USB Smart Power Sensor

Similar documents
USB Smart Power Sensor

USB Smart Power Sensor

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

RC-1SP4T-A18. Key Features. Mini-Circuits P.O. Box 35166, Brooklyn, NY (718)

RCDAT The Big Deal

RUDAT Key Features. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Ideal for high dynamic range measurements from compression to noise floor

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

Broadband covering primary wireless communications bands: Cellular, PCS, LTE, WiMAX

iva Cable & Antenna Analyzer

iva Cable & Antenna Analyzer

Monolithic Amplifier PMA2-43LN+ Ultra Low Noise, High IP3. 50Ω 1.1 to 4.0 GHz. The Big Deal

Power Sensor/Meter with USB Interface Connect Directly to a PC

QuickSpecs. Model. HP USB HD 720p v2 Business Webcam. Overview

US-Key New generation of High performances Ultrasonic device

User Guide USB, RS232 & Ethernet Programable Attenuators

PL-2303 (Chip Rev H, HX, X) USB to Serial Adapter Windows Driver Installer Manual

Impedance 50 (75 connectors via adapters)

Micro HDMI to VGA with Audio Adapter. Quick Installation Guide. Introduction. Key Features and Benefits. System Requirements.

NI USB-5681 RF Power Meter Specifications

Pen Drive 2.0 Specification

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Agilent 8753ET/8753ES Network Analyzers

Universal Form-factor. Wi Fi Troubleshooting Made Easy

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

Point of view HDMI Smart TV dongle Mini RF Keyboard

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

Broadband covering primary wireless communications bands: Cellular, PCS, LTE, WiMAX

Multi-Range Programmable DC Power Supplies 9115 Series

SuperSpeed USB 7-Port Hub Quick Installation Guide

Field Calibration Software

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

USB Port Hub Quick Installation Guide

USB-Blaster Download Cable User Guide

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Measuring static magnetic fields

USB-500 Series Low-Cost Data Loggers and Accessories

USB 3.0 & Port Hub Quick Installation Guide

Symbol Parameters Units Frequency Min. Typ. Max. 850 MHz

Installation Guide for RadioLabs USB Wifi Antennas/Adapters

One Port Network Analyzer

R&S ZCxxx Millimeter-Wave Converters Specifications

SEE2 UV150 QUICK INSTALL GUIDE

Transmitter Interface Program

DC Electronic Loads 8500 series

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Understanding Mixers Terms Defined, and Measuring Performance

MADRIX NEO Quick Start Guide & User Manual

BTD-400 Bluetooth USB Adapter (Version 4.0)

Inserting the SIM card in the MobiGater device. Connecting the MobiGater Device

Parameter Min. Typ. Max. Units. Frequency Range GHz. Minimum Insertion Loss db. Dynamic 38 GHz 26 db

Signal Conditioning Amplifier System

Models HP HDMI to VGA Adapter HP EliteFolio Ethernet & VGA Adapter New! HP HDMI to DVI Adapter New! HP DisplayPort to HDMI 1.4 Adapter New!

DSA800 Series Spectrum Analyzer

Diagnostics Tools. for All Makes of agricultural machinery

1. SAFETY INFORMATION

Signal and Tracking Generator

US-SPI New generation of High performances Ultrasonic device

USB Plus+ RFID Reader Setup Guide

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Wahl C50 Calibrator FEATURES

How To Use A Sound Card With A Subsonic Sound Card

USB-AD16f Data acquisition system (USB)

BTD-300 Bluetooth USB Adapter (Version 3.0)

ViewLinker USB 2.0 Graphics Adapter

Compact EGC Amplifier Model 93251

SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd.

Laser Series. Laser. Leddura Lexinus Mensa. 84 inch UHD. Smart innovation! For when function matters.

User's Guide. Integrating Sound Level Datalogger. Model Introduction

3-Port FireWire 800/400 PCI Host Card

R&S SMZ Frequency Multiplier Specifications

Quick Operation Guide DAB, DAB + und DMB USB Digital Receiver Albrecht DR 403

Project Documentation EKTSDG Target Simulator Doppler Generator

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Pano Device. Data Sheet. How It Works: Key Benefits:

Turbo 85 Mbps Powerline Ethernet Adapter Model # APL8512. User s Manual. Ver. 1A

Radio Lab Transmitter Construction & Setup Guide

Targus Wireless Remote Presenter USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

PPS usable by timing applications via serial port emulation

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

AC Wi-Fi Range Extender RE355. Highlights. Description

ELAD FDM-S1 USER MANUAL. Ver. 1.01

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

USB-2.0 Mobile Mini Hub USER S GUIDE. Making Your Mobile Life Easier. Making Your Mobile Life Easier.

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

KS732 Family. Rev KS732. 1/3 CCD Color USB Camera

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

The Universal DAQ Device. Connect and measure immediately!

ST800K-U Optical Power Meter. User Manual V1.0

Before You Begin Installing Your Scanner

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

AC1450 Smart WiFi Router ac Dual Band Gigabit

USB-500/600 Series Low-Cost Data Loggers and Accessories

Barracuda Serial ATA

Installation Guide for RadioLabs USB Wifi Antennas/Adapters

USB 2.0 VGA ADAPTER USER MANUAL

Transcription:

Low Power Measurement 50Ω -45 dbm to +10 dbm, 50 to 6000 MHz The Big Deal USB HID device compatible with 32/64 Bit operating systems Includes GUI with measurement applications software, simplifying complex measurements Measure power levels as low as -45 dbm Measurement speed 30 msec CASE STYLE: JL2169 Product Overview The Mini-Circuits Smart Power Sensor is a pocket-sized, 4.95 x 1.74 x 1.08, precision test USB HID device (no driver installation required) that turns a Windows or Linux PC into a power meter. All specifications provided in the data sheet apply to continuous wave (CW) signals. Each unit is shipped with our N-to-SMA adapter and a quick-locking USB cable for reliable connectivity. User-Friendly GUI software, DLLs for programmers, user guide and detailed programming instructions are provided on the included CD or via download from minicircuits.com. Key Features Feature USB HID (Human Interface Device) GUI Measurement Application Software built-in Advantages Plug-and-Play (no need to install driver for the device). Enables the user to perform measurements on RF components such as Couplers, Filters, Amplifiers etc. and displays numerical data and graphs. 32/64 Bit operating systems Compatible with Windows and Linux operating systems. No calibration required before taking measurement Low power measurement The does not require any reference signal for calibration. The is capable of measuring signals as low as -45 dbm accurately and quickly Trademarks: Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Linux is a registered trademark of Linus Torvalds. Pentium is a registered trademark of Intel Corporation. Neither Mini-Circuits nor the Mini-Circuits PWR-series power sensors are affiliated with or endorsed by the owners of the above referenced trademarks Mini-Circuits and the Mini-Circuits logo are registered trademarks of Scientific Components Corporation. www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 1 of 5

Low Power Measurement 50Ω 50 to 6000 MHz Product Features 55 db Dynamic Range, -45 to +10 dbm Good VSWR, 1.10:1 typ. Fast measurement speed, 30 msec typ. Automatic frequency calibration & temperature compensation Multi-sensor capability (up to 24) Built in Application Measurement Software Effective, easy-to-use Windows GUI Compatible with 32/64-bit Windows or Linux operating systems Supports a wide range of programming environments (See application note AN-49-001 for details) CASE STYLE: JL2169 Model No. Included Accessories PWR-SEN-6LGHS USB-CBL-3+ NF-SM50+ PWR-SEN-CD USB smart Power Sensor Power Sensor Head 6.6 ft data cable (USB Type-A Plug) N-Type (F) to SMA(M) Adapter Typical Applications Turn almost any Windows or Linux PC into a Power Meter Pocket-sized portability for benchtop testing anywhere Remote location monitoring Automatic, scheduled data collection Evaluate high-power, multi-port devices with built-in virtual couplers/attenuators & other software tools Wide variety of applications including testing Wi-Fi and Bluetooth products RoHS Compliant See our web site for RoHS Compliance methodologies and qualifications Mini-Circuits Power Meter Program for Smart Power Sensor Rev. OR M154921 EDR-11185/2 RAV 160327 www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 2 of 5

Electrical Specifications(CW) 1, -45 dbm to +10 dbm, 50 to 6000 MHz Freq. Range Min. Typ. Max. Units Dynamic Range 2 50-6000 -45 - +10 dbm VSWR 50-6000 - 1.10 1.30 :1 Uncertainty of Power Measurement @ 25ºC Uncertainty of Power Measurement @ 0ºC to 50ºC @ -45 to -40 dbm 3,4 50-3000 - ±0.15 ±0.35 db 3000-6000 - ±0.15 ±0.45 db @ -40 to -10 dbm 3,4 50-3000 - ±0.10 ±0.35 db 3000-6000 - ±0.10 ±0.40 db @ -10 to +10 dbm 50-3000 - ±0.10 ±0.35 db 3000-6000 - ±0.10 ±0.40 db @ -45 to -40 dbm 3,4 50-3000 - ±0.30 - db 3000-6000 - ±0.30 - db @ -40 to -10 dbm 3,4 50-3000 - ±0.20 - db 3000-6000 - ±0.20 - db @ -10 to +10 dbm 50-3000 - ±0.20 - db 3000-6000 - ±0.20 - db Linearity @ 25ºC 50-6000 - ± 1.6 - % Measurement Resolution 50-6000 0.01 - - db Averaging Range 50-6000 1-999 - Measurement @ Low Noise Mode - 100-50 - 6000 msec Speed @ Faster Mode - 30 - Current (via host USB) 50-6000 - 80 110 ma 1 All specifications apply to continuous wave (CW) signals. 2 Maximum continuous safe operational power limit: +13 dbm. 3 When using Faster mode at high frequencies below -30dBm, use of averaging is recommended to prevent noise errors. 4 When using Faster mode below -30dBm, uncertainty value may increase by up to 0.2 db relative to Low noise mode Minimum System Requirements Interface Host operating system - USB control Hardware USB cable (supplied) USB HID Requirements Windows 32/64 Bit operating system: Windows 98, Windows XP, Windows Vista, Windows 7, Windows 8, Windows 10 Linux support: 32/64 Bit operating system Pentium II or higher, RAM 256 MB Power sensor to be used with the supplied USB cable only Absolute Maximum Ratings Ratings Operating Temperature 0 C to 50 C Storage Temperature -30 C to 70 C DC Voltage at RF port CW Power 16 V +15 dbm www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 3 of 5

VSWR (:1) (:1) Typical Performance Curves 1.25 1.20 1.15 1.10 1.05 0 C +25 C +50 C VSWR VSWR UNCERTAINTY (db) UNCERTAINTY (db) UNCERTAINTY OF POWER MEASUREMENT UNCERTAINTY OF CW POWER SIGNAL@ MEASUREMENT 25 C @ 25 O C 0.30 0.15 0.00-0.15 @-45dBm @-40dBm @-30dBm @-20dBm @-10.3dBm @0dBm @+5dBm @+10dBm 1.00 0 1000 2000 3000 4000 5000 6000 FREQUENCY -0.30 0 1000 2000 3000 4000 5000 6000 FREQUENCY 2% LINEARITY @ 25 C O C 0% Linearity LINEARITY (%) (%) -2% -4% -6% -45 to -10 dbm -10 to +10 dbm Outline Drawing (JL2169) -8% 0 2000 4000 6000 FREQUENCY Frequency Push-Pull Connector Note 5 LED Indicator C E ±1.0" A D N-Type Male Connector USB Type A Plug B Power Indicator inch Outline Dimensions ( mm ) A B C D E 4.95 1.74 1.08 3.63 81.9 125.7 44.2 27.4 92.2 2080 5 Power sensor to be used with the supplied USB cable only. WT. GRAMS 250 www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 4 of 5

Ordering Information Model Included Accessories Part No. PWR-SEN-6LGHS Power Sensor Head PWR-SEN-CD Software CD USB-CBL-3+ 6 6.6 ft data cable with USB Type-A plug connector NF-SM50+ N-Type Female to SMA Male Adapter. 6 Power sensor to be used with the supplied control cable only. Optional Accessories USB-CBL-3+ (spare) NF-SM50+ (spare) 6.6 ft data cable with USB Type-A plug connector N-Type Female to SMA Male Adapter. Calibration CALSEN-6LGHS Calibration Service Click Here Additional Notes A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document. B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit s applicable established test performance criteria and measurement instructions. C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, Standard Terms ); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits website at www.minicircuits.com/mclstore/terms.jsp www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 5 of 5