MTU Onsite Energy unveils new Series 1600 diesel generator sets

Similar documents
Energy-efficient data center achieves 2N reliability; MTU Onsite Energy generator sets provide critical backup

LEED-certified COPT DC-6 Data Center s green design includes innovative backup power solutions from MTU Onsite Energy

POWER GENERATION.

Bergen Engines Products and Applications

Anwendung von Polyspace im Software Entwicklungsprozess nach IEC München, , Dr.-Ing. Jörg Barrho

Chad Dozier Market Development Manager Electric Power Division. August 2013

Understanding Tier 4 Interim and Tier 4 Final EPA regulations for generator set applications

MTU ONSITE ENERGY. Madrid, November 19 th, MTU Onsite Energy GmbH All rights reserved

Integrated Power Systems for Data Centers

A reliable and experienced supplier

Development of Power Supply System with Hybrid Turbocharger for Marine Application

Brochure. Electric generators to power the world

Power backup in data centers. Something going on. 24 I MTU Report 03/10

FPT FIAT POWERTRAIN TECHNOLOGIES PRESENTS ITS ENGINE RANGE FOR CONSTRUCTION APPLICATIONS AT INTERMAT 2009

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

Redesign of kW Diesel Products Reflects Voice-of-The-Customer Improvements

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Reliable Power for an Unreliable World Light Commercial Standby Generators

The State Fire Marshal's Office and the VDH/Office of Licensure and Certification. Generator Testing in Nursing Facilities

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

Minimizing Impact of Electric Utility Outages with Backup Generation

Process Alarm Solutions

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

SPP Pumps Inc. Atlanta

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

J. Freihaut, Ph.D. Architectural Engineering, Professor Penn State Univesity

Paralleling Switchgear

Frequently Asked Questions Generators

VM 32. Efficiency and Performance New Product Development Modular Design Cylinder

MORE PRODUCTS. MORE RELIABILITY. MORE REaSONS TO USE GENERAC. industrial generators UP TO 2MW. single sets

ABB Inc. April 19, 2011 Slide 1

THM Gas Turbines Heavy duty gas turbines for industrial applications

SSE s criteria used for GHG emissions reporting

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

MICRO HYDRO POWER GENERATING EQUIPMENT

Dual Fuel Medium Speed Product. Presenter Name Date

INSPECTION AND TESTING OF EMERGENCY GENERATORS

Data Center Combined Heat and Power Benefits and Implementation. Justin Grau, Google Inc. Sam Brewer, GEM Energy

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Power to the adaptable data center

HyPM Fuel Cell Power Modules

C18 ACERT Fire Pump Tier bkw/ rpm

CAT CG132. Series Gas Generator Sets

Paralleling Power Sources Which Share a Common Neutral

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice

DIESEL GENERATOR SETS

Powering Productivity. EveryTMEngine. QSX11.9 And QSX15 ( hp) Tier 4 Interim/Stage IIIB

Clear Advantage. EveryTMEngine. QSB6.7 And QSL9 ( hp) Tier 4 Interim/Stage IIIB

Power Island. Industrial Power Plants. / energy

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Auxiliary Power Unit (APU) for Military Vehicles

DC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility

Micro-Turbine Combined Heat & Power Generators (CHP) Cold Climate Applications 2014 Polar Technology Conference Richard S.

Diesel Engine Driven Generators Page 1 of 6

Hybrid Power Considerations for Today s Telecommunications

Fluid Automation Solutions

Floating. Diesel power stations

Generators TEM. for small hydroelectric power stations. Electric Machines

Press Presse Press Presse

ABB PSPS Erich Steinmann; Generator control-2013

MTU and Deutsche Bahn test hybrid train

Distributing Power to Blade Servers

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

ACTURA V DC, 3-40 kw, A. The Regional DC power system with Global Muscle

Totally Integrated Power SIESTORAGE. The modular energy storage system for a reliable power supply.

Diesel and gas engine systems for EURO VI on-highway applications

Training Systems for Renewable Energies. Acquiring Practical Skills and Project-oriented Expertise

Reduce the cost of communication with ComAp. Telecom tower solutions

-Liquid-cooled frequency converter switchgear

Using the Phoenix MultiPlus

Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)

1. Do you have onsite emergency power generation in any of your facilities? R=992

A Discussion of PEM Fuel Cell Systems and Distributed Generation

Transit Investments for Greenhouse Gas and Energy Reduction

RENEWABLE ENERGY. The Sustainable Energy Plant.

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Power Generation generator sets kva to 15 MW

How To Drive A Marladebronn Hybrid Bus

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

A study into the fuel savings potential by a major rebuild of propulsion system

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Bharat Petroleum: Fueling Real Estate Revenues with SAP Real Estate Management

Advanced Fuel Cells A Reliable and Green Solution to Reduce Operating Expenses of Telecommunication Networks

How To Control A Power Command Powerplant

Galaxy VM. Three-phase power protection. schneider-electric.com

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Gas turbine power plants

Who do the biggest names in servers, search, healthcare, cloud & financial services trust to provide power management solutions?

Technical Specification. Generating Set with Waukesha engine burning natural gas

TRITON V. Cylinder Pressure Monitoring CPM 500. Replaces mechanical indicators on diesel engines. Improves combustion

Fast Charging Facts Enhancing use of electric lift trucks, AGVs, and other motive electric vehicles

PROCUREMENT GUIDE: SELECTING A CONTRACTOR/PROJECT DEVELOPER

NISSENS WATER-COOLED CHARGE AIR COOLER

Engine catalogue. Marine Diesel engines. MAN range - light duty

Transcription:

October 7, 2009 Press Information Contact: Jennifer Riley Telephone: +1 313 592-8103 Email: jennifer.riley@mtu-online.com Agency contact: Robert E. Sheldon, APR Creative Communications Consultants, Inc. Phone: 210-828-1880 Email: rsheldon@cccinc.com Editor note: To download this news release, go to: www.cccinc.com/pr/mtuonsite/series1600 MTU Onsite Energy unveils new Series 1600 diesel generator sets New MTU Series 1600 generator sets extend range of MTU diesel-powered generator sets from 250 kw to 3,250 kw. Mankato, Minnesota MTU Onsite Energy, a leader in distributed power solutions, introduces its newest MTU diesel-powered generator set covering a range of 250 kw to 600 kw. The new genset is based on the MTU Series 1600 engine, through which MTU s proprietary power range is extended from as low as 250 kw up to 3,250 kw. The Series 1600 engine is a completely new engine for MTU and is the smallest engine that the company produces. It has all the hallmarks of an MTU engine: exceptional reliability, high power density and fuel efficiency. When combined with MTU Communications, 13400 Outer Drive West, Detroit, Michigan 48239 USA

2/5 the completely new design of the generator set package, the result is a compact powerhouse that is ideal for emergency standby and peak-shaving applications. The engine s load acceptance is exceptional, says Neil Majeski, program manager for the Series 1600 genset. It is an incredibly stable engine that is very well built. The Series 1600 engines, from 12V to 6-cylinder inline, will offer an advantage in covering power nodes that were previously sourced from two different engine manufacturers. The Series 1600 diesel generator set comes standard with many features that previously required custom ordering. Standard features include: EPA Tier 2 certification Compliance to ISO 8528-5 testing for transient response at 85% load (as opposed to standard testing at 70% load) NFPA 110 one-step rated load acceptance (1 step 100% block load) Digital control panels that are UL recognized In addition, the outlet box on the Series 1600 genset has been designed to incorporate not only the outlet box, but also the breaker and control panels in one streamlined package. Its design allows for the flexibility to switch the control panels and breakers to the right or left depending on the need, and allows the mainline circuit breaker to be installed in a compartment on the right or left side per customer specification. The outlet box can accommodate multiple mainline circuit breakers,

3/5 utilizing both compartments. This is a standard design feature that previously would have required custom engineering. We are very excited about the outlet box housing everything, says Majeski. The design not only offers greater flexibility, but it also gives the genset a well-packaged look with very clean lines. The Series 1600 generator sets also have an improved electrical stub-up compared to similar gensets powered by other engine types. The new design allows ample room for connecting cables in the stub-up area, thus making installation easier. Another design advantage is in the mounting of the outlet box. Whereas previous generator set designs mounted the outlet box to the barrel of the alternator, the Series 1600 outlet box is mounted directly to the base of the genset. This significantly reduces the amount of vibration to which the outlet box is subjected, which has a positive effect on the life of the electrical system. Generator sets based on the 12V configuration of the Series 1600 are currently available in 550 kw - 600 kw power nodes. MTU Onsite Energy has already received several orders for the Series 1600 generator sets, the first of which are scheduled for delivery in December.

4/5 EDITOR S NOTE: To download this news release and high-resolution photo, go to: www.cccinc.com/pr/mtuonsite/series1600 (MTU-8141) To introduce the new MTU Series 1600 gensets, this 600 kw unit was used to power a social event for nearly 300 MTU Onsite Energy customers and distributors at the company's headquarters in Mankato, Minnesota. - End - MTU Onsite Energy Corporation MTU Onsite Energy Corp. (formerly Katolight Corporation) is a leading producer of diesel-powered generator sets from 30 to 3,250 kw and natural gas-powered generator sets from 20 to 400 kw for standby, prime power and cogeneration applications. The company also provides automatic transfer switches, paralleling switchgear, controls and accessories for complete power system solutions. Based in Mankato, Minnesota, MTU Onsite Energy Corp. combines the expertise of Katolight and MTU Detroit Diesel Power Generation under one brand to meet the ever increasing distributed power needs of customers in North America and around the world. MTU Onsite Energy Corp. is part of the Tognum Group s business unit, Onsite Energy and Components. For more information, visit www.mtu-online.com Tognum With its two business units, Engines and Onsite Energy & Components, the Tognum Group is one of the world s leading suppliers of engines, propulsion systems and distributed energy systems. These products are based on diesel engines with up to 9,100 kilowatts (kw) power output, gas engines up to 2,150 kw, fuel cells up to 360 kw and gas turbines up to 50,000 kw.

5/5 The product portfolio of the Engines business unit comprises MTU engines and propulsion systems for ships, for heavy land, rail and defense vehicles, and for the oil and gas industry. The portfolio of the Onsite Energy & Components business unit includes distributed energy systems of the brand MTU Onsite Energy, fuelinjection systems from L Orange, and drive shafts from Rotorion. The energy systems comprise diesel engines for emergency power generation, basic and peak load, and cogeneration power plants based on gas engines, fuel cells and gas turbines that generate both electricity and heat. In 2008, Tognum generated revenue of more than 3.1 billion and employs more than 8,900 people. Tognum has a global distribution and service structure with 26 fully consolidated subsidiaries, more than 140 sales partners and over 500 authorized dealerships at approximately 1,200 locations. The shares of Tognum AG (ISIN: DE000A0N4P43) have been stock-exchange listed since 2007 and are included in the MDAX.