Transmitting e-mails with the WAGO IPC 758-870 Application note



Similar documents
Transmitting s in a local network with a WAGO CONTROLLER Application note

Remote Connection to a WAGO using a High-Speed Internet connection Application note

Ethernet PFC Sending Application note

Transmitting s with the library "WagoLibMail_02.lib" Application note

WAGO PFC 750-8xx Interface to Horner HMI Application note

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

Connect Ethernet-Controller to TO-PASS web portal via GPRS-Router Application note

WAGO-I/O-SYSTEM in ABB robot control systems Application note

Accessing EtherNet/IP Network Variables in a WAGO with a ControlLogix PLC Application note

Sending / receiving SMS using a GSM modem Application note

Ethernet/IP Comms between a WAGO and a Mettler Toledo JAGXTREME Terminal Application note

Using the SysLibFile.lib and the WagoLibFtp.lib for file access Application note

Application note. A103202, English Version 1.0.1

Using library WagoLibMySQL to communicate with MySQL-Databases Application note

Configuration a Profibus-DP node using Step7 and WAGO-I/O components Application note

WAGO PFC as a MODBUS MASTER Application note

Application Note. WAGO EtherNet/IP Communications with a CompactLogix PLC Using Explicit Messaging. A500620e, English Version: 1.0.

EtherNet/IP communications between a WAGO PFC and a SICK IVC-2D Camera Application note

WAGO-I/O-SYSTEM. Using library WagoLibMSSQL_03.lib in CoDeSys 2.3 for interface to Microsoft SQL Server 200x. Application Note

Modular I/O System ETHERNET StarterKit Quick Start ETHERNET Fieldbus Controller

Using library WagoLibHttp_02.lib to communicate with remote web server Application note

WAGO Software CODESYS Library WagoLibDiagnosticIDs.lib for accessing the internal diagnostics protocol

Modular I/O System Quick Start for WAGO-I/O-IPC /000-xxx Features

INTEGRATION GUIDE. General Radius Config

THE KNX IP CONTROLLER. Taking Proven Technology to the Next Level

ewon-configuration for Internet Access using the Wizard How to

RELEASE NOTES Product Version: 7.2 Date: November, 2015

Manual. Source Control. TwinCAT 3. Version Date

VPN Configuration Guide. Parallels Remote Desktop for Mac

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

archiving for Microsoft Outlook and Exchange Server

Collax Mail Server. Howto. This howto describes the setup of a Collax server as mail server.

SUPPORT GUIDE FOR SETTINGS IN NOKIA 6600 IMAGING PHONE

602LAN SUITE 5.0 Groupware

GFI White Paper: GFI FaxMaker and HIPAA compliance

Brief Information LAN/USB Interface. Art. no st edition, 10 11

Manual TC3 PLC HMI. TwinCAT 3. Version: Date: Order No.: TF1800

QuesCom FS400 Fax & SMS Communication Router

bintec Workshop IP Load Balancing Copyright November 8, 2005 Funkwerk Enterprise Communications GmbH Version 0.9

bintec Workshop WAN Partner Configuration Copyright November 8, 2005 Funkwerk Enterprise Communications GmbH Version 0.9

Configuration Example

Trend Micro Encryption Gateway 5

Archiving with MS Exchange Server

Alignment and Couplings

Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice.

Standard diagnostic and configuration interface for Beckhoff Industrial PCs

SENDING WITH ENTRAPASS CORPORATE EDITION

ing from The E2 Shop System address Server Name Server Port, Encryption Protocol, Encryption Type, SMTP User ID SMTP Password

Linking 2 Sites Together Using VPN How To

User Guide bintec R230a / R230aw / R232b/ R232bw ADSL. Copyright April 18, 2006 Funkwerk Enterprise Communications GmbH Version 2.

Service Schedule for Business Lite powered by Microsoft Office 365

WaveWare Technologies, Inc. We Deliver Information at the Speed of Light

Chapter 5 Customizing Your Network Settings

ABB solar inverters. User s manual ABB Remote monitoring portal

How To Install And Manage Exchange 2007 With Hostda.Com (Hostda) On A Single Server With Hostdroid (Hostdda) (Hostmaster) ( (Webmaster) And Hostda (Hosting

1WLAN CONFIGURATION WITH WEP

Issue 2EN. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

White paper Power Consumption Monitoring of PRIMERGY Servers in System Center Operations Manager

Service Managed Gateway TM. How to Configure a T1/E1 Connection

Microsoft Exchange Load Balancing. Unique Applied Patent Technology By XRoads Networks

PrivaSphere Gateway Certificate Authority (GW CA)

Safety information. MSX-Box. ADDI-DATA GmbH Airpark Business Center Airport Boulevard B Rheinmünster Germany

Figure 41-1 IP Filter Rules

How to set up Inbound Load Balance under Drop-in Mode

OmniTouch 8400 Instant Communications Suite. My Instant Communicator for Microsoft Outlook User guide. Release 6.7

emobility WAGO Leading the Charge

VPN Configuration Guide. Linksys (Belkin) LRT214 / LRT224 Gigabit VPN Router

User Manuals. Connection to Siemens S5 PU (AS511) Part Number: Version: 2. Date:

SME- Mail to SMS & MMS Gateway with NowSMS Quick Start Guide

Monitoring and Troubleshooting Microsoft Exchange Server 2007 (5051A) Course length: 2 days

Nokia for Business. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

Sage 200 Web Time & Expenses Guide

SoftRAID 5 QUICK START GUIDE. for OWC ThunderBay

Oracle Enterprise Manager

MOC 5047B: Intro to Installing & Managing Microsoft Exchange Server 2007 SP1

Configuring Your Client: Outlook Express. Quick Reference

Oracle Enterprise Manager

Novar Database Mail Setup Guidelines

Flow Publisher v1.0 Getting Started Guide. Get started with WhatsUp Flow Publisher.

Special Terms and Conditions for HGC Business Services

Chapter 1 Implement EIGRP operations Chapter 2 Implement multiarea OSPF operations Chapter 4 Implement Cisco IOS routing features...

Designing a Microsoft Exchange Server 2003 Organization

IP POWER 9258 USER MANUAL IP POWER 9258 USER MANUAL

Metalogix Storage Expert Installation Guide

Networking Basics for Automation Engineers

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Talk2M ewon Internet Connection How To

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

P-3202H-Bb. G-PON VoIP IAD DEFAULT LOGIN DETAILS. Firmware v1.0 Edition 1, 09/2009. IP Address: Password: 1234

WatchGuard XCS Exam Study Guide

Configuring Your Client: Outlook Express

ONE Mail Direct. Privacy Impact Assessment Summary

Configuring Your Client: Eudora 5.x

Configuring Notification for Business Glossary

ABB solar inverters. User s manual ABB Remote monitoring portal

Smartermail. Web interface & Outlook/Live Mail setup guide. Date: Version: 3. Author: Mikkel Bredahl Dreyer. Target Level: Customer

Transcription:

Transmitting e-mails with the WAGO IPC 758-870, English Version 1.0.0

2 General Copyright 2005 by WAGO Kontakttechnik GmbH All rights reserved. WAGO Kontakttechnik GmbH Hansastraße 27 D-32423 Minden Phone: +49 (0) 571/8 87 0 Fax: +49 (0) 571/8 87 1 69 E-Mail: info@wago.com Web: http://www.wago.com Technical Support Phone: +49 (0) 571/8 87 5 55 Fax: +49 (0) 571/8 87 85 55 E-Mail: support@wago.com Every conceivable measure has been taken to ensure the correctness and completeness of this documentation. However, as errors can never be fully excluded we would appreciate any information or ideas at any time. We wish to point out that the software and hardware terms as well as the trademarks of companies used and/or mentioned in the present manual are generally trademark or patent protected.

Table of Contents 3 TABLE OF CONTENTS 1 Important comments...4 1.1 Legal principles...4 1.1.1 Copyright...4 1.1.2 Personnel qualification...4 1.1.3 Intended use...4 1.2 Range of validity...5 1.3 Symbols...5 2 Description...6 3 Solution...7 3.1 E-mail to mail server in the Intranet...7 3.2 E-mail to mail server in the Internet...8 4 Example WagoLibMail_01_example_v1.pro...9

4 Important comments 1 Important comments 1.1 Legal principles 1.1.1 Copyright To ensure fast installation and start-up of the units described in this manual, we strongly recommend that the following information and explanation is carefully read and adhered to. This manual is copyrighted, together with all figures and illustrations contained therein. Any use of this manual which infringes the copyright provisions stipulated herein, is not permitted. Reproduction, translation and electronic and photo-technical archiving and amendments require the written consent of WAGO Kontakttechnik GmbH. Non-observance will entail the right of claims for damages. 1.1.2 Personnel qualification 1.1.3 Intended use The use of the product detailed in this manual is exclusively geared to specialists having qualifications in PLC programming, electrical specialists or persons instructed by electrical specialists who are also familiar with the valid standards. WAGO Kontakttechnik GmbH declines all liability resulting from improper action and damage to WAGO products and third party products due to non-observance of the information contained in this manual. For each individual application, the components supplied are to work with a dedicated hardware and software configuration. Modifications are only admitted within the framework of the possibilities documented in the manuals. All other changes to the hardware and/or software and the non-conforming use of the components entail the exclusion of liability on part of WAGO Kontakttechnik GmbH. Please direct any requirements pertaining to a modified and/or new hardware or software configuration directly to WAGO Kontakttechnik GmbH.

Important comments 5 1.2 Range of validity 1.3 Symbols This application note is based on the stated hardware and software of the specific manufacturer as well as the correspondent documentation. This application note is therefore only valid for the described installation. New hardware and software versions may need to be handled differently. Please note the detailed description in the specific manuals. Danger Always observe this information to protect persons from injury. Warning Always observe this information to prevent damage to the device. Attention Marginal conditions must always be observed to ensure smooth operation. ESD (Electrostatic Discharge) Warning of damage to the components by electrostatic discharge. Observe the precautionary measure for handling components at risk. Note Routines or advice for efficient use of the device and software optimisation. More information References to additional literature, manuals, data sheets and INTERNET pages

6 Description 2 Description Use of the library "WagoLibMail_01" for dispatching e-mails with the WAGO IPC 758-870 -directly to a mail server in the Intranet. -directly to a mail server in the Internet over a router. Reference Material The connection was tested under the following prerequisites. Assigned hardware components: WAGO IPC ISDN Router 758-870 (Release01) BinTec - X1000 Assigned software components: CAA V2.3.3.6 WagoLibMail_01.lib Version 1.0 WagoLibMail_01_example_v1.pro Example project Microsoft Outlook 2000 WAN: Internet Provider Mail Provider Arcor, Freenet Web.de

Solution 7 3 Solution The WAGO IPC offers among other things the possibility to dispatch e-mails. For this purpose two functional modules are made available in the library WagoLibMail_01.lib, which allows the user to send a mail without knowledge of the mail protocol (SMTP). In the following two versions are demonstrated. Both versions are covered by the example. Depending on the selected version additional tools will be used for configuration. 3.1 E-mail to mail server in the Intranet The example permits transmitting e-mails of any sender to a certain e-mail address in the Intranet. Prerequisites: - Mail server in network: e.g.: ArGoSoft-Mail-Server - Account for mail server: e.g.: MyLocalAccount/MyLocalPassword E-mail address: e.g.: MyLocalEmail@MyDomain.com IP: 10.1.5.3 SM: 255.255.0.0 WAGO 758-870 Recipient Ethernet Mail Server IP: 10.1.5.2 SM: 255.255.0.0 Important parameters of the WAGO IPC and Mail server are: - IP address. - network mask.

8 Solution 3.2 E-mail to mail server in the Internet The example permits transmitting e-mails to any recipient by Internet. A valid mail server account of an Internet service provider (ISP) is needed as sender. Prerequisites: - ISDN-Router Mail server in Internet: e.g.: web.de - Account for mail server: e.g.: MyWebAccount/MyWebPassword E-mail address: e.g.: MyEmail@web.de IP: 10.1.5.2 SM: 255.255.0.0 GW: 10.1.250.1 WAGO 758-870 Recipient IP: 10.1.250.1 SM: 255.255.0.0 Ethernet ISDN-Router ISDN ISP-Mail-Server (web.de) SMTP-Server: 217.72.192.134 POP3-Server: 217.72.192.157 Important parameters of the WAGO IPC are: - IP addresses. - network mask. - IP address of the ISDN-Router as gateway.

Example WagoLibMail_01_example_v1.pro 9 4 Example WagoLibMail_01_example_v1.pro The user interface of the function block Mail_SMTP_Client is shown below. By setting the variable xsend to True a mail will be transmitted. Transmitting e-mails over the Internet makes use of different authorization methods. One way is done by the POP 3 protocol. With the function block MAIL_Pop3_Client it is assumed that authorization by POP3 protocol, in accordance with «Pop3 before SMTP», at the mail provider is possible. Furthermore a fixed IP address for the SMTP- und POP3 server is assumed.

WAGO Kontakttechnik GmbH Postfach 2880 D-32385 Minden Hansastraße 27 D-32423 Minden Phone: 05 71/8 87 0 Telefax: 05 71/8 87 1 69 E-Mail: info@wago.com Internet: http://www.wago.com