ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Similar documents
Trouble Shooting BD & TW Compressor Systems 12 and 24 Volt

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Before installation it is important to know what parts you have and what the capabilities of these parts are.

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

User Installation Guide

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

SERVICE MANUAL REFRIGERATION

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SERVICE MANUAL REFRIGERATION

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Wireless 7 Day Programmable Room Thermostat

Portable Air Conditioner

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Digital Keypad Use s Manual

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

MOUNTING AND OPERATING INSTRUCTIONS

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

FG MOISTURE MONITOR Installation & Operation Manual

4.3-inch Back-Up Camera

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Cooling system components, removing and installing

2003/2004/2005 TOYOTA COROLLA

GENUINE PARTS INSTALLATION INSTRUCTIONS

Drayton Digistat +2RF/+3RF

Control Box Wiring For PRSstandard Tool

Ceiling Fan Installation Instructions

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

Cooling system components, removing and installing

User's Instructions. Alpha HE CB25/33 and HE SY25

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

BUILT-IN WINE & BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL. Model No.: MCWBC77DZC

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

TEMPERATURE CONTROLS/ THERMOMETER/TIMERS

Document number RS-PRD Revision 05 Date 20/10/2009 Page 1/30

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

HEAT PUMP PROGRAMMABLE THERMOSTAT

Traditional Sonar and DSI Sonar Installation

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

FTDI VCP DRIVER (free) (WIN/MAC/LINUX)

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Operations Manual Blast Chiller

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L

PR 50 Frymaster Universal Holding Cabinet (UHC)

RC HELICOPTER INSTRUCTION MANUAL

REF Series Undercounter Refrigerator

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel)

site monitoring Kit Site Monitoring Kit User Manual we prove it.

INSTALLATION INSTRUCTIONS

ELECTRIC KNIFE SHARPENER

CoolWave r 2 Phase Control Board and Cable Replacement Kits


Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS


FIREDEX Conventional Fire Panels

INSTALLATION INSTRUCTIONS

Installation & User Manual Radio Remote rev1.0.3

Dehumidifier Users manual. For Models: DH45S DH65S

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Installation Instructions. Thermo Call TC3

Wiper Motor Marinco 2.5. Installation Instructions

Manual Ranging MultiMeter

PORTABLE AIR CONDITIONER

Table of Contents. 1 - Specifications Installation Wiring User controls...7

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

FOXAIR 60/50 ALL MODELS

5800 Temperature Sensor Cable Assembly

DIY Y6. Build Manual V.A 2014

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

Air conditioning, electrical testing

Audi A4 (B5) HID conversion installation instructions

Manual for Fire Suppression & Methane Detection System

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

V94 BULK TAPE DEGAUSSER

Instructional & Operating Manual

, User s Manual

Troubleshooting Guide for Dispenser Model #900172

BUSINESS. Elektronisches Türschloss. Installation and User Manual. Ingeniously safe. Ingeniously simple.

SYSTEM 4C. C R H Electronics Design

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Transcription:

148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL The Sea Frost ETT (Electronic Thermostat/Thermometer) will accurately control temperature for the best efficiency The ETT always shows cabinet temperature, and will display in Centigrade or Fahrenheit. Non-volatile memory, control will not loose settings. The ETT is pre-wired with plug in connectors for the two 10 probes and 20 data cable included. Custom lengths are available. Faceplate size: 4-5/8 x 3-½ (120 mm x 90 mm). Requires 2-½ (64 mm) clearance behind mounting panel. Weight 1 lb (.4 kilo).

CLEANING Do not use acetone or any solvent on the control panel, clean with a damp cloth and mild detergent. INSTALLATION AND OPERATION Operation The Sea Frost Electronic Thermostat and Thermometer with speed control (ETTsc) is an electronic device using two probes installed in the refrigerated space. One probe is sensing the cabinet temperature, which is displayed. The other probe controls the compressor operation by measuring the temperature of a cold plate. To operate the control, push the top of the rocker switch to turn on the temperature readout. The display will light and the temperature will be displayed. To start the compressor turn the speed control knob to desired position. There will be a slight delay before the run light turns on. Changing Speeds Speed can be changed at any time. If the compressor is running when the speed is changed, the red run light will go off and then will go back on when the compressor has adjusted to the new speed. Run Light The run light indicates the compressor is operating. When the compressor cools to the pre-set cut out temperature the run indicator light will go off with the compressor. To display temperature only, turn the compressor speed control to the off position. To turn off both the temperature readout and compressor the rocker switch may be used. All temperature settings will be saved. Error Light The yellow error light indicates a compressor fault. See page 6. THE TEMPERATURE SETTING Before adjusting the thermostat make sure the refrigeration system is working properly. The ETTsc can be adjusted and will maintain very stable temperatures. Care must be taken to adjust the settings to maintain obtainable temperatures. In initial testing do not 2

set below -10 F. ( 23 degrees C.) BDxpx models may be set lower - 20 F ( - 29 C.) Excessive compressor running will occur with no benefit if the setting is below the temperature the compressor system can easily obtain. To check the cut out setting (cold stopping point) push and hold the SEL button until ST1 appears. Release the button and a number will flash. This is the cut out temperature. Push SEL again and the readout will return to box temperature. The cut out temperature is associated with the second probe (red banded). This probe read out temperature is hidden. Press and hold the down arrow button to view this read out temperature. Plate Probe Temperature To monitor the cooling progress, push in and hold the down arrow button. The plate probe temperature will be displayed while this button is held. Recommended Settings The air temperature in a refrigerator is always 10 to 15 degrees F. (6 to 9 C.) warmer than the cooling device. This difference in temperature must be remembered when setting the control cut out temperature (stopping point). A refrigerator might have to be set to run up to 20 degrees colder than the desired box temperature. Make several small setting changes over a period of several days to determine the proper setting. Changing the Temperature To lower or raise the box temperature, hold the SEL button until the ST1 appears. Release the button and the cut out temperature will flash. Use the up and down arrows to change the temperature. Push SEL when finished. The control setting has now been changed. The Differential Setting The differential is the number of degrees the temperature must rise before the compressor will come back on after cooling to the set point. The factory test setting is 6 degrees F. (4.5 C.) To change the differential setting press and hold PRG until P 1 is displayed, then press SEL. Use the up and down arrows to change the setting. Press PRG when finished. 3

Readout Changes ~ Fahrenheit to Centigrade To change the readout to centigrade hold down PRG and SEL for 5 seconds until 0 is displayed. Using the up and down arrows select #77, which is the password. Press SEL. Using the up and down arrows scroll to C-18. Press SEL. Using the arrows keys set 0 for centigrade or 1 for Fahrenheit. Press PRG to store the change and return to the temperature display. WARNING: When changing temperature measurement units the cutoff setting and the differential setting must be changed to represent the proper units. INSTALLING THE ETTsc The ETTsc can be located anywhere as long as it is protected from water and spray. The leads to the probes may be extended to any length if the connections are soldered and sealed with heat shrink. The ETT sc requires a 3 5/8 x 2-¾ (91 mm x 70 mm) panel cut out. The minimum depth is 2-½ (64 mm). Wire Routing and Connecting The blue cat-5 cable provides power and signal for the ETTsc. It connects at the compressor. The RJ-45 connector on this cable plugs into the RJ-45 port on the Module PCB board. Make certain the plug is clean, and that the plug has not been damaged when routing through the boat, before plugging it in. If shortening this cable make sure the color code is observed. Any pre-made RJ-45 cable will work. Custom lengths are available. Fuse Install a 3-amp ATC fuse in the fuse holder on the Module PCB board on the compressor. Wiring Connections The two black probe wires must enter the refrigerated space. The probes plug into the head unit cables. NOTE: One probe has a red band and should connect to the plug with the red band on the back of the ETTsc head. The probe with the red band must be routed to attach to the cold plate, if fitted with two cold plates the probe will attach to the second plate. The second plate is the one without an expansion valve. If you need to disconnect the plugs, do not pull on the wires insert a small screwdriver blade between the halves of the plug. 4

PROBE ATTACHMENT The probe with red bands must be in excellent thermal contact with the cold plate. Use the stainless steel clip provided, and attach it to the edge of the plate as shown in the drawing to the right. The probe without a red band should be installed at the mid point of the cabinet to get an accurate reading of the average temperature. Avoid installing this probe near a front opening door or too close to a cold plate. Mount the probe bulb with two nylon straps or self stick pads and tie wraps provided. Do not drill and screw into a vacuum panel box! Secure the wires neatly using cable ties, self-stick pads, and proper yacht construction wiring practices. 5

TROUBLESHOOTING In case the electronic unit records an operational error, the fault diode will flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash lasts 1/4 second. After the actual number of flashes there will be a delay with no flashes, the sequence for each error recording is repeated every 4 seconds. Flashes will only occur in the fault mode with the system on. OPERATIONAL ERRORS SHOWN BY YELLOW LED Number of flashes Error type 5 Thermal cut-out of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). 4 Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed 1,850 rpm). 3 Motor start error (The system is overcharged). 2 Fan over-current cut-out (The fan is defective). 1 Battery protection cut-out (The voltage is outside the cut-out setting. Low voltage.) See: Separate BD/Tradewinds Trouble Shooting Data Pages on-line. 6

SEA FROST ELECTRONIC THERMOSTAT AND THERMOMETER DRILL (4) HOLES 3/32" FOR #6 SCREWS. (1) Control Panel Head (2) Sensor Probes (1-with red band, 1-without red band) (1) Cat 5 cable with RJ 45 Connector INSTALLATION KIT (4) #6 x 1/2" flat head screws for mounting panel (6) #6 x 1/2" pan head screws (5) 3/16" nylon clamps (8) Adhesive mounting tabs (10) 4" tie wraps (1) Stainless steel bulb clip (1) Fuse 7