ECOplus Solar Cylinder



Similar documents
PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Technical data. Danfoss DHP-A

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

Solar Hot Water Heaters

Session 2: Hot Water Supply

STATIONARY WATER HEATERS

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Zenith Solar thermal 4.5m pump station Installation manual

HEAVY DUTY STORAGE GAS

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating!

HYBRID HEAT PUMPS. Switch over to more efficiency, even in old buildings. Air/water system for heating HBW series. Quality with systems. max.

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Type 3353 Angle Seat Valve

Self-operated Temperature Regulators Temperature Regulator Type 1u

1 DESCRIPTION OF THE APPLIANCE

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Thermo Siphon Solar Systems

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

SERVICE MANUAL Order No.WH0911S001V0

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Professional Report. Map section. Location of the system. Valkkinen Longitude: Latitude: Elevation: 89 m

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Machine nozzle with needle shut-off type HP pneumatically or hydraulically controlled

INSTRUCTIONS FOR USE, MAINTENANCE AND INSTALLATION OF THE

Operators manual Basic water heater

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

SunMaxx Solar Filling Station Operating Instructions

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Natural geothermal energy.

3/2-way Solenoid Valve, direct-acting, NC or NO

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

Overheating limit control

RPV - RP - RA air handling units

Technical Data Manual Model Nos. and pricing: see Price List

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Electric Flow Boiler

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

API Flanged Safety Relief Valves Series 526 CATALOG

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Heat Recovery based on Exhaust Air

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

Conlift1, Conlift2, Conlift2 ph+

Vacuum Tube Solar Water heater Non-pressure. User manual

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Solar hot water systems that give energy efficiency a whole new meaning

CRN A-F-G-E-HQQE 3x400D 50 HZ

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

HERZ-Thermal Actuators

Vacuum drying oven for non-flammable solvents

Versati Air to Water Heat Pump

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

ASME Packaged Indirect Fired Water Heater

Machine bolt shut-off nozzle type BHP pneumatically or hydraulically controlled

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80

Specifications for Volkswagen Industrial Engine

MARCH 2007 EDITION WATER HEATERS GENERAL CATALOGUE

Laddomat Charging unit


DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

Refrigeration Compressed Air Dryer Buran Ultrapulse

ETC -SV. Class 0 oil-free compressed air through catalysis

3/2-way pneumatic cartridge solenoid valve

solarplus solar systems general features

Solar Thermal Systems

ELECTRIC CENTRAL HEATING FLOW BOILER

High-efficient gas boiler CompactGas

ECOCIAT. Domestic hot water heat recovery unit

CRAC Precision climate control units for data centres

Radial piston pumps type R and RG

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Material test chamber with mechanical convection

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Air Conditioner Water Heater Model ACWH18

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Hydraulic Control Solutions

Transformer oil cooler ALFA A02

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Stove-boiler for solid fuels KW Directions for use and assembling

Energy Efficiency in Buildings

How To Use An Akua Magnetic Lime Scale Preventing Device

Light Duty Commercial Electric Water Heater

PRESSURE REDUCING VALVES

Electric Heat Tracing INSTALLATION PROCEDURES

Electric Rotary Actuator - On/Off or programmable control actuator

4/2-Way Pneumatic Solenoid Valve

YUTAKI S. Domestic Heating

Volkswagen Golf > VW Rabbit GTI 2006->

Heating, air-conditioning, cooling

Transcription:

TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes safely from the hot storage tank water. This reduces heat losses at the pipe connections by up to 50%. Optional Mounting Kit for Solar Pumping Station 6 for minimized piping effort - time and space saving and neat appearance Minimal Heat Losses due to convection brakes in the pipe connections, as well as due to close-fitting, CFC-free 100-mm thick jacket insulation made from soft PU foam as well as the 150-mm thick and close fitting lid insulation and 50-mm thick floor insulation with robust polystyrene shell. Double Corrosion Protection due to durable high-quality enamel coating and magnesium protection anode. Quick Assembly by flat-sealing screw connections with combi-fittings, sensor terminal block, removable heat insulation with hook closure; horizontal attachment of the connection pipes made possible by CONVECTROL II. Stable Thermal Stratification due to slim, columnar design and stabilized cold water inlet and hot water outlet flows. Heat Exchanger Resistant to Lime Buildup made from plain pipe for solar and heating circuit with optimized installation design, generously dimensioned. High Quality due to the use of high-grade and environmentally friendly materials. Manufactured and inspected in accordance with DIN 4753. Options for circuit line and electrical immersion heater, cleaning flange. Installation example with 6 cylinder mounting kit Figure 1 The solar cylinder great quality at a great price available sizes are 300, 400, 500, and 750 liters. Solar Thermal / Solar Cylinder EN--Solar-Cylinder_TI-0801-11204200 1

Technical Data D d K H G M E L I C B A J Figure 2 Sectional view of the solar cylinder with dimensions. Accessories connection kit Kombi STANDARD with combi fittings Art. No. 13900055 connection kit Kombi CONVECTROL with combi fittings Art. No. 139 000 56 6 cylinder mounting kit, order no. 150 302 01 Cylinder height adjustment unit, Art. No. 139 000 16 5 combination fitting sets 5/4 x22", 1 combination fitting set 1"x22", 1 plug 1 ½" and cap ¾" and manual bleeder ½" 5 combination fitting sets 5/4"x22", 1 combination fitting set 1 ½", 1 plug 1 ½" and cap ¾", 5 convection brakes and manual bleeder ½" rigid cylinder pipes, 1 ¼" flat sealing To align tank in case of uneven floor Cylinder safety subassembly, Art. No. 130 100 56 Complete safety subassembly acc. to DIN 1988 CORREX-UP impressed current anode, Art. No. 130 101 26 Electrical immersion heater, 1,5 kw ( 139 001 45), 3 kw (139 001 42), 6 kw (139 001 43) Service water mixing valve BM, Art. No. 100 89 Service water mixing valve BM, Art. No. 150 300 75 Assembly tool, Art. No. 130 002 39 Maintenance-free corrosion protection, 230 V 1,5 kw/230 V; 3 kw/230/400; 6 kw/400; immersion depth /mm: 260/360/550 35 to 55 C, 22-mm soldered union screw connection 35 to 55 C, ¾"-mm threaded union screw connection Aids in the closure of the hook closure, length 200 mm 2 EN--Solar-Cylinder_TI-0801-11204200

Feature Unit 300 l 400 l 500 l 750 l Article No. 130 140 01 130 140 11 130 140 21 130 140 31 Total capacity in liter 313 391 490 755 Aux. heating volume share in litre 135 165 220 310 Permiss. working overpressure in bar 10 Max. temperature in C 95 Usable hot water volume with indicated aux. heating temp. in liter at 50 C 1 138 162 215 260 2 Coefficient of performance N L / assoc. boiler output 1 per kw 1.6 / 10 2.4 / 12.5 3.5 / 13.5 5.7 / 17.5 Thermal insulation rating Jacket insulation 100 mm PU soft foam with polystyrene shell Lid 150 mm and floor 50 mm PU soft foam Heat loss rate acc. to DIN ENV 12977-3 34 in W/K 2.59 2.88 3.29 4.38 Anode, 1 1/4" IT 6 K Magnesium protection anode CORREX-UP CW connection / HW connection, 1" OT / 5/4" 6 mm A/G 110 / 1370 120 / 1440 130 / 1541 157 / 1763 Circulation, R (con.) 3/4" OT x 30mm in mm E 1050 1115 1120 1373 Cleaning flange (outer diameter 180 mm) in mm J 280 295 300 447 Height with insulation in mm H 1695 1775 1885 2132 Tilted dimension, without insulation in mm 1600 1680 1800 2050 Diameter (without/with insulation) in mm d/d 550 / 750 600 / 800 650 / 850 750 / 950 Weight without insulation in kg 130 170 230 295 Solar Circuit Heat Exchanger 5 Area (m²) / volume (l) 1.4 / 8.5 1.7 / 10.0 1.9 / 12.0 2.6 / 15.0 Pressure loss at 40 C/h mbar / volume flow in l/h 2 / 200 3 /280 5 / 360 7 / 400 Permiss. working overpressure in bar 16 Inlet/Return f. solar circuit HT, 5/4" OT 6 mm C/B 675 /205 690 / 220 705 / 225 980 / 280 Recommended collector area in m² 4.5 8 5 10 6 14 7 20 Aux. Heating Heat Exchanger 5 Area m² / capacity 1.0 / 6.0 1.2 / 7.0 1.3 / 8.0 1.7 / 10.0 Pressure loss at 60 C/h mbar / volume flow in l/h 4 / 450 6 / 550 11 / 700 26 / 1000 Permiss. working overpressure in bar 16 Inlet/Return f. aux. heating circuit HT, 5/4" OT 6 mm L/M 930 / 1270 1000 / 1340 1020 /1440 1223 / 1663 Constant output 1 in kw 10 13 14 18 Electrical Aux. Heating (Optional) Connection, 1 1/2" IT 6 mm I 803 845 863 1092 IT = Inner threading; OT = Outer threading 1) Storage tank with 45 C tappable water quantity if the aux. heating section was heated to the indicated aux. heating temperature (cold water temperature 10 C), values acc. to test report by ITW Stuttgart based on DIN ENV 12977-3 2) Calculated based on DIN EN 12977 3) Acc. to test report by ITW Stuttgart based on DIN ENV 12977-3 4) Calculated based on DIN EN 12977 5) Heat exchanger acc. to DIN 1988 T2 model C 6) Pipe thread DIN ISO 228-1 (cyl.), flat-sealing EN--Solar-Cylinder_TI-0801-11204200 3

Convection Brake CONVECTROL II Using the CONVECTROL II convection brakes make it possible to lower heat losses of the solar cylinder by up to 50 % per pipe connection. The patented design of the barriers separates the water cooled in the connection pipes from the hot content of the cylinder. Annual cylinder heat losses are thus reduced by 10 % to 20 %. Figure 3 Convection brake CONVECTROL II Without Convection Brake If the solar cylinder is in standby mode, hot water from the storage tank enters the upper section of the connection pipe and flows along the pipe. While in this pipe, the water cools down to the ambient temperature and drops into the lower pipe section due to the increasing density. In the lower pipe section, the cold water returns to the cylinder (one-pipe convection). Energy is continuously withdrawn from the cylinder. 60 C Without convection brake High heat loss Solar cylinder Soft foam insulation With Convection Brake The inlet opening at the pipe sleeve positioned high prevents the water cooled in the connection pipe from flowing back to the solar cylinder. The upper barrier prevents the hot water from the cylinder from flowing into the connection pipe. The thermal conduction via the pipe fitting is blocked between the end faces with the flat seals. The heat losses of the pipe connection are reduced by up to 50 %. 60 C Konvektionsbremse With convection brake Pipe insulation Low heat loss Figure 4 Heat losses at cylinder pipe connections with and without CONVECTROL II convection brake. Technical Data CONVECTROL II Outer diameter Length Ø38.5 mm/27 mm f. 5/4" OT 30 mm Pressure loss p [mbar] 35,0 Solar fluid (40% DC20, 40 C) 30,0 Material Thermal stability acc. to ISO 75, Version A+B Continuous operation temperature PA 6-3-T, 40 % fiberglass reinforced > 230 C max. 95 C Temporary max. temperature max. 140 C 25,0 20,0 15,0 10,0 5,0 Water (20 C) Tensile e-modulus ISO 527 11000 MPa Creep modulus (1000h) 5200 MPa Coefficient of linear expansion 0.222x10-4 K -1 Permits and certificates: DVGW-DZW, KTW, BgVV 0,0 0 200 400 600 800 1000 Volume flow V [l/h] Figure 5 Pressure loss of the CONVECTROL II convection brake with passage of water and solar fluid. 4 EN--Solar-Cylinder_TI-0801-11204200

: Solar circuit pump P2 : Cylinder charge pump P3 : Heating circuit pump : Service water mixing valve Solar controller Heating circuit P3 Oil or gas heating boiler P2 Figure 6 Solar installation for hot water preparation. One cylinder system with solar hot water cylinder and auxiliary heating with oil or gas boiler. The solar controller operates the solar circuit pump speed-controlled depending on solar irradiation and storage tank temperature. This results in the continuous operation of the system and reduces the electricity consumption of the pump (Principle representation, see fig. 2 for real position of connections). : Solar circuit pump V1 : 3-way switching valve (hot water-auxiliary heating or heating operation) : Service water mixing valve Solar controller Gas water heater Heating circuit M V1 Figure 7 Solar installation for hot water preparation. A one-cylinder system with solar hot water cylinder and a gas-fired wall-mounted heating boiler. Switching between heating mode and hot water auxiliary heating is carried out by the 3-way valve installed in the wall boiler inlet flow pipe. The heater controller controls the switching operation. The solar controller operates the solar circuit pump speed-controlled depending on solar irradiation intensity. This results in the continuous operation of the system and reduces the electricity consumption of the solar pump (Principle representation, see fig. 2 for real position of connections). EN--Solar-Cylinder_TI-0801-11204200 5

: Solar circuit pump P2 : Cylinder charge pump P3 : Heating circuit pump V1 : 3-way switching valve (cylinder charging) : Service water mixing valve Solar controller Heating circuit P3 Oil or gas heating boiler P2 A M AB B V1 Figure 8 Solar Installation for hot water preparation. Series switching of solar cylinder and monovalent hot cylinder tank. The solar energy is distributed optimally to both cylinders by the controller. The solar cylinder is integrated in the form of a draw-off cylinder and is heated first by the solar installation. The auxiliary heating carried out with the oil or gas boiler also takes place in the solar cylinder. The monovalent cylinder (only one heat exchanger) serves as preheating tank. This type of layout can be used with an existing hot water cylinder and is characterized by reduced storage tank and system losses (Principle representation, see fig. 2 for real position of connections). Solar controller : Solar circuit pump : Service water mixing valve Electrical immersion heater Figure 9 Solar installation for hot water preparation. One-cylinder system with solar hot water cylinder and auxiliary heating with electrical immersion heater. If solar charging is insufficient, the immersion heater reheats the upper third of the solar cylinder. The temperature of the auxiliary heating can be adjusted at the thermostats installed the one immersion heater. The solar controller SunGo operates the solar circuit pump speed-controlled depending on solar irradiation and storage tank temperature. This results in the continuous operation of the system and reduces the electricity consumption of the pump (Principle representation, see fig. 2 for real position of connections). Subject to modifications, errors excepted. Wagner & Co, 2008 www.wagner-solar.com 6 WAGNER & CO Zimmermannstraße 12 D-35091 Cölbe/Marburg +49 6421 80 07-0 Fax 80 07-22