1 Release R.2.0 Uk Installation User and Service Manual
2 your installer
3 Warning Read this manual carefully before first using the water heater. Failure to read this manual and to follow the instructions in this manual may lead to accidents, personal injury, and damage to the appliance. Copyright Trademarks Liability More information Copyright 2004 State Water Heaters All rights reserved. Nothing from this publication may be copied, reproduced and/or published by means of printing, photocopying or by whatsoever means, without the prior written approval of State Water Heaters. State Water Heaters reserves the right to modify specifications stated in this manual. Any brand names mentioned in this manual are registered trademarks of their respective owners. State Water Heaters accepts no liability for claims from third parties arising from improper use other than that stated in this manual and in accordance with the General Conditions registered at the Eindhoven Chamber of Commerce. Refer further to the General Conditions. These are available on request, and without charge. Although considerable care has been taken to ensure a correct and suitably comprehensive description of all relevant components, the manual may nonetheless contain errors and inaccuracies. Should you detect any errors or inaccuracies in the manual, we would be grateful to receive notification. This helps us to further improve our documentation. If you have any comments or queries concerning any aspect related to the appliance, then please do not hesitate to contact State Water Heaters. Aquaheat State Sales Orchard House, Commercial Road Southampton SO15 1GG Tel.: Fax: [email protected] In the event of problems with connecting to the gas, electricity or water supply, please contact your installation s supplier/installer. Release R.2.0 Uk 3
4 4 Instruction Manual
5 gis Table of contents 1 Introduction About the appliance What to do if you smell gas Regulations Target groups Maintenance Forms of notation Overview of this document Functioning of the appliance Introduction Functional description of the appliance The appliance s heating cycle Protection for the appliance Water temperature protection Flue gas backflow safeguard Ionisation rod Safety of the installation Unvented installation Vented installation T&P valve Installation Introduction Packaging Environmental conditions Working clearances Humidity and ambient temperature Maximum floor loading Water composition Technical specifications Installation diagram Water connections, Unvented Cold water side Shunt pipe Hot water side Drain valve Circulation pipe Water connections, Vented Cold water side Shunt pipe Hot water side Circulation pipe Gas connection Flue gas discharge Introduction Fitting the draught diverter Flue gas thermostat assembly Release R.2.0 Uk 5
6 gis 3.10 Electrical connection Introduction Preparation Mains voltage Week timer circuit Connecting extra error signal ( Alarm OUT ) Checking the supply pressure and burner pressure Conversion to a different gas category Introduction Conversion to a different gas through Conversion to a different gas category Filling and draining Introduction Filling the appliance Filling unvented installations Filling vented installations Draining the appliance Draining unvented installations Draining vented installations Operating Introduction Control panel Explanation of the icons I/0/II switch Control thermostat Burner control reset button Week timer circuit Flue gas backflow safeguard reset button Status of the appliance Introduction Operating modes Power Anode Status Error conditions Starting up and shutting down Introduction Starting up Shutting down Shut the appliance down for a brief period ( OFF mode ) Disconnect the appliance from the mains Shut the appliance down for a longer period The appliance s heating cycle Troubleshooting Introduction Troubleshooting table for general errors Troubleshooting table no hot water Troubleshooting table insufficient hot water Maintenance Introduction Instruction Manual
7 gis 9.2 Preparation for maintenance Water-side maintenance Introduction Checking the anodes Descaling and cleaning the tank Gas-side maintenance Introduction Cleaning the burners Cleaning the orifices Checking the flue baffles Finalising maintenance Warranty (Certificate) General warranty Tank warranty Installation and conditions of use Exclusions Scope of the warranty Claims Limitation of liability State A Appendices A.1 Introduction A.2 Electrical diagram A.2.1 Electrical diagram LP A.2.2 Electrical diagram IX Index Release R.2.0 Uk 7
8 gis 8 Instruction Manual
9 gis 1 Introduction About the appliance 1.1 About the appliance This manual describes how to install, service and use the appliance. The appliance is a gas-fired open water heater without a fan. The appliance is fitted with a flue gas backflow safeguard and falls into the appliance category B11BS. This information is located on the appliance s identification plate. The information in this manual is applicable to types : , , , , , , , The manner of construction and features of the appliance are in conformance with the European standard for gas-fired storage water heaters for the production of domestic hot water (ES 89). The appliances are therefore compliant with the European Directive for Gas Appliances, and have the right to bear the CE mark Warning Read this manual carefully before starting up the water heater. Failure to read the manual and to follow the printed instructions may lead to personal injury and damage to the appliance. 1.2 What to do if you smell gas Warning Whenever there is a smell of gas: No naked flames! No smoking! Avoid causing sparks! Do not use any electrical equipment or switch, i.e. no telephones, plugs or bells! Shut off the mains gas supply! Open windows and doors! Warn occupants and leave the building! After leaving the building, alert the gas distribution company or installer. 1.3 Regulations As the (end) user, installer or service and maintenance engineer, you must ensure that the entire installation complies, as a minimum, with the official local: building regulations; energy supplier s directives for existing gas installations; directives and technical guidelines for natural gas installations; safety requirements for low-voltage installations; regulations governing the supply of drinking water; regulations governing ventilation in buildings; regulations governing the supply of air for combustion; regulations governing the discharge of products of combustion; requirements for installations that consume gas; regulations governing indoor waste water disposal; regulations imposed by fire service, power companies and municipality; Release R.2.0 Uk 9
10 1 Introduction gis Furthermore, the installation must comply with the manufacturer s instructions. n Note Later amendments and/or additions to all regulations, requirements and guidelines published on or prior to the moment of installing, will apply to the installation. 1.4 Target groups The three target groups for this manual are: (end) users; installers; service and maintenance engineers. Symbols on each page indicate the target groups for whom the information is intended. See Table 1.1. Table 1.1 Target group symbols Symbol g (End) Target group user i installer s Service and maintenance engineer 1.5 Maintenance A service should be carried out at least once a year, both on the water side and on the gas side. Maintenance frequency depends, among other things, on the water quality, the average burning time per day and the set water temperature. n Note To determine the correct maintenance frequency, it is recommended to arrange for the service and maintenance engineer to check the appliance on both the water and gas side, three months after installation. Based on this check, the best maintenance frequency can be determined. n Note Regular maintenance extends the service life of the appliance. Both the end user and the service and maintenance engineer are responsible for regular maintenance. They will need to establish clear agreements on this. n Note If the appliance is not regularly maintained, the warranty will become void. 10 Instruction Manual
11 gis Forms of notation 1.6 Forms of notation The following notation is used in this manual: n Note Important information c Caution Ignoring this information can lead to the appliance being damaged. Warning Failure to carefully read this information may lead to danger of personal injury, and serious damage to the appliance. 1.7 Overview of this document Table 1.2 provides an overview of the contents of this document. Table 1.2 Contents of document Chapter Target groups Description 2 Functioning of the appliance 3 Installation 4 Filling and draining 5 Operating 6 Status of the appliance 7 Starting up and shutting down 8 Troubleshooting 9 Maintenance 10 Warranty (Certificate) gis is gis gis gis gis gis s gis This chapter describes how the appliance functions. This chapter describes the installation activity to be completed before you actually start up the appliance. Instructions are also provided for the installation and/or service and maintenance engineer on converting the appliance to other types of gas. This chapter describes how to fill and drain the appliance. This chapter describes the appliance s control panel, and how to use it. This chapter describes the status (mode or condition) that the appliance may have, and possible actions to take. This chapter describes how to start up the appliance, and how to shut it down for a brief or long period of time. The general heating cycle of the appliance is also described. This chapter is mainly intended for the installer and the service and maintenance engineer. It describes appliance errors. These errors are indicated on the display. A troubleshooting table of possible causes and solutions is provided. End users may also refer to this chapter for additional information about the appliance. This chapter sets out the maintenance tasks to be carried out during a service. This chapter states the warranty terms and conditions. Release R.2.0 Uk 11
12 1 Introduction gis 12 Instruction Manual
13 gis 2 Functioning of the appliance Introduction 2.1 Introduction Topics covered in this chapter: Functional description of the appliance; The appliance s heating cycle; Protection for the appliance; Safety of the installation. Release R.2.0 Uk 13
14 2 2.2 Functional description of the appliance Legend a flue gas discharge b draught diverter c anodes d flue tubes e flue baffles f PU-isolation g tank h cleaning opening i drain valve j combustion chamber k radiation shield/condensation tray l gas control m flue gas thermostat sensor n flue gas thermostat o hot water outlet p safety thermostat sensor q high-limit thermostat sensor r control panel s control thermostat t burner control u high-limit thermostat v frost thermostat w safety thermostat x control thermostat sensor y frost thermostat sensor z cold water inlet A glow igniter B ionisation rod C bar burner/ burner tray Functioning of the appliance Figure 2.1 shows a cut-away view of the appliance. a b c d e f g h i j k l Figure 2.1 Cross-section of the appliance gis m n o p q r s t u v w x y z A B C IMD-0143 In this appliance, the cold water enters the bottom of the tank via the cold water inlet z. The heat of combustion is transferred to the water through the combustion chamber j and flue tubes d. The heated tap water leaves the tank via the hot water outlet o. Once the appliance is completely filled with water, it remains constantly under water supply pressure. As hot water from the appliance is consumed, it is continuously replenished with cold water. 14 Instruction Manual
15 gis The appliance s heating cycle The gas required for combustion flows into the manifold via the gas control l. Orifices are located within the manifold. Via these orifices, the gas enters the bar burners C. The bar burners together form the burner tray. As the gas is injected into the bar burners, the primary air required for combustion is also drawn in (1). Additional air is drawn through the openings in the burner tray. The glow igniter A ensures the ignition of the gas/air mixture. The flue gases generated by this combustion are led through the flue tubes d. There are flue baffles e fitted inside the flue tubes. These slow down the flue gas exhaust, improving the heat transfer efficiency. The flue gases leave the appliance via the draught diverter b. A radiation shield/condensation tray k is mounted below the burner tray. This prevents overheating of the floor surface under the appliance and serves as a collection tray for condensation water. The PU-isolation f prevents heat loss. The inside of the tank is enamelled to protect against corrosion. The anodes c provide additional protection. The Hydro Cannon also protects the bottom of the tank from scale and lime buildup. 2.3 The appliance s heating cycle 2.4 Protection for the appliance The entire appliance is controlled by the burner control t and the control thermostat s or frost thermostat v. The control thermostat and frost thermostat both independently measure the water temperature (T water ). The appliance s heating cycle is activated as soon as T water falls below the specified threshold value (T set ). The value for T set depends on the status chosen for the appliance, see paragraph 6.2 Operating modes. If the appliance is in the OFF mode (frost protection), then this value is determined by the frost thermostat (threshold value = 20 C). If the appliance is in the ON mode, then the threshold value is selectable via the control thermostat (±40 C - ±70 C). As soon as T water falls below T set, the relevant thermostat (control or frost) will close, and the burner control will register a heat demand. The gas control l will open, and the gas will mix with the air it draws in. This mixture is ignited by the glow igniter A and the water becomes heated. A soon as T water exceeds T set, the thermostat will open once more. The heat demand will cease, and the burner control will stop the heating cycle. The thermostats have a certain margin both when closing and opening. We refer to this margin as the hysteresis. The hysteresis cannot be adjusted. The burner control monitors the water temperature by means of thermostats, and ensures a safe combustion. This is achieved by: the Water temperature protection; the Flue gas backflow safeguard; the Ionisation rod. 1. The narrow opening in the orifices accelerates the gas flow. This causes a partial vacuum. The effect of this partial vacuum is to draw the air into the flow (the Venturi effect). Release R.2.0 Uk 15
16 2 Functioning of the appliance gis Table 2.1 Temperature protection Water temperature protection By means of the frost, high-limit and safety thermostats, the burner control monitors three temperatures related to safety. See Table 2.1. Protection Frost thermostat High-limit thermostat Safety thermostat Description If the frost thermostat sensor y detects a temperature of 20 C or lower, the appliance s heating cycle will start. See paragraph 2.3 The appliance s heating cycle. If the high-limit thermostat sensor q detects a temperature greater than 84 C, the high-limit thermostat will open. The heat demand will be stopped, and the burner control will stop the heating cycle until the high-limit thermostat closes again. At that moment, the burner control resets the appliance, and the heating cycle resumes. The high-limit safeguard serves to prevent overheating and/or excessive formation of scale in the appliance. If the safety thermostat sensor p detects a temperature greater than 93 C, the safety thermostat will open. The heat demand will be ended, and the burner control immediately stops the heating cycle. A lockout error will occur in the burner control. This must be manually reset, before the appliance can be put back into operation Flue gas backflow safeguard The flue gasses are directed to the outside via the draught diverter b and the flue gas discharge a. To prevent the flue gases from flowing back into the boiler room, the discharge ducting is monitored by a feature called the Thermal Reflux Safeguard (T.R.S.). This uses a flue gas thermostat sensor m with flue gas thermostat n which are located in the draught diverter. Under normal circumstances this sensor will register the ambient temperature. However, if the chimney is not drawing sufficiently (for example, due to a blockage in the chimney), the flue gases will reflux and flow back past the flue gas thermostat sensor. The sensor will then detect an excessive temperature and the flue gas thermostat will open. The heat demand will be ended, and the burner control immediately stops the heating cycle. The flue gas thermostat will also lock out. This must be manually reset, before the appliance can be put back into operation Ionisation rod To prevent gas flowing when there is no combustion, an ionisation rod B is fitted. The burner control uses this rod for flame detection, by means of ionisation detection. The burner control acts immediately, as soon as it detects that gas is flowing, but there is no flame. 2.5 Safety of the installation In addition to the standard safety monitoring of the appliance, the appliance must also be protected by an expansion vessel, pressure overflow valve, nonreturn valve and a T&P valve. Use of an expansion vessel, a pressure relief valve and/or a pressure reducing valve depends on the type of installation: unvented or vented Unvented installation With an unvented installation, a pressure relief valve and expansion vessel prevent excessive pressure in the tank. This prevents damage being caused to the enamelled coating (in the appliance) or to the tank. A non-return valve prevents excessive pressure in the water supply system. This valve also 16 Instruction Manual
17 gis Safety of the installation prevents water from flowing backwards from the tank into the cold water supply system. The pressure reducing valve protects the installation against an excessively high water supply pressure (> 8 bar). These components are fitted to the cold water pipe. See paragraph Cold water side Vented installation With a vented installation, excess pressure is taken up by the open water reservoir. The level of the water reservoir determines the maximum working pressure in the tank, which may not exceed 8 bar. The installation must also be fitted with an overflow from the hot water pipe, which discharges into the water reservoir. See paragraph Hot water side T&P valve A T&P valve is only mandatory in an unvented installation. However, State also recommends the use of a T&P valve in vented installations. A T&P valve monitors the pressure in the tank, and the water temperature at the top of the tank. If the pressure in the tank becomes excessive (>10 bar) or the water temperature is too high (>97 C), the valve will open. The hot water will immediately flow out of the tank. Because the appliance is under water supply pressure, cold water will automatically flow into the tank. The valve remains open until the unsafe situation has been averted. A connecting point for a T&P valve is standard on the appliance. See paragraph Hot water side. Release R.2.0 Uk 17
18 2 Functioning of the appliance gis 18 Instruction Manual
19 is 3 Installation Introduction Warning The installation should be carried out by an approved installer in compliance with the general and local regulations imposed by the gas, water and power supply companies and the fire service. The appliance may only be installed in a room which complies with the requirements stated in national and local ventilation regulations. Refer also to paragraph 1.3 Regulations. 3.1 Introduction This chapter describes the installation activities to be carried out before the appliance may be started up, namely: Packaging; Environmental conditions; Technical specifications; Water connections, Unvented; Water connections, Vented; Gas connection; Flue gas discharge; Electrical connection; Checking the supply pressure and burner pressure; Conversion to a different gas category; n Note Starting up the appliance is described in chapter 7 Starting up and shutting down. Figure 3.1 shows a front view of the appliance. Release R.2.0 Uk 19
20 3 Installation is IMD-0145 Figure 3.1 Plan and elevation of the appliance 20 Instruction Manual
21 is Packaging 3.2 Packaging To avoid damaging the appliance, remove the packaging carefully. We recommend unpacking the appliance at or near its intended location. c Caution The appliance may only be manoeuvred in an upright position. Take care that the appliance is not damaged after unpacking. 3.3 Environmental conditions c Caution The appliance may not be used in rooms where chemical substances are stored or used due to the risk of explosion, and corrosion to the appliance. Some propellants, bleaching agents, degreasing agents and so on, disperse vapours which are explosive and/or which cause accelerated corrosion. If the appliance is used in a room in which such substances are present, the warranty will be void. -appliances are open appliances, and may only be placed in an open boiler room. They fall under category B11BS Working clearances For access to the appliance it is recommended that the following clearances are observed (see Figure 3.1): AA: around the appliance s control column and cleaning openings: 100 cm. BB: around the appliance itself: 50 cm. Above the appliance (room to replace the anodes): cm if using fixed anodes, or - 50 cm if using flexible anodes. If the available clearance is less than 100 cm, flexible magnesium anodes may be ordered from State Water Heaters. n Note When installing the appliance, be aware that any leakage from the tank and/ or connections can cause damage to the immediate environment or floors below the level of the boiler room. If this is the case, then the appliance should be installed above a wastewater drain or in a suitable metal leak tray. The leak tray must have an appropriate wastewater drain and must be at least 5 cm deep with a length and width at least 5 cm greater than the diameter of the appliance Humidity and ambient temperature The boiler room must be frost-free, or be protected against frost. Table 3.1 shows the environmental conditions that must be adhered to, for correct functioning of the electronics present in the appliance to be guaranteed. Table 3.1 Humidity and ambient temperature specifications Humidity and ambient temperature Humidity max. 93% RH at +25 C Ambient temperature Functional: 0 t 60 C Release R.2.0 Uk 21
22 3 Installation is Maximum floor loading Table 3.2 Weight specifications related to maximum floor loading Weight of the appliance filled with water In connection with the appliance s weight, take account of the maximum floor loading, see Table kg 523 kg 525 kg 594 kg 597 kg 540 kg 531 kg Water composition The appliance is intended for heating drinking water. The drinking water must comply with the regulations governing drinking water for human consumption. Table 3.3 shows these requirements. Table 3.3 Water specifications Water composition Hardness (alkaline earth ions) Conductivity > 1.00 mmol/l: German hardness > 5.6 dh French hardness > 10.0 fh British hardness > 7.0 eh > 125 µs/cm Acidity (ph value) 7.0 < ph value < 9.5 n Note If the water specifications deviate from those stated in Table 3.3, then the tank protection cannot be guaranteed. See also chapter 10 Warranty (Certificate). 3.4 Technical specifications The appliance is supplied without accessories. Check the dimensions and other specifications for the accessories to be used, based on Figure 3.1 and tables Table 3.4 through Table 3.7. Table 3.4 Dimensions Dimension Description A. Height including draught diverter (mm) B. Height excluding draught diverter (mm) D. Diameter of the appliance (mm) F. Width including control column (mm) G. Flue gas outlet diameter (mm)? K. Height of gas supply (mm) M. Height of cold water supply (mm) N. Height of hot water outlet (mm) Instruction Manual
23 is Technical specifications Table 3.4 Dimensions Dimension Description P. Height of the cleaning opening centre (mm) R. Height of the drain valve centre (mm) S. Height of the T&P plug centre (mm) Cold water supply (external) R 1½ 2. Hot water outlet connection (internal) Rp 1½ 3. Gas control connection (internal) Rp ¾ Rp 1 4. Tank drain valve connection (internal) Rp 1½ 5. T&P valve connection (internal) 1-14 NPT 6. Dimensions of the cleaning and inspection opening (mm) Ø 100 Table 3.5 Data on gas categories, appliance category II2H3+ Description Unit Data natural gas, gas category 2H Diameter of orifice mm Burner pressure control - Yes Yes Yes Yes Yes Yes Yes Yes G20 Nominal load (Upper Value) kw Pre-pressure mbar Burner pressure (1) mbar Gas consumption (2) m³/h Warm-up time dt = 44 K min Data on LP gas, gas category 3+ Diameter of orifice mm Heating up time min G30 (butane) Nominal load kw Supply pressure mbar Burner pressure (1) mbar Gas consumption (2) kg/h Release R.2.0 Uk 23
24 3 Installation is Table 3.5 Data on gas categories, appliance category II2H3+ (Continued) Description Unit G31 (propane) Nominal load (Upper Value). kw Supply pressure mbar Burner pressure (1 mbar Gas consumption (2) kg/h If using a flat sealing plate or high-low control program, instead of a burner pressure control, it is assumed that the burner pressure is equal to the pre-pressure. In practice however the burner pressure will be lower, 2. Based on mbar and 15 C Table 3.6 Data general Description Unit Capacity litres Number of bar burners/ orifices Number of flue tubes/flue baffles Empty weight kg Number of anodes Maximum working pressure bar Table 3.7 Data electrical DESCRIPTION Unit All models Electrical power consumption W 30 Supply voltage VAC 230 (-15% +10%) Mains frequency Hz 50 (±1 Hz) 3.5 Installation diagram Figure 3.2 shows the water and gas connection diagrams for unvented and vented installations. The following paragraphs, describing the connections in detail, make reference to these diagrams 24 Instruction Manual
25 is Installation diagram Legend a pressure-reducing valve (obligatory) b expansion vessel (obligatory) c T&P valve (obligatory) d stop valve (recommended) e non-return valve (obligatory) f circulation pump (optional) g drain valve h gas valve (obligatory) i stop valve (obligatory) j temperature gauge (recommended) k shunt pump (optional) l draught diverter m hot water draw-off points n pressure relief valve (obligatory) o water cistern p float valve q 3-way aeration valve (recommended) r overflow pipe a cold water supply b hot water outlet c circulation pipe d gas supply e flue gas outlet UNVENTED VENTED 13 IMD-0146 A IMD-0147 Figure 3.2 Installation diagrams Release R.2.0 Uk 25
26 3 Installation is 3.6 Water connections, Unvented Cold water side See a in Figure Fit an approved stop valve i on the cold water side as required by regulations. Refer also to paragraph 1.3 Regulations. 2. The maximum working pressure of the appliance is 8 bar. Because the pressure in the water pipe at times can exceed 8 bar, you must fit an approved pressure-reducing valve a. 3. Fit a non-return valve e and an expansion vessel b. 4. Fit a pressure relief valve n and connect the overflow side to an open wastewater pipe Shunt pipe You can connect a shunt pump to prevent stacking of the water in the water heater. 1. Optional: Depending on the consumption pattern, fit a shunt pipe (Ø 22 mm), stop valve i and a shunt pump k. 2. Fit a non-return valve e. 3. Fit a stop valve i Hot water side See b in Figure 3.2. n Note Insulating long hot water pipes prevents unnecessary energy loss. 1. Fit the T&P valve c. 2. Optional: fit a temperature gauge j to be able to check the temperature of the tap water. 3. Fit a stop valve i in the hot water outlet pipe, for use when servicing Drain valve 1. Fit the standard supplied drain valve g. 2. If a circulation pipe is to be fitted, then refer to paragraph Otherwise, fit the sealing nut and gasket supplied with the drain valve. See Figure Instruction Manual
27 is Water connections, Vented c Circulation pipe See c in Figure 3.2 and Figure 3.3. If an immediate flow of hot water is required at draw-off points, a circulation pump can be installed. This improves comfort and reduces water wastage. 1. Fit a circulation pump f of the correct capacity for the length and resistance of the circulation system. 2. Fit a non-return valve e behind the circulation pump to guarantee the direction of circulation. 3. Fit two stop valves d for service purposes. 4. Connect the circulation pipe to the T-piece on the drain valve g. See Figure 3.3. IMD-0122 Figure 3.3 Drain valve 3.7 Water connections, Vented Cold water side See a in Figure 3.2. Fit an approved stop valve i on the cold water side between the water cistern o and the appliance, as required by regulations. Refer also to paragraph 1.3 Regulations Shunt pipe You can connect a shunt pump to prevent stacking of the water in the water heater. 1. Optional: Depending on the consumption pattern, fit a shunt pipe (Ø 22 mm), stop valve i and a shunt pump k. 2. Fit a non-return valve e. 3. Fit a stop valve i Hot water side See b in Figure 3.2. n Note Insulating long hot water pipes prevents unnecessary energy loss. 1. Fit the T&P valve c. 2. Optional: fit a temperature gauge j to be able to check the temperature of the tap water. 3. Fit a stop valve i in the hot water outlet for servicing. 4. If a circulation pipe is to be fitted, then refer to paragraph Circulation pipe See c in Figure 3.2. If an immediate flow of hot water is required at draw-off points, a circulation pump can be installed. This improves comfort and reduces water wastage. 1. Fit a circulation pump f of the correct capacity for the length and resistance of the circulation system. 2. Fit a non-return valve e behind the circulation pump to guarantee the direction of circulation. Release R.2.0 Uk 27
28 3 Installation is 3. Fit two stop valves d for service purposes. 4. Connect the circulation pipe to the cold water supply pipe. 3.8 Gas connection Warning Gas installation may only be carried out by an authorised installer in compliance with the general regulations imposed by the gas company. Refer also to paragraph 1.3 Regulations. c Caution Make sure that the diameter and length of the gas supply pipe are large enough to supply sufficient capacity to the appliance. See d in Figure Fit a gas valve h in the gas supply pipe. 2. Blow the gas pipe through before use, to be sure it is clean. 3. Close the gas valve. 4. Fit the gas supply pipe to the gas control. Warning Check for leaks after fitting. 3.9 Flue gas discharge Warning The installation should be carried out by an authorised installer, in compliance with the general and local regulations imposed by gas, water supply and power supply companies and the fire service. Refer also to paragraph 1.3 Regulations. 28 Instruction Manual
29 is Flue gas discharge Introduction When connecting the appliance to the chimney, the draught diverter a supplied with the appliance must be used. The standard flue gas thermostat and sensor that are supplied must be fitted in the draught diverter. Legend a draught diverter b fastening screws c chimney pipe > 0.5 m c a b IMD Fitting the draught diverter De draught diverter a is fitted with two fastening screws b. The assembly procedure is as follows: 1. Place the draught diverter on the appliance and mark the drill holes. Again remove the draught diverter from the appliance. n Note The position of the holes already made for the flue gas backflow safeguard sensor must be taken into account. The holes should be roughly in line with the flue gas thermostat bracket. 2. Now drill two holes into the top of the appliance (3.2 mm drill bit). 3. Using the fastening screws, fix the draft diverter to the appliance. 4. Fit a chimney pipe c of at least 0.5 metres length to the opening of the draft diverter, before fitting the rest of the chimney materials according to current regulations. See paragraph 1.3 Regulations. n Note Use flue gas discharge materials that comply with the regulations. See paragraph 1.3 Regulations. n Note Make sure that the chimney discharges into an area where this is permitted for this category of appliance. Release R.2.0 Uk 29
30 3 Installation is Flue gas thermostat assembly The flue gas thermostat sensor is already mounted in the draught diverter. The bracket with thermostat needs to be mounted on the top of the unit and the cable from the thermostat needs to be connected with the connector on the unit. Warning If the flue gas thermostat is not (or is incorrectly) fitted/connected, the flue gas discharge will not be protected. An incorrectly fitted chimney can cause flue gases to backflow into the boiler room. n Note Figure 3.4 shows an example. For each type of unit the position of the sensor can slightly differ IMD-0187 Figure 3.4 Flue gas backflow detection Fit the flue gas thermostat as follows: 1. Remove the flue gas thermostat assembly a a from the packet. 2. Mount the bracket b with the thermostat on the top of the unit. 30 Instruction Manual
31 is Electrical connection 3. Connect the connector from the flue gas thermostat f to the connector on the appliance g Electrical connection Warning The installation should be carried out by an approved installer in compliance with the general and local regulations imposed by the gas, water and power supply companies and the fire service. Refer also to paragraph 1.3 Regulations Introduction Topics covered in this paragraph: Preparation; Mains voltage; Week timer circuit Connecting extra error signal ( Alarm OUT ) Preparation c Caution The appliance is phase-sensitive. It is absolutely essential to connect the phase (L) from the mains to the phase of the appliance, and the neutral (N) of the mains to the neutral of the appliance. There should also be no potential difference present between neutral (N) and earth (A). If this is the case, then an isolating transformer must be applied in the supply circuit. For more information, or to order this isolating transformer, please contact State. Figure 3.5 shows a front view of the electrical connection block. Table 3.8 shows the associated connections. Table 3.8 Electrical connection block Mains voltage Flue gas protection Week timer circuit Unused Potential free contact A L 1 N L 2 L 3 N N L L L L - NO P NC Release R.2.0 Uk 31
32 3 Installation is c 1 15 a b Figure 3.5 Connection block (connections 1 through 15 explained in Table 3.8) In preparation, first remove the protective cover from the control column: Undo the 4 screws a and remove the protective cover 2 from the electrical section. The connection block 3 is now visible. n Note Refer to A.2 Electrical diagram for the connection of electrical components. IMD Mains voltage The appliance is supplied without a power cord and main switch. n Note In order to receive electrical power, the appliance has to be connected to the mains voltage by means of a permanent electrical connection. A twoterminal main switch with a contact gap of at least 3 mm must be fitted between this fixed connection and the appliance. The power cord must have cores of at least 3 x 1.0 mm Lead the power cord through the metric pull relief on the top of the control column. 2. Connect earth (A), phase (L 1 ) and neutral (N) of the power cord to terminals 1 through 3 of the connection block as indicated in Table Tighten the pull relief so that the cable is clamped. 4. If you do not need to make any more connections, then fit the protective cover back on the control column. 32 Instruction Manual
33 is Checking the supply pressure and burner pressure 5. Connect the power cord to the main switch. Warning Leave the appliance disconnected until you are ready to start it up Week timer circuit 1. Cut out the week timer image from the control panel. 2. Fit the week timer in the hole. 3. Connect the week timer by connecting the wires with core bush to 7 (N), 9(L) and 11 (L). 4. Connect the cable with sliding bush to position B4 of the I/0/II switch. 5. If you do not need to make any more connections, then fit the protective cover back on the control column Connecting extra error signal ( Alarm OUT ) Alarm OUT is a potential free terminal that is switched when an error is detected. You can connect various objects to it. For example, a signalling lamp (max. 250V, 10A) to indicate malfunctioning of the appliance. The objects can be connected to normally open contacts (lamp ON on error) or to normally closed contacts (lamp OFF on error). 1. Feed the power cord through the metric pull relief on the top of the control column. 2. Connect the extra indicator at points 13 (NO) and 14 (P), and/or 14 (P) and 15 (NC) according to Table Tighten the pull relief so that the cable is clamped. 4. If you do not need to make any more connections, then fit the protective cover back on the control column Checking the supply pressure and burner pressure n Note Before you start up the appliance and/or begin to check the supply pressure and burner pressure, you must first fill the appliance. Please refer to paragraph 4.2 Filling the appliance for filling instructions. c Caution Before starting-up for the first time, and following conversion, you must always check the supply pressure and burner pressure. If necessary, adjust these to be certain of optimum performance of the appliance. n Note The easiest way to check the gas pressures is by using two pressure gauges. This procedure assumes that these two gauges are available. Release R.2.0 Uk 33
34 3 Installation is Legend a burner pressure regulator b burner pressure regulator cap c burner pressure regulator adjusting screw d gas control connector e flat sealing plate f supply pressure nipple g gas control h manifold nipple i high-low control Block for , , , , , , f e g d Block for a c b h IMD-0127 b c a i f g h IMD-0129 Figure 3.6 Gas blocks for the two designs 34 Instruction Manual
35 is Checking the supply pressure and burner pressure To check the supply pressure and burner pressure, proceed as follows: 1. Disconnect the appliance from the mains. See paragraph Disconnect the appliance from the mains. 2. On the gas control (Figure 3.6) there are two nipples. To check the supply pressure, nipple f is used. The other nipple on the gas control is not used. The manifold nipple h is used for measuring the burner pressure. Sealing screws are located inside the nipples. Loosen both sealing screws by a few turns. Do not loosen them completely; this makes them difficult to tighten again. 3. Connect a pressure gauge to the manifold nipple h. 4. Open the gas supply and vent the gas supply line via nipple f. 5. Connect a pressure gauge to nipple f as soon as gas starts to flow from this nipple. 6. Switch on the power to the appliance using the mains switch. 7. Set the control thermostat to the highest position and start the appliance running by putting the I/0/II switch to I position. 8. The heating cycle will start and the burner tray will ignite after a short time. 9. After the burner tray has ignited, wait for approximately 1 minute before you start reading the dynamic pressures. 10. Use the pressure gauge to read the supply pressure at nipple f. See Table 3.9. n Note Consult the mains gas supply company if the supply pressure is not correct. Table 3.9 Conversion data for appliance category II 2H Use the pressure gauge to read the burner pressure at the burner pressure nipple h. Refer to Table 3.9. DESCRIPTION Unit Data for natural gas, gas category 2H Diameter of orifices mm G20 Supply pressure mbar Burner pressure mbar Data for LP gas, gas category 3+ Diameter of orifices mm G30 (butane) Supply pressure mbar Burner pressure (1) mbar G31 (propane) Supply pressure mbar Burner pressure (1) mbar If using a flat sealing plate or high-low control program, instead of a burner pressure regulator, it is assumed that the burner pressure is equal to the supply pressure. In practice however, the burner pressure will be lower. Release R.2.0 Uk 35
36 3 Installation is n Note If the burner pressure is not correct and the appliance is fitted with a flat sealing plate or high-low control, you will not be able to adjust the pressure. In this case, consult your installer or supplier. If the appliance is fitted with a burner pressure regulator, then the pressure can be adjusted by following steps 12 through Remove the cap b from the burner pressure regulator a. 13. Adjust the burner pressure by turning the adjusting screw c, depending on the correction required: - Adjusting screw anticlockwise: burner pressure decreases. - Adjusting screw clockwise: burner pressure increases. 14. Cover the opening of the adjusting screw and check the burner pressure against the target value from Table If the pressure reading is not correct, repeat steps 13 and 14 until the correct pressure is attained. 16. Fit the cap b on the burner pressure regulator. 17. Shut down the appliance by putting the I/0/II switch to 0 position. 18. Shut off the gas supply. 19. Disconnect the two pressure gauges and re-tighten the sealing screws in the nipples. n Note Before starting-up the appliance, take time to fill in the warranty card supplied with the appliance. This enables us to guarantee the quality of our systems, and to further enhance our warranty procedure. Please return this card as soon as possible. Your customer will then receive a warranty certificate with our warranty conditions Conversion to a different gas category c Caution The conversion may only by carried out by an authorised installer Introduction If the appliance must operate on a family of gas (LP gas or natural gas) other than the category of gas for which the appliance has been set up at the factory, the appliance will have be adapted using a special conversion kit. c Caution Check the supply pressure and burner pressure after conversion. 36 Instruction Manual
37 is Conversion to a different gas category Legend a cover plate b locking strip c orifice with stamped figure Figure 3.7 Exchanging orifices IMD- Take care The burner may be hot. The conversion of the differs from the other -appliances. The conversion procedures are described in paragraphs: Conversion to a different gas through Conversion to a different gas category Conversion to a different gas through (80-115, , , , , , ) 1. Disconnect the appliance from the mains. See paragraph Disconnect the appliance from the mains. 2. Shut off the gas supply. 3. Unscrew the cover plate a from the burner support. 4. Use a suitable tool to remove the locking strips b. Note: the locking strips have very sharp edges. Withdraw the locking strips straight upwards. n Note The radiation shield / condensation tray can be temporarily loosened to simplify assembly of the burner. 5. Remove the burners one by one from their brackets at the front. To do this, you first move them away from you and then downwards. The orifices will now be accessible. Release R.2.0 Uk 37
38 3 Installation is 6. Remove the orifices. 7. Select and fit the correct orifices from the conversion kit, based on Table 3.9. The orifice diameter is stamped into each orifice c. Legend See Figure 3.7 for 1 through 3. d burner pressure regulator e gas control connector f flat sealing plate g supply pressure nipple h gas control g f h e d IMD-0131 Figure 3.8 Conversion of gas control 8. Refit the burners back in their original position. 9. Re-fit the locking strips. n Note If the radiation shield /condensation tray was loosened, re-tighten it. 10. Check whether the block is equipped with a burner pressure regulator d or a flat sealing plate f. 11. Check with Table 3.5 whether a burner pressure regulator is required for the new gas category. 12. If the flat sealing plate or burner pressure regulator need to be replaced: - Undo the gas control connector e. - Disassemble the flat sealing plate f or burner pressure regulator d. - Fit the flat sealing plate or burner pressure regulator supplied with the conversion kit. - Fit the gas control connector e. c Caution 13. Check the burner and supply pressure (see paragraph 3.11). 38 Instruction Manual
39 is Conversion to a different gas category 14. Remove the sticker showing the new gas category from the conversion kit, and attach it below the appliance s rating plate. This clearly indicates that the appliance may no longer be run on the gas for which it was originally supplied. 15. Start the appliance (see paragraph 7.2) Conversion to a different gas category Legend a burner pressure regulator b high-low control c gas control Introduction This paragraph describes the: Conversion from LP gas to natural gas. Conversion from natural gas to LP gas IMD-0132 Figure 3.9 Conversion of gas control Conversion from LP gas to natural gas 1. Perform steps 1 through 9 of paragraph Conversion to a different gas through Detach the high-low control b. 3. Fit the burner pressure regulator a including the sealing gasket from the conversion kit. Attach the burner pressure regulator to the gas control c using the two small screws supplied. Release R.2.0 Uk 39
40 3 Installation is Legend See Figure 3.9 for the numbers a to c. d timers e bracket f 6-terminal connector strip g pull relief h 9-terminal connector strip i metrical pull relief j high-low control cable IMD-0130 Figure 3.10 Fitting and removal of conversion components 4. Detach the cables between the 6-terminal connector strip f and 9-terminal connector strip h. These are the cables for the timers, high-low control, gas control, glow igniter and ionisation rod. 5. Undo timers d, bracket e, cable-harness (not shown) and the 9-terminal connector strip h. 6. Undo the metrical pull relief i with high-low control cable j. Remove this cable. 7. Fit the stop plug from the conversion set in the place of the metric pull relief. 8. Connect the cables of the gas control, the glow igniter, and ionisation rod to the 6-terminal connector strip as shown in the electrical diagram. See appendices A.2.1 Electrical diagram LP and A.2.2 Electrical diagram. 9. Clamp the gas control cable in one of the pull reliefs supplied g. Do the same for the cables from the glow igniter and ionisation rod. 40 Instruction Manual
41 is Conversion to a different gas category c Caution 10. Check the burner and supply pressure (see paragraph 3.11). 11. Remove the sticker showing the new gas category from the conversion kit, and attach it below the appliance s rating plate. This clearly indicates that the appliance may no longer be run on the gas for which it was originally supplied. 12. Start the appliance (see paragraph 7.2). Conversion from natural gas to LP gas 1. Perform steps 1 through 9 of paragraph Conversion to a different gas through Detach the burner pressure regulator a. 3. Fit the high-low control b including the sealing gasket from the conversion kit. Attach the high-low control to the gas control using two small screws. 4. Detach the cables from the gas control, the glow igniter, and the ionisation rod from the 6-terminal connector strip f and pull relief g. 5. Fit the timers d including cable harness plus 9-terminal connector strip h from the conversion kit, to the control column. 6. Remove the stop plug (not shown) from the underside of the control column and replace this with metrical pull relief i from the conversion kit. 7. Lead the high-low control cable j through the pull relief and tighten the pull relief by turning it until the cable is clamped. 8. Connect the high-low control cable j with connector to the high-low control b. 9. Connect the cables from the timers, high-low control, gas control and the glow igniter as shown in the electrical diagram. See appendix A.2 Electrical diagram. c Caution 10. Check the burner and supply pressure (see paragraph 3.11). 11. Remove the sticker showing the new gas category from the conversion kit, and attach it below the appliance s rating plate. This clearly indicates that the appliance may no longer be run on the gas for which it was originally supplied. 12. Start the appliance (see paragraph 7.2). Release R.2.0 Uk 41
42 3 Installation is 42 Instruction Manual
43 gis 4 Filling and draining Introduction 4.1 Introduction Topics covered in this chapter: Filling the appliance. Draining the appliance. The components referred to in these paragraphs are illustrated in Figure 4.1. Legend a pressure-reducing valve UNVENTED (obligatory) b expansion vessel (obligatory) c T&P valve (obligatory) d stop valve (recommended) e non-return valve (obligatory) f circulation pump (optional) g drain valve h gas valve (obligatory) i stop valve (obligatory) j temperature gauge (recommended) k shunt pump VENTED (optional) l draught diverter m hot water draw-off points n pressure relief valve (obligatory) o water cistern p float valve q 3-way aeration valve (recommended) r overflow pipe a cold water supply b hot water outlet c circulation pipe d gas supply e flue gas discharge 13 A IMD-0146 Figure 4.1 Installation diagrams IMD-0147 Release R.2.0 Uk 43
44 4 Filling and draining gis 4.2 Filling the appliance Filling unvented installations To fill the appliance, proceed as follows. 1. Open the valve i in the hot water pipe and, if present, the valve d for the circulation pump. 2. Close drain valve g 3. Open the nearest hot water draw-off points m. 4. Open the valve i on the cold water side a so that cold water flows into the appliance. 5. Completely fill the appliance (when cold water flows at normal pressure from the nearest hot water draw-off point, the appliance is full). 6. Bleed the entire installation of air, for example by opening all hot water drawoff points. 7. The appliance is now under water supply pressure. There should be no water coming out of the T&P valve. If this does happen, the cause might be: - The water supply pressure is greater than the specified 8 bar. Do place a pressure-reducing valve a after all. - The overflow valve in the protected cold supply setup is defective or incorrectly fitted Filling vented installations To fill the appliance, proceed as follows. 1. Open the valve i in the hot water pipe and, if present, the stop valves d for the circulation pump. 2. Close the drain valve g. 3. Open the nearest hot water draw-off point m. 4. Open the valve i on the cold water side a so that cold water flows into the appliance. 5. Completely fill the appliance (when cold water flows at normal pressure from the nearest hot water draw-off point, the appliance is full). 6. Bleed the entire installation of air, for example by opening all hot water drawoff points. 7. The appliance is now under water supply pressure. There should be no water coming out of the T&P valve c. If this does happen, the T&P valve might be defective or incorrectly fitted. 4.3 Draining the appliance Draining unvented installations Some service activities require the appliance to be drained. Proceed as follows: 1. Shut the appliance down by putting the I/0/II switch to 0 position. 2. Disconnect the appliance by putting the mains switch between the appliance and the mains power supply to 0 position. 3. Shut off the gas supply h. 4. Close the valve i in the hot water pipe b. 5. Close the valve i in the cold water supply a. 6. Open the drain valve g. 7. Bleed the appliance (or installation) so that it drains completely empty. 44 Instruction Manual
45 gis Draining the appliance Draining vented installations Some service activities require the appliance to be drained. Proceed as follows: 1. Shut the appliance down by putting the I/0/II switch to 0 position. 2. Disconnect the appliance by putting the mains switch between the appliance and the mains power supply to 0 position. 3. Shut off the gas supply h. 4. Close the stop valve valve i in the hot water pipe b. 5. Close the supply valve in the cold water supply. 6. Open the drain valve g. 7. Bleed the appliance (or installation) so that it drains completely empty. Release R.2.0 Uk 45
46 4 Filling and draining gis 46 Instruction Manual
47 0 1 gis 5 Operating Introduction 5.1 Introduction Topics covered in this chapter: 5.2 Control panel; 5.3 Explanation of the icons; 5.4 I/0/II switch; 5.5 Control thermostat; 5.6 Burner control reset button; 5.7 Week timer circuit; 5.8 Flue gas backflow safeguard reset button. 5.2 Control panel Figure 5.1 shows the control panel The panel consists of: a I/0/II switch; a reset button; a control thermostat with rotary knob; two status LEDs; a week timer (optional); a Power Anode indicator light (optional). d a b 0 1 Mon 0 12 Tue 1 0 Wed RESET 1 Sun 9 3 Thu 0 I O II 1 Sat 6 1 Fri Figure 5.1 The control panel c Release R.2.0 Uk 47
48 5 Operating gis 5.3 Explanation of the icons Table 5.1 shows the meanings of the icons on the control panel. Table 5.1 Icons and their meaning Icon Name Explanation I/0/II switch ON mode / OFF mode Reset button Reset burner control Temperature control To set water temperature (T set ) a Week timer Sets the weekly water heating program b Power Anode indicator lamp Shows Power Anode status c Error light Burner control lockout d Power light Burner control on power 5.4 I/0/II switch With the I/0/II switch, the appliance is set in ON mode (I position), OFF mode (0 position), or the week timer mode (II position). See paragraph 6.2 Operating modes. The appliance remains live, even when in the OFF mode. This ensures the frost protection remains activated. n Note To electrically disconnect the appliance, you must use the main switch between the appliance and the mains power supply. 5.5 Control thermostat Use the rotary knob on the control thermostat to set the desired water temperature to between ± 40 C and ± 70 C. The rotary knob is continuous, over a scale of 1 to 4. Table 5.2 shows the temperatures corresponding to each position. Table 5.2 Temperature setting Position Temperature 1 ± 40 C 2 ± 50 C 3 ± 60 C 4 ± 70 C 48 Instruction Manual
49 gis Burner control reset button 5.6 Burner control reset button An error can cause the burner control to lock out. When this happens, the red light on the control panel will illuminate. After eliminating the cause of the error, you can reset the appliance using the reset button. n Note Before resetting, always eliminate the cause of the error. To identify the various errors, refer to chapter 6 Status of the appliance. Chapter 8 Troubleshooting describes how to troubleshoot errors and problems. 5.7 Week timer circuit Optionally, you can use the week timer to program when the appliance must supply the heat demand. Set the I/0/II switch to the II position to activate the week timer circuit. On the week disc b of the timer switch a seven day segments are indicated Monday through Sunday. Each day is divided by 12 tabs f (2 hours per tab). To set a two-hour period during which the appliance must respond to a heat demand, press the tab for that period outwards. The current time can be read from the hands d (12 hour clock). Set the day and time as follows: to set the time roughly, rotate the week disc b in the direction of the arrow, until the correct weekday lies beside the arrow marker c. To finely set the time, rotate the minute hand clockwise until the correct time is set. The manual switch e must always be in the central position (this activates the timer program). Legend: a timer switch b week disc c arrow marker a d hands b e manual switch f tabs c d e f Figure 5.2 Week timer Release R.2.0 Uk 49
50 5 Operating gis 5.8 Flue gas backflow safeguard reset button A malfunction in the flue gas discharge, like a blockage in the chimney, can lead to the flue gas thermostat locking out. This state is evident when the push button on the flue gas thermostat is activated, see Figure 5.3. Once the cause has been removed, and the sensor has cooled down sufficiently, press this push button to reset (if the sensor is not sufficiently cooled down, the flue gas thermostat will immediately lock out again). The appliance will then automatically start up again, if there is a current heat demand. If this does not happen, refer to chapter 8 Troubleshooting for a complete troubleshooting guide. IMD-0151 Figure 5.3 Flue gas backflow safeguard reset button 50 Instruction Manual
51 gis 6 Status of the appliance Introduction 6.1 Introduction Topics covered in this chapter: 6.2 Operating modes; 6.3 Power Anode Status; 6.4 Error conditions. 6.2 Operating modes When running, the appliance has three basic operating modes, namely: DISCONNECTED In this mode the appliance is off and all components are electrically dead. The main switch (switch between the appliance and the power supply) is turned off. On the control panel: - the I/0/II switch is set tot the 0 position; - the green light is off. WEEK PROGRAM (optional) In this position the appliance only meets the heat demand during the periods set by the timer. Outside these periods, only frost protection is active. On the control panel: - The I/0/II switch is set to the II position. - The water temperature can be set by turning the rotary knob on the control thermostat, see paragraph 5.5 Control thermostat. - The period during which the heat demand must be fulfilled can be programmed using the week timer, see paragraph 5.7 Week timer circuit. - the green light is illuminated. n Note If no week timer is installed, the II mode is the same as the 0 mode. OFF In this mode, the frost protection is activated. The main switch is set to Iposition. On the control panel: - The I/0/II switch is set to the 0 position; - the green light is illuminated. ON In this mode the appliance continuously fulfils the demand for heat. On the control panel: - The I/0/II switch is set to the I position; - The water temperature can be set by turning the rotary knob on the control thermostat, see paragraph 5.5 Control thermostat ; - the green light is illuminated. 6.3 Power Anode Status If the appliance is fitted with a Power Anode, there is an extra indicator lamp on the operating panel. Depending on the status of the appliance, this lamp will be lit either Green or Red, or it will be Off: Release R.2.0 Uk 51
52 6 Status of the appliance gis Green This state indicates that the Power Anode is working correctly. Red This state indicated that the Power Anode is not working properly due to an error. Off This state indicates that the Power Anode is not working. n Note If there is an error with the Power Anode (Red), or if the Power Anode is not working (Off), this will have no effect on the hot water supply. 6.4 Error conditions If the appliance has an error, heat demand will be (temporarily) ignored. The frost protection will also be out of operation. There are various types of errors: Lockout error due to the flue gas backflow safeguard The lockout (push button) of the flue gas thermostat in de draught diverter has been activated. After removing the cause, the push button must be pressed to re-start the appliance (see 5.8 Flue gas backflow safeguard reset button ). Lockout errors of the burner control In this event, the red error light on the control panel will be illuminated. The burner control is locked out. After eliminating the cause, the appliance must be returned to service by pressing the reset button (see 5.6 Burner control reset button ). Blocking errors You can recognise this status by the fact that the appliance will not start operation, despite the water temperature being lower than you have set with the control thermostat (see 5.5 Control thermostat ). These errors disappear automatically once the cause of the error has been removed, after which the appliance resumes by itself. The cause of the error cannot be seen on the control panel. For a detailed overview of error conditions, please refer to chapter 8 Troubleshooting. If, as end-user, you find the appliance in an error condition, you may attempt to re-start the appliance by pressing the reset button once. However, should the error return or become persistent, you should contact your service and maintenance engineer. 52 Instruction Manual
53 gis 7 Starting up and shutting down Introduction 7.1 Introduction Topics covered in this chapter: Starting up; Shutting down; The appliance s heating cycle. 7.2 Starting up Start-up the appliance as follows: 1. Fill the appliance. See chapter 4 Filling and draining. 2. Open the gas valve (see Figure 4.1 Installation diagrams ). 3. Switch on the power to the appliance using the mains switch between the appliance and the power supply. 4. Set the appliance, using the I/0/II switch on the control panel, to the ON mode (I position) or in the weekly program mode (II position). See '6.2 operating states'. 5. Set the desired water temperature using the control thermostat. See paragraph 5.5 Control thermostat If there is a heat demand, the appliance will run through a heating cycle. See paragraph 7.4 The appliance s heating cycle. 7.3 Shutting down You can: Shut the appliance down for a brief period ( OFF mode ). Disconnect the appliance from the mains. Shut the appliance down for a longer period Shut the appliance down for a brief period ( OFF mode ) To shut the appliance down for a brief period, you must activate the frost protection. Refer also to paragraph 2.3 The appliance s heating cycle With the frost protection you can prevent water freezing in the appliance. Activate frost protection by switching the I/0/II switch on the control panel to the 0 position Disconnect the appliance from the mains The appliance should only be disconnected from mains power in the correct way. The correct procedure is as follows: 1. Shut the appliance down by putting the I/0/II switch to 0 position. 2. Disconnect the appliance by putting the mains switch between the appliance and the mains power supply to 0 position Shut the appliance down for a longer period Drain the appliance, if you are shutting it down for a longer period of time. Proceed as described in paragraph 4.3 Draining the appliance. Release R.2.0 Uk 53
54 7 Starting up and shutting down gis 7.4 The appliance s heating cycle The appliance s heating cycle is activated as soon as the measured water temperature (T water ) falls below the threshold value (T set ). This threshold value depends on the currently selected appliance operating mode. For example, if the appliance is in the OFF mode (frost protection), then this value is 20 C. If the appliance is in the ON mode, then this threshold value is selectable, for example, position 3 (±60 C). The heating cycle runs in turn through the following states: 1. HEAT DEMAND; 2. WAITING TIME; 3. PRE-GLOW; 4. IGNITION; 5. RUNNING; 6. WAITING TIME. The complete cycle is explained in the example set out below. n Note The appliance runs through an identical cycle when frost protection is activated. 1. The control thermostat sensor measures the water temperature. The water temperature falls below the set temperature, e.g. 60 C, causing the control thermostat to close. The burner control now detects a heat demand and starts the heating cycle. 2. Following the heat demand, the waiting time begins. This waiting time ensures the ignition takes place safely. The waiting time lasts about 15 seconds. 3. Once the waiting time is over (audible clicking of the relay in the burner control) the pre-glowing of the glow igniter is started. 4. After about 12 seconds (pre-)glowing, the gas control is opened and ignition can take place. 5. After ignition, the flame is detected and the appliance will be running. This means that actual heating has started. 6. When the water is up to temperature, the heat demand cuts out. The gas control closes, and the burner tray is extinguished. A new waiting time begins, of about 10 seconds. 7. After this waiting time, the appliance enters an idle state, and waits until the water temperature again falls below the set temperature. With any subsequent heat demand, the heating cycle will resume from step Instruction Manual
55 gis 8 Troubleshooting 8.1 Introduction This chapter covers the following errors: General errors: - Gas smell; - Water leakage; - Explosive ignition; - Poor flame profile; - Power Anode (optional). No hot water; Insufficient hot water. General errors cannot be displayed on the control panel, but these errors usually do not cause the hot water supply to fail, neither fully nor partially. If the hot water supply should fail, this is termed an error condition. See paragraph 6.4 Error conditions. If the hot water supplied is insufficient, this is usually caused by an incorrect setting, or some temporary problem. The following pages provide troubleshooting tables for each type of error. Release R.2.0 Uk 55
56 Warning Onderhoud mag alleen worden uitgevoerd door een service- en onderhoudsmonteur. is 8.2 Troubleshooting table for general errors Table 8.1 General errors (page 1 of 2) Symptom Cause Solution Remark Gas smell Gas leak Warning Immediately close the main gas valve. n Note Immediately contact your installer or local gas company. Warning Do not operate any switches. Warning No naked flames. Warning Ventilate the boiler room. Water leakage Leakage from one of the water connections (threaded). Tighten the threaded connection. If the leak persists, consult your installer. Leakage from another nearby water appliance or pipe segment. Trace the leak. Leakage from the appliance s tank. Consult the supplier and/or manufacturer. Condensation Before drawing off (too much) hot tap water, wait until the water in the heater has reached the set temperature. Release R.2.0 Uk 56
57 Warning Onderhoud mag alleen worden uitgevoerd door een service- en onderhoudsmonteur. Table 8.1 General errors (page 2 of 2) is Symptom Cause Solution Remark Explosive ignition Poor flame profile Incorrect supply pressure and/or burner pressure. Set the correct supply pressure and/or burner pressure, see 3.11 Checking the supply pressure and burner pressure. If ignition is not improved, consult your installer. Contaminated burner Clean the burner. See Cleaning the burners Contaminated orifice. Clean the orifice. See Cleaning the orifices Inadequate air supply Improve the air supply by better ventilating the boiler room. Power Anode (optional) If the malfunction cannot be solved, consult your installer. Indicator lamp is red Anodes not making contact with the water; Break in one of the cables; Anode poorly earthed; 1. Check that the water heater is full of water; 2. Check that the Power Anode is properly connected, see appendix A Electrical scheme '; 3. Check to see that all connections are properly made; 4. Check all cables for breaks and replace if any are found. Indicator lamp is off No power supply to the potentiostat; Check the power supply 8.3 Troubleshooting table no hot water If the appliance fails to supply any hot water, there are several possible causes. Refer to table Table 8.2 No hot water. Release R.2.0 Uk 57
58 Warning Onderhoud mag alleen worden uitgevoerd door een service- en onderhoudsmonteur. Table 8.2 No hot water (page 1 of 2) is Symptom Cause Solution Remark Green light OFF and Red light OFF No mains power present 1. Check that the mains switch is ON. 2. Check the voltage across the main switch. 3. Check the voltage on the electrical connector block. See appendix A.2 Electrical diagram. If you cannot resolve the error, contact your installer. 4. Check the voltage on the burner control. 5. Check the fuse in the burner control. The measured voltage must be 230V AC +15% -10%. Green light ON and Red light OFF. Blockage in the flue gas discharge (the flue gas backflow safeguard has cut out) 1. Trace the blockage. 2. Remove the blockage. 3. Reset flue gas backflow safeguard. See paragraph 5.8 Flue gas backflow safeguard reset button. When heat demand is detected, the appliance will re-start. Release R.2.0 Uk 58
59 Warning Onderhoud mag alleen worden uitgevoerd door een service- en onderhoudsmonteur. Table 8.2 No hot water (page 2 of 2) is Symptom Cause Solution Remark Green light ON and Red light ON. There are three possible causes for this error. To determine the cause, the error must be made to recur: 1. Reset the appliance by pressing the reset button 1x. 2. Should nothing happen, then the reset button has already been pressed too often (maximum 5x in a single heating cycle) and you will have to first electrically disconnect the appliance, then start it again. See paragraph Disconnect the appliance from the mains and steps 3 through 5 of paragraph 7.2 Starting up. 3. Decide which type of cause (a) or (b) describes the situation. (a) three unsuccessful start attempts in a row (b) The safety thermostat has cut out 1. No gas: Check that the gas valve is open. Check that gas control opens (clicking of the gas control). Check the gas control wiring. 2. No ignition: Check whether the glow igniter lights up. Check the power supply to the glow igniter. Check the wiring of the glow igniter. 3. No flame detection: Check that the Phase (L) and Neutral (N) are correctly connected (from the mains) to the appliance Check that the ionisation rod is not defective. Check that the wiring to the ionisation rod is correctly connected. 1. The safety thermostat has cut out correctly: Reset the appliance. Check whether the control thermostat is working. Check whether the high-limit thermostat is working. Check that the circulation pump (if present) is working. 2. The safety thermostat has cut out without apparent reason: Check whether the thermostat may be broken. Check whether the thermostat sensor may be broken. If the error cannot be resolved or is persistent, contact your installer. If the error cannot be resolved or is persistent, contact your installer. Release R.2.0 Uk 59
60 Warning Onderhoud mag alleen worden uitgevoerd door een service- en onderhoudsmonteur. 8.4 Troubleshooting table insufficient hot water If the appliance fails to supply any hot water, there are several possible causes. Refer to Table 8.3 Insufficient hot water Table 8.3 Insufficient hot water is Symptom Cause Solution Remark Insufficient hot water The water temperature setting (T set ) is too low Set the control thermostat to a higher setting. See paragraph 5.5 Control thermostat. Hot water supply used up. 1. Reduce the rate of hot water consumption. Allow the appliance enough time to heat up the water. 2. If this error occurs regularly, check whether the high-limit thermostat is cutting in/out. If so, check that the circulationand/or shunt pump are working properly. If the error has not been rectified, and no other cause can be found, disconnect the appliance from the mains, shut off the gas valve and alert your installer. Release R.2.0 Uk 60
61 s 9 Maintenance Introduction 9.1 Introduction c Caution Maintenance may only by carried out by an approved service and maintenance engineer. At each service, the appliance undergoes maintenance both on the water side and on the gas side. The maintenance should be carried out in the following order. 1. Preparation for maintenance; 2. Water-side maintenance; 3. Gas-side maintenance; 4. Finalising maintenance. n Note Before ordering spare parts, take a moment to write down the appliance type and model, and the full serial number of the appliance. Only by ordering with this information can you be sure to receive the correct spare parts. These details can be found on the rating plate. 9.2 Preparation for maintenance To test whether all components are still working properly, you should complete the following steps: 1. Put the I/0/II switch on the control panel to 0 position. 2. Set the control thermostat to the highest position (take note of the original setting) and put the I/0/II switch back to I position. 3. If there is no heat demand, draw some hot water off to initiate a heat demand. 4. Check whether the heating cycle runs correctly. See paragraph 7.4 The appliance s heating cycle. 5. Set the control thermostat back to the original setting, and put the I/0/II switch back to I position. 6. Check the supply and burner pressures and adjust these, where necessary. See paragraph 3.11 Checking the supply pressure and burner pressure. 7. Check that all components of the flue gas system are properly attached. 8. Test the operation of the overflow valve of the cold supply setup. The water should spurt out. 9. Test the overflow operation of the T&P valve. The water should spurt out. 10. Check the wastewater pipes of the overflow valves and remove any lime buildup that may be present. 11. Drain the appliance. See paragraph 4.3 Draining the appliance. Release R.2.0 Uk 61
62 9 Maintenance s 9.3 Water-side maintenance Take care The draught diverter and the cover may be hot Introduction The following steps should be carried out on the water side: 1. Checking the anodes. 2. Descaling and cleaning the tank Checking the anodes Timely replacement of the anodes extends the service life of the appliance. The appliance s anodes must be replaced as soon as they are 60% or more used up (take this into consideration when determining the maintenance frequency). 1. Disassemble the protective cap on the control column by loosening the 4 screws on the cap. 2. Disconnect the draught diverter from the flue gas discharge. 3. Undo the screws on the draught diverter. 4. Remove the draught diverter from the appliance. 5. Undo the screws on the draught diverter. 6. Remove the cover from the appliance. 7. Remove the sealing ring from the tank. 8. Loosen the anodes using suitable tools. 9. Check the anodes, and if necessary, replace them. 10. Now also check the flue baffles. Replace them, if necessary. See paragraph Checking the flue baffles. 11. Fit a new sealing ring around the edge of the tank and replace the cover. 12. Reconnect the wiring for the flue gas thermostat to the connector of the appliance. n Note For this appliance Power Anodes might be used as well. These anodes require less to no maintenance. The anodes are deliverable as an option and can be ordered separately. See the instructions coming with these anodes or contact your installer. Figure 9.1 Cleaning opening Descaling and cleaning the tank Scale and lime buildup prevent effective conduction of the heat to the water. Periodic descaling prevents buildup of these deposits. This increases the service life of the appliance, and also improves the heating process. Take the rate of scale formation into account when deciding on maintenance frequency. 1. Remove the cover plate 1 on the outer jacket. See Figure Undo the bolts. 3. Remove the cover and the rubber O-ring. 4. Inspect the tank and remove any contamination. 5. Remove the scale using Borcoil (1). 6. Close the cleaning opening. Use a new rubber O-ring for this. 1. State recommends the use of Borcoil, as the composition of this material is known to us. Borcoil can be ordered from State. 62 Instruction Manual
63 s Gas-side maintenance 9.4 Gas-side maintenance Introduction The following steps should be carried out on the gas side: Take care 1. Cleaning the burners. The burners may be 2. Cleaning the orifices. hot. 3. Checking the flue baffles Cleaning the burners 1. Detach the burners. 2. Carefully remove any contamination present on the burners. 3. Re-attach the burners Cleaning the orifices 1. Remove the orifices. 2. Remove any contamination present in the orifices. 3. Re-attach the orifices Checking the flue baffles Take care 1. Complete steps 1 through 9 of paragraph Checking the anodes. The flue baffles may 2. Remove the flue baffles from the appliance. be hot. 3. Check the flue baffles for rust, and remove any which is present. 4. Check the flue baffles for wear, and replace any worn flue baffles. 5. Complete steps 11 and 12 of paragraph Checking the anodes 9.5 Finalising maintenance To finalise the maintenance carry out the following steps: 1. Fill the appliance. See paragraph 4.2 Filling the appliance. 2. Start-up the appliance. See 7.2 Starting up. Release R.2.0 Uk 63
64 9 Maintenance s 64 Instruction Manual
65 gis General warranty 10 Warranty (Certificate) To register your warranty, you should complete and return the enclosed warranty card after which a warranty certificate will be sent to you. This certificate gives the owner of a water heater supplied by State Water Heaters B.V. of Veldhoven, The Netherlands (hereinafter State ) the right to the warranty set out below, defining commitments of State to the owner General warranty If within one year of the original installation date of a water heater supplied by State, following verification, and at the sole option of State, a part or component, (with exclusion of the tank) proves to be defective or does not function correctly due to manufacturing and/or material defects, State shall replace or repair this part or component Tank warranty If within 3 years of the original installation date of a water heater supplied by State, following inspection, and at the sole option of State, the glass-lined steel tank proves to be leaking due to rust or corrosion occurring on the water side, State shall provide an entirely new water heater of equivalent size and quality. The warranty period given on the replacement water heater shall be equal to the remaining warranty period of the original water heater that was supplied. Notwithstanding that stated earlier in this article, in the event that unfiltered or softened water is used, or allowed to stand in the water heater, the warranty shall be reduced to one year from the original installation date Installation and conditions of use The warranty set out in article 1 and 2 will apply solely under the following conditions: a. The water heater is installed under strict adherence to the installation instructions of State applying to the specific model, and the relevant local authority installation and building codes, rules and regulations in force. b. The water heater remains installed at the original site of installation. c. The appliance is exclusively used with drinking water, which at all times can freely circulate (a separately installed heat exchanger is mandatory for heating salt water or corrosive water). d. The tank is safeguarded against harmful scaling and lime buildup by means of periodic maintenance. e. The water temperatures in the heater do not exceed the maximum setting of the thermostats, which form a part of the water heater. f. The water pressure and/or heat load do not exceed the maximum values stated on the water heater rating plate. g. The water heater is installed in a non-corrosive atmosphere or environment. h. The water heater is connected to a cold water supply arrangement, which is: approved by the relevant authority; with sufficient capacity for this purpose; supplying a pressure no greater than the working pressure stated on the water heater; and where applicable, fitted with a temperature and pressure relief valve compliant with the installation instructions of State pertaining to the specific model of water heater, and under adherence to the relevant local authority installation and building codes, rules and regulations in force. i. At all times the appliance must be equipped with a protection in the form of anodes. If sacrificial anodes are used they must be replaced when and if they are used for 60% or more. If electrical anodes are used they should be operational at all times. Release R.2.0 Uk 65
66 10 Warranty (Certificate) gis 10.4 Exclusions The warranty set out in article 1 and 2 will not apply, in the event of: a. damage to the water heater caused by an external factor; b. misuse, neglect (including frost damage), modification, incorrect and/or unauthorised use of the water heater and any attempt to repair leaks; c. contaminants or other substances having been allowed to enter the tank; d. the conductivity of the water being less than 125 µs/cm and/or the hardness (alkaline-earth ions) of the water being less than 1.00 mmol/lit (see Table 3.3); e. unfiltered, recirculated water flowing through or being stored in the water heater; f. any attempts at repair to a defective water heater other than by an approved service engineer Scope of the warranty The obligations of State pursuant to the specified warranty do not extend beyond free delivery from the Veldhoven warehouse of the replacement parts or components or water heater. Shipping, labour, installation and any other costs associated with the replacement will not be accepted by State Claims A claim on grounds of the specified warranty must be submitted to the dealer from whom the water heater was purchased, or to another authorised dealer for the products of State Water Heaters. Inspection of the water heater as referred to in articles 1 and 2 shall take place in one of the laboratories of State Limitation of liability State State grants no other warranty or guarantee over its water heaters nor the (parts or components of) water heaters supplied for replacement, other than the warranty expressly set out in this Certificate. State is not liable for damage to persons or property caused by (parts or components, or the glass-lined steel tank of) a (replacement) water heater that it has supplied under the terms of this warranty, nor on any other grounds. 66 Instruction Manual
67 is A Appendices A.1 Introduction This appendix contains: The Electrical diagram. Release R.2.0 Uk 67
68 A A.2 Electrical diagram A.2.1 brown blue yellow/green black Appendices Electrical diagram LP is TERMINAL STRIP CONNECTIONS: A Earth N Neutral L Phase L 1 Phase input to controller L 2 Phase input to flue gas backflow safeguard L 3 Phase input safety circuit for enabling temperate control NO Normally open P PVC supply NC Normally closed COMPONENTS: A burner control Double-pole main switch - N Neutral - A Earth - L I Phase input to controller - L II Phase output - TH Phase input of thermostat circuit - GV1 Phase output to gas control - MAX Phase input of safety thermostat - LG Phase output to glow igniter - I Ionisation detection = output - NO Normally open Figure A.1 Electrical scheme LP B C D E F G H J K L M N O - P Phase input alarm - NC Normally closed - F1 Fuse (T5A) - R1 Relay max 250V-10A Frost thermostat Control thermostat I/0/II-switch Safety thermostat Max. thermostat Gas block Glow igniter Ionisation pin High-low control Timer Error signalling Signalling In operation Reset button OPTIONAL COMPONENTS: P Main switch Q Potentiostat (for power anodes) R Thermal Reflux Safeguard (TRS) S Week timer control 68 Instruction Manual
69 is Electrical diagram A.2.2 Electrical diagram brown blue yellow/green black white TERMINAL STRIP CONNECTIONS: A Earth N Neutral L Phase L 1 Phase input to controller L 2 Phase input to flue gas backflow safeguard L 3 Phase input safety circuit for enabling temperate control NO Normally open P PVC Supply NC Normally closed COMPONENTS: A Double-pole main switch - N Neutral - A Earth - L I Phase input to controller - L II Phase out - TH Phase input of thermostat circuit - GV1 Phase output to gas control - MAXPhase input of safety thermostat - LG Phase output to glow igniter - I Ionisation-detection = output Figure A.2 Electrical diagram B C D E F G H J M L M - NO Normally open - P Phase in: alarm - NC Normally closed - F1 Fuse (T5A) - R1 Relay max 250V-10A Frost protection thermostat Control thermostat I/0/II-switch Safety thermostat High-limit thermostat Gas valve Glow plug Ionisation rod Error signalling Signalling In operation Reset button OPTIONAL COMPONENTS: N Mains switch control O Potentiostat (for power anodes) P Thermal Reflux Safeguard (TRS) Q Week timer control Release R.2.0 Uk 69
70 A Appendices is 70 Instruction Manual
71 gis IX Index Index A B ambient temperature appliance functional description heating cycle installation types protection burner pressure H I heat demand heating cycle , 54 hot water side humidity icons ignition installation diagram installer ionisation rod C D check supply pressure, burner pressure circulation pipe claims cold water side , 27 condensation drainage connect connect circulation pipe cold water side , 27 condensation drainage electrical gas hot water side control thermostat conversion to different gas descaling dimensions document contents draining L M liability lime mains power mains switch maintenance anode burner carrying out descaling finalising gas-side lime buildup orifice preparation water-side mode OFF ON E F electrical connection electrical connection block electrical data electrical diagram environmental conditions filling floor loading forms of notation frost protection activation functional description O P R operating modes packaging power cord pre-glow protection reset button running G gas connection gas conversion S safety scale service check service engineer shunt pump , 27 Release R.2.0 Uk 71
72 IX Index gis shutting down brief period disconnecting longer period specifications stacking , 27 starting up state electrically disconnected HEAT DEMAND IGNITION PRE-GLOW RUNNING WAITING TIME supply pressure symbol installer service engineer user T U W target groups trademarks user waiting time warranty exclusions general installation and conditions of use scope tank water composition stacking , Instruction Manual
ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.
ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the
BFC. High Efficient Condensing Water Heater BFC - 28/30/50/60/80/100/120. Installation, User and Service Manual. Innovation has a name.
BFC High Efficient Condensing Water Heater BFC - 28/30/50/60/80/100/120 5015 - Changes Reserved. 0311704 Installation, User and Service Manual Innovation has a name. your installer A.O. Smith UK, Unit
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
35-130 45-190. Installation User and Service Manual A DIVISION OF A. O. SMITH CORPORATION
35-130 45-190 Installation User and Service Manual WATER PRODUCTS COMPANY A DIVISION OF A. O. SMITH CORPORATION www.aosmithinternational.com your installer Carefully read this manual Warning Carefully
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
Gas Instantaneous Water Heater
6 720 607 884 (2009/05) GB Installation Manual and Operating Instructions Gas Instantaneous Water Heater WR8..P... WR11..P... With piezo ignition and double safety system consisting of flue gas monitor
USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book
USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
SF15K SF05KSS, SF10KSS
Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user
For the user Instructions for use ecomax Wall hung room sealed fan assisted condensing boilers ecomax 63/ E ecomax 68/ E ecomax 6/ E ecomax 635 E ecomax 84/ E ecomax 88/ E ecomax 835 E GB Table of contents
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005
CUENOD Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CELTIC RSc b R8202395-02EN - Edition 02-21/04/2005 Boilers Solar Panel 69214511 31 CELTIC
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
orlando OWNER S MANUAL
orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
SERVICE MANUAL Order No.WH0911S001V0
SERVICE MANUAL Order No.WH0911S001V0 Electrical Water Heater Model No. FCD-JTSA50-III FCD-JTSA60-III FCD-JTSA70-III FCD-JTSA80-III! WARNING This service information is designed for experienced repair technicians
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions
Part No. 130009 Iss. 12 August 2004 Elson www.elsonhotwater.co.uk Open Vented Thermal Store providing mains pressure hot water heated by electricity Installation, Servicing and User's Instructions Read
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Tankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRTNG199 / WGRTLP199 WGRTCNG199 / WGRTCLP199 NOTICE: Westinghouse reserves the right to make product changes or updates without notice and will not
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Oil - kerosene burners
Installation, use and maintenance instructions Oil - kerosene burners One stage operation CODE MODEL TYPE 3747469 G0 474T5 90 (0) - 05/008 TECHNICAL FEATURES Thermal power output 95 3 kw 8 8 kg/h Fuel
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER
INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER Installation and service must be performed by a qualified service installer, service agency or the gas supplier. Oil Gas/Oil
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Pre-installation Manual. CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP
Pre-installation Manual CONCEPT Processor 305 DW / 405 DW / 505 DW 505 DW XP Pre-installation Manual CONCEPT Processor 305 DW / 405 DW / 505 DW / 505 DW XP T11336 Edition AA, April 2013 This book has
Session 2: Hot Water Supply
MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:
Unvented water heater
Unvented water heater Description of water heater 1)Hot water outlet 2)Temperature and pressure relief valve (30 litre only) 3)Cold water inlet 4)Control cover 5)Regulation knob 6)Heating neon 1 4 5 6
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths
SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths Operating instructions Universal water baths SUB6: 6 litres SUB14: 14 litres SUB28: 28 litres SUB36: 36 litres Boiling baths SBB6:
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
SHC 2.5, SHC 4 MINI-TANK ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER SHC 2.5 SHC 4. English. English
SHC 2.5, SHC 4 MINI-TANK ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER The SHC series is tested and certified by WQA against NSF/ANSI 372 for lead free compliance. SHC 2.5 Table
Stove-boiler for solid fuels 12-30 KW Directions for use and assembling
Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Response: The combi boiler. Response: The fit anywhere combi
Response: The combi boiler The Ideal Response is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers hot water on demand. It has been designed to be
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Electric Water Heater
Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.
G670 Intermittent Pilot Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin Issue Date 0300 Intermittent Pilot Ignition Controls Figure 1: Intermittent Pilot Ignition Control
User Manual THR840DUK Digital Thermostat
User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:
Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,
Assembly and instructions
Assembly and instructions Franke Minerva 3-in-1 Kettle Tap Retain for reference NB: For use only with Franke Heating Tank INTRODUCTION The Kettle Tap is suitable for dispensing boiling water (100 C) and
E-gas Instant Gas Water Heaters
The Proven Preferred Choice! E-gas Instant Gas Water Heaters Training & Information Manual: There are important functional and operational differences between the conventional hot water geyser and the
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
V94 BULK TAPE DEGAUSSER
TECHNICAL MANUAL Operating and Maintenance Instructions for V94 BULK TAPE DEGAUSSER V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Document No. M000208 Production Standard ZZ 009 415 WARNING To help minimise
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
Operating instructions
6300 9681 02/2006 GB For the user Operating instructions Logano GE315 Boiler for oil-/gas-fired pressure jet burners Please read thoroughly before use. Operating instructions Logano GE315 Dear Customer,
Baxi Combi 80e & 105e
Baxi Combi 8e & 15e Please keep these instructions safe. Should you move house, please hand them over to the next occupier. Gas Fired Wall Mounted Combination Boiler User s Operating Instructions Natural
800-292-3279 916 638-0828
800-292-3279 916 638-0828 http://easycleansystems.com/heaters/heater-parts.html VAL6 KBE5S and KBE5L Service manual KBE5S 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information
Steam Humidifier Model 800 Residential Steam Humidifier Owner s Manual Includes Safety & Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Safety Cautions...
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Draining and filling cooling system
Page 1 of 9 Draining and filling cooling system Special tools and workshop equipment required Adapter -V.A.G 1274/8- Pipe -V.A.G 1274/10- Drip tray -V.A.G 1306- or drip tray for workshop hoist -VAS 6208-
Commercial Gas Water Heater
Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service
UDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No.
Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA PIPING GUIDE GF-115-P Modulex Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909,
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
INDIRECT WATER HEATER. Installation and Operating Instruction Manual
INDIRECT WATER HEATER Installation and Operating Instruction Manual Maximum supply temperature to heat exchanger must not exceed 180 F (82 C). Safety Warning: Indirect water heaters are heat-producing
Accessory Manual Ventilation Section Model Comfort Circle
Accessory Manual Ventilation Section Model Comfort Circle Manual version:. R a Copyright and trademarks All the information and drawings in this manual are the property of Biddle and may not be used (other
CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL 1001.1 Scope. This chapter shall govern the installation, alteration and repair of boilers, water heaters and pressure vessels.
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
STOVE-BOILER FOR SOLID FUELS Directions for use and assembling
STOVE-BOILER FOR SOLID FUELS Directions for use and assembling Sadrºaj 1 Technical data 2 1.1 Boiler properties TEMY PLUS P 25............................. 3 1.2 On Product............................................
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS Applied Energy Products Limited, Morley Way, Peterborough, PE2 9JJ, UK Telephone: +44 (0) 844 372 7761 / Fax: +44 (0) 84 372 7762 Website:
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480
Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions
Unvented water heater
Unvented water heater 62 This product confirms to EU Directive 2002/96/EC. The symbol of the crossed waste paper basket on the appliance indicates that at the end of its working life the product should
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces
Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces Installation Instructions Kemlan Natural Draft Electronic Ignition 3 Sided Gas Fireplaces Natural Draft Electronic Ignition
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)
Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Commercial Gas Water Heaters
POWERED BURNER MODELS LARGE-VOLUME POWERED BURNER FEATURES The large-volume powered burner line includes the largest, most powerful A. O. Smith tanktype gas water heaters. With tank capacities up to 600