SOLAR PANEL INSTALLATION MANUAL FOR CRYSTALLINE SILICON SOLAR PHOTOVOLTAIC MODULES

Similar documents
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

GENERAL INSTALLATION MANUAL FOR EGING PV MODULES

Installation Guide of Sunrise Solartech PV Modules. Term Contents. Purpose of this guide. General. Safety precaution for installing a solar

INSTALLATION MANUAL FOR KYOCERA PV MODULES

Prism Solar Installation Manual

SHARP SOLAR Frequently Asked Questions for PV Integrators Revised 05/04/2010

YINGLI SOLAR PV MODULES Installation and User Manual

7 Watt Solar Charger Solar Panel

PM200M00 PM245P00 PM250M01 PM300P00 PM318B00 PM318B01 PM096B00 PM096B01. Version 1.2

INSTALLATION MANUAL FOR PV MODULES ENGLISH VERSION 01 - SEPTEMBER

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

INSTALLATION AND USER MANUAL FOR SHARP PHOTOVOLTAIC MODULES A) GENERAL MANUAL

Installation and Maintenance Manual

YINGLI SOLAR PV MODULES Installation and User Manual

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

CSUN Crystalline Silicon PV Module Products Installation Manual (IEC Version)

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

TruPower-Portable-500W. Solar Starter kit

Global Water Instrumentation, Inc.

Safety and Installation Instructions for AC Modules

RAY-MAX Integrated Solar Power Strip

15GAL STEEL OIL DRAIN WITH 110V PUMP

Solar Power System Installation Manual

Application Note: String sizing Conext CL Series

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Packaged Terminal Air Conditioner Wall Sleeve Installation

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

A99B Series Temperature Sensors

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Your Sharp system will be supplied with one of the following sets of panels:

12 Volt 30 Amp Digital Solar Charge Controller

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

INFRARED QUARTZ WALL HEATER

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

How To Plan Out An Array Of Solar Panels

INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER

ADDENDUM #1(BID PACKAGE # 3)

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

RayClic Connection System Installation Instructions

Design qualification and type approval of PV modules

Model 1756 Test Lead Kit

MCR1900 Media Converter 19-Slot Chassis

Mounting Tripod Kit Installation Manual

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

LED MOTION ACTIVATED FLOOD LIGHT

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

AA Solar and Sun Power Plus

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Section III Schedule of Requirements TECHNICAL SPECIFICATIONS OF THE REQUIRED SYSTEMS

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Doe Residence kw DC Roof Mounted Photovoltaic System

BB800 Off-Grid Solar System

ANTENERGY. Powered By BOSCH Cells Portable Solar Panel Kit. User Manual and Product Specifications

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Solar Electric Power System Owner s Manual

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Andersen Electric Window Opener for Andersen Awning and Roof Windows

RayClic Connection System Installation Instructions

RAIL FREE SOLAR ROOF MOUNT

ST Series POWER SUPPLIES USER INSTRUCTIONS

Peltier Application Note

AMERBRITE UNDERWATER WHITE LED POOL LAMP

PV module safety qualification according to IEC 61730:2004 EN 61730:2007

Build Your Own Solar Car Teach build learn renewable Energy! Page 1 of 1

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

SunCharger Portable Solar Panel

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

CITY OF LOS ANGELES CALIFORNIA

ERGL OWNER S MANUAL Elevated Runway Guard Light (ERGL)

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

HP UPS R1500 Generation 3

PHOTOVOLTAIC ARRAY WIRING HANDBOOK FOR STANDARD NOMINAL 6, 12, 24, AND 48 VOLT SYSTEMS. (for SX-60 series or smaller and MSX-120 solar modules)

Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit

Ducoterra Radiant Heating Panel Installation Manual

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Conext Grid Tie Solar Inverter Conext TX 2800 NA Conext TX 3300 NA Conext TX 3800 NA Conext TX 5000 NA


Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

AMPSEAL* Automotive Plug Connector and Header Assembly

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

30W SOLAR CHARGING STATION

Requirements for Electrical Installations

Solar Energy Systems. Matt Aldeman Senior Energy Analyst Center for Renewable Energy Illinois State University

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

1000-LB. TRAILER JACK OWNER S MANUAL

Transcription:

ADVANCE: SOLAR, HYDRO, WIND POWER CO. INC. (API) 6331 n. State St. Redwood Valley, CA 95470 www.advancepower.net 707-485-0588 Email: advance@advancepower.net SOLAR PANEL INSTALLATION MANUAL FOR CRYSTALLINE SILICON SOLAR PHOTOVOLTAIC MODULES Page 1

1. INTRODUCTION Thank you for choosing API solar Photovoltaic modules. API Solar is one of the leaders in the world solar energy sector and provides the highest quality crystalline silicon solar photovoltaic modules in a range of sizes designed to meet the requirements of the most demanding energy and power users worldwide. Please read this manual completely before installation or use modules. This manual applies to all API solar modules and contains important installation, maintenance and safety information. General Information The installation of solar modules requires a great degree of skill and should only be performed by qualified licensed professionals, including, without limitation, licensed contractors and electricians. WARNING The solar modules generate electricity when exposed to light. Array of many modules can cause lethal shock and burn hazards. Only authorized and trained person should have access to these modules. Cover the modules with an opaque material during installation to avoid shocks or burns. Do not touch live terminals with bare hands. Use insulated tools for electrical connections. Use appropriate methods to mount solar modules. Modules falling from high place will cause death, injury or damage. Solar modules have a protective glass front. Broken solar module glass is an electrical safety hazard (electric shock and fire). These modules cannot be repaired and should be replaced immediately. The solar module has a pair of male and female waterproof connectors. For a series electrical connection, connect positive (+) connector of first solar module to negative (-) connector of the following module. Do not short the positive and the negative. Do not disconnect under load. Be sure connector has no gap between the connector plugs. A gap between the connector plugs could cause, a fire and/or an electrical shock. Artificially concentrated sunlight must not be directed on the solar module. The electrical characteristics are indicated value of Pmax under standard test conditions (Irradiance of 1000W/m2, AM 1.5 spectrum, and cell temperature of 25 C). Under normal conditions, a solar photovoltaic module is likely to experience conditions that produce more current and/or voltage than reported at standard test conditions. Accordingly the value of Isc and Voc marked on this module should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor current ratings, fuse sizes, and sizes of controls connected to the solar output. Refer to Section 690-8 of the National Electrical Code for an additional multiplying factor of 1.25 which may also be applicable. Installation in Canada shall be in accordance with CSA C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1. 2.INSTALLATION Permit Before installing your system, contact local authorities to determine the necessary permit, installation and inspection requirements. Site Selection In most applications, API solar modules should be installed in a location where they will receive maximum sunlight throughout the year. In the Northern Hemisphere, the module should typically face Page 2

south, and in the Southern Hemisphere, the modules should typically face north. Modules facing 30 degrees away from true South (or North) will lose approximately 10 to 15 per cent of their power output. If the module faces 60 degrees away from true South (or North), the power loss will be 20 to 30 per cent. When choosing a site, avoid trees, buildings or obstructions, which could cast shadows on the solar photovoltaic modules especially during the winter months when the arc of the sun is lowest over the horizon. Shading causes loss of output, even though the factory fitted bypass diodes of the solar module will minimize any such loss. Do not install the solar module near flame or flammable materials. Do not install the solar module in a location where it would be immersed in water or continually exposed to water from a sprinkler or fountain etc. Handling and Use There are typically two or more modules in a shipping container. These containers are heavy. To safely transport these containers multiple people and/or equipment should be used to avoid injury. Protective gloves should be worn when handling solar modules. The gloves will help protect installers against sharp objects and burns. Always transport and store the modules in the shipping containers provided. Do not leave the module unsupported prior to installation. Avoid application of excessive bending or twisting forces to the module. Avoid stepping on the module or subjecting it to impact. Mounting --Climate condition Install the API Solar Crystalline series modules in the following conditions: Ambient temperature: -20 C to +40 C. Operating temperature: -40 C to +85 C. Storage temperature: -40 C to +40 C, Humidity: below 85RH% Wind pressure: below 50.12lb / ft2 (2400Pa). Corrosion resistance: Except for corrosive salt area and sulfurous area. --Module tilt angle API solar modules connected in series should be installed at the same orientation and angle. Different orientation or angles may cause loss of output power due to difference of amount of sunlight exposed to the module. API solar modules produce their full power when oriented towards the sun directly. For off grid installations, the solar modules should be tilted for optimum winter performance. As a rule, if the system power production is adequate in winter, it will be satisfactory during the rest of the year. The module tilt angle is measured between the solar modules and the ground (Figure1). Optimal tilting of solar module is almost the same as the latitude of installation location. For grid tied systems the optimum angle is usually between 20 & 30 degrees and optimizes summer power production, not winter. SUNLIGHT MODULE TILT ANGLE HORIZONTAL Figure 1 Solar Module Tilt Angle Page 3

--Mounting Systems should be installed by qualified personnel only. It involves electricity, and can be dangerous if the personnel are not familiar with the appropriate safety procedures. The module frame is made of anodized aluminum, and therefore corrosion can occur if the module is subject to a salt water environment with contact to a rack of another type of metal (Electrolysis Corrosion). If required, PVC or stainless steel washers can be placed between the solar module frame and support structure to prevent this type of corrosion. Module support structures that are to be used to support solar modules at correct tilt angles should be wind and snow load rated for use by the appropriate local and civil codes prior to installation. API solar modules should be mounted as follows: --Using stainless steel screws (M8) on the existing installing holes in the module frame. Modules must be securely attached to the mounting structure using four mounting points for normal installation. If additional wind or snow loads are anticipated for this installation. Refer to the drawing, below. Load calculations are left to the system designer or installer. The frame of each module has 4 mounting holes (12mm*9mm) used to secure the modules supporting structure. The module frame must be attached to a supporting structure using M8 stainless steel hardware together with bolt, spring washers, flat washers and nut in four places symmetrical on the solar module. The applied torque is 8 Newton-meters. Page 4

The modules have been evaluated by UL for a maximum positive or negative design loading of 30 lbs/ft2 using the 4 provided mounting holes in the frame. It is not permitted to modify the module frame under any circumstances. Recommended distance between 2 solar modules is 5mm considering linear thermal expansion of the module frames. Clearance between the module frame and mounting surface may be required to prevent the junction box from touching the surface, and to circulate cooling air around the back of the module. The modules are not designed for integral mounting as part of a roof or wall. The mounting design may have an impact on the fire resistance. If the modules are to be installed on the roof or wall of a building, the fire resistance of roof covering or wall should be rated for the application. Here the standoff method or the rack method is recommended. The modules are supported parallel to surface of the building wall or roof. Clearance between the module frames and surface of the wall or roof is required to prevent wiring damage and to allow air to circulate behind the module. The recommended stand-off height is 115mm. If other mounting means are employed this may affect the UL Listing. Do not mount solar module in such way that the drain holes of solar module frame get block up. Do not step on the module, although solar modules are quite rugged, the glass can be broken (and the module will no longer work properly) if it is dropped or hit by tools or other objects. Grounding All module frames and mounting racks must be properly grounded in accordance with the National Electrical Code. Proper grounding is achieved by connecting the module frame(s) and structural members contiguously one to another using a suitable bare wire and grounding clip. The wire may be bare 12 AWG copper bonding wire. The grounding clip assembly consists of a slider base, and a self captivating thread cutting screw or 8 32 screw and hex nut. The screw is used to mount the grounding clip to the frame (of the solar panel). The slider is used to hold the wire. The slider features a multi dimensional curved wire slot that provides enhanced wire retention. The base is used to terminate the wire. The base features pointed lances that provide four points of contact to the frame for high reliability and anti rotation of the grounding clip. The removal slot accepts the tip of a flat head screwdriver which is used to disengage the slider. When the slider is disengaged, the wire can be removed, and the screw is exposed for removal (Figure 2). Wire Slot Grounding Wire Grounding Wire Slider Slider Slider Frame Screw Frame Screw Frame Screw Installation 1: Place the grounging clip onto the frame. Then tighten the screw. Installation 2: Insert the wire into the wire slot. Installation 3: Manually push the slider over the base until it covers the base. This will terminate the wire. Figure 2 Grounding Clip Installations API solar modules and mounting assemblies can also be grounded utilizing UL listed Weeb grounding systems and plates as long as manufacturers installation guidelines are followed. Grounding methods shall comply with NEC Art. 250. Page 5

Each module has two #12 AWG type standard 90 C sunlight resistant output cables each terminated with positive & negative connectors. This cable is suitable for applications where wiring is exposed to direct sun. Refer to NEC for wiring details in accordance with the National Electrical Code (NEC). For field connections, use a minimum No. #12 AWG copper wires insulated for a minimum of 90 C and Sunlight resistant. The Bypass diodes and blocking diodes Partial shading of an individual module can cause a reverse voltage across the shaded solar module. Current is then forced through the shaded area by the other modules. When a bypass diode is wired in parallel with the series string, the forced current will flow through the diode and bypass the shaded solar module, thereby minimizing module heating and array current losses. In system utilizing a battery, blocking diodes are typically placed between the battery and the solar module output to prevent battery discharge at night (charge controller). Diodes that are used as blocking diodes must: Have a Rated Average Forward Current [IF(AV)] above maximum system current at highest module operating temperature. Have a Rated Repetitive Peak Reverse Voltage [VRRM] above maximum system voltage at lowest module operating temperature. 3. MAINTENANCE Under most weather conditions, normal rainfall is sufficient to keep the solar module glass surface clean. If dirt build-up becomes excessive, clean the glass only with a soft cloth using mild detergent and water. Use caution when cleaning the back surface of the module to avoid penetrating the substrate materials. Solar Modules that are mounted flat (0 tilt angle) should be cleaned more often, as they will not ''self clean'' as effectively as modules mounted at a 15 tilt or greater. Once a year, check the tightness of terminal screws and the general condition of the wiring. Also, check to be sure that mounting hardware is tight. Loose connections will result in damage for array. Changed solar module must be the same kind and type. Do not touch live parts of cables and connectors. Use appropriate safety equipment (insulated tools, insulating gloves, etc.), when touching them. Cover the front surface of the solar module by an opaque or other material when repairing. The solar modules when exposed to sunlight generate high voltage and are dangerous. For further information, please visit our website www.advancepower.net or contact your API Authorized Representative. 4. SPECIFICATIONS Notes 1. Standard Test Condition (STC): 1000 W/m², 25 C cell temperature and solar spectral irradiance per ASTM E 892, IEC 60904-3, irradiation of AM 1.5 spectrum. 2. Nominal Operating Cell Temperature (NOCT): 47±2 3. Rated electrical characteristics are within 10 percent of measured values at Standard Test Conditions. 4. Temperature coefficient of Current is 0.05%/ºK, Temperature coefficient of Voltage is - 0.35%/ K. 5. See solar module drawings for mounting and grounding holes locations (Figure 3). Page 6

60pcs 156 156mm Multicrystalline Silicon Solar Module 1650 992 46 19.50 72pcs 125 125mm Monocrystalline Silicon Solar Module 1581 809 40 15.60 UL1703: 600VDC & IEC61215/IEC61730:1000VDC 15 10 Dimensions (mm) Weight (kg) Module Series Model Power P m(w) Electrical Performance at STC Power Voltage V (V) Power Current I (A) Open- Circuit Voltage V (V) Short- Circuit Current I (A) mp mp OC SC System Voltage (VDC) Series Fuse (A) API-150 150 34.40 4.40 42.6 4.19 API-160 160 34.90 4.60 42.8 5.15 API-165 165 35.60 4.65 43.2 5.20 API-170 170 35.80 4.75 43.6 5.25 API-175 175 36.20 4.85 43.9 5.30 API-180 180 36.80 4.90 44.2 5.35 API-156P-200 200 28.7 6.97 36.0 7.75 API-156P-210 210 29.2 7.19 36.4 7.86 API-156P-220 220 29.8 7.39 36.8 8.00 API-156P-230 230 30.0 7.66 37.0 8.18 Connector Figure 3 Backside of SOLAR Module Page 7