Blown Fibre Tube Cable Connectivity



Similar documents
Installation Procedure For 40mm Swept T Enclosure (Blown Fibre Cables)

Wall Mounted Products

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Mini USB and USB 2.0-IP67 Connector System

FIRE RESISTANT CABLES FP200 GOLD

2178-S Fiber Optic Splice Case

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 BASEC APPROVED PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

400 Series Buccaneer BUCCANEER POWER. bulgin

Assisted lift operated 2/2-way solenoid valves Type EV250B

Installation Detailed installation instructions are provided which should be strictly followed.

Hose and Tube Fittings Series 1-3

Terminal Boxes Series 8146

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

SciTech, sro Praha Ceník Jour Research tisk

SIMPLAIR PIPING TOOL

4 Small Cables Sealing Kit: Wrap Style

Guide rail bracket (for adjustable heads)

MVX-Series Diesel Engine Air Shut Down Valves

CutMaster Major External Replacement Parts

SOURIAU s discrete wire sealing

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Assembly instructions VOSS quick connect system 246 NX

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

A New Improved Range of Push-fit Fittings for Cold Water Services

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Operating Instructions

SELECTION, APPLICATION AND MAINTENANCE

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

3/2-way Solenoid Valve, direct-acting, NC or NO

Complete Systems & Parts Automatic Oiler & Grease Bank

SELECTION, APPLICATION & MAINTENANCE

The Axial Flow Valve. Class 300/ SERIES

Saferand easierinstallation

VW Caddy W INSTALLATION INSTRUCTIONS

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

RTD Temperature Probe for the Food/Pharmaceutical Industry

TN2000 Series Pneumatic Piston Actuators for DN125 to DN300 SPIRA-TROL Series Control Valves

GROENEVELD AUTOMATIC GREASING SYSTEMS

Metric Composite Push-In Fittings

COMMUNICATIONS ALLIANCE LTD NATIONAL BROADBAND NETWORK FIBRE READY DISTRIBUTION NETWORKS

Powers Controls TH 192 S Single Temperature Room Thermostat

ilan Ethernet Box for 9100 Installation Manual

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS

Post Mount Light Installation*

EZ-Steer Assisted Steering System

British Standard Underground Hydrant Range

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Cable Plug acc. to DIN EN , Form A

Uni-Quick Duct System. Moveable. Uni-Quick. Duct System. DUST COLLECTION and MATERIAL HANDLING APPLICATIONS a McGill AirFlow product

ACS.VESLP1.LIMITED SCOPE SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC.LPG GAS STORAGE VESSELS

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

Accessories. Fittings 2. Products assembly 4. Tube Spike 3/5 mm 8 T.N.L. 9. Vacuum Breaker 10. Line Flush Valve 11. Pressure Indicator 12

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

4RU High Density Shelf Installation Instructions

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics


Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

A&C Solutions: please contact us.

Norbro Series 40R Pneumatic Actuator Double Acting or Spring Return

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

Cajon VCR Fittings. Flanges, Fittings, & Components. Cajon & Swagelok Fittings. Cajon VCR Fittings. Nuts, Caps, & Plugs. Socket Weld Glands

Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) IP66. Improved catch.

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

WATER MAIN CONSTRUCTION TECHNIQUES DEPARTMENT OF PUBLIC WORKS WATER & WASTEWATER DIVISION

Floor Heating Warehouse.co.uk

System Accessories Pricing. Page 0 Effective 7/02

EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N

Guide to Safety Edge Systems

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX

VW T5 Airtronic D2 12V Heater Kit Part No.E6175 Installation Instructions

HP 16/18-Port Cable Management Kit Installation Guide

A&A CORVETTE PERFORMANCE C6 BOOST & FUEL GAUGE INSTALLATION INSTRUCTIONS

Repeaters and Mimics Data Sheet

MANTA Piston Distributor for Oil and Fluid Grease

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY

Single sub-base valve

CutMaster Major External Replacement Parts

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

Universal Vehicle Power Supply 9007AX01. Installation Instructions

Baumann Flexsleev Sanitary Control Valve

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

1 1.5" (38 mm) Diameter

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

HARTING Ethernet Cabling 4-poles Overview

SIR INTERMEDIATE LIFTING STATIONS Communal waste water 50 Hz OPERATING LIMITS APPLICATIONS. AdVANTAGES

OPERATING INSTRUCTION MANUAL FOR S-240 HYDRAULIC CUTTERS WITH PARTS LIST

Spare Parts Program. Parts, Consumables & Accessories superproductsllc.com

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Ocean Engineering Technical Data Sheet Stuffing Tubes

KA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting

MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types)

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

ELECTRICAL CONNECTORS

ACCESSORIES OXYGEN-THERAPY

THE PROFESSIONAL S ANSWER TO JUMP LEADS

Transcription:

Blown Fibre Tube Cable Connectivity Prysmian Part Numbers: See Individual Descriptions 1) Swept Tee Branching Unit 3) Extended In-Line Enclosure 2) 90 Tee Piece Branching Unit 4) 4 Port Extended In-line Enclosure 5) Tube Intercept Joints This is a guide to the selection of cable connectivity used in the Sirocco system. These items are used for blown fibre tube connectivity only and not for fibre connectivity. Items 1 4 are used to join or distribute from blown fibre tube cables with 7 tubes or more (when utilising any of the Direct Buried range of tube constructions) and for 12 tubes or more when utilising the Direct Install range (cable diameter dependent). Item 5 would be used to accommodate up to a 7 tube cable with up to 4 tube cable for the drop. These connectivity products can be introduced as part of the original network build, or can be fitted at a later date as required. The units are intended to protect the area of the tube-to-tube connection and allow access to the tubes to establish the initial link and any additional future links or revised routing i.e. they are re-enterable. Features and Benefits All products can be fitted on day one or retro-fitted as required. All products are suitable for direct burial or installation in manholes. Fast installation using Sirocco cable and tube cutters. Individual tubes can be connected or blocked using the standard range of Sirocco tube connectors (see datasheet SA001) Items 1 4 Resistant to significant ingress of mud, sand and debris. Impact resistance a 1kg steel ball falling from a height of 2m. Items 1 & 2 available as kits with grab rings, port reducers & manifolds. For items 3 & 4, these are supplied separately. Item 5 Sealing to IP041. Supplied with necessary cable adapters, end caps, connectors and cable ties for in-line cable plus one drop cable. Internal product moulded with LSOH material. Kit Contents These products are sometimes supplied as a kit comprising the body of the branching unit together with the appropriate inserts to manage the cables to be used in it. In most cases the kit would include the following additional parts: Grab Rings used to cushion the primary cable within the body of the branching unit (alternatives appropriate to size of cable being used). Port Reducer used to allow cushioning of smaller drop cable from primary cable link. Manifold and Plug Kits used to manage a number of drop cables from a primary cable link. See following pages for kit contents. Page 1 of 8

40mm Swept Tee Branching Unit Prysmian Part Numbers: See Table Below 325mm 250mm 80mm The Swept Tee Branching Unit is designed to intercept Sirocco tube cables, either during initial construction or at a later date and allow single tube cables to be branched off to customer premises. The units are designed to permit blown fibre units to be installed from one direction only. The customer drop cables can be either; 1-off 1 way Direct Buried or Direct Install cable (Using the Port Reducer XCCSC00016) 1-off 2 way Direct Buried or Direct Install cable (Also using Port Reducer XCCSC00016) Up to 3-off 1 way Direct Buried or Direct Install cables (Using the Manifold and Plug Kit XBFSC00104) Part Number Information Available as individual parts or as a kit. The table below lists the items that would be included in each kit. Kit Description Part No. Kit Contents Kit Contents Part No. Swept Tee Kit for use with primary cable, either XBFSC00105 1 x 40mm Swept Tee Body XCCSC00003 24 or 19 way Direct Buried Tube Cable 2 x 40mm Grab Rings As part of XCCSC00003 1 x 40/10-20mm Port Reducer XCCSC00016 Swept Tee Kit for use with primary cable, either XBFSC00106 1 x 40mm Swept Tee Body XCCSC00003 24 or 19 way Direct Install Tube Cable 2 x 40/32-28mm Grab Rings XCCSC00014 or 12 way Direct Buried Tube Cable 1 x 40/10-20mm Port Reducer XCCSC00016 Swept Tee Kit for use with primary cable, either XBFSC00112 1 x 40mm Swept Tee Body XCCSC00003 12 way Direct Install Tube Cable 2 x 40/22mm Grab Rings XBFSC00102 or 7 way Direct Buried Tube Cable 1 x 40/10-20mm Port Reducer XCCSC00016 Refer to CIG038 for assembly instructions Prysmian Telecom Cables & Systems UK Ltd, Chickenhall Lane, Bishopstoke, Hants SO50 6YU, UK Technical Enquiries +44 (0) 2380 608760 Fax Number +44 (0) 2380 608769 PRYSMIAN 2006. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian. Issue 01,July 2006 Ref: SA002-01 Page 2 of 8

40mm 90 Tee Piece Branching Unit Prysmian Part Numbers: See Table Below 350mm 250mm 100mm The 90 degree Tee Piece Branching Unit is designed to intercept Sirocco tube cables, either during initial construction or at a later date and allow single tube cables to be branched off to customer premises. The units are designed to permit blown fibre units to be installed from both directions. The customer drop cables can be either; 1-off 1 way Direct Buried or Direct Install cable (Using the Port Reducer XCCSC00016) 1-off 2 way Direct Buried or Direct Install cable (Also using Port Reducer XCCSC00016) Up to 3-off 1 way Direct Buried or Direct Install cables (Using the Manifold and Plug Kit XBFSC00104) Part Number Information Available as individual parts or as a kit. The table below lists the items that would be included in each kit. Kit Description Part No. Kit Contents Kit Contents Part No. 90 o Tee Kit for use with primary cable, either XBFSC00107 1 x 40mm 90 o Tee Piece Body XCCSC00002 24 or 19 way Direct Buried Tube Cable 2 x 40mm Grab Rings As part of XCCSC00002 1 x 40/10-20mm Port Reducer XCCSC00016 90 o Tee Kit for use with primary cable, either XBFSC00108 1 x 40mm 90 o Tee Piece Body XCCSC00002 24 or 19 way Direct Install Tube Cable 2 x 40/32-28mm Grab Rings XCCSC00014 or 12 way Direct Buried Tube Cable 1 x 40/10-20mm Port Reducer XCCSC00016 90 o Tee Kit for use with primary cable, either XBFSC00113 1 x 40mm 90 o Tee Piece Body XCCSC00002 12 way Direct Install Tube Cable 2 x 40/22mm Grab Rings XBFSC00102 or 7 way Direct Buried Tube Cable 1 x 40/10-20mm Port Reducer XCCSC00016 Refer to CIG041 for assembly instructions Page 3 of 8

50mm Extended In-line Enclosure Prysmian Part Number: XBFSC00094 640mm 100mm 100mm The Extended In-line Enclosure is designed for blown fibre tube cable connection applications and can also be used as a device to permit extended range blowing for the blown fibre units. It is possible to joint the following cables or combinations thereof; 12, 19, and 24 way Direct Install cables 7, 12, 19, and 24 way Direct Buried cables. Part Number Information The table below lists the items that are required for use with the 50mm Extended In-line Enclosure (XBFSC00094) to accommodate the various cables that could be used. Item Description Relevant Cable Type Part No. Extended In-Line Enclosure XBFSC00094 50-40mm Grab Ring 24-way Direct Buried Tube Cable XCCSC00030 50-32mm Grab Ring 24-way or 19-way Direct Install Tube Cable XCCSC00035 or 19-way or 12-way Direct Buried Tube Cable " 50-25mm Grab Ring 12-way Direct Install Tube Cable XCCSC00037 or 7-way Direct Buried Tube Cable " 40mm Side Port Adapter XBFSC00148 Port Reducer Grab Ring for 40/32-28mm 12-way Direct Buried Tube Cable XCCSC00014 Port Reducer Grab Ring for 40/22mm 12-way Direct Install Tube Cable XBFSC00102 or 7-way Direct Buried Tube Cable " Port Reducer Grab Ring for 40/20-10mm 7/4/2-way Direct Install Tube Cable XCCSC00016 or 4/2-way Direct Buried Tube Cable " 10mm Manifold and Plug Kit 5 x 1-way Direct Buried Tube Cable XBFSC00104 50mm Port Plug XCCSC00036 Please note, grab rings must be ordered for each port of the Extended In-Line Enclosure to suit requirement. Refer to CIG039 for assembly instructions Prysmian Telecom Cables & Systems UK Ltd, Chickenhall Lane, Bishopstoke, Hants SO50 6YU, UK Technical Enquiries +44 (0) 2380 608760 Fax Number +44 (0) 2380 608769 PRYSMIAN 2006. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian. Issue 01, July 2006 Ref: SA002-01 Page 4 of 8

50mm 4 Port Extended In-line Enclosure Prysmian Part Number: XCCSC00015 640mm 180mm 100mm The 4 Port Extended In-line Enclosure is designed for blown fibre tube cable connection and distribution applications, and can also be used as a device to permit extended range blowing for the blown fibre units. It is possible to joint the following cables or combinations thereof; 12, 19, and 24 way Direct Install cables. 7, 12, 19, and 24 way Direct Buried cables. Part Number Information The table below lists the items that are required in addition to the 50mm 4 Port Extended In-line Enclosure (XCCSC00015); these items are determined by the type of cables that are going to be used in each application. For any ports that are not used, a 50mm Port Plug (XCCSC00036) should be used. Item Description Relevant Cable Type Part No. 4-Port Extended In-Line Enclosure XCCSC00015 50-40mm Grab Ring 24-way Direct Buried Tube Cable XCCSC00030 50-32mm Grab Ring 24-way or 19-way Direct Install Tube Cable XCCSC00035 or 19-way or 12-way Direct Buried Tube Cable " 50-25mm Grab Ring 12-way Direct Install Tube Cable XCCSC00037 or 7-way Direct Buried Tube Cable " 50mm Port Plug XCCSC00036 Please note, grab rings must be ordered for each port of the Extended In-Line Enclosure to suit requirement. Refer to CIG042 for assembly instructions Page 5 of 8

Alternative Components for use with Branching Units For use with Items 1 & 2 40/32-28mm Grab Ring XCCSC00014 40/22mm Grab Ring XBFSC00102 40/10 20mm Port Reducer XCCSC00016 5 x 10mm Manifold & Plug Kit XBFSC00104 For use with Items 3 & 4 50 40mm Grab Ring XCCSC00030 50 32mm Grab Ring XCCSC00035 50 25mm Grab Ring XCCSC00037 50mm Port Plug XCCSC00036 Prysmian Telecom Cables & Systems UK Ltd, Chickenhall Lane, Bishopstoke, Hants SO50 6YU, UK Technical Enquiries +44 (0) 2380 608760 Fax Number +44 (0) 2380 608769 PRYSMIAN 2006. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian. Issue 01, July 2006 Ref: SA002-01 Page 6 of 8

Tube Intercept Joint Prysmian Part Numbers: XJTSC00203 (External) XJTSC00204 (Internal) 350mm 130mm 52mm The Tube Intercept Joints are in-line closures designed for intercepting a blown fibre tube cable to allow a spur-off to smaller blown fibre tube cable drops. The closures are non-watertight but meet the requirements of IP41. No screws or fixings are required to assemble the closures. The closures are supplied with sufficient components to install the in-line blown fibre tube cable and a blown fibre tube drop cable of up to 4 tubes. The units can be used both as a Cable Distribution Joint and in Cable Jointing Applications. The Internal and External Tube Intercept Joints are supplied with cable adapters, 4 x 5mm end caps, 4 x 5mm straight connectors and cable ties, sufficient to enable the preparation, installation and connection of one in-line blown fibre tube cable and one blown fibre tube drop cable. The Internal product is moulded with Low Smoke Zero Halogen (LSOH) material. In both designs, there is an internal metal chassis (stainless steel) for cable retention and simple installation. Page 7 of 8

Tube Connectors Prysmian Part Numbers: see Datasheet SA001 To actually make the individual tube connections or cap unused tubes, preventing moisture or solid material migration, inside all of these blown fibre tube connectivity products, a range of tube connectors are available which push fit over the 5mm tubing to achieve a water and gas-tight connection. The capabilities of the range of tube connectors can be found in datasheet SA001. Tools Prysmian Part Numbers: see Datasheet SA004 In order to prepare the blown fibre tube cables for distribution or connection, the blown fibre tube cables and the tubes will need to be prepared. The recommended tooling is identified in datasheet SA004 and will also be referred to in the relevant CIG (Cable Installation Guide) as noted throughout this datasheet. Prysmian Telecom Cables & Systems UK Ltd, Chickenhall Lane, Bishopstoke, Hants SO50 6YU, UK Technical Enquiries +44 (0) 2380 608760 Fax Number +44 (0) 2380 608769 PRYSMIAN 2006. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian. Issue 01, July 2006 Ref: SA002-01 Page 8 of 8