Cascade HC/HFC - CO2 system How to control the system

Similar documents
Transcritical CO2 booster system How to control the system

Why and How we Use Capacity Control

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

Wiring Diagram. Diplomat 400V 3N.

Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

ECOCIAT. Domestic hot water heat recovery unit

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Alco Controls. Electronic Control. Conventional Control. Page. Electrical Control Valves 5. Electronic Controllers and Sensors 31

Controller for temperature control - EKC 102 REFRIGERATION AND AIR CONDITIONING. Manual

How Ground/Water Source Heat Pumps Work

A/C refrigerant system, overview

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Natural geothermal energy.

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Automation of Commercial Refrigeration Plant

Failure code manual. content

HEATER, AIR CONDITIONING AND VENTILATION

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

How does solar air conditioning work?

Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

System Trouble Shooting Fault Location REFRIGERATION AND AIR CONDITIONING. Fitters notes

SMM. Installation Operation Maintenance

Research on the Air Conditioning Water Heater System

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance

Condensing unit type EPSILON-ECHOS LE Technical information manual

Application Engineering

MP-4000 Alarm List (Software version or later)

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Heat Recovery In Retail Refrigeration

Refrigeration Basics 101. By: Eric Nelson

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Optimization of combined heating and cooling in Supermarkets

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30,

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

AK2-SC 255 Rack Controller System Reference Manual

D A T A S H E E T. TX3 Thermo Expansion Valves. Alco Controls TX3. Features. Introduction. Description of bulb charges

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Technical data. Danfoss DHP-A

Solenoid valves Type EVU

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Guide to Good Commercial Refrigeration Practice. Part 2. System Design and Component Selection

TRAINING, EXAMINATION AND CERTIFICATION

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

DIABLO VALLEY COLLEGE CATALOG

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

New Trends in the Field of Automobile Air Conditioning

Electronically Controlled Clutchless or Variable Drive Compressors

How To Understand Evaporator

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Test Report issued under the responsibility of:

Waste Heat Recovery through Air Conditioning System

Inverter and programmable controls in heat pump applications

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Air conditioning, electrical testing

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

Experimental Analysis of a Variable Capacity Heat Pump System Focusing on the Compressor and Inverter Loss Behavior

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

Designed for multi-injector endurance testing, the

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

CGC s Hybrid System Loop Control

Refrigeration Air Dryers. Catalogue

marine/bespoke split applications

User manual. Solid (FR 98,),

Testing methods applicable to refrigeration components and systems

Diagram of components 2. Reducer..3

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

Daikin Altherma hybrid heat pump. The natural combination

Basic Technology Series

UNDERSTANDING REFRIGERANT TABLES

ARP Food Industry, Portugal

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Air Conditioning 101. STN Presentation AC101

Air Conditioning Systems Warranty Manual. Version 1.8

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

PANASONIC TROUBLE SHOOTING GUIDE

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Adjustable room thermostat for heating only or cooling only systems

Transcription:

Application guide Cascade HC/HFC - CO2 system How to control the system Danfoss R64-2050.11 EKC 313 DCR GD/DGS AKS 2050 ETS EVR AK-SC 255/ AK-SM 350/ AK-SM 720/ AKA 245 AK-CC 450 AKS 2050 Pump EVRH SGN AKS 32 R DCR AK-CC 550 A GD/DGS AKVH www.danfoss.com/co2

General description Cascade systems are typical not used in FR applications with traditional refrigerants. There are a few reasons for this such as the need to maintain two different refrigerants in one system; system control strategy (especially that of a cascade heat exchanger) is more complex. At the same time using CO2 in cascade systems gives a number of advantages: Efficiency of the system is high even in the hot climates Only a small amount of refrigerant is needed for high temperature stage Temperature difference for cascade heat exchanger is relatively low On the high side various refrigerants can be used ex HC/HFC or NH3. Ammonia/CO 2 cascade systems have the highest efficiency of all. If HFC is to be used at a high temperature stage, R134a is a preferable option due to its thermo dynamical properties and lower (compared to R404A) GWP potential. Temperatures and pressures in cascade systems Intermediate temperature in a cascade system is selected based on the required temperature for high temperature cases in a store which means they can be cooled by CO2 directly. Intermediate temperature can also be optimised for the highest energy efficiency if the system is used for low temperature only. Since a cascade system actually consists of two different refrigeration systems which are interfaced but isolated at the cascade heat exchanger, the design working pressure for each can be different. CO2 design pressure is normally based on the availability of components and is equal to 40-45 bar (corresponding to +5 - +10 C). In order to prevent pressure from increasing above the previously mentioned measurements, standstill systems are recommended. Safety valves should have the highest setting. Stand still pressure can be achieved by raising the desing pressure to 80-90 bar. EKC 313 AK-CC 450 For example: CO2 side System design working pressure (saturated suction temperature): 40 bar (+5 C) Safety valve settings: 36 bar (-10% MWP) System emergency relief setting: 34 bar (-1 C) CO2 discharge pressure setting: 30 bar (-5 C) The higher the efficiency of the cascade heat exchanger, the lower the difference between the condensation temperature of CO2 and the evaporating temperature of the refrigerant on the high temperature side. As the temperature difference on the cascade condenser increases, the overall efficiency of the refrigeration system decreases! AK-CC 550 2 Application guide RA8AB102 Danfoss 10/2010 Cascade HC/HFC - CO2 system

Temperatures and pressures in cascade systems (continued) On systems with low temperatures of the discharge CO2 gas (low superheat), the superheat of the expansion valve can be the dimensioning factor for the heat exchanger. If a CO2 system has high superheat, then desuper-heaters need to be used in order to reduce the load on the high temperature side. Optimal intermediate pressure in CO2 cascade systems depends on a number of parameters (high temperature refrigerant, load pattern etc.). Generally 2 cases need to be considered: 1) Systems with load at the medium temperature. In this case intermediate pressure should be as high as possible in order to reduce the load at the high temperature stage. The limitations are therefore required temperature on the intermediate level and pressure rating of the system. 2) Systems without load at medium temperature. In this case the intermediate temperature should be in the range of -10-0 C (due to the high pressure of the CO2 LT) where lower limit is defined by efficiency and higher by system pressure rating Operating sequence of cascade systems In Cascade Systems, it is essential that at least one compressor in the high temperature side is running before the first compressor in the low temperature side can start. Otherwise, the compressor in the low temperature side may be cut out due to high pressure. The same sequence is also valid for filling up the system. First of all, the high temperature circuit needs to be filled with refrigerant and started up. When this is done, the CO2 can be filled into the low temperature system. The high temperature expansion valve (ETS) to the cascade heat exchanger should begin simultaneously with the high temperature compressors. After this, the valve controls the superheat of the high temperature gas. LT compressors are then started up by the CO2 pressure increase on the suction line. Danfoss pack controllers such as AK-PC 740 and AK-PC 780 are specially designed with built in control functions to coordinate these operations. Injection into cascade heat exchanger Injecting liquid into a plate heat exchanger is not a trivial matter. The heat exchanger is often compact and therefore the time constant is very low. AKV valves are not recommended for this application. It is recommended to use motor valves or other valves that give constant flow. Desuper-heating of CO2 gas entering the cascade heat exchanger can also be recommended for three reasons. One reason is that the gas is often 60 C and therefore the heat can be rejected to the ambient or used for heat recovery without problems. The second reason is to reduce thermal stress in the heat exchanger. The third reason is that the CO2 gas gives very high heat fluxes which therefore create unstable conditions on the evaporation side. Therefore it is recommended to reduce the superheat on the CO2 side. Distribution on the CO2 side is also a critical issue. This is why the heat exchanger has to be designed for direct expansion to make sure the mixture of gas and liquid is evenly distributed to the heat exchanger. When the heat exchanger is designed for reasonable pressure drop at part load, the oil transport and distribution should work under most conditions. Cascade HC/HFC - CO2 system Application guide RA8AB102 Danfoss 10/2010 3

Danfoss R64-2050.11 EKC 313 DCR GD/DGS AKS 2050 ETS EVR AK-SC 255/ AK-SM 350/ AK-SM 720/ AKA 245 AK-CC 450 AKS 2050 Pump EVRH SGN AKS 32 R DCR AK-CC 550 A GD/DGS AKVH Cascade HFC - CO 2 system 4 Application guide RA8AB102 Danfoss 10/2010 Cascade HC/HFC - CO2 system

Controls of Cascade system Control of cascade systems can be divided into: Condenser capacity control Compressor capacity control Cascade injection control MT evaporator CO2 flow control LT evaporator injection control Condenser capacity control Capacity control of the condenser can be accomplished via step regulation or speed control of the fans. As regulating sensor for the capacity distributor the condenser pressure should be selected. The reference for the regulation can be defined in two ways. Either as a fixed reference or as a reference that varies according to the outdoor temperature. The reference for the condensing pressure is set in C ( F). Cap. reqquest Cap.release Compressor capacity controls Pack controller AK-PC 740 (up to 4 compressors) or AK-PC 780 (up to 8 compressors) controls the LT suction pressure and is a standard controller for controlling one suction group in any refrigeration system. The controller is capable of regulating variable speed of two compressors combined with one-step compressors of the same or different sizes, depending on the choice of coupling pattern. A unique feature in the make it possible to use the Pc pressure in the LT CO2 side as control sensor for the HT suction pressure. This to ensure fast and stable control of the condensing pressure of LT CO2 side. Low-pressure / high-pressure coordination The is also able to coordinate the LT and HT start to ensure a smooth operation. Here the high-pressure compressors can start either as a result of: - Load on the high-pressure circuit - Requirements from the low-pressure circuit HT comp. release output HT comp. request input The high-pressure circuit will still ensure that the low-pressure circuit is only permitted to start when at least one high-pressure compressor has started. It will also ensure that security timers and compressor timers are complied with. LT comp. release. input LT comp. request output Here both a relay output and an On/off input are used on both controllers. Oil Management / Oil equalisation The build in oil management system covers most systems found on the market to day. Can be used with CO2 as well as all other conventional refrigerants and support input signals from : Level switch on compressor Level switch on oil separator Level switch on oil receiver Pressure transmitter on oil receiver Oil supply to the compressors is managed by activating solenoid valves with user defined ON/ Off pulse sequences. Cascade HC/HFC - CO2 system Application guide RA8AB102 Danfoss 10/2010 5

Cascade injection control In systems with cascade regulating and CO2 as refrigerant on the low temperature circuit EKC 313 can regulate liquid injection (by means of an ETS stepper expansion valve) into the cascade heat exchanger in one of two ways: Optimize superheat Regulate the condensation pressure at the low temperature circuit while ensuring that the superheat does not become too low. If there are no evaporators on the high temperature circuit the cascade controller should be set in control mode 1 to optimise superheat. In this application the condensation pressure on the low temperature circuit should be controlled by the compressor capacity controller in the high temperature circuit. Here the LT PC signal is received at the HT P0 input. MT evaporator CO2 flow control The air temperature in the medium temperature display cases or rooms is controlled by opening/ closing a solenoid valve/motor valve in the CO2 supply to the evaporator. The actual temperature control can take place in two ways: as ordinary ON/OFF regulation with a differential, or as modulating control (PWM) where the temperature variation will not be nearly as big as in ON/ OFF control. In a system with several evaporators supplied by the same CO2 liquid pump, modulating temperature control should be chosen as this also provides a more constant flow of CO2 to the CO2 pump. Period time, n63 LT evaporator injection control Injection control for the low temperature case and cold room evaporators is an AK-CC 550A utilizing pulse-width-modulating injection valves AKVH and patented adaptive software algorithms to optimise system performance and operation. Pressure control The Danfoss CO2 controllers have more pressure safety functions which prevents safety valves to open and hereby loss of charge. AK PC 740 pack controller A max compressor discharge pressure safety function will reduce compressor capacity 6 Application guide RA8AB102 Danfoss 10/2010 Cascade HC/HFC - CO2 system

AK-PC 740 Flexible controller for capacity control of compressors and condenser fans. Number of I/O can be extended with AK-XM extension modules. AK-PC 780 As AK-PC 740 plus: 4 compressors with up to 3 un-loaders 6 fans Max. 60 inputs/outputs Variable speed control on lead compressor and condenser fans Build in oil Management functions Release-request function for coordination between high-pressure and low-pressure compressors. 8 compressors with up to 3 un-loaders 8 fans. Max. 100 inputs/outputs. AK-CC 450 Complete refrigeration appliance control with great flexibility to adapt to all types of refrigeration appliances and cold storage rooms. For cooling with brine or pumped CO2 For use with a thermostatic expansion valve. Energy optimisation of the whole refrigeration appliance One controller for several different refrigeration appliances Natural, electric or hot gas defrost AK-CC 550A As AK-CC 450 + For cooling with Electronic expansion valve Adaptive control of superheat Adaptive defrosting based on evaporator performance AK-CC 750 Flexible refrigeration appliance controller for control of up to 4 evaporators. EKC 313 Controller for liquid injection in cascade heat exchangers with CO2 as refrigerant on the low temperature circuit. Stepper motor driver for ETS or CCM expansion valve. 0-10 V output for ICMTS valves ETS ETS is a series of electrically operated (stepper motor) expansion valve Electrically operated expansion valves for precise liquid injection in evaporators Fully balanced, providing bi-flow feature as well as solenoid tight shut-off function in both flow directions. Cascade HC/HFC - CO2 system Application guide RA8AB102 Danfoss 10/2010 7

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alternations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respecitve companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. FC-SPMC 8 Application guide RA8AB102 Danfoss 10/2010 Cascade HC/HFC - CO2 system