DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BQ 036, 048 & 060 254575-XTG-C-0109

Similar documents
SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Split System Cooling Product Data

Split System Heat Pump Product Data

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

CE6500 Energy Recovery Ventilator

TWE+TTA TWE+TWA T.R.

ARMSTRONG AIR HEAT PUMPS

Product Data. Split System Cooling F-EN. March 2015

SECTION HEAT PUMPS

Packaged Cooling with Electric Heat Rooftop Units

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Commercial Gas Furnace Upflow

Split System Cooling Product Data

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

GCS16 GCS20 WARNING CAUTION

SECTION AIR CONDITIONING UNIT

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

catalog Single Package Vertical Air Conditioners and Heat Pumps

MAC-120HE-01 Air-Cooled Chiller

Split System Cooling Product Data

Installation Instructions

Cooling/Heat Pump Convertible Air Handlers

GCS

Split System Heat Pump Product Data

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

ECOCIAT. Domestic hot water heat recovery unit

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Split System Heat Pump Product Data

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Packaged Gas/Electric Rooftop Units

Liebert DS Thermal Management Unit

, User s Manual

Bring the fresh in. Dedicated Outside Air Systems

THE WALL-MOUNT TM HEAT PUMPS - (60HZ)

180, 210, AND 240 MODELS LCA PACKAGED COOLING & ELECTRIC HEAT LGA PACKAGED COOLING & GAS HEAT LHA PACKAGED HEAT PUMP

50LC Ultra High Efficiency Cooling Only/Electric Heat Packaged Rooftop 3 to 5 Nominal Tons Product Data

Split System Cooling Product Data

Packaged Gas/Electric Rooftop Units

HP switch LP switch Discharge thermo Comp. Surface thermo

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

WALL MOUNTED PACKAGED AIR CONDITIONER INSTALLATION INSTRUCTIONS. Models: WA182, WA242. Bard Manufacturing Company, Inc.

Explosion-Proof Electric Unit Heaters

Split System Heat Pump Product Data

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

USER S MANUAL HSC-24A

york air-conditioning products Residential & VRF News 2015

WALL MOUNTED PACKAGED AIR CONDITIONER INSTALLATION INSTRUCTIONS. Models: WA301, WA361. Bard Manufacturing Company Bryan, Ohio 43506

Air Conditioners Technical Data

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Glossary of Heating, Ventilation and Air Conditioning Terms

Split System Cooling Product & Performance Data

HEATER, AIR CONDITIONING AND VENTILATION

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

FTQ. Daikin Inverter Ducted Heat Pump

E2 Series Electric Furnaces

SECTION MORTUARY REFRIGERATORS

PANASONIC TROUBLE SHOOTING GUIDE


Cooling Capacity CFM in. w.c. (125 Pa)

Low Profile Unit Cooler

TABLE OF CONTENTS MAINTENANCE & TROUBLESHOOTING

WALL MOUNTED PACKAGED WA372. Bard Manufacturing Company Bryan, Ohio Manual No.: Supersedes: File: Volume III, Tab 16 Date:

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

F9MXE. Product Specifications

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Element D Services Heating, Ventilating, and Air Conditioning

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

CB29M Bulletin # February 1996

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

SPLIT-SYSTEM CONDENSING UNITS SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES

MAINTENANCE & TROUBLESHOOTING INSTALLATION TABLES FIGURES OPERATION START-UP

Technical data. Danfoss DHP-A

Greensource iseries HY Model Unitary Air Handler/Fan Coil

MovinCool Office Pro Series. The Portable Spot Cooling Solution

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Operation and Installation Manual. Max Series

Condensing unit type EPSILON-ECHOS LE Technical information manual

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

Diesel Engine Driven Generators Page 1 of 6

Cased/Uncased Coils For Gas And Oil Furnaces

Transcription:

TECHNICAL GUIDE SINGLE PACKAGE HEAT PUMP UNITS BQ 036, 048 & 060 3, 4 & 5 NOMINAL TONS (Export 50 Hz) DESCRIPTION YORK Sunline 2000 TM heat pumps are convertible single package units with a common cabinet and a common roof curb for the 3, 4 and 5 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. These heat pumps utilize a unique ambient compensated time-temperature defrost system. The defrost module automatically increases the time interval between defrost cycles as the outdoor ambient temperature decreases. This helps to eliminate unnecessary and costly defrost cycles. All units include: Powder Paint finish that meets ASTM-B-117 1000 hour salt spray standards Permanently lubricated motors Bottom or side air discharge configuration capability (field convertible) Manufactured under the quality standards of ISO9001 Simplicity Control Board Copper tube/aluminum fin coils Easy access to all components Rigging holes in base rails for lifting Fork lift slots on three sides Single point power connection Complete factory package - tested, charged and wired FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

TABLE OF CONTENTS DESCRIPTION............................. 1 TABLE OF CONTENTS....................... 2 PRODUCT NOMENCLATURE................. 3 FEATURES................................ 4 FACTORY-INSTALLED OPTIONS.............. 5 FIELD-INSTALLED ACCESSORIES............. 6 LIST OF FIGURES 1 UNIT CUTAWAY......................... 5 2 TYPICAL FIELD POWER & CONTROL WIRING............................... 20 3 UNIT DIMENSIONS (3-5 TON HEAT PUMP) FRONT VIEW........................... 21 4 UNIT WITH ECONOMIZER RAINHOOD...... 21 5 UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD..... 22 6 UNIT DIMENSIONS (REAR VIEW).......... 22 7 DISCONNECT/BLOWER ACCESS LOCATION............................. 23 8 TYPICAL APPLICATIONS................. 24 9 FOUR AND SIX POINT LOADING........... 25 10 ROOF CURB DIMENSIONS............... 26 LIST OF TABLES 1 SOUND POWER RATING.................. 7 2 CAPACITY RATING (COOLING)............. 7 3 CAPACITY RATING (HEATING)............. 7 4 BQ036 COOLING CAPACITIES (3 TON)...... 8 5 BQ048 COOLING CAPACITIES (4 TON)...... 9 6 BQ060 COOLING CAPACITIES (5 TON)..... 10 7 BQ036 HEATING CAPACITIES (3 TON)...... 11 8 BQ048 HEATING CAPACITIES (4 TON)...... 11 9 BQ060 HEATING CAPACITIES (5 TON)...... 13 10 SUPPLY AIR BLOWER PERFORMANCE (3 TON DIRECT DRIVE) - SIDE DUCT APPLICATION.......................... 14 11 SUPPLY AIR BLOWER PERFORMANCE (4 TON DIRECT DRIVE) - SIDE DUCT APPLICATION.......................... 15 12 SUPPLY AIR BLOWER PERFORMANCE (5 TON BELT DRIVE) - SIDE DUCT APPLICATION.......................... 16 13 BELT DRIVE BLOWER MOTOR AND DRIVE DATA................................. 17 14 STATIC RESISTANCES.................. 17 15 ELECTRIC HEATER CFM LIMITATIONS..... 17 16 ELECTRICAL DATA - BQ036, 048, & 060..... 18 17 PHYSICAL DATA........................ 19 18 ELECTRIC HEAT CORRECTION FACTORS.. 19 19 VOLTAGE LIMITATIONS.................. 19 20 UTILITIES ENTRY....................... 23 21 MINIMUM CLEARANCES................. 23 22 BQ 4 POINT LOADS WEIGHT DISTRIBUTION (KG / LBS.)............................. 25 23 BQ 6 POINT LOADS WEIGHT DISTRIBUTION (KG / LBS.)............................. 25 24 CENTER OF GRAVITY................... 25 25 OPERATING WEIGHTS (KG / LBS.)............. 25 2 Johnson Controls Unitary Products

PRODUCT NOMENCLATURE 3-5 Ton Sunline Model Number Nomenclature B Q 048 C00 A 7 A AA 1 0 1 2 4 A Product Category B = HP, Single Pkg., R-22 Product Style A = Style A Product Identifier Q = 10.0 SEER HP Nominal Cooling Capacity 036 = 3.0 Ton 048 = 4.0 Ton 060 = 5.0 Ton Heat Type and Nominal Heat Capacity C00 = Cooling Only. Suitable for Field Installed Electric Heat Configuration Options (not required for all units) These four digits will not be assigned until a quote is requested, or an order placed. SS Drain Pan CPC Controller, DFS, APS Johnson Controller, DFS, APS Honeywell Controller, DFS, APS Novar Controller, DFS, APS Simplicity IntelliComfort Controller Simplicity IntelliComfort Controller w/modlinc 2" Pleated filters BAS Ready Economizer (2-10 V. D. C. Actuator without a Controller) Any Combination of Additional Options that Don t Have an Option Code Pre-assigned E05 = 5 KW E07 = 7 KW E10 = 10 KW E15 = 15 KW E20 = 20 KW E30 = 30 KW Electric Heat Options Product Generation 1 = First Generation 2 = Second Generation Standard Cabinet Additional Options Hinged Filter Door & Toolless Access Cabinet Airflow A = Direct Drive B = Direct Drive/Economizer D = Direct Drive/Motorized Damper N = Belt Drive P = Belt Drive/Economizer R = Belt Drive/Motorized Damper Belt Drive Not Available on 3 and 4 Ton 50 Hz Models. Voltage 7 = 380/415-3-50 AA = None AB = Phase Monitor AC = Coil Guard AD = Dirty Filter Switch AE = Phase Monitor & Coil Guard AF = Phase Monitor & Dirty Filter Switch AG = Coil Guard & Dirty Filter Switch AH = Phase Monitor, Coil Guard & Dirty Filter Switch AS = Bottom Drain Connection RC = Coil Guard & American Flag TA = Technicoat Condenser Coil TJ = Technicoat Evaporator Coil TS = Technicoat Evaporator and Condenser Coil BA = Hinged Filter Door & Toolless Access Panels BA = Hinged Filter Door & Toolless Access Panels BB = Phase Monitor, Hinged Filter Door & Toolless Access Panels BC = Coil Guard, Hinged Filter Door & Toolless Access Panels BD = Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels BE = Phase Monitor & Coil Guard, Hinged Filter Door & Toolless Access Panels BF = Phase Monitor & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels BG = Coil Guard & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels BH = Phase Monitor, Coil Guard & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18. Installation Options A = No Options Installed B = Option 1 C = Option 2 D = Options 1 & 2 E = Option 3 F = Option 4 G = Options 1 & 3 H = Options 1 & 4 J = Options 1, 2 & 3 K = Options 1, 2, & 4 L = Options 1,3 & 4 M = Options 1, 2, 3, & 4 N = Options 2 & 3 P = Options 2 & 4 Q = Options 2, 3, & 4 R = Options 3 & 4 S = Option 5 T = Options 1 & 5 U = Options 1, 3, & 5 V = Options 1, 4, & 5 W = Options 1, 3, 4, & 5 X = Options 3 & 5 Y = Options 4 & 5 Z = Options 3, 4 & 5 Options 1 = Disconnect 2 = Non-Pwr'd Conv. Outlet 3 = Smoke Detector S.A. 4 = Smoke Detector R.A. 5 = Pwr'd Conv. Outlet Johnson Controls Unitary Products 3

FEATURES All models are available with a wide variety of factorymounted options such as phase monitor, dirty filter switch, and coil guard to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with forklift holes on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All models are available with these factory mounted outdoor air damper options: Single enthalpy economizer Motorized outdoor air damper Supply air blowers are equipped with either a direct drive or a belt drive that can be adjusted to meet the exact requirements of the job. All compressors are equipped with internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch to protect all system components. Simplicity Controls - Simplicity control boards have standardized a number of features previously available only as options or by utilizing additional controls. Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0ºF outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. The Simplicity control board used in this product will effectively operate the cooling system down to 0 F when this product is applied in a comfort cooling application for people. An economizer is typically included in this type of application. When applying this product for process cooling applications (computer rooms, switchgear, etc.), please reference applications bulletin AE-011-07 or call the applications department for Unitary Products @ 1-877- UPG-SERV for guidance. Additional accessories may be needed for stable operation at temperatures below 30 F. Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti short cycle delay can be temporarily overridden with the push of a button. Fan Delays - Fan on and fan off delays are fully programmable and are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. Nuisance Trip Protection- To prevent nuisance trouble calls, the control board uses a three strikes, you re out philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the compressor. On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. All units have long lasting powder paint cabinets with 1000 hour salt spray test approval under ASTM-B117 procedures. Electric Heat Operation - All electric heat models are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive temperature by thermal limit switches. The power supply wiring can be routed into the control box through a threaded pipe connection (field supplied) in the base pan of the unit or through a knockout in the wiring panel on the side of the unit. BAS Controls - York s Sunline series units offer factory mounted BAS controls such as Novar, Honeywell, Johnson, and CPC. 4 Johnson Controls Unitary Products

FIGURE 1 - UNIT CUTAWAY FACTORY-INSTALLED OPTIONS SINGLE INPUT ELECTRONIC ENTHALPY ECONO- MIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rainhood is painted to match the basic unit and must be field-assembled before installing. MOTORIZED OUTDOOR AIR INTAKE DAMPER - Includes a slide-in / plug-in damper assembly with a 2-position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. PHENOLIC COATED EVAPORATOR AND CON- DENSER COILS - Special coating process that utilizes Technicoat 10-1 TM processes. Coating is applied by total immersion of the complete coil for maximum protection. ELECTRIC HEATERS wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. FILTER OPTIONS - Standard units are shipped with 25mm (1in) throw-away filters installed. 50mm (2in) pleated filters are offered as a factory installed option. CONVENIENCE OUTLET - This 110 volt outlet can be powered by the unit with a stepdown transformer or the unit may be ordered with a non-powered convenience outlet that can be wired in the field. DISCONNECT SWITCH - For gas heat units and cooling units with electric heat, a HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only. BAS - See Additional Options section in the product nomenclature. SMOKE DETECTORS - (supply air & return air) The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. m Factory installed Smoke Detectors in the Return Air, may be subjected to freezing temperatures during off times due to Out Side Air infiltration. These Smoke Detectors have an operational limit of 32 F to 131 F. Smoke Detectors installed in areas that could be out side those limitations will have to be moved to prevent having false alarms. Johnson Controls Unitary Products 5

COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-ofphase condition. DIRTY FILTER SWITCH - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. HINGED FILTER DOOR/ TOOLLESS BLOWER AND ACCESS PANELS (not hinged) - This option allows for easy access and maintenance. NOTE:Knobs are shipped inside the unit to prevent shipping damage. These must be field installed for tool-less operation. FIELD-INSTALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONO- MIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rainhood is painted to match the basic unit and must be field-assembled before installing. MOTORIZED OUTDOOR AIR INTAKE DAMPER - Includes a slide-in / plug-in damper assembly with a 2- position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. ELECTRIC HEATERS wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. ROOF CURBS - Eight and fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly. Roof curbs are designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. POWER EXHAUST - Our single input economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation. The power exhaust option can only be used on bottom duct configurations. BAROMETRIC RELIEF DAMPER - This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. ENTHALPY ACCESSORY CONTROL KIT - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. BURGLAR BARS - Mount in the supply and return openings to prevent entry into the duct work. CO 2 SENSOR - Senses CO 2 levels and automatically overrides the economizer when levels rise above the present limits. COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-ofphase condition. 6 Johnson Controls Unitary Products

TABLE 1: SOUND POWER RATING 1 UNIT SIZE CFM ESP BLOWER SOUND POWER (db 10-12 Watts) Octave Band Centerline Frequency (Hz) IWG SPEED KW 63 125 250 500 1,000 2,000 4,000 8,000 SWL db(a) db(a) @ 10Ft. 2 036 1,200 0.6 LOW 0.60 84 84 74 67 69 62 57 52 74 41 048 1,600 0.55 HIGH 0.80 85 85 75 68 70 63 58 53 75 42 060 2,000 0.45 HIGH 1.00 86 86 76 69 71 64 59 54 76 43 1. These values have been accessed using a model of sound propagation from a point source into the hemispheric\free field. The dba values provided are to be used for reference only. Calculation of dba values cover matters of system design and the fan manufacture has no way of knowing the details of each system. This constitutes and expectation to any specification or guarantee requiring a dba value or sound data in any other form than sound power level ratings. 2. At a distance of 10 feet from the blower. TABLE 2: CAPACITY RATING (COOLING) MODEL INDOOR DB/WB OUTDOOR DB/WB TOTAL OUTPUT TOTAL OUTPUT C F C F kw MBH kw 036 29/19 84/66 46/24 85/75 8.34 28.5 4.37 1.9 048 29/19 84/66 46/24 85/75 11.7 39.9 5.85 2.0 060 29/19 84/66 46/24 85/75 13.9 47.5 7.7 1.8 1. COP = Coefficient of Performance - Total output kw divided by the total input kw. COP 1 TABLE 3: CAPACITY RATING (HEATING) MODEL 036 048 060 RATING POINT INDOOR DB/WB OUTDOOR DB/WB TOTAL OUTPUT TOTAL OUTPUT C F C F kw MBH kw High 20/12 68/54 7/6 45/43 9.7 33 3.34 2.9 Low 20/12 68/54 2/1 36/34 7.9 27 3.0 2.6 High 20/12 68/54 7/6 45/43 12.7 43.4 4.55 2.79 Low 20/12 68/54 2/1 36/34 10.4 35.5 4.15 2.51 High 20/12 68/54 7/6 45/53 16.3 55.6 5.6 2.91 Low 20/12 68/54 2/1 36/34 13.5 46.1 5.20 2.60 1. COP = Coefficient of Performance - Total output kw divided by the total input kw. COP 1 Johnson Controls Unitary Products 7

TABLE 4: BQ036 COOLING CAPACITIES (3 TON) AIR ON EVAPORATOR COIL M 3 /S WB ºC TOTAL CAP. 1 KW POWER INPUT 2 KW KW TEMPERATURE OF AIR ON OUTDOOR COIL 27ºC 35ºC 46ºC SENSIBLE CAPACITY 1, KW SENSIBLE CAPACITY 1, MBH SENSIBLE CAPACITY 1, MBH ENTERING DRY BULB, ºC CAP 1. INPUT 2 ENTERING DRY BULB ºC CAP 1. INPUT 2 ENTERING DRY BULB, ºC 31 28 25 22 KW KW 31 28 25 22 KW KW 31 28 25 22 23 13.2 2.9 8.6 6.6 6.2 -- 11.4 3.5 8.2 6.2 5.3 -- 10.3 3.9 7.9 5.9 4.7 -- 20 14.9 2.8 11.3 8.3 7.2 5.1 10.3 3.4 10.0 7.9 6.7 4.7 9.1 3.8 9.1 7.6 6.4 4.4 0.59 17 11.0 2.7 11.0 11.0 9.8 7.8 9.7 3.3 9.7 9.7 8.5 6.4 8.8 3.7 8.8 8.8 7.6 5.6 14 11.0 2.7 11.0 11.0 9.8 7.8 9.7 3.3 9.7 9.7 8.5 6.4 8.8 3.7 8.8 8.8 7.6 5.6 23 12.6 2.7 8.2 6.0 5.1 -- 10.8 3.4 7.3 5.6 4.7 -- 9.7 3.9 6.7 5.3 4.4 -- 20 11.7 2.7 9.2 7.5 6.6 4.8 10.0 3.3 8.8 7.0 6.2 4.4 8.8 3.7 8.5 6.7 5.9 4.1 0.47 17 10.7 2.6 10.7 9.8 8.5 6.7 9.4 3.2 9.4 8.5 7.6 5.9 8.5 3.6 8.5 7.6 7.0 5.3 14 10.7 2.6 10.7 9.8 8.5 6.7 9.4 3.2 9.4 8.5 7.6 5.9 8.5 3.6 8.5 7.6 7.0 5.3 23 11.9 2.8 6.6 6.2 5.1 -- 10.5 3.4 6.2 5.3 4.7 -- 9.7 3.8 5.9 4.7 4.4 -- 20 11.0 2.7 8.1 6.9 7.0 5.4 9.7 3.3 7.6 6.4 6.2 5.0 8.8 3.7 7.3 6.2 5.6 4.7 0.41 17 10.0 2.6 9.8 8.8 8.2 7.3 9.1 3.2 8.5 7.9 7.3 6.4 8.5 3.6 7.6 7.3 6.7 5.9 14 10.0 2.6 9.8 8.8 8.2 7.3 9.1 3.2 8.5 7.9 7.3 6.4 8.5 3.6 7.6 7.3 6.7 5.9 MBH TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON EVAPORATOR 80ºF 95ºF 115ºF COIL SENSIBLE CAPACITY 1, KW SENSIBLE CAPACITY 1, MBH SENSIBLE CAPACITY 1, MBH CAP. 1 INPUT 2 ENTERING DRY BULB, ºF CAP 1. INPUT 2 ENTERING DRY BULB ºF CAP 1. INPUT 2 ENTERING DRY BULB, ºF CFM WB KW KW KW KW KW KW 88 80 77 72 88 80 77 72 ºF 88 80 77 72 73 45.0 2.9 29.5 22.5 21.0 -- 39.0 3.5 28.0 21.0 18.0 -- 35.0 3.9 27.0 20.0 16.0 -- 66 41.0 2.8 38.5 28.5 24.5 17.5 35.0 3.4 34.0 27.0 23.0 16.0 31.0 3.8 31.0 26.0 22.0 15.0 1250 62 37.5 2.7 37.5 37.5 33.5 26.5 33.0 3.3 33.0 33.0 29.0 22.0 30.0 3.7 30.0 30.0 26.0 19.0 57 37.5 2.7 37.5 37.5 33.5 26.5 33.0 3.3 33.0 33.0 29.0 22.0 30.0 3.7 30.0 30.0 26.0 19.0 73 43.0 2.7 28.0 20.5 17.5 -- 37.0 3.4 25.0 19.0 16.0 -- 33.0 3.9 23.0 18.0 15.0 -- 66 40.0 2.7 31.5 25.5 22.5 16.5 34.0 3.3 30.0 24.0 21.0 15.0 30.0 3.7 29.0 23.0 20.0 14.0 1000 62 36.5 2.6 36.5 33.5 29.0 23.0 32.0 3.2 32.0 29.0 26.0 20.0 29.0 3.6 29.0 26.0 24.0 18.0 57 36.5 2.6 36.5 33.5 29.0 23.0 32.0 3.2 32.0 29.0 26.0 20.0 29.0 3.6 29.0 26.0 24.0 18.0 73 40.5 2.8 22.5 21.0 17.5 -- 36.0 3.4 21.0 18.0 16.0 -- 33.0 3.8 20.0 16.0 15.0 -- 66 37.5 2.7 27.5 23.5 24.0 18.5 33.0 3.3 26.0 22.0 21.0 17.0 30.0 3.7 25.0 21.0 19.0 16.0 875 62 34.0 2.6 33.5 30.0 28.0 25.0 31.0 3.2 29.0 27.0 25.0 22.0 29.0 3.6 26.0 25.0 23.0 20.0 57 34.0 2.6 33.5 30.0 28.0 25.0 31.0 3.2 29.0 27.0 25.0 22.0 29.0 3.6 26.0 25.0 23.0 20.0 1. These capacities are gross ratings. For net capacity, determine the kw of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.46 kw. Refer to the SUPPLY AIR BLOWER PERFORMANCE table for the kw of the supply air blower motor. 8 Johnson Controls Unitary Products

TABLE 5: BQ048 COOLING CAPACITIES (4 TON) AIR ON EVAPORATOR COIL M 3 /S WB ºC TOTAL CAP. 1 KW POWER INPUT 2 KW KW TEMPERATURE OF AIR ON OUTDOOR COIL 27ºC 35ºC 46ºC SENSIBLE CAPACITY 1, KW SENSIBLE CAPACITY 1, MBH SENSIBLE CAPACITY 1, MBH ENTERING DRY BULB, ºC CAP 1. INPUT 2 ENTERING DRY BULB ºC CAP 1. INPUT 2 ENTERING DRY BULB, ºC 31 28 25 22 KW KW 31 28 25 22 KW KW 31 28 25 22 23 19.8 3.9 11.4 9.0 7.8 -- 18.4 4.4 10.6 8.4 7.3 -- 16.5 5.1 9.5 7.5 6.5 -- 20 17.3 3.9 16.9 13.3 11.6 8.9 16.0 4.4 15.5 12.3 10.6 8.2 14.0 5.1 13.6 10.6 9.4 7.2 0.95 17 16.0 3.9 16.0 14.1 12.2 9.4 14.6 4.3 14.6 12.9 11.2 8.6 12.7 5.0 12.7 11.2 9.7 7.5 14 14.1 3.8 14.1 13.8 12.6 11.4 12.7 4.3 12.7 12.4 11.3 9.7 10.8 5.0 10.8 10.6 10.0 8.2 23 17.6 3.9 10.1 8.0 6.9 -- 16.3 4.4 9.4 7.4 6.5 -- 14.6 5.1 8.4 6.7 5.8 -- 20 15.3 3.9 15.0 11.9 10.3 7.9 14.1 4.4 13.8 10.9 9.5 7.3 12.4 5.1 12.1 9.6 8.3 6.4 0.75 17 14.2 3.8 14.2 12.5 10.9 8.4 13.0 4.3 13.0 11.4 9.9 7.7 11.3 5.0 11.3 9.9 8.6 6.7 14 12.5 3.8 12.5 12.2 11.2 10.1 11.3 4.3 11.3 11.0 10.0 8.6 9.6 5.0 9.6 9.4 8.9 7.3 23 15.0 3.9 8.7 6.8 5.9 -- 14.0 4.4 8.0 6.4 5.5 -- 12.5 5.1 7.2 5.7 5.0 -- 20 13.1 3.9 12.8 10.1 8.8 6.8 12.1 4.3 11.8 9.3 8.1 6.3 10.6 5.0 10.4 8.2 7.1 5.5 0.55 17 12.2 3.8 12.2 10.7 9.3 7.2 11.1 4.3 11.1 9.8 8.5 6.6 9.7 5.0 9.7 8.5 7.4 5.7 14 10.7 3.8 10.7 10.5 9.6 8.6 9.7 4.3 9.7 9.5 8.6 7.4 8.2 5.0 8.2 8.0 7.6 6.3 MBH TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON EVAPORATOR 80ºF 95ºF 115ºF COIL SENSIBLE CAPACITY 1, KW SENSIBLE CAPACITY 1, MBH SENSIBLE CAPACITY 1, MBH CAP. 1 INPUT 2 ENTERING DRY BULB, ºF CAP 1. INPUT 2 ENTERING DRY BULB ºF CAP 1. INPUT 2 ENTERING DRY BULB, ºF CFM WB KW KW KW KW KW KW 88 80 77 72 88 80 77 72 ºF 88 80 77 72 73 68.0 3.9 39.0 31.0 27.0 -- 63.0 4.4 36.0 29.0 25.0 -- 56.0 5.1 32.0 26.0 22.0 -- 66 59.0 3.9 58.0 45.0 40.0 30.0 55.0 4.4 53.0 42.0 36.0 28.0 48.0 5.1 46.0 36.0 32.0 25.0 2000 62 55.0 3.9 55.0 48.0 42.0 32.0 50.0 4.3 50.0 44.0 38.0 29.0 43.0 5.0 43.0 38.0 33.0 26.0 57 48.0 3.8 48.0 47.0 43.0 39.0 43.0 4.3 43.0 42.0 39.0 33.0 37.0 5.0 37.0 36.0 34.0 28.0 73 60.0 3.9 35.0 27.0 24.0 -- 56.0 4.4 32.0 25.0 22.0 -- 50.0 5.1 29.0 23.0 20.0 -- 66 52.0 3.9 51.0 41.0 35.0 27.0 48.0 4.4 47.0 37.0 32.0 25.0 42.0 5.1 41.0 33.0 28.0 22.0 1600 62 48.0 3.8 48.0 43.0 37.0 29.0 44.0 4.3 44.0 39.0 34.0 26.0 39.0 5.0 39.0 34.0 33.0 23.0 57 43.0 3.8 43.0 42.0 38.0 34.0 39.0 4.3 39.0 38.0 34.0 29.0 33.0 5.0 33.0 32.0 30.0 25.0 73 51.0 3.9 30.0 23.0 20.0 -- 48.0 4.4 27.0 22.0 19.0 -- 43.0 5.1 25.0 19.0 17.0 -- 66 45.0 3.9 44.0 34.0 30.0 23.0 41.0 4.3 40.0 32.0 28.0 22.0 36.0 5.0 36.0 28.0 24.0 19.0 1200 62 42.0 3.8 42.0 37.0 32.0 25.0 38.0 4.3 38.0 33.0 29.0 23.0 33.0 5.0 33.0 29.0 25.0 19.0 57 37.0 3.8 37.0 36.0 33.0 29.0 33.0 4.3 33.0 32.0 29.0 25.0 28.0 5.0 28.0 27.0 26.0 22.0 1. These capacities are gross ratings. For net capacity, determine the kw of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.46 kw. Refer to the SUPPLY AIR BLOWER PERFORMANCE table for the kw of the supply air blower motor. Johnson Controls Unitary Products 9

TABLE 6: BQ060 COOLING CAPACITIES (5 TON) AIR ON EVAPORATOR COIL M 3 /S WB ºC TOTAL CAP. 1 KW POWER INPUT 2 KW KW TEMPERATURE OF AIR ON OUTDOOR COIL 27ºC 35ºC 46ºC SENSIBLE CAPACITY 1, KW SENSIBLE CAPACITY 1, MBH SENSIBLE CAPACITY 1, MBH ENTERING DRY BULB, ºC CAP 1. INPUT 2 ENTERING DRY BULB ºC CAP 1. INPUT 2 ENTERING DRY BULB, ºC 31 28 25 22 KW KW 31 28 25 22 KW KW 31 28 25 22 23 24.7 4.7 14.2 11.2 9.7 -- 22.7 5.7 13.0 10.3 9.0 -- 19.9 7.0 11.4 9.1 7.9 -- 20 21.2 4.7 20.7 16.4 14.2 11.0 19.2 5.7 18.8 14.9 12.9 10.0 16.5 7.0 16.1 12.7 11.1 8.5 1.15 17 19.5 4.6 19.5 17.2 14.9 11.5 17.5 5.7 17.5 15.4 13.4 10.3 14.8 6.9 14.8 13.0 11.3 8.7 14 16.9 4.6 16.9 16.5 15.4 12.5 14.9 5.6 14.9 14.6 14.3 12.1 12.2 6.9 12.2 11.9 11.4 9.1 23 22.4 4.7 12.9 10.2 8.9 -- 20.6 5.7 11.8 9.4 8.1 -- 18.1 7.0 10.4 8.2 7.1 -- 20 19.3 4.6 18.8 14.9 12.9 10.0 17.5 5.7 17.1 13.5 11.7 9.0 15.0 7.0 14.6 11.6 10.0 7.8 0.95 17 17.7 4.6 17.7 15.6 13.5 10.5 15.9 5.6 15.9 14.0 12.2 9.4 13.4 6.9 13.4 11.8 10.2 7.9 14 15.4 4.6 15.4 15.0 14.0 11.4 13.6 5.6 13.6 13.3 13.0 11.0 11.1 6.9 11.1 10.8 10.4 8.3 23 19.9 4.7 11.5 9.1 7.9 -- 18.3 5.7 10.5 8.3 7.2 -- 16.1 7.0 9.2 7.3 6.4 -- 20 17.1 4.6 16.7 13.2 11.5 8.9 15.5 5.7 15.2 12.0 10.4 8.0 13.3 7.0 13.0 10.3 8.9 6.9 0.75 17 15.8 4.6 15.8 13.9 12.0 9.3 14.1 5.6 14.1 12.4 10.8 8.3 11.9 6.9 11.9 10.5 9.1 7.0 14 13.7 4.6 13.7 13.4 12.4 10.1 12.1 5.6 12.1 11.8 11.6 9.8 9.8 6.9 9.8 9.6 9.2 7.4 MBH TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON EVAPORATOR 80ºF 95ºF 115ºF COIL SENSIBLE CAPACITY 1, KW SENSIBLE CAPACITY 1, MBH SENSIBLE CAPACITY 1, MBH CAP. 1 INPUT 2 ENTERING DRY BULB, ºF CAP 1. INPUT 2 ENTERING DRY BULB ºF CAP 1. INPUT 2 ENTERING DRY BULB, ºF CFM WB KW KW KW KW KW KW 88 80 77 72 88 80 77 72 ºF 88 80 77 72 73 84.0 4.7 48.0 38.0 33.0 -- 77.0 5.7 44.0 35.0 31.0 -- 68.0 7.0 39.0 31.0 27.0 -- 66 72.0 4.7 71.0 56.0 48.0 38.0 66.0 5.7 64.0 51.0 44.0 34.0 56.0 7.0 55.0 43.0 38.0 29.0 2400 62 67.0 4.6 67.0 59.0 51.0 39.0 60.0 5.7 60.0 53.0 46.0 35.0 51.0 6.9 51.0 44.0 39.0 30.0 57 58.0 4.6 58.0 56.0 53.0 43.0 51.0 5.6 51.0 50.0 49.0 41.0 42.0 6.9 42.0 41.0 39.0 31.0 73 76.0 4.7 44.0 35.0 30.0 -- 70.0 5.7 40.0 32.0 28.0 -- 62.0 7.0 36.0 28.0 24.0 -- 66 66.0 4.6 64.0 51.0 44.0 34.0 60.0 5.7 58.0 46.0 40.0 31.0 51.0 7.0 50.0 40.0 34.0 27.0 2000 62 60.0 4.6 60.0 53.0 46.0 36.0 54.0 5.6 54.0 48.0 42.0 32.0 46.0 6.9 46.0 40.0 35.0 27.0 57 53.0 4.6 53.0 51.0 48.0 39.0 46.0 5.6 46.0 45.0 44.0 38.0 38.0 6.9 38.0 35.0 36.0 30.0 73 68.0 4.7 39.0 31.0 27.0 -- 62.0 5.7 36.0 28.0 25.0 -- 55.0 7.0 31.0 25.0 22.0 -- 66 58.0 4.6 57.0 45.0 39.0 30.0 53.0 5.7 52.0 41.0 36.0 27.0 45.0 7.0 44.0 35.0 30.0 24.0 1600 62 54.0 4.6 54.0 47.0 41.0 32.0 48.0 5.6 48.0 42.0 37.0 28.0 40.0 6.9 41.0 36.0 31.0 24.0 57 47.0 4.6 47.0 46.0 42.0 34.0 41.0 5.6 41.0 40.0 40.0 33.0 33.0 6.9 33.0 33.0 31.0 25.0 1. These capacities are gross ratings. For net capacity, determine the kw of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.46 kw. Refer to the SUPPLY AIR BLOWER PERFORMANCE table for the kw of the supply air blower motor. 10 Johnson Controls Unitary Products

TABLE 7: BQ036 HEATING CAPACITIES (3 TON) M 3 /S 0.59 0.47 0.35 RETURN AIR ºC 13 21 27 13 21 27 13 21 27 OUTPUT, kw IMPUT, kw kw OUTDOOR AIR TEMPEATURE ºC (72% RH) -23-18 -12-7 -1 4 10 16 OUTPUT 2.5 3.3 4.2 5.2 6.3 7.6 9.0 10.5 INPUT 2.7 2.7 2.7 2.8 2.9 3.1 3.3 3.6 OUTPUT 2.4 3.2 4.0 5.0 6.1 7.3 8.6 10.1 INPUT 2.9 2.9 2.9 3.0 3.1 3.3 3.5 3.8 OUTPUT 2.2 2.9 3.7 4.6 5.6 6.7 8.0 9.3 INPUT 3.0 3.0 3.1 3.1 3.3 3.5 3.7 4.0 OUTPUT 2.5 3.2 4.0 5.0 6.1 7.4 8.7 10.2 INPUT 2.7 2.7 2.8 2.9 3.0 3.2 3.4 3.6 OUTPUT 2.4 3.1 3.9 4.8 5.9 7.1 8.4 9.8 INPUT 2.8 2.8 2.9 3.0 3.1 3.3 3.5 3.8 OUTPUT 2.2 2.8 3.6 4.5 5.4 6.5 7.7 9.0 INPUT 2.9 2.9 3.0 3.1 3.3 3.5 3.7 4.0 OUTPUT 2.3 3.0 3.8 4.7 5.8 6.9 8.2 9.6 INPUT 2.5 2.7 2.6 2.7 2.8 3.0 3.2 3.4 OUTPUT 2.2 2.9 3.7 4.6 5.6 6.7 7.9 9.2 INPUT 2.6 2.6 2.7 2.8 2.9 3.1 3.3 3.6 OUTPUT 2.0 2.6 3.4 4.2 5.1 6.2 7.3 8.5 INPUT 2.8 2.8 2.8 2.9 3.1 3.3 3.5 3.8 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (kw) CFM 1250 1000 750 RETURN AIR ºF 55 70 80 55 70 80 55 70 80 MBH OUTPUT, MBH OUTDOOR AIR TEMPEATURE ºF (72% RH) INPUT, kw -10 0 10 20 30 40 50 60 OUTPUT 8.6 11.2 14.3 17.7 21.6 25.9 30.7 35.8 INPUT 2.7 2.7 2.7 2.8 2.9 3.1 3.3 3.6 OUTPUT 8.3 10.9 13.7 17.1 20.8 25.0 29.5 34.5 INPUT 2.9 2.9 2.9 3.0 3.1 3.3 3.5 3.8 OUTPUT 7.6 10.0 12.6 15.7 19.2 23.0 27.2 31.7 INPUT 3.0 3.0 3.1 3.1 3.3 3.5 3.7 4.0 OUTPUT 8.4 10.9 13.8 17.2 20.9 25.1 29.7 34.7 INPUT 2.7 2.7 2.8 2.9 3.0 3.2 3.4 3.6 OUTPUT 8.1 10.5 13.3 16.5 20.2 24.2 28.6 33.4 INPUT 2.8 2.8 2.9 3.0 3.1 3.3 3.5 3.8 OUTPUT 7.4 9.6 12.2 15.2 18.5 22.2 26.3 30.7 INPUT 2.9 2.9 3.0 3.1 3.3 3.5 3.7 4.0 OUTPUT 7.8 10.2 13.0 16.2 19.8 23.7 28.1 32.8 INPUT 2.5 2.7 2.6 2.7 2.8 3.0 3.2 3.4 OUTPUT 7.5 9.8 12.5 15.6 19.0 22.8 27.0 31.5 INPUT 2.6 2.6 2.7 2.8 2.9 3.1 3.3 3.6 OUTPUT 6.9 9.0 11.5 14.3 17.5 21.0 24.8 29.0 INPUT 2.8 2.8 2.8 2.9 3.1 3.3 3.5 3.8 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (MBH = 3.415 x kw) Johnson Controls Unitary Products 11

TABLE 8: BQ048 HEATING CAPACITIES (4 TON) M 3 /S 0.95 0.75 0.55 RETURN AIR ºC 13 21 27 13 21 27 13 21 27 OUTPUT, kw INPUT, kw kw OUTDOOR AIR TEMPEATURE ºC (72% RH) -23-18 -12-7 -1 4 10 16 OUTPUT 3.6 5.1 6.6 8.3 10.6 13.0 15.8 18.0 INPUT 3.4 3.5 3.6 3.6 3.8 4.0 4.6 5.2 OUTPUT 3.5 4.9 6.3 7.9 10.2 12.4 15.1 17.3 INPUT 3.5 3.6 3.8 3.8 4.0 4.2 4.8 5.4 OUTPUT 3.2 4.5 5.8 7.3 9.4 11.5 13.9 16.0 INPUT 3.6 3.7 4.0 4.0 4.1 4.4 5.0 5.7 OUTPUT 3.5 5.0 6.4 8.1 10.1 12.4 15.0 17.2 INPUT 3.3 3.4 3.5 3.6 3.6 3.8 4.4 5.0 OUTPUT 3.4 4.8 6.2 7.8 9.7 11.9 14.4 16.5 INPUT 3.4 3.5 3.6 3.7 3.8 4.0 4.6 5.2 OUTPUT 3.1 4.4 5.7 7.2 8.9 11.0 13.3 15.2 INPUT 3.5 3.6 3.8 3.9 4.0 4.2 4.8 5.4 OUTPUT 3.2 4.5 5.8 7.9 9.3 11.4 13.8 15.8 INPUT 3.1 3.2 3.3 3.4 3.5 3.7 4.2 4.8 OUTPUT 3.1 4.3 5.6 7.0 8.9 11.0 13.2 15.1 INPUT 3.2 3.3 3.4 3.5 3.6 3.8 4.4 5.0 OUTPUT 2.8 4.0 5.2 6.4 8.2 10.1 12.2 13.9 INPUT 3.3 3.4 3.5 3.6 3.8 4.0 4.6 5.2 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (kw) CFM 2000 1600 1200 RETURN AIR ºF 55 70 80 55 70 80 55 70 80 MBH OUTPUT, MBH OUTDOOR AIR TEMPEATURE ºF (72% RH) INPUT, kw -10 0 10 20 30 40 50 60 OUTPUT 12.3 17.3 22.5 28.2 36.3 44.5 53.8 61.6 INPUT 3.4 3.5 3.6 3.6 3.8 4.0 4.6 5.2 OUTPUT 11.8 16.6 21.6 27.1 34.9 42.8 51.7 59.2 INPUT 3.5 3.6 3.8 3.8 4.0 4.2 4.8 5.4 OUTPUT 10.9 15.3 19.9 24.9 32.1 39.4 47.6 54.5 INPUT 3.6 3.7 4.0 4.0 4.1 4.4 5.0 5.7 OUTPUT 12.1 17.0 22.0 27.7 34.5 42.3 51.2 58.6 INPUT 3.3 3.4 3.5 3.6 3.6 3.8 4.4 5.0 OUTPUT 11.6 16.3 21.2 26.6 33.2 40.7 49.2 56.3 INPUT 3.4 3.5 3.6 3.7 3.8 4.0 4.6 5.2 OUTPUT 10.7 15.0 19.5 24.5 30.5 37.4 45.3 51.8 INPUT 3.5 3.6 3.8 3.9 4.0 4.2 4.8 5.4 OUTPUT 10.9 15.3 19.9 24.9 31.7 38.9 47.0 53.8 INPUT 3.1 3.2 3.3 3.4 3.5 3.7 4.2 4.8 OUTPUT 10.5 14.7 19.1 24.0 30.5 37.4 45.2 51.7 INPUT 3.2 3.3 3.4 3.5 3.6 3.8 4.4 5.0 OUTPUT 9.6 13.5 17.6 22.0 28.1 34.4 41.6 47.6 INPUT 3.3 3.4 3.5 3.6 3.8 4.0 4.6 5.2 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (MBH = 3.415 x kw) 12 Johnson Controls Unitary Products

TABLE 9: BQ060 HEATING CAPACITIES (5 TON) M 3 /S 1.18 0.95 0.71 RETURN AIR ºC 13 21 27 13 21 27 13 21 27 OUTPUT, kw INPUT, kw kw OUTDOOR AIR TEMPEATURE ºC (72% RH) -23-18 -12-7 -1 4 10 16 OUTPUT 5.3 7.2 9.1 11.2 13.4 16.2 18.9 22.1 INPUT 5.0 5.1 5.2 5.3 5.3 5.6 5.9 6.5 OUTPUT 5.1 6.9 8.8 10.8 12.9 15.6 18.2 21.3 INPUT 5.2 5.3 5.4 5.5 5.6 5.9 6.2 6.8 OUTPUT 4.7 6.4 8.1 10.0 11.8 14.4 16.8 19.6 INPUT 5.4 5.6 5.7 5.8 5.9 6.0 6.5 7.2 OUTPUT 5.3 7.1 9.0 11.2 13.2 16.0 18.7 21.9 INPUT 4.7 4.8 4.9 5.0 5.3 5.5 5.8 6.4 OUTPUT 5.1 6.9 8.7 10.7 12.7 15.4 18.0 21.0 INPUT 4.9 5.0 5.1 5.2 5.5 5.8 6.1 6.7 OUTPUT 4.7 6.3 8.0 9.9 11.7 14.2 16.5 19.4 INPUT 5.1 5.3 5.4 5.5 5.8 6.1 6.4 7.0 OUTPUT 4.7 6.4 8.1 10.0 12.1 14.7 17.2 20.1 INPUT 4.5 4.6 4.7 4.8 5.0 5.3 5.5 6.1 OUTPUT 4.6 6.2 7.8 9.7 11.7 14.1 16.5 19.3 INPUT 4.7 4.8 4.9 5.0 5.2 5.5 5.8 6.4 OUTPUT 4.2 5.7 7.2 8.9 10.7 13.0 15.2 17.8 INPUT 4.9 5.0 5.1 5.2 5.5 5.8 6.1 6.7 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (kw) CFM 2500 2000 1500 RETURN AIR ºF 55 70 80 55 70 80 55 70 80 MBH OUTPUT, MBH OUTDOOR AIR TEMPEATURE ºF (72% RH) INPUT, kw -10 0 10 20 30 40 50 60 OUTPUT 18.2 24.7 31.1 38.4 45.6 55.4 64.7 75.6 INPUT 5.0 5.1 5.2 5.3 5.3 5.6 5.9 6.5 OUTPUT 17.5 23.7 29.9 37.0 43.9 53.3 62.2 72.7 INPUT 5.2 5.3 5.4 5.5 5.6 5.9 6.2 6.8 OUTPUT 16.1 21.8 27.5 34.0 40.4 49.0 57.2 66.9 INPUT 5.4 5.6 5.7 5.8 5.9 6.0 6.5 7.2 OUTPUT 18.0 24.4 30.8 38.1 45.0 54.7 63.9 74.7 INPUT 4.7 4.8 4.9 5.0 5.3 5.5 5.8 6.4 OUTPUT 17.3 23.5 29.6 36.6 43.3 52.6 61.4 71.8 INPUT 4.9 5.0 5.1 5.2 5.5 5.8 6.1 6.7 OUTPUT 15.9 21.6 27.2 33.7 39.8 48.4 56.5 66.1 INPUT 5.1 5.3 5.4 5.5 5.8 6.1 6.4 7.0 OUTPUT 16.2 22.0 27.8 34.3 41.4 50.2 58.7 68.6 INPUT 4.5 4.6 4.7 4.8 5.0 5.3 5.5 6.1 OUTPUT 15.6 21.2 26.7 33.0 39.8 48.3 56.4 66.0 INPUT 4.7 4.8 4.9 5.0 5.2 5.5 5.8 6.4 OUTPUT 14.4 19.5 24.6 30.4 36.6 44.5 51.9 60.7 INPUT 4.9 5.0 5.1 5.2 5.5 5.8 6.1 6.7 THE MBH AND KW VALUES DO NOT INCLUDE THE SUPPLY AIR BLOWER MOTOR. FOR NET CAPACITY, ADD THE SUPPLY AIR BLOWER MOTOR HEAT (MBH = 3.415 x kw) Johnson Controls Unitary Products 13

TABLE 10: SUPPLY AIR BLOWER PERFORMANCE (3 TON DIRECT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 3 1 UNIT TONNAGE 3 1 MOTOR SPEED M 3 /S WATTS M 3 /S WATTS M 3 /S WATTS M 3 /S WATTS M 3 /S WATTS HI - - - - - - 0.81 825 0.78 795 MED 0.78 850 0.77 820 0.75 780 0.73 750 0.70 720 LOW 0.69 750 0.69 725 0.66 700 0.64 675 0.62 650 MOTOR SPEED M 3 /S AVAILABLE EXTERNAL STATIC PRESSURE-Pa* 50 74 99 124 174 AVAILABLE EXTERNAL STATIC PRESSURE-Pa* 198 223 248 M 3 /S WATTS M 3 /S WATTS M 3 /S WATTS M 3 /S WATTS HI 0.75 765 0.72 735 0.70 700 0.65 670 MED 0.68 690 0.66 665 0.64 650 0.60 610 LOW 0.60 625 0.59 610 0.57 600 0.53 560 149 UNIT TONNAGE 3 1 MOTOR SPEED CFM AVAILABLE EXTERNAL STATIC PRESSURE-IWG* 0.20 0.30 0.40 0.50 0.60 CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS HI - - - - - - 1720 825 1665 795 MED 1660 850 1630 820 1590 780 1550 750 1500 720 LOW 1470 750 1440 725 1410 700 1370 675 1330 650 UNIT TONNAGE MOTOR SPEED AVAILABLE EXTERNAL STATIC PRESSURE-IWG* 0.70 0.80 0.90 1.00 CFM WATTS CFM WATTS CFM WATTS CFM WATTS HI 1600 765 1540 735 1490 700 1380 670 3 1 MED 1450 690 1400 665 1360 650 1270 610 LOW 1290 625 1250 610 1220 600 1130 560 1. Side Duct application (380/415 Volts) *. Includes allowances for a wet evaporator coil, 25mm [1 in] filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance values on applications other than units with side duct airflows. 14 Johnson Controls Unitary Products

TABLE 11: SUPPLY AIR BLOWER PERFORMANCE (4 TON DIRECT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 4 1 UNIT TONNAGE 4 1 MOTOR SPEED M 3 /S WATTS M 3 /S WATTS M 3 /S WATTS M 3 /S WATTS M 3 /S WATTS HI - - - - 0.94 1010 0.92 975 0.90 945 MED 0.85 910 0.84 880 0.82 850 0.80 825 0.79 800 LOW 0.77 810 0.76 780 0.75 760 0.73 740 0.73 730 MOTOR SPEED M 3 /S AVAILABLE EXTERNAL STATIC PRESSURE-Pa* 50 74 99 124 174 AVAILABLE EXTERNAL STATIC PRESSURE-Pa* 198 223 248 M 3 /S WATTS M 3 /S WATTS M 3 /S WATTS M 3 /S WATTS HI 0.87 910 0.93 825 0.78 825 0.72 775 MED 0.76 775 0.74 740 0.70 700 0.66 660 LOW 0.71 715 0.69 690 0.66 660 0.61 615 149 UNIT TONNAGE 4 1 MOTOR SPEED CFM AVAILABLE EXTERNAL STATIC PRESSURE-IWG* 0.20 0.30 0.40 0.50 0.60 CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS HI - - - - 2000 1010 1950 975 1905 945 MED 1810 910 1780 880 1740 850 1700 825 1665 800 LOW 1635 810 1610 780 1580 760 1555 740 1540 730 UNIT TONNAGE MOTOR SPEED AVAILABLE EXTERNAL STATIC PRESSURE-IWG* 0.70 0.80 0.90 1.00 CFM WATTS CFM WATTS CFM WATTS CFM WATTS HI 1840 910 1770 825 1660 825 1530 775 4 1 MED 1620 775 1560 740 1480 700 1390 660 LOW 1510 715 1460 690 1400 660 1300 615 1. Side Duct application (380/415 Volts) *. Includes allowances for a wet evaporator coil, 25mm [1 in] filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for resistance values on applications other than units with side duct airflows. Johnson Controls Unitary Products 15

TABLE 12: SUPPLY AIR BLOWER PERFORMANCE (5 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 5 1 UNIT TONNAGE 5 1 UNIT TONNAGE 5 1 UNIT TONNAGE 5 1 AIR FLOW AVAILABLE EXTERNAL STATIC PRESSURE-Pa* 50 74 99 124 149 174 198 M 3 /S RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 1.18 1059 1560 1077 1590 1095 1630 1114 1650 1134 1660 1158 1685 - - 1.13 1032 1405 1054 1470 1074 1525 1094 1560 1116 1595 1140 1620 1167 1640 1.08 1005 1260 1024 1275 1049 1370 1069 1440 1090 1475 1116 1505 1142 1535 1.04 980 1160 1002 1170 1022 1190 1044 1250 1066 1350 1090 1410 1117 1440 0.99 930 1060 957 1070 983 1080 1010 1100 1039 1160 1064 1260 1092 1340 0.94 877 950 908 975 941 1000 976 1020 1009 1050 1040 1100 1070 1225 0.90 - - - - 894 885 940 940 980 980 1014 1020 1047 1095 0.85 - - - - 855 815 903 860 950 905 988 940 1022 970 0.80 - - - - - - 884 815 925 850 964 880 1001 910 0.75 - - - - - - 864 770 908 805 948 835 987 870 0.71 - - - - - - - - 882 740 926 780 965 830 AIR FLOW AVAILABLE EXTERNAL STATIC PRESSURE-Pa* 223 248 273 298 322 347 372 M 3 /S RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 1.18 - - - - - - - - - - - - - - 1.13 - - - - - - - - - - - - - - 1.08 1170 1580 - - - - - - - - - - - - 1.04 1148 1480 1180 1530 - - - - - - - - - - 0.99 1121 1385 1155 1425 - - - - - - - - - - 0.94 1100 1285 1133 1340 1169 1385 - - - - - - - - 0.90 1079 1180 1110 1240 1143 1280 1178 1330 - - - - - - 0.85 1058 1060 1090 1135 1122 1190 1158 1240 - - - - - - 0.80 1035 960 1071 1030 1103 1100 1134 1140 1164 1175 - - - - 0.75 1020 900 1056 965 1088 1035 1118 1065 1145 1105 1170 1130 - - 0.71 1004 860 1038 880 1070 925 1101 980 1130 1045 1158 1075 - - AIR FLOW CFM M 3 /S CFM AVAILABLE EXTERNAL STATIC PRESSURE-IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2500 1059 1560 1077 1590 1095 1630 1114 1650 1134 1660 1158 1685 - - 2400 1032 1405 1054 1470 1074 1525 1094 1560 1116 1595 1140 1620 1167 1640 2300 1005 1260 1024 1275 1049 1370 1069 1440 1090 1475 1116 1505 1142 1535 2200 980 1160 1002 1170 1022 1190 1044 1250 1066 1350 1090 1410 1117 1440 2100 930 1060 957 1070 983 1080 1010 1100 1039 1160 1064 1260 1092 1340 2000 877 950 908 975 941 1000 976 1020 1009 1050 1040 1100 1070 1225 1900 - - - - 894 885 940 940 980 980 1014 1020 1047 1095 1800 - - - - 855 815 903 860 950 905 988 940 1022 970 1700 - - - - - - 884 815 925 850 964 880 1001 910 1600 - - - - - - 864 770 908 805 948 835 987 870 1500 - - - - - - - - 882 740 926 780 965 830 AIR AVAILABLE EXTERNAL STATIC PRESSURE-IWG* FLOW 0.90 1.00 1.10 1.20 1.30 1.40 1.50 CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2500 - - - - - - - - - - - - - - 2400 - - - - - - - - - - - - - - 2300 1170 1580 - - - - - - - - - - - - 2200 1148 1480 1180 1530 - - - - - - - - - - 2100 1121 1385 1155 1425 - - - - - - - - - - 2000 1100 1285 1133 1340 1169 1385 - - - - - - - - 1900 1079 1180 1110 1240 1143 1280 1178 1330 - - - - - - 1800 1058 1060 1090 1135 1122 1190 1158 1240 - - - - - - 1700 1035 960 1071 1030 1103 1100 1134 1140 1164 1175 - - - - 1600 1020 900 1056 965 1088 1035 1118 1065 1145 1105 1170 1130 - - 1500 1004 860 1038 880 1070 925 1101 980 1130 1045 1158 1075 - - 1. 380/415 Volts *. Includes allowances for a wet evaporator coil, 25mm [1in] filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than units with side duct airflows. 16 Johnson Controls Unitary Products

TABLE 13: BELT DRIVE BLOWER MOTOR AND DRIVE DATA MODEL BLOWER RANGE (RPM) MOTOR 1 HP RPM FRAME SIZE SERVICE FACTOR ADJUSTABLE MOTOR PULLY DESIG- NATION PITCH DIA. FIXED BLOWER PULLY BORE PITCH DIA. BORE PITCH LENGTH mm inch mm inch mm inch mm inch mm inch 5 TON 850-1180 1.5 1450 56 1.0 IVL44 69-97 2.8-3.8 22 7/8 127 5.0 25 1 922 36.3 A35 1. All motors have solid bases and are inherently protected. These motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device BELT DESIG- NATION TABLE 14: STATIC RESISTANCES RESISTANCE, Pa DESCRIPTION M /S 0.47 0.57 0.66 0.75 0.85 0.94 1.03 1.13 1.23 ECONOMIZER 1, 2 17.4 19.8 22.3 27.3 32.2 37.2 42.2 49.6 57.0 ELECTRIC 5-15KW 10.0 12.4 14.9 17.4 19.8 24.8 29.8 34.7 39.7 HEATERS 1 20-30KW 14.9 17.4 19.8 22.3 27.3 32.2 37.2 42.2 49.6 BOTTOM DUCT CONNECTIONS 1 14.9 17.4 19.8 22.3 24.8 27.3 29.8 34.7 39.7 RESISTANCE, IWG DESCRIPTION CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 ECONOMIZER 1, 2 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 ELECTRIC 5-15KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 HEATERS 1 20-30KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 BOTTOM DUCT CONNECTIONS 1 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.14 0.16 1. Deduct these resistance values from the available external static pressure shown in SUPPLY AIR BLOWER PERFORMANCE Tables. 2. The pressure through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 62.0 Pa [0.25 IWG], the unit will deliver less CFM during full economizer operation. TABLE 15: ELECTRIC HEATER CFM LIMITATIONS UNIT MODEL SIZE NOMINAL TONS 3 4 5 VOLTAGE 380/415-3-50 380/415-3-50 380/415-3-50 MINIMUM HEATER SIZE NOMINAL KW SUPPLY AIR 7 10 15 20 30 M 3 /S 0.47 0.57 0.57 0.61 - CFM 1100 1200 1200 1300 - M 3 /S 0.61 0.61 0.61 0.61 - CFM 1300 1300 1300 1300 - M 3 /S 0.75 0.75 0.75 0.75 0.75 CFM 1600 1600 1600 1600 1600 Johnson Controls Unitary Products 17

TABLE 16: ELECTRICAL DATA - BQ036, 048, & 060 Model Tonnage 3 4 5 Voltage Compressors RLA Each LRA Each 380-3-50 5.3 37.7 380-3-50 9.6 66 380-3-50 10.0 74 OD Fan Motors FLA Each ID Blower Motor FLA 1.3 1.7 415-3-50 5.3 37.7 1.3 1.7 1.3 2.0 415-3-50 9.6 66 1.3 2.0 1.3 2.7 415-3-50 10.0 74 1.3 2.7 Electric Heater Model No. 3 Heater kw Heater Amps Amps Size NONE 0.0 0.0 9.6 15 2CE04510746 2 4.3 6.5 17.8 20 2CE04511046 2 6.3 9.6 21.6 25 2CE04511546 2 8.5 12.9 25.8 30 2CE04512046 2 12.2 18.5 32.8 35 NONE 0.0 0.0 9.6 15 2CE04510746 2 5.1 7.1 18.5 20 2CE04511046 2 7.5 10.4 22.7 25 2CE04511546 2 10.2 14.2 27.4 30 2CE04512046 2 14.6 20.3 35.0 40 NONE 0.0 0.0 15.3 20 2CE04510746 2 4.3 6.5 23.5 30 2CE04511046 2 6.3 9.6 27.3 30 2CE04511546 2 8.5 12.9 31.4 35 2CE04512046 2 12.2 18.5 38.5 40 NONE 0.0 0.0 15.3 20 2CE04510746 2 5.1 7.1 24.2 30 2CE04511046 2 7.5 10.4 28.3 35 2CE04511546 2 10.2 14.2 33.0 35 2CE04512046 2 14.6 20.3 40.7 45 NONE 0.0 0.0 16.5 25 2CE04510746 2 4.3 6.5 24.7 30 2CE04511046 2 6.3 9.6 28.5 35 2CE04511546 2 8.5 12.9 32.6 35 2CE04512046 2 12.2 18.5 39.7 45 2CE04513046 2 18.1 27.5 50.9 60 NONE 0.0 0.0 16.5 25 2CE04510746 2 5.1 7.1 25.4 30 2CE04511046 2 7.5 10.4 29.5 35 2CE04511546 2 10.2 14.2 34.2 40 2CE04512046 2 14.6 20.3 41.9 45 2CE04513046 2 21.5 29.9 53.9 60 Note 1: HACR Type per NEC Note 2: These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code, the fuse block accessory 2FB04700546 is available for field installation. Note 3: Heaters are suitable for operation on 380/415V-3-50Hz power supply. Minimum Circuit Ampacity Max Fuse / BRKR 1 18 Johnson Controls Unitary Products

TABLE 17: PHYSICAL DATA EVAPORATOR BLOWER EVAPORATOR COIL CONDENSER FANS CONDENSER COILS COMPRESSOR (Qty. Per Unit) AIR FILTERS MODELS Centrifugal Blower (Dia. x Wd. mm) (in.) BQ 036 048 060 305 X 254 (12X10) 305 X 254 (12X10) 305 X 254 (12X10) Fan Motor HP (Direct Drive) 1/2 3/4 N/A Fan Motor HP (Belt Drive) N/A N/A 1 1/2 Rows Deep 4 3 3 Fins Per Inch (25mm) 16 15 15 Face Area m 2 (ft. 2 ) 0.40 (4.3) 0.57 (5.1) 0.57 (5.1) Propeller Dia. mm (in.) 610 (24) 610 (24) 610 (24) Fan Motor Hp 1/3 1/2 1/2 Nom. CFM 4300 4200 4500 Rows Deep 1 1 1 Fins Per Inch (25mm) 20 20 20 Face Area m 2 (ft. 2 ) 1.60 (17.1) 1.60 (17.1) 1.60 (17.1) Type / Quantity Reciprocating / 1 Reciprocating / 1 Scroll / 1 Quantity Per Unit (15 X 20 X 1 or 2 ) 2 2 2 Quantity Per Unit (14 X 25 X 1 or 2 ) 1 1 1 Face Area m 2 (ft. 2 ) 0.59 (6.6) 0.59 (6.6) 0.59 (6.6) CHARGE Refrigerant 22 kg (lbs./oz.) 3.6 (8/0) 4.2 (9/2) 3.7 (8.4) TABLE 18: ELECTRIC HEAT CORRECTION FACTORS NOMINAL VOLTAGE VOLTAGE kw CAP. MULTI- PLIER 380 380.627 415 415 0.75 TABLE 19: VOLTAGE LIMITATIONS 1 POWER SUPPLY MIN. VOLTAGE MAX. 380/415-3-50 342 456 1. Utilization Range A in accordance with ARI Standard 110. Johnson Controls Unitary Products 19

TYPICAL POWER WIRING TYPICAL CONTROL WIRING THERMOSTAT TERMINALS CONTROL TERMINAL BLOCK W1 W1 W2 Y1 1 W2 Y1 G Y2 2 OCC G R C P P1 Y2 X Smoke Detector 4 RC OCC X 5 6 R SD C R SD SD C 3 Jumper 24 VAC Class 2 TERMINALS ON A LIMITED NUMBER OF THERMOSTATS 1 2 3 4 5 Second stage heating not required on single stage heating units. Second stage cooling not required on single stage cooling units. Jumper is required if there is no Smoke Detector circuit. Jumper is required for any combination of R, RC, or RH. OCC is an output from the thermostat to indicate the Occupied condition. 6 X is an input to the thermostat to display Error Status conditions. FIGURE 2 - TYPICAL FIELD POWER & CONTROL WIRING 20 Johnson Controls Unitary Products

829 [32 5 / 8 ] mm[inch] 1140 [44 7 / 8 ] 2089 [82 1 / 4 ] 64 [2 1 / 2 ] 445 [17 1 / 2 ] 292 [11 1 / 2 ] 137 [5 3 / 8 ] 181 [7 7 / 8 ] 445 [17 1 / 2 ] 171 [6 3 / 4 ] 165 [6 1 / 2 ] 206 [8 1 / 8 ] 213 [8 3 / 8 ] FIGURE 3 - UNIT DIMENSIONS (3-5 TON HEAT PUMP) FRONT VIEW 699 [27 1 / 2 ] 41 [1 5 / 8 ] 699 [27 1 / 2 ] 502 [19 3 / 4 ] mm[inch] 260 [10 1 / 4 ] 1140 [44 7 / 8 ] DETAIL A FIGURE 4 - UNIT WITH ECONOMIZER RAINHOOD Johnson Controls Unitary Products 21

454 [17 7 / 8 ] 184 [7 1 / 4 ] 699 [27 1 / 2 ] 260 [10 1 / 4 ] 485 [19 1 / 8 ] 1140 [44 7 / 8 ] 111 [4 3 / 8 ] 89 [3 1 / 2 ] 210 [8 1 / 4 ] 305 [12] DETAIL B 419 [16 1 / 2 ] mm[inch] FIGURE 5 - UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD 292 [11 1 / 2 ] 76 [3] mm[inch] 445 [17 1 / 2 ] 165 [6 1 / 2 ] 445 [17 1 / 2 ] 292 [11 1 / 2 ] 200 [7 7 / 8 ] 117 [4 5 / 8 ] FIGURE 6 - UNIT DIMENSIONS (REAR VIEW) 22 Johnson Controls Unitary Products

FILTER ACCESS BLOWER MOTOR ACCESS DOT PLUGS FIELD-SUPPLIED DISCONNECT SWITCH LOCATION MOUNTING BRACKET FOR DICONNECT SWITCH (Shipped attached to the blower housing inside the blower compartment) A,B WIRING ENTRY (See Detail B ) DISCONNECT SWITCH LOCATION AND MOTOR ACCESS PANEL FOR UNIT WITH BELT-DRIVE OPTION CONTROL BOX ACCESS FIGURE 7 - DISCONNECT/BLOWER ACCESS LOCATION TABLE 20: UTILITIES ENTRY HOLE OPENING SIZE (DIA.) USED FOR Side A 22 / 0.88 KO 1 Control Wiring 2 Bottom B 51 / 2.0 KO 1 Power Wiring Side Bottom C 41 / 1.63 KO Gas Piping (Front) D 38 / 1.5 KO Gas Piping (Bottom) 1. Opening in the bottom to the unit can be located by the side in the insulation. 2. Do not remove the 2 knockout ring. TABLE 21: MINIMUM CLEARANCES LOCATION CLEARANCE (mm / In.) 610 / 24.0 (Cooling/Electric Front Heat) 813 / 32.0 (Gas Heat) 305 / 12.0 (Less Economizer) Back 914 / 36.0 (With Economizer or Fixed Air/Motorized Damper) 610 / 24.0 (Less Economizer) Left Side (Filter Access) 914 / 36.0 (With Economizer) Right Side (Cond. Coil) 610 / 24.0 Below Unit 1 0 Above Unit 2 1829 / 72.0 (For Condenser Air Discharge) 1. Units may be installed on combustible floors made from wood or class A, B, or C roof covering material. 2. Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. Johnson Controls Unitary Products 23

FIGURE 8 - TYPICAL APPLICATIONS 24 Johnson Controls Unitary Products

X 1140 BACK OF UNIT mm[inch] 1140 A [44 7 / 8 ] [44 2089 7 / 8 ] [82 1 / 4 ] D F APPROXIMATE CENTER OF GRAVITY FRONT OF UNIT C Y B CONDENSER COIL END OF UNIT X APPROXIMATE CENTER OF GRAVITY A E FRONT OF UNIT B BACK OF UNIT D 2089 [82 1 / 4 ] Y C mm[inch] CONDENSER COIL END OF UNIT FIGURE 9 - FOUR AND SIX POINT LOADING TABLE 22: BQ 4 POINT LOADS WEIGHT DISTRIBUTION (kg / Lbs.) UNIT TOTAL A B C D BQ036 252 / 555 56 / 123 55 / 121 70 / 154 71 / 157 BQ048 270 / 595 60 / 132 59 / 130 75 / 165 76 / 168 BQ060 281 / 620 62 / 138 61 / 135 78 / 172 79 / 175 TABLE 23: BQ 6 POINT LOADS WEIGHT DISTRIBUTION (kg / Lbs.) UNIT TOTAL A B C D E F BQ036 252 / 555 37 / 82 37 / 81 36 / 80 46 / 102 47 / 104 48 / 105 BQ048 270 / 595 40 / 88 40 / 87 39 / 86 50 / 110 50 / 111 51 / 112 BQ060 281 / 620 42 / 92 41 / 91 41 / 90 52 / 114 52 / 116 53 / 117 TABLE 24: CENTER OF GRAVITY DIMENSION 3-5 TON X 1035 / 40-¾ Y 502 / 19-¾ TABLE 25: OPERATING WEIGHTS (kg / Lbs.) MODEL SIZE 3 TON 4 TON 5 TON BASIC UNIT BQ 252 / 555 270 / 595 281 / 620 Economizer 23 / 50 Motorized Damper 12 / 26 OPTIONS 5-7 kw 8 / 18 Electric Heater 10-15 kw 10 / 23 20-30 kw 13 / 28 Roof Curb 42 / 92 ACCY. Barometric Relief / Fixed Air Damper 5 / 10 Belt-Drive Blower 2.3 / 5 Johnson Controls Unitary Products 25

51 [2] 356 [14] 495 [19 1 / 2 ] 946 [37 1 / 4 ] 51 [2] 495 [19 1 / 2 ] 114 [4 1 / 2 ] 495 [19 1 / 2 ] 51 [2] 1854 [73] DUCT SIZES: SUPPLY AIR = 489 X 489 [19 1 / 4 X 19 1 / 4 ] RETURN AIR = 489 X 489 [19 1 / 4 X 19 1 / 4 ] mm[inch] FIGURE 10 - ROOF CURB DIMENSIONS 26 Johnson Controls Unitary Products

Johnson Controls Unitary Products 27

Subject to change without notice. Printed in U.S.A. Copyright 2009 by Unitary Products. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 254575-XTG-C-0109 Supersedes: 254575-YTG-B-0507