USER MANUAL AD 130 ph/mv/temperature Portable Meter

Similar documents
ExStik TM ph Waterproof Meters

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Milwaukee USER MANUAL

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Instruction Manual Temp 4/5/6 Temperature Meter Series

Care and use guide. Contents. a handy solution made easy. page

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

ph 200 ph-/redox-/temperature Meter Operating instructions

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Thermistor Thermometer MODEL NO

SenTix 950 SenTix 980

UltraBasic Benchtop ph Meter Operation Manual

Instruction Manual ph 5+ ph 6+ Ion 6+ Technology Made Easy...

Instruction Manual HI Refractometer for Sucrose Measurements

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Thermocouple Thermometer Models

Microwave Meter. Instruction Manual

Care and use guide. Contents. page

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

Care and use guide. Contents. a handy solution made easy. page

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Ground Resistance Clamp-On Tester

DISSOLVED OXYGEN METER Model : DO-5509

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Refer to page 6 to page 19 for detailed instructions.

Operating Instructions

Model 4510 Conductivity/TDS Meter Operating Manual

Ground Resistance Clamp On Tester

Portable Waterproof ph/dissolved Oxygen Meter

INSTRUCTION MANUAL DTH Fax: (503)

AIRMoN, ph and Conductivity Field Measurement

Bluelab Soil ph Meter Instruction Manual

ph Measurement and Control

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Instruction Manual DO 110. Hand-held Dissolved Oxygen Meter with RS 232C. 68X Rev. 0-11/05. Technology Made Easy...

OCS-S High Resolution Digital Crane Scale

Pro1030 USER MANUAL. English

Dual Laser InfraRed (IR) Thermometer

4-Channel Thermometer / Datalogger

Operating manual. ph ph meter. ba75791e02 11/2008

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Care and use guide. soil ph meter. Contents. page

PART 1 - INTRODUCTION...

RS DIGITAL THERMOMETER

USEPA Electrode Method Method 8156

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Wireless Indoor/ Outdoor Thermometer

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

COASTAL AMUSEMENTS INC.

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Relative Humidity Calibration Kit

Electrical Stability Tester, Model 23E Instruction Manual Manual No , Revision B Instrument No

DSM155 Digital LED Light Meter User s Manual DSM155

RT-1261A Ear and Forehead Thermometer Owner s Manual

Operating manual. ph 7310 ph 7310P. Printermodul. ph 7310P. ph ph meter

Dissolved Oxygen Sensors

Wolverine Data PASS Portable Scanner User Manual V1.0

BODY FAT & HYDRATION % MONITOR SCALE

Barnant Company THERMOCOUPLE THERMOMETER. Dual J-T-E-K MODEL NO Barnant Company

Hygro-Thermometer + InfraRed Thermometer Model RH101

User's Guide Integrating Sound Level Datalogger Model

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

Operating manual. ph/cond 3400i. Tref25 nlf C TP CAL. ph/conductivity measuring instrument. ba75687e01 01/2007

Thermocouple Thermometer

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

Instant Ear Thermometer

Operating manual. ph ph meter

Light Meter (Foot Candles)

Dual Laser InfraRed (IR) Thermometer with Color Alert

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Tympanic Thermometer

User's Guide. Pinless Moisture Meter. Model MO257

User Guide. Temperature and Humidity Datalogger. Model 42280

digital fever alert ear thermometer suitable from birth instruction manual

AM/FM PLL Clock/Table Radio

AutoRanging Digital MultiMeter

TC-9102 Series Surface Mount Temperature Controllers

Appendix C. Vernier Tutorial

Model 349KLX Remote Display Digital Scale User Instructions

Measurement by Ion Selective Electrodes

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

ph-meter 1140 and ph-meter 1140-X Instruction manual

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Global Water Instrumentation, Inc.

Dual Laser InfraRed (IR) Thermometer

DISSOLVED OXYGEN PROBE

WSD130 SOLDERING STATION

OPERATIONS MANUAL. ba76143e04 09/ MultiLab DIGITAL METER FOR IDS SENSORS

TIG INVERTER INSTRUCTION MANUAL

Operating instructions Platform/floor scales

Periodic Verification System Model 775PVS

MAINTENANCE & TROUBLESHOOTING

Transcription:

USER MANUAL AD 130 ph/mv/temperature Portable Meter www.adwainstruments.com

Dear Customer, Thank you for choosing an Adwa product. Please read carefully this manual before starting operations. This instrument is in compliance with the EMC directive 2004/108/EC and its standards, and Low Voltage Directive 2006/95/EC and its standards for electrical equipments. For additional technical information, please e-mail us at sales@adwainstruments.com. 2

TABLE OF CONTENTS Introduction... 4 Technical Data... 5 Front and Top Panels... 8 Operational Guide... 10 Hold and Memory Recall Functions... 16 ph Calibration... 17 Setup Menu... 23 Battery Replacement... 25 LCD Message Guide... 27 ph Electrode Conditioning & Maintenance... 29 Electrodes, Probes and Solutions... 31 Troubleshooting Guide... 32 Warranty... 34 3

INTRODUCTION AD130 is a heavy-duty portable ph meter designed to provide laboratory results and accuracy even under harsh industrial conditions. Main features include: 7 memorized buffers for ph calibration (ph 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) Messages on the LCD to make the calibration easy and accurate ph readings with manual or automatic temperature compensation ph calibration using ph buffers with 0.01 resolution Temperature range from -20 to 120 C (-4 to 248 F) using AD7662 probe AD130 can also use ORP electrodes to measure mv, with a resolution up to 0.1 mv. 4

AD130 is supplied complete with: AD1230B ph electrode with double ceramic junction, BNC connector and 1 m cable AD7662 stainless steel temperature probe, 1 m cable 1.5V AA alkaline batteries (4 pcs.) User manual 5

TECHNICAL DATA Range -2.00 to 16.00 ph ±1999 mv -20.0 to 120.0 C (-4.0 to 248.0 F) Resolution 0.01 ph 0.1 mv (±699.9 mv) / 1 mv (outside) 0.1 C (0.1 F) Accuracy ±0.01 ph (@25 C/77 F) ±0.2 mv up to ±699.9 mv ±1 mv (outside) ±0.4 C (±0.8 F) (excluding probe error) ph Calibration 1 or 2 point calibration, 7 standard buffers available (ph 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) Temperature Manual or automatic, Compensation -20.0 to 120.0 C (-4.0 to 248.0 F) ph Electrode Temperature Probe Input Impedance Battery Type Battery Life AD1230B AD7662 10 12 Ohm 4x1.5V AA size, alkaline Approx. 500 hours of continuous use 6

Auto-off User selectable: 20 minutes or disabled Environment Dimensions Weight 0 to 50 C (32 to 122 F) RH max. 95% 188 x 96 x 70 mm 460 g 7

FRONT AND TOP PANELS 8

1. Temperature probe socket 2. Liquid Crystal Display (LCD) 3. ON/OFF key, to turn the meter ON and OFF 4. HOLD/CLR key, to freeze reading on display and store it in the instrument memory, or to clear calibration 5. CFM/SETUP key, to confirm calibration or enter setup mode 6. MRCL key, to recall stored value 7. Up & Down arrow keys, for manual temperature setting, entering menu parameters or changing buffer value 8. CAL key, to enter/exit calibration mode 9. RANGE key, to select ph or mv reading 10. Secondary display 11. Primary display 12. BNC connector for ph or ORP electrodes 9

OPERATIONAL GUIDE The meter is supplied complete with four 1.5V AA alkaline batteries. Remove the cover, unwrap the batteries and install them while paying attention to their polarity (also see Battery Replacement section). To prepare the instrument for use, connect ph electrode and temperature probe to the BNC and temperature sockets on the top of the instrument. The temperature probe is used in conjunction with the ph electrode to utilize the meter s ATC capability, but it can also be used independently to take temperature measurements. If the probe is disconnected, the temperature can be set manually using the arrow keys (see page 13 for details). 10

INSTRUMENT START-UP Turn the instrument on by pressing ON/OFF. At start-up the display shows all the used segments for a few seconds (or while the button is held), followed by the percentage indication of the remaining battery charge, then enters the measurement mode. After measurement switch the meter off, clean the electrode and store it with a few drops of AD70300 storage solution in the tip protection bottle. To save battery life, the auto-off feature turns the meter off after 20 minutes with no button pressed. This feature can also be disabled (see Setup Menu section for details). 11

ph MEASUREMENTS Remove the electrode tip protection bottle. Submerge the ph electrode tip (4 cm) and the temperature probe into the sample to be tested. If necessary, press the RANGE key until the display changes to the ph mode. Allow for the electrode to adjust and reading to stabilize (hourglass symbol turns off). The LCD will show the ph measurement together with the temperature of the sample. In order to take more accurate ph measurements, make. sure that the instrument is calibrated (see ph Calibration section for details). 12

It is recommended to keep the ph electrode always wet and to rinse it thoroughly with some sample to be measured before use. The ph reading is directly affected by temperature. In order to measure the ph accurately, temperature must be taken into consideration. If the sample temperature is different from the temperature at which the ph electrode was kept, allow a few minutes to reach thermal equilibrium. To use the meter s automatic temperature compensation (ATC) capability, submerge the temperature probe into the sample as close to the electrode as possible and wait for a few minutes. If manual temperature compensation (MTC) is desired, the temperature probe must be disconnected. The display will show the default temperature of 25 C or the last set temperature together with the C (or F) indicator blinking. 13

The MTC tag and up & down arrow symbols light up on the LCD to indicate that the meter is in MTC mode. The arrow keys can be used to enter the desired temperature value. Note: In MTC mode, the user can press and hold the arrow keys to incrementing or decrementing quickly the temperature value. The meter will keep measuring and the display is updated every second. ORP MEASUREMENTS To perform ORP measurements, connect the ORP electrode (AD3230B, optional) to the meter and turn it on by pressing the ON/OFF button. If necessary, enter the ORP mode by pressing RANGE until the display changes to mv. Submerge the ORP electrode tip (4 cm) into the sample to be tested and wait a few minutes for the reading to stabilize. Measurements within the ±699.9 mv range are displayed with 0.1 mv resolution, while outside this range the resolution automatically switches to 1 mv. 14

Since mv readings are not temperature compensated, the ATC and MTC tags are turned off. For accurate ORP measurements, the surface of the electrode must be clean and smooth. Pretreatment solutions are available to condition the electrode and improve its response time (see Electrodes, Probes and Solutions section for details). Notes: When the reading is out of range, the closest full-scale value will blink on display. If using ph electrode while in mv mode, the meter will measure the mv generated by the ph electrode. 15

HOLD AND MEMORY RECALL FUNCTIONS From measurement mode, pressing the HOLD key will freeze the reading on display. The frozen value is also stored in the instrument memory and can be recalled at any time by pressing the MRCL key. The H symbol blinks to indicate that the display is in hold mode. Press the HOLD key again to return to normal operations. Notes: While in HOLD mode, the user can switch between ph and mv by pressing the RANGE key. The memorized value is displayed as long as the MRCL key is pressed, together with H and RCL symbols. When the key is released, the display returns to normal measurement mode. 16

ph CALIBRATION It is recommended to calibrate the instrument frequently, especially if high accuracy is required. The ph range should be recalibrated: a) Whenever the ph electrode is replaced b) At least once a week c) After testing aggressive chemicals d) When extreme accuracy is required PREPARATION The user can choose among 7 memorized buffers (ph 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45). Pour small quantities of selected buffer solutions into clean beakers. For accurate calibration use two beakers for each buffer solution, the first one for rinsing the electrode and the second one for calibration. Remove the tip protection bottle and rinse the electrode with some of the buffer solution to be used for the first calibration point. 17

TWO-POINT CALIBRATION Press the CAL key. CAL and BUFFER tags will be displayed. The secondary LCD will display the value 7.01 ph. If a different calibration buffer is desired, use the arrow keys to change the displayed value. 18

Submerge the electrode tip approximately 4 cm into the solution, place the temperature probe as close as possible to the electrode and stir gently. The message NOT READY will blink for 12 seconds. Then, if the reading is not close to the selected buffer, WRONG BUFFER and WRONG ELECTRODE will blink alternatively; if the reading is close to the selected buffer, the calibration is performed and the display will show READY and blinking CFM. 19

Press CFM to confirm the calibration and the meter will store the first calibration point. The primary LCD will show the calibrated reading, while the secondary LCD will show the second expected buffer (ph 4.01). If a different calibration buffer is desired, select the appropriate value with the arrow keys. After the first calibration point is confirmed, submerge the electrode tip approximately 4 cm into the second buffer solution, place the temperature probe as close as possible to the electrode and stir gently. The LCD will flash NOT READY for 12 seconds. Then, if the reading is not close to the selected buffer, WRONG BUFFER and WRONG ELECTRODE will blink alternatively; if it is close to the selected buffer, the calibration is performed and the display will show READY and blinking CFM. 20

Press the CFM key to confirm the second calibration point. The meter stores the calibration data and returns to normal measurement mode. The tags corresponding to the buffers used for calibration will light up. 21

Notes: To avoid erroneous procedures, the meter automatically skips the buffer used for the first calibration point. A difference of at least 1.5 ph units is required between the two buffers used for offset and slope calibration (i.e. once calibrated at either ph 7.01 or ph 6.86, the instrument automatically ignores the other value for the second point. Same for ph 10.01 and ph 9.18). During calibration, the secondary LCD shows the selected buffer value. Press RANGE to display the buffer temperature. To clear previous calibration and return to the default values, press the CLR key at any time after entering the calibration mode. The LCD will show the message CLr CAL for one second, and then will return to normal measurement mode. 22

ONE-POINT CALIBRATION For optimum accuracy it is always recommended to perform a two-point calibration, but for a faster operation it is also possible to carry out a single-point procedure. The meter can be calibrated using any of the memorized buffers, but the ph 7.01 or ph 6.86 value is normally the most appropriate for a single-point procedure. After calibrating the first point, press the CAL key to exit the calibration mode. SETUP MENU The instrument allows the user to configure the parameters through a setup menu. To enter the setup mode, from normal measurement mode press and hold the SETUP key for about 5 seconds. The value of each parameter can be changed by using the arrow keys and then confirmed with the CFM key. After setting and confirming a parameter, the meter will automatically show the next one. 23

This is the sequence of programmable parameters: 1. Auto-off feature: 20 minutes (default) or disabled. 2. Temperature measure unit: C (default) or F. After setting the last parameter, pressing the CFM key will confirm the value and return to normal measurement mode. 24

BATTERY REPLACEMENT If batteries become weak, the display will flash the battery symbol to advise the user that approximately 25 hours of working time are left. It is recommended to replace the batteries soon. Moreover, when the battery level is too low to ensure reliable readings, the meter automatically turns off. At start-up the display will show 0 batt for a few seconds and then the meter turns off. 25

Battery replacement must only take place in a safe area and using the battery type specified in this instruction manual. To replace rundown batteries, remove the battery cover and substitute all four 1.5V AA alkaline batteries with new ones, while paying attention to the correct polarity. Reattach and tighten the battery cover making sure that the gasket is in place. 26

LCD MESSAGE GUIDE MODE TAGS light up to indicate the corresponding active mode, and blink for warning the user. SETUP on: setup menu mode has been entered CFM blinking: ask confirmation of calibration point CAL on: calibration mode has been entered CAL blinking: meter is not calibrated or calibration is expired H symbol blinking: reading is frozen on display and memorized H symbol and RCL on: memorized value is displayed 27

TEMPERATURE COMPENSATION MODES: MTC: manual compensation ATC: automatic compensation BATTERY SYMBOL blinking: low battery condition. Batteries should be replaced soon. CALIBRATION MESSAGES: NOT READY blinking: buffer has been recognized, but reading is not stable READY on: buffer has been recognized and reading is stable WRONG BUFFER and WRONG ELECTRODE blinking alternatively: wrong buffer and electrode not recognized 28

ph ELECTRODE CONDITIONING & MAINTENANCE PREPARATION PROCEDURE Remove the electrode tip protection bottle. DO NOT BE ALARMED IF SALT DEPOSITS ARE PRESENT. This is normal with electrodes and they will disappear when rinsed with water. During transport, tiny bubbles of air may form inside the glass bulb. The electrode cannot function properly under these conditions. These bubbles can be removed by shaking down the electrode as you would do with a glass thermometer. If the bulb and/or junction are dry, soak the electrode in AD70300 storage solution for at least one hour. STORAGE PROCEDURE To minimize clogging and ensure a quick response time, the glass bulb and the junction should always be kept moist. When not in use, store the electrode with AD70300 storage solution in the tip protection bottle. NEVER USE DISTILLED OR DEIONIZED WATER TO STORE THE ELECTRODE. 29

PERIODIC MAINTENANCE Inspect electrode and cable. The cable used for connection to the meter must be intact and there must be no points of broken insulation on the cable or cracks on the electrode stem or bulb. If any scratches or cracks are present, replace the electrode. Rinse off any salt deposits with water. Connectors must be perfectly clean and dry. CLEANING PROCEDURE Soak the electrode tip in AD7061 cleaning solution for approximately 30 minutes. IMPORTANT: After performing a cleaning procedure, rinse the electrode thoroughly with distilled water and soak it in AD70300 storage solution for at least 1 hour before taking measurements. 30

ELECTRODES, PROBES AND SOLUTIONS AD1230B AD3230B AD7662 AD70004P AD7004 AD70007P AD7007 AD70010P AD7010 AD70300 AD7061 ph electrode with double ceramic junction, BNC connector and 1 m cable ORP electrode with single ceramic junction, BNC connector and 1 m cable Stainless steel temperature probe with 1 m cable. ph 4.01 buffer solution, 20 ml sachet, 25 pcs. ph 4.01 buffer solution, 230 ml bottle ph 7.01 buffer solution, 20 ml sachet, 25 pcs. ph 7.01 buffer solution, 230 ml bottle ph 10.01 buffer solution, 20 ml sachet, 25 pcs. ph 10.01 buffer solution, 230 ml bottle Electrode storage solution, 230 ml bottle Electrode cleaning solution, 230 ml bottle 31

TROUBLESHOOTING GUIDE SYMPTOM Slow response/ excessive drift. Reading fluctuate up and down (noise). The display shows blinking full scale value. mv scale out of range. PROBLEM Dirty ph electrode. Clogged/dirty junction. Reading out of range. Dry membrane or dry junction. Display shows Temperature probe blinking C or F. is not connected or out of order. SOLUTION Soak the electrode tip in AD 7061cleaning solution for 30 minutes and then follow the storage procedure. Clean the electrode. Check that sample is within measurable range. Check electrolyte level and general electrode status. Soak electrode in AD70300 storage solution for at least 30 minutes. Connect or replace temperature probe. 32

SYMPTOM Display shows blinking battery symbol. Meter does not work with temperature probe. Meter fails to calibrate or gives faulty readings. "WRONG CAL" is displayed during ph calibration procedure. Meter shuts off. "Er0, Er1, Er2" message at start up. "Clr" message at start up. PROBLEM Low battery level. Broken temperature probe. Broken ph electrode. Wrong or contaminated buffer. Dead batteries or auto-off feature is enable (in this case, meter shuts off after 20 minutes of non-use). EEPROM error. Loaded default ph calibration values. SOLUTION Change batteries. Replace the temperature probe. Replace electrode. Check that buffer solution is correct and fresh. Change batteries or press ON/OFF. Contact your dealer or any Adwa service center. Perform ph calibration. 33

WARRANTY Adwa warrants this product to be free of defects in material and workmanship as stated in the operating manual. If repair or adjustment is necessary and has not been the result of abuse, misuse or improper handling within the warranty period, please contact your dealer or the nearest Adwa Office for the RGA (Return Goods Authorization) number to put on the outside of your package. Warranted service will be made without charge. The meter is warranted for a period of 2 years, while probes are warranted for 6 months. The warranty period commences from the original date of sale. Warranty is only valid when the product is used under normal conditions and in accordance with the instruction manual. The warranty is void if the instrument is repaired or serviced by unauthorized personnel, not used in accordance to the instructions, or if non-adwa accessories such as buffer solutions, probes, etc. are used in conjunction with the meter. Adwa will not be held responsible for any accident whether directly or indirectly, caused by the use of this instrument. 34

35

ADWA HUNGARY Kft. Alsókikötõ sor 11, 6726 Szeged, Hungary Tel. +36 62 317 878 Fax +36 62 550 610 www.adwainstruments.com MANAD130 09/14