Governor Gas Regulator

Similar documents
Commercial & Industrial Propane Regulators and Meters

1800C and 1800C-HC Series Service Regulators. Technical Bulletin

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

1805 Series Relief Valves

MODEL LP 225LP2 225LP4 Safety Relief Valves

Outdoor Cooking. Gas pressure Regulators & Accessories 2012 EDITION LPG & NATURAL GAS REGULATORS RE-02 DIVISION

EZR Series Pressure Reducing Regulator

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

289 Series Spring-Loaded Relief Valves

Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications

REGULATORS D& HD Series

NAVIEN AMERICA INC FITCH AVENUE

Pressure and Temperature Controls

WD600 STEAM TRAPS. Thermodynamic Steam Trap

SPERRYN GAS CONTROLS DELTA FLUID PRODUCTS LIMITED

The Unique Accelabar Flow Meter

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

OPTIMASS 1400 Technical Datasheet

Types 66R and 66RR Low-Pressure Relief Valves

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

VAD. Variable Area Desuperheaters

OEM-EP Pressure Controllers

Principles of Direct-Operated Regulators

Your safety and the safety of others are very important.

Type 99 Pressure Reducing Regulator

Commercial Gas Water Heaters

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

167D Series Switching Valves

G234X-55 Conventional Gas Boiler

GS-General Service Control Valves

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Incorrect use or failure of pressure regulators

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

1301 Series High-Pressure Regulators

Commercial Gas Water Heaters

T U R B I N E G A S M E T E R

PRESSURE REDUCING CONTROL VALVE

Cooling Capacity CFM in. w.c. (125 Pa)

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Laminar Flow Elements

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Pressure Switch for gas and air

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

PLUMBING RE-SUBMITTAL

Direct-Operated Pressure & Temperature Regulating Valves

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

4077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE FAX

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

AUTOMATIC CHANGEOVER MANIFOLD Series 915

Air Eliminators and Combination Air Eliminators Strainers

COUNTERBALANCE VALVES

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Recreational Vehicles

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Baumann Way Bronze or Stainless Steel Control Valve

400B SERIES DIAPHRAGM PUMP

automatic Changeover regulators and systems manifolds/changeover regulators

Compact pressure switch Flameproof enclosure Ex d Model PCA

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Air/Vacuum Valves. Removal of Air from Pipelines. Allow the Entry of Air into Pipelines. Application:

AIR LINE VALVES AND GAUGES

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Type EZR Relief Valve or Backpressure Regulator

Dryaire Desiccant System

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Micro Motion 3098 Gas Specific Gravity Meter

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

ECOCIAT. Domestic hot water heat recovery unit

For Multi-Parameter Meters see mvx

API Flanged Safety Relief Valves Series 526 CATALOG

LifeASSURE PFS Series Filter Cartridge Integrity Testing

Centro-Matic Automatic Lubrication Systems System Controls

Single Deadman 150 psi (10.3 bar) Air Lifting Bag (ALB) Controller

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

FILLING AND PURGING THE SYSTEM

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

PRESSURE REDUCING VALVES

F9MXE. Product Specifications

CCI 100 DPC DRAG Wellhead Production Choke Valve

BLADDER SURGE CONTROL SYSTEM

Sizing Pressure Regulators & Control Valves

Butterfly valves BVG, BVGF, BVA, BVAF, BVH, BVHS, BVHM

Nitrogen Blanketing for Methanol Storage and Transportation

PRESSURE REGULATORS GAS BACK PRESSURE

VAD Variable Area Desuperheaters

08.08 Vic-Check Valves

Copper Meter Resetters

Gas Risers and Transition Fittings

PREPIPED LIQUID FUEL MANIFOLDS PLPM

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

Transcription:

Governor Gas Regulator ANSI Z21.80a CSA 6.22a-2005 Inlet Pressures 25" W.C. to 5 PSIG Pressures To 2 PSIG

Governor Introduction Pietro Fiorentini s Governor line of gas regulators are designed to comply with the latest CSA and International standards for regulators suitable for indoor or outdoor installations with no modifications. The Governor family of regulators are ideal for all burner installations and for low pressure gas distribution sytems. The materials and soft parts used in the construction of the Governor regulators make them suitable for use with natural gas, LPG, Propane air and all other non corrosive gases. All the Governor regulators are equipped with balanced valve design for high outlet pressure accuracy regardless of any inlet pressure variation. The double diaphragm provides added security in case of primary diaphragm failure. The integral vent limiter eliminates the need for costly piping for indoor installations and complies with CSA guidelines. The number of regulator options sometimes eliminates the need for separate units and significantly reduces installation costs. Specifications - Inlet pressure: 4 w.c. to g - pressure range: 2 w.c to 4.3g (2 w.c. to 2.18 psi for the compact models 30051-52-52) - Minimum operating differential pressure P: 1 w.c. - CSA pressures to g for Compliance - Temperature class: -40 F to + 125 F - Suitable for use with Natural Gas, LPG, Propane-air and any non corrosive gas. - Available in a wide size range: NPT threaded ½", ¾", 1", 1" ¼, 1" 1/2, 2"; Flanged: 2 ½", 3", 4 01 Features - Integral Vent Limter - Straight-through (all sizes) or angle connections (1/2", ¾", 1") - Two active outlets (1/2", ¾", 1") - Can be mounted in any position - Upstream and downstream test ports - Optional Incorporated slam shut, both over and under pressure (1/2", ¾", 1") - Optional replaceable incorporated 50 Micron filter (all sizes) Installation Saving - The integral vent limiter and double diaphragm eliminate the need for vent piping for indoor installations. - High capacities, which allows the use of smaller sizes. - Straight-through or angle connections versions for ease installation.

Safe and Reliable - Integral vent limiter: non removable, for indoor and outdoor installations. - Double diaphragm for added safety and greater reliability of service. Adjustable spring Detail double diaphragm Detail integral vent limiter Detail balanced valve Typical sectional drawing with detail of the redundant main diaphragm g ap ral pr ve o n In te CS ved t lim A per iter High Performance - Balanced valve design provides increased capacity, high 500:1 turndown and stable regulation from low to high flow. - Complete lockup in absence of gas flow, bubble tight shut-off - Balanced Valve Design allows the regulator inlet pressure to change but the regulators outlet pressure holds setpoint. 02 CSA design certified for inlet pressure 2 and g. Inlet pressures above g require over pressure protection. Designed With Your Needs In Mind - Double Diaphragm - Balanced Valve - High Capacity - Straight-through or Angle Connections - Wide Size Range - Integral Pressure Test Points - Integral Filter (Optional) - Integral Slam Shut (Optional)

Governor CAPACITIES IN SCFH * For 30051/30052/30053 compact models, MAX OUTLET PRESSURE = 2.18 psi * For 30150 to 30158 standard models, MAX OUTLET PRESSURE = 4.3 30051 1/2" compact 30052 3/4" compact 30053 1" compact Press Set 1 Press Set 14" w.c. Press Set 14" w.c. 1/ 466 386 297 1/ 466 386 297 1/ 466 386 297 610 553 496 366 762 691 621 450 991 899 807 595 716 * 635 * 628 558 898 * 848 * 778 698 1,168 * 1,059 * 1,093 906 924 936 853 1,170 1,066 1,521 1,386 924 936 952 988 1,170 1,190 1,235 1,521 1,547 1,605 924 936 952 988 1,170 1,190 1,235 1,521 1,547 1,605 HIGH CAPACITY 03 and Number Press Set Point 30150 1/2" 14 w.c. Nu mber 30151 3/4" Pressur e Set 1 1/ 1,086 891 656 1/ 1,372 1,125 829 1,433 1,296 1,152 870 1,810 1,637 1,455 2,000 1,695 * 1,695 * 1,471 1,325 2,140 * 2,084 * 1,858 1,674 2,196 2,205 2,213 2,223 2,026 2,774 2,785 2,796 2,808 2,560 2,196 2,205 2,213 2,223 2,261 2,346 2,400 1,775 2,774 2,785 2,796 2,808 2,857 2,963 3,030 2,241 2,196 2,205 2,213 2,223 2,261 2,346 2,400 2,500 2,774 2,785 2,796 2,808 2,857 2,963 3,030 3,150 Spring Selection 2 w.c. - 5 w.c. 0.07-0.18 psi GREEN - 11.8 w.c. 0.14-0.42 9.8 w.c. - 27.5 w.c. 0.35-0.99 WHITE YELLOW 23.6 w.c. - 59 w.c. 0.8-2.1 55 w.c. - 118 w.c. 1.98 psi - 4.2 VIOLET ORANGE * CSA Certifed Line Pressure Flow Capacities @ 20" w.c. drop *

30152 1" Pressu re Set 1 Pressur e Set 30153 1-1/4" 1 Pressur e Set 30154 1-1/2" 1 Pressur e Set 30155 2" 14 w. c. Pressur e Set 30157/F 3" Flanged 14 w. c. Pressur e Set 30158/F 4" Flanged 14 w. c. 1/ 1,629 1,337 985 1/ 3,886 3,189 2,349 1/ 4,058 3,330 2,453 1/ 7,430 6,097 4,491 1/ 11,654 9,676 7,451 1/ 20,482 16,951 13,066 2,149 1,944 1,727 1,305 5,128 4,638 4,121 3,114 5,354 4,842 4,303 3,251 9,804 8,866 7,878 5,953 14,726 13,243 11,165 9,158 25,780 23,166 20,553 16,027 2,542 * 2,437 * 2,206 1,988 6,065 * 5,297 * 5,264 4,743 6,333 * 5,650 * 5,496 4,952 11,595 15,026 * 10,947 * 15,087 10,064 15,143 9,068 15,213 13,868 18,010 16,810 15,715 13,950 31,465 29,452 27,545 24,414 3,294 3,308 3,320 3,335 3,040 7,860 7,891 7,921 7,957 7,254 8,206 8,240 8,270 8,308 7,574 23,096 23,202 23,308 23,404 21,335 40,435 40,612 40,753 41,000 37,324 3,294 3,308 3,320 3,335 3,392 3,520 3,600 2,661 7,860 7,891 7,921 7,957 8,093 8,400 8,380 6,350 8,206 8,240 8,270 8,308 8,450 8,770 8,960 6,630 15,026 15,087 15,143 15,213 15,473 16,050 16,400 12,140 23,096 23,202 23,308 23,404 23,804 24,700 20,800 18,670 40,435 40,612 40,753 41,000 41,660 43,220 44,160 32,680 3,294 3,308 3,320 3,335 3,392 3,520 3,600 3,750 7,860 7,891 7,921 7,957 8,093 8,400 8,380 8,940 8,206 8,240 8,270 8,308 8,450 8,770 8.960 9,330 15,026 15,087 15,143 15,213 15,473 16,050 16,400 17,085 23,096 23,202 23,308 23,404 23,804 24,700 20,800 26,290 40,435 40,612 40,753 41,000 41,660 43,220 44,160 46,000 1 w.c. = 0.036 psi = 27.8 w.c. CONVERSIONS:LPG capacities: multiply the value in table x 0.6Nitrogen capa cities: multiply the value04 in table x 0.79Natural gas BTU/h capacities: multiply the value in table x 1000

Governor Same body for different configurations GOVERNOR WITH OR WITHOUT FILTER GOVERNOR WITH SLAM SHUT 05 GOVERNOR WITH VERTICAL OUTLET FLANGED GOVERNOR WITH INTEGRAL FLANGES Straight-trought connections (all sizes) Angle connections (1/2", ¾", 1") Dual outlet (1/2", ¾", 1")

Dimensions INLET PRESSURE OUTLET PRESSURE E F D C C D A B Size Number 1/2 NPT30051 30052 30053 30150 30151 30152 30153 30154 30155 30155/F 30156/F 30157/F 30158/F 3/4 NPT 1 NPT A 4.13 4.45 with filter 4 4.29 with filter 4 h 1/2 NPT 5.43 (*) 3/4 NPT 5.28 (*) 1 NPT 5.28 (*) 1-1/4 NPT 7.64 (*) 1-1/2 NPT 7.64 (*) 2 NPT 9.29 (*) 2 Flanged 2-1/2 Flanged 3 Flanged 4 Flanged 4.29 wit filter B 13.85 (*) 16.90 (*) 16.90 (*) 16.90 (*) 1/2 3/4 1 C 1/2 3/ 4 1 1 1/4 1 1/2 2 2 2 1/2 3 4 D E 5.59 5.59 5.59 6.89 6.89 6.89 10 10 12.44 F 13.74 16.81 17.09 19.76 Weight (lb) 1.54 1.54 1.54 2.75 2.75 2.75 7.49 7.49 12.34 22.71 27.56 27.56 27.56 06 (*) same dimensions with filter CSA design certified for inlet pressure 2 and g. Inlet pressures above g require over pressure protection. MATERIALS BODY ALLUMINUM ALLOY GD AISI 12/EN AB 46100 G AISI 9/EN AB 43100 COVERS ALLUMINUM ALLOY GD AISI 12/EN AB 46100 G AISI 9/EN AB 43100 ZAMA 3 INI EN 1774 EXTERNAL COATINGS POLYURETHANE PAINT ON REQUEST OPTIONAL EPOXY POLYMERIC DUST PAINT 170/180 C THICKNESS 30-40 MICRON