Guard locking systems for the protection of man and machine

Similar documents
Safe switching and monitoring Solenoid Interlocks

SMS 4 / SMS 5 safety mat Product information

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04

Safety detection solutions

Safety automation solutions

Safety Relays ESM/ESM-F

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

Data Sheet. Electro-mechanical counters Hengstler 800 series

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Machine Safety Switches

Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

PNOZsigma - Base units

mecotron Safety relay ESTOP-2 For emergency stop monitoring

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

E-STOP relays, safety gate monitors

Preventa Machine Safety Products

Modular I/O System Analog and Digital Interface Modules

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

SKR - industry relay

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Machine Safety Switch: SI-LM40 Series Limit Switch Style

HERZ-Thermal Actuators

Description. Dimensions. Features. precision works better

General 1-2-Opto-electronics Safety Switches 4-Emergency

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Inductive sensor NI10-M18-Y1X-H1141

38 Series - Relay interface modules A

Safety technique. Emergency stop module BO 5988 safemaster

Common Features of Electromechanical Switches

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

38 Series - Relay interface modules A

40.3. Control Relays and Timers

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Cross-beam scanning system to detect slim objects. 100 mm in

Speed Control Relays SX2

Series 8146/5-V37 and Series 8150/5-V37

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Product Information Sheet UH28CS-12kV Hi Pot Tester

DALI RC BASIC SO. Control unit Operating instructions

TS93 EMR T/PT/TDE. Surface applied door closer

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

FIREDEX Conventional Fire Panels

E-STOP relays, safety gate monitors

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Power Supplies 3. SDN-P DIN Rail Series

E-STOP relays, safety gate monitors

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Duct Humidity Transmitter

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Product Information Sheet UH36 Hi Pot Tester

Pressure Switch for gas and air

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Programming Logic controllers

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Electric Rotary Actuator - On/Off or programmable control actuator

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Contact expansion modules

E-STOP relays, safety gate monitors

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

08. SEK IDC CONNECTORS

Circuit Breakers. NRC Series. NRC Series

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

EUROMAP 78. Electrical Interface between Injection Moulding Machines and External Safety Devices. Version 1.0, November pages

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

W150: Miniature photoelectric switch series with completely integrated electronics

Digital display DA 48

Application Technique. Safety Function: Magnetic Door Switch Monitoring

E-STOP relays, safety gate monitors

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

DMX2PWM 9 Channel Dimmer Setup Manual

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Thermal-Magnetic Circuit Breaker M1-..

ED 100LE ED 250LE. Low energy swing door operators

Electronic overload relay EF19 and EF45

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

MINI MCR-SL-R-UI(-SP)

Electro-pneumatic control valves

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system

Transcription:

Guard locking systems for the protection of man and machine

K. A. Schmersal GmbH Safety Control Systems Möddinghofe 30 D - 42279 Wuppertal P.O. Box 24 02 63 D - 42232 Wuppertal Germany Phone +49 - (0)2 02-6474- 0 Fax +49 - (0)2 02-6474- 1 00 E-Mail Internet info@schmersal.de www.schmersal.com Elan Schaltelemente GmbH & Co. KG Im Ostpark 2 D-35435 Wettenberg Germany Phone +49 (0)641-9848 - 0 Fax +49 (0)641-9848 - 420 E-Mail info@elan.schmersal.de Internet http://www.elan.de

Table of contents Introduction Operator and process safety Page 4 Installation and operating solenoid interlocks Page 5 Product 1. Solenoid interlock devices Page 15 2. Door handle switch Page 22 3. Safety control modules Page 24 4. Fail-safe standstill monitors Page 26 5. Wiring diagrams Page 29 6. Terminal definition Page 53 Appendix 7. Glossary Page 54 8. Symbols Page 58 9. References Page 59 3

Operator and process safety EN 1088 Most machine guarding on industrial machinery is fitted with guard-locking safety interlocks (solenoid interlocks). This has two reasons: Firstly, EN 1088 requires that hazardous areas on machinery and plant remain inaccessible until all dangerous machine movements have stopped. This can be achieved by installing a solenoid interlock on movable machine safety guards. Secondly, solenoid interlocks also serve to safeguard the process: any unauthorised intervention in the running processes or any unexpected machine stop by an unforeseen opening of a safety guard is avoided. For example, a solenoid interlock can ensure that a robot completes its entire cycle before it stops. Moreover, solenoid interlocks can prevent damage to a machine tool through an unexpected stop, thus helping to ensure maximum productivity. In addition, solenoid interlocks can also help meet the safety requirements defined in EN 1037, i.e. the protection against unexpected start-up of machinery. The Schmersal Group offers its customers the largest program of safety control systems for the protection of man and machine, in particular a large range of solenoid interlocks and intelligent accessories that facilitate the integration of solenoid interlocks into the user s application. The program includes door handle switches, mounting sets and a large range of actuators, suitable even for small actuating radii. Together with fail-safe standstill monitors and safety control modules, complete system solutions can be configured. This brochure contains a short overview of the individual product lines and the main accessories available within the Schmersal Group for guard locking applications. The technical data for the individual devices are complemented by wiring diagrams, which show how simply Schmersal components can be wired together into a complete system. 4

Installation and operating solenoid interlocks The Schmersal guardlocking safety interlocks are based on the principle of the separate actuator (Fig. 1): The actuating element (the actuator or key ) is fitted to the movable part of the machine guard (usually a safety guard). The solenoid interlock itself is mounted to the stationary part of the guard, for example the door post. The machine can only start when the actuator (mounted on the moveable guard) has entered the solenoid interlock and is locked in position. To optimise the benefits of this principle, some basic rules for the design of the machine guard and interlock mounting, as well as during machine operation, must be observed. The following pages contain practical hints and advice on mounting and operating solenoid interlocks. Fig. 1: Solenoid interlock AZM 170 with separate actuator 5

Installation and operating solenoid interlocks The safety Solenoid interlocks should be fitted near the door handle For trouble-free guard locking, it is imperative that the actuator smoothly enters the solenoid interlock throughout the guard s intended lifetime. To achieve this, the safety guard must have a degree of stability that does not allow torsion or doorsetting. In addition, it is recommended to fit the safety guard handle as close as possible to the solenoid interlock. This ensures that the actuator can always be easily extracted or inserted into the solenoid interlock, even in case of a deformed or distorted safety guard (see Fig. 3). Fig. 2: Door handle switch TG with AZM 190 Fig. 3: Positioning of the solenoid interlock and door handle on a safety guard 6

guard End stop for heavy safety guards fit a damper against rebound The solenoid interlock must not be used as mechanical end stop or as a guide for the safety guard. A separate end stop is required. Even with an end stop, the rebound from a heavy safety guard can lead to serious damage to the solenoid interlock and/ or actuator if, upon closing the door, the solenoid latches the actuator into the locked position. To prevent this, a damper can be fitted to the door. All in one: door handle switch TG For larger machines and assembly lines which have many safety guards, a separate unlocking button should be fitted near or on each safety guard to enable individual guard unlocking. In this way, the operator does not need to go to the machine control panel and unlock all safety guards; but can unlock and lock only the safety guard required. The door handle switch TG developed by the Schmersal Group features a door lock control button with integrated LEDs to indicate if the safety guard is locked or released. This ergonomic aspect helps deter the operator from prematurely pulling on the door and jamming the unlocking mechanism. An emergency stop button can also be integrated into the door handle switch where required (Fig. 2). Actuator: fixed or flexible? The size of a hinged guard can limit the operating radius of the actuator. To guarantee smooth insertion of the actuator into the solenoid interlock in such cases, the Schmersal Group offers a large range of actuators specially designed for small actuating radii. On hinged guards the use of flexible adjustable actuators is recommended; for sliding guards, fixed actuators are more suitable (Fig. 5). We recommend attaching the actuator inextricably to the safety guard, for example using one-way screws to avoid the actuator being removed for unauthorised use. As an alternative the actuator can be fitted in a concealed position, which also minimises the risk of injury from the actuator (Fig. 4). Fig. 4: Concealed mounting Fig. 5: Fixed and flexible actuator 7

Installation and operating solenoid interlocks The solen Operating principle: spring to lock or power to lock? All solenoid interlocks developed by the Schmersal Group feature a fail-safe locking mechanism. This design feature, described in EN 1088, means that the solenoid locking bolt can only lock after the actuator has entered the interlock i.e. the safety guard is closed. This means that the safety circuit can be enabled using the solenoid contacts only. The actuator contacts are used solely for position indication of the safety guard. Since solenoid interlocks featuring a fail-safe locking mechanism offer a higher degree of safety, the installation of a second device for monitoring safety guard position can be left out under certain circumstances (see page 28). Solenoid interlocks have two different operating principles: Solenoid interlocks with spring to lock are locked by spring force and unlocked by energising the solenoid (Fig. 6). Solenoid interlocks with power to lock are locked by energising the solenoid and unlocked by spring force (Fig. 7). Both principles are common on machine safety guards. For the protection of personnel against hazardous stored energy (e.g. run-on), the use of solenoid interlocks with spring to lock is strongly recommended. Solenoid interlocks with power to lock may only be used in special cases after evaluating fully all the hazards, since in case of power failure or machine power switch off, the guard can be opened immediately and the operator exposed to the hazard. On the other hand, solenoid interlocks with power to lock are suitable for machine and/or process safety. This type of solenoid interlock can deter the operator from interrupting a running process and, for example, avoiding damage to machine tools. The power to lock principle enables fast access into the machine in case of failure when the machine power is switched off the safety guard can be unlocked. Using a solenoid interlock in this way can help optimise the machine productivity. Fig. 6: Spring to lock Fig. 7: Power to lock 8

oid interlock Mounting sets simplify fitted Schmersal has developed mounting sets to enable quick and safe fitting of solenoid interlocks and actuators. The mounting sets are suitable for fitting on common steel and aluminium profile systems and simplify the alignment between actuator and solenoid interlock (Fig. 8). The unique housing design of the AZM 190 allows a particularly elegant solution for hinged guards and aluminium profile systems. The angled actuating head allows the solenoid interlock to be mounted inside the hazardous area so that only the head is visible from outside. In addition to the practical advantages, this device can also improve the optical impression of the machine an important factor on modern machines (Fig. 9). Caution: Pre-tensioned safety guards! In spite of careful safety guard design, the practice shows that they often become deformed, distorted or misaligned during their lifetime. With this in mind, a certain play between the actuator and the solenoid interlock is tolerated by design, so that the safety guard can be displaced from its ideal position. Safety guards are also pretensioned by operators trying to open a locked door. This force must not exceed a specific maximum pretension force for the solenoid interlock concerned, otherwise the solenoid will not be able to unlock, and the door cannot be opened. Schmersal s patented toggle-lever system can withstand a maximum admissible pre-tension of up to 500 N (AZM 415). In addition, a specific holding force (the so-called latching force) is present, so that the tensioned guard is held closed even in an unlocked condition. When selecting the appropriate solenoid interlock, the maximum permissible holding force on the device in the locked position must be taken into account. Schmersal solenoid interlocks are available with a holding force of between 1000 N and 3500 N. Fig. 8: Mounting kits simplify the fitting of solenoid interlocks Fig. 9: Simple but effective mounting of the AZM 190 due to its special housing design 9

Installation and operating solenoid interlocks During op Since solenoid interlocks are either locked or unlocked by a solenoid, they require differing solutions for manual unlocking in a power-off condition (for example during installation or maintenance) than for unlocking during machine operation. Manual release Machinery fitted with spring to lock solenoid interlocks normally have a way of opening the safety guard during a power failure, usually by means of a tool such as a triangular key (Fig. 10). The Schmersal solenoid interlocks are fitted with such an auxiliary unlocking mechanism, the so-called manual release. Upon operating the manual release, the positive break safety contacts are simultaneously opened thus preventing unexpected machine restart. Battery-operated release* When spring to lock solenoid interlocks are installed in inaccessible or concealed positions, and in the case of power off or failure, the operator is confronted with the problem of how he gains access to the machine. In this case, it is useful to provide a separate power supply for the solenoid. This can be a battery-operated release in the control cabinet. The battery is charged during normal operation and in the case of power failure, can be switched on to unlock the safety guard. * In preparation Fig. 10: Manual release Fig. 11: B30 actuator with integrated emergency handle 10

eration Emergency exit The emergency exit allows an intentional opening of the safety guard from inside the machine without tools, for example when personnel are trapped inside a machine (Fig. 12 and 13). For this application, the Schmersal Group has developed the AZM 415 and TZFS.NN with emergency release which, used together with a B30 actuator and integrated emergency handle, allow an emergency exit from inside a machine guard (Fig. 11). Emergency release With an emergency release, the safety guard can be opened from outside the hazardous area without the operator using any tool, for example when a fast intervention into the hazardous area is required to guarantee process safety. Unlocking is possible without special tools, resetting however requires a repair-like intervention. Standstill monitoring Solenoid interlocks for personnel protection are used when the time taken to access the hazardous area from the safety guard can be less than the time needed for the hazard to have ceased (i.e. the moving parts have come to a standstill). The safety guard must remain locked until the machine hazard has been reduced to a minimum. In this case, the solenoid interlock can be combined with a fail-safe standstill monitor or in case of constant run-down times fail-safe delay timers. For these applications, the Schmersal Group has developed a comprehensive range of fail-safe standstill monitors (Fig. 14). For these types of machine an emergency stop safety control module with delay on de-energisation (stop category 1 to EN 60204-1) must not be used, since the failure mode of the delay function is t = 0. This would result in the safety guard unlocking too soon in case of failure. Fig. 12: Emergency exit Fig. 13: Emergency exit or emergency release Fig. 14: Solenoid interlock with integrated fail-safe standstill monitor 11

Installation and operating solenoid interlocks Full body Hazardous areas of machinery and plant can be so large, that the machine can be entered completely by personnel. The Machinery Directive requires that in this case personnel cannot be inadvertently locked into the hazardous area. To prevent this situation, solenoid interlocks can be fitted with the emergency exit system described previously. This allows personnel to evacuate the hazardous area easily. By operating the emergency release, the safety circuit of the machine is interrupted and the machine is shut down. However, in order not to endanger personnel that could be inside the hazardous area during the start-up or restart, the following aspects have to be taken into account. Fig. 14: AZM 415 with B30 actuator Fig. 15: Full body access of hazardous areas 12

access First of all, the start button must be installed in a location where the operator has a complete overview of the hazardous area. In addition the start button must not be accessible from inside the hazardous area. Secondly it is strongly recommended to use a safety control module with a monitored start circuit. These safety control modules enable only a trailing edge signal from the start button, i.e. they enable when the button is released, not when it is pressed. The trailing edge control module can thus detect a failure in the start button (e.g. contact welding) and manipulation (button held down). The comprehensive range of safety control modules from the Schmersal Group include monitored start (trailing edge) function. 13

Typical applications On machine tools Typical mounting positions for solenoid interlocks on machine tools On guard fencing systems Installation of a solenoid interlock AZM 190 with emergency exit from inside the hazardous area Installation of a solenoid interlock AZM 161 on a sliding guard 14 Installation of a solenoid interlock AZM 161 with emergency exit from inside the hazardous area Installation of a solenoid interlock AZM 415 with emergency exit from inside the hazardous area

Selection table: Solenoid interlocks AZM 170 AZM 161 TZF/TZM AZM 190 AZM 415 Size in mm (B x H x D) 90 x 84 x 30 130 x 90 x 30 129 x 92 x 41 89 x 178 x 41 130 x 100 x 46,5 Application Max. holding force Actuator alignment tolerance Max. actuator play (in locked condition) Min. radius for hinged guards Number of actuating directions 1000 N2000 N1700 N2000 N3500 N 2500 N* ± 2 mm ± 2 mm ± 4 mm ± 4 mm ± 3 mm 4 mm 5 mm 11 mm 5 mm 3 mm 50 mm 95 mm 150 mm 150 mm 250 mm 2 3 3 ** 4 1 Contacts Solenoid: 1NC Solenoid: 1NO/1NC or 1NO/2NC Solenoid: 1NC or 1NO/1NC Solenoid: 1NO/1NC or 2NC Solenoid: 1NO/1NC Latching force Actuator: 2NC or 1NO/1NC Actuator: 1NO/3NC, 2NO/2NC or 1NO/2NC Actuator: 2NC or 1NO/1NC Actuator: 1NC or 1NO Actuator: 1NO/1NC 30 N30 N30 N30 Nbis 500 N Approvals BG, UL, CSA BG, UL, CSA BG, UL, CSA BG, UL, CSA BG, UL, CSA Mounting set Yes Yes Yes *** Yes Yes *** Material Thermoplastic Thermoplastic Thermoplastic Thermoplastic Metal alloy Page 16 17 18 19 20 * = Only in conjunction with reinforcing bracket TZ-44 ** = 4 upon request *** = Only in conjunction with B30 actuator 15

28 Solenoid interlocks AZM 170 Actuators Accessories 30 22 Rmin. 200 4,5 4,3 Rmin.140 33 2 23 Straight actuator B1 Mounting set 31 23 90 22 60 8 18 30 ø4,2 Rmin. 200 Rmin.140 ø4,2 15 24 36 30 13 8 30 23 Straight actuator, rubber mounting B1-2245 Connector plug M 12 x 1 (with cable) Characteristics Enclosure: glass-fibre reinforced thermoplastic, self extinguishing Protection class: IP 67 Termination: cut clamp terminals (IDC) Cable size: 0.75 1.0 mm 2, flexible U i : 250 V I th : 10 A Utilisation category: AC-15; DC-13 I e /U e : 4 A / 230 VAC 4 A / 24 VDC Power consumption: max 10 W Solenoid duty rating: 100% ED U s : 24 VAC/DC 110 VAC, 50/60 Hz 230 VAC, 50/60 Hz Mechanical life: > 1 million operations Holding force F max : 1000 N 12 6 36 2 7,5 Angled actuator B5 32 4,3 11 30 22 23 30 22 24 4 4,3 7 Rmin. 200 Rmin.140 Rmin.50 Rmin.50 Connector plug M 12 x 1 23 Flexible actuator B6 Triangular key M5 Standards IEC/EN 60947-5-1; EN 1088; BG-GS-ET-19 Approvals H C D Ordering details AZM 170➀-➁zrk➂-➃-➄ No. Replace Description ➀ IDC terminals SK Screw terminals ➁ 11 1NO/1NC 02 2NC ➂ Spring to lock a Power to lock ➃ Cable gland ST Connector M 12 x 1 ➄ 24 VAC/DC U s 24 VAC/DC 110 VAC U s 110 VAC 230 VAC U s 230 VAC 16 Ordering details Straight actuator: AZ 17/170-B1 Rubber mounting: AZ 17/170-B1-2245 Angled actuator: AZ 17/170-B5 Flexible actuator: AZM 170-B6 Ordering details Mounting set: MS AZM 170 Connector plug M 12 x 1, 5 m cable length: A-coded: 5121508000 B-coded: 5121519000 without cable: A-coded: 5080371000 B-coded: 5121494000 Triangular key M5: 5022575000 * per solenoid interlock 1 x A-coded 1 x B-coded

Solenoid interlocks AZM 161 Actuators Accessories 8 ø5,5 Rmin.150 16 5 16 40 56 8 Rmin.180 14 56 Rmin.150 8 18 72 6 6 90 6 30 32,7 5 32,7 2 Straight actuator B1 27 Mounting set ø5,5 Rmin.180 30 2 27 8 130 Straight actuator B1E Connector plug M 12 x 1 (with cable) Characteristics Enclosure: glass-fibre reinforced thermoplastic, self extinguishing Protection class: IP 67 Termination: screw terminals or cage clamps U i : 250 V I th : 10 A Utilisation category: AC-15; DC-13 I e /U e : 4 A / 230 VAC 2.5 A / 24 VDC Power consumption: max 10 W Solenoid duty rating: 100% ED U s : 24 VAC/DC 110 VAC, 50/60Hz 230 VAC, 50/60 Hz Mechanical life: > 1 million operations Holding force F max : 2000 N ø5,5 11 Flexible actuator B6 40 39 16 Rmin.95 Rmin.95 Slot sealing plug Release types Standards IEC/EN 60947-5-1; EN 1088; BG-GS-ET-19 Approvals H C D Ordering details AZM 161 ➀-➁rk➂➃-M16-➄ No. Replace Description ➀ SK Screw terminals CC Cage clamp ➁ 12/12 2NO/4NC 242NO/4NC 33 3NO/3NC ➂ Spring to lock a Power to lock ➃ Manual release T Emergency exit N Emergency release ➄ 024U s 24 VAC/DC 110 U s 110 VAC 230 U s 230 VAC Ordering details Straight actuator: AZM 161-B1 Straight actuator: AZM 161-B1E Flexible actuator: AZM 161-B6 * per solenoid interlock 1 x A-coded 1 x B-coded Ordering details Mounting set: MS AZM 161 Connector plug M 12 x 1, 5 m cable length: A-coded: 5121508000 B-coded: 5121519000 without cable: A-coded: 5080371000 B-coded: 5121494000 Slot sealing plug (3 pieces): 3025755000 Manual release Emergency exit Emergency release Triangular key M5: 5022575000 17

21 13 4,2 Solenoid interlocks TZM / TZF Actuators Accessories 27 8 Rmin. 650 15 80 33 20 3 4,2 8 32 Rmin. 250 Straight actuator TZ/CO Reinforcing bracket TZ-44 22 92 20 Rmin. 650 20 32 15 95 65,5 20,5 Rmin. 250 129 125 65 79 22 14,5 41 Angled actuator TZ/CW 8 3 Angled triangular key TZ-75 Characteristics Enclosure: glass-fibre reinforced thermoplastic Protection class: IP 67 Termination: screw terminals Cable size: max. 2,5 mm 2 U i : 250 V I th : 10 A Utilisation category : AC-15; DC-13 I e /U e : 8 A / 250 VAC 5 A / 24 VDC Power consumption : max. 7 W Solenoid duty rating : 100% ED U s : 24 VDC 115 VAC, 50/60 Hz 230 VAC, 50/60 Hz Mechanical life : 2 million operations Holding force F max. : 1700 N 2500 N in conjunction with TZ-44 14 36 4 35 99 15 60 48-44 18 7 23 4,2 20 32 3 6 20 6,3 30 40 Flexible actuator TZ/COF/HIS.2 Rmin. 350 Rmin.150 Rmin. 650 Rmin.175 8 Standards IEC/EN 60947-5-1; EN 1088; BG-GS-ET-19 Shortened actuator TZ/CK Approvals H C D Ordering details * TZ➀➁➂➃ No. Replace Description ➀ M Power to lock F Spring to lock ➁ 11-12, 21-22 in series W 11-12, 21-22 individually C 11-12, 21-22 in series + Solenoid: 1S ➂ Without manual release S With manual release S.NN With em. + man. release ➃ U s 24 VDC 115 U s 115 VAC 230 U s 230 VAC 18 Ordering details Straight actuator rubber mounting (included in delivery): TZ/CO Angled actuator: TZ/CW Flexible actuator rubber mounting: TZ/COF/HIS.2 Shortened actuator rubber mounting: TZ/CK Notice: Actuator head can be repositioned * available from Elan Schaltelemente GmbH & Co. KG Ordering details Reinforcing bracket:: Angled triangular key: TZ-44 TZ-75

3 Solenoid interlocks AZM 190 Actuators Accessories 52 6,5 Rmin. 650 48 6,5 Rmin. 350 13,5 20 30 Rmin.175 60 38 89 76 32 35 15 6 13,5 53,5 5,3 Rmin. 650 Rmin. 250 6 116 178 29,5 22,5 41 6 7,5 57,5 8,5 16,5 32 25 48 6,5 48 6,5 48 Rmin.175 38 40 3 11 8 32 25 Rmin. 275 8,5 57,5 16,5 ø4,3 Straight actuator B1 13,5 Flexible actuator B3/2x15 13 30 45 Actuator with front mounting B5 Mounting set Characteristics Enclosure: glass-fibre reinforced thermoplastic Protection class: IP 67 Termination: screw terminals Cable size: max 1.5 mm 2 Cable entry: 2 x M 20 U i : 400 V I th : 10 A Utilisation category: AC-15; DC-13 I e /U e : 8 A / 230 VAC 5 A / 24 VDC Power consumption: max 8.5 W Solenoid duty rating: 100% ED U s : 24 VDC 110 VAC, 50/60 Hz 230 VAC, 50/60 Hz Mechanical life: 2 million operations Holding force F max : 2000 N 25 57,5 32 8,5 Flexible actuator B3/15 60 38 16,5 13,5 Rmin. 250 Rmin.150 Triangular key M3 13,5 Standards IEC/EN 60947-5-1; EN 1088; BG-GS-ET-19 Flexible actuator B3/7,5 Axial cable entry ZPG 190 Approvals H C D Ordering details AZM 190-➀rk➁-➂ No. Replace Description ➀ 11/01 Solenoid: 1NO/1NC, Actuators: 1NC 02/10 Solenoid: 2NC, Actuators: 1NO 11/10 Solenoid: 1NO/1NC, Actuators: 1NO ➁ Spring to lock a Power to lock ➂ 24 VDC U s 24 VDC 110 VAC U s 110 VAC 230 VAC U s 230 VAC Ordering details Straight actuator: AZM 190-B1 With front mounting: AZM 190-B5 Flexible actuator: AZM 190-B3/15 Flexible actuator: AZM 190-B3/7,5 Notice: Actuator head can be repositioned Ordering details Flexible actuator: AZM 190-B3/2x15 Mounting set: MP 190 Triangular key M3: M3-a Axial cable entry: ZPG 190 19

Solenoid interlocks AZM 415 Actuators Accessories 55 0-6 56 20 7 19 30 22 6,5 15 35 Straight actuator B1 Mounting set Rmin. 250 29,5 28 28 52 66 6,4 12 11 6,5 30 24,7 100 84 14 8,6 46,5 114 130 7 20 Flexible actuator B2 91 Characteristics Enclosure: light-alloy diecast, paint finish Protection class: IP 67 Termination: screw terminals Cable size: max 2.5 mm 2 Cable entry: 2 x M 20 (Pg on request) U i : 250 V I th : 6 A Utilisation category: AC-15 I e /U e : 4 A / 230 VAC Power consumption: max 10 W Solenoid duty rating: 100% ED U s : 24 VAC/DC 110 VAC, 50/60 Hz 230 VAC, 50/60 Hz Mechanical life: > 1 million operations Holding force F max : 3500 N 20 55 68 28 14 7 M6 20 Flexible actuator B3 117 157 52 66 30 6,4 12 91 74 90 105 Rmin. 250 157 Standards IEC/EN 60947-5-1; EN 1088; BG-GS-ET-19 Actuator B30 Approvals H C D Ordering details AZM 415 -➀zpk➁➂-➃ No. Replace Description ➀ 22 2NO/2NC ➁ Spring to lock a Power to lock ➂ Without manual release E Manual release: triangular key T Emergency release: latching push-button ➃ M20 Cable entry M20 ➄ 24 VAC/DC U s 24 VAC/DC 110 VAC U s 110 VAC 230 VAC U s 230 VAC 20 Ordering details Straight actuator: AZ/AZM 415-B1 Flexible actuator: AZ/AZM 415-B2 Flexible actuator: AZ/AZM 415-B3 Actuator B30: see page 11 Ordering details Mounting set: see page 11

Selection table: Actuators B30 and mounting sets Actuator with emergency handle B30 TZF/TZM AZM 161 AZM 415 AZM TZF/TZM - B30-01 AZM 161 - B30-01 AZ/AZM 415 - B30-01 Hinge R / switch inside AZM TZF/TZM - B30-02 AZM 161 - B30-02 AZ/AZM 415 - B30-02 Hinge L / switch inside TZF/TZM - B30-05 AZM 161 - B30-05 AZ/AZM 415 - B30-05 AZM (only power to lock) (only power to lock) (only power to lock) Hinge R / switch outside TZF/TZM - B30-06 AZM 161 - B30-06 AZ/AZM 415 - B30-06 AZM (only power to lock) (only power to lock) (only power to lock) Hinge L / switch outside 1 x MP TZF/TZM 1 x MP TZF/TZM - B30 2 x MP AZ/AZM 415 - B30 Parallel mounting 1 x MP AZM 161-01 2 x MP AZ/AZM 415 - B30 1 x MP AZM 415-22 2 x MP AZ/AZM 415 - B30 Mounting set Adjacent mounting 1 x MP AZM 161-02 2 x MP AZ/AZM 415 - B30 Actuator without emergency handle B30 TZF/TZM AZM 161 AZM 415 AZM TZF/TZM - B30-03 AZM 161 - B30-03 AZ/AZM 415 - B30-03 Hinge R / switch inside AZM TZF/TZM - B30-04 AZM 161 - B30-04 AZ/AZM 415 - B30-04 Hinge L / switch inside TZF/TZM - B30-07 AZM 161 - B30-07 AZ/AZM 415 - B30-07 AZM Hinge R / switch outside TZF/TZM - B30-08 AZM 161 - B30-08 AZ/AZM 415 - B30-08 AZM Hinge L / switch outside 1 x MP TZF/TZM 1 x MP TZF/TZM - B30 1 x MP AZ/AZM 415 - B30 Parallel mounting 1 x MP AZM 161-01 1 x MP AZ/AZM 415 - B30 1 x MP AZM 415-22 1 x MP AZ/AZM 415 - B30 Mounting set Adjacent mounting 1 x MP AZM 161-02 1 x MP AZ/AZM 415 - B30 A detailed product description can be found in the brochure Safety Guard Door Systems STS 21

Door-handle switches TG-W GR 1Öx TG-W GR 2Öx TG-S GR 2ÖSR 4 4 10 M12x 1 60 80 10 M12x 1 60 80 10 60 80 30 150 8,5 30 150 8,5 8,5 175 30 14 Ø28 30 48 Ø28 30 48 Ø28 30 48 200 200 225 Characteristics Release button: 1 change-over contact Emergency Stop button: 1 NC contact Push button: no U e : 24 VDC ± 15% Contact load capacity: max 30 VAC, 36 VDC, max 1.5 A (cos = 1) Termination: connector M 12 x 1, 8-pole Status indicator: 2 LED Protection class: IP 65 with connector Enclosure: PA + POM Characteristics Release button: 1 change-over contact Emergency Stop button: 2 NC contacts Push button: no U e : 24 VDC ± 15% Contact load capacity: max 30 VAC, 36 VDC, max 1.5 A (cos = 1) Termination: connector M 23 x 1, 12-pole Status indicator: 2 LED Protection class: IP 65 with connector Enclosure: PA + POM Characteristics Release button: 1 NO contact Emergency Stop button: 2 NC contacts Push button: 1 NO contact U e : 24 VDC ± 15% Contact load capacity: max 30 VAC, 36 VDC, max 1.5 A (cos = 1) Termination: connector M 23 x 1, 12-pole Status indicator: 3 LED Protection class: IP 65 with connector Enclosure: PA + POM Standards IEC/EN 60947-5-1, IEC/EN 60947-5-5, DIN VDE 0660-200, EN 418 Standards IEC/EN 60947-5-1, IEC/EN 60947-5-5, DIN VDE 0660-200, EN 418 Standards IEC/EN 60947-5-1, IEC/EN 60947-5-5, DIN VDE 0660-200, EN 418 Approvals H under preparation Approvals H under preparation Approvals H under preparation Ordering details Ordering details Ordering details TG-W GR 1Öx TG-W GR 2Öx TG-S GR 2ÖSR 22

Door-handle switches Accessories Connector plug M 12 x 1, 8-pole Connector plug M 23 x 1, 12 pole Ordering details Connector plug M 12 x 1, 8-pole, with 5 m cable length: 01362195 Connector plug M 23 x 1, 12-pole, without cable: 01362200 23

Safety control modules - Multi-function SRB 308IT SRB 219IT SRB 301LC A1 A1.1 F2 S12 S11 S21 S22 X1 X2 X3 X4 X5 X6 13 23 33 K1 41 53 A1 A1.1 F2 S12 S11 S21 S22 X1 X2 X3 X4 X5 X6 RT K1 13 23 41 37 A1 S12 S11 S21 S22 X1 X2 13 23 33 41 AC/ DC A2 F1 UB Ui K1 K2 K4 K3 S31 S32 Y1 Y2 Y3 Y4 Y5 K2 K3 Y6 14 24 34 42 54 AC/ DC A2 F1 UB Ui K1 K2 K4 K3 K5 S31 S32 Y1 Y2 Y3 Y4 Y5 Y6 K2 K3 Y7 14 24 42 K4 K5 Y8 38 AC/ DC A2 F1 K1 UB Ui K2 K1 K2 14 24 34 42 Characteristics U e : 24 VDC 15%/+20%, 24 VAC, 48 VAC, 115 VAC, 230 VAC I e : 0.1 A (DC version) Start conditions: start, reset button, autostart Feedback circuit: yes Stop category: 0 Control category: 4 Monitored inputs 1 or 2 channels Enabling contacts: 3 enabling paths Contact load capacity: max 250 VAC, max 6 A (cos = 1) Signalling output: 8 transistor outputs total 100 ma, short-circuit proof Termination: plug-in screw terminals Cable size: max 2.5 mm 2 Status indicator: 5 LED Dimensions: 45 x 100 x 121 mm Characteristics U e : 24 VDC 15%/+20%, 24 VAC 15%/+10% I e : max 0.19 A (DC version) Start conditions: start, reset button, autostart Feedback circuit: yes Stop category: 2 x "Stop 0", 1 x "Stop 1" Control category: 4 Monitored inputs 1 or 2 channels Enabling contacts: 2 enabling paths, 1 enabling path 1 30 s delayed Contact load capacity: max 250 VAC, max 6 A (cos = 1) Signalling output: 1 NC, potential-free, 8 transistor outputs total 100 ma, short-circuit proof Termination: plug-in screw terminals Cable size: max 2.5 mm 2 Status indicator: 7 LED Dimensions: 45 x 100 x 121 mm Characteristics U e : 24 VAC - 15%/ + 10% residual ripple max. 10% 24 VDC - 15%/ + 20% I e : max. 0,08 A Start conditions reset button, autostart Feedback circuit: yes Stop category 3 x Stop 0 Control category: 4 Monitored inputs 1 or 2 channels Enabling contacts: 3 enabling paths Signalling output: 1 NC contact Termination: screw terminals Cable size: max 2.5 mm 2 Status indicator: 4 LED Dimensions: 22.5 x 100 x 121 mm Standards IEC/EN 60204-1; BG-GS-ET-20 Standards IEC/EN 60204-1; BG-GS-ET-20 Standards IEC/EN 60204-1; EN 954-1; BG-GS-ET-20 Approvals H C D under preparation Ordering details SRB 308 IT- ➀ No. Replace Description Approvals H C D under preparation Ordering details SRB 219 IT- ➀ No. Replace Description Approvals H C D Ordering details SRB 301 LC ➀ No. Replace Description ➀ 24 V 24 VAC/DC 48 V 48 VAC 115 V 115 VAC 230 V 230 VAC ➀ 24 V 24 VAC/DC ➀ 24 VAC/DC 24

Safety control modules SRB 301ST SRB 211ST SRB 206 A1 S12 S11 S21 S22 X2 13 23 33 41 A1 S12 S11 S21 S22 X1 X2 13 23 37 A1 X1 S11 S12 S22 S71 S72 S82 S92 S102 S112 S122 X3 X2 S31 S32 S42 S51 S52 S62 13 23 AC/ DC A2 F1 K1 UB Ui K2 K1 K2 14 24 34 42 AC/ DC A2 F1 K1 UB Ui K2 K1 K2 K3 K4 14 K3 K4 24 38 Y1 F1 UB Ui A2 K1 K2 A1.1 Y1 Y2 Y3 Y4 Y5 Y6 K1 K2 14 24 Characteristics U e : 24 VDC - 15%/ + 20% residual ripple max. 10% I e : 0.16 A Start conditions reset button, (trailing edge) autostart Feedback circuit: yes Stop category 3 x Stop 0 Control category: 4 Monitored inputs 1 or 2 channels Enabling contacts: 3 enabling paths Drop-out delay: 20 ms Signalling output: 1 NC contact Termination: plug-in screw terminals Cable size: max 2.5 mm 2 Status indicator: 4 LED Dimensions: 22.5 x 100 x 121 mm Characteristics U e : 24 VAC - 15%/ + 10% residual ripple max. 10% 24 VDC - 15%/ + 20% I e : 0.24 A Start conditions reset button, (trailing edge) autostart Feedback circuit: yes Stop category 2 x Stop 0, 1 x Stop 1 (1...30 s delayed) Control category: 4 Monitored inputs 1 or 2 channels Enabling contacts: 3 enabling paths Signalling output: Termination: plug-in screw terminals Cable size: max 2.5 mm 2 Status indicator: 5 LED Dimensions: 22.5 x 100 x 121 mm Characteristics U e : 24 VAC - 15%/ + 10% residual ripple max. 10% 24 VDC - 15%/ + 20% I e : max. 0,125 A (DC Version) Start conditions reset button, (trailing edge) autostart Feedback circuit: yes Stop category 2 x Stop 0 Control category: 4 Monitored inputs 6 x 2 channels (NC/NC) Enabling contacts: 2 enabling paths Drop-out delay: 30 ms Signalling output: Termination: screw terminals Cable size: max 2.5 mm 2 Status indicator: 4 LED Dimensions: 45 x 100 x 121 mm Standards IEC/EN 60204-1; EN 954-1; BG-GS-ET-20 Standards IEC/EN 60204-1; EN 954-1; BG-GS-ET-20 Standards IEC/EN 60204-1; EN 954-1; BG-GS-ET-20 Approvals H C D Ordering details SRB 301 ST ➀➁ No. Replace Description Approvals H C D Ordering details SRB 211 ST ➀➁ No. Replace Description Approvals H C Ordering details under preparation SRB 206 ➀➁ No. Replace Description ➀ 24 VAC/DC ➀ 24 VAC/DC ➀ ST without cross-wire monitoring SQ with cross-wire monitoring ➁ 24 VAC/DC 230V 48... 230VAC 25

Fail-safe standstill monitors FWS 1205 FWS 1206 FWS 2316C A1 A1 X1 X2 13 23 A1 A1 X1 X2 13 23 A1 Y1 Y2 X1 13 23 33 max. 100mA K1 K2 max. 100mA K1 K2 max. 100mA K1 K2 A2 A2 Y1 Y2 X3 14 24 A2 A2 Y1 Y2 X3 X4 14 24 A2 X2 X3 X4 X5 14 24 34 Characteristics U e : 24 VDC ± 15% I e : 0.2 A Control category: 3 Monitored inputs: 2 channels, pulse generator p-type Start conditions Automatic Enabling contacts: 2 enabling path Contact load capacity: max 250 VAC, max 6 A (cos = 1) Signalling output: 2 transistor outputs, Y1 + Y2 = max 100 ma, p-type, short-circuit proof Termination: screw terminals Cable size: max 2.5 mm 2 Status indicator: LED (ISD) Dimensions: 22.5 x 100 x 121 mm Characteristics U e : 24 VDC ± 15% I e : 0.2 A Control category: 3 Monitored inputs 1 or 2 channels, pulse generator p-type Start conditions Automatic Enabling contacts: 2 enabling path Contact load capacity: max 250 VAC, max 6 A (cos = 1) Signalling output: 2 transistor outputs, Y1 + Y2 = max 100 ma, p-type, short-circuit proof Termination: screw terminals Cable size: max 2.5 mm 2 Status indicator: LED (ISD) Dimensions: 22.5 x 100 x 121 mm Characteristics U e : 24 VDC ± 15 % 110 VAC 230 VAC I e : 0.3 A (DC version) Feedback circuit: yes Control category: 3 Monitored inputs 2 channels, pulse generator p-type Start conditions Reset button Enabling contacts: 3 enabling paths Contact load capacity: max 250 VAC, max 6 A (cos = 1) Signalling output: 2 transistor outputs, Y1 + Y2 = max 100 ma, p-type, short-circuit proof Termination: screw terminals Cable size: max 4 mm 2 Status indicator: LED (ISD) Dimensions: 55 x 75 x 110 mm Standards IEC/EN 60204-1; EN 954-1; BG-GS-ET-20 Standards IEC/EN 60204-1; EN 954-1; BG-GS-ET-20 Standards IEC/EN 60204-1; EN 954-1; BG-GS-ET-20 Approvals H C D under preparation Ordering details FWS 1205 ➀ No. Replace Description Approvals H C D under preparation Ordering details FWS 1206 ➀ No. Replace Description Approvals C D Ordering details FWS 2316. ➀C No. Replace Description ➀ A B C Standstill frequencies Inputs X1/X2: 1 Hz/2 Hz 2 Hz/2 Hz 1 Hz/1 Hz ➀ A C Standstill frequencies Inputs X1/X2: 1 Hz/2 Hz 1 Hz/1 Hz ➀ 24 VDC 1 110 VAC 2 230 VAC 26

Fail-safe standstill monitors / Delay timers AZR 31 S1 EBW AZS 2305 A1 L1 L2 L3 41 13 23 33 A1 24V IN 0V TG A1 Y1 Y2 13 23 33 S1 S1,S2 S2 K1 max. 100mA K1 K2 A2 PE X1 X2 42 14 24 34 K1 A2 13 14 21 22 A2 S13 K2 S14 S21 S22 14 24 34 Characteristics U e : 24 VDC 24 VAC 110 VAC ± 15 % 230 VAC ± 15 % 0.13 A (DC version) yes I e : Feedback circuit: Control category: 4 Monitored inputs L1, L2, L3: 400 VAC Enabling contacts: 3 enabling paths Contact load capacity: max 400 VAC, max 6.2 A (cos = 1) Signalling output: 1 NC Termination: screw terminals Cable size: max 2.5 mm 2 Status indicator: 5 LED Dimensions: 45 x 73.2 x 121 mm Characteristics U e : 24 VDC ± 10% I e : 0,09 A Frequency: 0,08 Hz... 100 khz Control category: B Monitored inputs: 1 pulse generator Enabling contacts: 1 enabling path Contact load capacity: max. 240VAC, max. 3A (cos = 1) 24 VDC, max. 2A (cos =1) Signalling output: 1NC, positive break Termination: screw terminals Cable size: max. 2x 2,5 mm 2 Status indicator: LED Dimensions: 45 x 83 x 126,5 mm Characteristics U e : 24 VDC ± 15 % 110 VAC 230 VAC I e : 0.1 A at 24 VDC Time setting: 0.1 s 99 min Control category: 3 Monitored inputs 1 NC / 1 NO Enabling contacts: 3 enabling paths Contact load capacity: max 250 VAC, max 6 A (cos = 1) Signalling output: 2 transistor outputs, Y1 + Y2 = max 100 ma, p-type, short-circuit proof Termination: screw terminals Cable size: max 4 mm 2 Status indicator: LED (ISD) Dimensions: 55 x 75 x 110 mm Standards IEC/EN 60204-1; EN 954-1; BG-GS-ET-20 Standards IEC/EN 60204-1; EN 954-1; BG-GS-ET-20 Standards IEC/EN 60204-1; EN 954-1; BG-GS-ET-20 Approvals H Ordering details AZR 31 S1 ➀ No. Replace Description Approvals Ordering details * EBW- ➀ No. Replace Description Approvals H C D Ordering details AZS 2305. ➀ No. Replace Description ➀ 24 VDC 24 VDC 24 VAC 24 VAC 110 VAC 110 VAC 230 VAC 230 VAC ➀ WB Factory defaults AZ Customer-specific settings ➀ 24 VDC 1 110 VAC 2 230 VAC * available from Elan Schaltelemente GmbH & Co. KG 27

Wiring examples General notes The following wiring diagrams are very practice-oriented, and outline only a few examples of how solenoid interlocks can be integrated into the machine safety control system for various applications. In order to obtain the indicated control categories to EN 954-1, the following points should be observed: 1. The specific safety regulations contained in the prevailing C-standards describe how solenoid interlocks should be integrated into the safety circuit of a machine. If the manufacturer fulfils these requirements, he simultaneously complies with the relevant essential requirements of the Machinery Directive by reason of the so-called presumption of conformity. The manufacturer may deviate from the C-standard, but in that case, he must show that his machine is designed in such a way that through equivalent measures, it conforms to the essential safety requirements laid down in the Directive. If no C-standard is available for the specific application, the B-standards must be consulted for information regarding the use of solenoid interlocks. 2. Second safety guard switch: The second safety guard switch can serve for fault recognition and fault control if the solenoid interlock incurs a critical failure, such as undetectable damage to the internal or external mechanism. The installation of a second safety guard switch can be omitted: In case of thorough and proper safety guard design, i.e. a stable door mechanism with solid end stops, designed to operate correctly throughout the planned lifetime of the machine, If the maximum admissible holding force and other mechanical limits of the solenoid interlock are observed, If the actuator is inextricably attached to the safety guard (see page 7), preferably in a concealed position, If the actuator blade is manufactured in one piece and not made of plastic or die-cast material, If the solenoid interlock contains a fail-safe locking mechanism. 3. For applications where the higher safety requirements must be met, the following should be observed: for applications in control category 4, the possible accumulation of faults must also be considered. To detect multiple faults all safety guards fitted with electromechanical devices must also be equipped with a start-up test. i.e. where solenoid interlocks are used, the safety guard must be opened and closed after powering up the machine. This ensures the detection of hidden faults that were erased due to the supply voltage being switched off. for applications in control category 3 some faults are not always continuously recognised if the solenoid interlocks are connected in series. An accumulation of faults in one solenoid interlock could in this case lead to the loss of the safety function for a particular safety guard. For example, the recognition of a fault in a solenoid interlock circuit caused by short-circuit or cable breakage can be cancelled out by actuating another solenoid interlock. This fact must be considered in the risk analysis. if the possibility of short-circuit or cross-wire faults cannot be excluded by special cable routing, the use of safety control modules with cross-wire detection is recommended. The ultimate classification of a safety control circuit in a control category to EN 954-1 can only be defined for a specific application once all aspects of the system have been evaluated. For this reason, the control categories proposed in the following wiring diagrams apply solely to the input circuit and do not consider the safety control module or any other part of the safety control circuit. However, we always recommend the use of a second safety guard switch: for applications to control category 4 to EN 954-1, for non-visible hazards such as radiation, electric shock, etc. 28

S14 14 24 A1 Y1 Y2 X1 13 23 33 MadeinGermany Wuppertal A2 S13 S14 S21 S22 14 24 34 S14 14 24 Selection table: wiring diagrams Selection criteria AZM 170 AZM 161 TZF/TZM AZM 190 AZM 415 Principle Number of guards Number of unlock buttons Number of switches per guard 1 1 1 1.1 1.2 1.3 1.2 1.3 1.2 2 1.4 1.4 1.4 1.4 1.4 Spring to lock >1 1 1 3.1 3.2 3.3 3.2 3.3 3.2 >1 1 2.1 2.2 2.3 2.2 2.3 2.2 1 1 1 4.1 4.2 4.3 4.2 4.3 4.2 Power to lock 2 4.4 4.4 4.4 4.4 4.4 >1 1 1 5.1 5.2 5.3 5.2 5.3 5.2 Selection criteria FWS 1205 FWS 1206 FWS 2316C AZR 31 S1 EBW Input Number pulse generators Standstill signal A1+ A2-13 Y1 AES 1235 23 X1 A1+ A2-13 Y1 AES 1235 23 X1 A1 Y1 Y2 X1 13 23 33 MadeinGermany Wuppertal ON A1 S13 X1 51 41 13 23 33 ON A1 S13 X1 51 41 13 23 33 S13 S21 S22 S13 S21 S22 Funktion S1 A2 S13 S14 S21 S22 14 24 34 OUT A2 S14 X2 52 42 14 24 34 OUT A2 S14 X2 52 42 14 24 34 Yes 6.1 1 No 6.2 6.4 Pulse generator Yes 6.1 2 No 6.2 6.3 e.m.f. monitoring 6.5 Selection criteria AZS 2305 Funktion S1 Fail-safe delay timer 7.1 29

Wiring diagram No. 1.1 Spring to lock solenoid Fail-safe standstill monitor Fail-safe delay timer S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of one safety guard Monitoring of hazardous run-on motion Solenoid interlocks: AZM 170-02zrk Safety circuit: 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: After unlocking, the safety guard must be opened and closed to allow the safety control module to re-enable the safety circuit Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 30

I I Wiring diagram No. 1.2 Spring to lock solenoid P Fail-safe standstill monitor Fail-safe delay timer 1 Q1 Inputs PLC Outputs Q2 I2 3 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Safety circuit: Monitoring of one safety guard Monitoring of hazardous run-on motion 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Solenoid interlocks: AZM 161SK-12/12rk AZM 161CC-12/12rk AZM 161SK-33rk AZM 161CC-33rk AZM 415-22zpk TZFW Comments: Safety guard position as input signal to PLC After unlocking, the safety guard must be opened and closed to allow the safety control module to re-enable the safety circuit Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 31

I I Wiring diagram No. 1.3 Spring to lock solenoid P Fail-safe standstill monitor Fail-safe delay timer 1 Q1 Inputs PLC Outputs Q2 3 I2 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Safety circuit: Monitoring of one safety guard Monitoring of hazardous run-on motion 2 channel Solenoid interlocks: AZM 161SK-12/12rk AZM 161CC-12/12rk AZM 190-02/10rk Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: Safety guard position as input signal to PLC After unlocking, the safety guard does not need to be opened and closed to allow the safety control module to re-enable the safety circuit Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 32

I I Wiring diagram No. 1.4 Spring to lock solenoid P Fail-safe standstill monitor Fail-safe delay timer 1 Q1 Inputs PLC Outputs Q2 I2 3 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Safety circuit: Input circuit: Comments: Monitoring of one safety guard with a solenoid interlock and an second switch Monitoring of hazardous run-on motion 2 channel With start-up test Control category 4 to EN 954-1 (see general notes, page 28) Safety guard position as input signal to PLC After unlocking, the safety guard must be opened and closed to allow the safety control module to re-enable the safety circuit Solenoid interlocks: AZM 161SK-12/12rk AZM 161CC-12/12rk AZM 161SK-33rk AZM 161CC-33rk AZM 170-11zrk AZM 190-02/10rk AZM 415-22zpk TZFW Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 33

Wiring diagram No. 2.1 Spring to lock solenoid Fail-safe standstill monitor Fail-safe delay timer S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of multiple safety guards Multiple solenoid interlocks connected to one safety control module Monitoring of hazardous run-on motion Solenoid interlocks: AZM 170-02zrk Safety circuit: 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: After unlocking, a safety guard must be opened and closed to allow the safety control module to re-enable the safety circuit Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 34

I I Wiring diagram No. 2.2 Spring to lock solenoid P Fail-safe standstill monitor Fail-safe delay timer 1 Q1 Inputs PLC Outputs Q2 I2 3 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of multiple safety guards Multiple solenoid interlocks connected to one safety control module Monitoring of hazardous run-on motion Solenoid interlocks: AZM 161SK-12/12rk AZM 161CC-12/12rk AZM 161SK-33rk AZM 161CC-33rk AZM 415-22zpk Safety circuit: 2 channel TZFW Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: Safety guard position as input signal to PLC After unlocking, a safety guard must be opened and closed to allow the safety control module to re-enable the safety circuit Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 35

I I Wiring diagram No. 2.3 Spring to lock solenoid P Fail-safe standstill monitor Fail-safe delay timer 1 Q1 Inputs PLC Outputs Q2 3 I2 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of multiple safety guards Multiple solenoid interlocks connected to one safety control module Monitoring of hazardous run-on motion Solenoid interlocks: AZM 161SK-12/12rk AZM 161CC-12/12rk AZM 190-02/10rk Safety circuit: 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: Safety guard position as input signal to PLC After unlocking, a safety guard does not need to be opened and closed to allow the safety control module to re-enable the safety circuit Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 36

Wiring diagram No. 3.1 Spring to lock solenoid Fail-safe standstill monitor Fail-safe delay timer S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of multiple safety guards Multiple solenoid interlocks connected to one safety control module Monitoring of hazardous run-on motion All guards are unlocked using one switch Solenoid interlocks: AZM 170-02zrk Safety circuit: 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: After unlocking, a safety guard does not need to be opened because of the integrated actuator and solenoid contacts Not recommended for larger machines (see page 7) Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 37

I I Wiring diagram No. 3.2 Spring to lock solenoid P Fail-safe standstill monitor Fail-safe delay timer 1 Q1 Inputs PLC Outputs Q2 I2 3 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of multiple safety guards Multiple solenoid interlocks connected to one safety control module Monitoring of hazardous run-on motion All guards are unlocked using one switch Solenoid interlocks: AZM 161SK-12/12rk AZM 161CC-12/12rk AZM 161SK-33rk AZM 161CC-33rk AZM 415-22zpk TZFW Safety circuit: 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: After unlocking, the guards does not need to be opened because of the integrated actuator and solenoid contacts Not recommended for larger machines (see page 7) Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 38

I I Wiring diagram No. 3.3 Spring to lock solenoid P Fail-safe standstill monitor Fail-safe delay timer 1 Q1 Inputs PLC Outputs Q2 3 I2 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of multiple safety guards Multiple solenoid interlocks connected to one safety control module Monitoring of hazardous run-on motion All guards are unlocked using one switch Solenoid interlocks: AZM 161SK-12/12rk AZM 161CC-12/12rk AZM 190-02/10rk Safety circuit: 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: Safety guard position as input signal to PLC After unlocking, the safety guard does not need to be opened and closed to allow the safety control module to re-enable the safety circuit Not recommended for larger machines (see page 7) Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 39

I I Wiring diagram No. 4.1 Power to lock solenoid 1 Q1 Inputs PLC Outputs Q2 3 I2 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of one safety guard Solenoid interlocks: AZM 170-02zrka Safety circuit: 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: After unlocking, the safety guard must be opened and closed to allow the safety control module to re-enable the safety circuit Solenoid interlocks with power to lock may only be used for personal protection after a thorough evaluation of the accident risk. Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 40

I I Wiring diagram No. 4.2 Power to lock solenoid P 1 Q1 Inputs PLC Outputs Q2 3 I2 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Safety circuit: Monitoring of one safety guard 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Solenoid interlocks: AZM 161SK-12/12rka AZM 161CC-12/12rka AZM 161SK-33rka AZM 161CC-33rka AZM 415-22zpka Comments: Safety guard position as input signal to PLC After unlocking, the safety guard must be opened and closed to allow the safety control module to re-enable the safety circuit Solenoid interlocks with power to lock may only be used for personal protection after a thorough evaluation of the accident risk. TZMW Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 41

I I Wiring diagram No. 4.3 Power to lock solenoid P 1 Q1 Inputs PLC Outputs Q2 I2 3 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Safety circuit: Monitoring of one safety guard 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Solenoid interlocks: AZM 161SK-12/12rka AZM 161CC-12/12rka AZM 190-02/10rka Comments: Safety guard position as input signal to PLC After unlocking, the safety guard does not need to be opened and closed to allow the safety control module to re-enable the safety circuit Solenoid interlocks with power to lock may only be used for personal protection after a thorough evaluation of the accident risk. Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 42

I I Wiring diagram No. 4.4 Power to lock solenoid P 1 Q1 Inputs PLC Outputs Q2 3 I2 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Safety circuit: Input circuit: Comments: Monitoring of one safety guard with one solenoid interlock and a second switch 2 channel With start-up test Control category 4 to EN 954-1 (see general notes, page 28) Safety guard position as input signal to PLC After unlocking, the safety guard must be opened and closed to allow the safety control module to re-enable the safety circuit Solenoid interlocks with power to lock may only be used for personal protection after a thorough evaluation of the accident risk. Solenoid interlocks: Note: AZM 161SK-12/12rka AZM 161CC-12/12rka AZM 161SK-33rka AZM 161CC-33rka AZM 170-11zrka AZM 190-02/10rka AZM 415-22zpka TZMW The wiring diagram is shown with the safety guard closed and in de-energised condition. 43

I I Wiring diagram No. 5.1 Power to lock solenoid 1 Q1 Inputs PLC Outputs Q2 I2 3 Q3 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of multiple safety guards Multiple solenoid interlocks connected to one safety control module Solenoid interlocks: AZM 170-02zrka Safety circuit: 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: After unlocking, the guards does not need to be opened because of the integrated actuator and solenoid contacts Solenoid interlocks with power to lock may only be used for personal protection after a thorough evaluation of the accident risk. Not recommended for larger machines (see page 7) Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 44

I I Wiring diagram No. 5.2 Power to lock solenoid P 1 Q1 Inputs PLC Outputs Q2 3 I2 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of multiple safety guards Multiple solenoid interlocks connected to one safety conrtol module Solenoid interlocks: AZM 161SK-33rka AZM 161CC-33rka AZM 415-22zpka Safety circuit: 2 channel TZMW Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: Safety guard position as input signal to PLC After unlocking, a safety guard does not need to be opened because of the integrated actuator and solenoid contacts Solenoid interlocks with power to lock may only be used for personal protection after a thorough evaluation of the accident risk. Not recommended for larger machines (see page 7) Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 45

I I Wiring diagram No. 5.3 Power to lock solenoid P 1 Q1 Inputs PLC Outputs Q2 I2 3 Q3 S11 S12 S21 S22 Channel 1 Channel 2 Safety control module Features Product selection Description: Monitoring of multiple safety guards Multiple solenoid interlocks connected to one safety control module Solenoid interlocks: AZM 161SK-12/12rka AZM 161CC-12/12rka AZM 190-02/10rka Safety circuit: 2 channel Input circuit: Control category 3 to EN 954-1 (see general notes, page 28) Comments: Safety guard position as input signal to PLC After unlocking, a safety guard does not need to be opened and closed to allow the safety control module to re-enable the safety circuit Solenoid interlocks with power to lock may only be used for personal protection after a thorough evaluation of the accident risk. Not recommended for larger machines (see page 7) Note: The wiring diagram is shown with the safety guard closed and in de-energised condition. 46

I I Wiring diagram No. 6.1 Fail-safe standstill monitor L1 L2 L3 P 3 M 1 Q1 Inputs PLC Outputs Q2 3 I2 Q3 X1 X2 X4 13 14 N Unlocking solenoid Features Product selection Description: Standstill monitoring using 1 or 2 pulse generators In case of 1 pulse generator, a jumper between X1 and X2 is required Additional standstill signal from the PLC Fail-safe standstill monitor: FWS 1206 Note: The wiring diagram is shown in de-energised condition. 47

Wiring diagram No. 6.2 Fail-safe standstill monitor L1 L2 L3 P 3 M X1 X2 13 14 N Unlocking solenoid Features Product selection Description: Standstill monitoring using 1 or 2 pulse generators In case of 1 pulse generator, a jumper between X1 and X2 is required Fail-safe standstill monitor: FWS 1205 Note: The wiring diagram is shown in de-energised condition. 48

Wiring diagram No. 6.3 Fail-safe standstill monitor P L1 L2 L3 3 M Y2 X3 X5 13 14 N Unlocking solenoid Features Product selection Description: Standstill monitoring using 2 pulse generators Fail-safe standstill monitor: FWS 2316C Comments: Cross-wire monitoring of the pulse generators Note: The wiring diagram is shown in de-energised condition. 49

Wiring diagram No. 6.4 Fail-safe standstill monitor P L1 L2 L3 3 M I 13 N 14 N Unlocking solenoid Features Product selection Description: Standstill monitoring using 1 pulse generator Fail-safe standstill monitor: EBW Note: The wiring diagram is shown in de-energised condition. 50

Wiring diagram No. 6.5 Fail-safe standstill monitor P L1 L2 L3 3 M L1 L2 L3 13 14 Unlocking solenoid Features Product selection Description: Sensor-free monitoring of standstill using e.m.f. Fail-safe standstill monitor: AZR 31 S1 Note: The wiring diagram is shown in de-energised condition. 51

Wiring diagram No. 7.1 Fail-safe delay timer P S13 S14 S21 S22 13 14 Unlocking solenoid Features Product selection Comments: Timer starts when contacts S13-14 / S21-22 change state Fail-safe delay timer: AZS 2305 Note: The wiring diagram is shown in de-energised condition. 52

Terminal definition of the safety solenoid interlocks used in the wiring diagrams Spring to lock Power to lock AZM 170 A2 A1 A2 A1 A2 A1 A2 A1 32 21 32 21 32 21 32 21 22 12 32 11 14 13 AZM 170-02zrk AZM 170-11zrk AZM 170-02zrka AZM 170-11zrka 22 12 32 11 14 13 AZM 161 A1 A2 A1 A2 A1 A2 A1 A2 13 21 14 22 51 52 13 21 51 71 14 22 52 72 13 14 21 22 51 52 13 14 21 22 51 71 52 72 AZM 161SK-33rk AZM 161CC-33rk AZM 161SK-12/12rk AZM 161CC-12/12rk AZM 161SK-33rka AZM 161CC-33rka AZM 161SK-12/12rka AZM 161CC-12/12rka TZF / TZM E1 E2 E1 E2 21 22 21 22 33 11 34 12 33 34 11 12 TZFW TZMW AZM 190 E1 E2 E1 E2 21 22 31 32 13 14 AZM 190-02/10rk 21 22 31 32 13 14 AZM 190-02/10rka AZM 415 A1 A2 A1 A2 21 23 22 24 11 12 AZM 415-22zpk 21 23 11 22 24 12 AZM 415-22zpka 53

Glossary A C Additional transistor output: An indication output which shows the condition of the evaluation unit or the guard device or gives an error code. AES: Electronic evaluation unit for safety functions (Safety control module). Appliance safety law: The appliance safety law forms the basis to put the EC Recommendations to Article 100a of the Articles of Rome into effect in national law. The individual EC Recommendations are put into effect by decrees. These apply to manufacturers and importers. Cascading: Series-parallel circuits, e.g. of safety switching devices. Change-over contact with double break: On actuation, opens and closes an electrical circuit at two contact points in each case, see contact diagrams. Change-over contact with single break: On actuation, opens and closes an electrical circuit at one contact point in each case, see contact diagrams. Contact diagrams to IEC 60617: Single break contact with 2 terminals Symbol Illustration Type A B Double-break contact with 2 terminals Symbol Illustration Type X Y Change-over contact with single break, with 3 terminals Symbol Illustration Type C D E Contactor with positively guided contacts: Contactor or relay on which the NC and NO contacts are galvanically separated from each other but mechanically connected together. Control category: For the risk assessment to EN 954-1 for safety-relevant electrical circuits, there are five categories for safety related parts of control systems. These categories B, 1, 2, 3 and 4 describe the resistance of a control system to faults. Conventional relay technology: The device is not equipped with microprocessors. Control and evaluation for instance of a safety guard monitor is carried out using relays. Cross-wire monitoring of two adjacent contacts or switches, e.g. between S13 and S22. A safety control module can monitor this condition. Declaration of Conformity: Declaration issued by the manufacturer for the use of a product within the European Community according to the appropriate standards. Diversely programmed micro-processor: Two different programs for the same function, in order to recognise software errors. Drop-out delay: Voltage-controlled drop-out of the relay after a preset or fixed time. EMC Directive: Law on electromagnetic compatibility. The EMC Directive applies to appliances which contain electrical and/or electronic components which can cause electromagnetic interference or the operation which can be affected by such interference. Emergency release: allows for a manual release of the solenoid interlock from outside the hazardous area without assistance in case of an emergency. The resetting of the operational state must require an effort comparable to a repair action. Change-over contact with double break, with 4 terminals Note: The contacts are same polarity Symbol Illustration Type Change-over contact with double break, with 4 terminals The two contact bridges are galvanically separated from each other Symbol Illustration Type Contact/Switch travel: The contact/switch travel details shown in the catalogue illustrate the switching behaviour on actuation from position 0 (= unactuated) up to the maximum end position. Closed contacts are represented by dark shading and open contacts by white areas. Other features are shown by means of symbols which are explained inside the back cover. Za Zb Contactor check: See feedback circuit. Emergency Stop EN 60204-1: Actions in case of emergency Stopping in emergency: An action in a case of emergency which is determined to stop a process or movement which is dangerous. Switching off in emergency: An action in a case of emergency which is determined to cut off the electrical supply to a complete or a part of an electrical installation, if there is a risk of an electric shock or some other risk of electrical origin. Emergency exit: allows a manual unlocking of the solenoid interlock from inside the hazardous area without assistance in case of danger. Enabling output: Safety outputs, which are monitored for correct function by a safety control module. Enabling path: An enabling path is the safe output of the safety control module which can be integrated in the safety circuit of the machine. In the safe switched-off condition, this circuit must always be open, since the safe condition must always be reached by switching off the electrical supply ( failsafe mode of operation). The enabling path is formed by the NO contacts of the safety relays wired in series. 54

Glossary F G H I Entry / Intervention time: Time needed for entry into or intervention in the dangerous area, as calculated based on an approach speed. Exposure to risk: Probability of the occurrence of an injury or damage to health. The exposure to risk is related to the frequency of access to or time spent in the hazardous area. Fail-safe locking mechanism: The design of the solenoid interlock ensures that the locking and the position of the safety guard can be simultaneously monitored by means of one contact array. Under all circumstances, it must be guaranteed that the contacts can close only after the safety guard is properly closed. Fail-safe standstill monitor which gives the enable signal, when a machine has come to a standstill, e.g. to open a guard device. In case of a fault, the fail-safe standstill monitor takes up the safe condition. See also standstill monitor. Fail-safe timer (AZS range): A timing relay which gives an enable signal, when a preset time has elapsed, e.g. to open a guard device. In case of a fault, the fail-safe timer takes up the safe condition. Feedback circuit: Electrical circuit to monitor externally connected power contactors, etc., by means of a safety control module. The NC contacts are used to check wether external relays or contactors have taken up their safe condition (switched off) before their renewed energisation. The evaluation unit only gives the enable signal, when the feedback circuit is closed. GS-ET...: Testing/Inspection principles of the German assessment committee for electrical engineering GS-ET-15: Testing/inspection principles for positive break position switches GS-ET-19: Testing/inspection principles for locking devices with electromagnetic interlocking mechanism GS-ET-20: Testing/inspection principles for relay safety combinations Hazard: The word "hazard" appears very often in the Machinery Directive and the standards, in particular in word combinations, is however not commented on nor defined. It stands for an indefinite and not oriented hazard (i.e. not aimed directly against persons and/or objects). Hazardous area: Any area in or around a machine in which a person is at risk of injury or danger to health. Note: The hazard which produces the risk is either always present or can occur unexpectedly. In newer proposals, the term "Hazard zone" is also being used for this. Input extension: To monitor several safety guards, modules can be linked together using parallel wiring. Input expander, modular: To monitor a number of safety guards; modules are connected together by ribbon cables. Interlock: A mechanical, electrical or other device to prevent operation of a machine element under pre-determined conditions (usually as long as a movable safety guard is not closed). L M N O P ISD (Integral System Diagnostics): With the assistance of the ISD, the switching conditions and possible errors in case of a fault can be quickly identified. Depending on the version of the safety control module, the switching conditions and faults are shown via multi-colour LED s or provided to the user on a transistor output. The switching conditions and faults can be identified with the assistance of the ISD tables. IP 54, IP 65, IP 67: Indications for the existing protection classes of a switching device according to EN 60529 1st figure: protection against the ingress of solid foreign bodies 5 = dustproof 6 = dust-tight 2nd figure: protection against the ingress of water 4 = spray-proof 5 = jet-proof 7 = intermittent submersion without harmful effect Latching push button: Switch that has to be actuated manually Machine to EN 292-1; 3.1: The entirety of parts or devices connected together, of which at least one is a moving part, also as applicable drive elements, control and supply circuits, etc., which are brought together for a particular application, such as processing, treating, material handling and preparation of material. The entirety of several machines, which are so arranged and controlled that they operate together as a single unit to achieve one and the same purpose, is also considered to be a machine. Manipulation in a simple manner: Intentional overcoming of safety switches either manually or by using readily available items, e.g. screws, keys, coins or tools which are needed for the normal operation of the machine. See protection against manipulation. Manual release: allows for a manual release of the solenoid interlock from outside the danger zone by means of a tool or key. MBL...: Code of practice of German industrial assessors, which gives references and suggestions regarding technical products, Non-separating protective device: A device without separating function, which eliminates or reduces a risk either alone or in combination with a separating protective device. Normally closed contact / NC contact: A contact which is closed in the rest condition. Normally open contact / NO contact: A contact which is open in the rest condition. Output expander, modular: To provide additional enabling paths; modules are connected together by ribbon cables Output extensions: To increase the number of enabling circuits; modules can be linked together using parallel wiring. Positive action to EN 60947-5-1: Connection between the actuator and the switch contact by means of which force exerted on the actuator is directly transmitted to the contact. 55

Glossary P Positive actuation: If a moving mechanical component automatically moves another with it either by means of direct contact or via rigid parts. Positive break A (of a switch contact to EN 60204-1): The version of a contact separation as direct result of a determined movement of the operating part of the switch via nonflexible parts. Risk assessment: A complete assessment of the probability and the severity of possible injury or damage to health in a dangerous situation, in order to select suitable safety measures. In EN 1050, this term is used as a part of the risk analysis. Risk evaluation: A process to determine whether a risk is acceptable, based on risk analysis and taking into account factors such as social, commercial and environmental aspects. Positive drive (EN 60204-1): The actuator and the normallyclosed contact must be directly connected together via rigid (non-springing) parts. Power to lock solenoid: the latching bolt of a solenoid interlocking device is held in the locked position by solenoid force and released by spring force Protect: For the Protect mode of operation, the enable of the switching output is carried out automatically after the end of the protected field interruption (or in case of activation of the restart interlock after resetting) and the end of the protected field interruption. Protection against manipulation: Manipulation is when the function of a safety device or safety switch is made inoperative. S Risk judgement: A process of risk analysis and risk evaluation. In EN 292-1, these terms are not used in the same sense. Safety is present if the risk is justifiably small or in the absence of risks. Safety guard (EN 60204-1): A movable protective device or such as is used as a safety measure in order to protect persons from a present or potential hazard. Safety relay: The main characteristic of a safety relay is that it has positive-drive contacts, which makes it possible to check the position of its NO contacts by means of a NC contact. The contacts are mechanically connected together. It is thus ensured that the NC contact is always open when the NO contact is closed. R 56 Protection class IP (Enclosure rating): Protection against the ingress of solid foreign bodies (Foreign body protection) Protection of persons against contact with live or moving parts (Protection against contact) Protection against the ingress of water (Water protection) Reaction time (EN 61496): The maximum time duration between the response of the sensor function and the OFF condition of the output switching elements, see also response time. Redundancy (EN 60204-1): Use of more than one device or system, in order to ensure that in case of faulty operation of one unit the function will be carried out by the other one. Remaining risk: Risk which remains after carrying out protective measures; the remaining tolerable risk in spite of protective measures. Response time, reaction time: The maximum period of time between actuation of the sensor function and the OFF condition of the output switching elements. Re-start interlock: A device to prevent the automatic restart of a machine after interruption and renewed enable of the protected field during a dangerous part of the machine cycle or after a change in the mode of operation or actuation of the machine. Risk (EN 60204-1): A combination of the probability and the severity of the possible injury or damage to health of a dangerous situation, see EN 292-1, 3.7. The risk, in relation to the hazard seen, is also designated as a function of the amount of possible damage and the probability of this damage occurring. Risk analysis: A complete identification and evaluation of all possible dangers for the risk evaluation, also termed danger analysis in the Machinery Directive. According to Article 100a, the risk situation and exposure to risk must be taken into account, according to Article 118a, the potential risk depends on the working conditions and the working environment. Sensorless standstill monitors: Monitoring of the rotation of the motor is not carried out by sensors on the shaft but by direct monitoring of the back e.m.f. at the motor terminals. Slow action contact: Switching system where the switching movement depends on the actuating speed. Snap action contact: Switching system where the switching movement is carried out by spring action and is independent of the actuating speed. Solenoid interlock: A solenoid interlock has the function of locking a separating guard device in the closed position. It is connected to the control system in such a way that the machine cannot be operated if the safety guard is not closed and interlocked and that the safety guard is held closed until there is no longer a risk of injury. Spring to lock solenoid: the latching bolt of a solenoid interlocking device is held in the locked position by spring force and released by solenoid force Standards regarding machine safety are classified in three types: Type A standards: The basic safety standards, which lay down the basic terms and the guiding principles for all machines. Type B standards: Safety group standards, which deal with a particular safety aspect that is applicable to a wide range of machines. Type B1 standards: Make more concrete statements and offer possible solutions for the safety aspects dealt with generally in the basic standards, such as safe distances, surface temperatures, etc. Type B2 standards: Include concrete statements or possible solutions for safety equipment such as two-hand operation circuits, interlocking devices, etc. Type C standards: Machine safety standards or subject standards which relate to specific safety characteristics of individual types of machine or of machine groups.

Glossary Standstill frequency: A programmed fixed reference value for recognition of standstill. On frequency standstill, the enable circuits are switched on and solenoid interlocks connected can be opened. Start disable: A function which causes the BWS to go into an interlocked condition when its electrical supply is switched on or interrupted and switched on again. Start function: The feedback circuit can also be used to provide a start function by connecting an additional Start push button (NO) into the feedback circuit. The evaluation unit only gives the enable signal when the feedback circuit is closed. Start-up test: A manual or automatic test to EN 61496-1, which is carried out when an ESPE or a safety guard monitor has been switched on, to test the complete safety-related control system before the first machine movement is started. Stop category 0 to EN 60204-1: Shutdown by immediate switching-off of the power supply (uncontrolled shutdown). Stop category 1 to EN 60204-1: When switching off, the supply is maintained until the machine has come to a standstill. When standstill has been reached, the power supply is interrupted (controlled shutdown). Stop category to EN 60204-1: Division to describe the switching-off characteristics relating to actions in emergencies. T Stopping time: Duration until the hazard is removed, e.g. motor standstill. Test push button: The Test push button can be used to check the switch-off function of an evaluation unit. When the Test button is operated, the enable contacts must open. Time monitoring is only operative in stroke operation (single or double stroke). It prevents uncontrolled release of the machine stroke. This provides that interventions in the protected field are only accepted as strokes when they are carried out within a pre-determined time (e.g. 30s) after the stroke cancellation contact is closed. If this does not take place within this period of time, the re-start interlock is activated. U Timer: A timing relay which gives an enable signal when a preset time has elapsed, e.g. to open a guard device. In case of a fault, the secure timer takes up the safe condition. Universal current (UC): Devices can be operated on AC or DC supplies. 57

Explanation of symbols Emergency stop........................ Safety guard........................... SA approval, Sweden................... E UL approval, USA....................... C Safety light barrier...................... Safety light curtain...................... UL/CSA approval, USA................ CSA approval, Canada.................. D Laser scanner.......................... Pull-wire switch......................... Two-hand control....................... CSA/UL approval, Canada.............. TÜV prototype-tested.................. F BG prototype-tested..................... H Safety mat............................ Safety sensor.......................... Fail-safe standstill monitor................ Fail-safe delay timer..................... Removable safety guard.................. Hinged safety guard..................... Sliding safety guard..................... Safety guard in aluminium profiles.......... Control Category 1 to EN 954-1............ K Control Category 2 to EN 954-1............ L Control Category 3 to EN 954-1............ M Control Category 4 to EN 954-1............ N NC contact with positive break............. A Spanner size across flats................. i Directive conformity, see declaration of conformity.............. Integrated system diagnosis................ ISD Rated insulation voltage................... U i Thermal current test...................... I th Rated operating voltage................... U e Rated operating current.................... I e Rated control voltage..................... U s Minimum actuating radius................ R min........................................................... R min. R min. 58

References The solenoid interlocks of the Schmersal Group comply to the latest editions of the standards. The following standards and technical data sheets are a guide to the design, operating principle, mounting and technical requirements of solenoid interlocks, and the safety relevant equipment on machinery: Standards: EN 292: Safety of machinery: Basic concepts, general design principles EN 953: Safety of machinery: Movable safety guards The Schmersal Group has published two technical books about machine safety in German. Several chapters of these books also contain detailed notes for the selection and the design of safety guards fitted with solenoid interlocks. An English version will be available in autumn 2002: Werner Defren/ Dr. Karl Wickert: Sicherheit für den Maschinen- und Anlagenbau. Wuppertal, 2. Auflage 2001, ISBN 3-926069-10-4 Werner Defren/ Franz Kreutzkampf: Personenschutz in der Praxis. Wuppertal 2001, ISBN 3-926069-11-2 EN 954-1: Safety of machinery: Principles for the design of safety-related parts of control systems EN 999: Safety of machinery: Classification of safety guards taking into account the approach velocity of body parts EN 1037: Safety of machinery: Avoiding unexpected start-up EN 1088: Safety of machinery: Interlocking devices associated with guards EN 60204: Safety of machinery: Electrical equipment of machines EN 60947: Low voltage switchgear and control gear These standards can be obtained from Beuth Verlag GmbH Burggrafenstraße 6 10787 Berlin Internet: www2.beuth de Email: postmaster@beuth.de Other documentation: BG technical data sheet: BGI 575 (in preparation): Selection and installation of electromechanical interlocking devices for safety functions BIA-Report 6/97: Categories for safety-relevant parts of control systems to EN 954-1 Even more information is available on the Internet: www.schmersal.com www.zvei.org www.hsebooks.co.uk Search word: safeguarding www.europa.eu.int MRL-News: News about Safety of Machinery and Machine Controls by Elan Schaltelemente GmbH & Co. KG 59

K. A. Schmersal GmbH Safety Control Systems Möddinghofe 30 D - 42279 Wuppertal P.O. Box 24 02 63 D - 42232 Wuppertal Germany Phone +49 - (0)2 02-6474- 0 Fax +49 - (0)2 02-6474- 1 00 E-Mail info@schmersal.de Internet www.schmersal.com Elan Schaltelemente GmbH & Co. KG Im Ostpark 2 D-35435 Wettenberg Germany Phone +49 (0)641-9848 - 0 Fax +49 (0)641-9848 - 420 E-Mail info@elan.schmersal.de Internet http://www.elan.de 3.000/L.D./12.2003/Teile-Nr. 1162670/Ausgabe B