Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7



Similar documents
Reference Guide. Vantage PRO2 Quick

WeatherLink for Vantage Pro and Vantage Pro2

WeatherLink for Alarm Output. Introduction. Hardware Installation and Requirements. Addendum

WeatherLink for Vantage Pro and Vantage Pro2

NC-12 Modbus Application

IntesisBox Modbus Server Fidelio IP

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IntesisBox Modbus Server SAMSUNG Air Conditioners

Modbus Server SAMSUNG Air Conditioners

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

PowerLogic Sub Meter Display (SMD and SMDOPN)

IntesisBox ASCII Server - LON

8. Barometric Trend Arrow 9. Graph Icon 10. Current Rain Icon 11. Station Number Indicator 12. Weather Ticker 13. Graph Field 14.

Section TELEPHONE AUTOMATIC DIALER SYSTEM

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

For more detailed information, see your Vantage Vue Console manual.

Network Operation and Troubleshooting

Introduction: Implementation of the MVI56-MCM module for modbus communications:

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Estação Meteorológica sem fio VEC-STA-003

For support on the Beijer HMI please contact:

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

PLC Master / Slave Example

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Bluetooth HC-06 with serial port module Easy guide

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

USER MANUAL. Console. For Vantage Pro2 and Vantage Pro2 Plus

s!nus-elektrotechnikai bt. Industrial IT & Automation

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

Wireless Vantage Pro 2 & Vantage Pro Plus 2 Stations

Modbus Communications for PanelView Terminals

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

1 Application Description Objective Goals... 3

Vantage Pro2 Console Manual. For Vantage Pro2 & Vantage Pro2 Plus Weather Stations

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Cabled Vantage Pro2 & Vantage Pro2 Plus Stations

WEB log. Device connection plans

IntesisBox KNX Modbus RTU master

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

MODBUS TCP to RTU/ASCII Gateway. User s Manual

EXPLANATION OF WEATHER ELEMENTS AND VARIABLES FOR THE DAVIS VANTAGE PRO 2 MIDSTREAM WEATHER STATION

EZ-View Network Communications Guide

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

1. SAFETY INFORMATION

PCS0100en Persy Control Services B.V. Netherlands

TX2123 RS485 TO ETHERNET ADAPTOR

One Port Serial Server Users Manual Model ESP901, ESP901E

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Vantage Pro2 Temperature/Humidity Sensor Replacement Kit

1000 Series Data Loggers PRODUCT MANUAL

MODBUS TCP to RTU/ASCII Gateway

KOYO DIRECT. HMI Setting: PLC Setting: Supported Series: KOYO DirectLogic series PLC DL05, DL06, DL105, DL205, DL305, and DL405 series.

IP Link Device Interface Communication Sheet

PLC training panel (Twido version)

Modbus and ION Technology

User Manual. Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)

WeatherLink for Emergency Response Teams Addendum

POS Integration. Prepared by: Binh Nguyen

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

OPT SERIAL TO FIBER OPTIC CONVERTER

Single channel data transceiver module WIZ2-434

RcWare SoftPLC Modbus server mapping editor User manual

SCADALink DC100 Data Concentrator

WEATHER STATION FOR SOLAR FARM MONITORING

WEB log. Device connection plans

USING WIRELESS DIAGNOSTICS Application Note 31

Setup of an internet enabled Davis Vantage Pro2 weather station using a Raspberry Pi Zeist Hoge Dennen October 2014

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

User manual Compact Web PLC WP240 series IEC-line

Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) Manual Rev A + - DLM CTS RTS DTR DSR

Cable Pinouts. SRP I/O Module

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

How To Set Up A Protocessor Protonode

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Application Note. Positioning with Dimetix distance sensor and SEW inverter FLS-C

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Wireless Soil Moisture and Weather Monitoring System Caipos

Paragon Explorer Lite Communication Software

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Vaisala Weather Transmitter WXT510 The Most Essential of Weather

Bluetooth to Serial Adapter

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

LBNP RS-232/485/422 serial device server. User manual

T3 Mux M13 Multiplexer

Network-wide Diagnostics

IntesisBox Modbus Server - Mitsubishi Electric G50

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

IP Link Device Interface Communication Sheet

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

How to setup a serial Bluetooth adapter Master Guide

Rev GSM base station. Installation instructions

VOICE RECORDING SYSTEM ISDN PRI / BRI

Vue. Davis Instruments, 3465 Diablo Avenue, Hayward, CA U.S.A

A-Series Data Loggers PRODUCT MANUAL

Connecting the Console Port to a PC

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

Using HyperTerminal with Agilent General Purpose Instruments

Transcription:

1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote Telemetry Unit) or SCADA system to a Davis Instruments Vantage Pro2 weather station. Using the Modbus RTU (binary) protocol it enables your programmable controller to monitor and carry out actions based on wind speed, wind direction, temperature and many other weather-based variables. The Gateway is linked to the weather station s RS-232 serial connection. The Gateway polls the weather station for its readings every 10 seconds. These readings are then stored in the Modbus holding registers in the Gateway. The PLC or RTU acting as a Modbus master is able to use the Modbus function 3 to read the contents of the Gateway's holding registers, which will contain the latest weather readings. 2. Features PLC or RTU connects to Gateway COM Port 1, RS-232 or RS-485 connection. VantagePro2 weather station connects to Gateway RS-232 COM Port 2 with baud rate 19200. PLC or RTU connection features: - Selectable Modbus address from 1 to 16. - Selectable baud rate from 2400, 4800, 9600 to 19200. - Selectable parity none, odd, even. LED indication of transmit and receive communications between the weather station and Gateway and between PLC or RTU and Gateway. Weather station main readings are: - Outdoor Temperature - Outdoor Humidity - Indoor Temperature (console) - Indoor Humidity (console) - Wind Speed - Wind Direction - Rainfall (Precipitation) - Daily Rainfall - Monthly Rainfall

2 de 7 - Yearly Rainfall - Barometric Pressure and trend - Solar Radiation and UV - Evaporative Transfer * See the next section to find a complete list of the weather variables. Communications OK status shows the communications between the weather station and the Gateway is OK. 3. Modbus description The Gateway operates as a Modbus slave. To access the holding registers in the Gateway, the PLC or RTU must be configured as a Modbus master. Using Modbus function 3 the PLC or RTU can read the holding registers 1 to 60. NOTE: The PLC or RTU cannot read more than 30 registers at one time. To interrogate the full 60 holding registers two separate reads must be used. The following table shows the available holding registers in the Gateway: Holding No. Of Register Registers Address Description 1 1 Current 3-Hour Barometer Trend. 2 1 Packet Type, always 0 3 1 Location in the archive memory where the next data packet will be written. This can be monitored to detect when a new record is created. Multiplier Units 4 1 Barometer 0.001 inhg 5 1 Inside Temperature 0.1 degf 6 1 Inside Humidity 1 % 7 1 Outside Temperature 0.1 degf 8 1 Wind Speed 1 mph 9 1 10-Min Average Wind Speed 1 mph 10 1 Wind Direction 1 degrees 11 4 7 Extra Temperatures 0.1 degf 15 2 4 Soil Temperatures 0.1 degf 17 2 4 Leaf Temperatures 0.1 degf

3 de 7 19 1 Outside Humidity 1 % 20 4 7 Extra Humidity 1 % 24 1 Rain Rate 0.01 in/hr 25 1 UV Index 1 26 1 Solar Radiation 1 W/m2 27 1 Storm Rain 0.01 inches 28 1 Current Date of Storm Rain 0.01 inches 29 1 Daily Rain 0.01 inches 30 1 Monthly Rain 0.01 inches 31 1 Yearly Rain 0.01 inches 32 1 Daily ET 0.01 inches 33 1 Monthly ET 0.01 inches 34 1 Yearly ET 0.01 inches 35 2 4 Soil Moistures 1 centibars 37 2 4 Leaf Wetnesses 0 to 15 (0 = very dry / 15 = very wet) 1 39 1 Inside Alarms 1 40 1 Rain Alarms 1 41 1 Outside Alarms 1 42 4 Extra Temp/Hum Alarms 1 46 2 Soil and Leaf Alarms 1 48 1 Transmitter Battery Status 1 49 1 Console Battery Voltage 1 volts 50 1 Forecast Icons 1 51 1 Forecast Rule Number 1 52 1 Time of Sunrise 1 HHMM 53 1 Time of Sunset 1 HHMM 60 1 Communications Status (1 = OK / 0 = Fault) 1 Table 1. Variables and holding register addresses Holding Register 60 or Communications Status indicates if the Gateway is receiving data from the weather station. 4. Weather station setup The Davis Instruments Vantage Pro2 weather station must be fitted with a RS-232 serial interface. The Gateway includes an RJ-45 cable which has a 9 pin male DB-9 connector,

4 de 7 connect this to COM2 on the Gateway and the other end to the serial interface on the weather station. Ensure that the serial baud rate on the weather station is set to 19200 bauds. Ensure S2 is in the RS-232 position. NOTE: The weather station must have batteries or power supply fitted into its console. If power is lost to the weather station it will not respond to data requests from the Gateway. 5. Gateway setup Connect 9VDC to 15VDC to the screw terminals V+ and V-. For advanced wiring through the RJ-45 connectors refer to their pinout further in this Technical Note. If RS-232 is used to communicate with the Modbus master then the provided RJ-45 to DB-9 dongle can be used in COM1, if RS-485 is to be used a RJ-45 connector is required to be wired, refer to Table 5 for connections. Set the DIP switches on S3 on the Gateway to match the Modbus address, baud rate and parity of your system. NOTE: If DIP switches are altered while power is on then no change will take effect until power is re-applied. Next tables show the DIP switch configuration: Modbus Address Switch 1 Switch 2 Switch 3 Switch 4 1 OFF OFF OFF OFF 2 ON OFF OFF OFF 3 OFF ON OFF OFF 4 ON ON OFF OFF 5 OFF OFF ON OFF 6 ON OFF ON OFF 7 OFF ON ON OFF 8 ON ON ON OFF 9 OFF OFF OFF ON 10 ON OFF OFF ON

5 de 7 11 OFF ON OFF ON 12 ON ON OFF ON 13 OFF OFF ON ON 14 ON OFF ON ON 15 OFF ON ON ON 16 ON ON ON ON Table 2. Modbus addresses Baud Rate Switch 5 Switch 6 2400 OFF OFF 4800 ON OFF 9600 OFF ON 19200 ON ON Table 3. Modbus baud rate Parity Switch 7 Switch 8 None OFF OFF Even ON OFF Odd OFF ON None ON ON Table 4. Modbus parity Next figures show the connections diagrams of the board: Figure 1. Connections and switch locations

6 de 7 Figure 2. Port identification and LED locations Pin Name Function 1 VS V+ Power in 2 CM Common 3 RX RS-232 Receive 4 TX RS-232 Transmit 5 CM Common 6 D- RS-485 Data- 7 D+ RS-485 Data+ 8 CM Common Table 5. COM1 and COM2 pins 6. Troubleshooting LED's are provided to assist in troubleshooting. TX2 and RX2 should flash once every 10 seconds to indicate communication to the weather station is good. If TX2 is not flashing, check: 1. 12VDC is applied between V+ and V- terminals. If RX2 is not flashing, check: 1. The serial baud rate on the weather station is set to 19200.

7 de 7 2. The cable connections are OK. TX1 and RX1 LED s indicate communications to the PLC or RTU. If RX1 is not flashing, check: 1. If crossover on pins 2 and 3 (RX and TX) is needed. 2. Baud rate and parity DIP switches match baud rate and parity of PLC or RTU. If Tx1 is not flashing, check: 1. Modbus Address DIP switches are correct 2. Baud rate and parity DIP switches match baud rate and parity of PLC or RTU.