LifeStent XL Biliary Stent System



Similar documents
Bard LifeStar Biliary Stent System

Instructions for Use. Device Description The AMPLATZER Vascular Plug II is a self-expandable nitinol mesh occlusion device (see Figure 1).

AERO. Tracheobronchial Stent Technology System

Aspira* Peritoneal Drainage Catheter

Allium Ureteral Stent (URS)

Aspira* Pleural Drainage Catheter

WallFlex Biliary RX Stent. Fully, Partially and Uncovered Self-Expanding Metal Stents

Contraindications: Malign or benign strictures in the upper part of esophagus close to the cricopharyngeal muscle.

Bard LifeStar Vascular Stent System

Vascular Stent System (6F, mm stents)

Instructions for Use. Cordis S.M.A.R.T. CONTROL Vascular Stent System

A Guide for Patients Living with a Biliary Metal Stent

RELAY Plus Thoracic Stent-Graft System with Transport Delivery System

Allium Bulbar Urethral Stent System (BUS) Instructions For Use

Instructions For Use

PERCUTANEOUS PD CATHETER IMPLANTATION SYSTEM

PATIENT INFORMATION BOOKLET

ON-Q * Catheters and Introducers

Subject: Magnetic Resonance Imaging (MRI) Information on Sorin Group Heart Valve Prostheses and Annuloplasty Devices

Tracheal Stent System

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

Supera Peripheral Stent System Instructions for Use

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

Replacement Heart Valve Product Description (Stented Tissue) Models Reference

Wingspan Stent System with Gateway PTA Balloon Catheter

GRAFTMASTER RX Coronary Stent Graft System PPL (2/1/13)

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

Posterior Referencing. Surgical Technique

Innova Vascular OVER-THE-WIRE

REVEAL LINQ LNQ11. Insertable Cardiac Monitor MRI procedural information. MRI Technical Manual

12 pericardial bioprostheses. 7300TFX Carpentier-Edwards bioprosthetic valved conduit

Jugular/Subclavian Vein Approach Instructions for Use

PERIPHERALLY INSERTED CENTRAL CATHETERS (PICC) Fong So Kwan APN, Haematology unit Medical Department, QMH

Bard Access Systems, Inc. How to Care For Your. Nursing Guide

Cook Celect and Günther Tulip Vena Cava Filter Patient Guide

When Procedural Support really matters. Navien TM A+ Intracranial Support Catheter

Hickman*, Leonard* and Broviac* Central Venous Catheters

Allium Triangular Prostatic Urethral Stent System (TPS) Instructions For Use

HUNTER TENDON IMPLANTS

Instructions for Use

Morpheus SMART PICC CT Insertion Kit

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

BARD MEDICAL DIVISION UROLOGICAL DRAINAGE. Foley Catheter Care & Maintenance. Patient Education Guide

Hemostasis Solutions Boston Scientific is committed to improving patient care in the management of gastrointestinal bleeding.

Table of Contents. PowerPort* Implantable Port. PowerPort* Devices. PowerLoc* Safety Infusion Set Family Devices. Troubleshooting Guide 14

Overview of Newer Stent Devices for Aneurysm Treatment

HELPFUL STEP-BY-STEP ILLUSTRATIONS ARE LOCATED IN THIS BOOKLET

2009/JUL/20 at 9:18 a.m. Doc number: M710950B001 [Uni+] VALIANT THORACIC STENT GRAFT WITH THE CAPTIVIA DELIVERY SYSTEM Instructions for Use

Instructions for Use Cordis PRECISE Nitinol Stent System (5.5F and 6F)

MR Information Date: March 11, 2014

Bile Leaks After Laparoscopic Cholecystectomy. Kings County Hospital Center Eliana A. Soto, MD

I-140 Venipuncture for Blood Specimen Collection

Syringe. Product Usage Information: Precautions:

A Practical Guide for the selection and use of prefilled Syringes for flushing vascular access devices. Paul Parisien, MedXL inc., Montreal, Canada.

PICC & Midline Catheters Patient Information Guide

Malfunctioning PD Catheters

Central Venous Lines, PICCs, Ports and Pumps

6900PTFX bioprosthesis Carpentier-Edwards PERIMOUNT Magna mitral pericardial

Arrow NextStep and Arrow Cannon II Plus Chronic Hemodialysis Catheters

Flushing and Dressing a Peripherally Inserted Central Catheter (PICC Line): a Guide for Nurses

USE OF STENTS FOR UPPER GI DISASTERS. Michael Talbot. The St George Hospital, Sydney

Biliary and Endovascular Product Catalog

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

Power Injectors for Diagnostic Imaging

External Fixation Systems IMPORTANT MEDICAL INFORMATION

A Patient s Guide to Minimally Invasive Abdominal Aortic Aneurysm Repair

A GUIDE TO HAVING PERCUTANEOUS TRANSHEPATIC CHOLANGIOGRAM (PTC) AND BILIARY DRAIN/DILATATION/STENTING

Clinician Competency:

Placement of Epidural Catheter for Pain Management Shane Bateman DVM, DVSc, DACVECC

Achilles Tendon Repair, Operative Technique

FDA Guidelines for Magnetic Resonance Equipment Safety

I. Questions for VAD slide program

Use of stents in esophageal cancer" Hans Gerdes, M.D. Director, GI Endoscopy Unit Memorial Sloan-Kettering Cancer Center

XIENCE V and Magnetic Resonance Imaging Examination

Table 1. Balloon and Stent Specifications. Nominal Pressure During Stent Deployment (atm/kpa) Stent Length (mm)

Standard laryngoscope blade assemblies Directions for use

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

Biliary Stone Disease

A PATIENT S GUIDE TO ABLATION THERAPY

A PROCEDURAL GUIDE TO MIDLINE CATHETER INSERTION

Instructions and User Guide. Select Series: Vascular Access Ultrasound Training Models BPO100, BPBV110, BPP120, BPNB150. June 8, 2011 Rev 2.

ERCP in Post Surgical Anatomy

STAY-PUT Nasojejunal Feeding Tubes. Nursing Manual/ Patient Information

Sterile Dressing Change with Tegaderm CHG for Central Venous Catheter (CVC)

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

A. ADMINISTERING SUBCUTANEOUS MEDICATIONS INTERMITTENTLY/CONTINUOUSLY B. (SUBCUTANEOUS INFUSION) HYDRODERMOCLYSIS

Biliary Drain. What is a biliary drain?

Zimmer Small Fragment Universal Locking System. Surgical Technique

Talent Thoracic Stent Graft with THE Xcelerant Delivery System. Expanding the Indications for TEVAR

Lentur Cable System. Surgical Technique

Use and Disposal of Sharps

MRI SAFETY JEOPARDY (Technologist Edition) Questions

A4.7 Management of a totally occluded central catheter and persistent withdrawal occlusion (PWO)

CamSplice Assembly Manual

RX Herculink Elite Renal and Biliary Stent system Instructions for Use. RX Herculink Elite Renal Stent System. Table of Contents

TwinFix Cannulated Compression Screw

MatrixNEURO. The next generation cranial plating system.

HUMULIN 70/30 KwikPen

PATIENT GUIDE. Understand and care for your peripherally inserted central venous catheter (PICC). MEDICAL

Transcription:

B05688 Rev.2/07-13 LifeStent XL Biliary Stent System Recommended Guidewire Length Table Catheter Working Length Recommended Guidewire Length 130 cm 300 cm 80 cm 260 cm 130 cm & 80 cm 160 cm & 110 cm Figure 1. LifeStent XL Biliary Delivery System CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. its unconstrained diameter upon deployment into the biliary duct. Upon deployment, the stent imparts an outward radial force on the luminal surface of the duct to establish patency. For single use only Device Name The device brand name is the LifeStent XL Biliary Stent System. Description The LifeStent XL Biliary Stent System is designed to deliver a self-expanding stent to the biliary tree via a sheathed delivery system. The LifeStent XL Biliary Stent System is comprised of the following: An implantable self-expanding nickel-titanium alloy (nitinol) stent (1), as shown in Figure 1 and Figure 2. The stent is a flexible, fine tubular mesh prosthesis, with a helical design, which achieves 1 Figure 2. LifeStent XL Biliary Stent A delivery system, as shown in Figure 1, comprised of an innertubing assembly that contains the guidewire lumen, a stent delivery sheath (2) and a system stability sheath (3), which are linked together by means of a handle (4). The guidewire lumen terminates distally in an atraumatic catheter tip (5) and originates proximally in a luer hub (6) designed to accept a compatible guidewire. The self-expanding stent is constrained in the space between the guidewire lumen and stent delivery sheath. Unintended stent movement during sheath retraction is restricted by the delivery system. The stent delivery sheath has a radiopaque zone (7) at its distal end. The stent delivery

system has a second radiopaque zone (9) proximal to the stent. Prior to deployment the shipping lock (8) must be removed and discarded. Refer to Stent Deployment Procedure, section 4. Deploy Stent for directions on deploying the stent with the: Thumbwheel (10) Fast Track Deployment Lever (11) Indications for Use The LifeStent XL Biliary Stent System is intended for use in the palliation of malignant strictures (neoplasms) in the biliary tree. Contraindications Contraindications associated with the use of transhepatic biliary stents include: Stenting of a perforated duct where leakage from the duct could be aggravated by the prosthesis. Patients with uncorrected bleeding disorders. Patients with severe ascites. Patients with extensive hepatic metastases precluding a percutaneous transhepatic approach. Patients with impossibility of intraductal sounding. DO NOT expose the delivery system to organic solvents (e.g., alcohol). Persons with allergic reactions to nickel titanium (nitinol) alloy may suffer an allergic response to this implant. Stenting across a major bile duct branch could cause difficulties during future diagnostic or therapeutic procedures. The stent is not designed for repositioning or recapturing. The LifeStent XL Biliary Stent System is supplied sterile and is intended for single use only. DO NOT resterilize and/or reuse the device. Precautions The device is intended for use by physicians who have received appropriate training. The delivery system is not designed for use with power injection systems. Recrossing a partially or fully deployed stent with adjunct devices must be performed with caution. Prior to stent deployment, remove slack from the portion of the delivery system catheter held outside the patient. Warnings The safety and effectiveness of this device for use in the vascular system have not been established. DO NOT use the stent after the END of the month indicated by the Use By date specified on the package. DO NOT use if the temperature exposure indicator (i.e., square label found on the pouch) is black, as the unconstrained stent diameter may have been compromised. The temperature exposure indicator label should be grey and must be clearly visible on the pouch. DO NOT use if pouch is opened or damaged. DO NOT use with Ethiodol or Lipiodol contrast media. 2 Store in a cool, dark, dry place. Do not attempt to break, damage or disrupt the stent after placement. Adverse Reactions Potential complications associated with the use of transhepatic biliary stents may include, but are not limited to: Bile duct perforation Liver abscess Pancreatitis

Stent Size Selection Table: LifeStent XL Biliary Stent System Bile Duct Diameter Unconstrained Stent Inner Diameter 4.0 4.5 mm 5.0 mm 4.5 5.5 mm 6.0 mm 5.5 6.5 mm 7.0 mm Refer to product labeling for stent length. Parenchymal hemorrhage Sepsis / infection Sludge occlusion Stent migration Stent misplacement Stent obstruction secondary to tumor in-growth through the stent Tumor overgrowth at the stent ends Directions for Use Pre-Deployment Procedure 1. Inject Contrast Media Perform a percutaneous transhepatic cholangiogram using standard technique. 2. Evaluate and Mark Stricture Fluoroscopically evaluate and mark the stricture, observing the most distal level of the biliary stricture. 3. Select Stent Size Measure the length of the target stricture to identify the appropriate length of stent required. Ensure that the stent is long enough to permit the area proximal and distal of the tumor to be covered by the stent to inhibit tumor overgrowth at the stent ends. Identify the diameter of the target bile duct (proximal and distal to the stricture). To ensure secure placement, refer to the stent size selection table for proper sizing scheme (see page 3). 4. Prepare Stent Delivery System a) Open the box and remove the pouch containing the stent system. 3 b) Check the temperature exposure indicator label on the pouch to confirm that its grey background is clearly visible. See Warnings section. c) Carefully inspect the pouch for damage to the sterile barrier. Then, peel open the pouch and remove the elements containing the stent system. Extract the stent system from the tray and check the following: i) Verify that the shipping lock is still secure in the delivery system handle. ii) Examine the stent and delivery system device for any damage. If it is suspected that the sterility or performance of the device has been compromised, the device should not be used. d) Visually inspect the distal end of the delivery system catheter to ensure that the stent is contained within the sheath. Do not use if the stent is partially deployed. e) Flush the inner lumen of the device with saline prior to use. f) Wipe the usable length portion of the delivery system catheter with a gauze soaked with saline. Stent Deployment Procedure 1. Insert Introducer Sheath and Guidewire a) Gain access at the appropriate site utilizing a 6F (or larger) introducer sheath. b) Insert a guidewire of appropriate length (See table) and diameter across the stricture to be stented via the introducer sheath. Recommended Guidewire Length Table Catheter Recommended Working Length Guidewire Length 130 cm 300 cm 80 cm 260 cm

2. Dilate Stricture No predilation is generally performed with malignant strictures. However, if the physician deems that predilation is required, standard techniques may be used. While maintaining stricture access with a guidewire, remove the balloon catheter from the patient. Caution: During dilation, do not expand the balloon such that dissection complication or bleeding could occur. 3. Introduce Stent Delivery System a) Advance the device over the guidewire through the sheath introducer. Note: If resistance is met during delivery system introduction, the system should be withdrawn and another system should be used. Caution: Always use an introducer sheath for the implant procedure to protect both the liver tract and puncture site. A 6F (or larger) introducer sheath is recommended. b) Position the tip of the delivery system past the stricture site. c) Pull back the delivery system until the distal and proximal ends of the stent are in position so that they are distal and proximal to the target stricture. Note: The LifeStent XL Delivery System proximal radiopaque marker identifies the proximal end of the stent and can be used to position the proximal end of stent to the target stricture. d) Remove slack from the portion of the delivery system catheter held outside the patient. Caution: Any slack in the delivery system catheter (outside the patient) could result in inaccurate stent delivery. 4. Deploy Stent a) Verify that the distal and proximal stent ends are distal and proximal to the target stricture. b) Confirm that the introducer sheath is secure and will not move during deployment. c) Remove the shipping lock. d) To ensure the most accurate placement, firmly hold the black system stability sheath throughout deployment Note: Do NOT hold the silver stent delivery sheath at any time during deployment. DO NOT constrict the stent delivery sheath during stent deployment. e) Initiate stent deployment by rotating the thumbwheel in the direction of the arrows while holding the handle in a fixed position. Note: If excessive force is felt during stent deployment, do not force the stent system. Remove the stent system as possible, and replace with a new unit. f) While using fluoroscopy, maintain position of the distal and proximal stent ends relative to the target stricture site. Rotate thumbwheel (Fig. 3), watch for the distal stent end to begin expanding; separation of the distal stent end signals that the stent is deploying. Continue turning the thumbwheel until the distal end of the stent obtains a minimum of 1 cm of wall apposition. While maintaining a fixed handle position, rotate thumbwheel to obtain initial stent wall apposition of 1 cm minimum. Figure 3. Initial Thumbwheel Deployment 4 Note: The thumbwheel is designed to initially deploy the stent distal end a minimum of 1 cm. Final stent deployment is

achieved by using the deployment lever. g) With distal end of the stent apposing the duct, deployment continues with the following method (Fig. 4). While maintaining a fixed handle position, place your finger in front of the deployment slide and slide it from the distal to proximal end. Figure 4. Fast Track Deployment Lever Note: To ensure correctly deployed stent length, fluoroscopically monitor the distal stent end initially until wall apposition then monitor the delivery system proximal radiopaque marker relative to the proximal edge of the stricture site. h) Deployment of the stent is complete when the proximal stent end apposes the duct wall and the sheath radiopaque zone is proximal to the proximal end of the stent. i) Do not attempt to re-sheath catheter system prior to removal. 5. Post Stent Placement a) Remove the delivery system from the body. b) If additional stent-to-duct apposition is desired, select a balloon catheter that matches the size of the reference biliary duct, but that is not larger than the stent diameter itself. c) Remove the guidewire and introducer sheath from the body. d) Close entry wound as appropriate. e) Discard the stent delivery system, guidewire, and introducer sheath. Note: Physician experience and discretion will determine the appropriate drug regimen for each patient. 5 Magnetic Resonance Imaging (MRI) Compatibility Conditions for All Stents Non-clinical testing has demonstrated that the LifeStent XL Biliary Stent is MR Conditional for biliary placement. It can be scanned safely under the following conditions: Static magnetic field of 1.5-Tesla or 3-Tesla. Spatial gradient field of 2500 Gauss/cm or less. Maximum whole-body-averaged specific absorption rate (SAR) of 2 W/kg for 15 minutes of scanning per sequence. Normal mode operation of the MR system. 3.0 Tesla temperature Rise Temperature rises of stents were measured according to ASTM F2182-11a in a nonclinical configuration using a GE Signa HDX Whole Body active shield MR scanner using software version 14/LX/MR and a phantom designed to simulate human tissue. The phantom average SAR calculated using calorimetry was 2.7 W/kg. When the stent was placed in a worst-case location within the phantom, the maximal temperature rise was 2.4 C when the local SAR was scaled to 2 W/kg. 1.5 Tesla temperature Rise Temperature rises of stents were measured according to ASTM F2182-11a in a nonclinical configuration using a GE Signa whole body coil and a phantom designed to simulate human tissue. The phantom average SAR calculated using calorimetry was 2.3 W/kg. When the stent was placed in a worst-case location within the phantom, the maximal temperature rise was 3.2 C when the local SAR was scaled to 2 W/kg. Image Artifact MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the stent. Artifact tests were performed according to ASTM F2182-11a. Maximum

artifact extended 3 mm beyond the stent for the spin echo sequence and 10 mm for the gradient echo sequence. The lumen was obscured. Additional Information The LifeStent XL Biliary Stent has not been evaluated in MRI systems other than 1.5 or 3.0 Tesla. The heating effect in the MRI environment for overlapped or fractured stents is not known. The presence of other implants or the health state of the patient may require reduction of the MRI limits listed above. How Supplied The LifeStent XL Biliary Stent System is supplied sterile (by ethylene oxide gas) and is intended for SINGLE USE ONLY. 6

Symbols used on labeling Keep away from sunlight Keep dry The Green Dot Recyclable MR Conditional 7

LifeStent XL Biliary Stent System Bard and LifeStent are trademarks and/or registered trademarks of C. R. Bard, Inc. All other trademarks are the property of their respective owners. Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. Copyright 2013 C. R. Bard, Inc. All Rights Reserved Distributed in the USA by: Bard Peripheral Vascular, Inc. Subsidiary of C. R. Bard, Inc. 1625 West 3 rd Street Tempe, AZ 85281 USA TEL: 1-480-894-9515 1-800-321-4254 FAX: 1-480-966-7062 1-800-440-5376 www.bardpv.com B05688 Rev.2/07-13 8