Professional Report. Map section. Location of the system. Valkkinen Longitude: Latitude: Elevation: 89 m
|
|
|
- Roxanne Douglas
- 10 years ago
- Views:
Transcription
1 Puulämmitys 6 x SF3 Location of the system Map section Valkkinen Longitude: Latitude: Elevation: 89 m This report has been created by: Samppa Takala Samppa Takala Nyrhintie Pori [email protected] Comments on the project Sundial Finland Oy 1 / 8 V / / 21:38:24
2 System overview (annual values) Total fuel and/or electrical energy consumption of the system [Etot] Total energy consumption [Quse] System performance (Quse / Etot) 0.94 Comfort demand 20,831.8 kwh 19,489 kwh Energy demand for domestic hot water not met Overview solar thermal energy (annual values) Collector area 13.2 m² Solar fraction total 32.9% Solar fraction hot water [SFnHw] 47.4 % Solar fraction building [SFnBd] 22.1 % Total annual field yield 7,051 kwh Collector field yield relating to gross area kwh/m²/year Collector field yield relating to aperture area kwh/m²/year Max. fuel savings 2,256.3 kg: [Firewood] Max. energy savings 9,401.3 kwh Max. reduction in CO2 emissions kg Solar fraction: fraction of solar energy to system [SFn] Horizon line Meteorological data-overview Average outdoor temperature 4.7 C Global irradiation, annual sum kwh/m² Diffuse irradiation, annual sum 425 kwh/m² 2 / 8 V / / 21:38:24
3 Component overview (annual values) Boiler Firewood 50kW Power kw 50 Total efficiency % 69.3 Energy from/to the system [Qaux] kwh 14,403.8 Fuel and electrical energy consumption [Eaux] kwh 20,782.6 Energy savings solar thermal kwh 9,401.3 CO2 savings solar thermal kg Fuel savings solar thermal kg 2,256.3 Collector Sundial SF3 - DS Data Source u Number of collectors 6 Number of arrays 1 Total gross area m² 13.2 Total aperture area m² 12 Total absorber area m² 12 Tilt angle (hor.=0, vert.=90 ) 40 Orientation (E=+90, S=0, W=-90 ) 0 Collector field yield [Qsol] kwh 7,051 Irradiation onto collector area [Esol] kwh 14,004.3 Collector efficiency [Qsol / Esol] % 50.3 Direct irradiation after IAM kwh 7,943.8 Building - Heated/air-conditioned living area m² 150 Heating setpoint temperature C 20 Heating energy demand excluding DHW [Qdem] kwh 12,500 Annual specific heating energy demand kwh/m² 83.3 Useful heat gain kwh 12,499.9 Total energy losses kwh 25,000 Heating element Floor heating Floor heating Number of heating/cooling modules - 8 Power per heating element under standard conditions W 1,000 Nominal inlet temperature C 40 Nominal return temperature C 35 Net energy from/to heating/cooling modules kwh 12,490.5 Hot water demand Constant Volume withdrawal/daily consumption l/d Temperature setting C 58 Energy demand [Qdem] kwh 7, / 8 V / / 21:38:24
4 Pump Solar loop pump Eco, medium Circuit pressure drop bar Flow rate l/h 180 Fuel and electrical energy consumption [Epar] kwh 42 Pump Space heating loop pump Eco, small Circuit pressure drop bar Flow rate l/h Fuel and electrical energy consumption [Epar] kwh 7.3 Storage tank l combi for heat pumps Volume l 2,500 Height m 2 Material Steel Insulation Rigid PU foam Thickness of insulation mm 80 Heat loss kwh Connection losses kwh Loop Solar loop Fluid mixture Propylene mixture Fluid concentration % 33.3 Fluid domains volume l 42.9 Pressure on top of the circuit bar 4 Solar thermal energy to the system [Qsol] kwh 4 / 8 V / / 21:38:24
5 Heat generator energy to the system (solar thermal energy not included) [Qaux] kwh Solar fraction: fraction of solar energy to system [SFn] % Total fuel and/or electrical energy consumption of the system [Etot] kwh 5 / 8 V / / 21:38:24
6 Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Solar thermal energy to the system [Qsol] kwh Heat generator energy to the system (solar thermal energy not included) [Qaux] kwh Heat generator fuel and electrical energy consumption [Eaux] kwh Solar fraction: fraction of solar energy to system [SFn] % Total fuel and/or electrical energy consumption of the system [Etot] kwh Irradiation onto collector area [Esol] kwh Electrical energy consumption of pumps [Epar] kwh Total energy consumption [Quse] kwh Heat loss to indoor room (including heat generator losses) [Qint] kwh Heat loss to surroundings (without collector losses) [Qext] kwh / 8 V / / 21:38:24
7 Collector Daily maximum temperature [ C] 7 / 8 V / / 21:38:24
8 Energy flow diagram (annual balance) 8 / 8 V / / 21:38:24
8ah: 2xBlue-B ST300L 2.919MW SF56.5% 225L/D. 2,391.9 kwh
Solar Colwood 2013 8ah: 2xBlue-B ST300L 2.919MW SF56.5% 225L/D Location of the system Canada Victoria Longitude: -123.37 Latitude: 48.42 Elevation: 40 m This report has been created by: MD Miroslav Danielka
Professional Report. US Solar Network Evanston residential DHW. 1 Gobi 410 001 Helio-Pak 2-4 persons. Map section. Location of the system
US Solar Network Evanston residential DHW 1 Gobi 410 001 Helio-Pak 2-4 persons Location of the system Map section Evanston, IL Longitude: -87.694 Latitude: 42.055 Elevation: 597 ft This report has been
Map section. 87,390 kbtu
Closed-loop Solar System Closed-loop Solar Preheat with Back-Up Heater Location of the system Map section Richmond Longitude: -77.52 Latitude: 37.582 Elevation: 217 ft This report has been created by:
AT&T Global Network Client for Windows Product Support Matrix January 29, 2015
AT&T Global Network Client for Windows Product Support Matrix January 29, 2015 Product Support Matrix Following is the Product Support Matrix for the AT&T Global Network Client. See the AT&T Global Network
Energy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
Yield Reduction due to Shading:
1x4 1x16 10 x CBC Energy A/S x Danfoss Solar Inverters CBC-40W Poly 40 W TLX 1,5k 5 ; 1x11 3x4 0 1,5kW 1536 x CBC Energy A/S 1 x Power-One CBC-40W Poly 40 W TRIO-7,6-TL-OUTD 30 ; 4x14 0 7,6kW Location:
COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*
COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) 2 Fixed Rates Variable Rates FIXED RATES OF THE PAST 25 YEARS AVERAGE RESIDENTIAL MORTGAGE LENDING RATE - 5 YEAR* (Per cent) Year Jan Feb Mar Apr May Jun
COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*
COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) 2 Fixed Rates Variable Rates FIXED RATES OF THE PAST 25 YEARS AVERAGE RESIDENTIAL MORTGAGE LENDING RATE - 5 YEAR* (Per cent) Year Jan Feb Mar Apr May Jun
Case 2:08-cv-02463-ABC-E Document 1-4 Filed 04/15/2008 Page 1 of 138. Exhibit 8
Case 2:08-cv-02463-ABC-E Document 1-4 Filed 04/15/2008 Page 1 of 138 Exhibit 8 Case 2:08-cv-02463-ABC-E Document 1-4 Filed 04/15/2008 Page 2 of 138 Domain Name: CELLULARVERISON.COM Updated Date: 12-dec-2007
Field test of a novel combined solar thermal and heat pump system with an ice store
Field test of a novel combined solar thermal and system with an ice store Anja Loose Institute for Thermodynamics and Thermal Engineering (ITW), Research and Testing Centre for Thermal Solar Systems (TZS),
Analysis One Code Desc. Transaction Amount. Fiscal Period
Analysis One Code Desc Transaction Amount Fiscal Period 57.63 Oct-12 12.13 Oct-12-38.90 Oct-12-773.00 Oct-12-800.00 Oct-12-187.00 Oct-12-82.00 Oct-12-82.00 Oct-12-110.00 Oct-12-1115.25 Oct-12-71.00 Oct-12-41.00
Gross/Active PV Surface Area: 13.094,40 / 13.086,29 m². Energy Produced by PV Array (AC):
1x17 1x17 1x 8 x Trina Solar Trina TSM-PC5A 6 6 W 5 ; x Danfoss Solar Inverters TLX 1,5k 1,5kW Location: Arrondissement d'issoire Climate Data Record: Arrondissement d'issoire PV Output:.8, kwp Gross/Active
PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
Daikin Altherma Hybrid Heat Pump
your comfort. our world. Daikin Altherma Hybrid Heat Pump The natural combination Heating Integrated Solutions Ventilation Air Conditioning Refrigeration About Daikin Forward thinking... Daikin has a worldwide
Enhanced Vessel Traffic Management System Booking Slots Available and Vessels Booked per Day From 12-JAN-2016 To 30-JUN-2017
From -JAN- To -JUN- -JAN- VIRP Page Period Period Period -JAN- 8 -JAN- 8 9 -JAN- 8 8 -JAN- -JAN- -JAN- 8-JAN- 9-JAN- -JAN- -JAN- -JAN- -JAN- -JAN- -JAN- -JAN- -JAN- 8-JAN- 9-JAN- -JAN- -JAN- -FEB- : days
The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.
MSV: Square Footage: 24,844 No. of Floors: 1 Year Built: 1963 Type of Use: Lounge and dining area open all night for snacks Steam Water-cooled condenser, 50-Ton York unit with a 6 cylinder-reciprocating
PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)
PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Dept. Building Environment Science &Technologies Politecnico di Milano Italy Research funded
FREE ONLINE APPLICATION OF CALCULATION
HELPS YOU TO CALCULATE, OF RAPID AND EASY WAY, AN ISOLATED PHOTOVOLTAIC SOLAR, LOCATED IN ANY PART OF PLANET. FREE ONLINE APPLICATION OF CALCULATION EXAMPLE 4: CALCULATION OF SOLAR PHOTOVOLTAIC INSTALLATION
Hot Water. Heat pump water heaters. Residential and Commercial R410a
Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating
Solar District Heating with Seasonal Thermal Energy Storage in Germany
Solar District Heating with Seasonal Thermal Energy Storage in Germany Dipl.-Ing. Thomas Pauschinger Steinbeis Research Institute for Solar and Sustainable Thermal Energy Systems Meitnerstr. 8 70563 Stuttgart,
Daikin Altherma Hybrid Heat Pump
your comfort. our world. Daikin Altherma Hybrid Heat Pump Smart heating technology for the best of both worlds Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Forward thinking About
Daikin Altherma Hybrid Heat Pump
Daikin Altherma Hybrid Heat Pump Smart technology for the best of both worlds NATIONAL HEAT PUMP 19 JUNE 2014 ICC BIRMINGHAM WINNER Forward thinking Now is the time to rethink the way we heat our homes
Design of Grid Connect PV systems. Palau Workshop 8 th -12 th April
Design of Grid Connect PV systems Palau Workshop 8 th -12 th April INTRODUCTION The document provides the minimum knowledge required when designing a PV Grid connect system. The actual design criteria
Subtropical Cities September 2006. Design for Energy Efficiency in Commercial Buildings in Queensland
Subtropical Cities September 2006 Design for Energy Efficiency in Commercial Buildings in Queensland Contents Typical Building Constraints & Requirements Understanding Energy Consumption in Buildings HVAC
CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid
CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid BIOS BIOENERGIESYSTEME GmbH, Austria TEL.: +43 (316)
ECOplus Solar Cylinder
TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes
Models and Methods in Applied Sciences
Energy consumption and energy saving in Malaysian office buildings S.Sadrzadehrafiei, K.Sopian S.Mat, C.Lim Solar Energy Research Institute University Kebangsaan Malaysia 43600, Bangi, Malaysia [email protected],
Sino-Italian Environment & Energy Building S I E E B
MOST Ministry of Science and Technology Republic of China Sino-Italian Environment & Energy Building S I E E B Concept The Sino-Italy Environment & Energy Building (SIEEB) is an intelligent, ecological
Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.
Codes and High Performance Hot Water Systems Gary Klein Affiliated International Management, LLC 916 549 7080 [email protected] Annual Energy Use for Heating Water Natural Gas Gallons Per Day
Solar Thermal Systems
Solar Thermal Systems Design and Applications in the UAE Murat Aydemir Viessmann Middle East FZE General Manager (M.Sc. Mech.Eng., ASHRAE) Dubai Knowledge Village Congress Centre, Dubai 20.4.2009 Viessmann
Solar chilled drinking water sourced from thin air: modelling and simulation of a solar powered atmospheric water generator
20th International Congress on Modelling and Simulation, Adelaide, Australia, 1 6 December 2013 www.mssanz.org.au/modsim2013 Solar chilled drinking water sourced from thin air: modelling and simulation
The Central Solar Heating Plant with Aquifer Thermal Energy Store in Rostock - Results after four years of operation
The Central Solar Heating Plant with Aquifer Thermal Energy Store in Rostock - Results after four years of operation Thomas Schmidt 1), Hans Müller-Steinhagen 1)2)3) 1) Solar- und Wärmetechnik Stuttgart
Hybrid heat pumps. saving energy and reducing carbon emissions
Hybrid heat pumps saving energy and reducing carbon emissions Bart Aspeslagh Product planning and new technology manager, Daikin Europe NV. [email protected] Stefanie Debaets Design engineer,
SOLEL SUNCOOLER SOLAR-POWERED AIR-CONDITIONING / HEATING SYSTEM
SOLEL SUNCOOLER SOLAR-POWERED AIR-CONDITIONING / HEATING SYSTEM organization / project coordinator (address, telephone, email) Solel Solar Systems Ltd./ Mr. Avi Brenmiller 3, Hac'shara St, Industrial Zone
ALONE. small scale solar cooling device Project No TREN FP7EN 218952. Project No TREN/FP7EN/218952 ALONE. small scale solar cooling device
Project No TREN/FP7EN/218952 ALONE small scale solar cooling device Collaborative Project Small or Medium-scale Focused Research Project DELIVERABLE D5.2 Start date of the project: October 2008, Duration:
Solar Energy Storage Critical Success Factors for Passive Houses in Ireland
Solar Energy Storage Critical Success Factors for Passive Houses in Ireland Shane Colclough, Dr Philip Griffiths, Dr Mervyn Smyth, Centre for Sustainable Technologies, University of Ulster, Newtownabbey,
Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc.
Maximizing Boiler Plant Efficiency Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc. Efficient Boiler Design Boiler Types Efficiency Definition Non-Condensing Condensing Maximizing Efficiency
A NEW CONCEPT OF A HYBRID STORAGE SYSTEM FOR SEASONAL THERMAL ENERGY STORAGE IN SOLAR DISTRICT HEATING
A NEW CONCEPT OF A HYBRID STORAGE SYSTEM FOR SEASONAL THERMAL ENERGY STORAGE IN SOLAR DISTRICT HEATING M. Reuß*, J.P. Mueller*, B. Roehle**, M. Weckler**, W. Schoelkopf** * Institut of Agric. Engineering,
Test Report No. C1319LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Thermics S.r.l. Via dell'olmo
Test Report No. C908LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Changzhou He Jia Solar Energy
Test Report No. C926LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: AMK-Collectra AG Bahnweg Nord
Sea Water Heat Pump Project
Sea Water Heat Pump Project Alaska SeaLife Center, Seward, AK Presenter: Andy Baker, PE, YourCleanEnergy LLC Also Present is ASLC Operations Manager: Darryl Schaefermeyer ACEP Rural Energy Conference Forum
THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power
THE EUROPEAN GREEN BUILDING PROGRAMME Technical Module on Combined Heat and Power Contents Foreword...1 1. Introduction...2 2. Inventory of the CHP system...3 3. Assessment of technical energy saving measures...5
Simulation Tools for Solar Cooling Systems Comparison for a Virtual Chilled Water System
Simulation Tools for Solar Cooling Systems Comparison for a Virtual Chilled Water System C. Bongs 1, A. Dalibard 2, P. Kohlenbach 3, O. Marc 4, I. Gurruchaga 5, P. Tsekouras 6 1 Fraunhofer Institute for
Ashley Institute of Training Schedule of VET Tuition Fees 2015
Ashley Institute of Training Schedule of VET Fees Year of Study Group ID:DECE15G1 Total Course Fees $ 12,000 29-Aug- 17-Oct- 50 14-Sep- 0.167 blended various $2,000 CHC02 Best practice 24-Oct- 12-Dec-
Natural geothermal energy.
ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.
Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX
Dallas/Fort Worth International Airport District Energy Plant Upgrades Project Making More with Less Sustainable Communities Conference Dallas, TX March 10, 2009 Agenda DFW Capital Development Program
R ENEWABLE SOURCES CSP. Sustainable and cost-efficient solar thermal energy
R ENEWABLE SOURCES CSP Sustainable and cost-efficient solar thermal energy 2 Turning environmental challenges into sustainable opportunities Feranova GmbH was founded in 2005 as a project development company
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
SDH ONLINE-CALCULATOR
CALCULATION PROGRAM FOR THE COST-BENEFIT ANALYSIS OF SOLAR DISTRICT HEATING SYSTEMS WWW.SDH-ONLINE.SOLITES.DE Dipl.-Ing. Thomas Schmidt and Dipl.-Ing. Laure Deschaintre Solites Steinbeis Research Institute
Computing & Telecommunications Services Monthly Report March 2015
March 215 Monthly Report Computing & Telecommunications Services Monthly Report March 215 CaTS Help Desk (937) 775-4827 1-888-775-4827 25 Library Annex [email protected] www.wright.edu/cats/ Last Modified
THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS
THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS James L. Hoff, VP of Research Center for Environmental Innovation in Roofing Tools and Models Tools require models
Sustainable water heating solutions through solar systems
VIESMANN Sustainable water heating solutions through solar systems Murat Aydemir Managing Director Viessmann Middle East FZE Viessmann is a Registered Provider with The American Institute of Architects
DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS
DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS DIETRISOL SOLAR WATER HEATING SYSTEMS NON-POLLUTING,
Solar Absorption Cooling / Heating System for the Intelligent Workplace
Solar Absorption Cooling / Heating System for the Intelligent Workplace Ming Qu Sophie Masson Dr. David Archer IWESS Workshop Oct.4,2006 page1 Introduction IW solar cooling/heating system One -axis solar
ROTEX gas hybrid heat pump. A strong team.
ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat
Direct Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
Energy Savings from Business Energy Feedback
Energy Savings from Business Energy Feedback Behavior, Energy, and Climate Change Conference 2015 October 21, 2015 Jim Stewart, Ph.D. INTRODUCTION 2 Study Background Xcel Energy runs the Business Energy
SONNENKLIMA package solution description
SONNENKLIMA package solution description Edited by: Daniel MUGNIER, Romain SIRE Version 1 SONNENKLIMA Perpignan, October 2009 Table of Contents 1 Introduction... 4 1.1 Increasing interest in air conditioning...
CENTERPOINT ENERGY TEXARKANA SERVICE AREA GAS SUPPLY RATE (GSR) JULY 2015. Small Commercial Service (SCS-1) GSR
JULY 2015 Area (RS-1) GSR GSR (LCS-1) Texarkana Incorporated July-15 $0.50690/Ccf $0.45450/Ccf $0.00000/Ccf $2.85090/MMBtu $17.52070/MMBtu Texarkana Unincorporated July-15 $0.56370/Ccf $0.26110/Ccf $1.66900/Ccf
150 Watts. Solar Panel. one square meter. Watts
Tool USE WITH Energy Fundamentals Activity land art generator initiative powered by art! 150 Watts 1,000 Watts Solar Panel one square meter 600 Watts SECTION 1 ENERGY EFFICIENCY 250 Watts 1,000 Watts hits
Presenter: Bruce Clay Clay Energy Fiji
IRENA - Renewable Energy Applications for Island Tourism: The Business Case for PV Systems - Fiji Presenter: Bruce Clay Clay Energy Fiji Page01 The Pacific Page02 Off-Grid Island RE Power 01/ PV/Diesel
CSP. Feranova Reflect Technology. klimaneutral natureoffice.com DE-296-558771 gedruckt
RENEWABLE SOURCES RENEWABLE SOURCES CSP Feranova Reflect Technology klimaneutral natureoffice.com DE-296-558771 gedruckt Gedruckt auf 100% Recyclingpapier Circlesilk Premium White 200/150 g/m 2 2012 Feranova
Remodelling of the heating systems of a sports centre based on life cycle assessment. Part II: Solar hybrid system.
European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ) International Conference on Renewable Energies and Power Quality (ICREPQ 12) Santiago de Compostela
ENERGY SAVINGS FROM SOLAR HEATED WATER IN BULGARIA
ENERGY SAVINGS FROM SOLAR HEATED WATER IN BULGARIA R. Todorova National Institute of Meteorology and Hydrology Blvd.Tzarigradsko shousee 66 Email: [email protected] Abstract At the present work
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING
PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING LI CHUNYING DOCTOR OF PHILOSOPHY CITY UNIVERSITY OF HONG KONG FEBRUARY 2012 CITY UNIVERSITY OF HONG KONG 香 港 城 市 大 學 Performance Evaluation of Water-flow
Solutions for a low carbon production in the food industry
Solutions for a low carbon production in the food industry Brunner Christoph Muster-Slawitsch Bettina, Weiss Werner AEE - Institute for Sustainable Technologies (AEE INTEC) A-8200 Gleisdorf, Feldgasse
Range Tribune HE Solar Unvented Direct and Indirect Cylinders
Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range
Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: 86-531-8235 5576 Fax: 86-531-82357911 Http://www.vicot.com.
Vicot Solar Air Conditioning V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: 86-531-8235 5576 Fax: 86-531-82357911 Http://www.vicot.com.cn Cooling, heating, and domestic hot water. Return on investment
ENERGY BALANCE OF LOW ENERGY HOUSE WITH GHPS IN HOKKAIDO
ENERGY BALANCE OF LOW ENERGY HOUSE WITH GHPS IN HOKKAIDO Yasuhiro Hamada, Kiyoshi Ochifuji, Makoto Nakamura and Katsunori Nagano Division of Urban and Environmental Engineering Graduate School of Engineering,
Future Megacities in Balance Low Carbon Cities in Making: Masdar City Tobias Fiedler, TRANSSOLAR Energietechnik, Stuttgart
Future Megacities in Balance Low Carbon Cities in Making: Masdar City Tobias Fiedler, TRANSSOLAR Energietechnik, Stuttgart Zeche Zollverein, Essen 11 th of October 2010 TRANSSOLAR Climate Engineering sustainable
Proposal prepared for Happy Solar Owner
Happy Solar Owner 1234 Sunny Lane Portland, OR 97201 Mailing Address: Happy Solar Owner 1234 Sunny Lane Portland, OR 97201 RE: SolarWorld Sunkits System Proposal: CASSK-## Presented by: SolarWorld Authorized
SOLAR THERMAL SYSTEMS FOR DOMESTIC HOT WATER AND SPACE HEATING UELI FREI, PETER VOGELSANGER
SOLAR THERMAL SYSTEMS FOR DOMESTIC HOT WATER AND SPACE HEATING UELI FREI, PETER VOGELSANGER SPF Institut für Solartechnik Prüfung Forschung HSR Hochschule Rapperswil, PF 1475, CH-8640 Rapperswil Tel.:
Interest Rates. Countrywide Building Society. Savings Growth Data Sheet. Gross (% per annum)
Interest Rates (% per annum) Countrywide Building Society This is the rate of simple interest earned in a year (before deducting tax). Dividing by 12 gives the monthly rate of interest. Annual Equivalent
Integrated Thermal Energy Systems
TVE 16 045 juni Examensarbete 15 hp Juni 2016 Integrated Thermal Energy Systems A Case Study of Nya Studenternas IP and Uppsala University Hospital Mika Bäckelie Thomas Lindén Freja Nielsen Emma Pålsson
For millennia people have known about the sun s energy potential, using it in passive
Introduction For millennia people have known about the sun s energy potential, using it in passive applications like heating homes and drying laundry. In the last century and a half, however, it was discovered
Making heating systems efficient and cost-effective: boilers, heating controls & more
Making heating systems efficient and cost-effective: boilers, heating controls & more WHAT WE USE ENERGY FOR IN OUR HOMES DECC Energy Consumption in the UK, 2010: Table 3.3 Heating building & hot water
Mailing Address 4650 Adohr Ln. Camarillo, CA 93012. 25 Year Financial Analysis. $1,051 / mo (avg) Cost Breakdown. System Description
Summary Customer Dan Glaser - CASSK-13-00932 SolarWorld USA Site Address 4650 Adohr Ln. Camarillo, CA 93012 Mailing Address 4650 Adohr Ln. Camarillo, CA 93012 Company Contact We turn sunlight into power
Applying ICT and IoT to Multifamily Buildings. U.S. Department of Energy Buildings Interoperability Vision Meeting March 12, 2015 Jeff Hendler, ETS
Applying ICT and IoT to Multifamily Buildings U.S. Department of Energy Buildings Interoperability Vision Meeting March 12, 2015 Jeff Hendler, ETS ETS is an Energy Technology, Behavior Management, and
Auburn University s Solar Photovoltaic Array Tilt Angle and Tracking Performance Experiment
Auburn University s Solar Photovoltaic Array Tilt Angle and Tracking Performance Experiment Julie A. Rodiek 1, Steve R. Best 2, and Casey Still 3 Space Research Institute, Auburn University, AL, 36849,
Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates
Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates Arthur Rosenfeld, California Energy Commission Gregory Rosenquist, Lawrence Berkeley National Laboratory C. Keith Rice,
Design issues For Net Zero Energy Buildings. Laura Aelenei 26 de Junho de 2012
Design issues For Net Zero Energy Buildings Laura Aelenei 26 de Junho de Summary 1.Context Building regulation/policy requirements Scientific advancements 2. Design issues for NZEB General ideas Solar
OPTIMAL POLYGEN COOLING CONCEPT FOR ST. OLAVS HOSPITAL IN TRONDHEIM, NORWAY
1st European Conference on Polygeneration OPTIMAL POLYGEN COOLING CONCEPT FOR ST. OLAVS HOSPITAL IN TRONDHEIM, NORWAY G. Eggen 1, A. Utne 2 1) COWI A/S, PB 2564 Sentrum, NO-7414 Trondheim, Norway, e-mail:
Professional Simulation Programmes. Design and Optimization
Professional Simulation Programmes for the Design and Optimization of Solar Thermal and Photovoltaic Systems Gerhard Valentin 1 Agenda Introduction Our Mission PV*SOL Simulation of Photovoltaic Systems
Geothermal Heat Pump Systems: From Basics to Hybrids
Geothermal Heat Pump Systems: From Basics to Hybrids January 17, 2013 Scott Hackel Energy Center of Wisconsin www.ecw.org/hybrid Today s discussion The basics of geothermal The hybrid approach, our recent
Commercial Gas Heat Pump - VRF
SANYO GHP Introduction Commercial Gas Heat Pump - VRF 01.12.2011 Agenda 1. SANYO GHP History 2. SANYO GHP Range 3. GHP Market Position 4. 2-WAY 5. GHP Power 6. 3-WAY 7. EER/COP 8. Water Heat Exchanger
Molten Salt for Parabolic Trough Applications: System Simulation and Scale Effects
Available online at www.sciencedirect.com Energy Procedia 00 (2013) 000 000 www.elsevier.com/locate/procedia SolarPACES 2013 Molten Salt for Parabolic Trough Applications: System Simulation and Scale Effects
Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.
EHYHBH05AA EHYHBH08AA EHYHBX08AA English Table of contents Table of contents 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout... 2 3 Operation 3 3.1 Overview: Operation...
Shade Analysis & Inspection Protocol www.energycenter.org
Pacific Power California Solar Incentive Program Shade Analysis & Inspection Protocol Agenda Conducting a Shade Analysis Process Tools Methodology Determining Tilt and Azimuth Field Inspection Overview