Medium voltage insulator

Similar documents
HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

DS 600. A contact free flux gate based current measurement sensor 600A rms

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

High-ohmic/high-voltage resistors

High-ohmic/high-voltage resistors

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

Series 8146/5-V37 and Series 8150/5-V37

Transformer Bushings for GIS

CABLE ACCESSORIES kv

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

Design Test Report Veri*Lite Suspension Insulators Catalog Numbers: , , ,

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Composite Insulators Suspensions Line Posts Brace Posts Station Posts

SURGE PROTECTIVE DEVICES

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Pluggable interface relays CR-P Pcb relays

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

3-Component Measuring System

Design Test Report Report No. EU1531-H ANSI C29.18 PROTOTYPE/ CEA LWIWG 02 DESIGN TEST REPORT Silicone Rubber 69 kv Veri*Lite Line Post 80S069

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide


Transmission Silicone Insulators Line Post 69 kv to 161 kv

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

RY2 miniature industrial relays

High Ohmic (up to 68 MΩ)/ High Voltage (up to 10 kv) Resistors

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

VIPERFLEX ELECTRIC CABLE

08. SEK IDC CONNECTORS

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

ODU MEDI-SNAP. Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal.

HV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556H form A contact (normally open) for PCBs

Feed-through terminal block - SSK 110 KER-EX

HERZ-Thermal Actuators

Do s and don'ts of connection systems Are there any options when the clearance and creepage distances are not sufficient for UL 1059?

PC/104, PC/104 -Plus, VarPol connectors

High Ohmic/High Voltage Metal Glaze Leaded Resistors

V REG.-Nr , Z E Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

SMD Terminal Blocks with Push-Buttons

a Nexans company Catalogue 2014

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

High Ohmic/High Voltage Metal Glaze Leaded Resistors

Keystone Network Isolator with ESD- and Lightning Protection

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

TECHNICAL INFORMATION

Current transformers (CT) & Shunts

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Mounting Instructions. Torque Transducer. A en

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Powermate Range Pitch 7.62

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

Voltage Regulator SPAU 341 C. Product Guide

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

Spring Cage Feed-Through Terminal Blocks ST

Unified requirements for systems with voltages above 1 kv up to 15 kv

Electro-pneumatic control valves

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

Explosion proof enclosures

Technical catalogue. Modular DIN rail components Installation contactors

FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

High Ohmic/High Voltage Metal Glaze Leaded Resistors

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Analog signal converters CC-E I/I Current / current isolators

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet _en_02. 1 Description

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

ACTIV-8 PLUS Insulated Conductor Bar

Measurement and Instrumentation

How To Read A Pipe From A Sensor

Standard Thick Film Chip Resistors

ACCESSORIES FOR XLPE-INSULATED HIGH AND EXTRA-HIGH VOLTAGE CABLES

Cable Plug acc. to DIN EN , Form A

Plug-in relays Mini ISO relays

Thermistor motor protection

3FL Silicone Long Rod Insulators for Distribution and Transmission Overhead Power Lines

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Pressure transmitter For general industrial applications Model A-10

NUMERIC SIGN SP2-6XX / 100mm. Presentation

INTERNATIONAL STANDARD

ENERGY. TECWATER S1BN8-F 0,6/1 kv. Cable for Water Application

Linear Luminaire with LED Series EXLUX 6402/2

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Current distribution Comb busbars for Declic and SFT residential devices

SESD Series Ultra Low Capacitance Discrete TVS

Installation Guide. DEVIreg 530. Electronic Thermostat.

Transcription:

Medium voltage insulator Line post insulators type R-ET Commercial designation LPI 24 N ET 1) LPI 24 L ET/5 1)2) LPI 24 L ET/6 1)2) LPI 38 L ET 1) esignation acc. to IEC 720 R 12,5 ET 125 N R 12,5 ET 125 L R 12,5 ET 125 L R 12,5 ET 170 L Rated insulation (kv) 24 24 24 36 Minimum bending failing load (kn) 12,5 12,5 12,5 12,5 Lightning impulse withstand voltage (kv) 125 125 125 170 Wet power frequency withstand voltage (kv) 50 50 50 70 Minimum nominal creepage distance (mm) 400 530 530 720 imensions (mm) H ±8% 305 305 305 370 max 160 170 170 180 min d 100 100 100 110 No. of ribs 5 5 6 6 Glaze colour BROWN - RAL 8011, 8016, 8017 Testing standard IEC 383 1) LPI 24 and 38 insulators are available with or without a clamp. 2) R 12,5 ET 125 L insulator made to client requirement with either 5 or 6 ribs. 178 178 Line post insulators type R-EC Commercial designation LPI 24 N NG LPI 24 L NG LPI 38 L NG esignation acc. to IEC 720 R 12,5 EC 125 N R 12,5 EC 125 L R 12,5 EC 170 L Rated insulation (kv) 24 24 36 Minimum bending failing load (kn) 12.5 12.5 12.5 Lightning impulse withstand voltage (kv) 125 125 170 Wet power frequency withstand voltage (kv) 50 50 70 Minimum nominal creepage distance (mm) 400 530 720 imensions (mm) H ±8% 350 350 420 max 160 170 180 min d 100 100 110 Glaze colour brown RAL 8011, 8016, 8017 Testing standard IEC 383 ATA 142

Pin insulators type VH and VH-PbSb esignation acc. to IN 48004 VH 10 VH 15 VH 20 VH 20-PbSb VH 25* VH 25*-PbSb Rated insulation (kv) 12 17.5 24 24 24 24 Low frequency withstand voltage (kv) dry 55 60 80 80 80 80 wet 40 45 65 65 65 65 Lightning impulse withstand voltage dry (kv) pos 110 110 150 150 150 150 neg 145 145 190 190 190 190 Puncture voltage (kv) 120 120 150 150 150 150 Minimum nominal creepage distance (mm) 195 280 384 384 435 435 Breaking load (kn) 12.5 12.5 15 15 15 15 imensions (mm) H 130 150 185 185 215 215 h 1 32 36 57 57 70 70 h 2 55 60 65 55 +5 80 70 +5 h 3 82 95 123 123 150 150 135 150 175 175 205 205 d 1 70 78 83 +4 83 +4 83 +4 83 +4 d 2 28 +3 28 +3 31 +4-32 +4 - d 3 31 +4 31 +4 35 +4-37 +4 - Glaze colour brown RAL 8011, 8016, 8017 Testing standard IEC 383 * VH 25* insulator made to client s requirements. VH PbSb insulator with or without a clamp. 143 ATA

Post insulator for outdoor mounting type FSAR esignation acc. to IN 43632 FSAR 10 FSAR 20 FSAR 30 Rated insulation (kv) 10 20 30 Minimum bending failing load (kn) 6 6 6 Lightning impulse withstand voltage (kv) 75 125 170 Wet power frequency withstand voltage (kv) 28 50 70 Arcing distance (mm) 180 260 360 imensions (mm) d 1 80 90 100 d 2 140 150 160 d 3 105 116 128 H 1 285 375 490 H 2 165 245 344 H 3 60 65 73 Number of ribs - n 3 4 5 Glaze colour Brown RAL 8011, 8016, 8017 Test standard IEC 168 Post insulator for outdoor mounting type C esignation acc. to IEC 273 C4-125 Class I Commercial designation **C4-125 Class II Rated insulation (kv) 24 24 Wet power frequency withstand voltage (kv) 50 50 Withstand lightning impulse voltage (kv) 125 125 Nominal creepage distance (mm) 380 520 Mechanical failing load (kn) Bending (kn) 4 4 Torsion (knm) 0.8 0.8 Glaze colour Brown RAL 8011, 8016, 8017 Test standard IEC 168 and IEC 383 ** Insulator made according to customer specifications (ceramic and metal part). Line pin insulators type EKO 24 Commercial designation EKO 24 PbSb Rated insulation (kv) 24 Cross-section semi insulated Al conductor 35-70 mm 2 Wet power frequency withstand voltage (kv) 50 Lightning impulse withstand voltage (kv) 125 Nominal creepage distance (mm) 384 Breaking load (kn) 12.5 Glaze colour Brown RAL 8011, 8016, 8017 Test standard IEC 383 ATA 144

Low voltage insulator Pin insulators type N esignation acc. to IN 48150 - N95 Commercial designation N-80 N-95 Rated insulation (kv) 1 1 Minimum bending failing load (kn) 12 18 imensions (mm) A 85 97 B 38 41 C 31 35 80 95 E 42 50 F 21 24 Glaze colour Brown RAL 8011, 8016, 8017 or white Test standard VE 0446 Shackle insulators type S Commercial designation Z-80 Z-115 esignation acc. to IN 48154 S-80 S-115 Rated insulation (kv) 1 1 Minimum bending failing load (kn) 12.5 20 imensions (mm) A 80 115 B 45 65 C 22 32 80 115 E 26 38 F 57 80 Glaze colour Brown RAL 8011, 8016, 8017 Test standard VE 0446 Strain insulator type E esignation acc. to IN 48156 E-100 Rated insulation (V) 500 Minimum bending failing load (kn) 62 Glaze colour Brown RAL 8011, 8016, 8017 Test standard VE 0446 145 ATA

Tension insulator ZI 24 Ball Ball 75,6 75,6 79 19,2 79 19,2 ø17 ZI 24 Ball Socket Electrical and mechanical characteristics type length (mm) min. surface insulation distance (mm) max. tension load (KN) longitudinal atmospheric impulse voltage 1.2/50 μs (KV) industrial frequency constant voltage in the rain 50Hz (KV) N 240 520 70 125 50 1.0 gray L 340 765 70 170 70 1.1 gray The insulators are manufactured in accordance with the standard IEC 61 109 weight (kg) colour ZI 24 Socket Socket ZI 24 Ball Eye 75,6 68 50 ø17 ø17 ø16 Electrical and mechanical characteristics type length (mm) min. surface insulation distance (mm) max. tension load (KN) longitudinal atmospheric impulse voltage 1.2/50 μs (KV) industrial frequency constant voltage in the rain 50Hz (KV) N 240 520 70 125 50 1.0 gray L 340 765 70 170 70 1.1 gray The insulators are manufactured in accordance with the standard IEC 61 109 weight (kg) colour ATA 146

ø16 Technical data - INSULATORS ZI 24 AA/N-v 68 50 ø16 ZI 24 AA/L-90 50 68 Electrical and mechanical characteristics type length (mm) min. surface insulation distance (mm) max. tension load (KN) longitudinal atmospheric impulse voltage 1.2/50 μs (KV) industrial frequency constant voltage in the rain 50Hz (KV) N 240 520 70 125 50 1.0 gray L 340 765 70 170 70 1.1 gray The insulators are manufactured in accordance with the standard IEC 61 109 Note: v - parallel clamping 90 - right-angled clamping weight (kg) colour 147 ATA