PHY Feasibility Study for One or Two pairs RTPGE



Similar documents
A Feasibility Study of One Twisted Pair Gigabit Ethernet

Feasibility Study on High Speed Transmission over UTP Cables

10GBASE-T Objectives

A Simple Model of Relative Power vs. Reach

From OPEN Alliance BroadR-Reach PHYs to IEEE 802.3bp RTPGE

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

Data Communications Competence Center

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks

HSSG copper objectives and five criteria

How To Get A Better Signal From A Fiber To A Coax Cable

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

Enhanced Category 5 Cabling System Engineering for Performance

Introduction to Digital Subscriber s Line (DSL)

10GBASE-T: 10Gbit/s Ethernet over copper

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian

Total Solutions Verification

GigaSPEED X10D Solution How

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Abstract: This document examines the alien NEXT performance of various bundled cables and measures the impact upon various networks performance.

How Enhanced DSL Technologies Optimize the Last Copper Mile By John Williams

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

is the power reference: Specifically, power in db is represented by the following equation, where P0 P db = 10 log 10

V-DSL technology in the NBN

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

Backplane Ethernet Study Group Market Drivers and Cost Considerations in Support of 40 inch average grade FR4 backplane links at 10Gb/s per lane

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

Gigabit Ethernet on Copper Cabling Infrastructures

Broadband Video over Twisted Pair Cabling. By Paul Kish Director, IBDN Systems & Standards NORDX/CDT

Proposal: Option for in-band POTS and ISDN. Mikael Isaksson, Tomas Stefansson, Per Ödling, Frank Sjöberg, Kate Wilson

GSM frequency planning

Broadband access. Nils Holte, NTNU. NTNU Department of Telecommunications Kursdagene ved NTNU, Digitale telenett, 9. januar

Deployed 100Mb/s One Pair OABR PHY

Fibre Channel Fiber-to-Fiber Media Converters

Multi-Carrier GSM with State of the Art ADC technology

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Plastic Optical Fiber for In-Home communication systems

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

Broadcast digital subscriber lines using discrete multitone for broadband access

Application Note: How to Connect a Wired Ethernet Port to the WiPort

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

CONTRIBUTION ABSTRACT

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Network Requirements for DSL systems, (ADSL through G.Fast) (A summarized view)

with Component Rating A Simple Perspective

ethernet alliance 10GBASE-T: 10 Gigabit Ethernet over Twisted-pair Copper Version 1.0 August 2007

Evaluation Criteria for ADSL AFE1302

TCOM 370 NOTES 99-4 BANDWIDTH, FREQUENCY RESPONSE, AND CAPACITY OF COMMUNICATION LINKS

1000BASE-T: Gigabit Ethernet. over Category. 5 copper. cabling. Acronyms and abbreviations

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS

SR450 RECEIVER OPERATING INSTRUCTIONS

SFP Copper Transceiver 10/100/1000Base-T

SYSTIMAX Copper Solutions Designed for the Digital Generation

Non-Data Aided Carrier Offset Compensation for SDR Implementation

Achievable Transmission Rates and Self-Interference Channel Estimation in Hybrid Full-Duplex/Half-Duplex MIMO Relaying

RADIO FREQUENCY INTERFERENCE AND CAPACITY REDUCTION IN DSL

Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port

QAM Demodulation. Performance Conclusion. o o o o o. (Nyquist shaping, Clock & Carrier Recovery, AGC, Adaptive Equaliser) o o. Wireless Communications

HARTING mcon 1000 Introduction and features

EE290C - Spring 2004 Advanced Topics in Circuit Design High-Speed Electrical Interfaces

IT Cabling Solutions

Transmission of High-Speed Serial Signals Over Common Cable Media

Challenges of one pair automotive Ethernet from the wiring harness point of view

Zero-Variable Wireless Infrastructure Deployment. Datasheet. Models: BM2HP, BM5HP. Completely integrated Radio

Optical Communications Analysis of transmission systems. Henrique Salgado Point-to-point system

1.6 Gbit/s Synchronous Optical QPSK Transmission with Standard DFB Lasers in Realtime

AV1200 TL-PA8030P KIT. 3-Port Gigabit Passthrough Powerline Starter Kit. Highlights

Will Your Fiber Optic Cable Plant Support Gigabit Ethernet?

Dispersion penalty test 1550 Serial

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

Quectel M72 Development Board

STRUCTURED CABLING SYSTEMS

The Conversion Technology Experts. Media Conversion: Cost-Effectively Integrating T1 into your Fiber Network

HARTING econ 3000 Introduction and features

Serial Communications

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

Next Generation of High Speed. Modems8

Category 8 Cabling Standards Update

Implementation of Digital Signal Processing: Some Background on GFSK Modulation

Fast Ethernet and Gigabit Ethernet. Networks: Fast Ethernet 1

10/100/1000BASE-T SFP Transceiver

GHz SDH Digital Radio

Evolution from Voiceband to Broadband Internet Access

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

CW46S GPS Sensor P R O D U C T B R I E F. Description. Features. Applications. Block Diagram

Public Switched Telephone System

How To Define Hfc Technology

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Golden test for dispersion penalty 1550 Serial

Wireless Communication and RF System Design Using MATLAB and Simulink Giorgia Zucchelli Technical Marketing RF & Mixed-Signal

Gigabit Ethernet over Category 5 unshielded twisted pair cable. Evaluating electrical characteristics of 1000BASE-T Physical Layer Devices

Design Guidelines for PoE Based Security Systems. Carlos Carle, P.E. SignaMax Systems, Inc.

Transcription:

PHY Feasibility Study for One or Two pairs RTPGE July 2012 IEEE Reduced Twisted Pair Gigabit Ethernet Benson Huang, Joseph Chou Realtek Semiconductor Corp.

Supporters Mehmet Tazebay, Broadcom George Zimmerman, CME Consulting/Commscope Richard Mei, Commscope Mario Traeber, Lantiq Stefano Valle, ST Microelectronics 2

The Purpose This presentation attempts to evaluate the technical feasibility for RTPGE using the measured cable model. The cable model is obtained from Commscope in the contribution of mei_01_0712.pdf. It includes one-pair and two-pair cables with 3 or 5 connectors in different cable lengths. The model is extracted with 4-port S- Parameters. Use the Salz SNR (refer to huang_01_0512.pdf) for performance evaluation This is a case study and does not provide any baseline proposal of the standard nor the limit line of the worst case channel. 3

Outline Performance Analysis method & Cable Model FEXT and NEXT in Two Twisted Pair Cable Effect of Baud Rate Performance Comparison Complexity Discussion Conclusion 4

Performance Analysis Method & Cable Model Use Salz SNR for analysis as explained in Huang_01_0512.pdf Simulation parameters Transmission power = 3dBm 140dBm/Hz AWGN ADC/DAC of 8 bits ENOB PGA gain setting with the condition of ADC clipping rate = 10-5 TX 1st order filter cut off freq = baud rate & RX 3rd order filter cut off freq = 0.4*baud rate Transformer pole at 1MHz Perfect ECHO cancellation. Optional NEXT and FEXT cancellers as explained in the next page. Cable models Cable A Cable B Cable C Cable D Cable E Cable F Cable E Cable F Cable length 8m 8m 12m 12m 40m 40m 40m 40m # of Twisted-pair 1 2 1 2 1 2 1 2 # of Connector 3 3 5 5 5 5 5 5 Alien NEXT/FEXT YES YES NO NO YES YES NO NO NEXT/FEXT NO YES NO YES NO YES NO YES 5

FEXT and NEXT in Two Twisted Pair Cable 2 pair cable incurs NEXT and FEXT interference. The SNR difference of 40 meter cable with FEXT and w/o FEXT canceller is only 0.7dB. PAM-4 baud rate = 250MHz Cable B Cable F Cable length 8m 40m SNR w/i FEXT canceller 53.0dB 40.3dB SNR w/o FEXT canceller 48.0dB 39.6dB SNR difference 5.0dB 0.7dB Practically, SNR can be improved by less than 0.7 db due to the implementation loss of FEXT canceller. Therefore, the FEXT canceller is not considered in this evaluation. On the other hand, the Alien Crosstalks dominate the overall noise. The NEXT canceller contributes less than 0.1dB in all cases. The NEXT canceller is also not considered here. 6

Effect of Baud Rates It is assumed that the signal in each twisted pair is conveyed bi-directionally Pair 1 Pair 2 The higher baud rate gives the higher SNR margin. 1 pair SNR margin Cable A Cable E Cable length 8m 40m Baud rate 1000MHz 500MHz 333.3MHz 250MHz 1000MHz 500MHz 333.3MHz 250MHz Un-coded Modulation PAM-2 PAM-4 PAM-8 PAM-16 PAM-2 PAM-4 PAM-8 PAM-16 SNR margin * 18.6dB 17.6dB 14.7dB 11.1dB 9.4dB 8.5dB 5.7dB 2.2dB 2 pair SNR margin (w/o FEXT/NEXT cancellation) Cable B Cable F Length 8m 40m Baud rate 500MHz 250MHz 166.6MHz 125MHz 500MHz 250MHz 166.6MHz 125MHz Un-coded Modulation PAM-2 PAM-4 PAM-8 PAM-16 PAM-2 PAM-4 PAM-8 PAM-16 SNR margin* 25.8dB 24.0dB 20.9dB 17.2dB 16.9dB 15.7dB 12.7dB 8.9dB * SNR margin (w/o channel coding) = Salz SNR - Uncoded SNR at BER = 10-12 For ease of comparison, the same modulation coding scheme PAM-4 is picked, which yields different baud rates for I pair and 2 pair cables. 7

PAM-4 Performance Comparison Cable A Cable B Cable C Cable D Cable E Cable F Cable E Cable F Cable length 8m 8m 12m 12m 40m 40m 40m 40m # of Twisted-pair 1 2 1 2 1 2 1 2 # of Connector 3 3 5 5 5 5 5 5 Alien EXT/FEXT YES YES NO NO YES YES NO NO Baud rate 500MHz 250MHz 500MHz 250MHz 500MHz 250MHz 500MHz 250MHz Salz SNR 41.5dB 47.9dB 55.6dB 44.3dB 32.4dB 39.6dB 50.4dB 47.4dB SNR margin 17.6dB 24.0dB 31.7dB 20.4dB 8.5dB 15.7dB 26.5dB 23.5dB -6.4dB Common assumptions. -7.2dB -18.0dB -7.8dB w/o NEXT/FEXT cancellation PAM-4 modulation code (SNR = 23.9dB at BER = 10-12 ); no channel coding 2 pair has better SNR margin than 1 pair by 6.4dB at 8 meter cable assembly and 7.2dB at 40 meter cable assembly. The 1 pair solution requires further study on channel coding to enhance the SNR margin which is severely affected by Alien noise. 8

Complexity Discussion Since the uncoded PAM-4 is used in both Gigabit Ethernet (802.3ab) and here 1 pair and 2 pair RTPGE, the SNR requirement is identical. The implementation complexity can be therefore easy to compare. Minimum SNR = 23.9dB for AFE design target. Assuming that the 1 pair and 2 pair RTPGE use the same scheme of PCS/EEE/channel encoding/decoding as in 802.3ab. The complexity of equalization and interference cancellation can be reduced due to the shortening of cable length from 100 meter to 40 meter. An exemplary system spec. (All signals are bi-directional.) 802.3ab (4 pairs) 2 pair RTPGE 1 pair RTPGE ADC(Rx) ENOB 8 bit 8 bit 8 bit DAC(Tx) ENOB 8 bit 8 bit 8 bit System CLK 125MHz 250MHz 500MHz max cable length 100m 40m 40m 9

Complexity Discussion (cont) The AFE complexity : 802.3ab > 2 pair RTPGE > 1 pair RTPGE TSMC 40nm die size estimate (implementation dependent) 4 pair 802.3ab (125MB) 2 pair RTPGE (250MB) 1 pair RTPGE (500MB) Quantity Complexity Quantity Complexity Quantity Complexity ADC 4 1*A 2 1.4*A 1 3.0*A DAC 4 1*B 2 1.5*B 1 2*B PLL/PGA/LPF/Hybrid 4 1*C 2 1.2*C 1 1.4*C AFE Sub Total 4*A + 4*B + 4*C 2.8*A + 3*B + 2.4*C 3.0*A + 2*B + 1.4*C The Computational complexity : 1 pair RTPGE >= 802.3ab > 2 pair RTPGE 802.3ab (4 pairs) 2 pair RTPGE 1 pair RTPGE Quantity Complexity Quantity Complexity Quantity Complexity FFE 4 8 taps*1 2 6 taps*2 1 13 taps*4 FBE 4 16 taps*1 2 13 taps*2 1 26 taps*4 NEXT 4 25 taps*1*3 2 0 1 0 ECHO 4 125 taps*1 2 100 taps*2 1 200 taps*4 PCS/channel decoding/interface 4 1*D 2 1*D 1 1*D Digital Sub Total 896 taps +D 476 taps + D 956 taps + D Overall Complexity: 802.3ab > 2 pair 1 pair 10

Conclusion Both 1 and 2 pair cables demonstrate the technical feasibility of RTPGE 2 pair exhibits better SNR margin than 1 pair RTPGE. If considering the cable cost or weight, the 1 pair RTPGE has advantage when its overall implementation complexity is close to that of 2 pair RTPGE The 1 pair 40 meter cable deserves the further study of the performance impact caused by the environment 11

Thank you Questions?

Backup

Minimum SNR Required minimum SNR in db at BER = 10^-12 PAM-2 SNR = 17.0 PAM-4 SNR = 23.9 PAM-8 SNR = 30.1 PAM-16 SNR = 36.0

Computational complexity example Double the baud rate, the computational complexity becomes 4 times Double the baud rate, the ADC output date becomes double Double the baud rate, the processing speed (CLK) becomes double Echo response CLK = 125MHz CLK = 250MHz Take Echo Canceller as an example Assuming that 100meter at 125MHz baud rate needs 125 taps 40meter at 125MHz baud rate needs 125*40/100 = 50 taps 40meter at 250MHz baud rate needs 50*2 = 100 taps. Double the CLK rate, total computational complexity becomes 100 taps*2 40meter at 500MHz baud rate needs 100*2 = 200 taps. Quadruple the CLK rate, total computational complexity becomes 200 taps*4

The PSAACRF of 40m cable Cable only PSAELFEXT Cable and 5 connectors PSAELFEXT 16

SNR vs. Baud Rate Cable only Alien Crosstalks Cable and 5 connectors Alien Crosstalks 17