FIRE ALARM INTERFACE OUTPUT SELECT FIRE ALARM INTERFACE OUTPUT SELECT INPUT TYPE SW3 Fig. 3 Fig. 3a Fig. 3b Fig. 3c SW1 Clip Switch for Selecting type of Input SW2 Clip Switch for Selecting type of Input FIRE ALARM ACM8R-M SW2 DC INPUT FIRE ALARM SW1 2 1 IN7 IN6 IN5 IN4 IN3 IN2 IN1 OUT8 OUT7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 ACM16R-S Maximal Rack Access Power Controllers (Fused) - 7 -

Power Supply Board Maximal1RH, Maximal1R Fig. 4 OPEN 24VDC CLOSED 12VDC Power Supply Board OFF AC DC 5A 250V L G N AC FAIL NC C NO NC C NO LOW BAT --- BAT - DC + Fig. 4a AC FAIL --- BAT + Battery and AC Supervision Built-in Battery Charging NC C NO NC C NO LOW BAT Fig. 4b --- BAT + Built-in Battery Charging Power Supply Board Maximal3RH, Maximal3R, Maximal33R Fig. 5 OPEN - 24V CLOSED - 12V Power Supply Board + DC --- + BAT --- AC DC BAT 5A 250V L G N BAT FAIL NC C NO NC C NO AC FAIL + BAT --- Fig. 5a BAT FAIL NC C NO NC C NO AC FAIL Battery and AC Supervision Built-in Battery Charging Fig. 5b Built-in Battery Charging - 8 - Maximal Rack Access Power Controllers (Fused)

Fig. 6 Hook-Up Diagrams Polarity Reversal Input from Signal Circuit Output (Polarity is referenced in alarm condition) Fig. 7 1 2 Fig. 8 1 2 -- + Factory Installed Jumper Non-Latching 5-30VDC from Signal Circuit Normally Closed [NC] Dry Trigger Input Factory Installed Jumper Non-Latching 1 2 Normally Closed Input from Fig. 9 1 2 Normally Open Input from Fig. 10 Fig. 11 -- + 5-30VDC from Signal Circuit Normally Open [NO] Reset Switch Latching Normally Closed [NC] Dry Trigger Input Normally Open [NO] Reset Switch Latching 1 2 Normally Open [NO] Dry Trigger Input 1 2 Normally Open [NO] Dry Trigger Input Factory Installed Jumper Normally Open [NO] Reset Switch Non-Latching Latching Maximal Rack Access Power Controllers (Fused) - 9 -

Fig. 12 Mounting Options: A Mounting Hardware (Included): Two (2) mounting brackets. Remove center brace from rack mount chassis before proceeding with installation. B C Eight (8) flat head screws for mounting brackets. Eight (8) pan head screws for faceplate. Rack Mount Installation 1. Remove center brace from rack mount chassis (Fig. 12, pg. 10). 2. Slide mounting brackets (A) into slots located on left and right side of rack enclosure (Fig. 13a). Use three (3) flat head screws (B) to secure brackets. 3. Carefully place faceplate over LED s, and secure using three (3) pan head screws (C) on top and three (3) pan head screws (C) on the bottom of faceplate (Fig. 13b, pg. 10). 4. Slide unit into desired EIA 19 rack position and secure with mounting screws (not included) (Fig. 13c, pg. 10). Fig. 13 Fig. 13a Fig. 13b Fig. 13c B A Wall Mount Installation 1. Carefully place faceplate over LED s, and secure using three (3) pan head screws (C) on top and three (3) pan head screws (C) on the bottom of faceplate (Fig. 14a). 2. Place mounting brackets (A) onto the side of the left and right side of rack enclosure (Fig. 14b). Use three (3) flat head screws (B) to secure mounting brackets. 3- Mount rack and secure with mounting screws (not included) (Fig. 14c). Fig. 14 Fig. 14a Fig. 14b Fig. 14c C A B C - 10 - Maximal Rack Access Power Controllers (Fused)

Fig. 15 Fig. 15a Fig. 15b Fig. 15c () Rack Mechanical Drawing & Dimensions 3.25 x 19.125 x 8.5 (82.55mm x 485.78mm x 215.9mm) 3-Wire Line Cord Removable Terminal Block Terminal Legend 2 1 IN7 IN6 IN5 IN4 IN3 IN2 IN1 Rear OUT8 OUT7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 3.125" 79.4mm 2 1 IN16 IN15 IN14 IN13 IN12 IN11 IN10 IN9 OUT16 OUT15 OUT14 OUT13 OUT12 OUT11 OUT10 OUT9 ( ) 2 1 IN7 IN6 IN5 IN4 IN3 IN2 IN1 OUT8 OUT7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 Bottom 17.625" 447.7mm 8.5" 215.9mm Front 0.75" 19.1mm 19.125" 485.8mm Maximal Rack Access Power Controllers (Fused) - 11 -

Notes: Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIMaximalRackMountSeries F30N MEMBER - 12 - Maximal Rack Access Power Controllers (Fused)