Casement and Awning Window Casement Low maintenance exterior Easy to operate Slim frame and sash profile maximize the field of view Excellent for creating window combinations, as well as bays and bows Awning Contents Casement Window Basic Unit Details - Single Sash Units...1-2 Basic Unit Details - Double Sash Units...1-3 Basic Unit Details - Picture Unit...1-4 Options / Accessories Extension s...1-4 Grilles...1-5 Vent Limiter...1-7 Joining Details...1-8 Anchoring Methods... 1-10 Suggested Product Applications... 1-11 Awning Window Basic Unit Details - Single Sash Unit... 1-13 Basic Unit Details - Picture Unit... 1-14 Options / Accessories Extension s... 1-14 Grilles... 1-15 Extension Arm Pack... 1-17 Vent Limiter... 1-18 Operators... 1-20 Joining Details... 1-21 Anchoring Methods... 1-23 Suggested Product Applications... 1-24 A R C H I T E C T U R A L D E T A I L F I L E 1-1
Basic Unit Details - Single Sash Units Basic Unit Casement and Awning Window 1-5/16" (33) 2-7/8" (73) 2-13/32" (61) extension jambs 1-1/8" (29) 1-3/16" (30) low profile stop, for CW135 and CW235 size units. Glass Height High-Performance insulating glass insect screen Clear Opening Height Low Profile Stop 2-13/32" (61) 1-7/16" (37) 1-1/8" (29) Stationary 1-1/8" 15/16" (29) (24) extension jambs insect screen 2-7/8" (72) 1-5/16" (33) 2-3/16" (56) Glass 2-3/16" (56) Unit Dimension Rough Opening 1-2 A R C H I T E C T U R A L D E T A I L F I L E
Casement and Awning Window Basic Unit Details - Double Sash Units Basic Unit 1-5/16" (33) 2-7/8" (73) 2-13/32" (61) extension jambs 1-1/8" (29) 1-3/16" (30) Glass Height High-Performance insulating glass insect screen Clear Opening Height 2-13/32" (61) 1-7/16" (37) 1-1/8" (29) 1-1/8" 15/16" (29) (24) 15/16" (24) 2" (51) extension jambs insect screen 2-7/8" (72) 1-5/16" (33) Mullion Unit Dimension Rough Opening High-Performance insulating glass A R C H I T E C T U R A L D E T A I L F I L E 1-3
Casement and Awning Window Basic Unit Details - Picture Unit (P) Basic Unit 1-5/16" (33) 2-7/8" (72) 1-1/8" (29) 1-3/16" (30) extension jambs extension jambs 2-3/8" (60) 1-1/8" (29) 1-3/16" (30) 2-7/8" (72) High-Performance insulating glass Rough Opening Unit Dimension 2-3/8" (60) Glass Height 1-3/16" (30) 1-1/8" (29) 1-5/16" (33) 2-3/8" (60) Glass 2-3/8" (60) Unit Dimension Rough Opening Options / Accessories Extension s 1/8" (3) Drywall return Face: 4-9/32" (109) 7-1/8" Wall Face: 3-23/32" (95) 6-9/16" Wall Face: 2-13/32" (61) 11/16" (17) 5- Wall 4-9/16" Wall Face: 1-23/32" (44) 4-9/16" (116) 5- (133) 6-9/16" (167) 7-1/8" (181) Extension jambs available for 4-9/16" (116), 5- (133), 6-9/16" (167) or 7-1/8"(181) wall thickness. Other wall dimensions can be accommodated with extension jamb modification. 6-9/16" (167) extension jamb is predrilled for easy application. Rough Opening 1-4 A R C H I T E C T U R A L D E T A I L F I L E
Casement and Awning Window Options / Accessories Divided Light Grilles Available now Available only with 3/8" glass through the Andersen Divided Light program Please check with Andersen for availability Casement & Awning Casement Picture Window Gliding Window Woodwright Double-Hung & Transom Woodwright Picture Window Woodwright Archtop & Unequal Leg Archtop Andersen 400 Series Windows Woodwright Springline Single-Hung Tilt-Wash Double-Hung & Transom Tilt-Wash Picture Window Circle Top & Quarter Round Arch Springline Flexiframe Elliptical Circle & Oval Gothic 200 Series Narroline Double-Hung & Transom Andersen 400 Series Doors Frenchwood Gliding Frenchwood Hinged Inswing Frenchwood Hinged Outswing Frenchwood Patio Door Sidelights & Transoms Glass Patterns Interior Type Exterior Color White Sandtone Terratone Forest Green 3/4" 7/8" 1-1/8" 2- With Spacer Without Spacer Maple Oak Prefinished Pine Colonial Modified Colonial Modified Col W/Check Rail Prairie A Short Fractional Short Fractional W/Check Rail Tall Fractional Tall Fractional W/Check Rail Victorian Renaissance Sunburst Specified Equal Light Custom HP/HP Tempered HP Sun/HP Sun Temp 3/8" Low-E/Temp Single-Pane Impact A R C H I T E C T U R A L D E T A I L F I L E 1-5
Casement and Awning Window Options / Accessories 400 Series Grille Options Andersen Divided Light Grille Permanent Exterior Permanent Interior with Spacer Andersen Divided Light Grille Permanent Exterior Permanent Interior Andersen Divided Light Grille Permanent Exterior Removable Interior Removable Interior Andersen Finelight Grilles-Between-the-Glass Grille Profiles Scale = Full Dimensions include thickness of tape. Permanent Exterior Fibrex Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright double-hung windows. 5/16" 7/16" 1/2" 1-13/16" 45 45 35 45 5/16" 5/16" 5/16" 5/16" 3/4" 7/8" 1-1/8" 2- Permanent Interior Wood Grille Profiles (chamfer profile). The Fibrex material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright double-hung windows. 1/2" 1-13/16" 5/16" 7/16" 3/8" 53 3/8" 53 3/8" 35 7/16" 53 3/32" 7/8" 3/4" 1-1/8" 2- Removable Interior Wood Grille Profile (roman ogee profile). Removable Interior Wood Grille Profile (Chamfer profile). 400 Series Woodwright double-hung windows only. 1/2" 7/16" 3/4" 7/8" 1-1/8" 3/4" 7/8" 1-1/8" Permanent Full Divided Light Grille spacer location. 1/2" 1/2" 1/2" 1/2" 1/2" 1/8" 3/16" 5/16" 1/8" Andersen Finelight Grilles-Between-the-Glass. 1-6 3/8" 3/4" 1/2" 1" A R C H I T E C T U R A L D E T A I L F I L E
Casement and Awning Window Options / Accessories Casement Vent Limiter Scale: None Split arm vent limiters are available for all casement window sizes. They have three position settings, indicated in the detail below. Do not install on windows intended for use as emergency exits. Device will hinder escape or rescue in an emergency. A3 A2 A1 C3 B3 B2 B1 C1 C2 Position A Position B Position C Unit Size A1 A2 A3 B1 B2 B3 C1 C2 C3 CR widths 1-7/16" 3-3/8" 4-7/8" 3-5/16" 5-5/16" 6-3/4" 13.56 22.07 28.27 CN widths 2-3/16" 4-11/16" 6-9/16" 4-1/8" 6-5/8" 8-3/8" 13.56 22.07 28.27 C widths 3" 6-1/8" 8-3/8" 4-15/16" 8" 10-1/8" 13.56 22.07 28.27 CW widths 4" 7-3/4" 10-7/16" 5-15/16" 9-9/16" 12-1/8" 13.56 22.07 28.27 CX widths 4-15/16" 9-1/8" 12-1/8" 6-7/8" 10-15/16" 13-3/4" 13.56 22.07 28.27 CXW widths 5-3/4" 10-5/8" 14-1/8" 7-3/4" 12-7/16" 15-11/16" 13.56 22.07 28.27 See complte instruction guide at www.andersenwindows.com Remove center screw on existing hinge track. Detach operator arm. Attach through hole 3, 2 or 1a. Reattach operator arm. Place vent limiter on hinge track. A R C H I T E C T U R A L D E T A I L F I L E 1-7
Casement and Awning Window Joining Details Narrow Joining Materials Non-Reinforced Joining 11/16" (18) 2-3/8" (60) casing non-reinforced wood joining material 1/8" (3) 2-3/8" (60) Option: casing for steel to cover operator underside 1/8" (3) Sealant and optional exterior trim strip Sealant and optional exterior trim strip casing non-reinforced wood joining material Aluminum Reinforced Joining 11/16" (18) 2-3/8" (60) casing 1/8" (3) aluminum reinforced join Sealant and optional exterior trim strip 1/8" (3) Sealant and optional exterior trim strip 2-3/8" (60) Option: casing for steel to cover operator underside casing aluminum reinforced join Steel Reinforced Joining 2-3/8" (60) 1-15/32" (37) casing for steel steel reinforced join 1/8" (3) 2-3/8" (60) casing for steel 1/8" (3) Sealant and optional exterior trim strip Sealant and optional exterior trim strip steel reinforced join 1-8 A R C H I T E C T U R A L D E T A I L F I L E
Casement and Awning Window Joining Details 2" Support Mullion Casing by others extension jambs Joining Compatibilty Many units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Product Guide, in Andersen Window Studio software, and by visiting andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified. Structure by others 2" (51) wood filler and vinyl trim NOTE: Reinforced component details are typical examples for large window combinations that require additional support for windload (lateral load) purposes. Determination of the reinforcing member(s) required for a specific job and appropriate selection of products which conform to all applicable laws, ordinances, building codes, and safety requirements is the sole responsibility of the architect, building owner and/or contractor. Check with your local building code officials for specific requirements and with your local Andersen supplier for general information. Andersen strongly recommends consultation with an architect or structural engineer to determine appropriate support and reinforcement. Andersen is not responsible for conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen unit, nor the fastening system used. A R C H I T E C T U R A L D E T A I L F I L E 1-9
Casement and Awning Window Anchoring Methods Flange Casement window is secured in the opening by using fasteners through the installation. Threaded Masonr y Fastener / Expansion Sleeve To secure a casement window unit in an opening, remove the sash stops and pre-drill through the side jambs for fastener installation. Exterior sheathing Metal fastener for securing (furnished by others) Clip Casement window unit secured in opening by others using 302 stainless steel sheet metal jamb clips and stainless steel screws. Bend the jamb clips to secure unit fit in opening. can be cut as required to accommodate the jamb clips. APPLICATION: Wood buck First secure jamb clip to back side of window unit jamb(s) Apply 12 apart on center starting 6 from corners of head jamb, sill and side jambs clip flat clip lateral design load capacity: maximum 200 lb. Score markings for bending clip 1-1/2" (38) 3/16" (5) auxiliary casing 3" (76) Unit will not operate properly if frame parts are stressed. Make sure that the unit frame parts do not become bowed when using anchoring methods. 1-10 A R C H I T E C T U R A L D E T A I L F I L E
Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) Casement and Awning Window all around Remove installation at head drywall return piece 1/2" (13)* minimum all around Wood Siding / 2 x 4 Wood Stud Framing *1/2" (13) minimum to accommodate differential shrinkage/expansion when brick is used with wood framing. Brick Veneer / 2 x 6" Metal Stud Framing Importance of Proper Proper installation and maintenance of products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows. com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. all around Membrane flashing over installation (by others) E.I.F.S. / Concrete Masonr y Unit (CMU) NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of the window. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. may be removed where construction sequence/ detailing requires no. A R C H I T E C T U R A L D E T A I L F I L E 1-11
Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) Casement and Awning Window auxiliary casing auxiliary casing vinyl trim board Existing frame wall at head and jambs all around Brick / Concrete Masonry Unit (CMU) Remove installation at sill Stucco / Concrete Masonry Unit (CMU) Inset Window all around Existing Stud Wall Andersen extension jambs vinyl trim board. Trim to fit as required. Finish trimmed edge with rigid vinyl channel Existing masonry wall Importance of Proper Proper installation and maintenance of products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows. com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of the window. all around Andersen extension jambs trimmed to fit NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. may be removed where construction sequence/ detailing requires no. 1-12 Existing Masonr y Wall A R C H I T E C T U R A L D E T A I L F I L E
Basic Unit Details - Single Sash Unit Basic Unit A w n i n g W i n d o w s 1-5/16" (33) 2-7/8" (73) extension jamb 2-3/16" (56) 1-1/8" (29) 15/16" (17) Glass Height High-Performance insulating glass Clear Opening Height 2-3/16" (56) 1-3/16" (30) 1-1/8" (29) Stationar y 1-1/8" 1-3/16" (29) (30) insect screen extension jamb 4-1/2" (114) 2-7/8" (72) High-Performance insulating glass 1-5/16" (33) 2-3/8" (60) Glass 2-3/8" (60) Unit Dimension Rough Opening A R C H I T E C T U R A L D E T A I L F I L E 1-13
Basic Unit Details - Picture Unit (P) Basic Unit A w n i n g W i n d o w s 1-5/16" (33) 2-7/8" (72) 1-1/8" (29) 1-3/16" (30) extension jamb extension jamb Rough Opening Unit Dimension 2-3/8" (60) Glass Height 2-3/8" (60) 1-1/8" (29) 1-3/16" (30) 1-3/16" (30) 1-1/8" (29) 2-7/8" (72) 1-5/16" (33) 2-3/8" (60) Glass 2-3/8" (60) Unit Dimension High-Performance insulating glass Rough Opening Options / Accessories Extension s 1/8" (3) Face: 4-9/32" (109) 7-1/8" Wall Face: 3-23/32" (95) 6-9/16" Wall Face: 2-13/32" (61) 11/16" (17) 5- Wall 4-9/16" Wall Face: 1-23/32" (44) 4-9/16" (116) 5- (133) 6-9/16" (167) 7-1/8" (181) Extension jambs available for 4-9/16" (116), 5- (133), 6-9/16" (167) or 7-1/8"(181) wall thickness. Other wall dimensions can be accommodated with extension jamb modification. 6-9/16" (167) extension jambs are predrilled for easy application. Rough Opening 1-14 A R C H I T E C T U R A L D E T A I L F I L E
A w n i n g W i n d o w s Options / Accessories Divided Light Grilles Available now Available only with 3/8" glass through the Andersen Divided Light program Please check with Andersen for availability Casement & Awning Casement Picture Window Gliding Window Woodwright Double-Hung & Transom Woodwright Picture Window Woodwright Archtop & Unequal Leg Archtop Andersen 400 Series Windows Woodwright Springline Single-Hung Tilt-Wash Double-Hung & Transom Tilt-Wash Picture Window Circle Top & Quarter Round Arch Springline Flexiframe Elliptical Circle & Oval Gothic 200 Series Narroline Double-Hung & Transom Andersen 400 Series Doors Frenchwood Gliding Frenchwood Hinged Inswing Frenchwood Hinged Outswing Frenchwood Patio Door Sidelights & Transoms Glass Patterns Interior Type Exterior Color White Sandtone Terratone Forest Green 3/4" 7/8" 1-1/8" 2- With Spacer Without Spacer Maple Oak Prefinished Pine Colonial Modified Colonial Modified Col W/Check Rail Prairie A Short Fractional Short Fractional W/Check Rail Tall Fractional Tall Fractional W/Check Rail Victorian Renaissance Sunburst Specified Equal Light Custom HP/HP Tempered HP Sun/HP Sun Temp 3/8" Low-E/Temp Single-Pane Impact A R C H I T E C T U R A L D E T A I L F I L E 1-15
A w n i n g W i n d o w s Options / Accessories 400 Series Grille Options Andersen Divided Light Grille Permanent Exterior Permanent Interior with Spacer Andersen Divided Light Grille Permanent Exterior Permanent Interior Andersen Divided Light Grille Permanent Exterior Removable Interior Removable Interior Andersen Finelight Grilles-Between-the-Glass Grille Profiles Scale = Full Dimensions include thickness of tape. Permanent Exterior Fibrex Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright double-hung windows. 5/16" 7/16" 1/2" 1-13/16" 45 45 35 45 5/16" 5/16" 5/16" 5/16" 3/4" 7/8" 1-1/8" 2- Permanent Interior Wood Grille Profiles (chamfer profile). The Fibrex material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright double-hung windows. 1/2" 1-13/16" 5/16" 7/16" 3/8" 53 3/8" 53 3/8" 35 7/16" 53 3/32" 7/8" 3/4" 1-1/8" 2- Removable Interior Wood Grille Profile (roman ogee profile). Removable Interior Wood Grille Profile (Chamfer profile). 400 Series Woodwright double-hung windows only. 1/2" 7/16" 3/4" 7/8" 1-1/8" 3/4" 7/8" 1-1/8" Permanent Full Divided Light Grille spacer location. 1/2" 1/2" 1/2" 1/2" 1/2" 1/8" 3/16" 5/16" 1/8" Andersen Finelight Grilles-Between-the-Glass. 3/8" 3/4" 1/2" 1" 1-16 A R C H I T E C T U R A L D E T A I L F I L E
Options / Accessories Extension Arm Pack A w n i n g W i n d o w s For venting awning windows A3 and wider. Adds approximately 3-3/4" to opening depth. See the installtion guide at www.andersenwindows.com for installation details. Attach extension arm to operator arm. Operator arm Remove standard operator rod. Remove standard operator shoe from operator arm. Standard Operator Long operator rod Extension arm Attach long operator rod. Extension arm Operator arm Operator with Extension Arm A R C H I T E C T U R A L D E T A I L F I L E 1-17
Options / Accessories Awning Vent Limiter - 2001 to present Scale: None Split arm vent limiters are available for awning window sizes excluding A335, A3535, AP32V, AP352V and AP42V units. They have two position settings, indicated in the detail below. A w n i n g W i n d o w s Do not install on windows intended for use as emergency exits. Device will hinder escape or rescue in an emergency. C1 Position A Position B Position C Unit Size A1 A2 B1 B2 C1 C2 AR heights 1-7/16" 3-3/8" 3-5/16" 5-5/16" 13.56 22.07 AN heights 2-3/16" 4-11/16" 4-1/8" 6-5/8" 13.56 22.07 A heights 3" 4-15/16" 13.56 AW heights 4" 5-15/16" 13.56 AX heights 4-15/16" 6-7/8" 13.56 AXW heights 5-3/4" 7-3/4" 13.56 See complte instruction guide at www.andersenwindows.com B2 B1 C2 A2 A1 Place vent limiter on hinge track. Remove center screw on existing hinge track. Attach through hole 2 or 1. Hole 3 not used. 1-18 A R C H I T E C T U R A L D E T A I L F I L E
Options / Accessories Vent Control Adaptor - 1978 to 2001 A w n i n g W i n d o w s For installation on both jambs. (Use to reduce opening depth adjustable.) 1. Remove the stopper screw that is located at the end of the hinge channel. 2. Install the vent control adaptor into the channel. Align the slot in the adaptor to the stopper screw hole. 3. Apply the stopper screw. 4. Close the window to the desired maximum opening, slide the vent control adaptor up as far as possible, and tighten the stopper screw. DO NOT use limited vent hardware on windows intended for use as emergency exits. Emergency escape or rescue may be hindered. Vent Limiter Stopper screw A R C H I T E C T U R A L D E T A I L F I L E 1-19
A w n i n g W i n d o w s Options / Accessories Operators Electric Window Opener For out-of-reach installations, the electric opener provides convenient power operation. Electric operator sill stop Electric operator Electric operator mounting bracket and operator Hex socket adaptor with flexible extension pole tip. Hex Socket Adaptor For out-of-reach installations when using an extension pole. It replaces the operator handle. Each vent operator extension pole (shown above) includes one hex socket adaptor. Operator Offset Extension Pole For out-of-reach installations, this extension pole easily controls the vent operator and shade. Pole adjusts from 6' to 10' in length. Each vent operator extension pole includes one hex socket adaptor. Operator projection 6-1/8" (156) from nailing Flexible Extension Pole Tip The flexible extension pole tip is used on the venting extension pole for steep pitched installations. Awning Window Typical Electric Opener System See the installtion guide at www.andersenwindows.com for installation details. Command Center (permanent wall mount installation) Power Supply Accessories Up to four window sash can be operated from one command center. 10 or 20 ft. extension cords are available for use with either the command center or the power operator (power operator and command center come with 10' cord). 1 2 3 4 Command Center (semi-portable, hand held installation) 1 2 3 4 Power Operator Rain Sensor Operation of Multiple Units For power operation with multiple units, purchase 1 electric window opener set for first window and 1 power operator set for each additional sash. Power operators can be added for up to three additional sash for each window opener set. Parts for the electric window opener for include: Single-Unit Electric Window Opener Set 1 power supply (converts 110 AC to DC) 1 command center with 10' cord (controls 4 operators maximum) 1 power operator (DC motor) with bracket and 10' cord 1 rain sensor 1 insect screen safety connector 1 roof window mounting bracket 1 Perma-Shield awning mounting bracket All mounting screws and instructions Power Operator Set 1 power operator with mounting bracket and 10' cord 1 rain sensor 1 insect screen safety connector 1 roof window mounting bracket 1 Perma-Shield awning mounting bracket All mounting screws and instructions 1-20 A R C H I T E C T U R A L D E T A I L F I L E
A w n i n g W i n d o w s Joining Details Narrow Joining Materials Non-Reinforced Joining 11/16" (18) 2-3/8" (60) casing non-reinforced wood joining material 1/8" (3) 2-3/8" (60) Option: casing for steel to cover operator underside casing 1/8" (3) Sealant and exterior trim strip Sealant and exterior trim strip non-reinforced wood joining material Aluminum Reinforced Joining 11/16" (18) 2-3/8" (60) casing aluminum reinforced join 1/8" (3) 2-3/8" (60) Option: casing for steel to cover operator underside 1/8" (3) Sealant and exterior trim strip Sealant and exterior trim strip casing aluminum reinforced join Steel Reinforced Joining 2-3/8" (60) 1-15/32" (37) casing for steel steel reinforced join 1/8" (3) 2-3/8" (60) 1/8" (3) Sealant and exterior trim strip Sealant and exterior trim strip casing for steel steel reinforced join A R C H I T E C T U R A L D E T A I L F I L E 1-21
Joining Details Support Mullion A w n i n g W i n d o w s Structure by others Casing by others extension jambs Joining Compatibilty Many units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Product Guide, in Andersen Window Studio software, and by visiting andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified. 2" (51) wood filler and vinyl trim NOTE: Reinforced component details are typical examples for large window combinations that require additional support for windload (lateral load) purposes. Determination of the reinforcing member(s) required for a specific job and appropriate selection of products which conform to all applicable laws, ordinances, building codes, and safety requirements is the sole responsibility of the architect, building owner and/or contractor. Check with your local building code officials for specific requirements and with your local Andersen supplier for general information. Andersen strongly recommends consultation with an architect or structural engineer to determine appropriate support and reinforcement. Andersen is not responsible for conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen unit, nor the fastening system used. 1-22 A R C H I T E C T U R A L D E T A I L F I L E
Anchoring Methods Flange A w n i n g W i n d o w s Awning window is secured in the opening by using fasteners through the installation. Threaded Masonr y Fastener / Expansion Sleeve To secure a casement window unit in an opening, remove the sash stops and pre-drill through the side jambs for fastener installation. Exterior sheathing Metal fastener for securing (furnished by others) Clip Awning window unit secured in opening by others using 302 stainless steel sheet metal jamb clips and stainless steel screws. Bend the jamb clips to secure unit fit in opening. can be cut as required to accommodate the jamb clips. APPLICATION: Wood buck First secure jamb clip to back side of window unit jamb(s) Apply 12 apart on center starting 6 from corners of head jamb, sill and side jambs clip lateral design load capacity: maximum 200 lb. clip flat Score markings for bending clip Score markings for bending (see insert above) 3/16" (5) auxiliary casing 1-1/2" (38) 3/16" (5) 1-1/2" (38) 3" (76) 3" (76) Make sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed. A R C H I T E C T U R A L D E T A I L F I L E 1-23
Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) all around A w n i n g W i n d o w s Remove installation at head drywall return piece 1/2" (13)* minimum all around Wood Siding / 2 x 4 Wood Stud Framing *1/2" (13) minimum to accommodate differential shrinkage/expansion when brick is used with wood framing. Brick Veneer / 2 x 6" Metal Stud Framing Importance of Proper Proper installation and maintenance of products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. all around Membrane flashing over installation (by others) E.I.F.S. / Concrete Masonr y Unit (CMU) NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of the window. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. may be removed where construction sequence/ detailing requires no. 1-24 A R C H I T E C T U R A L D E T A I L F I L E
A w n i n g W i n d o w s Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) auxiliary casing auxiliary casing vinyl trim board Existing frame wall at head and jambs all around Brick / Concrete Masonry Unit (CMU) Remove installation at sill Stucco / Concrete Masonry Unit (CMU) Inset Window all around Existing Stud Wall Andersen extension jambs vinyl trim board. Trim to fit as required. Finish trimmed edge with rigid vinyl channel Existing masonry wall Importance of Proper Proper installation and maintenance of products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S. wall finish is adjacent to window units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of the window. all around Andersen extension jambs trimmed to fit NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. may be removed where construction sequence/ detailing requires no. Existing Masonr y Wall A R C H I T E C T U R A L D E T A I L F I L E 1-25