Electric Heat Tracing INSTALLATION PROCEDURES
|
|
|
- Philip Snow
- 10 years ago
- Views:
Transcription
1 INSTALLATION PROCEDURES
2 The following installation procedures are suggested guidelines for the installation of a Thermon electric heat tracing system 1. Individuals installing these products are responsible for complying with all applicable safety and health guidelines. Proper personal protective equipment, or PPE, should be utilized during installation. Contact Thermon if you have any additional questions. Applications Electric heat tracing cables are used for freeze protection or temperature maintenance of piping, tanks and instrumentation. This set of instructions covers typical piping applications. For installation details on tanks and instrumentation, refer to the Installation Guides on our website 2. Heat tracing cables may be installed in ordinary (nonclassified) and hazardous (classified) locations depending on the specific cable options and approvals 2. The National Electric Code and Canadian Electrical Code require ground-fault protection be provided for electric heat tracing. Complete Electric Heat Tracing System... A complete electric heat tracing system will typically include the following components 1 : 1. Electric heat tracing cable 2 (self-regulating, power-limiting, parallel constant watt or series constant watt). 2. Power connection kit. 3. RTD sensor or control thermostat In-line/T-splice kit (permits two or three cables to be spliced together). 5. Cable end termination. 6. Attachment tape (use on 12 intervals or as required by code or specification). 7. Electric Heat Tracing label (peel-and-stick label attaches to insulation vapor barrier on 10 intervals or as required by code or specification). 8. Thermal insulation 4 and vapor barrier (by others). The absence of any of these items can cause a system to malfunction or represent a safety hazard. Illustration A: Typical Heat Tracing Installation Types of s... Self-Regulating s: BSX Self-Regulating (refer to Form TEP0067) RSX Self-Regulating (refer to Form TEP0004) KSX Self-Regulating (refer to Form TEP0072) HTSX Self-Regulating (refer to Form TEP0074) VSX Self-Regulating (refer to Form TEP0008) Power-Limiting : HPT Power-Limiting (refer to Form TEP0011) 8 6 Parallel Constant Watt : FP Parallel Constant Watt (refer to Form TEP0016) 7 Series Constant Watt s: TEK Series Constant Watt (refer to Form TEP0021) HTEK Series Constant Watt (refer to Form TEP0022) 3 1 Notes Illustration depicts a typical self-regulating heating circuit. 2. Ground-fault equipment protection is required for all heat tracing circuits. 3. Temperature control is recommended for all freeze protection and temperature maintenance heat tracing applications. 4. All heat-traced lines must be thermally insulated. 5. Refer to Thermon form number PN50273 for installation instructions for MIQ mineral insulated heating cables. 2 1
3 Upon Receiving, Cable Upon receiving heating cable, check to make sure the proper type and output have been received. All flexible cables have the catalog number, voltage rating and watt output printed on the jacket. 2. Visually inspect cable for any damage incurred during shipment. The heating cable should be tested to ensure electrical integrity with at least a 500 Vdc megger between the heating cable bus wires and the heating cable metallic braid. IEEE 515 recommends that the test voltage for polymer insulated heating cables be 2500 Vdc. Minimum resistance should be 20 megohms. Connect the positive lead of the megger to the cable bus wires and the negative lead to the metallic braid. (Record 1 on Cable Testing Report.) 3. Store in dry location. Illustration B: vs. Sensor Location Before Installing Cable Be sure all piping and equipment to be traced is completely installed and pressure tested. 2. Surface areas where heat tracing is to be installed must be reasonably clean. Remove dirt, rust and scale with a wire brush and oil and grease films with a suitable solvent. Initial Installation Locate the cable on the lower quadrant of the pipe at the 4 or 8 o clock position. If accessibility is a problem the cable may be installed at the 10 or 2 o clock position. Temperature sensor should be located at least 90 from all heating cables. Refer to Illustration B for vs. Sensor Location. 2. Begin temporary installation at the proposed end-of-circuit location and lay out heating circuit on the pipe, allowing extra cable for the power connection and for any splice locations 3. Refer to Illustration C for temporary installation. 3. Make heating cable allowances for valves, flanges, elbows and supports as per the applicable drawings and table on pages 3 and 4 of these installation procedures. Temperature Sensor 45º Pipe Wall 90º 45º 90º 45º 45º 45º 45º 45º Single Cable Installation Dual Cable Installation Triple Cable Installation Illustration C: Temporary Installation Proposed End-of-Circuit Location Pipe Support Proposed Power Connection Location Cable Allowance for In-Line Heat Sinks Notes Termination kits to fabricate a heat tracing circuit are not addressed in detail in these installation procedures. Refer to installation instructions included with cable termination kits or contact Thermon for specific instructions to fabricate heating cable. 2. For information on specific cable types and options, refer to Types of s on page Heating cable minimum bend radius is 10mm (3/8 ) at -15 C (5 F). See product specification sheet for additional details. 2
4 Installation on Elbows, Supports and Flanges Install heating cable in accordance with Illustrations D, E and F below. Secure heating cable to piping using attachment tape. 2. Elbows: Locate the cable on the outside radius of an elbow to provide sufficient heat to compensate for the added piping material. Secure the cable to the pipe on each side of the elbow with attachment tape. 3. Pipe Supports: Insulated pipe supports require no additional heating cable. For uninsulated supports, allow two times the length of the pipe support plus an additional 15 (40 cm) of heating cable. 4. Flanges: Allow cable to be looped around pipe on each side of and adjacent to the flange. Heating cable must maintain contact with flange when bending around pipe flanges to compensate for additional heat loss. 5. Refer to the product specifications sheet for minimum bend radius for the specific cable type. Do not exceed bend radius when completing installation. Illustration D: Pipe Elbow Illustration E: Pipe Support 3 Min. (8 cm) Illustration F: Pipe Flange 3 Min. (8 cm) Support Length Circuit Layout on Support Note: Flange allowance will vary based on method of insulating flange and adjacent piping. 12 Max. (30 cm) 3
5 Installation on Valves and Pumps Install heating cable in accordance with Illustrations G and H below. Secure heating cable to piping using attachment tape. 2. Additional cable is required to provide extra heat at valves, pumps and miscellaneous equipment to offset the increased heat loss associated with these items. Refer to Table 1 for estimated cable requirements for installation on typical valves and pumps. Allowances shown in Table 1 are for 150 pound valves. More cable is required for higher rated valves. Refer to heat trace isometric drawing for project specific allowances. 3. Install heating cable on valves and pumps utilizing a looping technique (this allows the valve or pump to be removed if required). Crossing constant watt heating cable over itself should be avoided. 4. Refer to the product specifications sheet for minimum bend radius for the specific cable type. Do not exceed bend radius when completing installation. Illustration G: Typical Valve Detail Pipe Size Screwed or Welded Table 1: Valve and Pump Allowances 1 Valve Allowance Illustration H: Typical Pump Detail Pump Allowance Flanged Butterfly Screwed Flanged Flange Allowance ½" 6" 1' 0 1' 2' 1 3" ¾" 9" 1' 6" 0 1' 6" 3' 1 6" 1" 1' 2' 1' 2' 4' 1 6 1¼" 1' 6" 2' 1' 3' 4' 6" 2 0" 1½" 1' 6" 2' 6" 1' 6" 3' 5' 2 0" 2" 2' 2' 6" 2' 4' 5' 6" 2 3" 3" 2' 6" 3' 6" 2' 6" 5' 7' 2 3" 4" 4' 5' 3' 8' 10' 2 9" 6" 7' 8' 3' 6" 14' 16' 3 3" 8" 9' 6" 11' 4' 19' 22' 3 9" 10" 12' 6" 14' 4' 25' 28' 4 3" 12" 15' 16' 6" 5' 30' 33' 5 0" 14" 18' 19' 6" 5' 6" 36' 39' 5 6" 16" 21' 6" 23' 6' 43' 46' 6 0" 18" 25' 6" 27' 6' 6" 51' 54' 6 6" 20" 28' 6" 30' 7' 57' 60' 7 3" 24" 34' 36' 8' 68' 72' 8 3" 30" 40' 42' 10' 80' 84' 10 0" Note The valve allowance given is the total amount of additional cable to be installed on the valve. If multiple tracers are used, total valve allowance may be divided among the individual tracers. The total valve allowance may be alternated among tracers for multiple valves in a heat trace circuit. Allowances are for 150 pound valves. More cable is required for higher rated valves. Refer to heat trace isometric drawing for project specific allowances. Serpentined on Pump Serpentined on Valve Circuit Layout on Valve 4 Circuit Layout on Pump
6 Completing the Installation Begin final cable attachment by securing the end-of-circuit termination kit and working back toward the power supply. Refer to Illustration I. Flexible heating cables are to be installed using attachment tape. Circumferential bands of tape should be installed at 12 (30 cm) intervals to keep the cable in proper contact with the pipe. Refer to Table 2 below to calculate the number of rolls of attachment tape required based on the pipe diameter 1. If applicable, refer to installation details provided with the project drawings or contact Thermon for additional information regarding installation. 2. In addition to the circumferential tape requirements, a continuous covering of aluminum foil tape may be required when: Spray or foam 2 thermal insulation is applied. Heat tracing nonmetallic piping. 3. Complete splice connections (if required) in accordance with the installation instructions provided with the splice kit. 4. Before making power connections, The heating cable should be tested to ensure electrical integrity with at least a 500 Vdc megger between the heating cable bus wires and the heating cable metallic braid. IEEE 515 recommends that the test voltage for polymer insulated heating cables be 2500 Vdc. Minimum resistance should be 20 megohms. (Record 2 on Cable Testing Report.) 5. Install power connection kit in accordance to the detailed installation instructions provided with the kit. 6. Secure temperature sensor (if required) to pipe utilizing attachment tape. Locate temperature sensor as shown on page 6. Notes Table 2 assumes circumferential bands every 12 (30 cm) along the length of the process piping. 2. Verify exposure temperature of heating cable versus curing temperature of insulation. Illustration I: Final Cable Attachment Proposed End of Circuit Proposed Power Supply Tape Length Table 2: (Value Represents Approximate Linear Pipe Length Allowance Per Roll) Pipe Diameter in Inches ½"-1" 1¼" 1½" 2" 3" 4" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36 yd 130' 115' 110' 95' 75' 65' 50' 40' 35' 30' 26' 23' 21' 19' 16' 13' 60 yd 215' 195' 180' 160' 125' 105' 80' 65' 55' 50' 43' 38' 35' 31' 27' 22' 5
7 Final Connections Follow the circuit fabrication instructions for the specific cable type. Power connection and end-of-circuit termination kits are designed for each type of cable; substitutions should not be made. 2. For ambient controlled power, the heating circuit should be connected directly to the switched power feed wiring. L1 L2/N 3. For pipewall sensing thermostatic control, the heating circuit is to be connected in series with the control contacts as shown below. The pipewall sensing thermostat may require more than one support point. L1 L2/N CB Heat Tracing Junction Box CB Heat Tracing Junction Box NO NC COM (SPDT Thermostat Shown) NO COM Ambient Sensing Thermostat Heater Pipewall Sensing Thermostat NC Thermostat Sensor Thermal Insulation The need for properly installed and well-maintained thermal insulation cannot be overemphasized. Without insulation, heat losses are generally too high to be offset by a conventional heat tracing system. 2. In addition to piping and in-line equipment such as pumps and valves, all heat sinks must be properly insulated. This includes pipe supports, hangers, flanges and, in most cases, valve bonnets. 3. Regardless of the type or thickness of insulation used, a protective barrier should be installed. This protects the insulation from moisture intrusion, physical damage and helps ensure the proper performance of the heat tracing system. Seal around all penetrations through the thermal insulation. 4. After the installation of the thermal insulation and weather barrier but BEFORE ENERGIZING THE HEATING CIRCUIT, the megohmmeter test should be repeated. This should call attention to any damage to the heating cable that may have occurred during the insulation installation. (Record 3 on Cable Testing Report) 5. Apply caution labels to insulation weather barrier at required intervals along pipe Final Inspection and Documentation It is recommended that the circuit be temporarily energized so that the volts, amps, pipe temperature and ambient temperature may be recorded. This information may be of value for future reference and should be maintained for the historical operating data log (Record 4 on Cable Testing Report). 2. Stabilized design can be used for self-regulating heating cables to assign a lower T-class through the use of the Thermon CompuTrace software or Thermon Engineering. 3. Stabilized design can be used for power-limiting and constant watt heating cables without a limiting device to determine the T-class through the use of the Thermon Compu- Trace software or Thermon Engineering. 4. A sample historical operating data log form is included in the Electric Heat Tracing Maintenance and Troubleshooting Guide, Thermon Form TEP0066). Heater (SPDT Thermostat Shown) The National Electric Code and Canadian Electrical Code require ground-fault protection be provided for branch circuits supplying electric heat tracing. 6
8 Cable Testing Report 1. Refer to Thermon Installation Procedures, FORM PN 50207, for general installation procedures, requirements and guidelines. 2. Upon receiving heating cable, check the cable to make sure the proper type and output have been received. All flexible cables have the catalog number, voltage rating and watt output printed on the outer jacket. 3. Visually inspect cable for any damage incurred during shipment. The heating cable should be tested to ensure electrical integrity with at least a 500 Vdc megger between the heating cable bus wires and the heating cable metallic braid. IEEE 515 recommends that the test voltage for polymer insulated heating cables be 2500 Vdc. Minimum resistance should be 20 megohms. (Record 1 on Cable Testing Report.) A. Connect the positive lead of the megger to the cable bus wires. B. Connect the negative lead of the megger to the metallic braid. C. Energize the megger and record the reading. Readings between 20 megohms and infinity are acceptable. Readings below 20 megohms may mean the electrical insulation has been damaged. Recheck the heating cable for physical damage between the braid and the heating element; small cuts or scuffmarks on the outer jacket will not affect the megger reading unless there was actual penetration through the braid and dielectric insulation jacket. 4. Once the installation is complete, but prior to installation of thermal insulation, recheck the heating cable with at least a 500 Vdc megger between the heating cable bus wires and the heating cable metallic braid. IEEE 515 recommends that the test voltage for polymer insulated heating cables be 2500 Vdc should be 20 megohms. (Record 2 on Cable Testing Report.) 5. After the thermal insulation is installed, the megohmmeter test should be repeated. Minimum resistance should be 5 megohms. (Record 3 on Cable Testing Report.) 6. After the thermal insulation is installed and power supply is completed, record the panel and circuit breaker information. Ensure all junction boxes, temperature controllers, cable glands, etc. are properly secured. Set the temperature controller (if applicable) to the manual setting and apply rated voltage to the heat tracing circuit(s) for 5 minutes. Record the ambient temperature, measure and record the circuit(s) voltage and current. (Record 4 on Cable Testing Report.) NOTE: To ensure the heating cable warranty is maintained through installation, the testing outlined on this sheet must be completed on the installed heating cables, and the test results recorded and mailed/faxed to: Thermon Customer Service 100 Thermon Drive San Marcos, Texas Fax:
9 Cable Testing Report make additional copies as required for each circuit. Customer: Contractor: Address: Address: Phone No: Project Reference: Record 1: Prior to Installation Cable Type: Reel Length: Reel Number: Insulation Resistance M Ohms: Tested By: Witnessed By: Record 2: After Installation of Insulation Resistance M Ohms: Heater Length: Heater Number: Tested By: Witnessed By: Record 3: After The Thermal Insulation Is Installed Insulation Resistance M Ohms: Tested By: Witnessed By: Record 4: Final Commissioning Panel Number: Breaker Number: Volts: Ambient Temperature (deg. F): Pipe Temperature (deg. F): Recorded Amps (After 5 Min.): Tested By: Witnessed By: Phone No. 8
10 THERMON... The Heat Tracing Specialists 100 Thermon Dr. PO Box 609 San Marcos, TX Phone: Facsimile: HEAT In Canada call For the Thermon office nearest you visit us at... Specifications and information are subject to change without notice. Form PN
Electric Heat Tracing INSTALLATION PROCEDURES
INSTALLATION PROCEDURES Complete Electric Heat Tracing System... Types of Heating Cables 1... Self-Regulating Heating Cables: BSX (refer to Form TEP0067U) 1725 II 2 G & D Ex e II T5 or T6 DEMKO 02ATEX0132424,
MIQ TM Mineral Insulated Heating Cable INSTALLATION PROCEDURES. (North America)
MIQ TM Mineral Insulated INSTALLATION PROCEDURES (North America) MIQ TM Mineral Insulated The following installation procedures are suggested guidelines for the installation of a Thermon MIQ mineral insulated
SnoTrace KSR Surface Snow and Ice Melting INSTALLATION PROCEDURES
SnoTrace Surface Snow and Ice Melting INSTALLATION PROCEDURES SnoTrace INSTALLATION PROCEDURES Refer to the SnoTrace Cable Testing Report for required recording of test data and circuit information. Upon
TubeTrace, ThermoTube
TubeTrace, ThermoTube and Custom CEMS Tubing Bundles INSTALLATION PROCEDURES English Units TubeTrace & ThermoTube Tubing Bundles Receiving, Storing and Handling... 1. Inspect materials for damage incurred
Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE
Type FLX Freezer Floor Frost Heave Protection DESIGN GUIDE Commercial Products Type FLX TM Freezer Floor Frost Heave Protection DESIGN GUIDE Contents Introduction...2 Application Information... 2-3 Product
BSX TM. Self-Regulating Heating Cable. Product Specifications
BSX TM Freeze Protection or Process Temperature Maintenance BSX self-regulating heating cables are designed to provide freeze protection or process temperature maintenance to metallic and nonmetallic piping,
SCTK INSTALLATION PROCEDURES. Splice Connection Termination Kit. SCTK-1D for BSX, RSX, VSX SCTK-2D for KSX, HTSX SCTK-3D for HPT, FP
Splice Connection Termination Kit SCTK-D for BSX, RSX, VSX SCTK-D for KSX, HTSX SCTK-D for HPT, FP To be used in conjunction with Thermon Connection kits Receiving, Storing and Handling.... Inspect materials
Complex Piping Design Guide for Self-Regulating Heating Cables
Complex Piping Design Guide for Self-Regulating Heating Cables Introduction... 4 Computer Aided Design Program... 4 Heat Tracing Design Outline... 5 Basis for a Good Design... 5-14 Step 1: Establish Design
Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration
SELF-REGULATING PIPE TRACING HEATER CABLE
SELF-REGULATING PIPE TRACING HEATER CABLE Installation & Operation Manual TABLE OF CONTENTS GENERAL INFORMATION... 1 How Heating Systems Work...1 PRODUCT SELECTION... 1 RECEIPT & STORAGE... 1 Receipt...1
Pipe Freeze Protection Design/Install Guide
Pipe Freeze Protection Design/Install Guide Page 1 of 16 Pipe Freeze Protection Design / Install Guide CONTENTS Introduction Page 3 STEP 1 Information Required Page 4 STEP 2 Design Considerations Page
FAK-7HTS High Temperature Tubing Bundle End Seal Kit INSTALLATION PROCEDURES
High Temperature End Seal Kit The following installation procedures are suggested guidelines for the installation of the FAK-7HTS High Temperature Tubing Bundle End Seal Kit. Receiving, Storing and Handling...
Installation Instructions. Industrial Heating Cable Products
Installation Instructions Industrial Heating Cable Products PJ438-21 161-057884-001 September, 2014 Important General Instructions These instructions are to be followed when installing Chromalox Heating
KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES
KSR-SK-DB In-Line Splice Kit KSR Snow Melting Cable INSTALLATION PROCEDURES KSR-SK-DB The following installation procedures are suggested guidelines for the installation of in-line cable splices. They
Self-Regulating Low Temperature Heating Cable
PDS SRL Self-Regulating Low Temperature Heating Cable Self-Regulating, Energy Efficient 16 AWG Buss Wire Circuit Lengths to 660 Feet Process Temperature Maintenance to 150 F (65 C) Maximum Continuous Exposure
Heat Tracing for the Refrigeration Industry
Heat Tracing for the Refrigeration Industry THERMON trace heating cables THERMON self regulating trace heaters cover the complete range of applications from frost protection to high temperature industrial
Installation, Operation and MAINTENANCE INSTRUCTIONS. Industrial Heating Cable Products IMPORTANT GENERAL INSTRUCTIONS
Chromalox Installation, Operation and MAINTENANCE INSTRUCTIONS DIVISION 4 SALES REFERENCE DATE SERVICE REFERENCE (Supersedes PJ438-16) JULY, 2010 SECTION RT PJ438-18 161-057884-001 Industrial Products
Frost Heave Protection System Installation and Operation Manual for Self-Regulating Heating Cable Systems
Frost Heave Protection System Installation and Operation Manual for Self-Regulating Heating Cable Systems FHP Self-regulating Heating Cable Systems 1 / 17 WARNING: Fire and Shock Hazard Raychem frost heave
Pictorial Index... A-14 Introduction to Heat Trace Cable Systems... 6-2 Installation Examples... 6-3 Engineering Guide... 6-4 Heat Loss Tables...
Pictorial Index....................... A-14 Introduction to Heat Trace Cable Systems............... 6-2 Installation Examples................... 6-3 Engineering Guide..................... 6-4 Heat Loss
Heat Tracing Sales Mt. Airy, Maryland www.heattracingsales.com 410-795-2223. Installation Instructions
Chromalox Installation Instructions DIVISION 4 SALES REFERENCE DATE SERVICE REFERENCE SECTION DTS (Supersedes PJ944-5) PJ944-6 161-562581-049 MARCH, 2012 DTS-HAZ For Use With Self-Regulating & Constant
Installation & Maintenance
Installation & Maintenance SELF-REGULATING HEATER CABLE CONTENTS GENERAL INFORMATION... 4 How Heating Systems Work...4 PRODUCT SELECTION... 4 RECEIPT & STORAGE... 4 Receipt...4 Storage...4 Withdrawal from
Heating Cable. Construction
Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant
Sizing Circuit Breakers for Self-Regulating Heat Tracers
Sizing Circuit Breakers for Self-Regulating Heat s Effective Resistance (ohm/m) Introduction Circuit breaker sizing for S/R tracers is quite easily accomplished by using the specification sheet data or
Industrial Heat Tracing INSTALLATION AND MAINTENANCE MANUAL FOR MINERAL INSULATED CABLE SYSTEMS APPLIED TO PIPES AND VESSELS
Industrial Heat Tracing INSTALLATION AND MAINTENANCE MANUAL FOR MINERAL INSULATED CABLE SYSTEMS APPLIED TO PIPES AND VESSELS INDUSTRIAL HEAT TRACING SOLUTIONS WWW.PENTAIRTHERMAL.COM Important Safeguards
RayClic Connection System Installation Instructions
F M -W RayClic Connection System Installation Instructions RayClic WARNING: Shock Hazard 718K Pipe Heating Cable with HWAT, IceStop, also Listed De-icing and and XL-Trace heating Snow Melting Equipment
WarmTrace TM INSTALLATION INSTRUCTIONS. Systems for Hot Water Temperature Maintenance. Systems for Hot Water Temperature Maintenance
WarmTrace TM INSTALLATION INSTRUCTIONS Commercial Products INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS LIC SMK2408 Contents Safety Precautions... 2 Using the Guide... 2 Recieving and Storing Cable...
Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables
Installation Instructions DTS-HAZ DTS-HAZ-DC for Use with Self-Regulating & Constant Wattage Heating Cables PJ944-9 5625-81049 May 2013 1 2 DTS-HAZ Self-Regulating & Constant Wattage Heating Cables Junction
DTS-HAZ DTS-HAZ-DC. Installation Instructions. for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables
Installation Instructions DTS-HAZ DTS-HAZ-DC for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables 1 PJ944-10 5625-81049 May 2015 2 DTS-HAZ & DTS-HAZ-DC 1 2 3 8 12
Mineral Insulated Heating
Self-Regulating Mineral Insulated cables This section provides an overview and general design guidelines for mineral insulated heat-tracing systems. For complete design assistance, contact your Pentair
Self-Regulating Pipe Tracing Heating Cable Specification/Application Guide. Polyolefin. Performance and Rating Data
TSR Self-Regulating Pipe Tracing Heating Cable Specification/Application Guide READ CAREFULLY PRINCIPLE OF OPERATION Easy Heat TSR is a self-regulating heating cable that automatically varies its heat
Nelson MI Cable is a high performance, industrial grade heat tracing cable used for applications requiring:
Alloy 825 Sheath Custom Fabricated Heating Elements Magnesium Oxide Insulation Description: Mineral insulated cable is a metal sheathed cable that uses a metallic conductor as the heating element. The
XL-Trace System Installation and Operation Manual
XL-Trace System Installation and Operation Manual Pipe freeze protection and flow maintenance WARNING: Fire and shock hazard. This heat-tracing system must be installed correctly to ensure proper operation
Industrial Heat-Tracing Installation and Maintenance Manual
Industrial Heat-Tracing Installation and Maintenance Manual Self-Regulating and Power-Limiting Heating Cable Systems WARNING: Fire and shock hazard. Raychem heat-tracing systems must be installed correctly
RayClic Connection System Installation Instructions
RayClic Connection System Installation Instructions Description RayClic-S Splice Kit RayClic-T Tee and End Seal Kit RayClic-X Cross and End Seal Kit These kits are for use with Raychem IceStop, XL-Trace
4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
Mineral Insulated Heater Cable. Installation & Operation Manual
Mineral Insulated Heater Cable Installation & Operation Manual CONTENTS general information...1 How Heating Systems Work...1 PrOduct selection...1 RECEIPT & STORAGE...1 PIPE LENGTH VERFICATION...1 DRAWINGS...2
RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
NELSON HEAT TRACING SYSTEMS
DESCRIPTION The HASK-P Hazardous Area Seal Kit provides the cable termination and explosion proof seal parts needed to make the power end electrical connections associated with Nelson Heat Tracing Systems
Design, Installation and Maintenance Manual
The Heat Tracing Authority TM Design, Installation and Maintenance Manual Industrial Electric Heat Tracing Systems CONTENTS Page SYSTEM DESIGN... 1 Introduction; Competence; Thermal Insulation; Selection
Operating Instructions
CS101 CarSense Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for
Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems
Pipe and Equipment Insulations Zeston PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems Zeston PVC Insulated Fitting Covers Installation Instructions for Hot,
Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation
Heat Trace Fundamentals Monte Vander Velde, P.E. President, Interstates Instrumentation Contents Introduction... 3 Purpose of Heat Trace... 3 Types of Heat Trace... 4 Steam Trace vs. Electric Trace...
Installation Instructions SELF-REGULATING (SR) ROOF AND GUTTER DE-ICING CABLES INDUSTRIAL AND COMMERCIAL SERIES
Installation Instructions SELF-REGULATING (SR) ROOF AND S INDUSTRIAL AND COMMERCIAL SERIES CONTENTS page SECTION 1. OVERVIEW 1.1 Precautions...164 1.2 Cable and components...164 1.3 General accessories...164
Electric Water Heater
Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.
Series 510 Submersible Level Transmitters
Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable
COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES
COLD LEAD OPTIONS FOR XMI MINERAL INSULATED (MI) HEATING CABLES PRODUCT OVERVIEW XMI with standard MI cold lead and Type X connector MI cable heated section PRODUCT OVERVIEW XMI with PyroFLX cold lead
Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)
Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
Protection Systems. A UTC Fire & Security Company F-73-01. Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS
Effective: May 2007 AlarmLine TM R Protection Systems Linear Heat Detector A UTC Fire & Security Company F-73-01 FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm Set
COATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown
Self-Regulating 920 Series Dual-point heat-tracing control system Power-Limiting Mineral Insulated 920*E4FWL*SIS302*SS3102 shown Product overview The DigiTrace 920 is a compact, full-featured, microprocessor-based,
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
How To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
Screw Plug Immersion Heaters
Immersion Heaters Overview Immersion Heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal enclosures for electrical connections. Immersion Heaters
RVR Hybrid System Installer Instructions - 10052012. RVR Hybrid System Controller Installation Instructions
RVR Hybrid System Controller Installation Instructions 1 Introduction to Hybrid Systems The RVR Hybrid system uses a combination of the Immergas Audax range of heat pumps with gas or oil boilers to create
PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM
PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM RELIANCE Has Everything Your Customers Need to Do the Job Right! Reliance Water Heater Company was founded in 1981 to provide a water heater
STAR PIPE Polska S.A ul. Gdyńska 51 62-004 Czerwonak tel. +48 61 667 41 20 fax +48 61 667 41 38
THE ALARM SYSTEM The base of the system consists of two non-insulated copper alarm wires with section equal to 1.5 mm2, located inside polyurethane foam parallel to the conduit pipe, offset in relation
OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE
OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659 FAX: (203)
National Craft Assessment and Certification Program S P E C I F I C A T I O N S
National Craft Assessment and Certification Program S P E C I F I C A T I O N S INDUSTRIAL ELECTRICIAN V4 ELEC26_O4 Released September 2013 Focus Statement An Industrial Electrician must be able to interpret
Ducoterra Radiant Heating Panel Installation Manual
Ducoterra Radiant Heating Panel Installation Manual 1. Introduction Your new radiant heating panels are designed to heat living and working spaces rapidly and efficiently by radiant heating. Like the sun,
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
TC 1818a. Operating Guide. Control Module SWM-015.5
TC 1818a Control Module Operating Guide SWM-015.5 This guide is intended solely for use by owners of Thermon HeatChek TM heat tracing control and monitoring units. This manual describes operation for TC
Sanitary and CIP Toroidal Sensor
Instruction Sheet PN 51A-225/rev.I December 2010 Model 225 Sanitary and CIP Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
PRODUCT / APPLICATION INFORMATION
Abstract This paper will discuss performance life testing and stability testing used for self-regulating heating cables. It will show how the techniques were developed and evolved from the 970 s to the
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
ELECTRIC HEATER COMPANY Operating and Maintenance Manual For Immersion Heating Elements
ELECTRIC HEATER COMPANY Operating and Maintenance Manual For Immersion Heating Elements HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203) 378-2659 FAX: (203) 378-3593 INTERNET:
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
RTB Tubing Bundles Installation Guide Heating solutions for instrument and small-diameter process lines
RTB Tubing Bundles Installation Guide Heating solutions for instrument and small-diameter process lines 1 / 20 WARNING: Fire and shock hazard. Raychem heat-tracing systems must be installed correctly to
Operating Instructions
VMD202 Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the VMD202 as a safety reversing or presence detection system. The VMD202 requires that a vehicle be moving for detection.
Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants
Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants PG&E Office San Francisco January 18, 2007 Craig K. Meier Corrosion Control Incorporated Corrosion process for tanks
BB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Heat Pump Water Heater IOM Manual
Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump
CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping
BUILDING TECHNOLOGIES PROGRAM Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping The intent of the pipe insulation requirements is to reduce temperature changes
Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY.
Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY. Air Pressure 586.1 min 689.5 kpa max [85 min 100 psi max] Air Displacement 721,000 mm 3 [44 in. 3 ] Figure 1 Weight
DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS
DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS A. SCOPE 1. This information is intended to assist contractors, installers and code officials in the proper design and installation of flexible
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION
SECTION 230713- ALUMAGUARD ENGINEER SPECIFICATION DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
ECOplus Solar Cylinder
TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes
Chromalox PRECISION HEAT AND CONTROL. Electrical Heat Tracing Systems Design Guide
Chromalox PRECISION HEAT AND CONTROL Electrical Heat Tracing Systems Design Guide INTRODUCTION TABLE OF CONTENTS TABLE OF CONTENTS Thermal Design - Pipes:.. 1 Thermal Design - Tanks:.. 6 Heating Cable
ALARMLINE ANALOGUE Linear Heat Detection System
ALARMLINE ANALOGUE Alarmline Analogue sensor cable senses temperature variations by continuously monitoring the resistance of specially doped N.T.C. polymeric insulation. A change in temperature produces
A. Shop Drawing submittals shall include, but not be limited to, the following:
SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.
Light Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
Toroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always
INSTRUKTIONSMANUAL INSTALLATION INSTRUCTION
FROSTSIKRINGSKABEL M/ TERMOSTAT IPX7 NO-FROST HEATING CABLE W/THERMOSTAT IPX7 INSTRUKTIONSMANUAL INSTALLATION INSTRUCTION 2 M: Art nr 600002 EAN nr 5709133560041 4 M: Art nr 600004 EAN nr 5709133560058
KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET
1 KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET KI XL - 03 / KI-SC 10 TWO COMPONENT AMBIENT CURABLE POLYETHYLENE COMPOUND FOR INSULATION OF LOW VOLTAGE POWER CABLE DESCRIPTION : KI polyethylene compound
Contact Information: 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance.
Technical Data Sheet & Installation Instructions for 4031-0001 Electrical Connection Kit for CL Series Constant Wattage Temptrace for Low Temperature Maintenance Bulletin CL-II Contact Information: Parker