Product Catalog. Tracer SC System Controller For Tracer Building Automated Systems BAS-PRC031-EN. July 2010



Similar documents
Tracer Summit Web Server

Product Catalog BAS-PRC010-E4. Tracker Version 12 Building Automation System. August 2010

Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 1)

Workshop 7 PC Software - Tracker

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Tracer Summit. Critical Control System BAS-PRC017-EN. May 2004

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Tracer Summit. Building Automation System BAS-PRC001-EN. November 2009

Insight Advanced Workstation

Emerson Smart Firewall

Section TELEPHONE AUTOMATIC DIALER SYSTEM

It s all open from here.

HMI display Installation Guide

Daily Operations TRACER SUMMIT

UNIFIED FACILITIES GUIDE SPECIFICATIONS

How To Learn To Use A Trane Building Control System

Energy Communication Unit (ECU)

Building Management Systems

Temperature & Humidity SMS Alert Controller

BACnet. bcx1 Controller/ Router Series

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Energy Communication Unit (ECU)

FX07 Field Controller

Tracker. Tracker Version 12 Building Automation System BAS-PRC010-EN. March 2008

Electronic Control Devices The European Product Catalogue 2007

Metering for today s systems

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version


Passion for Innovation

INSTALLATION INSTRUCTIONS

FX07 Field Controller

OPENweb. Efficient controlling at the highest level.

Electronic Control Devices The European Product Catalogue 2007

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

CMS Central Monitoring System

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Model: DC-A2IO Advanced HVAC Controller

Product Catalog. Trane eview Energy Reporting Software BAS-PRC054-EN. November 2010

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Temperature Alert. LAN-based Temperature and Humidity Data Logger

Variable Air Volume - VAV

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Back-UPS Pro 1300/1500 Installation and Operation

Powerline 1200 User Manual

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

RRV934. Multi-controller. Synco living

Medical Vacuum Systems-PXMI

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8

Wireless Router Setup Manual

NETWORK ENABLED EQUIPMENT MONITOR

Personalise energy solutions

Quareo ICM Server Software

Licenses of savic-net for Integrated Building Management System, and for FDA Title 21 CFR Part 11 Compliance

Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business

OZW30. Central Unit SYNERGYR

Chapter-5 Introduction to Building Automation System (BAS)

EnerVista TM Viewpoint Monitoring v7.10

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

3466 Building Energy Management Training Systems

The Access Engine. Building Integration System - The Access Engine. Security Systems

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

User Manual. EtherUSB

Functional Specification Document

CM500 High Speed Cable Modem User Manual

A-307. Mobile Data Terminal. Android OS Platform Datasheet

savic-net for Integrated Building Management System

Application Note #563 Revision A November 2015 Lutron / Automated Logic BACnet Integration

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

SNMP Web Management. User s Manual For SNMP Web Card/Box

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

NMS300 Network Management System

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Datasheet. Unified Video Surveillance Management. Camera Models: UVC, UVC-Dome, UVC-Pro NVR Model: UVC-NVR. Scalable Day or Night Surveillance

GadgetGatewayIa Configurable LON to IP Router and/or Remote Packet Monitor. ANSI (LonTalk ) and ANSI 852 (IP) standards based.

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

SCADA Questions and Answers

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

IDDERO HOME SERVER. Quick start guide

Job Aid Pre-Installation Information S8500 Media Server

BabyWare Imperial PC Software

Cisco MCS 7816-I3 Unified Communications Manager Appliance

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

7 MEGAPIXEL 180 DEGREE IP VIDEO CAMERA

IntesisBox KNX LG Air Conditioning

CATALYST Frequently Asked Questions

ABB solar inverters. User s manual ABB Remote monitoring portal

HyperAccess Access Control System

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, power control, and power and energy-monitoring function

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

Scalar i500. The Intelligent Midrange Library Platform FEATURES AND BENEFITS

Installation and Operation Back-UPS 1250, 1300, 1500

Smart Thermostat page 1

Transcription:

Product Catalog Tracer SC System Controller For Tracer Building Automated Systems July 2010 BAS-PRC031-EN

Copyright 2010 Trane All rights reserved This document and the information in it are the property of Trane and may not be used or reproduced in whole or in part, without the written permission of Trane. Trane reserves the right to revise this publication at any time and to make changes to its content without obligation to notify any person of such revision or change. Trademarks Trane and its logo are trademarks of Trane in the United States and other countries. All trademarks referenced in this document are the trademarks of their respective owners. BAS-PRC031-EN, 19 Jul 2010 2

Table of Contents Product Introduction.................................................... 4 User Interface..................................................... 5 Alarms and Events............................................ 6 Data Logs.................................................... 6 Schedules.................................................... 7 Area........................................................ 8 Variable Air Systems........................................... 8 Chilled Plant Control........................................... 8 Overrides.................................................... 9 Reports...................................................... 9 Tracer Graphical Programming (TGP2)............................ 9 Graphics and the Tracer Graphics Editor.......................... 9 Tree Layout................................................. 12 Backup and Restore.......................................... 12 Troubleshooting............................................. 12 Security.................................................... 12 Hardware Components............................................ 13 Tracer Building Automation System..................................... 14 Tracer System Architecture........................................ 14 User Interface Control......................................... 15 System Control.............................................. 15 Unit Control................................................. 15 Service Tools..................................................... 16 Resources............................................................ 17 Specifications......................................................... 18 BAS-PRC031-EN, 28 Jul 2010 3

Product Introduction The Tracer SC system controller acts as the central coordinator for all individual equipment devices on a Tracer building automation system (see p. 14). The Web-based interface of the Tracer SC system controller provides an easy and convenient way for building operators to access their building automation system. Access is available from any personal computer that meets system requirements, even from remote locations. The following list highlights the features and benefits of the Tracer SC system controller: Features User interface: Web-enabled Simpler to navigate to status and setting screens View the most frequently needed facility status information from one page Automatic data collection on key unit and system parameters Enhanced data logging capabilities Easier to create complex graphics to better represent your HVAC system Open, scalable, flexible controls: Scalable system size to accommodate customers specific needs (small steps can be taken to building up system size) Protocol-independent communications (BACnet, LonTalk ) BACnet, LonTalk, or any combination on the same system Achieve points toward Leadership in Energy and Environmental Design (LEED) certification through: Site commissioning report Energy data collection measurement Optimizing energy performance Maintaining indoor air quality Energy-saving programs: Fan pressure optimization Controls pressure in ductwork based on demand Ventilation reset Conditions only the required amount of outdoor air Chiller Plant Control (CPC) Manages chiller adds and subtracts to meet cooling loads Pre-programmed system applications: Alarm and event log Variable Air Systems (VAS) Area Chiller Plant Control Scheduling Overrides Reporting Data logging Security Faster installation and commissioning: Device discovery Preformatted object types Preconfiguration of controller data Benefits Provides access to system data from any PC in any location. More users can access the HVAC system. Increased usability and improved performance. Accommodates future changes through flexible technology. Lower operating costs through less energy use. Minimize impact on environment and infrastructure. Increase worker productivity through better air quality and reduced absenteeism. Make buildings run more efficiently. Provide consistent comfort and improved indoor air quality. Reduce/eliminate hot/cold complaints. Gets your building up and running faster. 4 BAS-PRC031-EN, 28 Jul 2010

Product Introduction User Interface The Tracer SC user interface provides an easy way for building operators to set up, operate, and modify a building automation system. The home page (Figure 1) contains system status information and links to navigate to all areas of the system. The main features of the user interface are described in this section. Figure 1. Tracer SC user interface: Home page Tree layout tool for graphics Global navigation bar System navigation links Alarm quantity by event class Currently active schedules Current status 5 BAS-PRC031-EN, 28 Jul 2010

Product Introduction Alarms and Events Events are occurrences that are detected by a Tracer building automation system. They can include diagnostics, critical operating conditions, as well as routine procedures. An event that is triggered by the detection of an abnormal or critical operating condition is generally considering to be an alarm. If an alarm exists, an alarm icon flashes in the global navigation bar, which remains visible in the right corner of every page of the user interface (see Figure 2, for example). When the system detects an event, data about the event appears in a log on the Alarms and Events page (Figure 2). The data displayed in the log includes when and where the event occurred and whether the operator is required to acknowledge it. An operator can also use the log to add comments about events. Column headings can be used to sort and filter events. They can also be removed or exported from the log. Figure 2. Alarms and Events log Data Logs The Alarms and Events log has seven categories that can be used to sort and filter them. Sorting can be based, for example, on severity level. Filtering can be used to view only the alarms from a specific piece of equipment, for example, or those received at a specific time or from a specific alarm category. Events can also be routed by e-mail to selected system operators. Event routing rules can be configured so that events respond to specific conditions when they occur. Data logs, also referred to as trends, allow the user to produce a variety of data samples at defined intervals to show the historical and current status of the facility. Data logs record, in real-time, the value of a data point in the system and the time at which the value was recorded. BAS-PRC031-EN, 28 Jul 2010 6

Product Introduction Data logs can be viewed in real-time, or at a later time in either graphical or tabular format. They can also be printed and saved. With the proper security access, system users can configure (create, delete, and update) and manage (clear, enable, and disable) data logs in the system. (See Figure 3 for an example of a data log.) Figure 3. Data log example Schedules Scheduling is one of a facility s most important energy-saving strategies. Its use ensures that equipment runs only when needed. Schedules can be used to: Keep equipment running at minimal energy-use levels on weekends and holidays Create exceptions to the standard schedule Perform optimal start and stop of equipment to optimize energy use while maintaining comfort requirements Change setpoints at specific times of day 7 BAS-PRC031-EN, 28 Jul 2010

Product Introduction From the home page, you can select: All schedules, which shows all schedules in the system Active schedules, which shows just the active schedules in the system Figure 4 shows an example of an All Schedules page. Figure 4. The All Schedules page Area Variable Air Systems Chilled Plant Control The Area application coordinates HVAC equipment for a specific area of the building. You can use the application to assign unit controllers, binary outputs, and binary values to be members of a common area. You can then efficiently perform a single operation (such as changing a setpoint, creating a schedule, performing an override) and apply it to all members of the area. In addition, the area application can use one of six algorithms, along with area temperatures and humidity inputs, to make an economizing decision. The application also supports optimal start/stop, humidity pulldown, night purge, unoccupied heating/cooling, unoccupied humidify, unoccupied dehumidify, and timed override functions. The Variable Air Systems (VAS) application coordinates air-handling units, variable-air-volume (VAV) boxes, and ventilation within a building. VAV units are assigned to the air-handling unit that supplies air to them. The VAS application coordinates the start-up and shut-down of the system to ensure proper static pressure control. Energy-saving applications, including static pressure optimization and ventilation optimization, are available as standard VAS application features. The Chiller Plant Control application coordinates chillers and provides system chilled water control. It controls the leaving-water temperature by adding chillers as the building cooling load increases, calculates the chilled water setpoint for each chiller, and recovers from failures by starting the next chiller in the sequence immediately after a chiller is marked as failed. BAS-PRC031-EN, 28 Jul 2010 8

Product Introduction Overrides Reports CPC optimizes energy use by subtracting chillers when the requirements of the cooling load decreases. In addition, CPC matches chillers to the building load and equalizes runtime and wear on each chiller by using different rotation schemes. Overrides can be performed on equipment, areas, and points for either a designated amount of time or until the user decides to put the point back into automatic control. Standard reports for Trane equipment are available from Tracer SC. These reports provide a valuable source of data that can be used for record-keeping and troubleshooting. Report types include: Site reports VAS commissioning reports Points reports Chiller reports Report features include: Scheduling reports to run during specific date periods and run frequencies Specifying file storage options for scheduled reports Exporting reports to save to your PC as csv, text, or pdf files Editing scheduled reports Tracer Graphical Programming (TGP2) Tracer Graphical Programming (TGP2) is a powerful graphical program that allows you to customize Tracer system applications. TGP2 routines are typically used for sequencing equipment, calculating setpoints and values, and performing shutdown sequences. Note: TGP2 is available through the Tracer TU service tool. Graphics and the Tracer Graphics Editor The Tracer Graphics Editor, available through the Tracer TU service tool, is used to create, edit, and publish graphics for use on Tracer SC. Graphics on the Tracer SC are used to monitor and control building equipment and applications. They can display data related to climate, lighting, and other controllable operations. They can be used to change setpoints and to override equipment operation. The Tracer Graphics Editor can be used to align graphical elements, determine which elements appear on top, and perform cut, copy, and paste functions. You can include in graphics: Any data that is available in the system as a numerical or text value Analog values that can change colors if they deviate from a desired value Multiple graphic images in JPEG, GIF, and animated GIF formats Visual elements from the building, such as floor plans or exterior views from CAD drawings Digital photography in JPG and GIF formats Animated images to represent binary and analog values Target buttons that provide links to related sources User controls including push buttons, check boxes, drop-down list boxes, and entry fields Graphics can be grouped in a logical way to make navigation through the building automation system simulate walking through the building. See Figure 5, Figure 6, and Figure 7 as examples. 9 BAS-PRC031-EN, 28 Jul 2010

Product Introduction Figure 5. Home page showing graphic of building exterior (Example 1) Figure 6. Home page with floor plan graphic (Example 2) BAS-PRC031-EN, 28 Jul 2010 10

Product Introduction Figure 7. Equipment status graphic (Example 3) 11 BAS-PRC031-EN, 28 Jul 2010

Product Introduction Tree Layout The Tree Layout tool allows you to build a navigation tree in the user interface. A navigation tree provides an alternate way to navigate through the user interface. A navigation tree appears as a separate window on top of the page currently in view (see Figure 8). The navigation tree consists of nodes, display text, and icons. You build the tree by choosing display text for nodes, arranging the nodes, and assigning associated graphics to them. The graphics represent equipment and areas of the facility. Figure 8. Example of a navigation tree Backup and Restore Database changes made by other users are automatically reflected in the Tracer SC without the need for a central server. The system database can be archived or backed up for local or off-site storage of data if it is ever needed for restoring the system, in the event of a problem. Troubleshooting Security Tracer SC constantly evaluates all of the system parameters and reports abnormal conditions to the operator. Problems ranging from a communication failure caused by a broken wire to the failure of a sensor are automatically detected and reported to the Alarms and Events log (see p. 6). A sophisticated password system protects a Tracer system from unauthorized access. Each operator is assigned a role. Roles are defined by access rights. Several pre-defined roles can be selected from the Tracer SC interface. Operators have access only to those features which define their roles. Roles can also be customized. An operator with administrative-level security can access all information on the system and has the ability to alter passwords. BAS-PRC031-EN, 28 Jul 2010 12

Product Introduction Hardware Components The Tracer SC system controller is housed in a protective enclosure that makes it easy to access. Figure 9, p. 13, illustrates the parts and function of the device. Figure 9. Tracer SC system controller components LonTalk BACnet MS/TP LINK 1 BACnet MS/TP LINK 2 Intermodule connector (IMC) for power Intermodule connector (IMC) for power BACnet LEDs LonTalk LEDs Status LED Power button LonTalk service LED LonTalk service pin 7-segment display Ethernet LEDs USB port for service tool connection Rotary switches USB host (future) SD card port (future) Modem (future; currently not enabled) RS-232 serial connection (factory use only) Ethernet network connection 2 (supports TCP/IP) (recommended for direct connection to PC) Ethernet network connection 1 (supports BACnet and TCP/IP (recommended for building LAN connection) 13 BAS-PRC031-EN, 28 Jul 2010

Tracer Building Automation System A Tracer building automation system provides centralized building control through a single, integrated system. Climate, lighting, scheduling, energy consumption, air quality monitoring, and other controllable features of a facility can be programmed and managed by a Tracer building automation system for simple, consistent, and reliable operations. In addition to controlling any type of HVAC equipment, a Tracer building automation system can be connected to other building systems such as security systems and lab hood controls. These applications work together to maximize the comfort and security of people in the building, while minimizing energy use. Tracer System Architecture The control elements are distributed throughout the Tracer building automation system. system controller is at the highest level of control. Unitary equipment has unit controllers, which compose subsystems. All controllers on the system are integrated into a network for communication and monitoring. In a Tracer building automation system, control is distributed to the following three levels to ensure integrity, as shown in Figure 10, p. 14: User interface control System control Unit control Figure 10. Tracer building automation system architecture LonTalk unit controllers (Complete list is on on p. 15) BACnet unit controllers (Complete list is on p. 15) Ethernet WAN/LAN (BACnet/IP) JENEsys BAS bridge Tracer SC PC with Web browser 14 BAS-PRC031-EN, 28 Jul 2010

Tracer Building Automation System User Interface Control System Control The Tracer SC user interface is viewed and operated from a Web-enabled PC. The user interface provides the ability for a building operator to configure, monitor, and modify system operations at the highest level of control (see User Interface, p. 5, for details.) Commands communicated from this control level can override automatic system-level control functions and some unit-level control functions. The Tracer SC system controller communicates with all unit controllers, acting as the central coordinator for all individual equipment devices. It gathers data from unit controllers, schedules and coordinates equipment operations, monitors for abnormal situations, and performs other miscellaneous building management and system-level functions. The Tracer SC system controller is designed to function automatically, without intervention of commands from the operator interface control level. The Tracer SC supports the JENEsys BAS bridge, which enhances system integration by providing a communication bridge between competitive proprietary protocols or other protocols such as Modbus. Unit Control Unit controllers provide all necessary unit control functions. They operate associated unitary equipment, while ensuring that all built-in safety features are enabled and that diagnostics are issued. Each controller is designed to operate in stand-alone mode. Therefore, if system control fails, unit operation can continue. Each Tracer SC can support a maximum quantity of 120 unit controllers. Unit controllers installed on a Tracer SC can be a combination of the following BACnet and LonTalk unit controllers. Notes: Three types of product licenses are available for the Tracer SC. They are based on the maximum number of unit controllers that each Tracer SC supports: 30, 60, or 120. BACnet controllers cannot exceed 60 controllers per link or 120 total controllers per Tracer SC. Of the total number of unit controllers on the LonTalk link, the number of MP580/581s cannot exceed 20. BACnet (MS/TP) unit controllers supported by Tracer SC Tracer SC systems support the following BACnet (MS/TP) unit controllers: Tracer UC400 unit controller for variable-air-volume (VAV) equipment Tracer UC400 unit controller for programmable equipment Tracer UC800/AdaptiView unit controller for CenTraVac chillers BCI-I: BACnet communications interface for IntelliPak system BCI-C: BACnet communications interface for chillers Non-Trane BACnet (MS/TP) devices LonTalk unit controllers supported by Tracer SC Tracer SC systems support the following Trane unit controllers: Tracer AH540/541 air-handler controller Tracer MP501 multi-purpose controller 15 BAS-PRC031-EN, 28 Jul 2010

Tracer Building Automation System Service Tools Tracer MP503 input/output module Tracer MP580/581 programmable controller Tracer VV550/551 VAV controller Tracer ZN510/511 zone controller Tracer ZN517 unit controller Tracer ZN520/521 zone controller Tracer ZN523 zone controller Tracer ZN524 water-source heat pump unit controller Tracer ZN525 zone controller Tracer CH530 chiller controller Tracer CH532 chiller controller LCI-C: LonTalk communications interface for chillers LCI-I: LonTalk communications interface for IntelliPak systems LCI-R: LonTalk communications interface for ReliaTel systems Non-Trane LonTalk devices using SCC, DAC, and chiller profiles; and devices supporting LonTalk standard network generic variables Two service tools are available for the support of unit controllers and for additional functions on systems using Tracer SC: The Tracer TU Service Tool Use the Tracer TU service tool: For configuring BACnet unit controllers For downloading Tracer SC software updates For obtaining data file from Tracer SC for use in creating TGP2 programs, and for accessing the TGP2 editor For accessing the Tracer Graphics Editor (TGE), which is used to copy graphics files to the Tracer SC and to edit them. As an additional way to backup and restore data to Tracer SC The Rover Service Tool Use the Rover Version 7 service tool: For configuring LonTalk unit controllers For setting the Tracer SC LonTalk network address To discover unit controller and the Tracer SC BAS-PRC031-EN, 28 Jul 2010 16

Resources The following resources are available for managing Tracer building automation systems: Tracer SC Installation, setup, and operation Tracer SC System Controller Version 2 Installation and Setup Guide (BMTW-SVX31) Tracer SC online help Tracer SC Installation Instructions (X39641100) Unit Controller Wiring Guide for the Tracer SC System Controller (BAS-SVN03) Programming Tracer Graphical Programming (TGP2) Editor Tracer Graphical Programming (TGP2) Application Guide (BAS-APG008) and online help HVAC applications Tracer SC Air Systems Application Guide (BAS-APG007) Tracer SC Chiller Plant Control Application Guide (BAS-APG012) Service tools Tracer TU Tracer TU Service Tool Getting Started Guide (TTU-SVN01) and online help Rover Version 7 Operation and Setup Guide (EMTX-SVX01) and online help Graphics support Centralized Services Tracer Graphics Editor (TGE): launches from within the Tracer TU service tool (with online help) Tracer TU Service Tool Getting Started Guide (TTU-SVN01) Software updates Tracer TU Service Tool Getting Started Guide (TTU-SVN01) Web sites MyTraneControls.com: A free online Web site designed to assist Tracer building automation system owners and operators. Tracer BAS training courses The Trane College of Building Automation offers a comprehensive portfolio of technical courses on the operation, installation, and programming of Tracer building automation systems. Refer to http://trane.com/commercial/dna/view.aspx?i=586. Service, maintenance, troubleshooting In addition to the resources listed above: Trane Product Support Warranty information BAS-PRC031-EN, 28 Jul 2010 17

Specifications This section contains specifications for Tracer SC system controllers and for Tracer building automation systems. Computer Tracer SC system controller Browser requirements Software requirements Power requirements Operating environment Storage environment Enclosure (optional) Weight Mounting UL listing FCC Internet Explorer Version 7.0 or higher, or Mozilla Firefox Version 3.0 or higher Java SE Runtime Environment (JRE) Version 5.0 (preferred: Version 6 Update 10 or higher) Adobe Flash player Internet Explorer Version 7.0 or higher or Mozilla Firefox Version 3.0 or higher USB driver For service tool connection and for direct access to Tracer SC Web pages Nominal rating: 120/230 Vac; 50 or 60 Hz; 1 ph Maximum current: 6.0 A at 120 Vac dedicated circuit breaker Temperature: From 40 F to 122 F ( 40 C to 50 C) Relative humidity: From 10% to 90%, non-condensing Temperature: From 40 F to 158 F ( 40 C to 70 C) Relative humidity: From 5% to 95%, non-condensing NEMA-1 14 lb (6.5 kg) Wall-mounted with #10 (5 mm) screws and #10 wall anchors Mounting surface must be able to support 60 lb (28 kg) UL-916-PAZX energy management CUL-C22.2 signal devices Canada FCC part 15, Class A CE Emissions Immunity Safety EN61326:1998 Class B EN61326:1998 Commercial EN61010-1:2001 Processor PowerPC405 Core Memory FLASH SDRAM 500 MB 256 MB System Communication Battery BACnet LonTalk No battery required. The clock is maintained for a minimum of three days by the super capacitor. All other programs are backed up by nonvolatile memory. Tracer building automation systems communicates with BACnet devices that support: Communications based on the BACnet ASHRAE/ANSI 135 standard ENV-1805-1/ENV-13321-1 10BASE-T/100BASE-TX dedicated Ethernet (ISO/IEC 8802-3) or Transmission Control Protocol/Internet Protocol (TCP/IP) compatible network Note: Non-Trane BACnet devices will be supported in a 2010 product release. Tracer building automation systems communicates with LonTalk devices that support: Communications based on the EIA-709.1 (LonTalk) standard LonTalk standard network variable types (SNVTs) FTT-10A or FT-X1 transceivers Twisted-pair physical media (Level 4 wiring) Note: Limited support for non-trane LonTalk devices will be implemented in the July 2009 product release. 18 BAS-PRC031-EN, 28 Jul 2010

Specifications Dimensions for the Tracer SC Enclosure (optional) Ø1.13 in (28.6 mm) + Ø1.38 in (34.9 mm) KNOCKOUT Ø.88 in (22.2 mm) KNOCKOUT 3.13 in (80 mm) 14.75 in (373 mm) 2.25 in (56 mm) 16.5 in (418 mm) 15 in (381 mm) 5.5 in (140 mm) Ø1.13 in (28.6 mm) + Ø1.38 in (34.9 mm) KNOCKOUT 13.25 in (337 mm) 19 BAS-PRC031-EN, 28 Jul 2010

Specifications Minimum Clearances for the Tracer SC Enclosure (optional) 12 in. (30 cm) 36 in. (90 cm) 24 in. (60 cm) 12 in. (30 cm) 12 in. (30 cm) 50 in. (130 cm recommended) Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.trane.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. 2010 Trane All rights reserved BAS-PRC031-EN, July 28, 2010 Produced on 20% post-consumer recycled paper, using environmentally friendly print practices that reduce waste.