1 AR Operating manual ph 3110 ph C TP ph meter
2 ph 3110 Accuracy when going to press The use of advanced technology and the high quality standard of our instruments are the result of a continuous development. This may result in differences between this operating manual and your meter. Also, we cannot guarantee that there are absolutely no errors in this manual. Therefore, we are sure you will understand that we cannot accept any legal claims resulting from the data, figures or descriptions. Copyright Weilheim 2008, WTW GmbH Reproduction in whole - or even in part - is prohibited without the express written permission of WTW GmbH, Weilheim. Printed in Germany.
3 ph 3110 Contents ph Contents 1 Overview Keypad Display Socket field Safety Authorized use General safety instructions Commissioning Scope of delivery Initial commissioning Inserting the batteries Switching on the meter Operation General operating principles Operating modes Operation Measuring Measuring the ph value Measuring the ORP Calibration Calibration interval (Int.C) Automatic calibration (AutoCal) Conventional calibration (ConCal) Downloading calibration data Settings System settings Measurement settings Reset Resetting calibration values Resetting all meter settings Maintenance, cleaning, disposal Maintenance Replacing the batteries Cleaning Packing
4 Contents ph Disposal What to do if Technical data General data Measuring ranges, resolution, accuracy Lists
5 AR ph 3110 Overview 1 Overview The compact ph 3110 precision ph meter enables you to perform ph measurements rapidly and reliably. The ph 3110 provides the maximum degree of operating comfort, reliability and measuring certainty for all applications. The proven calibration procedures and automatic stability control function (AR) support your work with the ph meter ph C TP 1 1 Keypad 2 Display 3 Socket field 5
6 Overview ph Keypad ph 3110 In this operating manual, keys are indicated by brackets <..>. The key symbol (e.g. <ENTER>) generally indicates a short keystroke (under 2 sec) in this operating manual. A long keystroke (approx. 2 sec) is indicated by the underscore behind the key symbol (e.g. <ENTER_>). <On/Off>: <On/Off_>: <M>: <M_>: <CAL>: <CAL_>: < >: Switches the meter on/off Resets calibration data Selects the measured parameter Opens the setting menu for calibration and measurements Calls up the calibration procedure Displays the calibration data Increments values, scrolls < >: Decrements values, scrolls <ENTER>: <ENTER_> : Confirms entries Opens the setting menu for system settings 6
7 ph 3110 Overview 1.2 Display Status display Sensor symbol (calibration evaluation) Measured value display Function and temperature display indicators Function display indicators AutoCal TEC AutoCal DIN ConCal CalError LoBat AR TP TIME Calibration with automatic buffer recognition (buffer set: Technical buffers ) Calibration with automatic buffer recognition (buffer set: DIN buffers ) Calibration with any buffers An error occurred during calibration With battery operation: Batteries almost empty Stability control (AutoRead) is active Temperature measurement active Setting of calibration interval 7
8 Overview ph Socket field Connectors: 1 ph electrode 2 Reference electrode 3 Temperature sensor 4 Service interface Caution Only connect sensors to the meter that cannot return any voltages or currents that are not allowed (> SELV and > current circuit with current limiting). Almost all customary sensors fulfill these conditions. 8
9 ph 3110 Safety 2 Safety This operating manual contains basic instructions that you must follow during the commissioning, operation and maintenance of the meter. Consequently, all responsible personnel must read this operating manual before working with the meter. The operating manual must always be available within the vicinity of the meter. Target group The meter was developed for work in the field and in the laboratory. Thus, we assume that, as a result of their professional training and experience, the operators will know the necessary safety precautions to take when handling chemicals. Safety instructions Safety instructions in this operating manual are indicated by the warning symbol (triangle) in the left column. The signal word (e.g. "Caution") indicates the level of danger: Warning indicates instructions that must be followed precisely in order to avoid possibly great dangers to personnel. Caution indicates instructions that must be followed precisely in order to avoid the possibility of slight injuries or damage to the meter or the environment. Further notes indicates notes that draw your attention to special features. indicates cross-references to other documents, e.g. operating manuals. 9
10 Safety ph Authorized use This meter is authorized exclusively for ph and ORP measurements in a laboratory or field environment. The technical specifications as given in chapter 7 TECHNICAL DATA must be observed. Only the operation and running of the meter according to the instructions given in this operating manual is authorized. Any other use is considered unauthorized. 2.2 General safety instructions This meter is constructed and tested in compliance with the IEC 1010 safety regulations for electronic measuring instruments. It left the factory in a safe and secure technical condition. Function and operational safety The smooth functioning and operational safety of the meter can only be guaranteed if the generally applicable safety measures and the specific safety instructions in this operating manual are followed during operation. The smooth functioning and operational safety of the meter can only be guaranteed under the environmental conditions that are specified in chapter 7 TECHNICAL DATA. If the meter was transported from a cold environment to a warm environment, the formation of condensate can lead to the faulty functioning of the meter. In this event, wait until the temperature of the meter reaches room temperature before putting the meter back into operation. Caution The meter is only allowed to be opened by authorized personnel. 10
11 ph 3110 Safety Safe operation If safe operation is no longer possible, the meter must be taken out of service and secured against inadvertent operation! Safe operation is no longer possible if the meter: has been damaged in transport has been stored under adverse conditions for a lengthy period of time is visibly damaged no longer operates as described in this manual. If you are in any doubt, please contact the supplier of the meter. Obligations of the purchaser The purchaser of this meter must ensure that the following laws and guidelines are observed when using dangerous substances: EEC directives for protective labor legislation National protective labor legislation Safety regulations Safety datasheets of the chemical manufacturers. Caution In addition to the safety instructions mentioned here, also follow the safety instructions of the sensors used. The operating manuals of the sensors are available on the supplied CD and on the Internet under 11
12 Safety ph
13 ph 3110 Commissioning 3 Commissioning 3.1 Scope of delivery Handheld meter, ph batteries 1.5 V Mignon type AA Operating manual 3.2 Initial commissioning Perform the following activities: Insert the supplied batteries Switch on the meter Inserting the batteries 1 Unscrew the two screws (1) on the underside of the meter. 2 Open the battery compartment (2) on the underside of the meter Place four batteries (type Mignon AA) in the battery compartment. 13
14 Commissioning ph 3110 Alternatively, you can also use Ni-MH rechargeable batteries (type Mignon AA). In order to charge the batteries, an external charging device is required. Caution Make sure that the poles of the batteries are positioned correctly. The ± signs on the batteries must correspond to the ± signs in the battery compartment. 4 Close the battery compartment (2) and tighten the screws (1) Switching on the meter 1 Place the meter on a flat surface and protect it from intense light and heat. 2 Press the <On/Off> key. A display test is briefly displayed. Subsequently, the meter switches to the measuring mode (measured value display). The meter has an energy saving feature to avoid unnecessary battery depletion during battery operation. The energy saving feature switches off the meter if no key was pressed during the specified interval (setting the switch-off interval see section 4.5.1). 14
15 ph 3110 Operation 4 Operation 4.1 General operating principles This section contains basic information on the operation of the ph Operating modes The meter has the following operating modes: Measurement The display indicates the measurement data in the measured value display Calibration The display guides you through a calibration procedure with calibration information Configuration The system menu or a sensor menu with submenus, settings and functions is displayed Operation Keys Functions The meter is operated via keys. The keys can have different functions with long or short keystrokes. Generally, with a short keystroke a function is carried out. A long keystroke opens a setting menu. In a setting menu, settings are selected with the < >< > keys. A setting is confirmed with <ENTER>. With confirming, the setting is finished and the next setting is displayed. Representation In this operating manual, keys are indicated by brackets <..>. The key symbol (e.g. <ENTER>) generally indicates a short keystroke (under 2 sec) in this operating manual. A long keystroke (approx. 2 sec) is indicated by the underscore behind the key symbol (e.g. <ENTER_>). 15
16 Operation ph Measuring Preparatory activities Perform the following preparatory activities when you want to measure: 1 Connect the ph combination electrode to the meter. 2 Adjust the temperature of the buffer solutions or test solutions, or measure the current temperature, if you measure without a temperature sensor. 3 Calibrate or check the meter with the combination electrode. 4 Select the measured parameter with <M>. Incorrect calibration of ph combination electrodes leads to incorrect measured values. Calibrate regularly before measuring. Stability control AutoRead During the measuring procedure, the stability control function is automatically activated. The stability control function (drift control) checks the stability of the measured ph signal and the stability of the measured temperature signal. The stability has a considerable effect on the reproducibility of the measured value. For identical measurement conditions, the following applies: Measured parameter Reproducibility Response time ph value < 0.02 ph units > 15 seconds Temperature < 0.3 C of temperature value > 15 seconds Temperature sensor You can measure with or without a temperature sensor. If a temperature sensor is connected, it is indicated on the display by TP. The ph meter automatically recognizes the type of the temperature sensor used. Therefore, you can connect combination electrodes with an NTC30 or Pt1000. The temperature measurement is absolutely essential for a reproducible ph measurement. If the measurement is made without a temperature sensor, proceed as follows: 1 Measure the current temperature using a thermometer. 2 Set the temperature value with < >< >. 16
17 ph 3110 Operation When calibrating without temperature sensor, also set the current temperature of each buffer solution manually with the < >< > keys Measuring the ph value 1 Perform the preparatory activities according to section Immerse the ph combination electrode in the test sample. 3 Using <M>, scroll as necessary until the measured parameter ph is displayed. 4 Wait for a stable measured value. The AR display indicator flashes as long as the measured value is not yet stable. ph C TP AR 17
18 Operation ph Measuring the ORP The meter can, in conjunction with an ORP electrode, measure the ORP (mv) of a solution. 1 Perform the preparatory activities according to section Immerse the ORP electrode in the test sample. 3 If necessary, call up the measured parameter U with <M>. 4 Wait for a stable measured value. The AR display indicator flashes as long as the measured value is not yet stable. U mV C TP AR ORP electrodes are not calibrated. However, you can check ORP electrodes using a test solution. 18
19 ph 3110 Operation 4.3 Calibration Why calibrate? When do you have to calibrate? AutoCal ph combination electrodes age. This changes the zero point (asymmetry) and slope of the ph combination electrode. As a result, an inexact measured value is displayed. Calibration determines the current values of the zero point and slope of the combination electrode and stores them in the measuring instrument. Thus, you should calibrate at regular intervals. After connecting another combination electrode When the sensor symbol flashes on the display: e.g. after the calibration interval has expired is adapted to the permanently programmed buffer solutions as a fully automatic single-point, two-point or three-point calibration. The buffer solutions are automatically recognized by the meter. The following buffer sets are suitable: Technical buffers (AutoCal TEC) DIN buffers (AutoCal DIN) Calibration points Calibration can be performed using one, two or three buffer solutions in any order (single-point, two-point or three-point calibration). The meter determines the following values and calculates the calibration line as follows: Determined values Displayed calibration data 1-point ASY Zero point = ASY Slope = Nernst slope ( mv/ph at 25 C) 2-point 3-point ASY SLO Zero point = ASY Slope = SLO You can display the slope in the units, mv/ph or %. You can display the zero point in the units, mv or ph. ConCal Stability control AutoRead This function is a conventional two-point calibration using two buffer solutions (ph 7.0 ± 0.5 and any other buffer solution) or a single-point calibration using any buffer solution and is used as a high-speed method. The calibration procedure automatically activates the stability control function. The current measurement with stability control can be terminated at any time (accepting the current value) by pressing <ENTER>. 19
20 Operation ph 3110 Calibration record Displaying the calibration data Calibration evaluation When finishing a calibration, the new calibration values are first displayed as an informative message and stored. You can display the data of the last calibration (see section 4.4). After calibrating, the meter automatically evaluates the calibration. The zero point and slope are evaluated separately. The worse evaluation of both is taken into account. The evaluation appears on the display as the sensor symbol and in the calibration record. Sensor symbol Zero point [mv] Slope [mv/ph] or or Clean the combination electrode according to the electrode operating manual CalError Eliminate the error according to chapter 6 WHAT TO DO IF... < -30 or > or Preparatory activities 1 Switch on the meter with <On/Off>. 2 Connect the ph combination electrode to the meter. 3 Keep the buffer solutions ready. 4 Adjust the temperature of the solutions and measure the current temperature if the measurement is made without temperature sensor. 20
21 ph 3110 Operation 5 Set the buffer set to be used for calibration as necessary Calibration interval (Int.C) The calibration interval reminds you to calibrate regularly. When the adjusted calibration interval (Int.C) has expired, the sensor symbol flashes. It is still possible to measure. To ensure the high measuring accuracy of the measuring system, calibrate after the calibration interval has expired. Setting the calibration interval The calibration interval (Int.C) is set to 7 days (d7) in the factory. You can change the interval ( days): 1 Open the menu for measurement settings with <M_>. 2 Confirm all settings with <ENTER> until Int.C is displayed. ph Time 1 N T C D 8 3 Set the calibration interval with < >< >. 4 Confirm the setting with <ENTER>. 21
22 Operation ph Automatic calibration (AutoCal) For the AutoCal TEC and AutoCal DIN procedures, use one to three buffer solutions of the relevant buffer set (Technical buffers or DIN buffers) in any order. The steps 2 and 6 are not necessary if you use a temperature sensor. 1 Press <CAL> repeatedly until the AutoCal TEC or AutoCal DIN function display indicator appears. ph ph AutoCal TEC C T C C D I 2 4 TP 8 AutoCal DIN C TP 2 If necessary, set the temperature of the buffer solution with < >< >. 3 Immerse the ph combination electrode in the first buffer solution. 4 Start the measurement with <ENTER>. The AR display indicator flashes. The electrode voltage (mv) or the nominal value of the buffer (setting: see section 4.5.2) is displayed. As soon as a stable value is recognized, Ct2 or Cd2 appears. ph ph AutoCal TEC C T C C D TP 8 AutoCal DIN C TP 22
23 ph 3110 Operation Here you can cancel the calibration procedure with <M>. This corresponds to a single-point calibration. The value of the zero point (ASY) is displayed. Pressing <ENTER> displays the value of the slope (SLO). Continuing with twopoint calibration 5 Thoroughly rinse the combination electrode with distilled water. 6 If necessary, set the temperature of the second buffer solution with < >< >. 7 Immerse the combination electrode in the second buffer solution. 8 Press the <ENTER> key. The AR display indicator flashes. The electrode voltage (mv) or the nominal value of the buffer (setting: see section 4.5.2) is displayed. As soon as a stable value is recognized, Ct3 or Cd3 appears. ph ph AutoCal TEC C T C TP 8 AutoCal DIN C D C TP Here you can cancel the calibration procedure with <M>. This corresponds to a two-point calibration. The value of the zero point (ASY) is displayed. Pressing <ENTER> displays the value of the slope (SLO). Continuing with threepoint calibration 9 Thoroughly rinse the combination electrode with distilled water. 10 If necessary, set the temperature of the third buffer solution with < >< >. 11 Immerse the combination electrode in the third buffer solution. 23
24 Operation ph Press the <ENTER> key. The AR display indicator flashes. The electrode voltage (mv) or the nominal value of the buffer (setting: see section 4.5.2) is displayed. The asymmetry is displayed as soon as a stable value is recognized. 13 Press the <ENTER> key. The value of the slope (mv/ph) appears on the display. 14 To return to the measuring mode: Press the <ENTER> key. While the zero point (ASY) is being displayed, you can change the unit of the zero point with < >< >. While the slope (SLO) is being displayed, you can change the unit of the slope with < >< >. The % display refers to the Nernst slope of 59.2 mv/ph at 25 C (100 x determined slope/nernst slope). The unit of zero point and slope can also be changed permanently in the measurement settings (see section 4.5.2) Conventional calibration (ConCal) Single-point calibration Two-point calibration Use any buffer solution for this rapid method. The calibration will be the more exact the nearer the ph value of the buffer solution is to that of the test sample. Use two buffer solutions for this procedure: ph 7.0 ± 0.5 any other buffer solution The steps 2 and 9 are not necessary if you use a ph combination electrode with a temperature sensor. 1 Press the <CAL> key repeatedly until the ASY display indicator and the ConCal function indicator appear. 24
25 ph 3110 Operation A S Y C TP ConCal 2 If necessary, set the temperature of the first buffer solution with < >< >. 3 Immerse the ph combination electrode in the first buffer solution (ph 7.0 ± 0.5 for two-point calibration). 4 Press the <ENTER> key. The measured ph value appears on the display. 5 When the measured value is stable, using < >< >, set the measured value to the nominal ph value of the buffer solution (at the current temperature). 6 Press the <ENTER> key. SLO appears on the display. Here you can cancel the calibration procedure with <M>. This corresponds to a single-point calibration. The value of the zero point (ASY) is displayed. The sensor symbol shows the evaluation of the single-point calibration. Pressing <ENTER> displays the value of the slope (SLO). s L O C TP ConCal 25
26 Operation ph To continue the two-point calibration, thoroughly rinse the combination electrode with deionized water. 8 If necessary, set the temperature of the second buffer solution with < >< >. 9 Immerse the combination electrode in the second buffer solution. 10 Press the <ENTER> key. The second ph value appears on the display. 11 When the measured value is stable, using < >< >, set the measured value to the nominal ph value of the buffer solution (at the current temperature). 12 Press the <ENTER> key. The value of the zero point (ASY) is displayed. 13 Press the <ENTER> key. The value of the slope (SLO) is displayed. 14 Press the <ENTER> key. The measuring mode is active. While the zero point (ASY) is being displayed, you can change the unit of the zero point with < >< >. While the slope (SLO) is being displayed, you can change the unit of the slope with < >< >. The % display refers to the Nernst slope of 59.2 mv/ph at 25 C (100 x determined slope/nernst slope). The units of the zero point and slope can also be changed permanently in the measurement settings (see section 4.5.2). 26
27 ph 3110 Operation 4.4 Downloading calibration data You can download calibration data to the display as follows: 1 Pressing <CAL_> displays the calibration data (asymmetry). 0 2 mv A S y ConCal While the calibration data is displayed you can press < >< > to switch over the unit of the zero point (ASY). 2 With <ENTER> display the slope S L O 9 mv/ph ConCal While the calibration data is displayed you can press < >< > to switch over the unit of the slope (SLO). 27
28 Operation ph Settings You can adapt the meter to your individual requirements. The settings are done in the following menus: System settings (<ENTER_>) Switch-off interval (t.off) Measurement settings (<M_>) Display of the buffer during calibration (ph nominal value or measured voltage value in mv) Unit of the value for the slope (mv/ph or %) Unit of the value for the zero point (mv, ph) Measured value resolution, ph (0.000 / 0.00 / 0.0) Measured value resolution, U (0.0 / 0) Temperature unit ( C / F) Calibration interval (Int.C [ ]) You can exit the setting menu at any time by pressing <M>. Settings already modified and confirmed with <ENTER> are stored. 28
29 ph 3110 Operation System settings The default setting is printed in bold. Switch-off interval (t.off) 10, 20, 30, 40, 50 min, 1, 2, 3, 4, 5, 10, 15, 20, 24 h 1 Open the menu for system settings with <ENTER_>. The first system setting is displayed. Switch-off interval (t.off) Time t Of f Set the switch-off interval with < >< >. 3 Confirm with <ENTER>. The system settings are completed. The meter switches to the measuring mode. 29
30 Operation ph Measurement settings These settings apply to calibration and measurement (the default setting is printed in bold). Display during calibration (BUFFER) ph (buffer nominal value), U (combination electrode voltage) Unit of the value for the slope (SLO) mv/ph, % Unit of the value for the zero point (ASY) mv, ph Measured value resolution, ph 0.000, 0.00, 0.0 Measured value resolution, U 0.0, 0 Temperature unit (UnIt) C, F Calibration interval (Int.C) d 1 With <M_> open the menu for measurement and calibration settings. The first setting is displayed. Display during calibration (buff) ph b UF F ph AutoCal DIN AutoCal TEC 2 Using < >< >, select the ph or U display during calibration. 3 Confirm with <ENTER>. SLO, the unit of the value for the slope (mv/ph or %) is displayed. 30
31 ph 3110 Operation Unit of the value for the slope (SLO) ph S L O mv/ph 4 Using < >< >, select the unit for the slope. 5 Confirm with <ENTER>. ASY, the unit of the value for the zero point (mv or ph) is displayed. Unit of the value for the zero point (ASY) ph A S Y mv 6 Using < >< >, select the unit for the zero point. 7 Confirm with <ENTER>. res, the resolution of the ph display (0.0, 0.00 or 0.000) appears on the display. 31
32 Operation ph 3110 ph resolution (res) ph r e s o o oo 8 Select the resolution for the ph display with < >< >. 9 Confirm with <ENTER>. res, the resolution of the voltage display (0.0, 0.00 or 0.000) appears on the display. U resolution (res) U r e s oo mv 10 Using < >< >, select the unit for the voltage display. 11 Confirm with <ENTER>. Unit, the setting of the unit of the temperature value is displayed. 32
33 ph 3110 Operation Temperature unit (Unit) Un i o t C C TP 12 Using < >< >, toggle between C and F. 13 Confirm with <ENTER>. Int.C, the setting of the calibration interval is displayed. Calibration interval (Int.C) Time I N T C AutoCal DIN d 7 AutoCal TEC 14 Set the interval with < >< >. 15 Confirm with <ENTER>. The measurement settings are completed. The meter switches to the measuring mode. 33
34 Operation ph Reset Resetting calibration values This function resets the calibration values to the default condition. All other meter settings are retained. Calibration values in the default condition Zero point 0 mv (ph 7.000) Slope mv/ph (100 %) The measuring system is not calibrated after a reset. Before measuring, recalibrate the meter. Resetting calibration values 1 Press <On/Off_> to open the menu for the reset of the calibration data. Init.C is displayed. ph I ni t C n o 2 Press < >< > to display no or YES. YES: Reset the calibration values. no: Retain the calibration values. 3 Confirm with <ENTER>. The menu is finished. The meter switches to the measuring mode. 34
35 ph 3110 Operation Resetting all meter settings This function resets all meter settings to the default condition. The relevant values are given in the following sections: System settings section Measurement settings section Resetting the meter settings 1 Switch on the meter with <On/Off>. The display test appears briefly on the display. 2 During the display test, press <M> to open the menu for the reset of the meter settings. Init is displayed. I n i t n o 3 Press < >< > to display no or YES. YES: Reset the meter settings. no: Retain the meter settings. 4 Confirm with <ENTER>. The menu is finished. The meter switches to the measuring mode. The measuring system is not calibrated after a reset. Before measuring, recalibrate the meter. 35
36 Operation ph
37 ph 3110 Maintenance, cleaning, disposal 5 Maintenance, cleaning, disposal 5.1 Maintenance The only maintenance activity required is replacing the batteries. See the relevant operating manuals of the combination electrodes for instructions on maintenance Replacing the batteries 1 Unscrew the two screws (1) on the underside of the meter. 2 Open the battery compartment (2) on the underside of the meter Remove the four batteries from the battery compartment. 4 Place four new batteries (type Mignon AA) in the battery compartment. Alternatively, you can also use Ni-MH rechargeable batteries (type Mignon AA). In order to charge the batteries, an external charging device is required. Caution Make sure that the poles of the batteries are positioned correctly. The ± signs on the batteries must correspond to the ± signs in the battery compartment. 37
38 Maintenance, cleaning, disposal ph Close the battery compartment (2) and tighten the screws (1). 5.2 Cleaning Occasionally wipe the outside of the meter with a damp, lint-free cloth. Disinfect the housing with isopropanol as required. Caution The housing is made of synthetic material (ABS). Thus, avoid contact with acetone or similar detergents that contain solvents. Remove any splashes immediately. 5.3 Packing This meter is sent out in a protective transport packing. We recommend: Keep the packing material. The original packing protects the meter against damage during transport. 5.4 Disposal This meter contains batteries. Batteries that have been removed must only be disposed of at a recycling facility set up for this purpose or via the retail outlet. It is illegal to dispose of them in household refuse. 38
39 ph 3110 What to do if... 6 What to do if... Error message OFL, UFL Cause ph combination electrode: Measured value outside the measuring range Air bubble in front of the diaphragm Remedy Use suitable combination electrode Remove air bubble Air in the diaphragm Extract air or moisten diaphragm Cable broken Replace combination electrode Gel electrolyte dried out Replace combination electrode Error message CalError Cause ph combination electrode: The values determined for zero point and slope of the combination electrode are outside the allowed limits. Remedy Recalibrate Diaphragm contaminated Clean diaphragm Combination electrode broken Replace combination electrode Buffer solutions Incorrect buffer solutions Change calibration procedure Buffer solutions too old Use only once. the shelf life Buffer solutions depleted Change solutions 39
40 What to do if... ph 3110 No stable measured value Cause ph combination electrode: Remedy Diaphragm contaminated Clean diaphragm Membrane contaminated Clean membrane Test sample: ph value not stable Measure with air excluded if necessary Temperature not stable Adjust temperature if necessary Combination electrode + test sample: Conductivity too low Use suitable combination electrode Temperature too high Use suitable combination electrode Organic liquids Use suitable combination electrode Sensor symbol flashes Cause Remedy Calibration interval expired Recalibrate the measuring system Display, LoBat Cause Remedy Batteries almost empty Replace the batteries (see section 5.1 MAINTENANCE) 40
41 ph 3110 What to do if... Obviously incorrect measured values Cause ph combination electrode: ph combination electrode unsuitable Temperature difference between buffer and test sample too high Measurement procedure not suitable Remedy Use suitable combination electrode Adjust temperature of buffer or sample solutions Follow special procedure Meter does not react to keystroke Cause Operating condition undefined or EMC load unallowed Remedy Processor reset: Press the <ENTER> and <On/Off> key simultaneously You want to know which software version is in the meter Cause E. g., a question by the service department Remedy Switch on the meter. During the display test, display the software version with <ENTER>. 41
42 What to do if... ph
43 ph 3110 Technical data 7 Technical data 7.1 General data Dimensions approx. 240 x 190 x 80 mm Weight approx. 0.4 kg Mechanical structure Type of protection IP 67 Electrical safety Protective class III Test certificates CE Ambient conditions Storage - 25 C C Operation -10 C C Climatic class 2 Power supply Batteries Rechargeable batteries Operational life 4 x 1.5 V alkali-manganese batteries, type AA 4 x 1,2 V NiMH rechargeable batteries, type AA (no charging function) Approx h operating hours (batteries) Sensor input Input resistance > 5 * ohm Input current < 1 * A Guidelines and norms used EMC EC directive 2004/108/EC EN EN EN FCC Class A Meter safety EC directive 2006/95/EC EN Climatic class VDI/VDE 3540 IP protection EN
44 Technical data ph Measuring ranges, resolution, accuracy Measuring ranges, resolution Manual temperature input Variable Measuring range Resolution ph U [mv] T [ C] T [ F] Variable Range Increment T manual [ C] T manual [ F] Accuracy (± 1 digit) Variable Accuracy Temperature of the test sample ph / range * ± C C ± C C ± C C U [mv] / range ± C C ± C C T [ C] / temperature sensor NTC 30 ± 0.1 PT 1000 ± 0.1 * when measuring in a range of ± 2 ph around a calibration point The accuracy values specified here apply exclusively to the meter. The accuracy of the combination electrodes and buffer solutions has to be taken into account additionally. 44
45 ph 3110 Lists 8 Lists This chapter provides additional information and orientation aids. Specialist terms The glossary briefly explains the meaning of the specialist terms. However, terms that should already be familiar to the target group are not described here. Index The index helps you to find the topics that you are looking for. Glossary Adjusting Asymmetry AutoRange AutoRead Calibration Electromotive force of a combination electrode Junction Measured parameter To manipulate a measuring system so that the relevant value (e. g. the displayed value) differs as little as possible from the correct value or a value that is regarded as correct, or that the difference remains within the tolerance. see zero point Name of the automatic selection of the measuring range. Function to control the measured value stability. Comparing the value from a measuring system (e. g. the displayed value) to the correct value or a value that is regarded as correct. Often, this expression is also used when the measuring system is adjusted at the same time (see adjusting). The electromotive force U of the combination electrode is the measurable electromotive force of an electrode in a solution. It equals the sum of all the galvanic voltages of the electrode. Its dependency on the ph results in the electrode function, which is characterized by the parameters, slope and zero point. The junction is a porous body in the housing wall of reference electrodes or electrolyte bridges. It arranges the electrical contact between two solutions and makes the electrolyte exchange more difficult. The expression, junction, is also used for ground or junctionless transitions. The measured parameter is the physical dimension determined by measuring, e. g. ph, conductivity or D.O. concentration. 45
46 Lists ph 3110 Measured value Molality ORP voltage ph value Potentiometry Reset Resolution Slope Standard solution Test sample Zero point The measured value is the special value of a measured parameter to be determined. It is given as a combination of the numerical value and unit (e. g. 3 m; 0.5 s; 5.2 A; K). Molality is the quantity (in Mol) of a dissolved substance in 1000 g solvent. The ORP is caused by oxidizing or reducing substances dissolved in water, if these substances become effective at an electrode surface (e. g. a gold or platinum surface). The ph is a measure of the acidic or basic effect of an aqueous solution. It corresponds to the negative decadic logarithm of the molal hydrogen ions activity divided by the unit of the molality. The practical ph value is the value of a ph measurement. Name of a measuring technique. The signal (depending on the measured parameter) of the electrode is the electrical potential. The electrical current remains constant. Restoring the original condition of all settings of a measuring system. Smallest difference between two measured values that can be displayed by a measuring instrument. The slope of a linear calibration function. The standard solution is a solution where the measured value is known by definition. It is used to calibrate a measuring system. Designation of the test sample ready to be measured. Normally, a test sample is made by processing the original sample. The test sample and original sample are identical if the test sample was not processed. The zero point of a ph electrode is the ph value at which the electromotive force of the ph electrode at a specified temperature is zero. Normally, this is at 25 C. 46
47 ph 3110 Lists Index A Authorized use AutoCal AutoRead B Battery compartment , 37 Baud rate setting C Calibration Calibration evaluation ph Calibration interval Calibration points ph ConCal , 24 D Display E Energy saving feature I Initial commissioning Interval Calibration P Precautions R Reset All meter settings Calibration values Resolution setting , 31, 32 S Safety Scope of delivery Single-point calibration , 23, 25 Slope ph Socket field Stability control T Two-point calibration ConCal Z Zero point of ph combination electrode K Keys L LoBat M Measurement accuracy O Operation location Operational safety ORP electrode ORP voltage
48 Lists ph
49 Wissenschaftlich-Technische Werkstätten GmbH Dr.-Karl-Slevogt-Straße 1 D Weilheim Germany Tel: +49 (0) (0) Fax: +49 (0) [email protected] Internet:
Operating manual. ph 7110. ph meter
Operating manual ph 7110 ph meter ba75925e02 12/2011 ph 7110 Copyright Weilheim 2011, WTW GmbH Reproduction in whole - or even in part - is prohibited without the express written permission of WTW GmbH,
OPERATING MANUAL. ba77053d01 02/2014 6.093 25.0 C. 15.02.2014 08:37 USB output. Multi 3320 METER FOR 2 SENSORS (PH/ORP/D.O./COND)
15.02.2014 08:37 USB output ph OPERATING MANUAL ba77053d01 02/2014 6.093 25.0 C 3320 Multi 3320 METER FOR 2 SENSORS (PH/ORP/D.O./COND) Multi 3320 For the most recent version of the manual, please visit
Operating manual. ph 3310 6.093 HOLD AR 25.0 C. Menu 15.11.2008 08:37. ph meter. ba75802e02 12/2008
08:37 USB output Operating manual ph 3310 ph HOLD AR 6.093 25.0 C Menu 15.11.2008 ph meter ba75802e02 12/2008 ph 3310 Accuracy when going to press The use of advanced technology and the high quality standard
Operating manual. ph 7310 ph 7310P. Printermodul. ph 7310P. ph 7310. ph meter
Operating manual ph 7310 ph 7310P Printermodul ph 7310P ph 7310 ph meter ba75929e02 10/2011 ph 7310 Copyright Weilheim 2011, WTW GmbH Reproduction in whole - or even in part - is prohibited without the
Operating manual. ba75441e. inolab ph/cond 720. Measuring Instrument for ph, Redox, and Conductivity
Operating manual ba75441e inolab ph/cond 720 ph/cond 720 Measuring Instrument for ph, Redox, and Conductivity ba75441e01 03/2004 Accuracy when going to press The use of advanced technology and the high
Operating manual. ph/cond 3400i. Tref25 nlf C TP CAL. ph/conductivity measuring instrument. ba75687e01 01/2007
Operating manual ph/cond 3400i 5 3 0 Tref25 nlf 2 5 0 S/ C TP M AR STO CAL O AR ph/conductivity measuring instrument ba75687e01 01/2007 Accuracy when going to press The use of advanced technology and the
OPERATIONS MANUAL. ba76143e04 09/2015 4010-3. MultiLab 4010-3 DIGITAL METER FOR IDS SENSORS
4010-3 OPERATIONS MANUAL ba76143e04 09/2015 MultiLab 4010-3 DIGITAL METER FOR IDS SENSORS MultiLab 4010-3 For the most recent version of the manual, please visit www.ysi.com. Contact Copyright YSI 1725
Operating manual. Multi 340i. mg/l. ARng. ph/dissolved Oxygen/Conductivity Measuring Instrument. ba52318e02 03/2004
Operating manual Multi 340i O 7 9 2 M 1 7 6 ARng C TP mg/l STO CAL O AR ph/dissolved Oxygen/Conductivity Measuring Instrument ba52318e02 03/2004 Accuracy when going to press The use of advanced technology
SenTix 950 SenTix 980
SenTix 950 SenTix 980 ph combination electrodes with refillable liquid reference system Operating manual ba75843e01 08/2009 SenTix The latest version of the present operating manual can be found on the
ProLab 2000 ph/ise/d.o./conductivity
OPERATING MANUAL ba75577e05 04/2013 OK MENU ProLab 2000 ph/ise/d.o./conductivity MEASURING INSTRUMENT WITH AUTOMATIC SENSOR RECOGNITION AND ELECTRONIC ACCESS CONTROL CE conformity Radio data transmission
ph 200 ph-/redox-/temperature Meter Operating instructions
ph 200 ph-/redox-/temperature Meter Operating instructions 2 Table of Contents Page 1. Scope of delivery...4 2. System description...4 3. Connections...5 4. Display...7 5. Keypad...7 6. Start up...8 7.
Turb 550 / Turb 550 IR
Operating Manual ba41112e Turb 550 / Turb 550 IR Turbidity Measuring Instrument ba41112e03 04/2003 Accuracy when going to press The use of advanced technology and the high quality standard of our instruments
Hand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending
User Guide ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens Patent Pending Getting Started Remove the cap from the bottom of the ExStik TM to expose the electrode bulb and reference
MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL
MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL 430 350/REV A/10-03 MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL CONTENTS Introduction 1 Specification 2 Installation 3 Displays 3-4
Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3
Measuring ph in Water or CaCl2 Using a ph Meter Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3 PREPARING THE ph METER FOR USE (Calibration and Buffer Solutions) 4 When is Calibration
Ground Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
ExStik TM ph Waterproof Meters
User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL
Thermistor Thermometer MODEL NO. 93210-00
Thermistor Thermometer MODEL NO. 93210-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail:
Thermocouple Thermometer Models
Technology Made Easy... Thermocouple Thermometer Models 60010-00 (Type J) 60010-10 (Type K) 60010-20 (Type T) 68X309905 Rev 1 04/04 TABLE OF CONTENTS 1. INTRODUCTION 4 2. SAFETY PRECAUTIONS 6 3. SPECIFICATIONS
Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso
Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso SevenEasy Conductivity Italiano Español Français Deutsch English Contents Contents Page 1. Introduction...
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.
Instruction Sheet PN 51A-397/rev.F January 2011 Model 397 ph Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS MODEL 397 PERFORMANCE
Instruction Manual Temp 4/5/6 Temperature Meter Series
Instruction Manual Temp 4/5/6 Temperature Meter Series 68X243607 Technology Made Easy... Rev. 2 01/03-1 - Preface This instruction manual serves to explain the use of the Temp 4/5/6 temperature meter.
Pocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
Integrating Sound Level Meter and Datalogger
USER GUIDE Integrating Sound Level Meter and Datalogger Model 407780A Introduction Thank you for selecting the Extech Instruments Model 407780A. This device is shipped fully tested and calibrated and,
Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01
Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery
UltraBasic Benchtop ph Meter Operation Manual
UltraBasic Benchtop Meter Operation Manual UB-5 Denver Instrument Measuring 4 4 7 10 Meter 22.2 C 4.06 UltraBasic 902388.1 Rev. A UltraBasic Meter Quick Reference 1. Connect a AC adapter to the power connection.
photoflex / photoflex Turb
Quick start guide Kurzbedienungsanleitung Mode d'emploi abrégé Instrucciones breves de operación photoflex / photoflex Turb Portable photometer Page 3 Taschenphotometer Seite 27 Photomètre de poche Page
ph Logger WQL-pH PC Program WQL-Log
Operating manual ph Logger WQL-pH PC Program WQL-Log ph logger and PC program to display and evaluate measurement data from the logger ba75821e02 02/2010 DRAFT: Wednesday, 3. February 2010 Note The latest
IN-OUT Thermometer with Cable Free Sensor and Clock
IN-OUT Thermometer with Cable Free Sensor and Clock MODEL: RAR232 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RAR232 In-Out Thermometer with 433MHz cable free sensor and calendar
Operating Manual Electronic Wheelchair Scale with cable display M50610
Operating Manual Electronic Wheelchair Scale with cable display M50610 ADE GmbH & Co. Hammer Steindamm 27 29 D 22089 Hamburg Germany +49(40)432776-0 Fax +49(40)432776-10 E-mail: [email protected] Contents
Hygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN
User's Guide Digital Psychrometer Model RH390 MAX MIN F C WBT Dew Point Introduction Congratulations on your purchase of the Extech RH390 Digital Psychrometer. This device measures Humidity, Air Temperature,
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4
MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances
Operating Instructions MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances 15043 1/1.00 10 9 8 1 7 6 1 Display 2 Slider switch cd/m² segment test 3 ON/OFF switch 4
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
Operating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
XP Series Balances Operation Manual
XP Series Balances Operation Manual North and South America: 6542 Fig Street Arvada, Colorado 84 1-8-321-1135 Tel: 33-431-7255 Fax: 33-423-4831 U.K. and Ireland: Denver House, Sovereign Way Trafalgar Business
Operating instructions IV / 2007
General Operating instructions IV / 2007 Contents General Installation Application and function Application and function... 2 Safety information... 2 Design and dimensions... 3 Wiring diagram... 3 Installation
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
Portable digital microprocessor thermometers with interchangeable probes
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S
Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and
User s manual FLIR VP50/VP52 Non-contact AC voltage detector
User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions
User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600
User's Guide ExStik DO600 Dissolved Oxygen Meter II RECALL Dissolved Oxygen DO600 Introduction Congratulations on your purchase of the ExStik DO600 dissolved oxygen / temperature meter which simultaneously
Operating Manual Remote Cost Control Monitor
Operating Manual Remote Cost Control Monitor INTRODUCTION: Congratulations on purchasing the Remote Cost Control. This is a state-of-the-art power monitoring socket that is highly accurate and easy to
Resolution selectable from 0.01 and 0.001 ph. Range -2.000 16.000 ph. Accuracy ± 0.002 ph
ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or
Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!
BeoLab 6002 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION
Calibration Guide PREPARATION Adventurer Pro Adventurer Pro balances have two calibration methods: Span and Linearity. Some models have Internal Calibration (InCal ) for Span calibration. Ensure that the
RS DIGITAL THERMOMETER
RS DIGITAL THERMOMETER 1319A INSTRUCTION MANUAL C F MX MN AVG TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION... 1 2. SPECIFICATIONS... 1 3. NAME OF PARTS AND POSITIONS... 3 4. OPERATION INSTRUCTIONS... 5
Temperature Humidity Meter
971 Temperature Humidity Meter Users Manual PN 2441047 September 2005 Rev.1, 5/06 2005-2006 Fluke Corporation, All rights reserved. Printed in Taiwan All product names are trademarks of their respective
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
Paint Test Equipment. Stargloss Gloss Meter Data Sheet
Paint Test Equipment Stargloss Gloss Meter Data Sheet Coating Thickness Gloss Porosity Adhesion Surface Roughness Surface Cleanliness Climatic Conditions Electrostatic Inspectors Accessories Complies with
DAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
Rousseau 10. User Guide
Rousseau 10 User Guide Base station overview ➀ LED signals White, permanent light: - Base station ready, you can register a handset Slow flashing white light: - Paging call in progress - Active call (you
Refer to page 6 to page 19 for detailed instructions.
CODE:GZ0000297065 Refer to page 6 to page 19 for detailed instructions. Preface This manual describes the operation of the COMPACT CONDUCTIVITY METER, B-771. Be sure to read this manual before using the
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI
American Weigh Scales, Inc. CQ-Series Digital Pocket Scale 7 4 1 0. 8 9 5 6 2 3 x = - CALI + CALC MODE M CAL AC CE % TARE OFF ON MC MR CQ-350 (350x0.1g) CQ-500 (500x0.1g) User Manual CQ-Series Manual Thank
Milwaukee USER MANUAL
Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Portable Waterproof ph/dissolved Oxygen Meter
Notes Write down the name and information of your OKTON distributor here. OPERTING INSTRUTIONS OKTON 35632-Series Portable Waterproof /Dissolved Oxygen Meter WTERPROOF REDY MES % T /Dissolved Oxygen/ /
User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
BUSINESS. Elektronisches Türschloss. Installation and User Manual. www.burg-waechter.de. Ingeniously safe. Ingeniously simple.
Elektronisches Türschloss BUSINESS Set 5011 PINCODE Set 5012 FINGERSCAN Set 5013 E-KEY Ingeniously safe. Ingeniously simple. BA/MA TSE Set 5000 dp/fsc 04/2012 Installation and User Manual BURG-WÄCHTER
ph-meter 1140 and ph-meter 1140-X Instruction manual
ph-meter 1140 and ph-meter 1140-X Instruction manual Mettler-Toledo GmbH Process, Postfach, 8902 Urdorf, Switzerland Phone: +41 (1) 736 22 11 Telefax: +41 (1) 736 26 36 Warranty Defects occurring within
Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version
Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building
Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE
Sodium DOC316.53.01240 Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE Scope and application: For drinking water and process water. Test preparation Instrument-specific information This procedure
MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions
MAKING MODERN LIVING POSSIBLE living connect Installation and User Guide Danfoss Heating Solutions 2 living connect Thank you for buying a Danfoss product Danfoss Heating Solutions 3 Contents 1. System
Stove Guard Kit User Manual
Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration
Model UT713 OPERATING MANUAL
Model UT713 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC
UK s best selling phone brand. User Guide. BT Decor 2200 Corded Phone
UK s best selling phone brand User Guide BT Decor 2200 Corded Phone 2 This User Guide provides you with all the information you need to get the most from your phone. Before you make your first call you
Ground Resistance Clamp-On Tester
User s Manual Ground Resistance Clamp-On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants the basic instrument to be free of defects in parts and workmanship for one
WEATHER STATION Instruction Manual Cat. No. 35.1115.IT
WEATHER STATION Instruction Manual Cat. No. 35.1115.IT Thank you for choosing this wireless weather station from TFA. BEFORE YOU USE IT Please be sure to read the instruction manual carefully. This information
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements
Instruction Manual HI 96800 Refractometer for Refractive Index and Brix Measurements www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
User Guide. Temperature and Humidity Datalogger. Model 42280
User Guide Temperature and Humidity Datalogger Model 42280 Introduction Congratulations on your purchase of the Extech 42280 Thermometer and Relative Humidity Datalogger. The 42280 is a wall-mount, tripod
Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394
GE Industrial Sensing 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Druck DPI 104 Digital pressure indicator User manual - K394 A1.1 A1.2 B1 1 A2 B2 2 3 4 5 6 A1.3 8 7
ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:
BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data
When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.
BeoLab 11 Guide WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. Do not expose this equip ment to dripping or splashing and ensure that no objects
Wahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
804 Ti Stand. Manual 8.804.8001EN
804 Ti Stand Manual 8.804.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 [email protected] www.metrohm.com 804 Ti Stand Manual 8.804.8001EN 06.2010 ek Teachware
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Product Information Sheet UH28CS-12kV Hi Pot Tester
Product Information Sheet UH28CS-12kV ETL Prüftechnik GmbH Telefon: +49 711 83 99 39-0 E-Mail: [email protected] Carl-Peters-Straße 23 D-70825 Korntal-Münchingen Telefax: +49 711 83 99 39-9 Internet:
MULTI XS 3600. Battery charger. For lead-acid batteries 1,2-120Ah
MULTI XS 3600 Battery charger For lead-acid batteries 1,2-120Ah User s Manual and a guide to professional battery charging For Starter/Deep Cycle batteries EN INTRODUCTION Congratulations on your purchase
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101
INSTRUCTION MANUAL Contactless Clinical Infrared Thermometer GT-101 17 D GB F I E P NL AR A Dear customer, Thank you for your confi dence in Geratherm and congratulations on your purchase! By purchasing
KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184
EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49