Transformer Disconnect - NEMA 1 / IP22 APFB-ABB Series

Similar documents
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Secondary Unit Substations

Distribution Dry Type Transformers

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

8146/5 Series Breaker Panelboards

MAJORSINE Power Inverter

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

SURGE PROTECTIVE DEVICES

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Mini Power-Zone Unit Substation

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Circuit Breakers. Next Generation of Protection Capabilities

SECTION VARIABLE FREQUENCY DRIVES

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Mission Critical Data Center Systems

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Specifications. Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT:

Thyristor-controlled power supplies and battery chargers

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Uninterruptible Power Supply

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

How To Test A Power Switch On A Power Supply

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

Rotary Disconnect Switch Specifications

Safety technique. Emergency stop module BO 5988 safemaster

Short-circuit current rating (SCCR) of. industrial control panels. NEC Article 409 and UL 508A

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

Actuator-Sensor-Interface

Analog Servo Drive 25A8

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings

Buck - Boost Transformers

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

GTEC transfer switch open transition

ASCO SERIES 185 Power Transfer Switches

Siemens STEP 2000 Course Basics of Electrical Products

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Power Supplies 3. SDN-P DIN Rail Series

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

Applications. Remote Display Mounting Kits

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Power surges can also be generated by equipment in your facility such as:

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

Modan 3000 ADVANCED TECHNOLOGY, INDUSTRIAL GRADE MOTOR CONTROL CENTER. Systems Products and Services. Motor Control Centers Modan 3000

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

Power Management Module 2. Installation

Bulletin 150 SMC Flex Smart Motor Controller Specifications

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

Engineers Edge, LLC PDH & Professional Training

Variable Transformers Product Design & Engineering Data

Surge Protection for Photovoltaic Systems

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

Generator DoCKInG StatIonS

A sophisticated design for a demanding field. prima series

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

NetScanner System. Toronto: , Montreal: , Toll Free: ,

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PowerFlex 700 and 700H Packaged Drives. Technical Data

Industrial Control Power Transformers

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

MCC Ratings. Voltage Rating

Glossary of Common Crane Ter ms:

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

Model #: SMART2200CRMXL

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

6 Buck Boost Transformers

Arc Terminator Active Arc-Resistant Switchgear

Class 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Transcription:

Disconnect - NEMA 1 / IP22 APFB-ABB Series Low Profile Flange Mounted Switch (0.5 kva - 3 kva) The Daykin APFB-ABB is suitable for applications ranging from 0.5 kva - 3 kva. It features a flange mounted disconnect switch. This NEMA 1 enclosure features louvers to allow for thermal dissipation for use within relatively shallow control panel enclosures. Lockable switch in the off position with primary integral CLASS CC fuses Electrostatically shielded transformer provides positive protection against short circuits from the primary to the secondary, as well as attenuating high frequency noise and transients Flange mounted disconnect switch with visible blade construction, lockable in the off position with up to three (3) padlocks 0.5 APFB-ABB-0.5 3 6 60 (27) 1.0 APFB-ABB-1 6 12 65 (29) 2.0 APFB-ABB-2 12 25 78 (35) 3.0 APFB-ABB-3 20 30 93 (42) 1

Disconnect - NEMA 1 / IP22 APFB Series Low Profile ( 2 kva - 3 kva ) The Daykin APFB Series is suitable for use on circuits capable of delivering 200,000 A RMS symmetrical short circuit current to meet the most stringent Canadian and USA requirements. This NEMA 1 enclosed assembly features an overall depth of 7.88 for use within relatively shallow control panel enclosures. 200kA RMS short circuit current rating Lockable switch in the off position with primary integral CLASS CC fuses Electrostatically shielded transformers An overall depth of 7.88 for use with relatively shallow control panel enclosures 2.0 APFB-2 12 25 53 (24) 3.0 APFB-3 15 30 80 (36) 2

Disconnect - NEMA 1 / IP22 CVFB Series Constant Voltage (1 kva - 5 kva) The Daykin CVFB Series offers a powerful combination of transformer disconnect with a surge-suppressed regulated voltage output tailored to the specific power needs of PLC, computer based controls and other voltage and noise sensitive equipment. The 200 ka SCCR exceeds the most stringent UL 508A & Canadian requirements. This provides a higher level of protection in the case of catastrophic fault currents. Specifications Lockable switch in the off position with primary integral CLASS CC fuses Secondary fuseholders only - suitable for 13/32 x 1 1/2 fuses Voltage regulation Surge and noise suppression 15 Amp GFCI receptacle Four flexible mounting configurations Input: Output: 408-552 Volts, 480 Volts nominal, single phase 60 Hz Regulated 120V ±3% for an input range of 480V ±15% Unregulated 120V Auxiliary CVFB Separate Auxiliary kva Regulated Auxiliary kva Amps Maximum Secondary Current Auxiliary Regulated Approx. Wt. CVFB*-0707 0.5 0.5 6 6 6 120 (54) CVFB*-0507 1.0 0.5 10 12 6 132 (60) CVFB*-0705 0.5 1.0 10 6 12 132 (60) CVFB*-0505 1.0 1.0 12 12 12 165 (75) CVFB*-0701 0.5 2.0 15 6 25 176 (80) CVFB*-0501 1.0 2.0 20 12 25 177 (80) CVFB*-0515 1.0 3.0 25 12 30 197 (89) CVFB*-0301 1.5 2.0 20 20 25 200 (91) CVFB*-0101 2.0 2.0 25 25 25 210 (95) CVFB*-1501 3.0 2.0 30 30 25 215 (98) *Select mounting configuration letter when ordering. A - Top Mount B - Side Mount C - Front Mount D - Modular Mount Note: D - shipped in two separate enclosures, requires customer to interconnect. Dashed area indicates transformer and capacitor section. 3

Mounting Configurations 4

Disconnect - NEMA 1 / IP22 DTFB Series Dual (1 kva - 4 kva) The Daykin DTFB Series provides two independent transformers to supply separate outputs for machine tool and auxiliary functions. Both transformers are electrostatically shielded to provide enhanced protection against noise and transients. Lockable switch in the off position with primary integral CLASS CC fuses Electrostatically shielded transformers Two independent outputs Wide range of transformer ratings T1 kva T2 kva F5 & F6 F7 F8 & F9 0.5 0.5 DTFB-0707 6 2 2 6 6 53 (24) 1.0 0.5 DTFB-0507 10 5 2 12 6 80 (36) 1.0 1.0 DTFB-0505 12 5 5 12 12 80 (36) 1.0 2.0 DTFB-0501 15 5 10 12 25 53 (24) 1.0 3.0 DTFB-0515 25 5 15 12 30 80 (36) 5

Disconnect - NEMA 1 / IP22 LTFB Series Low Profile (0.5 kva - 2 kva) The Daykin LTFB Series is based on the original Daykin transformer disconnect and features a low profile design. The enclosure is less than 8 (203.2 mm) in depth. This series is available from 0.50 kva through 2 kva. All transformers are electrostatically shielded. This series is utilized for a wide variety of applications including interior panel lighting. Lockable switch in the off position with primary integral CLASS CC fuses Electrostatically shielded transformers An overall depth of 7.88 for use within relatively shallow control panel enclosures 0.5 LTFB-0.5 3 6 29 (13) 1.0 LTFB-1 6 12 35 (16) 1.5 LTFB-1.5 12 20 42 (18) 2.0 LTFB-2 12 25 51 (23) 6

Disconnect - NEMA 1 / IP22 LTFS Series Low Profile (0.5 kva - 3 kva) The Daykin LTFS Series is based on the original Daykin transformer disconnect and features a low profile design. The enclosure is less than 8 (203.2 mm) in depth. This series is available from 0.50 kva through 3 kva. All transformers are electrostatically shielded. This series is utilized for a wide variety of applications including interior panel lighting. 5 ka RMS short circuit current rating Lockable switch in the off position with primary CLASS CC fuses Electrostatically shielded transformers An overall depth of 7.88 for use within relatively shallow control panel enclosures Economical version of LTFB 0.5 LTFS-0.5 3 6 29 (13) 1.0 LTFS-1 6 12 35 (16) 1.5 LTFS-1.5 12 20 42 (18) 2.0 LTFS-2 12 25 51 (23) 3.0 LTFS-3 20 30 80 (36) 7

Disconnect - NEMA 1 / IP22 GM2F1F Series Modular Disconnect (1 kva - 3 kva) The Daykin GM2F1F Series is modular in construction. This transformer disconnect is a two component system. The transformer compartment is epoxy encapsulated, enclosed and designed to mount on the outside of the control panel. The disconnect compartment accommodates the switch and all overcurrent protection. This NEMA 1 / IP22 compartment is designed to mount inside the control panel. All termination points are well identified for easy interconnection. This system is well suited for applications where backplate space is at a premium. It also avoids additional heat load loss within the control panel. 200 ka RMS short circuit rating Lockable switch in the off position with primary integral CLASS CC fuses Electrostatically shielded transformers 1.0 GM2F1F-1 6 12 39 (18) 1.5 GM2F1F-1.5 12 20 59 (27) 2.0 GM2F1F-2 12 25 78 (35) 3.0 GM2F1F-3 15 30 91 (41) 8

Disconnect - NEMA 1 / IP22 GMDGT Series Compact Disconnect (0.5 kva - 1 kva) The GMDGT Series is suitable for use on circuits capable of delivering up to 200,000 A RMS symmetrical short circuit current to meet the most stringent Canadian and UL 508A requirements. This NEMA 1 / IP22 enclosed series features a small footprint for applications where backplate space is at a premium. Lockable switch in the off position with primary integral CLASS CC fuses Electrostatically shielded transformers 0.5 GMDGT-0.5 3 6 31 (14) 1.0 GMDGT-1 6 12 39 (18) 9

Disconnect - NEMA 1 / IP22 GOMDGT Series Compact Disconnect (1.5 kva - 3 kva) The GOMDGT Series is suitable for use on circuits capable of delivering up to 200,000 A RMS symmetrical short circuit current to meet the most stringent Canadian and UL 508A requirements. This series offers a NEMA 1 / IP22 enclosed disconnect with a choice of three large open transformers, while maintaining the smallest possible footprint. Lockable switch in the off position with primary integral CLASS CC fuses Electrostatically shielded transformers Open style transformer for maximum thermal dissipation Variable mounting dimensions 1.5 GOMDGT-1.5 12 20 2.0 GOMDGT-2 12 25 3.0 GOMDGT-3 15 30 Dimensions are in inches and (mm) A B C D 11.77 6.38 4.50.69 (299) (162) (114) (17.5) 11.77 6.38 4.50.69 (299) (162) (114) (17.5) 12.71 (323) 7.50 (191) 5.50 (140).90 (22.9) 38 (17) 39 (18) 55 (25) 10

Disconnect - NEMA 1 / IP22 MDGT Series Compact Disconnect (0.5 kva - 1 kva) The Daykin MDGT Series is a NEMA 1 enclosed transformer disconnect with a small footprint for use where backplate space is at a premium. 5 ka RMS short circuit current rating Lockable switch in the off position with primary CLASS CC fuses Electrostatically shielded transformer provides positive protection against short circuits from the primary to the secondary, as well as attenuating high frequency noise and transients Economical version of GMDGT family 0.5 MDGT-0.5 3 6 24 (11) 1.0 MDGT-1 6 12 29 (13) 11

Disconnect - NEMA 1 / IP22 OMDGT Series Compact Disconnect (1.5 kva - 3 kva) The Daykin OMDGT Series offers a NEMA 1 enclosed disconnect with a choice of three large open transformers. This series provides greater power while still maintaining the smallest possible footprint. 5 ka RMS Short Circuit current rating Lockable switch in the off position with primary CLASS CC fuses Electrostatically shielded transformer provides positive protection against short circuits from the primary to the secondary, as well as attenuating high frequency noise and transients Open style transformer for maximum thermal dissipation Economical version of GOMDGT family 1.5 OMDGT-1.5 12 20 2.0 OMDGT-2 12 25 3.0 OMDGT-3 15 30 Dimensions are in inches and (mm) A B C D 11.77 6.38 4.50.69 (299) (162) (114) (17.5) 11.77 6.38 4.50.69 (299) (162) (114) (17.5) 12.71 (323) 7.50 (191) 5.50 (140).90 (22.9) 38 (17) 39 (18) 55 (25) 12

Disconnect - NEMA 12 / IP54 GPFB Series General Purpose ( 0.50 kva - 3 kva) The Daykin GPFB Series is a NEMA 12 / IP54 enclosed transformer disconnect suitable for mounting on the outside of an electrical control panel. This enclosure has provisions for base or side mounting. Dual mounting capability offers flexibility. Lockable switch in the off position with primary integral CLASS CC fuses Electrostatically shielded transformer provides positive protection against short circuits from the primary to the secondary, as well as attenuating high frequency noise and transients Continuous hinged door with neoprene gasketing and enclosure seams continuously welded Optional covered GFCI protected receptacles 0.5 GPFB-0.5 3 6 39 (18) 1.0 GPFB-1 6 12 44 (20) 1.5 GPFB-1.5 12 20 56 (25) 2.0 GPFB-2 12 25 60 (27) 3.0 GPFB-3 15 30 66 (30) 13

Disconnect - NEMA 12 / IP54 GPFS Series General Purpose ( 0.50 kva - 3 kva) The Daykin GPFS Series is a NEMA 12 / IP54 enclosed transformer disconnect suitable for mounting on the outside of an electrical control panel. This enclosure has provisions for base or side mounting. Dual mounting capability offers flexibility. 5 ka RMS short circuit current rating Lockable switch in the off position with primary CLASS CC fuses Electrostatically shielded transformer provides positive protection against short circuits from the primary to the secondary, as well as attenuating high frequency noise and transients Continuous hinged door with neoprene gasketing and enclosure seams continuously welded Two optional 15 Amp receptacles 0.5 GPFS-0.5 3 6 39 (18) 1.0 GPFS-1 6 12 44 (20) 1.5 GPFS-1.5 12 20 56 (25) 2.0 GPFS-2 12 25 60 (27) 3.0 GPFS-3 15 30 66 (30) 14

Disconnect - NEMA 12 / IP54 GNTB Series General Purpose ( 5 kva - 7.5 kva ) The Daykin GNTB Series is a NEMA 12 / IP54 enclosed transformer disconnect with a large capacity machine tool transformer. Dual mounting capability offers flexibility. Lockable switch in the off position with primary integral CLASS CC fuses Secondary fuseholders only - suitable for CLASS RK5 fuses Electrostatically shielded transformer provides positive protection against short circuits from the primary to the secondary, as well as attenuating high frequency noise and transients Flange mounted lockable disconnect switch with visible blade construction Continuous hinged door with neoprene gasketing and enclosure seams continuously welded Two optional 15 Amp receptacles 5.0 GNTB-5 20 60 125 (57) 7.5 GNTB-7.5 25 60 155 (70) 15

Disconnect - NEMA 12 / IP54 STDAB1 Series General Purpose Flange Mounted Switch (1 kva - 3 kva) The Daykin STDAB1 Series is a NEMA 12 / IP54 enclosed transformer disconnect with a flange mounted disconnect switch. This enclosure has provisions for base or side mounting. This rugged series is well suited for the industrial plant environment. Lockable switch in the off position with primary integral CLASS J fuses Secondary fuseholders only - suitable for CLASS J fuses Electrostatically shielded transformer provides positive protection against short circuits from the primary to the secondary, as well as attenuating high frequency noise and transients Flange mounted lockable disconnect switch with visible blade construction Continuous hinged door with neoprene gasketing and enclosure seams continuously welded Optional 15 Amp GFCI receptacle with cover 1.0 STDAB1-1 6 12 57 (26) 1.5 STDAB1-1.5 12 20 68 (31) 2.0 STDAB1-2 12 25 72 (33) 3.0 STDAB1-3 15 30 81 (37) 16

Disconnect - NEMA 12 / IP54 GSTDAB1 Series General Purpose Flange Mounted Switch (5 kva - 7.5 kva) The Daykin GSTDAB1 is suitable for enclosed transformers supplying 5-7.5 kva featuring a flange mounted disconnect switch. This rugged series is appropriate for the industrial plant environment. A larger version of the STDAB1 family but without the dual mounting brackets. Lockable switch in the off position with primary integral CLASS J fuses Secondary fuseholders only - suitable for CLASS J fuses Electrostatically shielded transformer provides positive protection against short circuits from the primary to the secondary, as well as attenuating high frequency noise and transients Flange mounted lockable disconnect switch with visible blade construction Continuous hinged door with neoprene gasketing and enclosure seams continuously welded with cover 5.0 GSTDAB1-5 25 60 150 (68) 7.5 GSTDAB1-7.5 30 80 210 (95) 17

Disconnects Options Available for Disconnects General Options Available Add Suffix (5) Standard duplex receptacle ( with fuseholder only ) D (3) (4) Secondary fuses provided GFCI receptacle provided (with fuseholder only) G (4) F GFCI breaker to protect entire load B (1) European Shuko style receptacle 2P, 3W, 250V ( w ith fuseholder only) Universal receptacle provided (with fuseholder only) M R No pilot light (pilot light is provided by default) N CE Certified CE Additional secondary fuseholder ( not available with receptacle, contact sales office ) A (5) 3 primary fuses provided (2 provided by default) P Voltage Options Volts Secondary Volts Hertz Add Suffix 240 120 60 240 380 115 50 380 400 115 50 400 415 115 50 415 600 120 60 600 380 220 50 3802 (2) 400 220 50 4002 (2) 415 220 50 4152 (2) 480 240 60 4802 (2) 480/380 120 50/60 431 480/380 220 50/60 432 (2) Footnotes (1) For outputs greater than 20A, option A secondary fuseholder (supplied without fuse) must be added. (2) Options D and G are not available with these voltage combinations: must use options M or R if receptacle is required. (3) Cannot use standard receptacle on NEMA 12 enclosed units, due to potential outside installation; must use GFCI receptacle. (4) Options D and G may not be able to be installed in all units together. (5) More than 3 options, and certain combinations ( A with 600VAC), will require a special part number. Please contact Customer Service to obtain part number for ordering purposes. 18