Medium-voltage transformers



Similar documents
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

Quick Connect. quick - simple - efficient.

Vario-Series Accessories

LOW-VOLTAGE CURRENT TRANSFORMERS

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Measurement and Instrumentation

Current transformers (CT) & Shunts

Enhanced Quality with a Touch of Style

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

keep your measure under control

Measurement devices Accessories for analogue and digital instruments

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

SINEAX U553 Transducer for AC Voltage

A project to optimise quality and energy efficiency must include metering

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Thermal-Magnetic Circuit Breaker M1-..

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

CURRENT TRANSFORMERS INSTALLATION GUIDE

5SV Residual Current Protective Devices

How To Build A Low Voltage Capacitor Lvcp

Tape Wound, Split Core and Ebony Current Transformers

Product Information Sheet UH28CS-12kV Hi Pot Tester

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

T Substation Maintenance and Commissioning Test Equipment

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PC 4/ 4-ST-7,62. Extract from the online catalog. Order No.:

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

HERZ-Thermal Actuators

3-Component Measuring System

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Current Transformers

R.C.C.B. s two-pole LEXIC

SURGE PROTECTIVE DEVICES

BETA Protecting SITOR Semiconductor Fuses

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Medium voltage product. Instrument transformers for indoor applications Product overview

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

SMS 4 / SMS 5 safety mat Product information

Product Information Sheet UH36 Hi Pot Tester

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

3-phase, bidirectional energy meter

Tape Wound, Split Core and Ebony Current Transformers

MINI MCR-SL-R-UI(-SP)

Feed-through terminal block - SSK 110 KER-EX

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

DS 600. A contact free flux gate based current measurement sensor 600A rms

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Kit Watt Audio Amplifier

Voltage Regulator SPAU 341 C. Product Guide

Technical data UNIBLOCK UBSF

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safety Relays ESM/ESM-F

Instruction Manual Differential Pressure Transmitter

A good connection. International approvals.

SECTION DRY-TYPE TRANSFORMERS

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

Current transformer selection guide

Presentation of the France Transfo factories

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

PC 4/ 2-ST-7,62. Extract from the online catalog. Order No.:

Terminal Boxes Series 8146

Guidance for upgrading to GB (IEC : 2005, MOD)

Contact expander modules

3/2- and 2/2-way cartridge valve type BVE

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

Z-TRAUQ INC. Tel.: (450) Fax: (450)

5.2. Overview. The better method to install solderless compression connectors on power cable

Current and voltage measuring relays

Operating Instructions for Plastic Flow Meter. Model: KSK

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

Contact expansion modules

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

0.84" x 2.00" Z-TRAUQ INC. Tel.: (450) Fax: (450) z-trauq@qc.aira.com SPLIT CORE CURRENT TRANSFORMER MODEL 1SP.

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Low Voltage Switchboards The Best Technical Solution for Your Ship

Electronic overload relay EF19 and EF45

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Transformer Bushings for GIS

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

Pluggable interface relays CR-P Pcb relays

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Thyristor-controlled power supplies and battery chargers

How To Read A Pipe From A Sensor

13 SERIES. Electronic step relays A

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Transcription:

Medium-voltage transformers We make energy measurable and take care of your future www.mbs-ag.com

Page 2 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Contents Current transformers Technical characteristics From page 4 Medium-voltage current transformers for indoor usage From page 8 Support type current transformer 7.2 kv; 12 kv; 17.5 kv Page 8 Narrow type according DIN 42600, part 8 Support type current transformer, primary switchable 7.2 kv; 12 kv; 17.5 kv Page 10 Narrow type according DIN 42600, part 8 Support type current transformer 7,2 kv; 12 kv; 17.5 kv Page 12 Support type current transformer 24 kv Page 14 Narrow type according DIN 42600, part 8 Split-core current transformer, fully resin hardened for indoor applications Split-core current transformer 0.72 kv / 1.2 kv Page 16 Tube current transformer, fully resin hardened for indoor applications Single-piece tube current transformer 0.72 kv / 1.2 kv Page 18 Single-piece tube current transformer 0.72 kv Page 20 Single- and double pole insulated medium-voltage voltage transformers for indoor applications Voltage transformers 7.2 kv; 12 kv; 17.5 kv; 24 kv Narrow, small and large type acc. DIN 42600-9; resp. part 7 or 3 Page 22 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 3

Current transformers Technical characteristics Current transformers are special transformers for the proportional transformation of high currents into directly measurable values. Their construction and physical operating principle enables a galvanic separation of the primary circuit from the measured circuit, thereby providing a protection for sequentially connected instruments in the event of a fault. Primary nominal current Secondary nominal current Actual transformation ration Burden Rated burden Rated power Nominal frequency Accuracy class Phase displacement error [Δφ] Current error (Transmission error) Value of the primary current, that characterises the current transformer and for which it is designed. Value of the secondary current, that characterises the current transformer and for which it is designed. Is the ratio of the primary nominal current to the secondary nominal current. It is specified as an unabridged break on the rating plate. The impedance of the secondary current is declared in ohms and power factor. The burden is usually expressed as the apparent power in volt-amperes, absorbed at a specified power factor and at the rated secondary current. The value of the burden upon which the accurate requirements of this specification are based. The value of the apparent power (in a VA specified power factor), which the current transformer is intended to supply to the secondary circuit and rated burden at the rated secondary current. Value of the frequency, on which the calculation of the current transformer is based. The denotation for a current transformer whose measuring deviation remains below the prescribed operating condition. Signifies the phase shift of the primary current and the secondary current. The direction of the indicator is arranged in such a way, that with an optimum produced current transformer the phase displacement error is equal to zero. The phase displacement error is to be regarded as positive when the indicator of the secondary current is ahead compared to the indicator of the primary current. The phase displacement error is specified in minutes or hundredths of a radiant. Note: Strictly speaking this definition is only valid for sinus type currents. Is the percentage deviation of the nominal transmission multiplied by the secondary current from that of the primary current. The current error is calculated positively, should the actual value of the secondary current exceed the nominal value. F i = Current error in % K n = Rated measuring ratio I p = Primary current in A (effective value) = Secondary current in A (effective value) I s Max. voltage for electrical equipment U m This denotes the highest constant permitted value for phase to phase voltage for which the current transformers isolation is rated. Page 4 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Total measuring deviation Is the effective value in stationary position, and the difference between: a) The momentary value of the primary current and b) The momentary value of the measuring transmission of the multiplied actual secondary current, whereby the positive indicators of the primary and secondary current correspond to the accord for the connection denotation. The total measuring deviation F g is generally rendered in the percentages of the effective value of the primary current, as per the following mathematical equation: K n = Rated measuring transmission I p = Effective value of the primary current i p = Momentary value of the primary current i s = Momentary value of the secondary current T = Duration of period Rated limit current [I pl ] Over-current rated limiting factor (FS) Thermal rated continuous rated current [I cth ] Thermal rated short-time current [I th ] Rated surge current [I dyn ],,Open circuit voltage of current transformers Earthing of secondary terminals Value of the lowest primary current where, by the secondary measuring burden, the total deviation of the current transformer for measuring purposes is equal to or greater than 10%. Is the ratio of the limit rated current to the primary rated current. Is the primary current which allows the continuous operation of the current transformer. When using this current value, the temperature of the secondary wiring must not exceed the prescribed values mentioned in the actual technical norms. This value is in direct relation to the isolation material class. This value indicates the effective value of the primary current which the current transformers can withstand with short circuited secondary winding. Other rated measuring values as 1s, e.g. 0.5s, 2s and 3s are acceptable. The thermal short time rated current I th has to be stated for each current transformer. Peak value of the primary current, whose electro-mechanical impact is resisted by the current transformer with short circuited secondary winding. Current transformers, which are not directly encumbered with a burden, have to be generally secondarily short circuited! A secondary open current transformer operates like a loaded one with an almost infinitely high burden. The curve shape of the secondary current is extremely deformed and under certain conditions voltage surges occur up to several kilovolts, which can be harmful to human beings. The amount of the induced loss motion depends on the core cross-section and the number of secondary turns. According to DIN VDE 0141 (01/2000), section 5.3.4, current- and voltage transformers have to be secondarily earthed, starting from U m = 3.6 kv. The design of the earthing connections are mandatory up from series 10N. E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 5

Error limits for measuring transformers for classes 0.2 3 according to DIN EN 61869, part 1 + 2 (former DIN EN 60044-1) Current error ± F by Phase displacement error ± F by Accuracy class 1.2 I n 1.0 I n 0.5 I n 0.2 I n 0.05 I n 0.01 I n 1.2 I n 1.0 I n 0.5 I n 0.2 I n 0.05 I n 0.01 I n % % % % % min min min min min 0.2S 0.2 0.2 0.35 0.75 10 10 15 30 0.2 0.2 0.35 0.75 10 15 30 0.5S 0.5 0.5 0.75 1.5 30 30 45 90 0.5 0.5 0.75 1.5 30 45 90 1 1 1.5 3 60 90 180 3 3 3 Error limit values for current transformers for protection applications Current error ± F i by Phase displacement error ± F i by Accuracy class 1.0 I n 1.0 I n and thermal nominal continuous current and thermal nominal continuous current % min 5 P 1 60 10 P 3 Current error F g at nominal error current limit and nominal burden Class 5P 5 % Class 10P 10 % Partial discharges Partial discharge requirements are valid for instrument transformers with U m 7.2 kv. Partial discharge test voltages and permissible levels Type of system earthing Partial discharge test voltage (Effective value) kv Permissible partial discharge level 2) pc Type of insulation liquid insulation solid insulation Star point grounded 1) (Earth fault 1.5) Star point isolated or not effectively grounded 1) (Earth fault > 1.5) U m 1.2 U m / 3 1.2 U m 1.2 U m / 3 1) If the type of system earthing is not mentioned, the values for the isolated or not effectively grounded star point are has to be taken. 2) The permissible partial discharge levels are also applicable for frequencies deviating from the nominal rated frequency. 10 5 10 5 50 20 50 20 Page 6 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Markings of the current transformers connection terminals The connections of all primary windings are marked with capital letters P1 and P2. The connections of all secondary windings are marked with the corresponding lower case letters s1 and s2. Power requirements of measuring setups Two main requirements are cited by the user for the principle demands of current transformers: - a high degree of measuring precision in the range of the nominal current - a protection function in the over-load range In order to fulfil these demands it is necessary for the assumed nominal power of a current transformer to fully achieve the actual power requirements of the prescribed measurements. In ascertaining the actual power requirements, consideration is to be given to the power losses of the appliances to be connected, as well as to the losses of the measuring conductor. The actual power consumption of the connected devices can be found in the respective data sheets. Please note: If the power requirement of the measuring setup is substantially less than the power supply of the current transformer, the CT loses his protective function in over-current ranges. In some cases this can lead to a damage of the connected devices. Power consumption of copper wires I s = Secondary nominal current [A] I = Distance in m A cu = Wire cross section in mm² P v = Power loss of the measuring conductor Comment: With a joint three phase current return conductor the values of P v are halved. Chart for values referring to 5 A Nominal cross section 1 m 2 m 3 m 4 m 5 m 6 m 7 m 8 m 9 m 10 m 2.5 mm² 0.36 0.71 1.07 1.43 1.78 2.14 2.50 2.86 3.21 3.57 4.0 mm² 0.22 0.45 0.67 0.89 1.12 1.34 1.56 1.79 2.01 2.24 6.0 mm² 0.15 0.30 0.45 0.60 0.74 0.89 1.04 1.19 1.34 1.49 10.0 mm² 0.09 0.18 0.27 0.36 0.44 0.54 0.63 0.71 0.80 0.89 Chart for values referring to 1 A Nominal cross section 10 m 20 m 30 m 40 m 50 m 60 m 70 m 80 m 90 m 100 m 1.0 mm² 0.36 0.71 1.07 1.43 1.78 2.14 2.50 2.86 3.21 3.57 2.5 mm² 0.14 0.29 0.43 0.57 0.72 0.86 1.00 1.14 1.29 1.43 4.0 mm² 0.09 0.18 0.27 0.36 0.45 0.54 0.63 0.71 0.80 0.89 6.0 mm² 0.06 0.12 0.18 0.24 0.30 0.36 0.42 0.48 0.54 0.60 10.0 mm² 0.04 0.07 0.11 0.14 0.18 0.21 0.25 0.29 0.32 0.36 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 7

Support type current transformers for indoor application 7.2 kv, 12 kv and 17.5 kv Narrow type according to DIN 42600, part 8 Description: Medium-voltage current transformers for indoor application, which are converting multiple primary currents proportional and in-phase into measurable and standardized secondary currents. These transformers are fully resin-hardened in polyurethane and are serving apart of their main function as a current transformer as well as a bus bar support. These CTs are both applicable for measuring as well as for protection purposes. When ordering the selection has to be made. The medium-voltage current transformers are also available as multicore current transformers. The maximum quantity of cores depends on the chosen burden and accuracy class. Technical data: CTS7.2M11 CTS12M11 CTS17.5M11 Max. operating voltage U m: 7.2 kv 12 kv 17.5 kv Power frequency voltage: 20 kv 28 kv 38 kv Lightning impulse voltage: 60 kv 75 kv 95 kv Therm. nominal continuous rated current I cth: 1.2 x I N 1.2 x I N 1.2 x I N Therm. rated short-time current I th: 31.5 ka, 1 sec. 31.5 ka, 1 sec. 31.5 ka, 1 sec. Rated surge current I dyn: 2.5 x I th 2.5 x I th 2.5 x I th Primary nominal current: 25 A 2500 A 25 A 2500 A 25 A 2500 A Secondary nominal current: 5 A or 1 A 5 A or 1 A 5 A or 1 A Nominal frequency: 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Measuring CT accuracy classes: 1; 0.5; 0.5S; 0.2; 0.2S 1; 0.5; 0.5S; 0.2; 0.2S 1; 0.5; 0.5S; 0.2; 0.2S Protection CT accuracy classes: 5P5; 5P10; 5P20; 5P30; 5P5; 5P10; 5P20; 5P30; 5P5; 5P10; 5P20; 5P30; 10P5; 10P10; 10P20; 10P30 10P5; 10P10; 10P20; 10P30 10P5; 10P10; 10P20; 10P30 Insulation class: E E E Cantilever strength: 5000 Nm 5000 Nm 5000 Nm Weight: approx. 22 kg approx. 22 kg approx. 22 kg Subject to technical modifications without notice Please note, that the above mentioned data are standard values. Other values on request. Page 8 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Drawings: Legende: 1 Cast resin housing Primary connection M12x23, screws M12x25 (Please note: The primary connection is also available with a hole spacing of 40mm instead 2 of 32mm.) 3 Rating plate 4 Danger sign 5 Transparent terminal cover 6 Cable gland PG16 (Please note: On request the cable gland is also available with thread M20x1.5) 7 Max. 6 secondary terminals M5x10, screws M5x12 8 Secondary earthing screws, red, M5x15 9 Fixing screws of terminal cover (sealable only when calibration is required) 10 Base plate 11 Earthing connection screw M8x16 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 9

Primary switchable support type current transformers for indoor application 7.2 kv, 12 kv and 17.5 kv Narrow type according to DIN 42600, part 8 Description: Medium-voltage transformers for indoor application, which are converting multiple primary currents proportional and in-phase into measurable and standardized secondary currents. These transformers are fully resin-hardened in polyurethane and are serving apart of their main function as a current transformer as well as a bus bar support. These CTs are both applicable for measuring as well as for protection purposes. When ordering the selection has to be made. The medium-voltage current transformers are also available as multicore current transformers. The maximum quantity of cores depends on the chosen burden and accuracy class. With the current transformers, which are primary switchable you have the possiblity to chose two different primary nominal currents. The selection can be made depending on the connection, if connected in parralel or series. The primary nominal currents can only be realized in transmission 1:2. Technical data: CTS7.2M11U CTS12M11U CTS17.5M11U Max. operating voltage U m: 7.2 kv 12 kv 17.5 kv Power frequency voltage: 20 kv 28 kv 38 kv Lightning impulse voltage: 60 kv 75 kv 95 kv Therm. nominal continuous rated current I cth: 1.2 x I N 1.2 x I N 1.2 x I N Therm. rated short-time current I th: 31.5 ka, 1 sec. 31.5 ka, 1 sec. 31.5 ka, 1 sec. Rated surge current I dyn: 2,5 x I th 2,5 x I th 2,5 x I th Primary nominal current: 25-50 A 600-1200 A 25-50 A 600-1200 A 25-50 A 600-1200 A Secondary nominal current: 5 A or 1 A 5 A or 1 A 5 A or 1 A Nominal frequency: 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Measuring CT accuracy classes: 1; 0.5; 0.5S; 0.2; 0.2S 1; 0.5; 0.5S; 0.2; 0.2S 1; 0.5; 0.5S; 0.2; 0.2S Protection CT accuracy classes: 5P5; 5P10; 5P20; 5P30; 5P5; 5P10; 5P20; 5P30; 5P5; 5P10; 5P20; 5P30; 10P5; 10P10; 10P20; 10P30 10P5; 10P10; 10P20; 10P30 10P5; 10P10; 10P20; 10P30 Insulation class: E E E Cantilever strength: 5000 Nm 5000 Nm 5000 Nm Weight: approx. 22 kg approx. 22 kg approx. 22 kg Subject to technical modifications without notice Please note, that the above mentioned data are standard values. Other values on request. Page 10 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Drawings: Terminal assignment: Key: 1 Cast resin housing Primary connection M12x23, screws M12x25 (Please note: The primary connection is also available with a hole spacing of 40mm instead 2 of 32mm.) 3 Primary re-connection 4 Rating plate 5 Danger sign 6 Transparent terminal cover 7 Cable gland PG16 (Please note: On request the cable gland is also available with thread M20x1.5) 8 Max. 6 secondary terminals M5x10, screws M5x12 9 Secondary earthing screws, red, M5x15 10 Fixing screws of terminal cover (sealable only when calibration is required) 11 Base plate 12 Earthing connection screw M8x16 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 11

Support type current transformers for indoor application 7.2 kv, 12 kv and 17.5 kv Description: Medium-voltage transformers for indoor application, which are converting multiple primary currents proportional and in-phase into measurable and standardized secondary currents. These transformers are fully resin-hardened in polyurethane and are serving apart of their main function as a current transformer as well as a bus bar support. These CTs are both applicable for measuring as well as for protection purposes. When ordering the selection has to be made. The medium-voltage current transformers are also available as multicore current transformers. The maximum quantity of cores depends on the chosen burden and accuracy class. Technical data: CTS7.2M12 CTS12M12 CTS17.5M12 Max. operating voltage U m: 7.2 kv 12 kv 17.5 kv Power frequency voltage: 20 kv 28 kv 38 kv Lightning impulse voltage: 60 kv 75 kv 95 kv Therm. nominal continuous rated current I cth: 1,2 x I N 1,2 x I N 1,2 x I N Therm. rated short-time current I th: 31.5 ka, 1 sec. 31.5 ka, 1 sec. 31.5 ka, 1 sec. Rated surge current I dyn: 2.5 x I th 2.5 x I th 2.5 x I th Primary nominal current: 1500 A 3000 A 1500 A 3000 A 1500 A 3000 A Secondary nominal current: 5 A or 1 A 5 A or 1 A 5 A or 1 A Nominal frequency: 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Measuring CT accuracy classes: 1; 0.5; 0.5S; 0.2; 0.2S 1; 0.5; 0.5S; 0.2; 0.2S 1; 0.5; 0.5S; 0.2; 0.2S Protection CT accuracy classes: 5P5; 5P10; 5P20; 5P30; 5P5; 5P10; 5P20; 5P30; 5P5; 5P10; 5P20; 5P30; 10P5; 10P10; 10P20; 10P30 10P5; 10P10; 10P20; 10P30 10P5; 10P10; 10P20; 10P30 Insulation class: E E E Cantilever strength: 5000 Nm 5000 Nm 5000 Nm Weight: approx. 25 kg approx. 25 kg approx. 25 kg Subject to technical modifications without notice Please note, that the above mentioned data are standard values. Other values on request. Page 12 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Drawings: Legende: 1 Cast resin housing Primary connection M12x23, screws M12x25 (Please note: The primary connection is also available with a hole spacing of 40mm instead 2 of 32mm.) 3 Rating plate 4 Danger sign 5 Transparent terminal cover 6 Cable gland PG16 (Please note: On request the cable gland is also available with thread M20x1.5) 7 Max. 6 secondary terminals M5x10, screws M5x12 8 Secondary earthing screws, red, M5x15 9 Fixing screws of terminal cover (sealable only when calibration is required) 10 Base plate 11 Earthing connection screw M8x16 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 13

Support type current transformers for indoor application 24 kv Narrow type according to DIN 42600, part 8 Description: Medium-voltage transformers for indoor application, which are converting multiple primary currents proportional and in-phase into measurable and standardized secondary currents. These transformers are fully resin-hardened in polyurethane and are serving apart of their main function as a current transformer as well as a bus bar support. These CTs are both applicable for measuring as well as for protection purposes. When ordering the selection has to be made. The medium-voltage current transformers are also available as multicore current transformers. The maximum quantity of cores depends on the chosen burden and accuracy class. Technical data: CTS24M32 Max. operating voltage U m: 24 kv Power frequency voltage: 50 kv Lightning impulse voltage: 125 kv Therm. nominal continuous rated current I cth: 1.2 x I N Therm. rated short-time current I th: 31.5 ka, 1 sec. Rated surge current I dyn: 2.5 x I th Primary nominal current: 25 A 3000 A Secondary nominal current: 5 A or 1 A Nominal frequency: 50 / 60 Hz Measuring CT accuracy classes: 1; 0.5; 0.5S; 0.2; 0.2S Protection CT accuracy classes: 5P5; 5P10; 5P20; 5P30; 10P5; 10P10; 10P20; 10P30 Insulation class: E Cantilever strength: 5000 Nm Weight: approx. 28 kg Subject to technical modifications without notice Please note, that the above mentioned data are standard values. Other values on request. Page 14 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Drawings: Key: 1 Cast resin housing Primary connection M12x23, screws M12x25 (Please note: The primary connection is also available with a hole spacing of 40mm instead 2 of 32mm.) 3 Rating plate 4 Danger sign 5 Transparent terminal cover 6 Cable gland PG16 (Please note: On request the cable gland is also available with thread M20x1.5) 7 Max. 6 secondary terminals M5x10, screws M5x12 8 Secondary earthing screws, red, M5x15 9 Fixing screws of terminal cover (sealable only when calibration is required) 10 Base plate 11 Earthing connection screw M8x16 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 15

CTO Split-core current transformer, fully resin-hardened for indoor applications 0.72 kv / 1.2 kv Features / Benefits - Split-core current transformer suitable for measuring or protection purposes, depending on the design of the CT - The modular design of this series allows a large number of varieties within the different CT sizes (f.e. two cores in one unit); please see next page for details about the different dimensions - Max. operating voltage: 0.72/3/- kv or 1.2/6/- kv; if the primary conductor is suitably insulated the CT can also be used above 0.72 kv or 1.2 kv - Primary current range: 50 A 5000 A - Secondary currents: 1 A, 2 A or 5 A - Rated burden: 2.5 VA 30 VA - Accuracy classes: 0.2S; 0.2; 0.5S; 0.5; 1; 3 - Over-current rated limiting factor for measuring cores: FS5 or FS10 - Protection classes: 5P / 10P / PX - Over-current rated limiting factor for protection cores: 5, 10, 15, 20, 30 Dimensions: Primary opening diameter: max. 360 mm Transformer width: 150-500 mm Transformer depth: 60-300 mm Please see next page for details about the different dimensions. General technical specifications: Therm. nominal continuous rated current I cth : 1,0 x I N or 1,2 x I N, other values upon request Therm. nominal short-time current I th : Min. 100 x I N / 1 sec., other values upon request Rated dynamic current I dyn : 2,5 x I th Max. operating voltage U m : 0,72 kv or 1,2 kv Isolation test voltage: 3 kv, U eff, 50 Hz, 1 min. or 6 kv, U eff, 50 Hz, 1 min. Rated frequency: 50 Hz or 60 Hz, other values upon request Isolation class: E Applicable technical standards: DIN EN 61869, part 1 + 2 (formerly DIN EN 60044-1) Further information: Measuring systems fully hardened with Polyurethane resin The current transformers type CTO are intended for subsequent installation in existing low-voltage switchgear. In addition, there are customers who use these current transformers in medium-voltage switchgears, if the primary conductor is suitably insulated. Further applications are wind turbines, facilities for power generation on ships, power distribution systems, etc. The two parts of the current transformer are held together by four screws with springs or spring clips on the sides, which ensures a permanent contact pressure. The secondary connection terminals are factory-fitted with M5 screws. A clear plastic cover serves as an touch protection. Protection type: Housing: IP54, Terminal cover: IP20 Operating temperature: -5 C < T < +40 C Storage temperature: -25 C < T < +70 C Mounting of CT by means of a baseboard attached to the resin body Packaging unit: 1 Stk. Customs tariff number: 85043129 Page 16 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Dimension drawings: Frame size x* y* A 60 25 B 90 55 C 120 85 D 150 115 E 200 165 F 250 215 G 300 265 * Dimension x + y depends on the type and number of measuring systems installed. Determination of current transformer type: Example: CTO 200 B 130 Inner diameter (d1: 130 mm) Frame size (B: 90 mm) CT type: CTO 200 CT type b1 b2 b3 max. d1 d2 h1 h2 h3 max. frame size Deliverable CTO 135 135 150 130 90 9 150 75 10 C Upon request CTO 150 150 150 130 110 9 165 82.5 10 D Upon request CTO 170 170 170 150 110 11 185 97.5 10 D Yes CTO 200 200 200 180 140 11 220 110 10 E Yes CTO 250 250 250 230 150 11 270 135 10 E Yes CTO 300 300 300 280 210 11 330 165 10 F Upon request CTO 350 350 350 330 250 11 380 190 10 F Upon request CTO 400 400 400 370 300 13 430 215 15 G Upon request CTO 500 500 500 440 360 13 530 265 15 G Upon request E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 17

CTR Single-piece current transformers, fully resin-hardened for indoor applications 0.72 kv / 1.2 kv Features / Benefits - Single-piece current transformer suitable for measuring or protection purposes, depending on the design of the CT - The modular design of this series allows a large number of varieties within the different CT sizes (f.e. two cores in one unit); please see next page for details about the different dimensions - Max. operating voltage: 0.72/3/- kv or 1.2/6/- kv; if the primary conductor is suitably insulated the CT can also be used above 0.72 kv or 1.2 kv - Primary current range: 50 A 5000 A - Secondary currents: 1 A, 2 A or 5 A - Rated burden: 2.5 VA 30 VA - Accuracy classes: 0.2S; 0.2; 0.5S; 0.5; 1; 3 - Over-current rated limiting factor for measuring cores: FS5 or FS10 - Protection classes: 5P / 10P / PX / TPS / TPY - Over-current rated limiting factor for protection cores: 5, 10, 15, 20, 30 Dimensions: Primary opening diameter: max. 360 mm Transformer width: 100-500 mm Transformer depth: 60-300 mm Please see next page for details about the different dimensions. General technical specifications: Therm. nominal continuous rated current I cth : 1,0 x I N or 1,2 x I N, other values upon request Therm. nominal short-time current I th : Min. 100 x I N / 1 sec., other values upon request Rated dynamic current I dyn : 2,5 x I th Max. operating voltage U m : Isolation test voltage: 0,72 kv or 1,2 kv 3 kv, U eff, 50 Hz, 1 min. or 6 kv, U eff, 50 Hz, 1 min. Rated frequency: 50 Hz or 60 Hz, other values upon request Isolation class: E Applicable technical standards: DIN EN 61869, part 1 + 2 (formerly DIN EN 60044-1) Further information: Measuring systems fully hardened with Polyurethane resin The current transformers type CTR are intended for installation in low-voltage switchgear. In addition, there are customers who use these current transformers in medium-voltage switchgears, if the primary conductor is suitably insulated. Further applications are wind turbines, facilities for power generation on ships, power distribution systems, etc. The current transformers are manufactured in a standard version with a round window opening. But optionally a rectangular window opening for bus bar mounting is possible to produce. The secondary connection terminals are factory-fitted with M5 screws. A clear plastic cover serves as an touch protection. Protection type: Housing: IP54, Terminal cover: IP20 Operating temperature: -5 C < T < +40 C Storage temperature: -25 C < T < +70 C Mounting of CT by means of a baseboard attached to the resin body (optionally: frontal threaded bushes) Packaging unit: 1 Stk. Customs tariff number: 85043129 Page 18 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Dimension drawings: Frame size x* y* A 60 25 B 90 55 C 120 85 D 150 115 E 200 165 F 250 215 G 300 265 * Dimension x + y depends on the type and number of measuring systems installed. Determination of current transformer type Example: CTR 200 B 130 Inner diameter (d1: 130 mm) Frame size (B: 90 mm) CT type: CTR 200 CT type b1 b2 b3 max. d1 d2 h1 h2 h3 max. frame size Deliverable CTR 100 100 100 80 60 9 110 55 5 C Upon request CTR 110 110 110 90 70 9 120 60 5 C Upon request CTR 120 120 120 100 75 9 130 65 5 C Upon request CTR 135 135 150 130 90 9 150 75 10 C Yes CTR 150 150 150 130 110 9 165 82,5 10 D Yes CTR 170 170 170 150 110 11 185 97,5 10 D Yes CTR 200 200 200 180 140 11 220 110 10 E Yes CTR 250 250 250 230 150 11 270 135 10 E Upon request CTR 300 300 300 280 210 11 330 165 10 F Upon request CTR 350 350 350 330 250 11 380 190 10 F Upon request CTR 400 400 400 370 300 13 430 215 15 G Upon request CTR 500 500 500 440 360 13 530 265 15 G Upon request E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 19

ASG 106 Tube current transformer, fully resin-hardened for indoor applications 0.72 kv Features / Benefits - Tube current transformer with up to 4 measuring systems integrated in one housing - Combination of measuring and protection transformers in one housing is possible - Max. operating voltage: 0.72/3/- kv; if the primary conductor is suitably insulated the CT can also be used above 0.72 kv - Primary current range: 40 A 1250 A - Secondary currents: 1 A, 2 A or 5A - Rated burden: 2.5 VA 30 VA - Accuracy classes: 0.2S; 0.2; 0.5S; 0.5; 1; 3 - Over-current rated limiting factor for measuring cores: FS5 or FS10 - Protection classes: 5P / 10P / PX - Over-current rated limiting factor for protection cores: 5, 10, 15, 20, 30 Dimensions: Primary opening diameter: 106 mm Transformer width: 190 mm Transformer depth: 50, 100, 170, 214 mm* Please see next page for details about the different dimensions. General technical specifications: Therm. nominal continuous rated current I cth : 1.2 x I N, other values upon request Therm. nominal short-time current I th : 25 ka / 3 sec., other values upon request Rated dynamic current I dyn : 2.5 x I th Max. operating voltage U m : 0.72 kv Isolation test voltage: 3 kv, U eff, 50 Hz, 1 min. Rated frequency: 50 Hz, other values upon request Isolation class: F Applicable technical standards: DIN EN 61869, part 1 + 2 (formerly DIN EN 60044-1) Weitere Informationen: Measuring systems fully hardened with Polyurethane resin Full resin hardening and the used high-quality materials allow the application under extreme mechanical and climatic conditions (f.e. application close to generator) Resin material with high fire safety (UL94-V0) Current transformer type tested by Siemens AG The current transformers type ASG 106 are intended for installation in low-voltage switchgear. In addition, there are customers who use these current transformers in medium-voltage switchgears, if the primary conductor is suitably insulated. Further applications are wind turbines, facilities for power generation on ships, power distribution systems Measuring cores with PTB approval available 4 different housing depths allow the realisation of different customer requirements Reduction of external wiring by means of flexible secondary connection cables (3.6 m, 4 mm², other lengths and profiles upon request) Flexible terminal connections are protected by additional textile braided sleeving. Influence of cable length is taken into account in the interpretation of the measurement systems Operating temperature: -5 C < T < +60 C Storage temperature: -25 C < T < +70 C Housing material: ABS, self-extinguishing, UL94-V0 Mounting of current transformers by with 2 pieces (optional 4 pieces) hexagon bolts M8x30 Packaging unit: 1 pc. Customs tariff number: 85043129 Page 20 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Measurements: Housing depth x* 50 mm 100 mm 170 mm 214 mm Measurement y (optional!) - 85 mm 155 mm 199 mm * Dimension x + y depends on the type and number of measuring systems installed. E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 21

Voltage transformers for indoor usage 7.2 kv; 12 kv; 17.5 kv and 24 kv Narrow, small and large type according DIN 42600, part 9; resp. part 7 or part 3 In addition to our medium-voltage current transformers, we are also able to provide voltage transformers for voltage levels up from 7.2 kv to 24 kv upon request. They are available both single-pole and double-pole insulated and can be used for measuring and protection purposes. For the single-pole insulated voltage transformers, there is also the possibility to provide them with an additional winding for earth-fault detection. Thereby we cover the complete range of typical demands for medium-voltage switchgears. Page 22 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com

Your inquiry / order: Company: Address: Contact name: Telephone number: Email address: Inquiry Order Pos. 1 Pos. 2 Pos. 3 Quantity: Ratio: Core 1 (Burden and accuracy class): Core 2 (optional) (Burden and class): Core 3 (optional) (Burden and class): Insulation level (z.b.12/28/75kv): Values, which differ from our standard values mentioned in the data-sheets, please indicate below: (f.e. therm. rated short-time current I th of 20 ka instead of 31.5 ka; Frequency of 60 Hz instead of 50 Hz etc.) E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Page 23

Current transformers for industry Current transformers for tariff Accessories for current transformers Medium-voltage CTs Bus bar insulators / -supports Shunts Voltage transformers All current sensors Measuring transducers Energy meters for industry Energy meters for tariff Panel board heaters, filter fans, roof fans and control units www.mbs-ag.com Eisbachstraße 51 74429 Sulzbach-Laufen Telefon: +49 7976 9851-0 Telefax: +49 7976 9851-90 info@mbs-ag.com www.mbs-ag.com MBS IDNR 8.4.0362/1000/3-2013