Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Similar documents
Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

SOLENOID VALVES AND PNEUMATIC VALVES

3/2-way Mini Solenoid Valve

4/2-Way Pneumatic Solenoid Valve

Assisted lift operated 2/2-way solenoid valves Type EV250B

SOLENOID VALVES 3-4 WAY

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

4 Posiflow Proportional Solenoid Valves

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

FRL/AirCare Air Controls & Accessories

3 Port Solenoid Valve

Electro-pneumatic control valves

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2- and 2/2-way cartridge valve type BVE

Model 43AP Pneumatic Controller, Style B

PRESSURE REDUCING CONTROL VALVE

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

Hydraulic control unit series

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Series IDU/IDF. Refrigerated Air Dryer

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Digital inductive conductivity transmitter

3 Port Solenoid Valve

MANTA Piston Distributor for Oil and Fluid Grease

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Series M Applicable Tubing: ø2 Connection Thread: M3, M5

MEMBRANE VACUUM MINI PUMPS

2/2 and 3/2 Way Size 6 Seat Valves

BERMAD Fire Protection

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

size size

Electro-Pneumatic Bus Door Control Mechanism

For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } {175}

Single sub-base valve

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Unit 24: Applications of Pneumatics and Hydraulics

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Manual piston sampler...m 11

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

NAMUR Mount Hygienic Valve

Digital Flow Switch for Water 3 -color/2-screen display

G1/4 Q8. Standard with biased position

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

VSO MAX HP High Flow Proportional Valve

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

5 Port Solenoid Valve

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Solenoid valves 2/2-way direct-operated Type EV210A

V47 Series Temperature Actuated Modulating Water Valves

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Sporlan V-Series Ruby Seat Solenoid Valves

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

OLI. Oil level indicator

Proportional pressure regulators VPPE

PET-10 INSTRUCTION MANUAL PRESSURE TANK

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

POWER PULSE VALVES remote pilot threaded or Quick Mount connection 3/4 to 1 1/2

Instruction Manual. ThinkTop Basic Digital VDC PNP/NPN ESE00225EN

TIMER CONTROLLED DRAINS

ATL Fuel Level Sender Probes

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

Industrial Hydraulic Remote Controlled Monitor

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

SMD Rework Station TABLE OF CONTENTS

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

servo-controlled 3-WaY vacuum solenoid valves WiTH

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Example. Fluid Power. Circuits

PART 2 FORKLIFT HYDRAULIC SYSTEM

Valve systems Base plates, according to standard ISO Brochure

Valves. Sub-Base Mounted Valves to ISO 5599/2

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Adams. Spray Lubrication

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Transcription:

Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective capacity: mbient and fluid temperature Solenoid valve voltage to C VC /Hz, VC /Hz, VDC Rc / Port size : T (ø tube) applicable OUT x Rc / : T (ø tube) applicable OW : T (ø tube) applicable Weight (kgf).. Control Circuit MU- Supply ON/OFF valve for oil mist Regulator for tank setting Supply Pressure gauge for supply MU- Pressure gauge for supply Regulator for tank setting pplication Examples ON/OFF valve for air blow for tank Fixed orifice Oil tank ON/OFF valve for oil mist Oil tank for tank Fixed orifice MU MU OW Mist spray unit Standing type machining center (Drilling center) ir blow circuit vailable Not available Rated voltage VC (/ Hz) VC (/ Hz) VDC Recommended Equipment Float switch None For the upper and lower limit control SW turns OFF when the float is on the upper side. SW turns ON when the float goes down. Contact capacity V C, W DC ( ) It is recommended to use each mist spray unit type with the mixing valves, magnet holders, branch pipes and nylon tubes listed in the table below. Mist spray unit This unit, with an oil tank and a spray ON/OFF control unit, sends oil and air to the mixing valve. MU- MU- Mixing valve This valve adjusts the amounts of oil and air from the mist spray unit using built-in oil and air needles, and also discharges oil mist from the nozzle. MV- MV- MV- MV- Magnet holder This magnet holder enables the mixing valve installed on the arm end to be freely attached to the iron and steel parts such as machining tools, etc. MH MH ranch pipe This pipe is used to separate oil and air from the mist spray unit when using several mixing valves. MD- MD- Horizontal machining center Nylon tube This tube is used for the air piping and oil piping between the mist spray unit and the mixing valve. T T OW T T T Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C --Main Office: () --Outside ocal rea: () --www.stevenengineering.com F T D MU IP

Series MU Construction/Working Principle MU- Oil Discharge Rate (Representative Value) Conditions Oil: Turbine oil class ISO VG Oil temperature: C for supply ON/OFF valve for air blow ON/OFF valve for oil mist ir adjusting needle for mist Oil adjusting needle Mixing valve (MV - ) Diaphragm Double pipe nozzle Oil discharge rate cm /min. MPa Oil tank. MPa. MPa. MPa Regulator for tank setting for tank Oil level gauge Fixed orifice ubrication plug Oil filler strainer Strainer... Number of oil needle rotations (turns) ir flow rate (Representative Value) MU- for supply Diaphragm ON/OFF valve for oil mist ir adjusting needle for mist Oil adjusting needle Mixing valve (MV - ) Double pipe nozzle ir flow rate l/min(nr). MPa. MPa. MPa. MPa.... Number of air needle rotations (turns) Regulator for tank setting for tank Oil level gauge Fixed orifice ubrication plug Oil filler strainer Strainer Working Principle Of the compressed air from the air source, part is directed to the regulator for tank setting (), while the rest is directed to the ON/OFF valve for oil mist (), which operates the ON/OFF valve for the air blow circuit () and the pilot valve for the mixing circuit (). Compressed air at a prescribed setting determined by the regulator for tank setting () passes through the fixed orifice () and gradually fills the oil tank (), applying to the surface. The in the tank passes through the strainer () and is drawn into the pilot valve (). Operating the ON/OFF valve for oil mist () at this point will cause operating signal to be conducted into the pilot valve (), pushing the diaphragm () downwards, and as a result the compressed air from pilot valve () and oil from the opened valve will flow through their respective conduits and be drawn into the mixing valve (). ir and oil are adjusted with varying quantities by the air for mist from the mixing valve () and oil adjustment needles () and (). With dual piping from the mixing valve () to the dual pipe nozzle (), compressed air passes through the outside while oil passes through the inside, and at the tip of the dual pipe nozzle () they are sprayed out as a fine mist by the discharged air. To remove cutting chips, operate the ON/OFF valve for air blow (), which will cause the supplied compressed air to be drawn directly into the mixing valve () and blown out as air through the external piping of the dual pipe nozzle (). To replenish oil, loosen the oil supply plug () to discharge the compressed air from inside the tank through the oil supply plug s side hole. Since it flows gradually from the fixed orifice () into the interior of the tank, it is easy to replenish oil from the oil supply hole. Handling Precautions Mounting. e sure to mount an air filter corresponding to mm (equivalent to the F) on the side of the mist spray unit. djustment. fter loosening the tank s -setting handle (by rotating it to the left), introduce air from the air source. Use the tank s setting handle and set the range from. to. MPa, set each control valve to ON (manual operation or energized), and inspect carefully to make sure there is no looseness in the fittings at each connecting point. t this time, be sure the air and oil adjustment needles of the mixing valve are in a completely closed position (by rotating it to the right.) ubrication. Completely release air in the pipe. Even small amounts of air in the pipe will cause oil to dribble. Fully open the oil adjustment needle of the mixing valve, and turn the ON/OFF valve for oil mist generation to the ON position, or press and hold down the manual button to release all air from inside the pipe. If air buildup from use of branching pipes, etc. takes place inside the pipe, mount an air release valve at the highest position and let the air out. e sure to carry out this operation when replenishing the oil after the oil tank becomes empty. Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C --Main Office: () --Outside ocal rea: () --www.stevenengineering.com

Mist Spray Unit Series MU /Parts ist MU MU. OW R. O CK Regulator for tank setting ubrication plug ubrication plug ON/OFF valve for oil mist ON/OFF valve for air blow Regulator for tank setting ON/OFF valve for oil mist Supply gauge Supply gauge. R.. RC RC Tank gauge OW OC K Tank gauge.. Main Parts ist Mist spray body Mist spray tank Material luminum die-casted luminum die-casted Note Spare Parts/Replacement Parts Part Material Qty. Part no. MU MU ody seal Element ubrication plug Filler seal evel gauge Type C retaining ring for hole Regulator Solenoid valve NR ronze rass Hard glass Stainless steel FKM NR FKM - - - - - JIS Nominal JIS P G-- G---X P JIS P JIS P IN-- VO- G-X Solenoid valve VO- G NR JIS P Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C --Main Office: () --Outside ocal rea: () --www.stevenengineering.com F T D MU IP

Related Products Mixing Valve: Series MV MV MV Specifications Inlet air mbient and fluid temperature Port size OW MV Mixing valve vailable Not available Nozzle tubing construction Flexible tubing Copper tubing. MPa Max. to C T (ø tube) applicable T (ø tube) applicable T (ø tube) applicable Nozzle tubing length: mm mm mm mm Construction MV /With air blow circuit ir adjusting needle for mist Oil adjusting needle Mixing valve (MV - ) Double pipe nozzle MV - () ø Cross section () ø. ø... MV /Without air blow circuit ir adjusting needle for mist Oil adjusting needle.. OW. Cross section T (ø x ø) pplicable tubing T (ø x ø.) pplicable tubing T (ø x ø) pplicable tubing (Max.) Dimension Symbol ength (mm) Mixing valve (MV - ) Double pipe nozzle MV - () C D. E.... x ø. Main Parts ist Mixing valve body T (ø x ø) pplicable tubing (Max.) T (ø x ø.) pplicable tubing Cross section CDE Material luminum die-casted Note Dimension Symbol ength (mm) Spare Parts/Replacement Parts Part Part no. Material Qty. MV MV Flexible nozzle assembly -- to Note ) Copper piping nozzle assembly -- to FKM - Note ) Numbers indicate nozzle lengths. : mm, : mm, : mm, : mm Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C --Main Office: () --Outside ocal rea: () --www.stevenengineering.com Note )

Related Products Magnet Holder: Series MH MH Magnet holder Symbol Construction vailable Not available pplicable mixing valve model MV MV MH MH MD MD ranch Pipe: Series MD ranch pipe MD vailable Not available of mixing valves MD x ø. x Rc/ n = Rc / MD- MD- MD- MD- MD- MD- n n: Stations l MD x ø. x ø. n x Rc/ x Rc/ MD- MD- MD- MD- MD- MD- n n: Stations l...... Courtesy of Steven Engineering, Inc.- Ryan Way, South San Francisco, C --Main Office: () --Outside ocal rea: () --www.stevenengineering.com F T D MU IP