1 RDG/RDF room thermostats Application Guide Answers for infrastructure.
2 Application overview 2-pipe el. heater or radiator 4-pipe with el. heater Chilled/ heated ceiling Chilled/heated ceiling with el. heater 2-pipe Chilled/heated ceiling and radiator Fan coil unit Universal 2-stage heating or cooling Chilled ceiling and radiator Single duct Compressor for heating or cooling Single duct with el. heater Variable air volume (VAV) Heat pumps Compressor with el. heater Single duct and radiator Single duct with heat/cool coil 2-stage compressor for heating or cooling Compressor for heating and cooling 2
3 Contents Introduction... 4 Before you start...4 Description of RDG range... 4 Product range RDG... 4 Description of RDF.. semi flush-mount range...5 Product range RDF/RDU stand-alone...5 Product range RDF/RDU stand-alone with time program...5 Product range RDF/RDU with bus interface...5 Description of applications... 6 Extensive features and functions... 7 Fan coil application overview... 8 Fan coil product overview...10 Universal application overview Universal product overview Heat pumps application overview...15 Heat pumps product overview VAV application overview...18 VAV product overview How to prepare and set up your room thermostats...20 Introduction...20 Control parameters Installation and set up...20 Application-specific parameters...21 Communicating, KNX thermostats...22 Suggestions for energy saving FAQ...23 Reference to the basic documentation...23 Application examples
4 Introduction The RDG and RDF thermostat range is very versatile and includes a number of products. RDG and RDF offer extensive features and cover a broad range of applications. The document: provides you an overview of the new RDG and RDF ranges assists you in selecting the suitable product and provides helpful installation and commissioning information The section application overview for each main application i.e. fan coil unit (FCU, universal, heat pumps and VAV shows what applications are covered by which thermostat line. The sections product overview show the available thermostat variants and their supported applications. Before you start We recommend proceeding as follows prior to selecting a thermostat: Type of main application: FCU, universal, heat pump or VAV Application: e.g. 2-pipe with electric heater Type of control output 1: ON/OFF, PWM, 3-position, or DC V Type of control output 2: ON/OFF, PWM, 3-position, or DC 0 10 V Type of inputs: e.g. external room temperature sensor, changeover sensor, keycard contact etc. Type of thermostat: stand-alone, stand-alone with 7-day timer, or communicating thermostat Thermostat design: wall- or semi flush-mounted Other important requirements Description of RDG range The RDG is a compact, wall-mounted version with an elegant and modern design. The product consists of 2 lines of versatile products RDG100 and RDG400: RDG100 line for FCUs plus universal (e.g. chilled ceilings or radiators) and heat pump applications RDG400 line for VAV applications The thermostats are available as stand-alone versions, stand-alone with 7-day program and KNX versions tailored for use with Synco 700 via LTE-mode, for integration in Synco living or BACS (Building Automation and Control System) via S-mode. Product range RDG RDG100 the versatile stand-alone thermostat with ON/OFF and modulating (PWM or 3-position) outputs RDG100T the versatile stand-alone thermostat with 7-day program and same functionality as RDG100, plus infrared receiver for remote control RDG100T/H the versatile stand-alone thermostat is the landscape version of RDG100T, the 7-day program can be disabled RDG100KN the versatile communicating thermostat with the same functionality as RDG100, plus KNX interface RDG110 the robust stand-alone thermostat with relay outputs (SPDT) for applications with max. 5 A current on the control outputs. This thermostat is the ideal solution for ON/OFF applications with electric heater, heat pumps, or heat pumps with reversing valve (RV). RDG140 the modulating thermostat operating on AC 24 V (SELV) with DC 0 10 V control outputs 4
5 RDG160 the energy-efficient modulating thermostat to control electronic commutated fan motors (ECM Fans), operating on AC 24 V (SELV) with DC V outputs for valve and fan RDG160KN the communicating energy-efficient modulating thermostat for controlling electronic commutated fan motors (EC Fans) and either DC or 2-position valves, or for 3-speed fan and DC valves, including KNX interface RDG400 the versatile stand-alone thermostat for VAV applications with modulating and ON/OFF outputs RDG400KN the versatile communicating thermostat with the same functionality as RDG400, plus KNX interface A number of control parameters can be adjusted on each thermostat to optimize the control performance. Description of RDF semi flush-mount range The RDF.. range is a compact semi flush mount solution. The RDF6.. line fits into round conduit boxes with a 60 mm diameter and a minimum 40 mm of depth. The RDF3.. and RDF4.. lines are designed to fit into conduit boxes with fixing center 60.3 mm (British standard BS4662). The RDF and RDU are two product ranges featuring versatile and slim products: RDF range for FCUs and heat pump applications RDU range for VAV applications The thermostats are available as stand-alone, stand-alone with 7-day program and KNX versions tailored for use with Synco 700 via LTE-mode, for Synco living or for integration in BACS via S-mode. There is also a version available with ModBus interface. Product range RDF/RDU stand-alone RDF300 the versatile stand-alone thermostat with ON/OFF or modulating 3-position outputs RDF also includes backlit display RDF340 modulating thermostat operating on AC 24 V (SELV) with DC 0 10 V control outputs RDF310.2 basic stand-alone thermostat for 2-pipe applications RDF also offers a backlit display and infrared receiver for remote control RDF600 versatile stand-alone thermostat for use with round conduit boxes conforming to CEE/VDE with the same functionality as RDF RDU340 the versatile stand-alone thermostat for VAV applications with modulating DC 0 10 V and ON/OFF outputs RDF product range, stand-alone with time program RDF600T the versatile stand-alone thermostat with 7-day program and same functionality as RDF600, plus infrared receiver for remote control and backlit digital display for use with round conduit boxes conforming to CEE/VDE RDF basic stand-alone thermostat for 2-pipe applications, with 7-day program, backlit digital display and infrared receiver for remote control Product range RDF/RDU with bus interface RDF301 communicating thermostat with the same functionality as RDF300, plus KNX interface and backlit display RDF communicating thermostat with the same functionality as RDF301, plus switching groups for lighting and blind control via KNX S-mode RDF600KN communicating thermostat for use with round conduit boxes conforming to CEE/VDE with the same functionality as RDF301 RDF302 communicating thermostat with the same functionality as RDF300, including ModBus interface RDU341 communicating thermostat with the same functionality as RDU340, plus KNX interface 5
6 Description of applications The RDG/RDF thermostats cover the following applications: FCUs via ON/OFF or modulating control outputs: 2-pipe system 2-pipe system with electric heater 2-pipe system and radiator/floor heating 1 4-pipe system 4-pipe system with electric heater 1 2-stage heating or cooling system 1 VAV systems via ON/OFF or modulating control outputs: Single-duct system Single-duct system with electric heater Single-duct system and radiator/floor heating 1 Single-duct system with heating/cooling coil 1 Chilled/heated ceilings (or radiators) via ON/OFF or modulating control outputs: Chilled/heated ceiling Chilled/heated ceiling with electric heater Chilled/heated ceiling and radiator/floor heating 1 Chilled/heated ceiling, 2-stage heating or cooling 1 6
7 Heat pumps with DX type equipment: 1-stage compressor for heating or cooling 1-stage compressor for heating or cooling with electric heater 1-stage compressor for heating or cooling and radiator/floor heating 1 1-stage compressor for heating and cooling with reversing valve 1 2-stage compressor for heating or cooling 1 The RDG/RDF offer extensive features and functions 2 Operating mode: Comfort, Economy and Protection Energy saving functions: external operating mode switchover, 7-day program, keycard or window contact, minimum and maximum setpoint limitation, etc. Numerous applications selectable via DIP switch Heating/cooling changeover: automatic or manual Control output signals: ON/OFF (triac or relay), PWM, 3-position and DC V Fan control: automatic or manual fan speed for 1-speed, 3-speed or ECM 3 fan Fan operation: fan enable, heating only, cooling only, fan disable Multifunctional inputs: (function selectable) External temperature sensor Heating/cooling changeover sensor or switch Operating mode switchover for keycard, window or time switch contact Electric heater release Dew point monitor Fault input 7-day program Timer for prolonged presence and absence function Button lock Backlit display Infrared remote control Reminder for cleaning fan filter Floor temperature limitation function Various parameters for setpoint adjustment and control setting KNX communication interface: Synco700 via LTE mode, Synco living and BACS (Building Automation and Control System) via S-mode Switching groups for lighting and blind control via KNX S-mode ModBus communication interface 1 Applications covered by RDG thermostats only 2 Feature availability depends on thermostat type 3 Electronic commutated motor, DC V 7
8 Application description Control sequences for heating and/or cooling, 1 or 2 stages Multifunctional inputs for keycard contact, external sensor, etc. Automatic or manual heating/cooling changeover Automatic or manual fan speed 3-speed, 1-speed and mod. (ECM) fan control (DC V) Fan operation selectable in heating and cooling mode (enable, disable, heating only or cooling only) Fan coil application overview Application Type of control outputs RDG.. Wall-mounted range RDF.. Semi flush-mounted range 2-pipe system 2-pipe (ON/OFF) RDG110 RDF300.. RDF310.. RDF600.. RDF pipe mod. (PWM) 2-pipe mod. (3-pos.) RDF300.. RDF pipe mod. (DC V) RDG140 RDG160KN RDF340 2-pipe mod. (DC V) ECM fan control (DC V) RDG pipe (ON/OFF) ECM fan control (DC V) RDG160KN 2-pipe system with el. heater 2-pipe (ON/OFF), with el. heater (ON/OFF) RDG110 RDF300.. RDF600.. YE B2 T 3076S02 2-pipe (ON/OFF), with el. heater (mod. PWM or 3-pos.) 2-pipe mod. (PWM), with el. heater (ON/OFF, PWM or 3-pos.) Y1 T (B1) 2-pipe mod. (3-pos.), with el. heater (ON/OFF, PWM or 3-pos.) 2-pipe mod. (DC V), with el. heater (DC V) RDG140 RDG160KN RDF340 M1 T (B1) 2-pipe mod. (ON/OFF, DC V), with el. heater (ON/OFF, DC V). ECM fan control (DC V) RDG
9 Application 2-pipe system and radiator heating Type of control outputs 2-pipe (ON/OFF) and radiator (ON/OFF) 2-pipe (ON/OFF) and radiator (mod. PWM or 3-pos.) 2-pipe mod. (PWM) and radiator (ON/OFF, PWM or 3-pos.) 2-pipe mod. (3-pos.) and radiator (ON/OFF, PWM or 3-pos.) RDG.. Wall-mounted range RDG110 RDF.. Semi flush-mounted range 2-pipe mod. (DC V) and radiator (DC V) RDG140 RDG160KN 2-pipe mod. (ON/OFF, DC V) and radiator (ON/OFF, DC V). ECM fan control (DC V) RDG pipe system 4-pipe (ON/OFF) RDG110 RDF300.. RDF pipe mod. (PWM) 4-pipe mod. (3-pos.) 4-pipe mod. (DC V) RDG140 RDG160KN RDF340 4-pipe mod. (ON/OFF, DC V). ECM fan control (DC V) RDG pipe system with el. heater 4-pipe (ON/OFF) with el. heater (ON/OFF) YE B2 3076S05 4-pipe (ON/OFF and 3-pos.) with el. heater (ON/OFF) 4-pipe mod. (PWM) with el. heater (ON/OFF) Y2 T (B1) 4-pipe mod. (PWM and 3-pos.) with el. heater (ON/OFF) Y1 M1 T (B1) 2-stage, heating or cooling 2-stage (ON/OFF) heating or cooling 2-stage mod. (PWM) heating or cooling 2-stage mod. (3-pos.) RDG110 2-stage mod. (DC V) RDG140 RDG160KN 2-stage mod. (ON/OFF, DC V). ECM fan control (ON/OFF, DC V) RDG160.. Abbreviations ON/OFF: 2-position control 3-pos.: Modulating 3-position control signal PWM: Pulse Width Modulation control signal DC V: Modulating DC V control signal ECM fan: Electronic Commutated Motor for fan, DC V el. heater: Electric heater mod. output: Modulating output 9
10 Fan coil product overview Communicating Product Application Stand-alone Stand-alone with 7-day program Communicating RDG100 Versatile thermostats with control output signal (ON/OFF) or mod. (PWM or 3-pos.) 2-pipe (ON/OFF, PWM or 3-pos.) 2-pipe with electric heater FCU: (ON/OFF, PWM or 3-pos.) el. heater: (ON/OFF, PWM or 3-pos.) 2-pipe and radiator FCU: (ON/OFF, PWM or 3-pos.) radiator: (ON/OFF, PWM or 3-pos.) 4-pipe (ON/OFF, PWM and/or 3-pos.) 4-pipe with electric heater FCU: (ON/OFF, PWM and ON/OFF, PWM or 3-pos.) el. heater: (ON/OFF) 2-stage heating or cooling FCU: (ON/OFF, PWM or 3-pos.) RDG100 RDG100T RDG100T/H RDG100KN (KNX) RDG110 Robust thermostat with relay outputs (SPDT) for ON/OFF control sequences 2-pipe (ON/OFF) 2-pipe (ON/OFF) with el. heater (ON/OFF) 2-pipe (ON/OFF) and radiator (ON/OFF) 4-pipe (ON/OFF) 2-stage (ON/OFF) heating or cooling RDG110 RDG140 Thermostat for mod. control sequences with (DC V) output signals 2-pipe (DC V) 2-pipe (DC V) with el. heater (DC V) 2-pipe (DC V) and radiator (DC V) 4-pipe heating (DC V) and cooling (DC V) 2-stage (DC V) heating or cooling RDG140 RDG160.. Thermostat for mod. control sequences with (DC V) output signals for valve and fan control (ECM) DC V 2-pipe (DC V) 2-pipe (DC V) with el. heater (DC V) 2-pipe (DC V) and radiator (DC V) 4-pipe heating (DC V) and cooling (DC 0 10 V) 2-stage (DC V) heating or cooling RDG160 RDG160KN (KNX) RDG160KN Communicating thermostat for mod. control sequences with DC V or ON/OFF output signals for valve and fan control DC V (ECM), 1- or 3-speed With ECM fan control (DC 0 10 V signal) 2-pipe (ON/OFF) 2-pipe (DC V) 2-pipe (ON/OFF) with el. heater (ON/OFF) 2-pipe (DC V) with el. heater (ON/OFF) 2-pipe (DC V) with el. heater (DC V) 2-pipe (ON/OFF) and radiator (ON/OFF) 2-pipe (DC V) and radiator (ON/OFF) 2-pipe (DC V) and radiator (DC V) 4-pipe heating (ON/OFF) and cooling (ON/OFF) 4-pipe heating (DC V) and cooling (DC 0 10 V) 2-stage (ON/OFF) heating or cooling 2-stage (DC V) heating or cooling RDG160KN (KNX) With 3- or 1-speed fan 2-pipe (DC V) 2-pipe (DC V) with el. heater (DC V) 2-pipe (DC V) and radiator (DC V) 4-pipe heating (DC V) and cooling (DC 0 10 V) 2-stage (DC V) heating or cooling 10
11 Product Application Stand-alone Semi flush-mounted units: RDF Stand-alone with 7-day program Communicating RDF300.. Versatile thermostats with relay ouputs: ON/OFF or 3-pos. 2-pipe FCU: (ON/OFF or 3-pos.) 2-pipe (ON/OFF) with el. heater (ON/OFF) 4-pipe (ON/OFF) RDF300.. RDF301.. (KNX) RDF302 (ModBus) RDF310../410..* 2-pipe (ON/OFF) RDF310.. RDF Basic thermostats for 2-pipe application RDF340 Thermostat for mod. control sequences with (DC V) output signals RDF600..* Thermostats for use with round conduit boxes conforming to CEE/VDE, with relay outputs: ON/OFF or 3-pos. 2-pipe (DC V) 2-pipe (DC V) with el. heater (DC V) 4-pipe heating (DC V) and cooling (DC V) 2-pipe FCU: (ON/OFF or 3-pos.) 2-pipe (ON/OFF) with el. heater (ON/OFF) 4-pipe (ON/OFF) RDF340 RDF600 RDF600T RDF600KN (KNX) *Variants RDF300 RDF RDF301 RDF RDF310.2 Basic version Thermostat with backlit display Thermostat with KNX interface Communicating thermostat with 4 buttons for lighting and blinds Basic version RDF RDF RDF600 RDF600T RDF600KN RDF302 Basic version with backlit display and infrared remote control Basic version with backlit display, 7-day program and infrared remote control Basic version for use with round conduit boxes Basic version with 7-day program Communicating thermostat with KNX interface Communicating thermostat with ModBus interface 11
12 Application description For heating and/or cooling applications with heated/chilled ceiling or radiator Control sequences for heating and/or cooling, 1- or 2-stages Dew point monitoring Multifunctional inputs for keycard contact, external sensor, etc. Automatic or manual heating/cooling changeover Universal application overview Chilled/heated ceiling or radiator Application Type of control outputs RDG Wall-mounted range Chilled/heated ceiling with changeover Chilled/heated ceiling (ON/OFF) RDG110 Chilled/heated ceiling, mod. (PWM) Chilled/heated ceiling, mod. (3-pos.) Chilled/heated ceiling, mod. (DC V) RDG140 RDG160.. Chilled/heated ceiling and el. heater Chilled/heated ceiling (ON/OFF) and el. heater (ON/OFF) Chilled/heated ceiling (ON/OFF) and el. heater (mod. PWM or 3-pos.) Chilled/heated ceiling, mod. (PWM) and el. heater (ON/OFF, PWM or 3-pos.) Chilled/heated ceiling, mod. (3-pos.) and el. heater (ON/OFF, PWM or 3-pos.) RDG110 Chilled/heated ceiling, mod. (ON/OFF, DC V) and el. heater (ON/OFF, DC V) RDG140 RDG
13 Application Chilled/heated ceiling and radiator Type of control outputs Chilled/heated ceiling (ON/OFF) and radiator (ON/OFF) Chilled/heated ceiling (ON/OFF) and radiator (mod. PWM or 3-pos.) Chilled/heated ceiling, mod. (PWM) and radiator (ON/OFF, PWM or 3-pos.) Chilled/heated ceiling, mod. (3-pos.) and radiator (ON/OFF, PWM or 3-pos.) Chilled/heated ceiling, mod. (ON/OFF, DC V) and radiator (ON/OFF, DC V) RDG Wall-mounted range RDG110 RDG140 RDG160.. Chilled ceiling and radiator Chilled ceiling (ON/OFF) and radiator (ON/OFF) Chilled ceiling (ON/OFF) and radiator (mod. PWM or 3-pos.) Chilled ceiling (PWM) and radiator (ON/OFF, PWM or 3-pos.) Chilled ceiling (3-pos.) and radiator (ON/OFF, PWM or 3-pos.) RDG110 Chilled ceiling (ON/OFF, DC V) and radiator (ON/OFF, DC V) RDG140 RDG160.. Chilled/heated ceiling with 2-stage cooling or 2-stage heating 2-stage (ON/OFF) heating or cooling RDG110 2-stage mod. (PWM) heating or cooling 2-stage mod. (3-pos.) heating or cooling 2-stage mod. (ON/OFF, DC V) heating or cooling RDG140 RDG160.. Abbreviations ON/OFF: 2-position control 3-pos.: Modulating 3-position control signal PWM: Pulse Width Modulation DC V: Modulating DC V control signal el. heater: Electric heater mod. output: Modulating output 13
14 Universal product overview Product Application Stand-alone Wall-mounted units: RDG Stand-alone with 7-day program Communicating RDG100 Versatile thermostats with control outputs signal ON/OFF or mod. (PWM or 3-pos.) RDG110 Thermostats with relay outputs (SPDT) for (ON/OFF) control sequences RDG140 Thermostat for mod. control sequences with (DC V) outputs signals Chilled/heated ceiling (ON/OFF, PWM or 3-pos.) Chilled/heated ceiling and el. heater CLC: (ON/OFF, PWM or 3-pos.) el.heater: (ON/OFF, PWM or 3-pos.) Chilled/heated ceiling and radiator CLC: (ON/OFF, PWM or 3-pos.) radiator: (ON/OFF, PWM or 3-pos.) Chilled ceiling and radiator CLC: (ON/OFF, PWM or 3-pos.) radiator: (ON/OFF, PWM or 3-pos.) Chilled/heated ceiling 2-stage CLC: (ON/OFF, PWM and/or 3-pos.) Chilled/heated ceiling (ON/OFF) Chilled/heated ceiling (ON/OFF) and el. heater (ON/OFF) Chilled/heated ceiling (ON/OFF) and radiator (ON/OFF) Chilled ceiling (ON/OFF) and radiator (ON/OFF) Chilled/heated ceiling 2-stage (ON/OFF) Chilled/heated ceiling (DC V) Chilled/heated ceiling (DC V) and el. heater (DC V) Chilled/heated ceiling (DC V) and radiator (DC V) Chilled ceiling (DC V) and radiator (DC V) Chilled/heated ceiling 2-stage (DC V) RDG100 RDG100T RDG100KN (KNX) RDG110 RDG140 RDG160.. Thermostat for mod. control sequences with (DC V) outputs signals Chilled/heated ceiling (DC V) Chilled/heated ceiling (DC V) and el. heater (DC V) Chilled/heated ceiling (DC V) and radiator (DC V) Chilled ceiling (DC V) and radiator (DC V) Chilled/heated ceiling, 2-stage (DC V) RDG160 RDG160KN (KNX) RDG160KN Communicating thermostat for mod. control sequences with DC V or ON/OFF output signals for valves 2-pipe (ON/OFF) 2-pipe (DC V) 2-pipe (ON/OFF) with el. heater (ON/OFF) 2-pipe (DC V) with el. heater (ON/OFF) 2-pipe (DC V) with el. heater (DC V) 2-pipe (ON/OFF) and radiator (ON/OFF) 2-pipe (DC V) and radiator (ON/OFF) 2-pipe (DC V) and radiator (DC V) 4-pipe heating (ON/OFF) and cooling (ON/OFF) 4-pipe heating (DC V) and cooling (DC 0 10 V) 2-stage (ON/OFF) heating or cooling 2-stage (DC V) heating or cooling RDG160KN (KNX) 14
15 Application description Control sequences for heating and/or cooling, 1- or 2-stage Dew point monitoring Multifunctional inputs for keycard, contact, external sensor, etc. Min. ON/OFF time for compressor short cycle protection Heat pumps application overview Application Type of control outputs RDG.. Wall-mounted range RDF.. Semi flush-mounted range Compressor in DX-type equipment for heating or cooling 1-stage compressor (ON/OFF) RDG110 RDG160KN RDF300.. RDF310.. RDF410.. RDF600.. Compressor in DX-type equipment for heating or cooling, with el. heater 1-stage compressor (ON/OFF), with el. heater (ON/OFF) RDG110 RDG160KN RDF300.. RDF
16 Application Type of control outputs RDG.. Wall-mounted range RDF.. Semi flush-mounted range Compressor in DX-type equipment heating and cooling 1-stage compressor (ON/OFF) for heating and cooling RDG110 RDG160KN RDF300.. RDF stage compressor (ON/OFF) for heating and cooling with reversing valve RDG110 Compressor in DX-type equipment, cooling or heating, 2-stage 2-stage compressor (ON/OFF) for heating or cooling RDG110 RDG160KN Abbreviation ON/OFF: 2-position control el. heater: Electric heater 16
17 Heat pumps product overview Product Application Stand-alone Wall-mounted units: RDG Stand-alone with 7-day program Communicating RDG110 Thermostat with relay output (SPDT) to ON/OFF control sequences RDF600..* Thermostats for use with round conduit boxes conforming to CEE/VDE, with relay outputs: ON/OFF Semi flush-mounted units: RDF RDF300../400..* Versatile thermostats with relay ouputs: ON/OFF 1-stage compressor (ON/OFF) for heating or cooling 1-stage compressor (ON/OFF), with el. heater (ON/OFF) 1-stage compressor (ON/OFF) for heating and cooling 1-stage compressor (ON/OFF) for heating and cooling with reversing valve 2-stage compressor (ON/OFF) for heating or cooling 1-stage compressor (ON/OFF) for heating or cooling 1-stage compressor (ON/OFF), with el. heater (ON/OFF) 1-stage compressor (ON/OFF) for heating and cooling 1-stage compressor (ON/OFF) for heating or cooling 1-stage compressor (ON/OFF), with el. heater (ON/OFF) 1-stage compressor (ON/OFF) for heating and cooling RDG110 RDF600 RDF600T RDF600KN (KNX) RDF300.. RDF stage compressor(on/off) for heating or cooling RDF310.. RDF410.. Basic thermostats for 1-stage compressor RDG160KN Communicating thermostat with relay output: ON/OFF 1-stage compressor (ON/OFF) for heating or cooling 1-stage compressor (ON/OFF), with el. heater (ON/OFF) 1-stage compressor (ON/OFF) for heating and cooling 2-stage compressor (ON/OFF) for heating or cooling RDG160KN (KNX) *Variants RDF300 RDF RDF310.2 RDF Basic version Thermostat with backlit display Basic version Basic thermostat with backlit display and Infrared remote control RDF RDF600 RDF600T RDF600KN Basic thermostat with backlit display, weekly time program and Infrared remote control Basic version Basic version with 7-day program Communicating thermostat with KNX interface 17
18 Application description Control sequences for heating and/or cooling Modulating control output DC 0 10 V or 3-pos. for VAV box/air flow controller Multifunctional inputs for keycard, contact, external sensor, etc. Automatic or manual heating/cooling changeover Adjustable minimum and maximum limitation of air flow signal (DC 0 10 V) Modulating PI control Output signal inversion as an option VAV application overview Application Type of control outputs RDG.. Wall-mounted range RDF.. Semi flush-mounted range Single duct Single duct (DC V) for VAV-box RDG400.. RDU34.. Single duct mod. (3-pos.) for VAV-box RDG400.. Single duct with el. heater 3076S17 Single duct (DC V) for VAV-box, with el. heater (ON/OFF) RDG400.. RDU34.. V YV M YE Single duct (DC V) for VAV-box, with el. heater (mod. PWM or 3-pos.) Single duct (3-pos.) for VAV-box, with el. heater (DC V) RDG400.. RDG400.. B1 T 18
19 Application Single duct with radiator Type of control outputs Single duct (DC V) for VAV-box with radiator (ON/OFF) Single duct (DC V) for VAV-box with radiator (mod. PWM or 3-pos.) Single duct (3-pos.) for VAV-box with radiator (DC V) RDG.. Wall-mounted range RDG400.. RDG400.. RDG400.. RDF.. Semi flush-mounted range Single duct with heating/cooling coil Single duct (DC V) for VAV-box, with heating/cooling coil (ON/OFF) Single duct (DC V) for VAV-box, with heating/cooling (mod. PWM or 3-pos.) Single duct (3-pos.) for VAV-box, with heating/cooling (DC V) RDG400.. RDG400.. RDG400.. Abbreviations VAV: Variable Air Volume system ON/OFF: 2-position control PWM: Pulse Width Modulation DC V: Modulating DC V control signal 3-pos.: Modulating 3-position control signal el. heater: Electric heater mod. output: Modulating output VAV product overview Product Application Stand-alone Stand-alone with 7-day program Communicating Wall-mounted units: RDG RDG400.. Versatile thermostats with control outputs signal DC V, ON/OFF, PWM or 3-pos. Single duct for VAV-box VAV: (DC 0 10 V or 3-pos.) Single duct for VAV-box with electric heater VAV: (DC 0 10 V) el. heater: (ON/OFF, PWM or 3-pos.) VAV: (3-pos.) el. heater: (DC 0 10 V) Single duct for VAV-box with radiator VAV: (DC 0 10 V) radiator: (ON/OFF, PWM or 3-pos.) VAV: (3-pos.) radiator: (DC 0 10 V) Single duct for VAV-box with heating/cooling coil VAV: (DC 0 10 V) coil: (ON/OFF, PWM or 3-pos.) VAV: (3-pos.) heating/cooling coil: (DC 0 10 V) RDG400 RDG400KN (KNX) Semi flush-mounted units: RDU RDU34.. Thermostats for mod. control sequences with DC V and ON/OFF outputs signals Single duct (DC V) for VAV-box Single duct (DC V) for VAV-box with el. heater (ON/OFF) RDU340 RDU341 (KNX) 19
20 How to prepare and set up your room thermostats Introduction The versatile RDG and RDF room thermostats help you to better meet your customer s needs. The following information supports you in setting up your RDG and RDF thermostats. Control parameters A number of control parameters can be adjusted to optimize control performance and enable additional functions, making it possible to employ. The RDG and RDF thermostats in almost any type of application. The control parameters are assigned to 2 levels: Service level and Expert level The service level contains a small set of parameters to set up the thermostat for HVAC systems (control sequence) and to adjust the user interface. The expert level contains control parameters for fan, control inputs/outputs and other functions. Take care when changing parameters on the expert level as these changes impact the thermostat s control performance and functionality. TIP As a rule, you don t need to adjust parameters once the required application is selected via the DIP switch since the thermostat works correctly using factory set parameters. It may be nevertheless necessary, in some cases, to adjust application specific parameters. Control sequence (P01): select heating/cooling sequence and changeover function Multifunctional inputs (P38 P42): select the input functionality for X1, X2 and D1 Control outputs (P46 P47): select type of output signal (ON/OFF, PWM, 3-pos.) Fan function (P52...P62): select fan functionality TIP Installation and set up 1. Select a suitable thermostat. 2. Set application via DIP switch as per mounting instructions. 3. Wire and install the thermostat. Apply power. 4. Set parameter P01 (control sequence) and other application-specific parameters as needed. Note: ARG71 conduit box suitable for RDF3.. and RDF4.. semi flush-mount thermostats is available as an accessory item. 20
21 Control sequence (P01) Application-specific parameter This parameter is used to set the required heating and/or cooling sequence and to select automatic/manual changeover. Parameter P01 is preset as follow, depending on the selected application: 2-pipe or single-duct application: P01: = 1 = cooling only 4-pipe application: P01: = 4 = heating and cooling Sequence Mode Heating only Cooling only Manually select heating or cooling mode Automatic heating/cooling changeover Heating and cooling mode Parameter P01=0 P01=1 P01=2 P01=3 P01=4 Multifunctional inputs (X1, X2, D1) An NTC sensor of type NTC such as QAH11.1 (AI) or a switch (DI) can be connected to the input terminals. Input functionality can be freely configured. The factory settings are as follows: RDG range RDF range P38: Multifunctional input X1 External temperature sensor (1) Operating mode switchover (3) P40: Multifunctional input X2 Heating/cooling changeover (2) Heating/cooling changeover (2) P42: Multifunctional input D1 Operating mode switchover (3) N/A Available function on X1, X2 and D1 1 Function of inputs External/return air temperature (AI) (not available for input D1) Description Temperature sensor input for External room temperature Return air temperature Floor temperature sensor to limit the heating output 2 Heating/cooling changeover (AI/DI) Automatic heating/cooling changeover sensor or switch 3 Operating mode switchover (DI) Digital input to switch the operating mode to Economy 4 Dew point monitor (DI) Digital input for a dew point sensor to monitor condensation 5 Enable electric heater (DI) Digital input to enable/disable the electric heater via remote control 6 Fault (DI) Digital input to signal a fault on the display (e.g. dirty air filter) 7 Monitoring input (digital) 8 Monitoring input (temperature) Digital input to monitor the state of an external switch via bus (only for communicating variants) Sensor input to monitor the state of an external sensor (e.g. QAH11.1) via bus (only for communicating variants) Control outputs (P46 P47) The offers two control outputs, each of either type On/Off, PWM or 3-position. To select the required type, use the DIP switch and P46 (1st control output) and/or P47 (2nd control output). The RDG400.. for VAV applications offers two control outputs, DC 0 10 V and either ON/OFF, PWM or 3-position. To select the required type use the DIP switch and P46 (reheater/cooler control output) and/or P47 (damper actuator, DC V or 3-pos.). 21
22 Fan function (P03, P52...P62, P67): RDG and RDF offer an extensive fan control concept with a wide choice of functions and features. The required options can be selected via the control parameters: Fan mode automatic-manual or manual only (P03) Fan active in cooling mode only, active in heating mode only, disable (P52) Control output for 3-speed/1-speed fan (P53) Control output for ECM fan, DC V signal (P55 P57) on RDG160.. Fan minimum on time (P59) Operation in dead zone for conjunction with return air sensor or to avoid damage due to moisture (P60, P61) Fan start kick from standstill to overcome inertia and friction (P58) Fan overrun to avoid overtemperatures after the electric heater turned off (P54) Fan start delay by ON/OFF control to avoid cold or warm air (P67) Note: Fan operation must be disabled via control parameter (P52) for universal application. Parameters on communi cating thermostats On communicating thermostats, control parameters can be downloaded via ACS and ETS Service Tools. Note: RDG/RDF require an external KNX bus power supply if connected via OCI700. Diagnostic parameters TIP After installing and setting up the thermostat, you can check your configuration by going to the Expert level and selecting the diagnostic parameters dxx (d01, d02, etc.). Communicating, KNX thermostats In connection with Synco 700, the communicating, KNX thermostats operate in LTE-mode. The units are tailored as well for use with Synco living or for integration in BACS via S-mode. Refer to technical documentation CE1N3127 for detailed information on installing and commissioning a KNX system. TIP Suggestions for saving energy Use thermostats with 7-day program Use thermostats with modulating control outputs (e.g. DC V or 3-position) Use thermostats with ECM fan control (DC V) Use KNX communicating thermostats Activate auto fan function Connect external operating mode switchover for central operating mode control Connect window contacts to avoid energy losses when windows are open Connect keycard contact for switching the unit to Economy mode when rooms are not occupied Define optimum setpoint limitations (heating max. 20 C, cooling min. 25 C) to minimize energy usage In application with electric heater, use function Electric heater enable (P38, P40...) Inform enduser of prolonged absences and presence function 22
23 FAQ Where are the DIP switches located? On RDG, the DIP switches are located at the rear of the unit; on RDF semi flush-mount thermostats, they are located on the inner side of the front panel. Where do I find the correct DIP switch position? Refer to the Mounting Instructions and on the product. How can I set the parameters? The procedure for setting the parameters (service or expert level) is described in the basic documentation of the thermostats. When do I have to set the control parameters? You generally do not need to adjust parameters since the unit works correctly using the factory-set parameters. Nevertheless, in some rare cases, you may need to adjust the application-specific parameters during commissioning to enable desired functions. For that, access the expert level. Refer to technical documentation for detailed information. The control parameters on the service level for HVAC systems and for adjusting the user interface can be accessed at any time. Is it possible to reload the default timer setting? Yes. The default timer setting (A1 A8) and the procedure for reloading are described in the technical documentation. Is it possible to reset the control parameters? Yes. The factory-set control parameters can be reloaded via parameter P71 by changing the value to ON and by confirming with the buttons. Refer to technical documentation for detailed information. Can the current settings and installation be checked? On the expert level, some diagnostic parameters (d01, d02, etc.) are available for checking the selected application, the status of the inputs and for testing the 3-position outputs. Refer to technical documentation for detailed information. Reference to the basic documentation P3076: RDF3../6.. stand-alone thermostats for FCUs P3171: RDF3../6.. KNX communicating thermostats for FCUs P3181: RDG1.. stand-alone thermostats for FCUs P3191: RDG1..KN KNX communicating thermostats for FCUs P3182: RDG400 stand-alone thermostat for VAV P3192: RDG400KN KNX communicating thermostats for VAV P3078: RDU340 stand-alone thermostat for VAV P3172: RDU341 KNX communicating thermostat for VAV P3079: RDF302 ModBus communicating thermostat for FCUs 23
24 Application examples Installation and set up 1. Select a suitable thermostat. 2. Set application via DIP switch according to the mounting Instructions. 3. Wire and install the thermostat. Apply power. 4. If necessary, set parameter P01 (control sequence) and other application-specific parameters. Fan coil application examples Application Fan coil unit, 2-pipe cooling only How to set the application Valve actuator: ON/OFF Keycard contact 1. Thermostat: RDG DIP switch: 2-pipe application Y1 = ON/OFF 3. Wiring: Actuator Y1-N Fan Q1...Q3-N Key card D1-GND 4. Parameters: no change necessary (factory-setting) TIPS Keycard contact in hotel guest rooms helps saving energy costs RDG100T with 7-day program RDG100KN communicating KNX Fan coil unit, 2-pipe with el. heater Valve actuator: ON/OFF Heating with electric heater ON/OFF Automatic changeover Return air temperature sensor 1. Thermostat: RDG DIP switch: 2-pipe application, el. heater 3. Wiring: Actuator Y11-N El. heater Y21-N Fan Q1...Q3-N Temp. sensor X1-M H/C changeover sensor X2-M 4. Parameters: P01 = 3 (automatic H/C changeover) TIPS RDG110 with relay outputs can drive direct an el. heater up to 1 kw Fan coil, 4-pipe with el. heater Valve actuators H&C: PWM Electric heater: ON/OFF Electric heater enable input Window contact 1. Thermostat: RDG DIP switch: 4-pipe application, el. heater Y1 = PWM Y3 = PWM 3. Wiring: Actuator heating Y1-N Actuator cooling Y3-N Contactor 1 for el. heater Y2-N Fan Q1...Q3-N El. heater enable X1-M Window cont. D1-GND 4. Parameters: P38 = 5 (El. heater Input) P46 = 2 (PWM heating) P47 = 2 (PWM cooling) TIPS Electric heater enable signal for saving energy costs Note 1 : Add relay if load exceeds 1A! 24
25 Application How to set the application FCU, 2-pipe and floor heating, single speed 2-pipe, cooling only: ON/OFF Floor heating limitation (ON/OFF) with temperature limitation Single speed fan 1. Thermostat: RDG DIP switch: 2-pipe application and radiator Y1 = ON/OFF Y3 = ON/OFF 3. Wiring: Actuator cooling Y1-N Actuator heating à Y3-N Fan Q1-N Floor temperature sensor X1-M 4. Parameters: P51 = 25 C (floor Heat. Temp. limit) P53 = 1 (single speed fan) TIPS Limited heat supply to the floor to avoid overheating (DIN EN 1264) thus protecting the floor and ensuring more comfort Select 2-pipe and el. heater for application with electric floor heating FCU, 2-pipe with electric heater, ECM fans, thermostat with KNX L N KNX CE+ CE- L -Q2 Y50 Y10 1. Thermostat: RDG160KN 2. DIP switch: 2-pipe application, el. heater Y10 = DC 0 10 V Q2 = ON/OFF 3. Wiring: Actuator Y10-Go El. heater Q2-N ECM fan Y50-Go 4. Parameters: No changes necessary (factory-setting) Valve actuators (DC V) Electric heater ON/OFF (relay) ECM fan (DC signal) TIPS Modulating (ECM) fan control for optimal comfort, lower level of noise and energy costs saving Check ECM fan max. (P55) and min. (P56) Universal application example Chilled ceiling and radiator Chilled ceiling (3-pos.) and radiator (PWM) Dew point monitor 1. Thermostat: RDG DIP switch: 2-pipe application and radiator Y1/Y2 = 3-pos. Y3 = PWM 3. Wiring: Actuator cooling Y1/Y2-N Actuator heating Y3-N Dew point monitor X1-M 4. Parameters: P38 = 4 (dew point input) P46 = 2 (PWM) P52 = 0 (fan disable) TIP Dew point monitoring to detect condensation. Cooling is stopped if condensation occurs. 25
26 VAV application examples Application VAV single duct, cooling only How to set the application Damper actuator: 0 10 V Window contact 1. Thermostat: RDG DIP switch: Single duct application Y10 = DC V 3. Wiring: Actuator Y10-Go-G Window contact D1-GND 4. Parameters: no change (= default) TIP Window contact for saving energy during the airing of rooms VAV single duct and el. reheater Damper actuator: 3-pos. El. heater: DC V Central time switch 1. Thermostat: RDG DIP switch: Single duct application, el. heater Y10 = DC V 3. Wiring: Actuator Y1/Y2-G El. heater Y10-Go Time switch D1-GND 4. Parameters: P47 = 1 (VAV output 3-pos.) TIPS Use a central time switch (e.g. SEH62.1) to set back room temperature during non-business hours Adjust parameter Prolong comfort period (P68) to allow occupant to override the central time switch, e.g. when working overtime Heat pump application example Compressor with reversing valve 1. Thermostat: RDG DIP switch: 4-pipe application 3. Wiring: Compressor Y11/Y21-N Reversing valve Y12/Y22-N 4. Parameters: P52 = 0 (fan disable) Set control sequence to manual changeover (P01=2); then the user can select manually between heating and cooling Compressor: ON/OFF Reversing valve: ON/OFF 26
27 Notes 27
28 Siemens Switzerland Ltd Infrastructure & Cities Sector Building Technologies Division International Headquarters Gubelstrasse Zug Switzerland Tel Siemens Building Technologies Infrastructure & Cities Sector Brunel House Sir William Siemens Square, Frimley Camberley Surrey, GU16 8QD United Kingdom Tel Siemens Ltd Infrastructure & Cities Sector Building Technologies Division 22/F, AIA Kowloon Tower, Landmark East 100 How Ming Street Kwun Tong, Hong Kong Tel The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. Siemens Switzerland Ltd, 2013 Order no en 0,71306 Answers for infrastructure. Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming and resource shortages. Maximum efficiency has top priority and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. We are the trusted technology partner for energy-efficient, safe and secure buildings and infrastructure.
Room thermostats wide variety and high energy efficiency
Room thermostats wide variety and high energy efficiency New room thermostats of modern design for fan coil units and universal applications Answers for infrastructure. Room thermostats energy-efficient
Flush-mounted room thermostats
s 3 076 RDF300, RDF300.02, RDF340 RDF400.01 RDF600 RDF600 Flush-mounted room thermostats for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment RDF300
More efficiency in office buildings with HVAC, lighting and security
The worldwide standard for home and building control More efficiency in office buildings with HVAC, lighting and security Simply more productive: Higher energy efficiency and more flexibility thanks to
KNX for building and room automation simple and efficient
The worldwide standard for home and building control KNX for building and room automation simple and efficient Save energy and effort with a comprehensive portfolio for electrical and HVAC applications.
More efficiency in hotels with HVAC, lighting and security
The worldwide standard for home and building control More efficiency in hotels with HVAC, lighting and security Simply comfortable: Higher energy efficiency and more flexibility thanks to Synco HVAC controllers
Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems
s 3 72 Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems RDU34 KNX bus communications (S-mode and LTE mode) Backlit display PI / P control Outputs for DC 0 0
More efficiency in schools with HVAC, lighting and security
The worldwide standard for home and building management More efficiency in schools with HVAC, lighting and security Simply first class: Higher energy efficiency and more flexibility thanks to Synco HVAC
Building Technologies
Building Technologies RXB room automation system System overview Contents Comfort and well-being in every room...5 Range overview...6 Coordinated room controllers...7 The room units: the key to individual
Energy efficiency in building automation and control
Energy efficiency in building automation and control Proven applications for heating and cooling supply Answers for infrastructure. Efficient VAC control protects the environment and increases comfort
Efficient building technology for retirement and nursing homes
The worldwide standard for home and building control Efficient building technology for retirement and nursing homes Simply safe: Higher energy efficiency and more flexibility thanks to Synco HVAC controllers
Answers for infrastructure. HVAC control with Synco simple and energy-efficient
Answers for infrastructure. HVAC control with Synco simple and energy-efficient Synco for enhanced comfort and energy efficiency Buildings place different requirements on HVAC control systems depending
Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output
Heating with LHW and cooling with CHW changeover Modulating control of heating and cooling valve (2 pipe) on analog Automatic or manual 3-speed fan control Room temperature and fan speed operation via
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
Highly flexible the right KNX/DALI gateway for every requirement
The worldwide standard for home and building control Highly flexible the right / gateway for every requirement Integrating lighting control into building control safely, efficiently and comfortably with
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-23 09 93 (November 2015) ----------------------------- Preparing Activity: USACE Superseding UFGS-23 09 23 (May 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
Inwall Room Temperature Unit
Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall
HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function
Specifications Supply Voltage 240VAC @ 0.07Amps or 24VAC @ 0.380Amps Relays 240V @ 12A max (resistive) / Comp1,2,3, Aux Ht, Rv O/B) Fuses (Equipment) 15 Amps Maximum 3AG Control Range Minus 10 to 50C Control
RRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats
Communicating Thermostats Add More Flexibility to Building Automation with New Communicating Thermostats More Choices. More Possibilities. From zone control to rooftop units and nearly everything in between,
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Building Technologies. Thermostats and room controllers. General Product range overview Thermostats
9 Building Technologies Thermostats and room controllers General Product range overview Thermostats General Thermostats overview The thermostat range of Siemens includes products for individual room control,
CR24-.. Single room controllers
Product information CR4- CR4- Single room controllers Table of contents wwwbelimocom Overview of the system Overview of functions 3 Technical data sheets CR4-B1 / CR4-A1 Single room controllers CR4-B /
CRK24-B1 Heated/chilled ceiling system
CRK4-B1 CRK4-B1 Heated/chilled ceiling system Table of contents Principle 3 Night switch-off: Regulating the 6-way valve with Energy Hold Off (EHO) 4 All options: 6-way valve regulation with pre-comfort,
OpenAir robust damper actuators for energy-efficient ventilation
OpenAir robust damper actuators for energy-efficient ventilation Durable actuators for HVAC applications, air volume control as well as fire and smoke protection dampers Answers for infrastructure and
Controls for fan coil units and cassettes
Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11
LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.
LMS The modular management system for condensing boilers Control Products & Systems OEM Answers for infrastructure. LMS advanced electronics and proven software At times of dwindling resources, rising
T5000 T000 LCD Digital Fan Coil Thermostat
T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,
Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
RVL470. Heating Controller. Building Technologies HVAC Products. Series B
2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
Designer. of control solutions NA O7.124A
u n i v e r s a l c o m f o r t Designer of control solutions NA O7.124A CONTROL ADAPTED TO THE ENTIRE RANGE V for Vision: Our range of CIAT controls features all the techniques used for air conditioning,
Answers for infrastructure. HVAC building technology quality and energy effi ciency from strong partners
Answers for infrastructure. HVAC building technology quality and energy effi ciency from strong partners HVAC building technology energy savings and assured comfort from experienced partners HVAC systems
On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range
Electromechanical controls Air control Water control On/off room thermostats range On/off room thermostats range Electronic controls Air control On/off V30 range On/off V30 range Water control Master/slave
What s the Difference? 2 Pipe vs 4 Pipe Fan Coil
Head Office Neptronic 400 Lebeau Blvd. Montreal, Quebec, Canada H4N R6 Tel.: (54) -4 Fax: (54) -6 Toll Free: -800-6-08 What s the Difference? Pipe vs 4 Pipe Coil There are many questions that arise when
PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
Variable Air Volume - VAV
Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:
Heating Controller. Building Technologies HVAC Products
2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or
AIR COOLED CHILLER CHILLED WATER PUMP CONTROL: The chilled water pump with the lowest runtime will automatically start when the outside air temperature rises above the system enable setpoint. When the
ABB i-bus KNX Fan Coil Controller FC/S 1.1
Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
T-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
Desigo building automation flexible and energy-efficient
Desigo building automation flexible and energy-efficient The intelligent system for all building types, sizes and all applications Answers for infrastructure. Desigo high energy efficiency and flexibility
Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted 756627xx, 756637xx, 756657xx
756627xx, 756637xx, 756657xx Documentation Product name: Push button 2-, 3-, 5- gang RTR + display Design: UP (flush-mounting type) ETS search path: Push button / Push button xgang / Push button xgang
CoolTeg Plus Chilled Water (CW) version: AC-TCW
version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420
Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
Single Zone LCD Thermostat Operating Instructions
Fan Cool Furnace *Heat Pump or Heat Strip On/Off F Single Zone LCD Thermostat Operating Instructions MODEL 3313192.XXX Cool/Furnace 3313193.XXX Cool/Furnace/Heat Pump 3313194.XXX Cool/Furnace/Heat Strip
SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
FX07 Field Controller
Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,
RZAHUC program version 1.1 Regulation for Reznor Air Handling Units
INSTALLATION INSTRUCTIONS OPTION 1xxx 1104_1000_EN Comfort Regulation (Carel pco) Detailed instructions RZAHUC program version 1.1 Regulation for Reznor Air Handling Units INDEX 1. Introduction... 4 1.1.
Product and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues
Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,
DUCTED AIR CONDITIONING SOLUTIONS
DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE
T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ
TSQ--0 7-7-07 T Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T SQ Model Configuration T SQ- Heating / Cooling Border Type (Lay-In) Full Face Nominal Round Duct Size
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch
Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com
Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3
EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3 English Table of Contents Table of Contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview:
Fundamentals of HVAC Control Systems
ASHRAE Hong Kong Chapter Technical Workshop Fundamentals of HVAC Control Systems 18, 19, 25, 26 April 2007 2007 ASHRAE Hong Kong Chapter Slide 1 Chapter 5 Control Diagrams and Sequences 2007 ASHRAE Hong
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
HVAC and Lighting Control Products for Open Building Automation Systems
HVAC and Lighting Control Products for Open Building Automation Systems Distech Controls offers an extensive line of feature-rich and cost effective controllers for building automation, covering HVAC
KONRAD. Hybrid Fancoil Series
KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks
Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.
EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...
HVAC central apartment unit with consumption data acquisition
s 2 741 Synco living HVAC central apartment unit with consumption data acquisition Series A QAX903 Heating and cooling control management for an apartment including precontrol for 2 room groups Ventilation
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX
Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Content Heating / Ventilation / Air Conditioning 3 The Right Room Climate 4 Optimised Energy Efficiency and well-being Room
Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3
TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System
TICS - Total Integrated Control Strategy Mid Range System Underfloor Heating & Cooling Control Solutions Energy efficient Heating and cooling TICS - Mid Range System Mid Range System TICS Mid Range Install
Thermostat with display
H/LN4691-0 674 59-64170 Thermostat with display RA00118AA_I-01PC-13W39 www.homesystems-legrandgroup.com Thermostat with display Contents Thermostat with display 1 Introduction 4 1.1 Warnings and recommendations
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL
INSTALLATION AND OPERATION MANUAL
RCS MODEL ZC4 4 ZONE HVAC INSTALLATION AND OPERATION MANUAL DCN: 141-0020-02 /0/03 INTRODUCTION The 4 Zone HVAC Controller series allows up to 4 standard electronic thermostats to independently control
Temperature controller for heated/chilled ceiling systems
Product information Temperature controller for heated/chilled ceiling systems Table of contents Overview of the system 2 Brief description, Accessories 3 Technical data sheet Technical data 5 Safety notes
Lesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
HEATING, VENTILATION & AIR CONDITIONING
HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating
for Plans Examiners and Building Inspectors
Building Technologies Program HVAC Controls Guide for Plans Examiners and Building Inspectors September 2011 Authors: Eric Makela, PNNL James Russell, PECI Sarah Fujita, PECI Cindy Strecker, PECI Prepared
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy
LG Air conditioning Company Multi V Water Ⅱ Air Conditioning Academy 1.1 What is Multi V Water II? High Performance Prospect rights Water pipe Refrigerant pipe Indoor unit Beautiful Exterior Convenience
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
Smile. The All-In-One Heating Controller
Smile EVERYTHING UNDER CONTROL The All-In-One Heating Controller Versatile, energy-efficient heating control. The All-In-One Heating Controller Smile controllers are ideal to gain maximum efficiency from
HEAT HEAT COOL HEAT PUMP COOL
OWNER S MANUAL RESIDENTIAL THERMOSTAT P/N P374-1800 HEAT COOL HEAT PUMP Su AUTO 0I20: Pm 74 COOL HEAT 27 7-DAY MABLE DIGITAL THERMOSTAT 3 Configurable Outputs Accepts Optional Humidity Module: Control
DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.
1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring
OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1
--- OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM Serial number: Year: Please quote this number when contacting customer service!
Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.
Install Guide CT100 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T
Heating Actuators in the MIX2 Series HMG 6 T, HME 6 T and FIX2 HM 12 T HMG 6 T 4930240 HME 6 T 4930245 HM 12 T 4940245 Updated: Dec-14 (subject to change) Page 1 of 61 Contents 1 Contents 2 FUNCTIONAL
T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control
T Series arge CD Digital Thermostat 0/0 VAC -pipe/-pipe fan coil control Data sheet Application T digital thermostats are designed for application of -speed fan and s in fan coil system. Including: -pipe
T6580 FAN COIL CONTROLLER
T6580 FN COIL CONTROLLER PRODUCT SPECIFICTION SHEET DESCRIPTION pleasing and modern appearance makes the T6580 ideal for living quarter applications, in particular offices and hotels. In all versions,
Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries. www.lonix.com
Guest Room Controls & Monitoring System Integrated Solution for Hotels Southern Countries www.lonix.com GUEST ROOM CONTROLS & MONITORING SYSTEM INDEX 1 GENERAL... 3 1.1 SYSTEM INTEGRATION... 3 1.2 USER
Heating and Cooling Basics Thermostat Control
Heating and Cooling Basics Thermostat Control UNI-LINE PRODUCT KNOWLEDGE 2012 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
The ABB i-bus KNX Room Master Concept Your first step into the KNX world
The ABB i-bus KNX Room Master Concept Your first step into the KNX world The Room Master Concept 1 New Step 1,000 New Options You specialize in installing electrical systems. With the ABB Room Master,
Controller for temperature control - EKC 102 REFRIGERATION AND AIR CONDITIONING. Manual
Controller for temperature control - EKC 102 REFRIGERATION AND AIR CONDITIONING Manual Introduction Application The controller is used for temperature control refrigeration appliances and cold room Defrost
Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A
COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850
Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.
English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation... 3 3.2 The user interface