EZR Series Pressure Reducing Regulator
|
|
|
- George Cooper
- 9 years ago
- Views:
Transcription
1 EZR Series Pressure Reducing Regulator November 2015 Robust Quiet Operation Thoroughly Tested Exceptional Design W7399 TYPE EZR REGULATOR Internally Actuated W8136 TYPE EZROSX WITH INTEGRAL SLAM-SHUT DEVICE NPS 1, 1-1/4 x 1, 2 x 1, 2, 3, 4, 6 and 8 / DN 25, 32 x 25, 50 x 25, 50, 80, 100, 150, 200 and EW Body Sizes Figure 1. EZR Series Pressure Reducing Regulator D102626X012
2 8 W W7562 TYPE 161AY PILOT W8346 TYPE PRX PILOT TRIM PACKAGE 10 2 TYPE 161EB PILOT W7344 W TYPE 161EB PILOT MAINTENANCE TYPE EZR PRESSURE REDUCING REGULATOR Figure 2. EZR Series Features and Benefits Introduction The Type EZR pilot-operated, pressure reducing regulator is designed for natural gas transmission/distribution systems and industrial/commercial applications. The Type EZR provides smooth, quiet operation, tight shutoff and long life, even in dirty service. Its internally actuated metal plug eliminates disadvantages associated with boot-style regulators, and the specially engineered flow path deflects debris, protecting the seat from damage and erosion. The Type EZR is used in conjunction with a 161EB or 161AY Series pilot and Type 112 restrictor or with a PRX Series pilot (with integral restrictor). The Type EZR pressure reducing regulator can be converted to a high pressure relief valve or backpressure regulator by simply changing to a relief piloting system (refer to Bulletin 71.4:EZR). An optional inlet strainer prevents large particles from entering the main valve, limiting damage to internal parts. A Type 252 pilot supply filter (optional) can be added to keep pipeline debris from entering the pilot. For underpressure and/or overpressure protection, the Type EZR is available with an integral slam-shut device. 2
3 Features and Benefits Tight Shutoff The EZR Series uses a diaphragm and metal plug, eliminating the disadvantages of bootstyle regulators. When open, the metal plug deflects particles and debris away from the diaphragm. The result is enhanced resistance to particle erosion, which provides excellent shutoff over an extended life. When closed, loading pressure and the main spring push the diaphragm onto the tapered-edged seat on the cage. Debris Protection The specially engineered flow path, along with the metal plug, allows flow through the regulator without seat impingement. The addition of an optional inlet strainer prevents large particles from entering the regulator, eliminating damage to internal parts. An optional Type 252 pilot supply filter collects pipeline debris before it reaches the pilot, reducing the possibility of pilot clogging. Quiet Operation The specially engineered flow path allows flow through the center of the cage and down through the cage slots reduces operational noise, making the EZR Series an exceptionally quiet regulator. High Accuracy Multiple outlet pressure ranges and narrow proportional bands offered by the 161EB Series, 161AY Series and Type PRX/120 pilots provide the EZR Series with tight, accurate control. For applications requiring tighter control, using a Type 161AYM, 161EBM or PRX/120 pilot will increase the accuracy of the regulator. Long Life The robust design of the EZR Series with its metal plug and specially engineered flow path allows flow through the regulator without seat impingement. The diaphragm design eliminates the possibility of taking a set, a common problem with boot-style regulators. To prevent damage, the diaphragm is fully supported in both the open and closed positions. These features enable the EZR Series components to work longer with less wear and tear. Full Usable Capacity Fisher branded regulators are laboratory tested. 100 percent of the published flow capacity can be used with confidence. Thorough Laboratory Testing Emerson Process Management Regulator Technologies, Inc. state-ofthe-art flow laboratory allows thorough testing of all new designs. Tests are conducted on Fisher branded regulators for performance features such as flow, strength, shutoff, material compatibility and noise. Easy In-Line Maintenance Top-entry design reduces maintenance time. Trim parts can be inspected, cleaned and replaced without removing the body from the pipeline. No special alignment 9 10 W8136 W Figure 2. EZR Series Features and Benefits (continued) 14 is required when replacing the diaphragm. The EZR Series incorporates E-body construction, making it easy to change existing E-body regulators and control valves with an EZR Series trim kit. O-ring Design The EZR Series uses elastomer O-rings instead of gaskets, reducing maintenance and assembly time. In-Service Travel Indicator The optional travel indicator responds to the precise movement of the diaphragm and plug assembly and shows the actual valve position. The travel indicator makes in-service inspection and troubleshooting easy. Also, it can be used for remote alarming and monitoring stem position when combined with the Type 4310 or 4320 wireless position monitor
4 Versatility The EZR Series uses the E-body, making available the standard construction materials and end connections (ASME and EN) used by other E-body regulators and control valves. The 161AY Series pilots can handle inlet pressures up to 150 psig / 10.3 bar and outlet pressure from 6 in. w.c. to 7 psig / 15 mbar to 0.48 bar. The 161EB Series pilots can handle inlet pressures up to 1500 psig / 103 bar and outlet pressures from 5 to 700 psig / 0.35 to 48.3 bar. The Type PRX pilots can handle inlet pressures up to 1480 psig / 102 bar and outlet pressures up to 1000 psig / 69.0 bar. By changing to a relief piloting system (6358 Series pilots), a Type EZR pressure reducing regulator easily becomes a very effective high volume relief valve or backpressure regulator (refer to Bulletin 71.4:EZR). Easily Maintained Pilots The pilots are designed to allow quick and simple in-line trim inspection and parts replacement. Powder Paint Coating Fisher regulators are powder paint coated providing superior impact, abrasion and corrosion resistance. Slam-shut device Type EZROSX with slamshut device provides either overpressure (OPSO) or overpressure and underpressure (OPSO/UPSO) protection by completely shutting off the flow at the downstream system. Pilot Type Descriptions Type 161AY Low-pressure pilot with an outlet pressure range from 6 in. w.c. to 7 psig / 15 mbar to 0.48 bar. Pilot bleeds (exhausts) downstream through the sense (control) line. Type 161AYM The monitor version of the Type 161AY pilot. The pilot bleed (exhaust) is isolated from the sense (control) line. This pilot is used in monitoring systems requiring an isolated pilot bleed (exhaust). Type 161EB High accuracy pilot with an outlet pressure range from 5 to 350 psig / 0.34 to 24.1 bar. Pilot bleeds (exhausts) downstream through the sense (control) line. Type 161EBM The monitor version of the Type 161EB pilot. The pilot bleed (exhaust) is isolated from the sense (control) line. This pilot is used in monitoring systems requiring an isolated pilot bleed (exhaust). Type PRX/120 Outlet pressure range of 14.5 to 435 psig / 1 to 30.0 bar. The Type PRX/120 can be used as the pilot on single stage pressure reducing regulators, as the monitor pilot or as the working pilot in wide-open monitor systems, or as the working pilot for monitoring and working regulators in the working monitoring systems. The Type PRX has a double diaphragm which provides increased accuracy and sensitivity, an integral restrictor adjustment to allow adjustable opening and closing speeds and a damper adjustment to allow adjustments to make for inlet pressure variability and loading pressure oscillations. Type PRX/120-AP Outlet pressure range of 435 to 1000 psig / 30.0 to 69.0 bar. The Type PRX/120-AP can be used as the pilot on single stage pressure reducing regulators, as the monitor pilot or as the working pilot in wide-open monitor systems, or as the working pilot for monitoring and working regulators in the working monitoring systems. Type PRX/125 (Monitor Pilot Only) Identical to the Type PRX/120 except the restriction screw is removed. The Type PRX/125 can only be used as the monitor override pilot on working monitor applications. Always order with Type PRX-120 in working monitor applications. Type PRX/125-AP (Monitor Pilot Only) Identical to the Type PRX/120-AP except the restriction screw is removed. The Type PRX/125-AP can only be used as the monitor override pilot on working monitor applications. Always order with Type PRX/120-AP in working monitor applications. Pilot Selection Considerations When selecting pilots to use with the EZR Series: Use the 161 Series pilots for applications where normal flow is typically 5% and greater of maximum rated flow. The accuracy and control of the 161 Series pilots can be increased using the series monitor pilots (M). When the potential for low flow (< 5% of maximum rated flow) for extended periods exists due to the regulator being oversized or operational constraints the Type PRX pilot is recommended. Additional details on how to set up the pilots for various flow rates is provided in the Type EZR Instruction Manual. If you have questions on which pilot to use for your application contact your local Sales Office. Optional Pilot Supply Filter The Type 252 pilot supply filter prevents pipeline debris from entering the pilot, a primary cause of pilot clogging. The aluminum body is rated for 2150 psig / 148 bar and the stainless steel body for 2750 psig / 190 bar. Both are available in standard or extended length with a pipe plug or a drain valve. When the upstream system is free of debris, the EZR Series may be installed without a filter. 4
5 Specifications This section lists the specifications for the EZR Series pressure reducing regulator. The set pressure range for a pilot as it comes from the factory appears on the spring case. Other information for an individual main valve appears on the nameplate. Available Configurations Type EZR: Pilot-operated pressure reducing regulator for low to high outlet pressure Type EZROSX: Type EZR with a Type OS2 slamshut device for overpressure (OPSO) or overpressure and underpressure (OPSO/UPSO) protection Main Valve Body Sizes, End Connection Styles and Structural Design Ratings (1)(2) See Table 1 Maximum Inlet Pressures and Pressure Drops (1) Main Valve: See Table 7 Pilots: See Table 3 Restrictor: 1500 psig / 103 bar Outlet (Control) Pressure Ranges See Table 2 Main Valve Plug Travel NPS 1, 1-1/4 x 1, 2 x 1 / DN 25, 32 x 25, 50 x 25: 0.37 in. / 9.4 mm NPS 2 / DN 50: 0.68 in. / 17 mm NPS 3 / DN 80: 0.98 in. / 25 mm NPS 4 / DN 100: 1.19 in. / 30 mm NPS 6 / DN 150: 1.5 in. / 38 mm NPS 8 / DN 200: 1.75 in. / 44 mm Minimum and Maximum Differential Pressures (1) See Tables 4 and 8 Main Valve Flow Direction Up through the center of the cage and down through the cage slots Proportional Bands See Table 2 Regulating Capacities See Tables 13, 14 and 15 Flow Coefficients Main Valve: See Tables 9 and 10 Pilots: See Table 11 Restrictor: See Table 12 IEC Sizing Coefficient See Table 8 Pressure Registration External Temperature Capabilities (1) See Table 6 Approximate Weights See Table The pressure/temperature limits in this Bulletin and any applicable standard or code limitation should not be exceeded. 2. Ratings and end connections other than ASME standards can usually be provided; contact your local Sales Office. - continued - Options Pre-piped Pilot Supply and Pilot Bleed Travel Indicator Inlet Strainer Type 252 Pilot Supply Filter Trim Package Restricted Capacity Trim Pilot Diaphragm for Pressure Loading Construction Materials EZR Series Main Valve Body: Cast iron, WCC steel or LCC steel Bonnet: Steel Bonnet Bushing: Stainless steel Cage: Stainless steel Spring: Zinc-plated steel or Stainless steel Top Plug: Stainless steel Bottom Plug: Stainless steel Inlet Strainer: Stainless steel Strainer Replacement Shim: Stainless steel Diaphragm: Nitrile (NBR) or Fluorocarbon (FKM) O-rings: Nitrile (NBR) or Fluorocarbon (FKM) Flanged Locknut: Zinc-plated steel Backup Rings: Polytetrafluoroethylene (PTFE) Upper Spring Seat: Stainless steel Indicator Protector and Cover: Plastic Indicator Stem: Stainless steel Indicator Fitting: Stainless steel Travel Indicator Plug: Stainless steel Restricted Trim E-Ring: Carbon steel Restrictor Plate: Stainless steel 161EB Series Pilots Body: Stainless steel Spring Case: Stainless steel Body Plug: Stainless steel Control Spring: Zinc-plated steel Valve Plug: Nitrile (NBR) or Fluorocarbon (FKM) Adjusting Screw: Zinc-plated steel Diaphragm: Nitrile (NBR) or Fluorocarbon (FKM) Diaphragm Limiter: Stainless steel O-rings: Nitrile (NBR) 161AY Series Pilots Body: Cast iron Spring Case and Lower Casing: Ductile iron Stem Guide: Stainless steel Control Spring: Zinc-plated steel Lever Assembly: Stainless steel Pusher Post: Stainless steel 5
6 Specifications (continued) 161AY Series Pilots (continued) Diaphragm: Nitrile (NBR) or Fluorocarbon (FKM) O-rings: Nitrile (NBR) or Fluorocarbon (FKM) Orifice: Stainless steel Disk Assembly: Nitrile (NBR) or Fluorocarbon (FKM) PRX Series Pilots Body: Steel Trim: Stainless steel Elastomers: Nitrile (NBR) or Fluorocarbon (FKM) Disk Material: Polyurethane (PU) or Fluorocarbon (FKM) Mounting Parts Pilot Mounting Pipe Nipple: Plated steel Tubing and Fittings: Stainless steel Type 112 Restrictor Body: Stainless steel Groove Valve: Stainless steel Retainer: Stainless steel Pipe Plug: Stainless steel O-rings: Fluorocarbon (FKM) Type 252 Pilot Supply Filter Body: Aluminum or Stainless steel Filter Cartridge: Polyethylene O-rings: Nitrile (NBR) Drain Valve or Pipe Plug: Stainless steel Slam-Shut Device Mechanism Box: Aluminum alloy First and Second Stage Mechanism: Steel Diaphragm: Nitrile (NBR) Bellows: Stainless steel Table 1. Main Valve Body Sizes, End Connection Styles and Body Ratings 6 TYPE EZR EZROSX MAIN VALVE BODY SIZE MAIN VALVE END CONNECTION STYLE BODY MATERIAL (1) STRUCTURAL DESIGN RATING (2) NPS DN psig bar 2 x 1, 2, 3, 4 and 6 1, 1-1/4 x 1 (3), 2 x 1, 2, 3, 4, 6 x 4 (4), 8 x 4 (4), 6, 8 x 6 (4) and 12 x 6 (4) 50 x 25, 50, 80, 100 and , 32 x 25 (3), 50 x 25, 50, 80, 100, 150 x 100 (4), 200 x 100 (4), 150, 200 x 150 (4) and x 150 (4) Cast iron WCC Steel LCC Steel 1, 2 x 1, 2, 3, 4 and 6 25, 50 x 25, 50, 80, 100 and 150 WCC Steel NPT 2 x 1 and 2 only CL125 FF CL RF NPT or SWE NPS 1, 2 x 1 and 2 only / DN 25, 50 x 25 and 50 only CL150 RF CL RF CL600 RF or BWE CL150 RF CL RF CL600 RF CL150 RF CL RF CL600 RF Ratings and end connections for other than ASME standard can usually be provided. Contact your local Sales Office for assistance. 2. See Tables 3, 6, 7 and 8 for diaphragm materials and additional pressure ratings. 3. Available in steel NPT only. 4. NPS 6 x 4, 8 x 4, 8 x 6, 12 x 6 / DN 150 x 100, 200 x 100, 200 x 150, x 150 Types EZR and 399 bodies are not the same as the EW valve bodies and are not interchangeable. Table 2. Outlet (Control) Pressure Ranges and Typical Proportional Bands TYPE 161AY or 161AYM 161EB or 161EBM OUTLET (CONTROL) PRESSURE RANGE PROPORTIONAL BAND (1)(3) PILOT CONTROL SPRING INFORMATION Wire Diameter Free Length psig bar Part Number Color Code psig bar In. cm In. cm 6 to 15 in. w.c. 0.5 to to to to 7 5 to to to to to to to 37 mbar 0.03 to to to to to to to to 10 9 to to 24 1 in. w.c. 1 in. w.c mbar (2) 3 mbar (2) 0.03 (2) 0.03 (2) 0.03 (2) 0.03 (2) 0.03 (2) 0.04 (2) 0.09 (2) 0.10 (2) 0.21 (2) 1B B B B B B1260X012 17B1262X012 17B1259X012 17B1261X012 17B1263X012 17B1264X012 Olive drab Yellow Light green Light blue Black White Yellow Black Green Blue Red 161EB (4) 30 to 2.1 to A9258X012 Green OUTLET (CONTROL) PRESSURE RANGE PILOT CONTROL SPRING INFORMATION TYPE ACCURACY CLASS (AC) psig bar (1) Wire Diameter Free Length Part Number Color Code In. cm In. cm PRX/120 PRX/ to to to to to to to to to to to to to to % 2.5% 2.5% 2.5% 1% 1% 1% M X12 M X12 M X12 M X12 M X12 M X12 M X12 Yellow Green Blue Black Silver Gold Aluminum PRX/120-AP 435 to to 69 1% M X12 Clear PRX/125-AP 1. Proportional band and Accuracy Class include outlet pressure drop plus hysteresis (friction), but do not include lockup. 2. Proportional band was determined with a pressure drop ranging from 50 to 150 psig / 3.5 to 10 bar. Approximately double the proportional band if the pressure drop is less than 50 psig / 3.5 bar. 3. With Type 112 restrictor set on 2. With Type PRX restrictor turn the restrictor screw one turn counterclockwise from fully seated. 4. Should only be used as the intermediate reduction pilot on the Type EZR worker/monitor systems
7 Table 3. Pilot Pressure Ratings TYPE MAXIMUM INLET PRESSURE MAXIMUM EMERGENCY OUTLET PRESSURE OR MAXIMUM EMERGENCY SENSE PRESSURE (1) MAXIMUM BLEED (EXHAUST) PRESSURE FOR MONITOR PILOT psig bar psig bar psig bar 161AY EB AYM EBM PRX Series Maximum pressure to prevent the casings from bursting during abnormal operation (leaking to atmosphere and internal parts damage might occur). Table 4. Main Valve Minimum Differential Pressures (1) MAIN VALVE BODY SIZE NPS DN 1, 1-1/4 x 1 25, 32 x 25 2 x 1 50 x MAIN SPRING PART NUMBER AND COLOR DIAPHRAGM MATERIAL MINIMUM DIFFERENTIAL, PERCENT OF CAGE CAPACITY For 90% Capacity For Capacity Trim Trim Trim Trim Trim Trim psid bar d psid bar d psid bar d psid bar d psid bar d psid bar d 19B2400X012, Light Blue 17E68 and 17E GE12727X012, Black 17E E68 and 17E B2401X012, Black with White Stripe (3) 17E88 and 17E B2400X012, Light Blue 17E68 and 17E B2401X012, Black with White Stripe 17E E68 and 17E GE11X012, Red Stripe (3) 17E B0951X012, Yellow (2) 17E68 and 17E B2126X012, Green 17E E68 and 17E , 6 x 4 and 8 x 4 6, 8 x 6 and 12 x 6 100, 150 x 100 and 200 x , 200 x 150 and x B5955X012, Red (3) GE05504X012, Purple (3) 17E88 and 17E T14184T0012, Yellow (2) 17E68 and 17E B0781X012, Light Blue 17E E68 and 17E B0782X012, Black (3) 17E88 and 17E T14184T0012, Yellow (2) 17E68 and 17E B8501X012, Green 17E E68 and 17E B8502X012, Red (3) 17E88 and 17E B0364X012, Yellow (2) 17E E B0366X012, Green 17E E B0365X012, Red (3) 17E88 and 17E GE09393X012, Yellow (2) GE09396X012, Green 17E GE09397X012, Red (3) See Table 1 for structural design ratings, Table 3 for pilot ratings and Table 7 for maximum pressure ratings. 2. The white and yellow springs are only recommended for inlet pressures under 100 psig / 6.9 bar. 3. The red, black, purple, red stripe and black with white stripe springs are only recommended for applications where the maximum inlet pressure can exceed 500 psig / 35 bar. 7
8 161AY SERIES PILOT 161EB SERIES PILOT FLOW DIRECTION TYPE 112 RESTRICTOR B2625_2 TYPE 252 PILOT SUPPLY FILTER MAIN SPRING DIAPHRAGM AND PLUG ASSEMBLY 3A TYPE EZR WITH TYPES 161EB PILOT, 112 RESTRICTOR AND 252 FILTER W7438 INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE LOADING PRESSURE Figure 3. Type EZR Operational Schematic 8
9 PRX SERIES PILOT TYPE 252 PILOT SUPPLY FILTER RESTRICTOR DAMPER S B L A MAIN SPRING DIAPHRAGM AND PLUG ASSEMBLY FLOW DIRECTION E0790 S - SUPPLY PORT B - BLEED PORT L - LOADING PORT A - SENSING PORT 3B TYPE EZR WITH PRX SERIES PILOT AND TYPE 252 FILTER SCHEMATIC INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE LOADING PRESSURE Figure 3. Type EZR Operational Schematic (continued) Principle of Operation As long as the outlet (control) pressure is above the outlet pressure setting, the pilot valve plug or disk remains closed (Figure 3). Force from the main spring, in addition to inlet pressure bleeding through the restrictor (integral in the PRX Series pilots), provide downward loading pressure to keep the main valve diaphragm and plug assembly tightly shutoff. When the outlet pressure decreases below the pilot outlet pressure setting, the pilot plug or disk assembly opens. Loading pressure bleeds downstream through the pilot faster than it can be replaced through the supply line. This reduces loading pressure on top of the main valve diaphragm and plug assembly and lets the unbalanced force between inlet and loading pressure overcome the main spring force to open the Type EZR diaphragm and plug assembly. As the outlet pressure rises toward the outlet pressure setting, it compresses the pilot diaphragm against the pilot control spring and lets the pilot valve plug or disk close. Loading pressure begins building on the Type EZR diaphragm and plug assembly. The loading pressure, along with force from the main spring, pushes the diaphragm and plug assembly onto the taperededge seat, producing tight shutoff. Installation (Figure 8) The robust design of the Type EZR regulator allows it to be installed indoors or outdoors. When installed outdoors, the Type EZR does not require a protective housing. It is designed to withstand the elements and the powder paint coating protects it against impacts, abrasions and corrosion. When installed indoors, no remote venting is required except on the pilot spring case. This regulator can also be installed in a pit that is subject to flooding by venting the pilot spring case above the maximum possible flood level so the pilot setting can be referenced at atmospheric pressure. 9
10 1 1 Bulletin 71.2:EZR ELASTOMER/FABRIC MATERIAL CODE THICKNESS CODE YEAR OF MANUFACTURE RADIAL LOCATION TO LOCATE IMPRINT CODE Table 5. Diaphragm Imprint Codes 1 11 THICKNESS MATERIAL Imprint Ink Code Imprint Ink Code DIAPHRAGM MATERIAL E68 17E68 - Nitrile (NBR) (low temperature) E88 17E88 - Fluorocarbon (FKM) (high aromatic hydrocarbon content resistance) LOCATE INK CODE BETWEEN RADII DOME IDENTIFICATION 5 17E97 17E97 - Nitrile (NBR) (high-pressure and/or erosion resistance) MATERIAL INK CODE Figure 4. Diaphragm Markings Monitoring Systems THICKNESS INK CODE (USE ONE LOCATION ONLY) MANUFACTURER CODE Monitoring regulation is overpressure protection by containment, therefore, there is no relief valve to vent to the atmosphere. When the working regulator fails to control the pressure, a monitor regulator installed in series, which has been sensing the downstream and control pressure, goes into operation to maintain the downstream pressure at a slightly higher than normal pressure. During an overpressure situation, monitoring keeps the customer on line. Also, testing is relatively easy and safe. To perform a periodic test on a monitoring regulator, increase the outlet set pressure of the working regulator and watch the outlet pressure to determine if the monitoring regulator takes over at the appropriate outlet pressure. Wide-Open Monitoring Systems (Figure 5) There are two types of wide-open monitoring systems: upstream and downstream. The difference between upstream and downstream monitoring is that the functions of the regulators are reversed. Systems can be changed from upstream to downstream monitoring and vice-versa, by simply reversing the setpoints of the two regulators. The decision to use either an upstream or downstream monitoring system is largely a matter of personal preference or company policy. In normal operation of a wide-open configuration, the working regulator controls the system s outlet pressure. With a higher outlet pressure setting, the monitor regulator senses a pressure lower than its setpoint and tries to increase outlet pressure by going wide-open. If the working regulator fails, the monitoring regulator assumes control and holds the outlet pressure at its outlet pressure setting. In a wide-open EZR monitoring system, system lockup will equal the lockup of the worker regulator on both an upstream monitor when the upstream pilot exhaust is piped to the intermediate pressure and a downstream monitor with upstream pilot exhaust piped to either intermediate pressure or outlet pressure. With these configurations, the diaphragm of the monitor regulator will change position with every load change. On an upstream monitor with the upstream pilot exhaust piped to downstream, lockup will occur at the monitor s setpoint and the diaphragm of the monitor regulator will be fully open. Working Monitoring Regulators (Figure 6) In a working monitoring system, the upstream regulator requires two pilots and it is always the monitoring regulator. The additional pilot permits the monitoring regulator to act as a series regulator to control an intermediate pressure during normal operation. In this way, both units are always operating and can be easily checked for proper operation. In a working monitor system, system lockup will equal the lockup of the downstream regulator. In normal operation, the working regulator controls the outlet pressure of the system. The monitoring regulator s working pilot controls the intermediate pressure and the monitoring pilot senses the system s outlet pressure. If the working regulator fails, the monitoring pilot will sense the increase in outlet pressure and take control. 10
11 Bulletin 71.2:EZR RESTRICTOR TYPE 252 PILOT SUPPLY FILTER RESTRICTOR TYPE 252 PILOT SUPPLY FILTER 161 SERIES PILOT 161 SERIES PILOT E0757 TYPE EZR-161 WIDE-OPEN MONITOR SENSE R UN R UN S TAR T S TAR T IN OUT M1128 TYPE EZR-161 WIDE-OPEN MONITOR WITH PILOT EXHAUST TO INTERMEDIATE PRESSURE INLET PRESSURE OUTLET PRESSURE ATMOSHERIC PRESSURE LOADING PRESSURE INTERMEDIATE PRESSURE Figure 5. Type EZR Wide-Open Monitor Schematic 11
12 TYPE PRX/120 PILOT TYPE PRX/120 PILOT S B S B FILTER L A FILTER L A INLET INTERMEDIATE OUTLET M1252 TYPE EZR-PRX WIDE-OPEN MONITOR S - SUPPLY PORT B - BLEED PORT L - LOADING PORT A - SENSING PORT TYPE PRX 120 PILOT TYPE PRX 120 PILOT S B FILTER L A FILTER INLET INTERMEDIATE OUTLET M1000 TYPE EZR-PRX WIDE-OPEN MONITOR WITH PILOT EXHAUST TO INTERMEDIATE PRESSURE WITH PILOT EXHAUST TO INTERMEDIATE PRESSURE INLET PRESSURE OUTLET PRESSURE ATMOSHERIC PRESSURE LOADING PRESSURE INTERMEDIATE PRESSURE S - SUPPLY PORT B - BLEED PORT L - LOADING PORT A - SENSING PORT Figure 5. Type EZR Wide-Open Monitor Schematic `(continued) 12
13 TYPE PRX/120 WORKING PILOT TYPE PRX/125 MONITOR PILOT (NO RESTRICTOR SCREW) TYPE PRX/120 PILOT S B S L B S B FILTER L A A (PLUGGED) FILTER L A INLET INTERMEDIATE OUTLET M1001 INLET PRESSURE OUTLET PRESSURE ATMOSHERIC PRESSURE LOADING PRESSURE INTERMEDIATE PRESSURE S - SUPPLY PORT B - BLEED PORT L - LOADING PORT A - SENSING PORT Figure 6. Type EZR-PRX-PRX Working Monitor Schematic For PRX Series pilots (Figure 6), the working pilot is Type PRX-120 or PRX-120AP; the monitor pilot is Type PRX-125 or PRX-125AP. Note The downstream regulator must be rated for the maximum allowable operating pressure of the system because this will be its inlet pressure if the monitoring regulator fails. Also, the outlet pressure rating of the monitoring pilot and any other components that are exposed to the intermediate pressure must be rated for full inlet pressure. Working monitor installations require a Type EZR main valve with a 161AY Series, 161EB Series, Type PRX/120 or PRX/120-AP working pilot and a Type 161AYM, 161EBM, PRX/125 or PRX/125-AP monitoring pilot for the upstream regulator and a Type EZR with the appropriate 161AY Series, 161EB Series, Type PRX/120 or PRX/120-AP pilot for the downstream regulator. Overpressure Protection Overpressuring any portion of a regulator or associated equipment may cause personal injury, leakage or property damage due to bursting of pressure-containing parts or explosion of accumulated gas. Provide appropriate pressure relieving or pressure limiting devices to ensure that the limits in the Specifications section are not exceeded. Regulator operation within ratings does not prevent the possibility of damage from external sources or from debris in the pipeline. Common methods of external overpressure protection include relief valves, monitoring regulators and shutoff devices. Type EZROSX regulator relies on the integrated slamshut device for overpressure (OPSO) or overpressure and underpressure (OPSO/UPSO) protection. In the event that outlet pressure rises above or falls below the pressure setting, slam shut will completely shutoff the flow of gas to the downstream system. 13
14 Table 6. Diaphragm Temperature Capabilities, Erosion Resistance and Chemical Compatibility Gas Temperature (for lower temperatures contact your local Sales Office) General Applications 17E68 NITRILE (NBR) 17E97 (1) NITRILE (NBR) 17E88 FLUOROCARBON (FKM) -20 to 150 F / -29 to 66 C 0 to 150 F / -18 to 66 C 0 to 260 F / -18 to 127 C (2) Best for cold temperatures. Best for high pressure conditions, i.e. transmission service or high pressure industrial service. It is also the best for abrasive or erosive service applications. Best for natural gas having aromatic hydrocarbons. It is also the best for high temperature applications. Heavy Particle Erosion Fair Excellent Good Natural Gas With: Up to 3% aromatic hydrocarbon content (3) Good Excellent Excellent 3 to 15% aromatic hydrocarbon content (3) Poor Good Excellent 15 to 50% aromatic hydrocarbon content (3) Not recommended Poor Excellent Up to 3% H 2S (hydrogen sulfide or sour gas) Good Good Good Up to 3% ketone Fair Fair Fair Up to 10% alcohol Good Good Fair Up to 3% synthetic lube Fair Fair Good 1. The NPS 6 / DN 150, 17E97 diaphragm will perform in gas temperatures as low as -20 F / -29 C. 2. For differential pressures above 400 psig / 28 bar diaphragm temperature is limited to 150 F / 66 C. 3. The aromatic hydrocarbon content is based on percent volume. Capacity Information Note Flow capacities are laboratory verified; therefore, regulators may be sized for flow published capacities. It is not necessary to reduce published capacities. Tables 13,14 and 15 show the natural gas regulating capacities of the EZR Series regulator at selected inlet pressures and outlet pressure settings. Flows are in thousands of SCFH at 60 F and 14.7 psia (and in thousands of Nm³/h at 0 C and bar) of 0.6 specific gravity natural gas. To determine equivalent capacities for air, propane, butane or nitrogen, multiply the capacity by the following appropriate conversion factor: for air, for propane, for butane or for nitrogen. For gases of other specific gravities, multiply the given capacity by and divide by the square root of the appropriate specific gravity. To find approximate regulating capacities at pressure settings not given in Tables 13, 14 and 15 or to find wide-open flow capacities for relief sizing at any inlet pressure, perform one of the following procedures. Then, if necessary, convert using the factors provided above. For critical pressure drops (absolute outlet pressure equal to or less than one-half of absolute inlet pressure), use the following formula: Q = (P 1 )(C g )(1.29) For pressure drops lower than critical (absolute outlet pressure greater than one-half of absolute inlet pressure). where, P Q = C g P 1 SIN DEG GT Q = gas flow rate, SCFH P 1 = absolute inlet pressure, psia (P 1 gauge ) C g = regulating or wide-open gas sizing coefficient from Table 9 or 10 G = gas specific gravity of the gas T = absolute temperature of gas at inlet, Rankine C 1 = flow coefficient P = pressure drop across the regulator, psi Then, if capacity is desired in normal cubic meters per hour at 0 C and bar, multiply SCFH by C 1 P 1 14
15 2 RUN Bulletin 71.2:EZR START EQUALIZER BYPASS MECHANISM BOX VALVE PLUG VALVE PLUG DISK B2692 INLET PRESSURE OUTLET PRESSURE LOADING PRESSURE MANOMETRIC DEVICE MANOMETRIC DEVICE STEM Figure 7. Type EZROSX with Slam-shut Device Operational Schematic Slam-Shut Device Principle of Operation The Type EZROSX with slam-shut device can provide either overpressure (OPSO) or overpressure and underpressure (OPSO/UPSO) protection by completely shutting off the flow of gas to the downstream system. The slam shut has a mechanism box and a manometric device. The manometric device is a spring and diaphragm actuator. Its movement activates the detection stage of the mechanism box. The shutoff is a two stage process, the detection stage and the power stage. This separation between detection stage and power stage provides maximum precision, alleviating many false trips caused by environmental vibrations. The slam-shut device includes a bypass valve that will allow pressure to be equalized when resetting the device. Once the slamshut device has been tripped, it must be manually reset. For more information about the Type EZROSX, contact your local Sales Office. 15
16 Table 7. Main Valve Maximum Pressure Ratings, Diaphragm Selection Information and Main Spring Selection (1) BODY SIZES DIAPHRAGM MATERIAL MAXIMUM OPERATING INLET PRESSURE (4) MAXIMUM OPERATING DIFFERENTIAL PRESSURE (4) MAXIMUM EMERGENCY INLET AND DIFFERENTIAL PRESSURE NPS DN psig bar psid bar d psid bar d 1 and 1-1/4 x 1 25 and 32 x 25 2 x 1 50 x , 6 x 4 and 8 x 4 6, 8 x 6 and 12 x 6 100, 150 x 100 and 200 x , 200 x 150 and x E68 Nitrile (NBR) Low temperature 17E97 Nitrile (NBR) Highpressure and/or erosion resistance 17E88 Fluorocarbon (FKM) High aromatic hydrocarbon content resistance 17E68 Nitrile (NBR) Low temperature 17E97 Nitrile (NBR) Highpressure and/or erosion resistance 17E88 Fluorocarbon (FKM) High aromatic hydrocarbon content resistance 17E68 Nitrile (NBR) Low temperature 17E97 Nitrile (NBR) Highpressure and/or erosion resistance 17E88 Fluorocarbon (FKM) High aromatic hydrocarbon content resistance 17E68 Nitrile (NBR) Low temperature 17E97 Nitrile (NBR) High-pressure and/or erosion resistance 17E88 Fluorocarbon (FKM) High aromatic hydrocarbon content resistance 17E68 Nitrile (NBR) Low temperature 17E97 Nitrile (NBR) High-pressure and/or erosion resistance 17E88 Fluorocarbon (FKM) High aromatic hydrocarbon content resistance 17E97 Nitrile (NBR) High-pressure and/or erosion resistance 17E88 Fluorocarbon (FKM) High aromatic hydrocarbon content resistance 17E97 Nitrile (NBR) High-pressure and/or erosion resistance MAIN SPRING COLOR Light Blue Black Black Black with White Stripe (2) Light Blue (3) 34 (3) Black (3) 34 (3) Black with White Stripe (2) Light Blue Black with White Stripe Black with White Stripe Red Stripe (2) Light Blue (3) Black with White Stripe Yellow Green Green Red or Purple (2) Yellow (3) 34 (3) Green (3) 34 (3) Red or Purple (2) Yellow Light Blue Light Blue Black (2) Yellow (3) 34 (3) Light Blue (3) 34 (3) Black (2) Yellow Green Green Red (2) Yellow (3) 34 (3) Green (3) 34 (3) Red (2) Yellow Green Red (2) Yellow (3) 34 (3) Green (3) 34 (3) Red (2) Yellow Green Red (2) DIAPHRAGM DESIGNATION 1. See Table 1 for main valve structural design ratings and Table 3 for pilot ratings. 2. The red, black, purple, red stripe and black with white stripe springs are only recommended for applications where the maximum inlet pressure can exceed 500 psig / 34.5 bar. 3. For differential pressures above 400 psid / 27.6 bar d diaphragm temperatures are limited to 150 F / 66 C. 4. These are recommendations that provide the best regulator performance for a typical application. Please contact your local Sales Office for further information if a deviation from the standard recommendations are required
17 Table 8. IEC Sizing Coefficients (1) MAIN VALVE BODY SIZE, NPS / DN X T F D F L 1 / / / / / / At capacity. Table 9. Main Valve Regulating Flow Coefficients (1) for EZR Series, With or Without Slam-Shut Device MAIN VALVE BODY SIZE, NPS / DN 1 / /4 x 1 / 32 x 25 2 x 1 / 50 x 25 2 / 50 3 / 80 4 / x 4 / 150 x x 4 / 200 x / x 6 / 200 x x 6 / x 150 CAGE STYLE, PERCENT OF CAPACITY LINE SIZE EQUALS BODY SIZE PIPING 2:1 LINE SIZE TO BODY SIZE PIPING With Inlet Strainer Without Inlet Strainer With Inlet Strainer Without Inlet Strainer C g C v C 1 C g C v C 1 C g C v C 1 C g C v C , , , , , , / , , , , K m for the NPS 1 / DN 25 body size at capacity is 0.88, the NPS 2 / DN 50 is 0.92, the NPS 3 / DN 80 is 0.94, the NPS 4 / DN 100 is 0.84 and the NPS 6 / DN 150 is , , , , , ,
18 Table 10. Main Valve Wide-Open Flow Coefficients for EZR Series, With or Without Slam-Shut Device MAIN VALVE BODY SIZE, NPS / DN 1 / /4 x 1 / 32 x 25 2 x 1 / 50 x 25 2 / 50 3 / 80 4 / x 4 / 150 x x 4 / 200 x / x 6 / 200 x x 6 / x 150 CAGE STYLE, PERCENT OF CAPACITY LINE SIZE EQUALS BODY SIZE PIPING 2:1 LINE SIZE TO BODY SIZE PIPING With Inlet Strainer Without Inlet Strainer With Inlet Strainer Without Inlet Strainer C g C v C 1 C g C v C 1 C g C v C 1 C g C v C , , , , , , / , , , , , , , , , ,760 8,500 4, Table 11. Pilot Flow Coefficients 161AY SERIES 161EB SERIES TYPE PRX Orifice Size C g C v C 1 Orifice Size C g C v C 1 C g C v C 1 3/32 in. / 2.4 mm 1/8 in. / 3.2 mm 1/4 in. / 6.4 mm /8 in. / 3.18 mm Table 12. Restrictor Flow Coefficients SET ON START SET ON RUN C 1 C g C v C g C v
19 Table 13. Capacities for EZR Series with Type 161AY or 161AYM Pilot INLET PRESSURE OUTLET PRESSURE CAPACITIES IN THOUSANDS OF SCFH / Nm³/h OF 0.6 SPECIFIC GRAVITY NATURAL GAS USING 1:1 LINE SIZE TO BODY SIZE PIPING WITHOUT INLET STRAINER NPS 1 / DN 25 NPS 2 / DN 50 NPS 3 / DN 80 NPS 4 / DN 100 NPS 6 / DN 150 NPS 8 / DN 200 psig bar psig bar SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h up to up to up to 6 7 up to up to up to up to 7 up to 0.48 up to 7 up to 0.48 up to 7 up to Note: Blank areas indicate where minimum main valve differential pressure is not met continued - Table 13. Capacities for EZR Series with Type 161AY or 161AYM Pilot (continued) INLET PRESSURE OUTLET PRESSURE NPS 1-1/4 x 1 / DN 32 x 25 CAPACITIES IN THOUSANDS OF SCFH / Nm³/h OF 0.6 SPECIFIC GRAVITY NATURAL GAS USING 1:1 LINE SIZE TO BODY SIZE PIPING WITHOUT INLET STRAINER NPS 2 x 1 / DN 50 x 25 NPS 6 x 4 / DN 150 x 100 NPS 8 x 4 / DN 200 x 100 NPS 8 x 6 / DN 200 x 150 NPS 12 x 6 / DN x 150 psig bar psig bar SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h up to up to up to 6 7 up to up to up to up to 7 up to 0.48 up to 7 up to 0.48 up to 7 up to Note: Blank areas indicate where minimum main valve differential pressure is not met
20 Table 14. Capacities for EZR Series with Type 161EB, 161EBM or PRX Pilot INLET PRESSURE OUTLET PRESSURE CAPACITIES IN THOUSANDS OF SCFH / Nm³/h OF 0.6 SPECIFIC GRAVITY NATURAL GAS USING 1:1 LINE SIZE TO BODY SIZE PIPING WITHOUT INLET STRAINER NPS 1 / DN 25 NPS 2 / DN 50 NPS 3 / DN 80 NPS 4 / DN 100 NPS 6 / DN 150 NPS 8 / DN 200 psig bar psig bar SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to 350 up to , , up to 350 up to , , up to 350 up to , , up to 350 up to , , Note: Blank areas indicate where minimum main valve differential pressure is not met ,630 10,519 10, ,331 11,697 10, ,726 14,593 13,989 13,217 17,121 16,892 16, continued - 20
21 Table 14. Capacities for EZR Series with Type 161EB, 161EBM or PRX Pilot (continued) INLET PRESSURE OUTLET PRESSURE NPS 1-1/4 x 1 / DN 32 x 25 CAPACITIES IN THOUSANDS OF SCFH / Nm³/h OF 0.6 SPECIFIC GRAVITY NATURAL GAS USING 1:1 LINE SIZE TO BODY SIZE PIPING WITHOUT INLET STRAINER NPS 2 x 1 / DN 50 x 25 NPS 6 x 4 / DN 150 x 100 NPS 8 x 4 / DN 200 x 100 NPS 8 x 6 / DN 200 x 150 NPS 12 x 6 / DN x 150 psig bar psig bar SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to up to ,438 10,365 10, ,438 10,365 10, up to up to ,136 12,009 11, ,136 12,009 11, up to 350 up to , up to 350 up to , , up to 350 up to , , up to 350 up to , , Note: Blank areas indicate where minimum main valve differential pressure is not met. 21
22 Table 15. Capacities for EZR Series with PRX Series INLET PRESSURE OUTLET PRESSURE CAPACITIES IN THOUSANDS OF SCFH / Nm³/h OF 0.6 SPECIFIC GRAVITY NATURAL GAS USING 1:1 LINE SIZE TO BODY SIZE PIPING WITHOUT INLET STRAINER NPS 1 / DN 25 NPS 2 / DN 50 NPS 3 / DN 80 NPS 4 / DN 100 NPS 6 / DN 150 NPS 8 / DN 200 psig bar psig bar SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h up to up to up to up to up to up to up to up to For outlet pressures above 435 psig / 30 bar, use Type PRX-AP pilot rather than Type PRX. Note: Blank areas indicate where minimum main valve differential pressure is not met ,751 10, ,202 11,640 10, ,651 13,396 12,679 11,604 10,000 15,096 14,510 13,650 12,420 15,932 15,398 14,618 13, ,697 10, ,593 13,989 12, ,381 16,892 15,526 13,435 10,055 19,697 18,574 16,938 14,547 10,809 22,008 21,486 20,133 18, 15,584 24,316 23,158 21,592 19,480 25,710 24,627 23,181 21,261 15, continued - 22
23 Table 15. Capacities for EZR Series with PRX Series (continued) INLET PRESSURE OUTLET PRESSURE NPS 1-1/4 x 1 / DN 32 x 25 CAPACITIES IN THOUSANDS OF SCFH / Nm³/h OF 0.6 SPECIFIC GRAVITY NATURAL GAS USING 1:1 LINE SIZE TO BODY SIZE PIPING WITHOUT INLET STRAINER NPS 2 x 1 / DN 50 x 25 NPS 6 x 4 / DN 150 x 100 NPS 8 x 4 / DN 200 x 100 NPS 8 x 6 / DN 200 x 150 NPS 12 x 6 / DN x 150 psig bar psig bar SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h SCFH Nm³/h ,365 10, ,365 10, ,274 12,009 11, ,274 12,009 11, up to up to ,931 13,289 12,253 10, ,931 13,289 12,253 10, up to up to ,584 15,294 14,475 13,247 11, ,584 15,294 14,475 13,247 11, up to up to ,235 16,566 15,584 14, ,235 16,566 15,584 14, up to up to ,189 17,579 16,688 15,432 11, ,189 17,579 16,688 15,432 11, For outlet pressures above 435 psig / 30 bar, use Type PRX-AP pilot rather than Type PRX. Note: Blank areas indicate where minimum main valve differential pressure is not met. 23
24 Table 16. Manometric Device Specifications (1) SPRING RANGE SPRING COLOR SPRING PART NUMBER MAXIMUM SENSING INLET PRESSURE MANOMETRIC SENSING DEVICE TYPE MANOMETRIC SENSING DEVICE STYLE SETPOINT TOLERANCE (1) MAXIMUM DIFFERENCE BETWEEN OVERPRESSURE AND UNDERPRESSURE (2) psig bar psig bar psig bar psig bar 4.02 to 14.1 in. w.c to 33.2 in. w.c. 10 to 35 mbar Purple T14232T to 83 mbar Orange T14233T in. w.c. to 45 mbar to Red T14234T psig 0.14 bar to to 0.24 Yellow T14235T to to 0.38 Green T14236T0012 Diaphragm to to 0.75 Gray T14238T to to 1.3 Brown T14239T to to 2.3 Black T14240T to to 5.1 Blue T14237T to to 11.0 Brown T14239T to to 16.0 Black T14240T to to 22.0 Brown T14239T to to 40.0 Black T14240T Piston 588 to to 55.0 Brown T14239T to to 100 Black T14240T Requires use of Types BMS1 and BMS2 81 to to 22.0 Brown T14239T to to 35.0 Black T14240T0012 Bellows to to 72.0 Gray T14238T Minimum suggested difference between slam-shut set pressure and normal operating pressure of the system. 2. Maximum difference between overpressure and underpressure when using one manometric device (Type BMS1) with tripping hook. For underpressure and overpressure points greater than this maximum number, use a second manometric device (Type BMS2) for underpressure protection. Table 17. Applications and Construction Guide (See Figure 9) APPLICATION Overpressure Shutoff (OPSO) Underpressure Shutoff (UPSO) Overpressure Shutoff (OPSO) and Underpressure Shutoff (UPSO) Overpressure Shutoff (OPSO) and Underpressure Shutoff (UPSO) Overpressure Shutoff (OPSO), Overpressure Shutoff (OPSO) and Underpressure Shutoff (UPSO) MECHANISM BOX REQUIRED MANOMETRIC SENSING DEVICE REQUIRED Type BM1 Type BM2 Type BMS1 Type BMS2 Yes No No Yes Yes Yes (1) Yes (2) No Yes Yes (2) Yes (1) 1. When using one manometric sensing device (Type BMS1 or BMS2) for both overpressure and underpressure shutoff, make sure that the difference between set pressures falls within the maximum range shown in Table When using two manometric sensing devices (Type BMS1 and a Type BMS2), the Type BMS1 can only be used for high trip. 24
25 TYPE BM1 TYPE BM2 FRANCEL FRANCEL TYPE BMS1 TYPE BMS1 (RIGHT SIDE) E0564 FRANCEL BMS2 (LEFT SIDE) FRANCEL E0565 MECHANISM BOX (TYPE BM1) WITH 1 MANOMETRIC SENSING DEVICE (TYPE BMS1) MECHANISM BOX (TYPE BM2) WITH 2 MANOMETRIC SENSING DEVICES (TYPES BMS1 AND BMS2) Figure 8. Types of Installation (Mounting on Horizontal Pipeline Only) MECHANISM BOX FIRST-STAGE RESET PIN (WHITE) SETPOINT ADJUSTMENT RING SECOND-STAGE RESET SHAFT TRAVEL STOP Figure 9. Slam-Shut Device in Open Position Figure 10. Slam-Shut Device in Closed Position Table 18. Approximate Weights Including 161EB Series, 161AY Series, PRX Series Pilot and Restrictor (1)(2) BODY SIZES, NPS / DN 1 and 1-1/4 / 25 and 32 2 and 2 x 1 / 50 and 50 x 25 3 / 80 CAST IRON MAIN VALVE BODY, lbs / kg NPT CL125 FF CL RF NPT, SWE or BWE WCC OR LCC STEEL MAIN VALVE BODY, lbs / kg WITH INTEGRAL SLAM SHUT, lbs / kg CL150 RF CL RF CL600 RF CL150 RF CL RF CL600 RF 22 / / / / / / / / / / / / / /29 86 / / / / / / / / / / / / 70 4 / / / / / / / / / / x 4 / 150 x / / / / x 4 / 200 x / / / / / / / / / / / / / / x 6 / 200 x / / / / x 6 / x / / / / / / / / Add an additional 15 lbs / 7 kg to get the weight with a 161AY Series pilot. 2. Add an additional 5 lbs / 2 kg to get the weight of PRX Series pilot. 25
26 RESTRICTOR PILOT SUPPLY FILTER PILOT CONTROL LINE BLOCK VALVE BLOCK VALVE HAND VALVE SLAM-SHUT DEVICE HAND VALVE B2681 CONTROL LINE ALTERNATE CONTROL LINE 11A Overpressure and Underpressure Shutoff Using One Manometric Device (This Application Might Require Two Manometric Devices As Shown In Figure 11C) RESTRICTOR PILOT SUPPLY FILTER PILOT CONTROL LINE BLOCK VALVE BLOCK VALVE HAND VALVE SENSE LINE HAND VALVE B2682 SLAM-SHUT DEVICE CONTROL LINE ALTERNATE CONTROL LINE 11B Minimum and Maximum Upstream and Downstream Pressure RESTRICTOR PILOT SUPPLY FILTER PILOT CONTROL LINE BLOCK VALVE BLOCK VALVE HAND VALVE SLAM-SHUT DEVICE HAND VALVE B2683 CONTROL LINES HAND VALVE 11C Overpressure and Underpressure Shutoff Using Separate Manometric Devices ALTERNATE CONTROL LINE Figure 11. Type EZROSX with Integral Slam-Shut Device Installation Schematics 26
27 RESTRICTOR PILOT SUPPLY FILTER PILOT CONTROL LINE BLOCK VALVE UPSTREAM BLOCK VALVE HAND VALVE SLAM-SHUT DEVICE HAND VALVE B2684 EXTERNAL TRIP PRESSURE 13D External Signal CONTROL LINE CONTROL LINE RESTRICTOR RESTRICTOR PILOT SUPPLY FILTER PILOT PILOT SUPPLY FILTER PILOT HAND VALVE BLOCK VALVE EXHAUST PIPING BLOCK VALVE HAND VALVE SLAM-SHUT DEVICE HAND VALVE B2685 CONTROL LINE 11E Wide-Open Monitoring System with Slam-Shut Device for Overpressure and Underpressure Shutoff Using One Manometric Device (This Application Might Require Two Manometric Devices As Shown In Figure 11F) CONTROL LINE RESTRICTOR MONITOR PILOT RESTRICTOR PILOT SUPPLY FILTER WORKING PILOT PILOT SUPPLY FILTER PILOT HAND VALVE BLOCK VALVE EXHAUST PIPING BLOCK VALVE HAND VALVE SLAM-SHUT DEVICE HAND VALVE B2685 CONTROL LINE HAND VALVE 11F Working Monitoring System with Slam-Shut Device for Overpressure and Underpressure Shutoff Using Two Manometric Devices (This Application Might Only Require One Manometric Device As Shown In Figure 11E) Figure 11. Type EZROSX with Integral Slam-Shut Device Installation Schematics (continued) 27
28 1/4 NPT UPSTREAM INLET (SUPPLY) CONNECTION A V-TRIM REMOVAL CLEARANCE F E C 3.25 / 83 A/ / 106 B2482 3/4 NPT DOWNSTREAM CONTROL LINE CONNECTION D TYPE EZR WITH 161AY SERIES PILOT 3.00 / 76 CAP REMOVAL CLEARANCE E TRAVEL INDICATOR COVER REMOVAL CLEARANCE C E F MAIN VALVE TRIM REMOVAL CLEARANCE G 161EB SERIES 1/4 NPT DOWNSTREAM CONTROL CONNECTION V TYPE 112 1/4 NPT UPSTREAM SUPPLY CONNECTION B2483 A/2 IN. / mm Figure 12. Typical EZR Dimensions TYPE EZR WITH 161EB SERIES PILOT Table 19. Typical EZR Dimensions BODY SIZE, In. / DN 1, 1-1/4 / 25, 32 2, 2X1 / 50, 50X25 SWE NPT 8.25 / / / 80 4 / 100 6X4 / 150X100 8X4 / 200X100 6 / 150 8X6 / 200X150 12X6 / X150 8 / FF 150RF 7.25 / / / / / / / / / / 543 RF RF 7.75 / / / / / / / / / / 568 DIMENSIONS, In. / mm A E F 600RF BWE 8.25 / / / / / / / / / / 610 C D 161AY 161EB PRX 161AY 161EB PRX 2 / 51 2 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 9.86 / 9.86 / 14.5 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 392 G 8.67 / / / / / / / / / / 522 V 8 / / / / / / / / / /
29 TYPE 162 TYPE 71 Ø 6.75 / / 93 Ø 2.81 / / 64 DIAPHRAGM BMS TYPE 27 TYPE 17 Ø 2.82 / 72 Ø 2.82 / 72 D H Y 4.82 / 122 PISTON BMS 2.82 / 72 TYPE 236 TYPE / 25 TYPE BMS / / 83 TYPE BMS / 121 Ø 2.92 / / 90 Ø 2.93 / 74 MECHANICAL BOX REMOVAL CLEARANCE BELLOWS BMS IN. / mm 19B8970 TYPE EZROSX WITH 161AY SERIES PILOTS AND TYPE 252 FILTER Figure 13. Typical EZROSX Dimensions Table 20. Typical EZROSX Dimensions DIMENSION, In. / mm BODY SIZE, In. / DN H D Y 1 / / / / 262 2, 2X1 / 50, 50 X / / / / / / / / / / / / / / /
30 Ordering Information The precision slotted cage of the EZR Series regulator offers superior noise attenuation. For a standard installation, as well as to obtain a noise prediction for your installation and service conditions, please complete the specifications worksheet at the bottom of the ordering guide on page 32. Carefully review each specification, then complete the Ordering Guide on pages 30 and 31. If a pilot setpoint is not requested, the regulator will be factory set at the approximate midrange. Type EZR Ordering Guide Type (Select One) EZR EZROSX (with slam shut) Body Size (Select) NPS 1 / DN 25 (Available in steel only)*** NPS 1-1/4 x 1 / DN 32 x 25 (Available in NPT steel only)*** NPS 2 / DN 50*** NPS 2 x 1 / DN 50 x 25*** NPS 3 / DN 80*** NPS 4 / DN 100*** NPS 6 x 4 / DN 150 x 100*** NPS 8 x 4 / DN 200 x 100*** NPS 6 / DN 150*** NPS 8 x 6 / DN 200 x 150*** NPS 12 x 6 / DN x 150*** NPS 8 / DN 200*** Body Material and End Connection Style (Select One) (NPS 8 / DN 200 size available only in LCC steel CL150, CL or CL600 RF) Cast Iron Body NPT (Available in NPS 2 or 2 x 1 / DN 50 or 50 x 25 only)*** CL125 FF*** CL RF*** WCC or LCC Steel Body NPT (Available in NPS 1, 1-1/4 x 1, 2 x 1 or 2 / DN 25, 32 x 25, 50 x 25 or 50 only)*** CL150 RF*** CL RF*** CL600 RF*** SWE (Available in NPS 1, 2 x 1 or 2 / DN 25, 50 x 25 or 50 only)* BWE 40** BWE 80* PN 16/25/40* specify Main Valve Diaphragm Material (Select One) 17E68 Nitrile (NBR) (low temperature) (Not available on NPS 6 or 8 / DN 150 or 200 size)*** 17E97 Nitrile (NBR) (high-pressure/ erosion resistance)*** 17E88 Fluorocarbon (FKM) (high aromatic hydrocarbons) (Not available on NPS 8 / DN 200 size)** Cage, Percent of Full Capacity (Select One) 100 percent (standard)*** 60 percent (Not available on 8 / DN 200 size)*** 30 percent (Not available on 8 / DN 200 size)*** Main Valve O-ring Material (Select One) Nitrile (NBR) (standard)*** Fluorocarbon (FKM)** Main Valve Main Spring (See Table 7 for Maximum Inlet Rating) (Select One) NPS 1, 1-1/4 or 2 x 1 / DN 25 or 50 x 25 Main Valve Light Blue*** Black*** Black with white stripe*** Red Stripe*** NPS 2 / DN 50 Main Valve Yellow*** Green*** Red*** Purple NPS 3 / DN 80 Main Valve Yellow*** Light Blue*** Black*** NPS 4, 6 x 4 or 8 x 4 / DN 100, 200 x 150 or x 150 Main Valve Yellow*** Green*** Red*** NPS 6, 8 x 6 or 12 x 6 / DN 150, 200 x 150 or x 150 Main Valve Yellow*** Green*** Red*** NPS 8 / DN 200 Main Valve Yellow*** Green*** Red*** Travel Indicator (Select One) No (standard)*** Yes*** 30
31 Type EZR Ordering Guide (continued) Inlet Strainer (Select One) No (standard)*** Yes*** Inlet Body Tap (Select One) Inlet body tap only (standard)*** Inlet body tap with pre-piped pilot supply*** Inlet/outlet body taps only*** Inlet/outlet body taps with pre-piped pilot supply and pilot bleed*** Pilot Diaphragm Material (Select One) Nitrile (NBR) (standard)*** Fluorocarbon (FKM)** Pilot O-ring Material (Select One) Nitrile (NBR) (standard)*** Fluorocarbon (FKM)*** Pilot Valve Plug Material (Select One) Nitrile (NBR) (standard)*** Fluorocarbon (FKM)*** Pilot Type and Outlet Pressure Range (Select One) Type 161AY 6 to 15 in. w.c. / 15 to 37 mbar, Olive Drab*** 0.5 to 1.2 psig / 0.03 to 0.08 bar, Yellow*** 1.2 to 2.5 psig / 0.08 to 0.17 bar, Light Green*** 2.5 to 4.5 psig / 0.17 to 0.31 bar, Light Blue*** 4.5 to 7 psig / 0.31 to 0.48 bar, Black*** Type 161AYM 6 to 15 in. w.c. / 15 to 37 mbar, Olive Drab*** 0.5 to 1.2 psig / 0.03 to 0.08 bar, Yellow*** 1.2 to 2.5 psig / 0.08 to 0.17 bar, Light Green*** 2.5 to 4.5 psig / 0.17 to 0.31 bar, Light Blue*** 4.5 to 7 psig / 0.31 to 0.48 bar, Black*** Type 161EB 5 to 15 psig / 0.34 to 1.0 bar, White*** 10 to 40 psig / 0.69 to 2.8 bar, Yellow*** 30 to 75 psig / 2.1 to 5.2 bar, Black*** 70 to 140 psig / 4.8 to 9.7 bar, Green*** 130 to 200 psig / 9.0 to 13.8 bar, Blue*** 30 to psig / 2.1 to 20.7 bar, Green*** (intermediate reduction pilot on the Type EZR worker/monitor systems) 200 to 350 psig / 13.8 to 24.1 bar, Red*** Type 161EBM 5 to 15 psig / 0.34 to 1.0 bar, White*** 10 to 40 psig / 0.69 to 2.8 bar, Yellow*** 30 to 75 psig / 2.1 to 5.2 bar, Black*** 70 to 140 psig / 4.8 to 9.7 bar, Green*** 130 to 200 psig / 9.0 to 13.8 bar, Blue *** 200 to 350 psig / 13.8 to 24.1 bar, Red*** Type PRX120/ to 26 psig / 1.00 to 1.8 bar, Yellow*** 23 to 44 psig / 1.6 to 3.0 bar, Green*** 41 to 80 psig / 2.8 to 5.5 bar, Blue*** 73 to 123 psig / 5.0 to 8 bar, Black*** 116 to 210 psig / 8 to 14 bar, Silver*** 203 to 334 psig / 14 to 23 bar, Gold*** 319 to 435 psig / 22 to 30 bar, Aluminum*** Type PRX120/125-AP 435 to 1000 psig / 30 to 69 bar, Clear*** Type 252 Pilot Supply Filter (Optional) Material Stainless steel*** Aluminum** Length Standard*** Extended** Drain Valve Yes*** No** Conversion Trim Package (Optional, Not available for NPS 8 / DN 200 size) Yes, send one conversion trim package. (If ordering replacement trim package for change-out of existing E-body to a Type EZR, be sure to mark selection of the following items on this page: body size, diaphragm material, inlet strainer option and travel indicator option desired.) Main Valve Replacement Parts Kit (Optional) Yes, send one diaphragm cartridge and O-rings kit to match this order. Yes, send one diaphragm and O-rings kit to match this order. Pilot Replacement Parts Kit (Optional) Yes, send one replacement kit to match this order. Wireless Position Monitor Mounting Kit (Optional) Yes, send one mounting kit for mounting the Topworx 4310 or the Fisher 4320 wireless position monitor (requires Travel Indicator option) 31
32 Type EZR Ordering Guide (continued) Specification Worksheet Application (Please designate units): Specific Use Line Size Gas Type and Specific Gravity Gas Temperature Does the Application Require Overpressure Protection? Yes No If yes, which is preferred: Relief Valve Monitor Regulator Shutoff Device Is overpressure protection equipment selection assistance desired? Regulators Quick Order Guide * * * Readily Available for Shipment * * Allow Additional Time for Shipment * Special Order, Constructed from Non-Stocked Parts. Consult your local Sales Office for Availability. Availability of the product being ordered is determined by the component with the longest shipping time for the requested construction. Pressure: Maximum Inlet Pressure (P 1max ) Minimum Inlet Pressure (P 1min ) Downstream Pressure Setting(s) (P 2 ) Maximum Flow (Q max ) Performance Required: Accuracy Requirements? Need for Extremely Fast Response? Other Requirements: Industrial Regulators Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas USA Tel: Outside U.S Asia-Pacific Shanghai , China Tel: Europe Bologna 40013, Italy Tel: Middle East and Africa Dubai, United Arab Emirates Tel: Natural Gas Technologies Emerson Process Management Regulator Technologies, Inc. USA - Headquarters McKinney, Texas USA Tel: Outside U.S Asia-Pacific Singapore , Singapore Tel: Europe Bologna 40013, Italy Tel: Chartres 28008, France Tel: Middle East and Africa Dubai, United Arab Emirates Tel: TESCOM Emerson Process Management Tescom Corporation USA - Headquarters Elk River, Minnesota , USA Tels: Europe Selmsdorf 23923, Germany Tel: Asia-Pacific Shanghai , China Tel: For further information visit The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser. Emerson Process Management Regulator Technologies, Inc., 1999, 2015; All Rights Reserved
Type EZR Relief Valve or Backpressure Regulator
October 2015 Type EZR Relief Valve or Backpressure Regulator Internally Actuated quiet Operation Exceptional Design Thoroughly Tested Robust Construction NPS 1, 2, 3, 4, 6 and 8 / DN 25, 50, 80,, 150 and
Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications
Type EZL Pressure Reducing Regulator for Low Differential Pressure Applications May 2016 W8962 Figure 1. Type EZL Pressure Reducing Regulator Features Main Diaphragm The main diaphragm is Nitrile (NBR)
Types 66R and 66RR Low-Pressure Relief Valves
November 2009 Types 66R and 66RR Low-Pressure Relief Valves W1953 W1908 TYPE 66R RELIEF VALVE TYPE 66RR RELIEF VALVE Figure 1. Typical Constructions Introduction Types 66R and 66RR low-pressure throttling
1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
289 Series Spring-Loaded Relief Valves
October 14 89 Series Spring-Loaded Relief Valves W187_1 W1871 TYPE 89L 1 NPT TYPES 89H AND 89HH W187 NPT TYPE 89H W187_ TYPES 89U AND 89A Figure 1. Types 89H, 89L and 89U Relief Valves Introduction The
Type 99 Pressure Reducing Regulator
Bulletin 7: February 2016 Type Pressure Reducing Regulator W27 W76 Figure 1. Typical Type Regulator Introduction The Type gas regulators provide a broad capacity for controlled pressure ranges and capacities
1301 Series High-Pressure Regulators
1301 Series High-Pressure Regulators Bulletin 71.1:1301 December 2013 P10 Figure 1. Type 1301F Regulator Features Durable Stainless Steel Diaphragm For high-outlet pressure applications. Spare Valve Disk
167D Series Switching Valves
June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are
Type 92S Pilot-Operated Steam Regulator
Type 92S Pilot-Operated Steam Regulator Introduction The Type 92S steam regulator is piston actuated for high cycle steam service which includes a Type 6492L, 6492H or pilot (see Figure 1). These pilots
Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications
Instruction Manual Form 5753 Type HSR February 014 Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications P154 TYPE HSR ANGLE BODY P175 TYPE HSR STRAIGHT Figure 1.
Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator
Instruction Manual Form 5351 Type 310A March 2010 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator! Warning Failure to follow these instructions or to properly
Type 99 Pressure Reducing Regulator
Instruction Manual Form 589 Type 99 February 2016 Type 99 Pressure Reducing Regulator! WARNINg Since a pilot-operated regulator is constructed of both a pilot and a main valve, care should be used not
Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology
Vacuum Applications Vacuum regulators and breakers are widely used in process plants. Conventional regulators and relief valves might be suitable for service if applied correctly. This section provides
Type 119 Control Valve
Instruction Manual Form 5204 Type 119 December 2009 Type 119 Control Valve Introduction Scope of the Manual This instruction manual provides installation, spring adjustment, maintenance, and parts information
1800C and 1800C-HC Series Service Regulators. Technical Bulletin
and -H Series Service Regulators Technical Bulletin and -H Series Service Regulators 0 Elster American Meter The Series pressure regulators are designed to control natural gas, air, nitrogen, carbon dioxide,
67C Series Instrument Supply Regulators
Instruction Manual Form 5469 67C Series May 2014 67C Series Instrument Supply Regulators W7412 W8438 Type 67CF Filter Regulator with Optional Gauge Type 67C or 67CR Regulator Figure 1. 67C Series Regulators
Principles of Direct-Operated Regulators
Principles of Direct-Operated Regulators Introduction Pressure regulators have become very familiar items over the years, and nearly everyone has grown accustomed to seeing them in factories, public buildings,
Baumann 24003 3 Way Bronze or Stainless Steel Control Valve
Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3
SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM
SLAM-SHUT VALVE Type OSE Process Management TM DESCRIPTION The purpose of the OSE slam shut valve is to totally and rapidly cut off gas flow when the outlet pressure exceeds or drops below the setting.
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
Fisher CV500 Rotary Globe Control Valve
CV500 Valve D101606012 Product Bulletin Fisher CV500 Rotary Globe Control Valve The Fisher CV500 Cam Vee-Ball control valve combines the rangeability of the cammed-segmented V-notched ball, with the inherent
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features
Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
Baumann 24000 Little Scotty Bronze Control Valve
24000 Valve Product Bulletin Baumann 24000 Little Scotty Bronze Control Valve Baumann Little Scotty industrial control valves are intended for general utility service in pressure, flow, and temperature
MODEL 201 225LP 225LP2 225LP4 Safety Relief Valves
Edition GDRV.06 BRYAN DONKIN RMG CANADA LIMITED Serving the Gas Industry WORLDWIDE Applications Specifically designed to protect the downstream system or equipment from over pressure conditions by discharging
S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR
MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,
The Axial Flow Valve. Class 300/600. [email protected] www.elster-instromet.com SERIES
The Axial Flow Valve SERIES Class 300/600 [email protected] www.elster-instromet.com THE AXIAL FLOW VALVE - SERIES 300/600 A UNIQUE REGULATOR What is the Axial Flow Valve? The Axial Flow Valve
TECHNICAL DATA. Dry 122a. November 12, 2013
Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model
Baumann 81000 Mikroseal Control Valve
Product Bulletin D103340X012 Baumann 81000 Mikroseal Control Valve The Baumann 81000 Mikroseal control valve (figures 1 and 2) is excellent for throttling of liquid or gaseous media, particularly where
PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM
PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM PRESSURE REDUCER AND RELIEF VALVES These devices are used to reduce and control a gaseous flow pressure (air, steam, gas ). The PRESSURE
DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for
Fisher 377 Trip Valve
377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls
5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...
Commercial & Industrial Propane Regulators and Meters
Commercial & Industrial Propane Regulators and Meters Master Distributor for First Stage Regulators P32* Field adjustable 60 Mesh screen on inlet 1/4 FNPT 250 PSI Excellent stability P37* Patented balance
Fisher 377 Trip Valve
Instruction Manual Fisher 377 Trip Valve Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 2 Educational Services... 2 Installation... 4 Supply Pressure Requirements...
Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)
OPTIONS: USE: AVAILABLE MODELS: Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel) DESCRIPTION The ADCA PRV47 pilot operated pressure reducing valves are designed for use on steam,
Fisher 657 and 667 Diaphragm Actuators
657 and Actuators Product Bulletin Fisher 657 and Diaphragm Actuators Fisher 657 and spring-opposed diaphragm actuators position the valve plug in the valve in response to varying controller or valve positioner
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
Proportional Relief Valves
www.swagelok.com Proportional Relief Valves R Series Liquid or gas service Set pressures from 10 to psig (0.7 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections 2 Proportional Relief Valves Spring
API Flanged Safety Relief Valves Series 526 CATALOG
API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes
CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.
CHAPTER II REGULATOR AND RELIEF DEVICES This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192. BASIC CONCEPT In understanding
Baumann 87000 Flexsleev Sanitary Control Valve
Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found
Fisher 8580 Rotary Valve
8580 Valve Product Bulletin Fisher 8580 Rotary Valve The Fisher 8580 rotary valve offers excellent throttling and automated on-off, quarter-turn performance. An approximately linear flow characteristic
GS-General Service Control Valves
GS-General Service Control Valves GS-General Service Valves The GS-General Service Valves continue Copes-Vulcan s tradition of designing and manufacturing control valves that provide both exceptional service
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
Fisher D3 Control Valve
D3 Valve Product Bulletin Fisher D3 Control Valve The Fisher D3 control valve is a compact, rugged valve designed for on/off or throttling control, and utilizes FloPro technology, using either pneumatic
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description
Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed
ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.
ASME/ANSI B16.1-1998 - Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B16.3-1998 - Malleable Iron Threaded Fittings ASME/ANSI B16.4-1998 - Cast Iron Threaded Fittings ASME/ANSI B16.5-1996 - Pipe
BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features
Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,
Fisher 2625, 2625SST, and 2625NS Volume Boosters
Instruction Manual 2625, 2625SST, and 2625NS Volume Booster Fisher 2625, 2625SST, and 2625NS Volume Boosters Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Educational
BERMAD Fire Protection
400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad
3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide
", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,
PRESSURE REGULATOR SERIES 2100-4100 - 5100 R 4100 R 2100 R 5100 VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR BALANCED VALVE HIGH FLOW COEFFICIENT
VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR BALANCED VALVE HIGH FLOW COEFFICIENT PRESSURE REGULATOR WIDE PRESSURE-REGULATION RANGE CAN BE SUPPLIED WITH MINIMUM / MAXIMUM PRESSURE SLAM-SHUT VALVE R 4100 POSSIBILITY
AIR LINE VALVES AND GAUGES
AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand
Shut-off & Lockout Valves 1/4" to 1-1/2" port size
Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout
Installation, Operation and Maintenance Manual for Pilot Operated Valves
Installation, Operation and Maintenance Manual for Pilot Operated Valves Models 1400, 1420, 1430, 1460 IOM1400.0 January 2, 2014 REV A 12393 REF. ID 98136 IOM1400.0 REV. A 12541 TABLE OF CONTENTS DESCRIPTION
Contents. LWN 750.30 edition: 24.02.10 3-0
Contents 3.1 Introduction...3.1-1 3.2 List of Referenced Codes and Standards...3.2-1 3.3 Overview Terms and Definitions...3.3-1 3.4 Description Terms and Definitions...3.4-1 LWN 750.30 edition: 24.02.10
Fisher GX Control Valves
Fisher GX Control Valves Fisher GX Control Valves Innovation. Technology. Reliability. Emerson engineers started with a clean slate in developing Fisher GX control valves. Their goal was to bring unmatched
61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve
61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve Features Rounded polished disc edge gives full concentric sealing, lower torques, longer seat life
Select the Right Relief Valve - Part 1 Saeid Rahimi
Select the Right Relief Valve - Part 1 Saeid Rahimi 8-Apr-01 Introduction Selecting a proper type of relief valve is an essential part of an overpressure protection system design. The selection process
Baumann 24000SB Barstock Control Valve
Instruction Manual 24000SB Valve Baumann 24000SB Barstock Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 3 Installation... 3 Air Piping... 4 Disassembly...
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
REGULATORS D& HD Series
Watson McDaniel reserves the right to change the designs and/or materials of its products out notice. 2002 Watson McDaniel Company Ductile Iron body - HD Series Full port strainer & blowdown valve on pilot
BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications
series 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N
Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM ISO 9 No. CLEFFI / GB replaces / GB Function Pressure reducing valves are devices which, when installed
Installation, Maintenance, & Repair Series 4000B/LF4000B
Installation, Maintenance, & Repair Series 4000B/LF4000B Reduced Pressure Zone Assemblies Sizes: 1 2" 2" (15 50mm) RP/IS-A-4000B 4000B/LF4000B Size: 3 /4"! WARNING Testing Read this Manual BEFORE using
Mechanical shaft seal types and sealing systems
Chapter 2 Mechanical shaft seal types and sealing systems 1. Mechanical shaft seal types 2. Sealing systems 3. Selecting a mechanical shaft seal Mechanical shaft seal types and sealing systems 1. Mechanical
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24
Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical
Automatic Self-Cleaning Strainers
Applications Water and Liquid service Power Industry Cooling water Pulp & Paper Removing fibers Process Equipment Protect equipment Metal & Mining Quenching, blast furnace cooling Automatic Self-Cleaning
Ball Valves (HB Series) Catalog 4121-HB Revised, April 2005
Ball Valves (HB Series) Revised, April 2005 Introduction Parker High Pressure HB4 Series Ball Valves provide reliable shut-off or switching functions. The upper and lower trunnion bearings enhance the
BM5 SERIES SLAM SHUT VALVES
BM5 SERIES SLAM SHUT VALVES Axial flow slam shut valve with sleeve valve and manual reset Introduction BM5 series slam shut valve is an automatic shut-off appliance suitable for installation as safety
Multipurpose Ball Valves
www.swagelok.com Multipurpose Ball Valves 33 Series Working pressures up to 6000 psig (413 bar) High flow capacity in a compact design Available with PEEK and UHMWPE seats Variety of end connections Low
Air Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
QLM and QLD Series Three-port Control Valves
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering
Model: 400E-2M Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Application Engineering BERMAD 1. Safety First BERMAD believes that the safety
In-Line Air Separators
Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 [email protected] www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
BERMAD Fire Protection
Model: 400E-2M BERMAD Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with and around
VAG Non-Return Valves
VAG Non-Return Valves VAG SKR Slanted Seat Tilting Disk Check Valve Body Shaft Disk Bearing bush Seat Technical details Nominal pressure PN 10 / PN 16 Nominal diameter DN 200...1200 Fields of application:
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:
Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees
WD600 STEAM TRAPS. Thermodynamic Steam Trap
WD600 Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company WD600, WD600L Sizes 3/8, 1/2, 3/4, 1 NPT Material Stainless
Signature and ISX CM870 Fuel System
Signature and ISX CM870 Fuel System Cummins Ontario Training Center HPI-TP Fuel System Heavy Duty High Pressure Injection - Time Pressure Fuel System The fuel system developed for the Signature and ISX
Pipe Valves, Fittings and Nipples Pressures to 15,200 psi
Pipe Valves, Fittings and Nipples MAXIMATOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed by
Powers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
Pressure Relief and Regulating Valves
Pressure Relief and Regulating Valves With blocked center directional valves and variable displacement pumps, or open center directional valves and fixed displacement pumps where fast response, low leakage
Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.
DAN-LIQ-TG-44-rev0208 February 2008 Daniel Liquid Control Valves Technical Guide www.daniel.com Daniel Measurement and Control Theory, Principle of Operation and Applications This brochure has been prepared
2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
Powers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
CHEXTER TM FITS YOUR APPLICATION, PROFITABLY
CHEXTER TM FITS YOUR APPLICATION, PROFITABLY Commercial Construction CHEXTER TM Check Valves are economically used in chilled and hot water air conditioning systems, refrigeration and other piping and