General Specifications



Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

Company Profile Osaki, Shinagawa-ku, Tokyo, Japan Tel


General Specifications

Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface

General Specifications

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

General Specifications

Cable Pinouts. SRP I/O Module

Directory chapter 04

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Fieldbus slave modules with I/Os, DIO

General Specifications

Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science Microprocessor Project Laboratory

Technical Information

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

FarSync T2Ue. A 2 port PCI Express synchronous communications adapter

USB-ISO - USB 2.0 compliant, 1000VDC USB Full Speed isolator Users Manual

1701/22 FieldMonitor Management Interface Module

HDCATS-100. Installation Guide

RS-232 COMMUNICATIONS

DVI to Analog Converter

E-series/E1000-series Cable Guide

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

EUROMAP Protocol for Communication with Peripheral Equipment. General Description

Introduction. Features. Industrial 2 ports RS-422/485 with Surge PCI-Express Low Profile Serial Card

Cabling Specifications

1 Port FTDI USB to RS232 Null Modem Adapter

Evaluation Board. i-modul and Socket. Manual

Anderson Power Products

StructureScan HD Module. Installation Guide ENGLISH

maxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number Positioning Controller

Serial/ Parallel Combo PCi Card user manual

Serial Cables & Adapters

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

PCMCIA 1 Port RS EDITION OCTOBER 1999

DCS Input/Output Relay Card Series

INSTALLATION INSTRUCTIONS 160-Pin Cable for the NI PXI-2530B

5 Printing Reports and Labels

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

VS-0202 VS User Manual

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

Rack mounted telephone- and leased line modem for industrial applications

24V DRIVE INTERFACE BOARD (SERIAL) FTP-622DSL001/011/012/112

Safety Precautions WARNINGS

Technical Information

Foxboro Evo Process Automation System

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

IBS IP I/O Gateway. Data Sheet INTERBUS-S. Coupling Module for Two InterBus-S Lines

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Technical Details and Schematic: A 1200-Baud APRS / Packet Digipeater

DOCUMENTATION PD16 CP3-SVE-M75DC-24

ENGINEERING COMMITTEE

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Telephone- and leased line modem for industrial applications TD-36

The Clavinova-Computer Connection

Cable Specifications. T3 Trunk Cabling APPENDIX

Contents. SPECIFICATIONS AND FEATURES GUIDE NI Serial Hardware

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Future Technology Devices International Ltd. USB NMC-2.5m. USB to USB Null Modem Cable. Datasheet

SYSTEM DESCRIPTION Termination Boards

User Manual Revision English

Professional USB to Serial Adapter Hub with COM Retention

HDMI over Cat5 Video Extender with RS232 and IR Control

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

DT105X / PB105 Series

Inductive sensor NI10-M18-Y1X-H1141

Manual. Simrad StructureScan LSS-1 Sonar Module. English

MOTION COORDINATOR MC206X Quick Connection Guide

User Manual IC-485AI

Gold Solo Whistle Cable Kit

Serial ATA Hard Drive Docking Station

AMP/WALDOM MOLEX SOLDERLESS AMP/WALDOM

Elo Interactive Digital Signage (IDS): Remote Management

Evolving your plant with Field Digital Solutions

High Power Connectors for Power Supply and Power Circuits

D. PARAMETER SPECIFICATION Measured Variable: Displacement

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Manual Serial PCI Cards

IEC Connectors. Introduction

Publication Rev. C SIEMENS. (S5 Communications) Reference

Gold Eagle HV Gold Eagle HV Cable Kit (EtherCAT and CAN)

400 Series - Mini USB Buccaneer

1-Port R422/485 Serial PCIe Card

MACTek Corporation. USB HART Interface. Users Manual

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Transcription:

General Specifications Cables (for RIO) GENERAL This General Specification (GS) covers the specifications of signal cables and communication cables used in the RIO device. EXTERNAL DIMENSIONS, MODELS AND SUFFIX CODES Bus Cables and Terminators YCB121 RIO Bus Cable Shield Cable length F11E.ai YCB121 RIO Bus Cable Suffix Code -M Enter Cable length in every 1 m. Max. cable length 750 m (Suffix code: -M750). Option Code /NL Supports CSA Non-Incendive instrumentation YCB128 RIO Bus Terminator 18 28 RIO bus connector unit Terminator 20 F12E.ai YCB128 RIO Bus Terminator Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 Copyright May 2008 (YK) 1st Edition May 1, 2008 (YK)

2 Cables AKB301 Signal Cable (36-40 pins) 44.4 80 44.4 42 Cable length 32 F13E.ai AKB301 Signal Cable (36-40 pins) Suffix Code -M Enter Cable length in every 5 m. Max. cable length 50 m (Suffix code: -M050). AKB311 Signal Cable (6-10 pins) SPBD side F14E.ai AKB311 Signal Cable (6-10 pins)

3 KB3 RS-232C Modem Cable for Start-Stop Synchronous Communication KB4 RS-232C Null Modem Cable for Start-Stop Synchronous Communication marker (3) 46 Cable length 46 (3) F15E.ai KB3 RS-232C Modem Cable for Start-Stop Synchronous Communication (D-sub 25 - D-sub 25 male pins) -02 Cable length 2 m -05 Cable length 5 m -10 Cable length 10 m -15 Cable length 15 m Style Code *B Style B Note: If a RS-232C interface circuit at the partner equipment is insulated, use an AKB141 cable. KB4 RS-232C Null Modem Cable for Start-Stop Synchronous Communication (D-sub 25 - D-sub 25 male pins) -02 Cable length 2 m -05 Cable length 5 m -10 Cable length 10 m -15 Cable length 15 m Style Code *A Style A Note: If a RS-232C interface circuit at the partner equipment is insulated, use an AKB142 cable.

4 AKB141 For Connecting RS Circuit Isolated Devices RS-232C Modem Cable for Start-Stop Synchronous Communication AKB142 For Connecting RS Circuit Isolated Devices RS-232C Null Modem Cable for Start-Stop Synchronous Communication (3) 46 marker Cable length 46 (3) ACM CN1 I = 150 M3 Cable shield F16E.ai AKB141 For Connecting RS Circuit Isolated Devices RS-232C Modem Cable for Start-Stop Synchronous Communication (D-sub 25 - D-sub 25 male pins) For Connecting RS Circuit Isolated Devices AKB142 RS-232C Null Modem Cable for Start-Stop Synchronous Communication (D-sub 25 - D-sub 25 male pins)

5 AKB143 RS-232C Null Modem Cable for Start-Stop Synchronous Communication AKB144 RS-232C Null Modem Cable for Start-Stop Synchronous Communication 36.8 (3) 46 Cable length 38 (4) F17E.ai AKB143 RS-232C Null Modem Cable for Start-Stop Synchronous Communication (D-sub 25 - D-sub 9 male pins) Note: To comply with EMC Standards, connect a ferrite code (A1179MN) to this cable. Order it separately. AKB144 RS-232C Null Modem Cable for Start-Stop Synchronous Communication (D-sub 25 - D-sub 9 female pins) AKB161 RS-422/RS-485 Cable (Crimp terminal M4-M3) Cable length 10 20 30 40 80 Blue 70 M3 connector F18E.ai AKB161 RS-422/RS-485 Cable ( Crimp terminal M4-M3 ) Suffix Code -M Enter Cable length in every 5 m. Max. cable length 100 m (Suffix code: -M100).

6 AKB162 RS-422/RS-485 Cable (Crimp terminal M4-M4) Cable length 10 20 30 Blue 40 80 70 F19E.ai AKB162 RS-422/RS-485 Cable ( Crimp terminal M4-M4 ) Suffix Code -M Enter Cable length in every 5 m. Max. cable length 100 m (Suffix code: -M100). ORDERING INFORMATION Specify model, suffix codes and style code. TRADEMARK CENTUM is a registered trademark of Yokogawa Electric Corporation. Other company and product names appearing in this document are trademarks or registered trademarks of their respective holders. Subject to change without notice.