Replacing the chassis on a FAS20xx system



Similar documents
Storage Efficiency Express Guide For 7-Mode Administrators Learning Cluster-Mode

NetApp FAS/V-Series Storage Replication Adapter for Clustered Data ONTAP

V-Series Systems Implementation Guide for EMC CLARiiON Storage

Data ONTAP DSM for Windows MPIO Release Notes

Fibre Channel and iscsi Configuration Guide

Configuration Examples for FAS2240 Systems

SnapDrive for UNIX Quick Start Guide (IBM AIX, HP-UX, Linux, Solaris )

SnapManager 5.0 for Microsoft Exchange Installation and Administration Guide

Clustered Data ONTAP 8.2

Clustered Data ONTAP 8.2

Clustered Data ONTAP 8.2

NetApp Storage Array Management Pack for Operations Manager 2.1

SnapManager 8 for Microsoft SharePoint Disaster Recovery User s Guide

Hot-swapping a power supply

SnapManager 7.1 for Microsoft SharePoint Job Monitor User s Guide

Logical Replication (LREP) Tool User Guide

NetApp E-Series Plug-in for Microsoft SQL Server Management Studio Installation Guide

SnapManager 8.1 for Microsoft SharePoint Job Monitor User s Guide

Data ONTAP 7.3 Storage Efficiency Management Guide

Data ONTAP 7.3 Data Protection Online Backup and Recovery Guide

NetApp SANtricity Add-in for Microsoft SQL Server Management Studio 1.3

How To Manage A System On A Pc Or Mac Or Mac (Or Mac) With A Hard Drive Or Ipnet (Or Ipnet) On A Computer Or Mac) On Your Computer Or Computer (Or Pc Or Pc Or Ipro) On

Data ONTAP 7.3 System Administration Guide

NetApp E-Series Storage Systems Concepts for SANtricity ES Storage Manager Version 10.86

Data ONTAP 7.3 Storage Management Guide

Single Mailbox Recovery 6.1 ExtractWizard Release Notes

SGI InfiniteStorage 4000 Series and 5000 Series Concepts Guide for SANtricity ES Storage (ISSM 10.86)

Clustered Data ONTAP 8.2

Data ONTAP 7.3 File Access and Protocols Management Guide

Config Advisor 3.2. Installation and Administration Guide

NetApp E-Series Storage Systems Concepts for SANtricity ES Storage Manager Version 10.86

SnapManager for Microsoft SharePoint Server Release Notes

Open Systems SnapVault Installation and Administration Guide

NetApp E-Series Storage Systems. Command Line Interface and Script Commands for Version 10.84

SGI InfiniteStorage 4000 Series and 5000 Series Configuring and Maintaining a Storage Array Using the Command Line Interface (ISSM 10.

Benefits of Fibre Channel (FC) SANs

SGI InfiniteStorage 4000 Series and 5000 Series Configuring and Maintaining a Storage Array (ISSM 10.86)

Data ONTAP Mode NCDA NSO-154 Certification Study Guide

At A Glance. Guide To NetApp Certification

Setting up CIFS shares and joining the Active Directory. Why join an N series storage system to Active Directory?

NetApp E-Series Storage Systems Initial Configuration and Software Installation. For SANtricity ES Storage Manager 10.86

Removing memory and option cards

IBM System Storage. N3300 Installation and Setup Instructions

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

NetApp Training and Certification 2009

UPGRADING AND SERVICING GUIDE

Installing the Video Input and TV Tuner Cards in a Compact Computer or a Dual PCI-Slot Tower Computer

Cloud ONTAP 8.3 for Amazon Web Services

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Inspiron 13. Service Manual Series. Computer Model: Inspiron Regulatory Model: P57G Regulatory Type: P57G001

Software Storage Platform Mixing Rules

Inspiron 15. Service Manual Series

Clustered Data ONTAP 8.3

Accessing the printer system board

Dell Inspiron 660s Owner s Manual

Integrating Mac OS and NetApp Storage

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Upgrading and Servicing Guide

Front Panel Board Cable Replacement Instructions

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

Navigating VSC 6.0 for VMware vsphere

HP SATA/SAS hard drive and Solid State Drive installation

Case Study and Tutorial: HTTPS Reverse Proxy and Authentication with LDAP

Rack Installation Instructions

INNOVATIVE ENTERPRISE STORAGE SOLUTIONS

Upgrading a single-controller FAS2220 system by moving its internal disk drives to an external disk shelf

Memory Modules User Guide

Service Guide. Gateway M275

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

How to Set Up Your NSM4000 Appliance

Upgrading or Replacing a Host Interface Card in the 6580/6780 Controller Module

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Clustered Data ONTAP 8.3

430 Power/Electronics Replacement

Processor Cage Fans, Front and Rear Replacement Instructions

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

HP AD397A rx2660 SAS Smart Array P400 Controller Installation Guide Manufacturing Part Number: AD A February 2007

Upgrading or Replacing a Host Interface Card in a Xanadu-230 Controller-Drive Tray

Clustered Data ONTAP 8.3

SC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two

HP 22-in-1 Media Card Reader

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Installing Your 960 or 980 Server into a Rackmount Cabinet

HP Integrity rx2660 Server Installation Guide

Power Supply Guide Version 1.0 for D-Show

Rack installation instructions

HP 16/18-Port Cable Management Kit Installation Guide

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

SAS Disk Shelves Universal SAS and ACP Cabling Guide

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Wall-Mounting your HP computer. User Guide

Memory Installation Guide

Pricing - overview of available configurations

Small form factor bay converter and hard drive installation

High Availability and MetroCluster Configuration Guide For 7-Mode

HP UPS R1500 Generation 3

TeamPoS 2000 Installation Instructions Upgrade to M Motherboard

SECURITY SYSTEM SMART SIREN KIT

Transcription:

Replacing the chassis on a FAS20xx system To replace the chassis, you must perform a specific sequence of steps.. Before you begin All other components in the system must be functioning properly; if not, contact technical support. About this task You can use this procedure with all versions of Data ONTAP supported by your system. In this procedure, a Cluster-Mode system refers to a system running Data ONTAP 8.0 Cluster-Mode. A 7-Mode system refers to a system running Data ONTAP 8.0 7-Mode or releases prior to Data ONTAP 8.0. Only the FAS2040 supports Data ONTAP 8.0. For other FAS20xx systems, follow the directions for 7-Mode systems. This procedure refers to HA pairs, which in releases prior to Data ONTAP 8.0 were called active/active configurations. This procedure assumes you are moving all disk drives to the new chassis. This procedure assumes you are moving all controller modules to the new chassis. 1. Shutting down the nodes on page 1 2. Removing the controller module on page 3 3. Removing the power supplies on page 4 4. Moving disk drives to the new chassis on page 4 5. Moving the FAS2050 x4 filler module to a new FAS2050 chassis on page 5 6. Removing the chassis from the equipment rack or system cabinet on page 6 7. Installing the new chassis and bezel on page 6 8. Installing the power supplies in the new chassis on page 7 9. Reinstalling the controller module s and booting the system on page 7 10. Running diagnostics on the chassis on page 8 11. Completing the replacement process on page 8 Shutting down the nodes You must shut down the node or nodes in the chassis prior to moving them to the new chassis. About this task If you cannot gracefully shut down the nodes due to system constraints, such as backplane failure, you can move the controller modules to a new system chassis and not lose any data on the controller modules as long as you move the system disks to the new chassis. In this case, use the procedure for moving the controller modules when you cannot shut them down. 1. If your system has two controller modules, you must disable the HA pair with one of the following commands: If your system is configured as a... 7-Mode system Then issue this command... cf disable 215-03118_B0 Copyright 2010 NetApp, Inc. All rights reserved. 1

If your system is configured as a... Cluster-Mode system with two nodes in the cluster Cluster-Mode system with more than two nodes in the cluster Then issue this command... node0::> cluster ha modify -configured false node::> storage failover modify -node node0 - enabled false node::> storage failover modify -node node0 - enabled false 2. Enter one of the following commands from the system console: If your system is configured as a... 7-Mode system Cluster-Mode system Then issue this command... halt halt local Attention: You must perform a clean system shutdown before replacing system components to avoid losing unwritten data in the nonvolatile memory (NVMEM). The NVMEM LED is located on the controller module to the right of the network ports, marked with a battery symbol. If the NVMEM LED is flashing, there is content in the NVMEM that has not been saved to disk. You need to reboot the controller module and proceed from the beginning of this procedure. If repeated attempts to cleanly shut down the controller module fail, be aware that you might lose any data that was not saved to disk. 1 NVMEM LED Note: The preceding illustration shows a FAS2050 system. The NVMEM LEDs are in a similar location on a FAS2020 or FAS2040 system. The Platform Monitoring Guide contains more information about the NVMEM LEDs. 3. Repeat the preceding step for the second controller, if necessary. 4. If you are not already grounded, properly ground yourself. 5. Turn off the power supplies and unplug both power cords from the power source: 2 Replacing the chassis on a FAS20xx system

If your system uses... AC power DC power Then... Unplug the power cords from the power source, and then remove the power cords. Remove the power at the DC source, and then remove the DC wires, if necessary. Shutting down the controller modules when you cannot shut them down If you cannot gracefully shut down the controller modules, you can remove the modules as long as you do not disconnect the NVMEM battery in the controller module. Before you begin You cannot shut down the controller modules gracefully due to system constraints, such as backplane failure. About this task You must not disconnect the NVMEM battery, to ensure that data in the NVMEM is retained. 1. Enter one of the following commands from the system console: If your system is configured as a... 7-Mode system Cluster-Mode system Then issue this command... halt halt local 2. Repeat the preceding step for the second controller, if necessary. 3. If you are not already grounded, properly ground yourself. 4. Turn off the power supplies and unplug both power cords from the power source: If your system uses... AC power DC power Then... Unplug the power cords from the power source, and then remove the power cords. Remove the power at the DC source, and then remove the DC wires, if necessary. 5. Remove any cabling from the controller module. Make sure that you keep track of where the cables were connected to the controller module. Removing the controller module To remove the controller module or modules from the chassis, you must perform a specific sequence of steps. 1. If you are not already grounded, properly ground yourself. 2. Unplug the system cables from the controller module, as needed, and keep track of where the cables were connected. 3. Pull the cam handle downward and slide the controller module out of the system. 4. Repeat the preceding steps for the second controller module, if necessary. 3

Removing the power supplies To remove the power supplies, you must perform a specific sequence of steps. 1. If you are not already grounded, properly ground yourself. 2. Loosen the thumbscrew on the power supply cam handle, lower the cam handle, and slide the power supply out of the chassis. Make sure that you support the power supply with your free hand. 3. Repeat the preceding steps for the second power supply. Moving disk drives to the new chassis To move disk drives from the old chassis to the new chassis, you must perform a specific sequence of steps. 1. Gently remove the bezel from the front of the system. 2. Gently remove a disk drive from the chassis, if applicable, by pinching the tab at the top of the cam handle and swinging the cam handle open. 1 2 Pinch the tab Swing cam handle open The disk drive should disengage from the chassis, allowing it to slide free of the chassis. Note: Disk drives are fragile. Handle them as little as possible to prevent damage to them. 3. Remove the disk drive from the chassis. 4. Align the disk drive from the old chassis with the same bay opening in the new chassis. 5. Gently push the disk drive into the chassis as far as it will go. The cam handle engages and begins to lift upward. 4 Replacing the chassis on a FAS20xx system

6. Firmly push the disk drive the rest of the way into the chassis and lock the cam handle by pushing it up and against the disk drive holder. You will hear it click when it is secure. 7. Repeat 2 though 6 for the remaining disk drives in the system. See the Hardware Overview for more information. 8. Go to the next task. If you are replacing the chassis for a... FAS2050 FAS2020 or FAS2040 Then... Remove the X4 filler module and install it in the new chassis. Remove the chassis from the equipment rack or system cabinet. Moving the FAS2050 x4 filler module to a new FAS2050 chassis If you have a FAS2050 system, you must remove the x4 filler below the disk drives and move it to the new chassis. If you are replacing a FAS2020 or FAS2040 system chassis, you can skip this procedure. 1. Using the ball stud tool, loosen and remove the left and right ball studs and set them aside. 1 x4 filler module 5

2 3 4 5 Guides Ball stud tool Loosen Ball stud 2. Grasp the x4 filler module near the ball stud holes and slide the filler module straight back and out of the system chassis. 3. Take the x4 filler module to the new chassis and install it by aligning the guides on the x4 filler module with the slots on the inside of the open bay on the new chassis. Make sure that you insert the x4 filler module with the guides facing down. 4. Gently and evenly slide the X4 filler module into the chassis. Make sure that the module does not bind when you are pushing it into the chassis. 5. Install the left ball stud and then the right ball stud, and tighten them to the chassis using the ball stud tool. Removing the chassis from the equipment rack or system cabinet You must remove the existing chassis from the rack or system cabinet before you can install the new one. 1. Remove the ear covers, if applicable. 2. Remove the screws on the ears of the chassis. 3. Remove the rear rail mounting bracket screws, if applicable. 4. Using two people, slide the chassis off the slide rails and set it aside. Installing the new chassis and bezel You must install the new chassis and bezel in the equipment rack or system cabinet. 1. If you are not already grounded, properly ground yourself. 2. Remove the plastic mounting ear covers from the front of the chassis. 3. Using two people, install the empty chassis into the system cabinet or equipment rack by guiding the chassis onto the rail guides in a system cabinet or angel wings in an equipment rack. 4. Slide the chassis all the way into the system cabinet or equipment rack. 5. Secure the front of the chassis to the system cabinet or equipment rack upright, using the screws you removed from the chassis. 6. Install the plastic mounting ear covers, if applicable. 7. Align the bezel with the ball studs and gently push the bezel onto the ball studs. 6 Replacing the chassis on a FAS20xx system

8. If you have a FAS2050 system, set the new chassis ID to the same ID as the old chassis, by using the thumbwheel on the front of the chassis. Installing the power supplies in the new chassis To install the power supplies, you must follow these steps to place the power supply in the chassis, secure it, and reconnect the power cord. 1. Make sure that the on/off switch of the new power supply is in the Off position. 2. If you are not already grounded, properly ground yourself. 3. Align the edges of the power supply with the opening in the system chassis and gently push the power supply into the chassis until the cam handle begins to rise. 4. Push on the edges of the power supply to seat it all the way into the chassis, and then push the cam handle to the closed position. 5. Tighten the thumbscrew on the power supply cam handle. 6. Reconnect the power cord and secure it to the power supply using the cable retaining clip. Reinstalling the controller modules and booting the system You must install and cable the controller module or modules in the new chassis, and then boot the system. 1. Close the module cover, if necessary, by aligning the controller module cover with the notches on the sides of the controller module and sliding the cover down and forward to seat it. 2. Align the end of the controller module with the opening in the chassis, if necessary, and then gently push the controller module halfway into the system. 3. Recable the system, as needed. When recabling, remember to reinstall the media converters (SFPs) if you are using fiber cables. 4. Push the controller module all the way into the system, firmly push the cam handle to finish seating it, and then push the cam handle to the closed position. 5. Repeat the preceding steps to install the other controller module, if necessary. 6. Reconnect the power cables to the power supplies and to the power sources, and then turn on the power. 7. Press Ctrl-C to stop the boot process. 8. Enter the following command at the boot loader prompt: boot_diags 7

Running diagnostics on the chassis After installing a new chassis, you should run diagnostics. 1. Select and run diagnostic tests on the system. 2. After you complete the tests, exit diagnostics. 3. Enter the following command to return the system to normal operation: boot_ontap 4. Repeat the preceding steps for the other controller module, if necessary. 5. If your system is in an HA pair, enable it again. You use the cf enable command (in 7-Mode) or storage failover modify - node node_name - enabled true command (in Cluster-Mode) to reenable your HA pair. Related information NetApp Hardware Diagnostics Guide: http://now.netapp.com/now/knowledge/docs/hardware/netapp/diag/diag.pdf Completing the replacement process After you replace the part, you can return the failed part to NetApp, as described in the RMA instructions shipped with the kit. Contact NetApp technical support at 888-463-8277 (North America), 00-800-44-NETAPP (Europe), or +800-800-80-800 (Asia/ Pacific) if you need the RMA number or additional help with the replacement procedure. Trademark information NetApp, the Network Appliance logo, the bolt design, NetApp-the Network Appliance Company, Cryptainer, Cryptoshred, DataFabric, DataFort, Data ONTAP, Decru, FAServer, FilerView, FlexClone, FlexVol, Manage ONTAP, MultiStore, NearStore, NetCache, NOW NetApp on the Web, SANscreen, SecureShare, SnapDrive, SnapLock, SnapManager, SnapMirror, SnapMover, SnapRestore, SnapValidator, SnapVault, Spinnaker Networks, SpinCluster, SpinFS, SpinHA, SpinMove, SpinServer, StoreVault, SyncMirror, Topio, VFM, VFM Virtual File Manager, and WAFL are registered trademarks of NetApp, Inc. in the U.S.A. and/or other countries. gfiler, Network Appliance, SnapCopy, Snapshot, and The evolution of storage are trademarks of NetApp, Inc. in the U.S.A. and/or other countries and registered trademarks in some other countries. The NetApp arch logo; the StoreVault logo; ApplianceWatch; BareMetal; Camera-to-Viewer; ComplianceClock; ComplianceJournal; ContentDirector; ContentFabric; Data Motion; EdgeFiler; FlexShare; FPolicy; Go Further, Faster; HyperSAN; InfoFabric; Lifetime Key Management, LockVault; NOW; ONTAPI; OpenKey, RAID-DP; ReplicatorX; RoboCache; RoboFiler; SecureAdmin; SecureView; Serving Data by Design; Shadow Tape; SharedStorage; Simplicore; Simulate ONTAP; Smart SAN; SnapCache; SnapDirector; SnapFilter; SnapMigrator; SnapSuite; SohoFiler; SpinMirror; SpinRestore; SpinShot; SpinStor; vfiler; VPolicy; and Web Filer are trademarks of NetApp, Inc. in the U.S.A. and other countries. NetApp Availability Assurance and NetApp ProTech Expert are service marks of NetApp, Inc. in the U.S.A. IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. A complete and current list of other IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml. Apple is a registered trademark and QuickTime is a trademark of Apple, Inc. in the U.S.A. and/or other countries. Microsoft is a registered trademark and Windows Media is a trademark of Microsoft Corporation in the U.S.A. and/or other countries. RealAudio, RealNetworks, RealPlayer, RealSystem, RealText, and RealVideo are registered trademarks and RealMedia, RealProxy, and SureStream are trademarks of RealNetworks, Inc. in the U.S.A. and/or other countries. 8 Replacing the chassis on a FAS20xx system