Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Similar documents
Single Channel Loop Detector

Operating Instructions

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

48 SERIES Relay interface modules 10 A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

49 Series - Relay interface modules A. Features

38 Series - Relay interface modules A

PNOZsigma - Base units

38 Series - Relay interface modules A

Safety technique. Emergency stop module BO 5988 safemaster

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

W 27-2: The photoelectric switch series with expanded possibilities

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RY2 miniature industrial relays

E-STOP relays, safety gate monitors

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

40 Series - Miniature PCB/Plug-in relays A. Features

Contact expansion modules

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

E-STOP relays, safety gate monitors

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

SKR - industry relay

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Contact expander modules

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

80 Series - Modular timers 16 A. Features

WD-AMX Water Detection Controllers

13 SERIES. Electronic step relays A

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Pluggable interface relays CR-P Pcb relays

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Speed Control Relays SX2

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Operating Instructions

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

MasterINTERFACE 39 Series - Relay interface modules

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

Operating Instructions

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Catalog. Arc Guard System TM TVOC-2

Quick Connect. quick - simple - efficient.

E-STOP relays, safety gate monitors

RM4TG20 three-phase network control relay RM4-T - range V

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

60 Series - General purpose relays 6-10 A. Features

MasterINTERFACE 39 Series - Relay interface modules

Panel Meters and Controllers Modular Panel Meter Type EDM 35

instabus KNX / EIB System System E F G H

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Control Devices Catalogue. Control Devices. Preferred and Standard Products

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Thyristor-controlled power supplies and battery chargers

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Charge Controller CC611/CC612 Preliminary datasheet

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Safety Relays ESM/ESM-F

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Modular I/O System Analog and Digital Interface Modules

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Short information Parameters are programmed via front-side membrane keypad

Contents. Document information

DS 600. A contact free flux gate based current measurement sensor 600A rms

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

HERZ-Thermal Actuators

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Three-phase monitoring relay CM-PFE

Electronic overload relay EF65, EF96 and EF146

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

FIREDEX Conventional Fire Panels

TMS TANK MANAGEMENT SYSTEM

E-STOP relays, safety gate monitors

Electronic overload relay EF19 and EF45

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Preset Counter signo 721

Electronic, Digital and Mechanical Vibration Switches

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

User's Guide. True RMS Industrial Multimeter

Drayton Digistat +2RF/+3RF

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Safety automation solutions

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

These tables allow you to quickly select only the items, then check if all product s technical data meet your application requirements.

Programming Logic controllers

Transcription:

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation via 11 pin circular plug Rated operational voltage: 24 VAC/DC, 115 VAC or 230 VAC Pulse or presence relay output Output 1A/250 VAC SPDT relay LED indication for power, relay status and loop fault Sensitivity boost only LDP1 Selectable frequency prevents cross-talk Direction logic only LDP2 Product De scrip tion Loop detectors for detection of vehicles. The vehicle loop detector is designed to handle all parking, drive-through and access control applications for controlling doors, gates, barriers or fences. Type Selection The principle is based on a change in the inductance within the loop when a metallic object (vehicles) is passing. The microprocessor evaluates the changes. Ordering Key Type Plug mounting Loop inputs Function Adjustment Outputs Relay versions Power supply LDP1 SA1B 230 Mounting Relay Ordering no. Ordering no. Ordering no. Supply: 24 VAC/DC Supply: 115 VAC Supply: 230 VAC Single loop SPDT LDP1SA1BM24 LDP1SA1B115 LDP1SA1B230 Dual loop SPST LDP2TA2BM24 LDP2TA2B115 LDP2TA2B230 Specifications Rated operational voltage (U B) Pin 2 & 1 230 195 to 265 VAC, 45 to 65 Hz 115 98 to 132 VAC, 45 to 65 Hz M24 19.2 to 28.8 VAC/DC Rated insulation voltage <2.0 kvac (rms) Rated impulse withstand voltage 4 kv (1.2/50 µs) (line/neutral) Rated operational power AC supply 3 VA AC/DC supply 1.5 VA / 1.5 W Power on delay (t V) < 10 sec Typ. 4 sec Outputs Minimum switching current 10 ma @ 12 V Rated insulation voltage 250 VAC (rms) (cont./elec.) Relay Rating (AgNi 90/10) µ (micro gap) Resistive loads AC1 1 A / 250 VAC (250 VA) DC1 1 A / 30 VDC (30 W) Mechanical life (typical) 15 x 10 6 operations @ 18 000 imp/h Electrical life (typical) AC1 > 250 000 operations Sensitivity 8 sensitivity settings available Frequency range 13-120 khz Loop inductance 15-1500 µh Operating frequency (f) Relay output 1 HZ Response time 400 ms Environment Overvoltage category III (IEC 60664) Degree of protection IP 20 (IEC 60529, 60947-1) Pollution degree 2 (IEC 60664/60664A, 60947-1) Temperature Operating -40º to +70ºC (-40º to + 158ºF) Storage -50º to +85ºC (-58º to +185ºF) Housing material NORYL SE1, light grey Weight AC supply 150 g AC/DC supply 85 g Approvals UL508 CE marking Yes Specifications are subject to change without notice (24.09.13) 1

Mode of Operation Application The LDP Vehicle Loop Detector is based on microprocessor technology, which has enabled a large number of functions to be implemented. The functions are primarily for use in the Parking/Access Control Industry like control for gates, barriers, fences, etc. Standard operations are implemented including programmable pulse and presence option. Principle The Vehicle Loop Detector is based on the inductive principle, using a coil of wire buried in the driveway and connected to the loop detector. The change in inductance will be measured as a change in frequency. The output relay activates when the loop is activated and releases again when the loop returns to a non-activated condition. Setup The loop has to be in a passive condition (no object in the loop area) during startup and adjustment. The loop detector will automatically calibrate when the reset button has been activated, which will be indicated by the yellow LED flashing. The functioning can now be checked by activating the loop with the actual object. Now the yellow LED will go on, and the output relay will be activated according to the dip-switch settings. If the loop detector does not react, the sensitivity must be manual adjusted by means of the dip-switches. Important: reset the system after changing the Dipswitch settings. Temperature compensation The frequency will increase as a result of decreasing temperatures and vice versa. To compensate for this, or any other situation that courses slowly change in frequency, the LD auto tunes constantly. That means if the frequency changes slowly there will be no detection. The auto tune function compensates for both increasing or decreasing in frequency. Fault detection This function is useful if the cable disconnect. The alarm will be indicated via the red LED in front of the housing. This LED is constantly lighting when the loop is open or too large and flashing when a short circuit occurs or a loop is too small. Loop Under Roadway Sensitivity 8 sensitivity settings are available on the dip-switches in front of the module, to allow flexibility in configuration and application (Compensation for variation in loop construction). Reset switch The reset switch enables the detector to be manually reset during commissioning and testing. The detector will re-tune the sensing loop and become ready for vehicle detection. Relay output The single loop detector has two SPDT relays one for pulse output and one for presence output. The dual loop detector has two SPST relays one for each loop. Pulse output (one shot): It is possible to select the length of the output period to 0.2s or 1 second. The pulse output can be setup to activate on detection of a vehicle or when the vehicle leaves the loop. Presence output: The output will be activated as long as there is a vehicle parked in the loop. It will be possible to activate a filter (-delay of 2 seconds), which prevents a false detection from a small or fast moving object. Pulse output mode The relay activates only for a short period when the vehicle enters or leaves the loop. Permanent output mode The relay will remain active as long as there is a vehicle parked in the loop. Extends the pulse length from 0.2 sec to 1 sec. On-delay Prevents false detections of small or fast moving objects. Sense boost (only single channel loop detector) This feature sets the undetected level to maximum sensitivity and is used to prevent loss of detection of high-bed vehicles. Selectable frequency The frequency of the loop is determined by the inductance of the loop and the frequency switch setting. If the frequency switch is on, the frequency is reduced. It may be necessary to change the frequency to prevent cross talk between adjacent loops. The frequency function will only change the frequency of one channel of the dual loop detector. Important: Be careful when installing the detector next to another inductive load, as this can have an effect on the detector and cause false detections. Operation Diagram LDP1 / Presence and Pulse mode Vehicle Entering Vehicle Leaving Loop Relay 1, Presence t : 2 s 2 Specifications are subject to change without notice (24.09.13)

Operation Diagram (cont.) LDP2 / Direction Logic Mode Vehicle Passing, 1 to 2 Vehicle Passing, 2 to 1 t : 2 s t : 2 s LDP2 / Presence Mode Vehicle Passing Relay 1, Presence t : 2 s Relay 2, Presence t : 2 s LDP2 / Pulse Entering Vehicle Entering t : 2 s t : 2 s LDP2 / Pulse Leaving Vehicle Leaving t : 2 s t : 2 s Specifications are subject to change without notice (24.09.13) 3

Dip Switch Settings LDP1 LDP2 Sensitivity Minimum Maximum 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 1 sec 0.2 sec 4 4 Leaving 5 5 6 6 7 7 A 8 8 Entering 2 sec On B 1 sec 0.2 sec 4 4 Leaving 5 5 6 6 Pulse 7 7 A 8 8 Entering 2 sec Pulse mode On delay Sensitivity boost Loop frequency Cross talk Presence Pulse/presence mode B Pulse mode On delay Loop frequency Cross talk Direction logic Function The Dual loop detector (LDP2) is implemented with direction logic as standard. The function enables the detector to give a pulse output on relay#1 for a vehicle travelling from loop 1 to loop 2 and a pulse output on relay#2 for a vehicle travelling from loop 2 to loop 1. Direction Relay 2 Important: Reset the detector after changing the Dip-switch settings If a vehicle is detected, and the corresponding direction is indicated, both loops must be in a non-activated condition again before the next object can be detected. For Direction logic mode set Dipswitch 5 to Entering and Dipswitch 7 to Presence. Relay 1 Direction Loop Diagram Loop installation The loop geometry must be adapted to the respective application. The setup will be optimal if the loop has the same size as the object to be detected. After determining the loop geometry, a groove must be cut in the ground for installing the loop. Cut an inclined groove of 45 angle at the corners of the loop, which will protect it from excessive wear. Clean the groove for moisture and place the wire as tight as possible along the button of the groove. Before sealing up the groove, it is recommandable to check the loop inductance using a measuring device. Optimum value: 80-300 µh. When sealing up the groove, ensure that the temperature of the sealing compound does not exceed the max temperature of the loop insulation, as this might cause an earth fault. Loop turns The number of turns strongly depends on the circumference of the loop. The smaller the loop, the more turns are required. Cable Recommandations - Use 1.5mm squared cable. Use silicon coated cable, if placed directly into the ground - Use 2m of spacing between two adjacent loops. - Use screened feeder cable in electrically noisy environments or where feeder runs parallel to power cables. Max Max depth depht into road: 50mm Typical 30 mm Loop circumference No. of turns (m) >10 2 6-10 3 <6 4 300 mm Twisted wire --> 20 Twisted turns wire per meter -> 20 turns per meter max length: 20 mt max lenght: 20 m 45 2 m 1 m ROAD 300 mm 4 Specifications are subject to change without notice (24.09.13)

Dimension Drawing Wiring Diagram Plug version 45 LDP1 63 μ Pulse Pres 5 4 3 6 7 8 9 21 2 1 11 10 SUPPLY 80 35,5 LDP2 Loop 2 μ 4 3 5 6 7 Loop 2 8 9 2 1 11 10 SUPPLY Pin configuration Pin n. Single Channel Detector Dual Channel Detector 1 Supply Supply 2 Supply Supply 3 Pulse relay NO NO Loop #1 4 Pulse relay COM Loop #1 5 Presence relay NO Loop #2 6 Presence relay COM Loop #2 7 Loop Pulse/Presence relay #2 NO 8 Loop Pulse/Presence relay #2 COM 9 Earth Earth 10 Presence relay NC Pulse/Presence relay #1 NO 11 Pulse relay NC Pulse/Presence relay #1 COM Accessories Delivery Contents 11-pole circular socket ZPD11 Detector Packaging: Carton box Specifications are subject to change without notice (24.09.13) 5