Automation Interface Requirements for J801 I/O Interface of a DPC III Welding System

Similar documents
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Allen-Bradley/Rockwell

Installation guide H A. HSI hardwired system interface

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Color Mark Sensor with Red or Green LED E3S-VS

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Advantium 2 Plus Alarm

CAN BUS INTERFACE. Module Information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

INSTALLATION INSTRUCTIONS

Servo Motors (SensorDAQ only) Evaluation copy. Vernier Digital Control Unit (DCU) LabQuest or LabPro power supply

Instruction Manual. For file reference, please record the following data:

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

WD-AMX Water Detection Controllers

Power Supply and Cabling Options. SmartTrak 100/101/140

Smart Sensing Solutions Since 1954

CVA Range. Control and Monitoring Facilities. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

L5354 ControlNet Communications Interface

MechoNet TM Network Interface (MNI) Specification Submittal

How to read this guide

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

DCS Input/Output Relay Card Series

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Model SETR-50 and SETR-51 Trim Tab Control

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Using the NI 17xx Smart Camera Direct Drive Lighting Controller

Digital and Analog I/O

8 Channel Status Input Panel model SIP-8

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

CMC-DN01 DeviceNet Slave Communication Card Operation Manual

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder

Automatic Telephone Dialer TD-101(W)

Applied Electronics. Commercial Dimming System UPDATE NOTICE

DUKANE Intelligent Assembly Solutions

Transmitter Interface Program

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V th November L6470 Stepper Motor Shield

Modular I/O System Analog and Digital Interface Modules

SYSTEM 4C. C R H Electronics Design

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Digital Keypad Use s Manual

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

UniPi technical documentation REV 1.1

IO-RM3 3-Stage Relay Module

Install the DeviceNet Module using the following procedure:

Digital input modules

TDAS G5-DB Hardware User s Manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

PUSH BUTTON START INSTALLATION MANUAL

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

POINTS POSITION INDICATOR PPI4

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Software Manual RS232 Laser Merge Module. Document # SU Rev A

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

AIS750 Series Alarm Annunciator

Fitting/Installation Guide - UNIVERSAL

SMEMA Surface Mount Equtpment Manufacturers Association

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

How to make a diagnostic on TeSysT to start the network?

Controller Automation, Model II+

Your Multimeter. The Arduino Uno 10/1/2012. Using Your Arduino, Breadboard and Multimeter. EAS 199A Fall Work in teams of two!

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

MSL1000 Monitored Serial Link Interface Manual V1.01

Digi-Motor Installation Guide

=============================== WARNING

ZC-24DO CANopen I/O Module: 24 Digital Outputs

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

TS2 VRack. User and Installation Manual

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

PRO PLM Installation Instructions

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR

VOIP-500 Series Phone Quick Installation Guide

INSTALLATION MANUAL XM3 Reader

Shunt lock function 3066

NC-12 Modbus Application

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

INSTALLATION GUIDE. FCC ID NOTICE

Model 201 Wiegand Touchpad Reader Installation Guide

SECTION LOW VOLTAGE LIGHTING CONTROLS

GST301. (Single Protection Zone) Operation Manual

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

SYSTEM 45. C R H Electronics Design

Product Documentation on the World Wide Web

BMW CAR-PC MONITOR MODEL SPECIFICATION BMW3/5 SERIES. Model Name : BMW-100P Paper Version : Ver 1.0

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

T7560A,B,C Digital Wall Module

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Mobile Device Power Monitor Battery Connection Quick Start Guide

ViZion Installation Guide

DMX2PWM 9 Channel Dimmer Setup Manual

EDI Distributor Control Interface Wiring and Setup Instructions

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Transcription:

- 1 - Automation Interface Requirements for J801 I/O Interface of a Welding System The welding system offers several features that are intended to communicate with automation. These features allow the automation to control and respond to events that occur during the welding process. This document will provide guidelines that will help you interface automation to a DPC welding system per s requirements. Information within this document is intended to supplement the information in the manual (Dukane part # 403-541). Topics: The J801 Pin assignments The 200-1203 Basic Interface Cable Status Output Signal Descriptions Status Output Interface Examples System Input Signal Descriptions System Input Interface Examples J801 I/O Interface 2004. All rights reserved. 11141 1

- 2 - J801 User Interface Connector The J801 User Interface connector is the primary communications link between the and user automation equipment. This connector provides status signals that can be used to monitor DPC weld data analysis results as well as timing issues related to the processing of the weld sequence. It also provides the automation with dedicated communication lines that allow the automation to control the beginning and the end of a welding sequence. Pin Number DPC Signal Name DPC Signal Type 1 Power Supply +22 VDC (0.5 amp max) 2 Ground Power Supply Return 3 Bad Part Output 4 Suspect Part Output 5 Good Part (see note #1) Output 6 Ready (see note #2) Output 7 Isolated Output Common Common Pin for Output Signals 8 Automation Input Input 9 Remote Setup Bit 0 Input 10 Cycle Stop Input 11 Hand Probe Press Inhibit Input 12 Input Common Common Pin for Input Signals 13 Remote Setup Bit 1 Input 14 Remote Setup Bit 2 Input 15 Ground Detect Input Note #1: This input can be reconfigured in the menu choices to activate during the following weld sequence event: In Dwell ( In Hold ) In Cycle Sonics On Note #2: This input can be reconfigured in the menu choices to activate during the following weld sequence event: Good Part In Cycle Sonics On Note: Please refer to the Communication section of the manual for details on reconfiguring pin 5 or pin 6 to the required status output signal. 2004. All rights reserved. 22142 2

- 3 - Pin # Conductor Color 1 Red 2 Black 3 Blue / Black 4 Green / White 5 Blue / White 6 Red / Black 7 White / Black 8 White 9 Orange 10 Blue 11 Orange / Black 12 Red / White 13 Green Black 14 Black / White 15 Green Part Number Length 200-1203 10 FT 200-1203-15 15 FT 200-1203-20 20 FT 200-1203-25 25 FT 200-1203-30 30 FT Configuring J801 system inputs and outputs to accommodate automation equipment requirements: There are four status output signals available on the J801 connector. Each of these outputs are driven by a solid state relay that creates a switch closure between the specified output pin and the Output Common pin. These pins can be configured within the DPC software menus to provide a signal that accommodates the requirements of most automation interface equipment. The activation duration of these outputs can be defined within the software: Maintained Outputs - Pulsed Outputs - This setting will produce an output signal that is maintained from the completion of a welding cycle until the beginning of the next welding cycle activation. (Factory default setting) This setting will produce an output signal that is pulsed a single time for 100 ms as the end of the welding cycle. Note: Please refer to the Communications section of the manual for further information on this feature. 2004. All rights reserved. 33143 3

- 4 - The system input and status output pins of J801 can also be configured to accommodate communications with external equipment that may require sourced signals, sinking signals (factory default), or signals with isolation. SH802 configures the system input signals and SH801 configures the status output signals. The location of these configuration shunts and the jumper position information is indicated in the diagrams below. Please review connection diagram examples within this document to confirm recommended connections for the SH801 and SH802 settings that are selected. SH801 and SH802 Rear Panel 110-3812 I/O PCB 2004. All rights reserved. 44144 4

- 5 - Status Output Signal Descriptions: Bad Part Output Suspect Part Output - Good Part Output - (J801 pin 3) This status output will activate when the data acquired during the welding sequence exceeds one of the user defined boundaries within the Bad Part Limits portion of the user setup. Please refer to the Process Limits section of the manual for further details on selecting and setting up a Bad Part Limit window. (J801 pin 4) This status output will activate when the data acquired during the welding sequence exceeds one of the user defined boundaries within the Suspect Part Limits portion of the user setup. Please refer to the Process Limits section of the manual for further details on selecting and setting up a Suspect Part Limit window. (J801 pin 5) This status output will activate when the data acquired during the welding sequence does not exceed any of the user defined boundaries within the Bad Part or Suspect Part Limits portion of the user setup. Please refer to the Process Limits section of the manual for further details on selecting and setting up a Process Limit window. In Dwell (In Hold) (J801 pin 5 redefined) This status output will activate when the DPC is processing the Hold portion of the welding cycle. Please refer to the Communications section of the manual for further details on redefining J801 pin 5. In Cycle (J801 pin 5 redefined) - This status output will activate when the welding cycle begins. If the status outputs have been set for maintained, In Cycle will deactivate when the Hold portion of the welding cycle has completed. Please refer to the Communications section of the manual for further details on redefining J801 pin 5. Sonics On (J801 pin 5 redefined) This status output will activate when the DPC produces the ultrasound welding signal that creates motion in the transducer stack assembly. Activation of this signal will occur during the Weld, Scrub, and Afterburst portions of the weld cycle. Please refer to the Communications section of the manual for further details on redefining J801 pin 5. Ready Output - (J801 pin 6) This status output will activate at the completion of the Hold portion of the welding sequence. It should be noted that the activation of the Afterburst feature and the return of the pneumatic press to the home position will occur after the activation of the Ready Output status signal. Please refer to the Process Control section of the manual for further information on the activation and use of the Afterburst feature. In addition please refer to the Communications section of the manual for further details on redefining J801 pin 6. In Cycle (J801 pin 6 redefined) - This status output will activate when the welding cycle begins. If the status outputs have been set for maintained, In Cycle will deactivate when the Hold portion of the welding cycle has completed. Please refer to the Communications section of the manual for further details on redefining J801 pin 6. Sonics On (J801 pin 6 redefined) This status output will activate when the DPC produces the ultrasound welding signal that creates motion in the transducer stack assembly. Activation of this signal will occur during the Weld, Scrub, and Afterburst portions of the weld cycle. Please refer to the Communications section of the manual for further details on redefining J801 pin 6. 2004. All rights reserved. 55145 5

- 6 - status output interface examples: The ratings for the DPC Status output pins are: Maximum Voltage Rating = +24 VDC Maximum Current Rating = 100 ma 3 200-1203 Cable PLC Bad Part 4 Suspect Part 5 Good Part 6 Ready (Factory Default) JU801 JU802 JU803 2 SH801 (Located on the 110-3812 PBC inside the DPC) Input Common Note: This diagram provides a simplified representation of the output device for the purpose of demonstrating circuit functionality. status output configuration for use with a PLC requiring sinking inputs. 2004. All rights reserved. 66146 6

- 7 - The ratings for the DPC Status output pins are: Maximum Voltage Rating = +24 VDC Maximum Current Rating = 100 ma 3 200-1203 Cable PLC Bad Part 4 Suspect Part 5 Good Part 6 Ready +22VDC (Factory Default) JU801 JU802 JU803 2 SH801 (Located on the 110-3812 PBC inside the DPC) Input Common Note: This diagram provides a simplified representation of the output device for the purpose of demonstrating circuit functionality. status output configuration for use with a PLC requiring sourcing inputs. 2004. All rights reserved. 77147 7

- 8 - The ratings for the DPC Status output pins are: Maximum Voltage Rating = +24 VDC Maximum Current Rating = 100 ma 3 200-1203 Cable PLC Bad Part 4 Suspect Part 5 Good Part 6 Ready (Factory Default) JU801 JU802 JU803 7 SH801 (Located on the 110-3812 PBC inside the DPC) Input Common Note: This diagram provides a simplified representation of the output device for the purpose of demonstrating circuit functionality. status output configuration for use with a PLC requiring isolated inputs. 2004. All rights reserved. 88148 8

- 9 - The ratings for the DPC Status output pins are: Maximum Voltage Rating = +24 VDC Maximum Current Rating = 100 ma (Factory Default)JU801 JU802 JU803 +22 VDC SH801 (Located on the 110-3812 PBC inside the DPC) Bad Part Suspect Part Good Part Ready 3 4 5 6 2 Customer Device Customer Device Customer Device Customer Device Note: This diagram provides a simplified representation of the output device for the purpose of demonstrating circuit functionality. status output configuration for use with Customer devices that exceed the maximum ratings of the status outputs. 2004. All rights reserved. 99149 9

- 10 - System Input Signal Descriptions: Automation Input - Cycle Stop- (J801 pin 8) This system input signal is activated by an external dry contact closure to the DPC Ground pin on J801 pin 2. The minimum duration for the activation of this input is 100 ms. The maximum duration of this input is determined by the duration of the weld cycle. This input should be deactivated before the end of the weld cycle to avoid an error condition (Associated Error: # E06 Auto Active at Cycle Start). The Automation Input pin can be reconfigured to accommodate sourced and isolated signals as described in the J801 pin configuration section of this document. Please refer to the Initiate Mode section of the manual for details on the activation and use of the Auto Initiate mode. (J801 pin 10) This system input signal is activated by an external dry contact closure to the DPC Ground pin on J801 pin 2. The minimum duration for the activation of this input is 100 ms. Activation of this input will end the welding cycle and return the welding system to its home position. This input must be deactivated at the beginning of a weld cycle. The Cycle Stop Input pin can be reconfigured to accommodate sourced and isolated signals as described in the J801 pin configuration section of this document. Remote Setup Bit 0,1, 2 - (J801 pin 9, 13, and 14) These system input signals are activated by an external dry contact closure to the DPC Ground pin on J801 pin 2. The minimum duration for the activation of this input is 100 ms. The binary combination produced by the three inputs will be used by the Remote Setup selection feature of the. This is an optional feature which requires supporting components. The Remote Setup Input pins can be reconfigured to accommodate sourced and isolated signals as described in the J801 pin configuration section of this document. Please refer to Appendix A and the Sequencing section of the manual for details on the activation and use of the Remote Setup feature. Hand Probe Press Inhibit (J801 pin 11) This system input is activated by an external dry contact closure to the DPC Ground pin on J801 pin 2. The minimum duration for the activation of this input is 100 ms. Activation of this input is intended to configure the DPC for probe system functionality. It will deactivate all valves for the press during a welding cycle. This system response will continue until the contact closure to the DPC ground is removed. Ground Detect - (J801 pin 15) This system input is activated be an external dry contact closure to ground. This feature is Intended for use with cutting applications. Activation of this feature indicates that the cutting edge of the horn has cut through the product. When this signal is detected, the weld portion of the cycle will be terminated. This input must be deactivated to initiate a weld cycle. Please refer to the Ground Detect and Scrub features of the manual for details on the activation and use of the Ground Detect feature. A connection example has been provided within this document for this feature. 2004. All rights reserved. 10101410 10

- 11 - Electrical Insulator Fixture Customer Product 200-1203 Cable Connect to J801 pin 15 Welding Table / Base system input configuration for the Ground Detect feature. 2004. All rights reserved. 11111411 11

- 12 - PLC 200-1203 Cable 8 Auto Initiate 9 Remote Setup Bit 0 10 Cycle Stop 11 Hand Probe Press Inhibit 13 14 Remote Setup Bit 1 Remote Setup Bit 2 Output Common Refer to Ground Detect diagram example for the Ground Detect feature. 2 15 J801 +22VDC JU804 (Factory Default) JU805 JU806 SH802 (Located on the 110-3812 PBC inside the DPC) Ground Detect system inputs for use with a PLC equipped with sinking outputs. 2004. All rights reserved. 12121412 12

- 13 - PLC +24 VDC 200-1203 Cable 8 Auto Initiate 9 Remote Setup Bit 0 10 Cycle Stop 11 Hand Probe Press Inhibit 13 14 Remote Setup Bit 1 Remote Setup Bit 2 2 JU804 (Factory Default) JU805 JU806 Refer to Ground Detect diagram example for the Ground Detect feature. 15 J801 SH802 (Located on the 110-3812 PBC inside the DPC) Ground Detect system input configuration for use with a PLC equipped with a sourcing output. 2004. All rights reserved. 13131413 13

- 14 - PLC +24 VDC 200-1203 Cable 8 Auto Initiate 9 Remote Setup Bit 0 10 Cycle Stop 11 Hand Probe Press Inhibit 13 14 Remote Setup Bit 1 Remote Setup Bit 2 JU804 (Factory Default) 12 JU805 JU806 Refer to Ground Detect diagram example for the Ground Detect feature. 15 J801 SH802 (Located on the 110-3812 PBC inside the DPC) Ground Detect system input configuration for use with a PLC requiring isolation. 2004. All rights reserved. 14141414 14