There are three possible installation kits for the MIS5022 switch. Make sure that you have the installation kit that you ordered.

Similar documents
Rack Installation Instructions

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Rack installation instructions

AU-110 racking guide NBXPN: 023

Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, REV A.6 DECEMBER 9,

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Raritan LCD KVM Console (T1700/T1900)

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Rack Installation Instructions

Raritan LCD KVM Console (T1700/T1900)

AM/FM ANTENNA RELOCATION KIT

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

INSTRUCTIONS: LocknCharge Laptop Carts

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Dell E Series Monitor VESA Mounting Bracket Installation Instructions

Installation. Basic Rack Power Distribution Unit for Blade Servers

RM410. Hardware Installation Guide. Quick Start Guide. Rack Mounting Kit. Version 1.00 Edition 1, 12/2012

Part Name/Description Part Number Quantity. Power Cable

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Server Chassis and Triplet Hardware v1.0

HP 16/18-Port Cable Management Kit Installation Guide

HP UPS R1500 Generation 3

Cabinets 101: Configuring A Network Or Server Cabinet

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

42U/45U 28" Wide Rack Installation & Service Guide

16/32 Channel 1U Rack Mount CCTV Power Supply

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

The power module is Feature Number 8800-F2-901.

ELECTRONICS G H I J K L M

About the HotWire Slot Standalone Shelf

About the BitStorm 6051 POTS Splitter

PS6500 Storage Arrays Rack Mount Instructions

CETAC Z-Drive Assembly

Quick Setup Guide. Tandberg Data DPS1000 Series Model: DPS1100 and DPS1200, Release: 1.3

Anthro Tablet Charging Cabinets

430 Power/Electronics Replacement

How To Install A Cisco Cisco 520-T1 Router On A Network Card (Cisco) With A Network Cable (Cio) And A Network (Cnet) (Coconc) (Net) And An Ipo (

UPGRADING AND SERVICING GUIDE

Front Panel Board Cable Replacement Instructions

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

Replacing the Gateway M675 Keyboard

Processor Cage Fans, Front and Rear Replacement Instructions

Quick Start Guide Series 1 RU Gen 2 Data Center Switches. Arista Networks. DCS-7150S-64 PDOC

PDI-P10LCD Pre-Tensioned Swivel Cartridge

INSTALLATION INSTRUCTIONS

Co-location Interconnect Power Panel (CIPP) Installation Guide

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

BUGGY SETUP GUIDE. Volume GOKARTSUSA GY6 150, CN250. Buggy Setup Guide

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

RAIN COLLECTOR S HELF MANUAL

Set Up Your MXI -Express x1 System

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

UNPACKING AND ASSEMBLY

MCR1900 Media Converter 19-Slot Chassis

Base Cabinet Assembly Instructions

Set Up Your MXI -Express x4 System

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

Access Server Rack Cabinet Compatibility Guide

Range Road RR Series Semi-Automatic Firewood Processor. Crated Unit Assembly Manual

Unpacking, Installation, and Customization

Installing Your 960 or 980 Server into a Rackmount Cabinet

All-Season Sunroom Sliding Glass Door Installation Instructions

MGB Chrome Bumper Conversion

SB-C-CTS/10TW3 SKU# & Up Cadillac CTS/CTS-V

INSTALLATION INSTRUCTIONS FOR VW MK5

Service Guide. Gateway M275

12U Adjustable 4 Post Open Frame Server Rack

Toroidal Conductivity Sensor

Installation Instructions

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

ASKING FOR ASSISTANCE

SPRITE and BIGFOOT DESKTOP CNC MACHINE KIT ASSEMBLY INSTRUCTIONS

Cable Routing Procedures for Dell PowerEdge R310 & R410 Systems

Service Manual Supplement

Amplifier: AMP Feature Summary

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

Mazda CX up B

Liebert DCR Part of the SmartRow Offering. Installation Manual 3-6, Single/Redundant and 5-10 Racks Higher Capacity Cooling Units, 60Hz

COMMERCIAL GAS DRYER

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

Post Mount Light Installation*

Uninterruptible Power Supply. 500 kva kva

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

ACL 395 Resistivity Meter

LIFT-505. BMF Lift Kit. Yamaha Drive Gas or Electric. Installation Instructions

CINEMA SB100 powered soundbar speaker

Acano solution. Acano Solution Installation Guide. Acano. January B

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Page 2 of 6. Fittings Checklist. Care & Maintenance. Additional Tools Required. General Hints & Tips When

XL PREMIUM OIL COOLER KIT

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

Transcription:

Installation Guide Installing the Switch in the Rack There are three possible installation kits for the MIS5022 switch. Make sure that you have the installation kit that you ordered. Table 1 - Installation Kit Options OPN Description For Rack Depths MIS000811 Centered single switch installation kit 400mm 800mm MIS000830 Side by side installation kit with long rail slides 650mm 800mm MIS000831 Side by side installation kit with short rail slides 400mm 650mm Package Contents The package includes: 1 switch 1 box containing 1 power cord Type B 6ft US 125V 10A chord 1 installation guide Before you install your new switch, unpack the system and check to make sure that all the parts have been sent. Check the parts for visible damages that may have occurred during shipping. If anything is damaged or missing, contact your customer representative immediately. The rack mounting holes conform to the IEA-310 standard for 19-inch racks. Guarantee proper ventilation, by leaving 8cm (3 ) of space to the front and rear of the switch. This will ensure proper air flow through the chassis. This is crucial for maintaining good airflow at ambient temperature. In particular, route cables such that they do not impede the air into or out of the chassis. Tools and Parts Tools required and customer supplied parts Phillips Screwdrivers #1 and #2 Grounding screw Mellanox Technologies Inc. 350 Oakmead Parkway, Sunnyvale, CA 94085 Tel: 408-970-3400 Fax: 408-970-3403 www.mellanox.com Document Number: 3315 Rev 1.0

ESD Strap ESD mat Grounding wire sufficient to reach a valid ground Table Top Installation 1. Peel and stick the four rubber bumpers onto the bottom of the switch. Place them in the round circles. Bottom of the switch Figure 1: Placing the Bumpers 2. Place on a flat surface. Make sure the switch is sits solid on the surface. Some national and/or local codes may require IT components to be bonded and externally grounded (not including the power cord ground). You must follow all national and local codes when installing this equipment. 3. Connect the power cord. 4. Connect the data transfer cables. Single Switch Center-of-Rack Installation 5. Installation kit parts for a single centered installation: 2 front mounting brackets 4 M6 bolts 8 flat head screws 4 caged nuts for the rack vertical supports 2 Mellanox Technologies

Installation Kit for a Single Centered Installation Figure 2: Connect the Mounting Brackets The following procedure can be done by one person. 1. Place the ESD mat on the floor where you will be working and put on the ESD strap. Make sure the ESD strap is touching your skin and that the other end is connected to a verified ground. 2. Screw the two front brackets to the front side of the switch using 4 flat head screws for each bracket. 3. Place four caged nuts into the rack at the U level you want to install the switch. 4. While supporting the switch catch and tighten the four bolts into the caged nuts. 5. Ground the switch. For more information see Section, Grounding the switch, on page 6. 6. Plug in the power cord. 7. You can start connecting all of the cables to the switch. Mellanox Technologies 3

Side by Side Installation Installation kit parts for a side by side installation: 1 Two switch metal frame 4 switch mounted rails 24 flat head screws Two Rail Slides 8 pairs of caged nuts and bolts 1 blank cover The Installation kits come with enough switch mounted rails and flat head screws to install two switches. Figure 3: Installation Kit Parts for a Side by Side Installation 1. Place the ESD mat on the floor where you will be working and put on the ESD strap. Make sure the ESD strap is touching your skin and that the other end is connected to a verified ground. 2. Screw the two switch mounted rails to the switch using six flat head screws per rail. 4 Mellanox Technologies

Figure 4: Screw on the Switch Mounted Rails 3. Place eight caged nuts into the rack at the level you want to mount the switch. Four go on the front side and four go on the rear side. Figure 5: Caged Nut Placement Front side Rear side 4. Install the two switch frame into the rack. This frame goes on the front side of the rack. 5. Slide the rail slides into the frame and screw the bolts into the rack caged nuts on the rear side of the rack. 6. Tighten all eight bolts to 9.2 Nm or 81.5 pound inches. 7. Slide the switch into the frame, and screw in the capture bolts into the frame. 8. Install the blank into the frame opposite the switch, or install a second switch. 9. Ground the switch. For more information see Section, Grounding the switch, on page 6. 10. Plug in the power cord. 11. You can start connecting all of the cables to the switch. Mellanox Technologies 5

Grounding the switch Check to determine if your local or national electrical codes require an external ground to all IT components. If so, connect a ground wire to one of the casing screws and connect the other end to a valid ground. If you choose to not use the ground screw, make sure that the rack is properly grounded and that there is a valid ground connection between the chassis of the switch and the rack. Test the ground using an Ohm meter. Some national and/or local codes may require IT components to be bonded and externally grounded (not including the power cord ground). You must follow all national and local codes when installing this equipment. 6 Mellanox Technologies