Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems



From this document you will learn the answers to the following questions:

What is the relevant application selected and what during commissioning?

What is the name of the device that operating mode switchover contact is used?

What mode is used for heating and cooling?

Similar documents
Flush-mounted room thermostats

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RRV934. Multi-controller. Synco living

VAV compact controller KNX / PL-Link

VAV compact controller KNX / PL-Link

TX OPEN RS232/485 module

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

RDG/RDF room thermostats

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Digital input modules

Adjustable room thermostat for heating only or cooling only systems

OZW30. Central Unit SYNERGYR

Drayton Digistat +2RF/+3RF

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Building Technologies

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

OZW V2.0. Web server. Synco TM, Synco TM living

Product and Application Description

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Controls for fan coil units and cassettes

HERZ-Thermal Actuators

IntesisBox KNX Mitsubishi Heavy Industries AC

Heating Controller. Building Technologies HVAC Products

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Duct Humidity Transmitter

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Inwall Room Temperature Unit

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

OZW V4.0. Web server. For Synco TM, Synco TM living

User Manual THR840DUK Digital Thermostat

Electronic Control Devices The European Product Catalogue 2007

Room Temperature Sensors

T5000 T000 LCD Digital Fan Coil Thermostat

Product and functional description

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Quick Connect. quick - simple - efficient.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Air damper actuators

Electronic Control Devices The European Product Catalogue 2007

3873P01. Room controllers. For fan-coil applications FC-10, FC-11, FC12 with Konnex bus communications (S-mode and LTE mode)

Voltage Regulator SPAU 341 C. Product Guide

KNX Panasonic Air Conditioners

OZS Web server. For LPB/BSB plants

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Flush-mount room temperature sensor AQR2531ANW.

15 Series - Electronic step relay and dimmer. Features SERIE

HVAC central apartment unit with consumption data acquisition

HMI display Installation Guide

CR24-.. Single room controllers

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

PXM20-E. Operator unit DESIGO PX

T0118 T2118 T3118. Instruction Manual

DC Electronic Loads 8500 series

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Power Meter Series 700

KNX. Siemens Building Technologies HVAC Products. Synco Konnex bus. For devices of the Synco 700 / RXB ranges

Accessories SUNNY REMOTE CONTROL

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

TMS TANK MANAGEMENT SYSTEM

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

PC Software for VAV compact and modular controllers

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

MOUNTING AND OPERATING INSTRUCTIONS

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

IntesisBox KNX Modbus RTU master

Thermostat with display

MasterINTERFACE 39 Series - Relay interface modules

OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

ABB i-bus KNX SA/S Switch Actuators Product Manual

Web-Server OZW V5.2

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

is then retained absolutely without interruption.

IntesisBox Modbus Server SAMSUNG Air Conditioners

T7560A,B,C Digital Wall Module

STRATO LED Drivers 70W, Single output

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

IntesisBox KNX LG Air Conditioning

CompactLogix Power Supplies Specifications

AXIS T81B22 DC 30W Midspan

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

A project to optimise quality and energy efficiency must include metering

IntesisBox KNX Modbus TCP master

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

Transcription:

s 3 72 Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems RDU34 KNX bus communications (S-mode and LTE mode) Backlit display PI / P control Outputs for DC 0 0 V actuator and AC 230V electrical heater (ON-OFF) Output signal inversion as an option (DC 0...0 V DC 0...0 V) 2 multifunctional inputs for keycard contact, external sensor, etc. Operating modes: Comfort, Economy and Protection Control depending on the room or the return air temperature Automatic or manual heating/cooling changeover Minimum and maximum limitation of room temperature setpoint Adjustable minimum and maximum limitation for air flow signal DC 0..0V Adjustable commissioning and control parameters Commissioning with Synco ACS700, ETS3 Professional or via local HMI Integration into Synco Integration into DESIGO and Apogee via group addressing (ETS3) or via individual addressing Integration into third-party system via group addressing (ETS3) Mounting on recessed rectangular conduit box, 60.3 mm fixing centers AC 24 V operating voltage CEN372en 0 Jun 200 Building Technologies

Use Room temperature control (heating or cooling) in individual rooms and zones by means of: Heated or cooled by single duct system Heated or cooled by single duct system with electrical heater. The RDU34 is suitable for use with VAV systems in connection with the VAV compact controllers, e.g. types G B8.E/3. The RDU34 controls One DC 0 0 V actuator One DC 0 0 V actuator and AC 230V -stage electrical heater Used in systems with: Heating or cooling mode Automatic heating/cooling changeover Manual heating/cooling changeover Heating and cooling single duct (single duct with electrical heater) The room thermostats are delivered with a fixed set of applications. The relevant application is selected and activated during commissioning using one of the following tools: Synco ACS ETS3 Professional (planned) Via local DIP switch and HMI Functions Maintain room temperature via built-in temperature sensor or external room temperature / return air temperature sensor Changeover between heating and cooling mode (automatic via local sensor or bus, or manual) Select application via DIP switches or commissioning tool (ACS700, ETS3 Professional) Select operating mode via operating mode button on the thermostat Temporary Comfort mode extension Display current room temperature or setpoint in C and/or F Minimum and maximum limitation of room temperature setpoint Minimum and maximum limitation of air flow signal DC 0...0 V Button lock (automatic and manual) Two multifunctional inputs, freely selectable for: Operating mode switchover contact (keycard) Automatic heating/cooling changeover sensor External room temperature sensor or return air temperature sensor Dewpoint sensor Electrical heater enable Fault input Monitor input for temperature sensor or switch status Reload factory settings for commissioning and control parameters KNX bus (terminals CE+ and CE-) for communication with Synco or KNX compatible devices Display of outdoor temperature or time of day via KNX bus 2 / 2

Time scheduling and central control of setpoints via KNX bus With a Synco RMB7xx or RMUxx controller, the air demand signal of the thermostat is used to optimize supply air temperature. Applications The thermostat supports the following applications, which can be configured using the DIP-switches on the inner side of the thermostat's front panel or a commissionning tool. All DIP switches need to be set to OFF (remote configuration, factory setting) to select an application via commissioning tool. Applications and control output DIP-switches Remote configuration via commissioning tool (factory setting) Synco ACS ETS3 professional (planned) ON 2 3 Single duct Single duct heating or cooling DC 0...0 V output signal normal ON Single duct heating or cooling DC 0...0 V output signal inverted ON 2 3 2 3 Single duct with electrical heater Single duct heating and cooling, with electrical heater DC 0...0 V output signal normal ON Single duct heating and cooling, with electrical heater DC 0...0 V output signal inverted ON 2 3 2 3 Type summary Product number Stock number Operating voltage Control outputs 3 pt on/off DC 0..0 V Housing color RDU34 S55770-T06 AC 24 V -- white Ordering When ordering, indicate both product number / stock number and name: E.g. RDU34 / S55770-T06 room temperature controller Order valve actuators separately. 3 / 2

Equipment combinations Type of unit Product no. Data sheet Cable temperature sensor QAH. 840 Room temperature sensor QAA32 747 DC 0 0 V actuators Condensation detector / Supply unit Electrical actuator, DC 0..0V (for radiator valve) Electrical actuator, DC 0..0 V (for 2 and 3 port valves / V P45) Electrical actuator, DC 0..0V (for small valve 2,5 mm) Electrical actuator, DC 0..0V (for small valves 5.5 mm) Electrical actuator, DC 0..0 V (for Combi-valve VPI45) Electromotoric actuator, DC 0..0V (for valves 5.5 mm) Thermal actuator, DC 0..0V (for small valves and radiator valves) QXA2000 / QXA200 / AQX2000 542 SSA6... 4893 SSC6 4895 SSP6 4864 SSB6... 489 SSD6... 486 SQS65 4573 STS6 4880 GQD6 4605 GDB6 GLB6 4634 DC 0 0 V damper actuator GMA6 464 GEB6 462 GCA6 463 VAV compact controller GBB6 GIB6 GDB8.E/3 GLB8.E/3 4626 3544 4 / 2

Accessories Type of unit Product number Data Stock number sheet Changeover mounting kit (50 pcs/package) ARG86.3 N3009 Plastic mounting bracket for semi-flush-mount N3009 thermostats for increasing the headroom in the conduit box by 0mm ARG70.3 Conduit box for semi-flush mounted thermostat ARG7 / N3009 S55770-T37 KNX Power supply 60 ma (Siemens BT LV) 5WG 25-AB0 -- KNX Power supply 320 ma (Siemens BT LV) 5WG 25-AB -- KNX Power supply 640 ma (Siemens BT LV) 5WG 25-AB2 -- Mechanical design The controller consists of 2 parts: Front panel with electronics, operating elements and built-in room temperature sensor. Mounting base with the power electronics. The rear of the mounting base contains the screw terminals. The base fits on a rectangular conduit box with 60.3 mm fixing centers. Slide the front panel in the mounting base and snap on. Operation and settings 2 Operating mode selector / Protection 2 Adjust setpoint and control parameters 5 / 2

Display 3 2 4 5 Operating mode Protection Comfort Economy Auto Timer according to schedule (via KNX) 2 Displays room temperature, setpoints and control parameters. Symbol indicates the current room temperature 6 7 8 9 0 3 Heating/cooling mode Cooling Heating, Electrical heater active 4 Additional user information, like outdoor temperature or time of day from KNX bus 5 Indicates fault or reminder 6 Condensation in room (dewpoint sensor active) 7 Temporary comfort prolong active 8 Primary fan is active (only supported with Synco700 primary controller) 9 Button lock active 0 Weekday 7 from KNX bus ( = Monday / 7 = Sunday) Engineering notes See the "Reference documentation", page for information on how to engineer the KNX bus (topology, bus repeaters, etc.) and how to select and dimension connecting cables for supply voltage and field devices. Mounting and installation Mount the room controller on a recessed rectangular conduit box with 60.3mm fixing centers. Do not mount on a wall in niches or bookshelves, behind curtains, above or near heat sources, or exposed to direct solar radiation. Mount about.5 m above the floor. Mounting Mount the room thermostat on a clean, dry indoor place without direct airflow from a heating / cooling device, and not exposed to drips or splash water. In case of limited space in the conduit box use the mounting bracket ARG70.3 to increase the headroom by 0mm 6 / 2

Wiring See the mounting instructions M372 enclosed with the controller. Comply with local regulations to wire, fuse and earth the controller. The AC 230 V mains cable and the AC 24 V supply line must have an external fuse or circuit breaker with a rated current of no more than 0 A. Isolate the cables of SELV inputs X-M/X2-M for 230 V if the conduit box carries AC 230 V mains voltage. Inputs X-M or X2-M of different units (e.g. summer/winter switch) may be connected in parallel with an external switch. Consider overall maximum contact sensing current for switch rating. Isolate the cables of KNX communication input CE+ / CE- for 230 V if the conduit box carries AC 230 V mains voltage. No metal conduits. No cables provided with a metal sheath. Disconnect from supply before opening the cover. Commissioning notes Applications The room thermostats are delivered with a fixed set of applications. Select and activate the relevant application is selected and activated during commissioning using one of the following tools: Local DIP switch and HMI Synco ACS ETS3 Professional (planned) Set the DIP switches before snapping the front panel to the mounting plate, if you want to select an application via DIP switches. All DIP switches need to be set to OFF ("remote configuration"), if you want to select an application via commissioning tool. After power is applied, the thermostat resets and all LCD segments flash, indicating that the reset was correct. After the reset, which takes about 3 seconds, the thermostat is ready for commissioning by qualified HVAC staff. If all DIP switches are OFF, the display reads "NONE" to show that an application needs to be set via tool. Note Each time the application is changed, the thermostat reloads the factory setting for all control parameters, except for KNX device and zone addresses! 7 / 2

Connect tool Connect the Synco ACS or ETS3 Professional tools to the KNX bus cable at any point for commissioning: KNX G X M X2 CE+ CE- KNX Siemens N48 / UP46 / UP52 KNX Siemens OCI700 G0 L Y2 Y0 G0 N V24 USB RS232 ETS ETS / ACS 372A04 ACS and ETS3 require an interface: RS232 KNX interface (e.g. Siemens N48 / UP46 / UP52) OCI700 USB- KNX interface Note An external KNX bus power supply is required if an RDU34 is connected directly to a tool (ACS or ETS3) via KNX interface. Control parameters The thermostat's control parameters can be set to ensure optimum performance of the entire system (see basic documentation P372). The parameters can be adjusted using Local HMI Synco ACS ETS3 Professional (planned) Control sequence Calibrate sensor Setpoint and range limitation The control sequence may need to be set via parameter P0 depending on the application. The factory setting for the single duct application is Cooling only. Recalibrate the temperature sensor if the room temperature displayed on the controller does not match the room temperature measured (after min. hour of operation). To do this, change parameter P05. We recommend to review the setpoints and setpoint ranges (parameters P08 P2) and change them as needed to achieve maximum comfort and save energy. Programming mode The programming mode helps identify the thermostat in the KNX network during commissioning. Press buttons operating mode and + simultaneously for 6 sec to activate programming mode, which is indicated on the display with "PrOg". Programming mode remains active until thermostat identification is complete. Assign KNX group addresses Use ETS3 Professional to assign the KNX group addresses of the RDU communication objects. 8 / 2

KNX serial number Each device has a unique KNX serial number inside the front panel. An additional sticker with the same KNX serial number is enclosed in the packaging box. This sticker is intended for installers for documentation purposes. Disposal This device is classified as waste electronic equipment under European Directive 2002/96/EC (WEEE) and may not be disposed of as unsorted municipal waste. Adhere to all relevant national laws. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. Technical data Power supply Operating voltage SELV AC 24 V +/-20 % Rated voltage AC 24 V Frequency 50/60 Hz Power consumption Max. 2.5 VA / 0.9 W Outputs Control output Y2-N (N.O.) Rating AC 230 V Max. 5(2) A Control output Y0-G0 Resolution Current SELV DC 0 0 V 39 mv Max. ma Inputs Multifunctional input X-M/X2-M Temperature sensor input: Type Digital input: Operating action Contact sensing Insulation against mains voltage (SELV) Function input: External temperature sensor, heating/cooling changeover sensor, operating mode switchover contact, dewpoint monitor contact, enable electrical heater contact, fault contact, monitor input QAH. (NTC) Selectable (N.O./N.C.) SELV DC 0...5 V/max 5 ma 4 kv, reinforced insulation Selectable X: P38 X2: P40 KNX bus Interface type KNX, TP-64 (electrically isolated) Bus current 20 ma Bus topology: See KNX manual (reference documentation, see below) Operational data Switching differential, adjustable Heating mode (P30) 2 K (0.5...6K) Cooling mode (P3) K (0.5...6K) Setpoint setting and range Comfort (P08) 2 C (5...40 C) Economy (P-P2) 5 C/30 C (OFF, 5...40 C) Protection (P65-P66) 8 C/OFF (OFF, 5...40 C) 9 / 2

Environmental conditions Standards and directives Multifunctional input X/X2 Input X default value Input X2 default value Built-in room temperature sensor Measuring range Accuracy at 25 C Temperature calibration range Settings and display resolution Setpoints Current temperature value displayed Operation Climatic conditions Temperature Humidity Transport Climatic conditions Temperature Humidity Mechanical conditions Storage Climatic conditions Temperature Humidity conformity EMC directive Low-voltage directive (P38) (P40) Selectable 0...8 3 (Operating mode switchover) (External temperature sensor) 0 49 C < ± 0.5 K ± 3.0 K 0.5 C 0.5 C As per IEC 72-3-3 Class 3K5 0...+50 C <95 % r.h. As per IEC 72-3-2 Class 2K3 25...+60 C <95 % r.h. Class 2M2 As per IEC 72-3- Class K3 25...+60 C <95 % r.h. 2004/08/EC 2006/95/EC C-tick conformity to EMC emission standard AS/NZS 6000.6.3: 2007 Reduction of hazardous substances 2002/95/EC Product standards Automatic electrical controls for household and similar use Special requirements for temperature-dependent controls Electronic control type EN 60730 EN 60730 2-9 2.B (micro-disconnection on operation) EN 50090-2-2 Home and Building Electronic Systems Electromagnetic compatibility Emissions (residential) IEC/EN 6000-6-3 Immunity (industrial and residential) IEC/EN 6000-6-2 Safety class II as per EN 60730 Pollution class Normal Degree of protection of housing IP 30 as per EN 60529 General Connection terminals Solid wires or prepared stranded wires x 0.4 2.5 mm2 or 2 x 0.4.5 mm2 Housing front color Weight without / with packaging RAL 9003 white 0.63 kg / 0.233 kg 0 / 2

Reference documentation Handbook for Home and Building Control - Basic Principles (www.knx.org/uk/news-press/publications/publications/) Synco CEP327 Communication via the KNX bus for Synco 700, 900 and RXB/RXL Basic documentation DESIGO CMY9775 DESIGO RXB integration S-mode CMY9776 DESIGO RXB / RXL integration individual addressing CMY9777 Third-party integration CMY9778 Synco integration CMY9779 Working with ETS Apogee Installation Instruction: KNX Driver for PXC Modular; Document No. 565-32 Technical Spec Sheet: KNX Driver for PXC Modular; Document No. 27-676 Technical Reference for KNX Driver; Document No. 40-0804 Application 6206 Point Map for RDU Connection terminals G X M X2 G0 L Y2 CE+ CE - Y0 G0 372A2 SELV G, G0 Operating voltage SELV AC 24 V L Supply for electrical heater AC 230 V X0, G0 Output for damper, VAV compact controller Y2 Output for electrical heater X, X2 Multifunctional input for temperature sensor (e.g. QAH.) or potential-free switch Factory setting: X = Operating mode switchover contact X2 = External sensor (function can be selected via parameter P38 / P40). M Measuring neutral for sensor and switch CE+ KNX data + CE- KNX data - Connection diagram G L N G0 F 0 A F 0 A AC 24V G S B X M X2 S2 B2 G0 L Y2 Y0 G0 E 5(2)A max. CE+ CE- Y KNX N 372A22 N Room thermostat RDU34 Y Damper actuator, VAV compact controller E Electrical heater F External fuse S, S2 Switch (keycard, window contact, etc.) B, B2 Temperature sensor (return air temperature, external room temperature, changeover sensor, etc.) CE+ KNX data + CE- KNX data - / 2

Dimensions Dimensions in mm 2 / 2 2009-200 Siemens Switzerland Ltd Subject to change