Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting



Similar documents
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Automatic Bypass Control AVDO

Butterfly Valves PN 6/10/16 for flanged connection

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Self-operated Temperature Regulators Temperature Regulator Type 1u

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

2- and 3-port valves with flanged connections, PN 10

QLM and QLD Series Three-port Control Valves

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Thermostatic Actuators

Assisted lift operated 2/2-way solenoid valves Type EV250B

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Thermostatic element RAVV for 2-way valves

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Water valves REFRIGERATION AND AIR CONDITIONING. Fitters notes

Series description: Wilo-Yonos MAXO-D

SISTO-16TWA/HWA/DLU. Type Series Booklet

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Type 3353 Angle Seat Valve

Type and Type Pneumatic Control Valves Type 3510 Micro-flow Valve

Series description: Wilo-Yonos MAXO

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Thermostatic valve Type AVTA

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Automatic balancing valves ASV

Overview of types. Technical data

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

PRESSURE REDUCING CONTROL VALVE

MFP14, MFP14S and MFP14SS Automatic Pumps

Type overview. Technical data

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Digital inductive conductivity transmitter

kymanual or Automatic - it s your Choice

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

TN2000 Series Pneumatic Piston Actuators for DN125 to DN300 SPIRA-TROL Series Control Valves

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

Pressure regulating valve with modulating kit, type DRV

INLINE SD-PUMPS WITH IEC-STANDARD MOTOR

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

1805 Series Relief Valves

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Solenoid valves Type EVU

V47 Series Temperature Actuated Modulating Water Valves

REGULATORS 175/153 Series

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

PRESSURE REDUCING VALVES

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Direct steam injection humidifiers

ARI-DP30 / DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP Pneumatic actuator ARI-DP

Materials : Cast iron body

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

Vacuum Gate Valve DN 100 and DN 150

API Flanged Safety Relief Valves Series 526 CATALOG

Baumann Little Scotty Bronze Control Valve

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Types 66R and 66RR Low-Pressure Relief Valves

VAG Non-Return Valves

Solenoid valves 2/2-way direct-operated Type EV210A

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

RUBBER SLEEVE KNIFE GATE VALVE

stainless steel pre-assembled manifolds

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

4/2-Way Pneumatic Solenoid Valve

Stainless Steel Single and Dual Circulation Kits

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2- and 2/2-way cartridge valve type BVE

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

ARI-ASTRA / ASTRA Plus Combinend flow regulating valve

Cable Plug acc. to DIN EN , Form A

Baumann Way Bronze or Stainless Steel Control Valve

Overflow valve with thread connection

AURORA AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES

POWERS Controls No. 4 Pneumatic Damper Actuator

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

1.1 Z 011-A WAFER PATTERN BUTTERFLY TYP Z 011-A TECHNICAL DATA

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

TECHNICAL BULLETIN. Kämmer LinedFlow Corrosive Application Valves. Experience In Motion FCD KMENTB /12

P.E.D. 97/23/EC/0424 Butterfly Valves Series SL, SLK Group 1-2 Class I, II, III ATEX CE Ex II 2 GD

Products no longer available

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Transcription:

Data sheet Flow controller with integrated control valve (PN 16, 5, 40*) AFQM, AFQM 6 - return and flow mounting Description AFQM 6 DN 40, 50 AFQM DN 65-15 AFQM DN 150-50 AFQM(6) is a self-acting flow controller with integrated control valve primarily for use in district heating systems. The controller closes when set max. flow is exceeded. In combination with Danfoss electrical actuators AMV(E) can be controlled by EC electronic controllers. The controller has a control valve with adjustable flow restrictor, connection neck for electrical actuator and an actuator with one control diaphragm. Further on control valve can be: - not pressure relieved (AFQM 6 DN 40-50) or - pressure relieved (AFQM DN 65-50). Controllers are used together with Danfoss electrical actuators: AFQM 6 PN 16/5, AFQM PN5 DN 40-80 - AMV(E) 410 1) manual operation: - AMV(E) 65x + adapter 065B357 spring return function: - AMV(E) 413 1) - AMV(E) 658 SD ) + adapter 065B357 AFQM PN 5 DN 65-15 - AMV(E) 610 1) - AMV(E) 65x + adapter 065B357 spring return function: - AMV(E) 613 1) spring return function and manual operation: - AMV(E) 613 H 1) - AMV(E) 658 SD ) + adapter 065B357 1) in a discontinuing process ) not DIN approved AFQM PN 16 DN 65-15 with - AMV(E) 55, 56, - AMV(E) 65x AFQM PN 16 DN 150-50 with - AMV(E) 85, 86 AFQM 6 and AFQM PN 5 combined with AMV(E) 413 or AMV(E) 613 have been approved according to EN 14597. Main data: DN 40-50 k VS 0-400 m 3 /h Flow range,-40 m 3 /h PN 16, 5 * PN 40 on special request Flow restrictor p b : 0, or 0,5 bar Temperature: - Circulation water / glycolic water up to 30 %: 150 C for DN 40-15 140 C for DN 150-50 Connections: - Flange VD.R.A5.0 Danfoss 1/013 1

Ordering Example: Flow controller with integrated control valve, DN 65, k VS 50, PN 16, flow restrictor Δp b 0, bar, t max 150 C, flange - 1 AFQM DN 65 controller Code No.: 003G6056 AFQM 6 Controller Picture DN k VS m 3 /h PN Connection Code No. 40 0 003G108 16 50 3 003G1083 Flange EN 109-1 40 0 003G1084 5 50 3 003G1085 The controller will be delivered completely assembled, inclusive impulse tubes between valve and actuator. Electrical actuator AMV(E) must be ordered separately. AFQM Controller Picture DN k VS Code No. PN Connection (m 3 /h) ΔP b =0, bar ΔP b =0,5 bar 65 50 003G6056 003G6063 80 80 003G6057 003G6064 100 15 003G6058 003G6065 15 160 16 003G6059 003G6066 150 80 003G6060 003G6067 00 30 Flange EN 109-1 003G6061 003G6068 50 400 003G606 003G6069 65 50 003G1088 80 80 003G1089 5 100 15 003G1090 15 160 003G1091 Service kits Picture Type designation DN k VS (m 3 /h) Code No. Valve insert 65/80 50/80 065B794 100/15 15/160 065B795 Control valve insert 65 50 065B97 80 80 065B973 Type designation For controller Δp b (bar) Code No. AFQM 6 003G104 0, Actuator 003G106 AFQM 0,5 003G107 VD.R.A5.0 Danfoss 1/013

Technical data AFQM 6 valve Nominal diameter DN 40 50 k VS value Range of max. flow setting 0 3 from m 3 /h, 3, p 1) b = 0, bar to 11 16 Stroke mm 8 1 Control ratio > 1:0 Control characteristic inear Cavitation factor z 0,55 0,5 eakage acc. to standard IEC 534 % of k VS 0,01 Nominal pressure PN 16, 5 Min. differential pressure see remark ) Max. differential pressure PN 16 bar 16 Max. differential pressure PN 5 0 Medium Circulation water / glycolic water up to 30% Medium ph Min.7, max.10 Medium temperature C 150 Connections Materials Valve body PN 16 PN 5 Flange Grey cast iron EN-GJ-50 (GG-5) Ductile cast iron EN-GJS-400-18-T (GGG-40.3) Valve seat DP, CV Stainless steel mat. No. 1.401 Valve cone DP, CV Stainless steel mat. No. 1.4404 Sealing DP Sealing CV Pressure relieve system EPDM Metal Control valve insert - Valve insert Bellows (Stainless steel mat. No. 1.4571) Note: DP - diff. pressure controller, CV - control valve 1) p b - differential pressure over flow restrictor ) Depends on the flow rate and valve k VS ; For Q set = Q max -> p min 0,5 bar; For Q set < Q max -> p AFQM 6 Actuator min Q k VS pb For valve DN 40 50 Actuator size cm 50 Max. operational pressure 5 bar Flow restrictor diff. pressure ΔP b 0, Materials Housing Stainless steel M. No. 1.0338 Diaphragm Impulse tube EPDM (Rolling; fibre enforced) Stainless steel tube Ø10 0,8 mm VD.R.A5.0 Danfoss 1/013 3

Technical data (continuous) AFQM valve Nominal diameter DN 65 80 100 15 150 00 50 k VS value m 3 /h 50 80 15 160 80 30 400 Range of max. flow setting p b 1) = 0, bar p b 1) = 0,5 bar from 5.6 8,0 1,6 16 30 38 56 to 8 40 63 80 145 190 80 m 3 /h from 5.6 8,0 1,6 16 30 38 56 to 40 58 76 91 0 85 40 Stroke mm 1 18 0 5 7 Control ratio > 1:0 > 1:5 > 1:30 Control characteristic inear Cavitation factor z 0,5 0,4 0,35 0,3 0,3 0, 0, eakage acc. to standard IEC 534 % of k VS 0,01 Nominal pressure PN 16, 5 16 Min. differential pressure see remark ) Max. differential pressure PN 16 bar 16 16 15 15 1 10 10 Max. differential pressure PN 5 0 0 15 15 1 10 10 Medium Circulation water / Glycolic water up to 30 % Medium ph Min.7, max.10 Medium temperature C 150 140 Connections Materials Valve body PN 16 Flange Grey cast iron EN-GJ-50 (GG-5) PN 5 Ductile iron EN-GJS-400-18-T (GGG-40.3) - Valve seat DP, CV Stainless steel M. No. 1.401 Valve cone DP, CV Stainless steel mat No. 1.4404 Stainless steel mat. No. 1.401 Sealing DP, CV Pressure relieve system Control valve insert Valve insert Bellows (stainless steel mat No. 1.4571) EPDM Piston Diaphragm (EPDM) Note: DP - diff. pressure controller, CV - control valve 1) p b - differential pressure over flow restrictor ) Depends on the flow rate and valve k VS ; For Q set = Q max -> p min 0,5 bar; For Q set < Q max -> p AFQM actuator min Q k VS pb For valve DN 65 80 100 15 150 00 50 Actuator size cm 50 Max. operational pressure 16 or 5 bar Flow restrictor diff. pressure p b 0, or 0,5 Materials Housing Stainless steel M. No. 1.0338 Diaphragm Impulse tube EPDM (Rolling; fibre enforced) Stainless steel tube Ø10 0,8 mm 4 VD.R.A5.0 Danfoss 1/013

Application principles - Return mounting Direct-connected heating system Indirectly connected heating system - Flow mounting Direct-connected heating system Indirectly connected heating system Installation positions DN 40-80 T max 10 C The controllers can be installed with (connection neck for) electrical actuator oriented horizontal or upwards. DN 40-80 T max 10 C DN 40-80 T max > 10 C DN 100-50 The controllers can be installed with (connection neck for) electrical actuator oriented upwards. DN 40-80 T max > 10 C DN 100-50 VD.R.A5.0 Danfoss 1/013 5

Pressure temperature diagram PN 16 working area EN-GJ-50 (GG-5) PN 5 working area EN-GJS-400 (GGG-40.3) Maximum allowed operating pressure as a function of medium temperature (according to EN 109-) Flow diagram Sizing and setting diagram Relation between actual flow and number of revolutions on flow restictor. Values given are approximate. DN 50 k VS 400 DN 150 k VS 80 DN 00 k VS 30 DN 15 k VS 160 DN 100 k VS 15 DN 80 k VS 80 DN 65 k VS 50 DN 50 k VS 3 DN 40 k VS 0 1 = 360º Flow can be adjusted by turning flow restrictor screw counter-clockwise as shown in this diagram Water flow shown at differential pressure across flow restrictor 0, bar (0 kpa) and across the controller from 0,5 bar (50 kpa) to max. diff. pressure. 6 VD.R.A5.0 Danfoss 1/013

Flow diagram Sizing and setting diagram Relation between actual flow and number of revolutions on flow restictor. Values given are approximate. DN 50 k VS 400 DN 00 k VS 30 DN 150 k VS 80 DN 15 k VS 160 DN 100 k VS 100 DN 80 k VS 80 DN 65 k VS 50 1 = 360º Flow can be adjusted by turning flow restrictor screw counter-clockwise as shown in this diagram Water flow shown at differential pressure across flow restrictor 0,5 bar (50 kpa) and across the controller from 0,5 bar (50 kpa) to max diff. pressure. VD.R.A5.0 Danfoss 1/013 7

Sizing - Directly connected heating system Example 1 Motorised control valve (MCV) for mixing circuit in direct-connected heating systems requires differential pressure of 0, bar (0 kpa) and flow less than 8000 l/h. Given data: Q max = 8,0 m 3 /h (8000 l/h) p min = 0,8 bar (80 kpa) 1) p circuit = 0,1 bar (10 kpa) p MCV = 0, bar (0 kpa) selected Remark: 1) p circuit corresponds to the required pump pressure in the heating circuit and is not to be considered when sizing the AFQM. The total (available) pressure loss across the controller is: p AFQM,A = p min p AFQM,A = 0,8 bar (80 kpa) Possible pipe pressure losses in tubes, shut-off fittings, heatmeters, etc. are not included. Select controller from flow diagram, page 7, with the smallest possible k VS value considering available flow ranges. k VS = 0 m 3 /h The min. required differential pressure across the selected controller is calculated from the formula: p AFQM,MIN Q k max VS p p AFQM,MIN = 0,36 bar (36 kpa) p AFQM,A > p AFQM,MIN 0,8 bar > 0,36 bar MCV 8,0 0 0, Solution: The example selects AFQM 6 DN 40, k VS value 0, flow setting range,-11 m 3 /h. VD.R.A5.0 Danfoss 1/013 8

Sizing (continuous) - Indirectly connected heating system Example Motorised control valve (MCV) for indirectly connected heating system control requires differential pressure of 0, (0 kpa) bar and flow less than.000 l/h. Given data: Q max = m 3 /h (.000 l/h) p min = 0,8 bar (80 kpa) p exchanger = 0,1 bar (10 kpa) = 0, bar (0 kpa) selected p MCV The total (available) pressure loss across the controller is: p AFQM,A = p min p exchanger = 0,8 0,1 p AFQM,A = 0,7 bar (70 kpa) Possible pipe pressure losses in tubes, shut-off fittings, heatmeters, etc. are not included. Select controller from flow diagram, page 7, with the smallest possible k VS value considering available flow ranges. k VS = 50 m 3 /h The min. required differential pressure across the selected controller is calculated from the formula: p AFQM,MIN Q k max. VS p p AFQM,MIN = 0,39 bar (39 kpa) p AFQM,A > p AFQM,MIN 0,7 bar > 0,39 bar MCV 50 0, Solution: The example selects AFQM DN 65, k VS value 50, flow setting range 5.6-8 m 3 /h. VD.R.A5.0 Danfoss 1/013 9

Design 1. Valve body. Control valve insert 3. Adjustable flow restrictor 4. Control valve stem 5. Valve seat 6. Actuator 7. Control diaphragm for flow control 8. Built-in spring for flow rate control 9. Excess pressure safety valve 10. Valve insert 11. Pressure relieved valve cone 1. Valve stem 13. Bellows for pressure relief of valve cone 14. Diaphragm for pressure relief of valve cone 15. Impulse tube 16. Union nut 17. Upper casing of diaphragm 18. ower casing of diaphragm 19. Cover 0. Bellows for pressure relieve of control valve cone 10 19 15 17 4 3 1 5 11 13 1 15 16 8 6 7 18 PN 5 PN 16 19 15 17 4 0 1 3 5 11 10 13 1 15 16 8 6 9 7 18 AFQM 6 DN 40, 50 AFQM DN 65-15 AFQM DN 150-50 Function Flow volume causes pressure drop across the adjustable flow restrictor. Resulting pressures are being transferred through the impulse tubes to the actuator chambers and act on control diaphragm for flow control. The flow restrictor diff. pressure is controlled and limited by means of built-in spring for flow control. Control valve closes on rising differential pressure and opens on falling differential pressure to control max flow. Additionally the electrical actuator will operate from zero to set max. flow according to the load. Controller AFQM is equipped with excess pressure safety valve, which protect control diaphragm for flow control from too high differential pressure. VD.R.A5.0 Danfoss 1/013 10

Settings Flow setting Flow setting is being done by the adjustment of the flow restrictor position. The adjustment can be performed on the basis of flow adjustment diagram (see relevant instructions) and/or by the means of heat meter. Dimensions H 1 H 3 H 4 AMV(E) 410/AFQM 6 DN 40, 50 AMV(E) 413/AFQM 6 DN 40, 50 AMV(E) 65X/AFQM 6 + adapter 065B357 DN H 1 H 3 H 4 Valve weight mm (kg) 40 00 538 390 588 716 17 50 30 538 390 588 716 VD.R.A5.0 Danfoss 1/013 11

Dimensions (continuous) H 1 H 3 H 4 H 5 H 6 H 7 AMV(E) 410/AFQM DN 65-80, PN 5 AMV(E) 413/AFQM DN 65-80, PN 5 AMV(E) 61X/AFQM DN 65-15, PN 5 AMV(E) 55, 56/AFQM DN 65-15, PN 16 AMV(E) 65X/AFQM DN 65-15, PN 16 AMV(E) 65X/AFQM DN 65-15, PN 5 + adapter 065B357 H 1 DN H 1 H 3 H 4 H 5 H 6 H 7 Valve weight (kg) mm PN 16 PN 5 65 90 600 45 650 685 650 775 819 5 58,5 80 310 610 45 660 695 670 785 89 61 60,5 100 350-530 - 715 680 805 849 93,6 96 15 400-530 - 740 710 830 874 117, 139 AMV(E) 85, 86/AFQM DN 150-50, PN 16 DN H 1 Valve weight mm (kg) 150 480 576 455 14 00 600 65 483 19 50 730 656 533 34 1 VD.R.A5.0 Produced by Danfoss A/S 1/013