PFT Two stage axial fan The high pressure fan for modern boiler plants



Similar documents
Fläkt Woods Building Future

Precise Air Management Product Range > Car Park Ventilation

Green Buildings. Energy Efficient Air Climate Solutions ENERGY EXPERTISE ENVIRONMENT

System solution for data centres

Solutions for Building Air Comfort and Fire Safety

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

eq Top/TopMaster Air Magic by Fläkt Woods

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Energy Efficiency HOSPITALITY.

THE ErP DIRECTIVE 2009/125/EC KEY FACTS» REGULATIONS 327/ /2009. ErP. - Version 2.0

Chapter 3.5: Fans and Blowers

Data Centres A complete solution to noise control and acoustic packages

We have been working in an ideal climate for thirty years.

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

Hydraulically actuated clutches and spring-applied brakes clutch/brake combined units

Oil & Gas. CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition.

lindab ventilation Solutions for ventilation

HVAC Systems: Overview

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

Operataing Manual. Single stage radial Fan. Model MKV/TKV

Dampers. Inlet guide vane. Damper. Louvre damper. Handbook Radial Fans / Chapter 3 - Dampers REITZ List 2010 DO 1. Dampers

Air-water systems for efficient air conditioning

TABLE OF CONTENT

TCA Turbocharger. The benchmark

HVAC Processes. Lecture 7

"AC2EC" - Replacement made easy New EC motor design Compact and efficient

Waterjets. propulsors. courtesy of Austal

University of St Andrews. Energy Efficient Data Centre Cooling

Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.

Ventilation Solutions Product Range > Car Park Ventilation, 50Hz

RPV - RP - RA air handling units

Transformer oil cooler ALFA A02

Energy Efficiency. Bars & RestauRants.

RiMatrix S Make easy.

Hydraulic Control Technology for Wind Turbine Generators

How To Get A Passive House

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Zehnder Focus 200. Ventilation device

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Rotary screw compressors kw 5,5 7, , bar MODULO

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Intelligence down to the last detail.

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Creating Efficient HVAC Systems

ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Norbro Series 40R Pneumatic Actuator Double Acting or Spring Return

FAN PROTECTION AGAINST STALLING PHENOMENON

Acoustic Design Practices for Sustainable Buildings

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Heating, ventilation and air conditioning (HVAC) equipment. A guide to equipment eligible for Enhanced Capital Allowances

- White Paper - Data Centre Cooling. Best Practice

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Torque motors. direct drive technology

All the best brands all under one roof

Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Glossary of HVAC Terms

Resources for School Energy Managers

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

FAN SYSTEM REPLACEMENTS IN HVAC EQUIPMENT TO IMPROVE ENERGY

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Ventilation Solutions Product Range > Car Park Ventilation, 50Hz

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Offshore Substation. HVAC System. ETS-09 Rev. 2. technical standards. Dok Sag 09/1437

NAISSUS THERMAL MANAGEMENT SOLUTIONS

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

Nominal Life Expectancy for Building Components

Cool air quietly and efficiently. A guide to buying and operating an air conditioner

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

Using Portable Spot Air Conditioners in Industrial Applications

State of the Art Energy Efficient Data Centre Air Conditioning

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

WÄRTSILÄ CONTROLLABLE PITCH PROPELLER SYSTEMS

lindab we simplify construction Air Handling Units Product Overview

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

News in Data Center Cooling

HEATING, VENTILATION & AIR CONDITIONING

Rotary vane steering gear for smaller vessels

ASTACEA4 Inspect complex/central air conditioning systems

Basic Hydraulics and Pneumatics

Scope of Work. See for resources available

Mobile field balancing reduces vibrations in energy and power plants. Published in VGB PowerTech 07/2012

DOEN THRUSTMASTER WATER JETS. 100 Series. 100kW to 900kW. History. Innovation. Power. thrustmaster.net

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Introduction to Process Control Actuators

OHV / OHVL Type OH3 Vertical Inline Pumps ISO (API 610)

Butterfly Valves PN 6/10/16 for flanged connection

Vertical Multistage Centrifugal Electric Pumps SV Series NEW LASER TECHNOLOGY

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min.

ROTEX gas hybrid heat pump. A strong team.

Pump Shaft Sleeves - Stratford Engineering

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

HVAC Made Easy - Selection Tips for Chiller Compressors

Transcription:

PFT Two stage axial fan The high pressure fan for modern boiler plants

Modern boilers equipped with complete flue-gas cleaning systems demand fans for high pressure that can be controlled quickly and accurately The above PFT fan is in operation at the Fyriskraft power plant in Uppsala, Sweden. The impellers have a diameter of 3.15 m. Power demand is 3.2 MW on the fan shaft.

PFT the boiler fan for tough performance requirements Fläkt Woods PFT axial fan combines compact size for minimum space requirements with high pressure, and high efficiency, throughout its entire operating range. PFT is a two stage axial flow fan which develops double the pressure rise compared to that of a conventional single stage fan. The fan has two impellers mounted on a common shaft with a guide vane arrangement between the two impellers. The fans operating point is quickly adjusted to the systems load demand by varying the pitch of the hydraulically adjustable impeller blades. PFT fans are recognised for: Reliability Stable performance Ease of maintenance The PFT axial is a high-pressure fan offering exceptional operating economy, a number of installation advantages, accurate and troublefree control, plus low maintenance costs Fläkt Woods PFT axial the optimum choice for your next forced draft or induced draft fan.

PFT the high-pressure PFT s overall design features makes it a unique axial. Here s why: The fans design ensures high aerodynamic performance throughout its entire operating range, as documented from installations around the world. The fan will be equipped with Fläkt Woods Stall Warning System for safe operation. You always choose the optimal fan for your installations due to the large range of PFT models with varying impeller diameters, hub sizes and speeds. The operating range covers duties up to 1000 m3/s and 30 kpa. The two shaft bearings are positioned with one impeller between the bearings and the other on the free shaft end for high rigidity. This arrangement provides substantial vibration and resonance advantages, combined with high accessability.

fan with unique features No external actuator is needed for the PFT axial since the control mechanism, including its hydraulic cylinder, is integrally built into the fan hub. With this design, control forces are not transmitted externally. The blades are controlled by a minimum number of moving parts, giving high reliability, low friction and long operating life. The servo system controlling blade positioning eliminates all hysteresis problems. The unique blade thrust bearing arrangement gives a low bearing load together with guaranteed continuous pressure lubrication of the bearings - the basic requirements for low control forces and long bearing life.

Details that make PFT axials th Limit Switch Positioner From Controler Servo Card Converter Hydraulic Unit including Servo Valve Quick and responsive control system The control system quickly and accurately adjusts the PFT fan s operating point to meet system requirements by adjusting the pitch of the blades. The blades are adjusred by means of a hydraulic cylinder built into the impeller hub. A minimum of moving parts are required to transfer the cylinder s movement to the blades of both impellers. The hydraulic cylinder is controlled by a doubleacting servo valve responding to a signal from the control unit. The cylinder repositions the blade angle from the current position to the required position. This monitoring function provides fast and precise control without hysteresis. Blade thrust bearings with long operating life Placing of the blade thrust bearings at a maximum distance from the centre of the impeller enables larger bearings to be used resulting in lower bearing load. The blade thrust bearings are subject to loads from the blade and the bearing mounting only and not from a blade shaft.

e most economical alternative Fläkt Woods unique lubricating system lubricates the blade thrust bearings. With the bearing housing tightly enclosed under a plate cover all lubrication grease remains in the bearing assembly and the lubrication system is not affected by any shaft sealing arrangement. This design prevents ingress of foreign matters, such as gas or particles, which can adversely effect bearing functions and life. The fan that s simple to service Fläkt Woods PFT fan is easy to maintain. We design the axial fans to operate over long periods without the need for maintenance, to keep service requirements to a minimum. Inspection doors are strategically located on the fan for quick and easy maintenance and service. PFT s design principle gives you a fan of the longest possible operating life due to: a low load on bearings guaranteed continuous lubrication of blade thrust bearings under pressure no risk for fouling the lubricant no corrosion risk Fan capacity range

We Bring Air to Life Fläkt Woods is a global leader in air management. We specialise in the design and manufacture of a wide range of air climate and air movement solutions. And our collective experience is unrivalled. Our constant aim is to provide systems that precisely deliver required function and performance, as well as maximise energy efficiency. Solutions for all your air climate and air movement needs Fläkt Woods is providing solutions for ventilation and air climate for buildings as well as fan solutions for Industry and Infrastructure. Air Handling Units (AHUs) Modular, compact and small AHU units. Designed to ensure optimisation of indoor air quality, operational performance and service life. Air Terminal Devices and Ducts Supply and exhaust diffusers and valves for installation on walls, ceiling or fl oor are all included in our large range and fi t all types of applications. Chilled Beams Active induction beams for ventilation, cooling and heating, and passive convection beams for cooling. For suspended or fl ush-mounted ceiling installation and multi-service configuration. With unique Comfort Control and Flow Pattern Control features. Residential ventilation A complete range of products for residential ventilation. Consists of ventilation units, exhaust air fans and cooker hoods designed to optimise indoor comfort and save energy. Energy recovery Dessicant-based product and systems that recover energy, increase ventilation and control humidity. Fans Advanced axial, centrifugal and boxed fans for general and specialist applications. Comprehensive range including high temperature and ATEX compliant options. Engineered for energy effi ciency and minimised life cycle cost. Chillers Air-cooled and water-cooled chillers with cooling capacity up to 1800kW. Designed to minimise annual energy consumption in all types of buildings. Controls and drives Variable speed drives and control systems, all tested to ensure total compatibility with our products. Specialist team can advise on energy saving and overall system integration. Acoustical Products A complete line of sound attenuating products, including rectangular and round silencers, Media Free silencers, custom silencers and acoustic enclosure panels FWG-Two stage axial fan-brochure-gb-10a-8951 GoodRace communication Fläkt Woods AB Kung Hans väg 12 SE-192 68 Sollentuna Tel. 0771-26 26 26 www.flaktwoods.se