Entis Pro version 2.50x. Installation guide Entis Pro version 2.50x

Similar documents
Entis Pro for Windows 7 OPC Server

Ultra Thin Client TC-401 TC-402. Users s Guide

AXIS Camera Station Quick Installation Guide

User s Guide for version 5 Page

GE Healthcare Life Sciences UNICORN Administration and Technical Manual

@ptitude Observer. Installation Manual. Part No Revision G

ClearSCADA. Software for Telemetry & Remote SCADA Solutions

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Guest PC. for Mac OS X. User Guide. Version 1.6. Copyright Lismore Software Systems, Ltd. All rights reserved.

IntelliVue PC Printing Solution. Installation and Configuration Guide. IntelliVue PC Printing Solution. Revision F Patient Monitoring

CODESOFT Installation Scenarios

SA-9600 Surface Area Software Manual

UFR II Driver Guide. UFR II Driver Ver ENG

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

How To Set Up A Firewall Enterprise, Multi Firewall Edition And Virtual Firewall

SOFTWARE INSTALLATION INSTRUCTIONS

Fiery E100 Color Server. Welcome

64-Bit Compatibility with Micromeritics Applications

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

Topaz Installation Sheet

Installation & Upgrade Guide. Hand-Held Configuration Devices Mobility DHH820-DMS. Mobility DHH820-DMS Device Management System Software

Installing the Microsoft Network Driver Interface

Operating System Installation Guide

RSView 32 ACTIVE DISPLAY SYSTEM GETTING RESULTS GUIDE. PUBLICATION VW32AD-GR001E-EN-E July 2011 Supersedes Publication VW32AD-GR001D-EN-E

Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

Wireless LAN g USB Adapter

S-SupremaConfigurationGuide-DOC 7/23/2014. Suprema Biometrics Configuration Guide ACS OnSite Aparato

Preparing the Windows version of the software for use

ENTBUS PLUS SOFTWARE FOR ENERGY MONITORING AND RECORDING INSTALLATION AND OPERATING MANUAL

EasyMP Multi PC Projection Operation Guide

Terminal Automation Solutions

VERITAS Backup Exec TM 10.0 for Windows Servers

QIAsymphony Management Console User Manual

1. TIB388 about the Windows compatibility of all Mutoh devices subdivided in

i -CEN S USER S Manual

IX Support Tool Setting Manual

TOSHIBA GA Printing from Windows

Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.

Point of Sale 2015 Enterprise. Installation Guide

Operating Instructions

Windows Peer-to-Peer Network Configuration Guide

Iridium Extreme TM Satellite Phone. Data Services Manual

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version

X Series Application Note 43:

AVG 8.5 Anti-Virus Network Edition

The Wireless LAN (Local Area Network) USB adapter can be operated in one of the two following networking configurations :

V2.7.x Installation on a Database Server Note: This document is to be used on a new database server installation.

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

Serial ATA 2 Ports PCI Host

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Installation Guide v1.11 and Higher

Installation and Operation Manual Portable Device Manager, Windows version

RDC-7 Windows XP Installation Guide

In the same spirit, our QuickBooks 2008 Software Installation Guide has been completely revised as well.

1 Minimum system requirements

Recommended Network Setup

STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS

AccXES Client Tools 10.0 User Guide 701P41529 May 2004

CMP-102U. Quick Installation Guide

USB Flash Memory TransMemory-EX II TM

Network Setup Guide. Introduction. Setting up for use over LAN

StrikeRisk v6.0 IEC/EN Risk Management Software Getting Started

Windows 2003 Server Installation Guide

EASE Scan Tool Customers. SECTION I - Installation

Instruction manual. testo easyheat Configuration and Analysis software

FrontDesk Installation And Configuration

TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer

EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server Version 1

About This Manual. 2 About This Manual

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

3M Stats and Status Software for 3M Detection System Model 8900/9900. Administrator s Guide

Installation Instruction STATISTICA Enterprise Small Business

Installing PowerLink on Windows 7 64-bit

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

Empower AutoArchive Software

Quick Start Guide GigE Vision Single-Head Controller

2014 Schneider Electric Industries SAS. This computer program is protected by copyright and international treaties.

Maxtor OneTouch User's Guide

Creatix g Adapter CTX405 V.1/V.2 User Manual

Preface Version 1.0 (1808. rev. 2)

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

Unified Communications Installation & Configuration Guide

Getting Started. rp5800, rp5700 and rp3000 Models

Sage Estimating. (formerly Sage Timberline Estimating) Installation & Administration Guide

Diamond II v2.3 Service Pack 4 Installation Manual

Release Notes - Installing the Wireless Receiver on a PC.

Allworx OfficeSafe Operations Guide Release 6.0

32 Transferring Projects and Data

1 System requirements (minimum)

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Meridian 1 Meridian 1 Attendant PC LAN Interface Installation Guide

Windows Domain Network Configuration Guide

Handheld LPC Data Retrieval Software for Windows. Operation Manual

Information in this document, including URL and other Internet Web site references, is subject to change without notice. Unless otherwise noted, the

Virtual CD v10. Network Management Server Manual. H+H Software GmbH

Administration guide. Host software WinCCU Installation. Complete gas volume and energy data management

Install Pocket Inventory in a Windows Server 2003 R2 Standard Environment

Transcription:

Entis Pro version 2.50x Installation guide Entis Pro version 2.50x

Copyright 2009 Enraf BV All rights reserved. Reproduction in any form without the prior consent of Enraf BV is not allowed. This installation guide is for information only. The contents, descriptions and specifications are subject to change without notice. Enraf BV accepts no responsibility for any errors that may appear in this installation guide. The warranty terms and conditions applicable in the country of purchase in respect to Enraf BV products are available from your supplier. Please retain them with your proof of purchase.

Preface This installation guide has been written for the technicians involved with the installation of the inventory system Entis Pro, running under the operating system Windows XP Professional. For commissioning of Entis Pro, please refer to the related manual(s). This installation guide describes the (requirements for) installation and start-up of Entis Pro and Windows XP Professional. Safety and prevention of damage Cautions and Notes have been used throughout this installation guide to bring special matters to the immediate attention of the reader. A Caution draws attention to an action which may damage (the operation of) the equipment. A Note points out a statement deserving more emphasis than the general text. Legal aspects The information in this installation guide is copyright property of Enraf BV, Netherlands. Enraf BV disclaims any responsibility for personal injury or damage to equipment caused by: Deviation from any of the prescribed procedures; Execution of activities that are not prescribed; Additional information Please do not hesitate to contact Honeywell Enraf or its representative if you require additional information. Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 3

Table of Contents Preface................................................. 3 Introduction.............................................. 5 System.................................................. 6 Hardware; minimum..................................... 6 Hardware; recommended................................. 6 Hardware; optional...................................... 6 Software................................................ 6 Start Windows XP Professional.............................. 7 Windows XP Professional system settings..................... 8 Make Local Entis Pro Group and User(s)...................... 9 Set Security Policy on Change the System Time............... 12 Installation of Entis Pro.................................... 13 Entis Pro configuration.................................... 18 CIU Plus Links......................................... 18 Define New Stations.................................... 19 CIU COM Ports........................................ 20 Define CIU Plus host port links............................. 20 Tank Access Profile..................................... 22 Define View........................................... 23 Select view......................................... 23 Import view........................................ 25 Installation of additional Network stations.................... 26 Reconfiguration of an Entis Pro network station............... 27 Backup................................................ 28 How to Uninstall......................................... 29 Appendix A Windows XP Professional Network installation...... 30 Appendix B Network Configuration form................... 31 Appendix C Related documents......................... 32 4 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Introduction This installation guide introduces you to installation procedure of Entis Pro as a stand alone system or a network configuration and describes a quick overview of getting started. It shows you how to do the most common tasks, provides you with tips and points you to Windows XP Professional features which must be checked before installing Entis Pro. Before starting with the Entis pro installation procedure we strongly recommend to follow the following instructions: Install Windows XP Professional, including the required service pack (for details see the readme.txt on the CD) In case of a network system, install Windows XP Professional on all network stations Configure the network, if required (hardware, software, TCP/IP protocol) Set the regional settings correct on all stations Make sure that no other Entis Pro station is running Entis Pro software Install Entis Pro on the station which is going to be used for configuration Use Ensite Pro to configure all CIU Pluses and Primes and create Ini files In case of a network system create stations and make a list of all Station-names of the Entis Pro network Create Com ports and link the CIU Pluses and Host(s) if required. Create Groups, Views and the Tank Access Profile on the configuration station Create Entis Pro users and assign privileges In case of a network system, install the other Network stations and link CIU s and Hosts if required. See appendix A for the Network Configuration Form. All CIU Primes and Pluses must have unique RTU addresses. Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 5

System Hardware; minimum Intel Pentium Core 2 Dual E7300 2.66 GHz of better. Windows (Vista) compatible graphics card 2 Gbyte DDR2 memory Disk drive 3.5 1.44 Mbyte 60 Gbyte internal harddisk DVD Recordable (24x max) Audio output capability 1x Serial RS-232-C I/O port (9 pin D-sub) 1x Parallel port for printer (25 pin D-sub) 3x PCI Expansion slots Network Interface Card, Ethernet-Fast Ethernet Supply voltage 110 and 230 Volt (50/60 Hz) Windows XP Professional SP3 (English language) Bus Mouse (USB) US keyboard, not US international (USB) 19 TFT Monitor Loudspeaker set. Hardware; recommended UPS with serial interface Hardware; optional 21" TFT monitor PCI multi I/O board; (can be supplied by Enraf) Per CIU Plus one serial port is required Serial I/O s are used for: CIU Plus, Host 45E and UPS Software Windows XP Professional (including required service pack) This is displayed in Control Panel System - General. 6 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Start Windows XP Professional Log on as administrator. Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 7

Windows XP Professional system settings Check and modify the following (recommended) settings: 1. Open the Start Menu 2. Open Control panel (Classic View) 3. Open Regional and Language Options 4. Select Customize on the Regional Options TAB 5. Set Decimal symbol 6. Set Digit grouping symbol 7. Press OK and OK 8. Open Date and Time 9. Enter the correct Date & Time and Time zone. 10. If required enable Automatically adjust clock for daylight saving changes 11. Disable Automatically synchronize with an Internet time server 12. Press OK 13. Open System 14. Select Hardware TAB 15. Click Device Manager 16. Expand ports tree and check if sufficient ports are available 17. Close Device Manager 18. Close System Properties 19. Open Display 20. Select Settings TAB 21. Select at least 1024x768 pixels, and Highest (32 bit) 22. Press Apply 23. Select Screen Saver TAB 24. Select None 25. Press Apply 26. Select Appearance TAB 27. Press Advanced 28. Select Item: 3D objects 29. Select Color 1: 30. Press Other 31. Enter value 212 for Red, Green and Blue 32. Press OK (3x) 33. Select Power Options 34. Select Power scheme Presentation 8 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Windows XP Professional system settings 35. Press OK 36. Select User Accounts 37. Select Change the way users log on or off 38. Disable Use Fast User Switching 39. Press Apply Options Make Local Entis Pro Group and User(s) 1. Open Control Panel and select Administrative Tools 2. Open Computer Management and select Local Users and Groups - Users 3. Right mouse click on Users Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 9

Windows XP Professional system settings 4. Click on New User 5. Enter Password and a user name like the example above. Select: User cannot change password and Password never expires. Then: click on Create. 6. Select Groups 7. Right mouse click on Groups. 10 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Windows XP Professional system settings 8. Click on New Group... 9. Enter Group name (i.e. L_Entis Pro) and Description (i.e. Entis Pro users) Click on Create and Close 10. Select (double click) the previous created group (i.e. L_Entis Pro) 11. Click the Add button in the Properties screen 12. Type the name of the previous created User (i.e. Operator) 13. Click on OK and OK Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 11

Windows XP Professional system settings Set Security Policy on Change the System Time 1. Select Local Security Policy in Control Panel Administrative Tools 2. Select - Local Policies - User Rights Assignment, - Change the system time 3. Double Click Change the system time. 4. Click on Add User or Group 5. Click on Object Types and enable Groups 6. Click on OK 7. Type the name of the group (i.e. L_Entis Pro) 8. Click on OK and OK. 9. Close Control Panel. When an optional OPC server is active, the Entis Pro user must be a member of the Power Users Group instead of the L_Entis Pro group. If a network system will be installed, repeat above procedures on all Entis Pro network stations. Make sure that users and passwords are identical in the work group. User name and password are case sensitive. 12 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Installation of Entis Pro Log on as Administrator. In case of a network system: 1. Make sure that no Entis Pro is running on other stations in the network. 2. First Entis Pro has to be installed on the configuration station. 3. Configure other stations, serial ports and tanks on the first installed Entis Pro station. Then the other Entis Pro stations can be installed. 1. Insert the Entis Pro CD 2. Open My Computer 3. Select the CD 4. Start Launch.exe 5. Click on Install Entis Pro. 6. Follow the instructions on screen 7. Install preferably in the...\program Files\Entis Pro (program path) and...\documents and Settings\All Users\Application Data\ENRAF\Entis Pro (data path) directories 8. Follow the instructions Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 13

Installation of Entis Pro 9. The Select the Connection Type! window will pop up 10. Choose Install stand-alone or 1st Network station 11. Follow the instructions 12. Insert the License CD in the CD-rom drive 13. Locate the license configuration file (browse to a different location if required) 14 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Installation of Entis Pro 14. The Licence screen will pop up. 4. Enter the Site name 5. Enter the Software ID number (printed on the diskette or CD label) 6. Press OK to continue 7. Follow the instructions 8. When the installation of Entis Pro is finished open the Explorer Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 15

Installation of Entis Pro 9. Select Tools 10. Select Folder Options 11. Select TAB View 12. Select Show hidden files and folders 13. Disable Use simple file sharing 14. Click on OK 15. Select the...\documents and Settings\All Users\Application Data\ ENRAF\Entis Pro folder via the Explorer 16. Select folder Properties 17. Select TAB Security and click on Add 18. Type the name of the previous created group (i.e. L_Entis Pro) 19. Click on OK and OK 16 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Installation of Entis Pro 20. Set all permissions for this group, except Full Control and Special Permissions. 21. Press Apply and OK Entis Pro is now installed, but not configured. Security settings are only available when the NTFS file system is installed and Use simple file sharing is disabled. Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 17

Entis Pro configuration 1. Start Entis Pro via the START button 2. Log on via the Key in the System Tray (lower right corner of the screen), by clicking the right mouse key 3. Enter Superuser as name and ENRAF (in Upper case) as password CIU Plus Links 1. Start CIU Plus Links via the Start menu (All Programs Entis Pro) 18 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Entis Pro configuration 2. In CIU Plus Links select the Station, expand the tree (press the plus sign). The station name will be displayed. Define New Stations This procedure is only required for a network installation. The station names of the other Entis Pro stations have to be created on the configuration station. 1. Select Stations 2. Press New 3. Enter the New Station name (Windows XP Professional computer name) 4. Press OK 5. Repeat this procedure for every Entis Pro station in the network A network alarm will pop up. Press Ack. The alarm and the window will then disappear. Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 19

Entis Pro configuration CIU COM Ports All serial communication ports that are going to be used for communication to CIU Plus s and host 45E hosts must be defined. In case of a network, this must be done for all stations in the Entis Pro network. 1. Select the Station you want to add a COM Port. 2. Press New button 3. Select required Com port and press OK. For an overview of available ports check via the Control panel, System, Hardware, Device Manager, Ports. (Do not change any settings in this panel.) Define CIU Plus host port links The connected CIU plus units have to be linked to serial ports. Use this procedure for COM Ports with CIU Plus links. Comports for host links must also be created in CIU Plus links. Host settings (45E) are configured via Host Configuration on the local stations. Open the Explorer, select the properties from the Data folder :\ Documents and Settings\All Users\Application Data and remove the Hidden attribute to ensure that CIU Plus Links can locate the Ensite Pro INI files. 1. Select Com port # 2. Press Browse and select the INI files folder created by Ensite Pro for your site 20 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Entis Pro configuration 3. Press OK 4. Select the CIU Plus Host Port from the Available pane The CIU Plus Links screen will show all 4 CIU Plus host ports in the Available pane. Be sure you select the correct one. In case of doubt this can be checked via Ensite Pro. 5. Press right arrow button 6. Press Apply and Confirm 7. Repeat this procedure for all Com Ports and CIU Plus Host ports (also for CIU Pluses used on other stations in the Entis Pro network). 8. Close CIU Plus Links. After installation a CIU communication alarm will pop up. Acknowledge and proceed. Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 21

Entis Pro configuration Tank Access Profile 1. Start Tank Access Profile via the Start menu Entis Pro 2. Expand the Stations tree (press the plus sign) 3. Select the computer (Windows XP Professional computer name) where CIU Plus units are connected. 4. Select all tanks in the middle pane (Ctrl-a) 22 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Entis Pro configuration 5. Press right arrow button 6. Press Apply and confirm. 7. Repeat this procedure for all Entis Pro stations in the Entis Pro network. 8. Close Tank Access Profile In case you do not want all tanks to be displayed, select only the tanks required. Alarms of not selected tanks will not be annunciated on that station. Define View 1. Start Define View via the Start menu Entis Pro 2. Select Views Select view 1. Press new 2. Type a view name 3. Expand the Views tree (press the plus sign) Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 23

Entis Pro configuration 4. Select the view 5. Select the required entities in the middle pane (Available Entities). 6. Press the right arrow for each required entity. 7. Select Font. 8. Apply 9. Select the Statuses tab 10. Enable the statuses you want to be displayed. 11. Apply 12. Close Define View The Defined Views are applicable for all stations in the Entis Pro network. 24 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Entis Pro configuration Import view 1. Select Import 2. Select already defined views (View definitions.ini) 3. Continue with step 5 at previous section: Select view Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 25

Installation of additional Network stations Before installing additional network stations Entis Pro is the first station and the network must be operational. (See appendix A) For each station in the network follow the instructions given in sections Windows XP Professional system settings, and Installation of Entis Pro When installing Entis Pro on an additional network station, select on the Select the Connection Type window: Install additional station. Follow the instructions. 26 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Reconfiguration of an Entis Pro network station For reconfiguring of an Entis Pro network it is important to follow the following procedure to ensure the integrity of the system. Reconfiguration is required in the following cases: Adding or removing a polling station Removing of a viewing station Adding or removing of a COM Port Adding or removing a CIU Plus Adding or removing tanks (via Reload) Changing the Hot standby configuration When executing one of these changes proceed as follows: 1. Shut down and uninstall all additional Entis Pro stations of the network (with the exception of the configuration station.) 2. Follow the instructions as described in this Installation Guide (depending on the changes you want to execute). 3. When re-configuration is finished on the configuration station Install Entis Pro again on all additional network stations In case of adding new CIU+ or tanks make a new Tank Access Profile for all station. Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 27

Backup We advise to make a backup copy of the Entis Pro database, once you are satisfied with the configuration. 1. Shut down Entis Pro via the Log on menu. 2. Open..\\Documents and Settings\All Users\Application Data\ ENRAF\Entis Pro\Database 3. Make a copy of the file: ENTISPro_Configuration.mdb. Suggested name to use is : Copy of ENTISPro_Configuration (ddmmmyy).mdb 28 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

How to Uninstall 1. Log on as an Administrator 2. Close Entis Pro via the Log on menu. 3. Open Control panel 4. Select Add or Remove programs 5. Select Entis Pro 6. Click on Remove 7. Confirm and proceed instructions 8. Click Finish to complete the un-install. 9. After un-install files like EntisPro_Configuration.mdb, logging, events and syslog files will remain available. Do not remove shared files. When installing a newer compatible version of Entis Pro, do not remove the files in the data path:...\documents and Settings\All Users\Application Data\ ENRAF\Entis Pro (Log, Event, Entis Pro configuration database). 10. Open with the Explorer:...\Documents and Settings\All Users\ Application Data\ENRAF\Entis Pro\ 11. When Entis Pro data is not used anymore, delete the part:...\enraf and its sub-directories with the data files. 12. Restart the computer. Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 29

AppendIX a Windows XP Professional Network installation This installation procedure refers only to dedicated networks. When Entis Pro is part of an existing network please consult your network administrator. Windows XP Network Setup For an isolated Entis Pro network, use the Network Setup Wizard to configure an isolated LAN (Control Panel - Network and Internet Connections - Network Setup Wizard) Make the following selections: Select a connection method: other Other Internet connection methods... This computer belongs to a network that does not have an Internet connection. Enter the Workgroup name. File and Printer sharing: Turn on file and printer sharing You re almost done... Just finish the wizard Follow the same procedure on the other Entis Pro stations in the network. Configure the IP address Open Control Panel Double click Network Connections Right click Local Area Connection Press Properties. Double click Internet Protocol (TCP/IP). Select Use the following IP Address Enter the required IP address. For example: 192.168.0.10-192.168.0.15 Enter the Subnet Mask number 255.255.255.0 Press Apply In case of DHCP contact your Network administrator. 30 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

Appendix B Network Configuration form Network Configuration form COM Port Computer name 1 2 3 4 5 6 8 9 10 Computer Name This name can be retrieved as follows: Open Control Panel Double click on System. Select the Computer Name TAB View/edit the computer name. COM Port To retrieve an overview of the available ports on a station proceed as follows: Open Control Panel Double click on System. Select the Hardware TAB Click: Device Manager Expand the Ports tree to show all available ports. Part No.: 4416614 - Revision 3 Installation guide Entis Pro version 2.50x 31

Appendix C Related documents Configuration manual Entis Pro User Guide Entis Pro 45E Host communication manual Instruction manual series 880 CIU Prime Instruction manual series 880 CIU Plus Instruction manual CIU Prime type 880 (CIU emulation) Instruction manual Modbus TM protocol Installation Guide Ensite Pro Instruction manual Ensite Pro configuration tool 32 Installation guide Entis Pro version 2.50x Part No.: 4416614 - Revision 3

For More Information To learn more about Honeywell Enraf s solutions, contact your Honeywell Enraf account manager or visit www.honeywellenraf.com. Americas Honeywell Enraf Americas, Inc. 2000 Northfield Ct. Roswell, GA 30076 USA Phone: +1 770 475 1900 Email: enraf-us@honeywell.com Asia Pacific Honeywell Pte Ltd. 17 Changi Business Park Central 1 Singapore 486073 Phone: +65 6355 2828 Email: enraf-sg@honeywell.com Europe, Middle East and Africa Honeywell Enraf Delftechpark 39 2628 XJ Delft The Netherlands Phone: +31 (0)15 2701 100 Email: enraf-nl@honeywell.com 4416614_Rev.3-ENG December 2009 2009 Honeywell International Inc.