Conversion of a USP Gas Chromatography Method to Convergence Chromatography: Analysis of Atropa Belladonna



Similar documents
Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Hydrophilic-Interaction Chromatography (HILIC) for LC-MS/MS Analysis of Monoamine Neurotransmitters using XBridge BEH Amide XP Columns

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Signal, Noise, and Detection Limits in Mass Spectrometry

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Salman Azimi, 1 Nayan S. Mistry, 2 and Michelle Wood 2. Drug Quality Control Laboratory, Supreme Council of Health, Doha, Qatar 2

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

How To Use An Acquity Qda Detector

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Pesticide Analysis by Mass Spectrometry

How To Test For Contamination In Large Volume Water

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Analytical Test Method Validation Report Template

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Tamsulosin Hydrochloride Capsules

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Robert Birdsall, Eoin Cosgrave, Henry Shion, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Appendix 5 Overview of requirements in English

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

ApplicationNOTE Introduction

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Oasis HLB Cartridges and 96-Well Plates

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

AMINO ACID ANALYSIS By High Performance Capillary Electrophoresis

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Drospirenone and Ethinyl Estradiol Tablets. Type of Posting. Revision Bulletin Posting Date. 31 July 2015 Official Date

AMD Analysis & Technology AG

Eleanor Riches Waters Corporation, Manchester, UK INTRODUCTION

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

23 The Thermal Conductivity Detector

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Determination of Caffeine in Beverages HPLC-1

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Guidance for Industry

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

Analyzing Small Molecules by EI and GC-MS. July 2014

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Screening and quantitative determination of drugs in diluted urine by UPLC-MS-MS

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

International Journal of Pharma and Bio Sciences V1(2)2010

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

METHOD OF ANALYSIS. N methyl 2-pyrrolidone

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Quantitation of Drugs in Dried Bloodstains. Thomas Meyer Anna Gomenyuk Nadiah Lester

High Sensitivity MS Determination of Carryover in a New Autosampler Design

Articaine & Epinephrine Injection according to USP method

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

MEDICINAL CHEMISTRY APPLICATIONS BOOK

Analytical Test Report

S olid Ph ase Extraction (SP E) Method:

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

RAPID MARKER IDENTIFICATION AND CHARACTERISATION OF ESSENTIAL OILS USING A CHEMOMETRIC APROACH

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Waters Core Chromatography Training (2 Days)

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Electrospray Ion Trap Mass Spectrometry. Introduction

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Transcription:

Conversion of a USP Gas Chromatography Method to Convergence Chromatography: Analysis of Atropa Belladonna Paula Hong and Pat McConville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S UPC 2, compatible with heat labile compounds, is used as an alternative to gas chromatography High throughput, robust analysis is completed in less than five minutes Linear dynamic range from 10 to 400 µg/ml UPC 2 method compatible with mass spectrometry for identification of unknown components INT RO DU C T ION The extract of Atropa belladonna, a perennial native to south and central Europe, North Africa, and East Asia has been used for centuries to treat a number of medical conditions, including ulcers and other gastrointestinal disorders, and pain. It is also used as an anti-muscarinic agent. The extract is primarily composed of the tropane alkaloids, scopolamine and hyoscyamine (atropine), which are not only effective medicinal agents but are also highly toxic. This dichotomy makes quantification of these alkaloids in extracts critical for safety. The current United States Pharmacopoeial Convention (USP) method for Atropa belladonna extract specifies a gas chromatography (GC) method, using a 1.2 x 4.0 mm glass column packed with 3% G3 on S1AB with helium as a carrier gas. The use of highly volatile diluent dichloromethane is required for sample preparation. While direct injection is typically performed for these analyses, the high temperature required for GC analyses can lead to dehydration and conversion of scopolamine and atropine to their apo-forms. 1 Often, these issues are resolved by derivatization. 2 This application demonstrates the conversion of the USP method to convergence chromatography. The use of supercritical carbon dioxide (CO 2 ) as a mobile phase, combined with modifiers and additives, allows for a robust quantitative alternate method to GC with improved sample stability and simplified sample preparation. WAT E R S SO LU T IONS ACQUITY UPC 2 System with PDA and SQD detection ACQUITY UPC 2 BEH 1.7 µm columns Empower 3 Software Atropine Figure 1. Structures of atropine and scopolamine. 3 Scopolamine K E Y W O R D S UPC 2, convergence chromatography, alkaloid, gas chromatography, USP method transfer 1

E X P E R IM E N TA L Sample description Standard solutions of scopolamine hydrobromide (CAS# 114-49-8), atropine free base (CAS# 51-55-8), and homatropine hydrobromide (CAS# 51-56-9) were prepared in 2-propanol. All stock solutions were prepared at 1 mg/ml. Stock solutions were sonicated to ensure dissolution. Calibration standards of scopolamine and atropine were prepared from the stock solutions at 5, 10, 50, 100, 200, and 400 µg/ml with the internal standard (homatropine) at 50 µg/ml. A commercially available Atropa belladonna extract was purchased. Both the extract and a matrix blank were analyzed. The extract was diluted 1:3 (4x) in 2-propanol. The internal standard (homatropine) was added at 50 µg/ml. The combined solution was filtered, prior to analysis, with a 1-µm glass filter. The matrix blank was spiked with 100 µg/ml of atropine, scopolamine, and internal standard at 50 µg/ml. Column temp.: 50 C Sample temp.: 15 C ABPR: 2000 psi (138 bar) Injection volume: 1 µl Flow rate: 2 ml/min Mobile phase A: CO 2 Mobile phase B: 0.2% ammonium hydroxide (28% to 30%) in 98:2 (v/v) methanol/water Gradient: 10% to 30% B in 4.5 min, 30% to 40% in 0.5 min, 40% to 5% in 0.5 min Weak needle wash: 2-propanol Strong needle wash, seal wash: Methanol Conditioning parameters: 1 ml/min, 100% mobile phase B UPC 2 conditions System: Detection: ACQUITY UPC 2 with PDA and SQD detection PDA at 220 nm, compensated MS conditions Mass Spectrometer: Splitter: ACQUITY SQD with PCM II and 515 Pump for makeup flow UPC 2 MS splitter 410 to 480 nm Ionization mode: ESI+ Vials: Sample filter: Column: Clear Maximum Recovery Vials, Screw Neck (p/n 186000327C) Acrodisc, syringe filter, glass filter (p/n WAT 200819) ACQUITY UPC 2 BEH 3.0 x 100 mm, 1.7 µm Acquisition range: 70 to 500 m/z Capillary voltage : 3 Cone voltage: 30 Desolvation gas: 500 Makeup flow: 0.4 ml/min methanol Data management: Empower 3 Software 2

R E SU LT S A N D D IS C U S S ION The analysis of Atropa belladonna extract by GC has been well documented. 2 The USP methodology requires the use of GC for quantification of scopolamine and atropine. The assay suitability requirements include the following: Peak area s ratio for atropine (A) to homatropine (H) within 2% relative standard deviation (RSD) for six to ten injections USP resolution of greater than 3.0 for homatropine and atropine USP tailing factor of less than 2.0 for atropine In order to demonstrate equivalence of the UPC 2 method, these criteria as well as robustness were evaluated. UltraPerformance Convergence Chromatography (UPC 2 ) is a separation technique that uses supercritical CO 2 as the primary mobile phase. For highly basic compounds, modifiers containing basic additives are required to minimize secondary interactions and improve peak shape. 4 For the analysis of atropine (basic) and scopolamine (neutral), initial screening was performed on a number of different stationary phases using methanol as a co-solvent or modifier. As expected, poor peak shape was observed for atropine. The addition of basic additives improved peak shape to satisfy the tailing factor requirement in the USP method. Ammonium hydroxide was selected as the additive of choice because of its compatibility with mass spectrometry. Water was used as a second additive to further improve peak shape and reproducibility. The resulting method, on an ethylenebridged hybrid (BEH) stationary phase, met all of the USP suitability requirements, shown in Table 1, as well as allowing for a high throughput method in less than 5 minutes. Prior to suitability testing the column was also conditioned for 2.5 hours or 200 column volumes of the modifier-additive. Parameter USP Criteria UPC 2 Analysis Relative standard deviation of six to ten injections for the ratio R A /R H <2.0 <1.6 Resolution, R, between αh and α A >3.0 >3.9 Tailing factor measured at 5% of the peak height of a A <2.0 <1.5 Linear dynamic range for scopolamine and atropine (orders of magnitude) Table 1. Comparison of USP suitability criteria and UPC 2 results for analysis of Atropa belladonna extract. 3x 40x 3

In order to meet the USP suitability requirements and evaluate reproducibility, eight replicate injections were performed for each calibration standard. Retention time reproducibility was within 0.05% RSD for each standard. Peak areas relative to the internal standard (H) were less than 1.6% for both scopolamine and atropine, meeting USP suitability requirements. The standard chromatograms also displayed a peak for bromide at approximately 2.8 minutes. 0.030 S 0.025 0.020 A AU 0.015 0.010 (IS) H 0.005 0.000 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Figure 2. Overlay of eight replicate UPC 2 separations of Atropa belladonna extract standards, scopolamine (S), and atropine (A) (200 µg/ml). Homatropine (H) internal standard (50 µg/ml). UV at 220 nm compensated wavelength. Based on the standard described in the USP method, the requirements for the linear dynamic range are equivalent to 32 to 120 µg/ml for scopolamine and 320 to 1200 µg/ml for atropine. Conversion to UPC 2 required a shift to lower levels for atropine due to mass overloading above 400 µg/ml; however, the overall linear dynamic range was exceeded for both components (40x versus 3x per component). Linearity was achieved from 10 to 400 µg/ml (0.01% to 0.4%) for both scopolamine and atropine, as shown in Figure 3 and Table 2. Overlay chromatograms of the complete set of calibration standards were evaluated, as shown in Figure 3. There was no significant distortion that compromised quantification of atropine or scopolamine over the tested range of concentrations. The detection levels are within the linearity specifications for the detector. These characteristics indicate that the qualitative properties of the assays are maintained over this concentration range. 4

0.060 0.050 A 0.040 AU 0.030 S 0.020 (IS) H 0.010 0.000 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 Figure 3. Overlay of linearity calibration standards from 10 to 400 µg/ml. Injection n=8 at each level. The resulting convergence chromatography method met all of the suitability requirements specified for the USP method. Peak area reproducibility was calculated relative to the internal standard (homatropine), where Ratio(A) = Area(A)/Area(H). The area ratio %RSD for scopolamine and atropine were within the suitability guidelines (<2%). The linear dynamic range met all specifications with R 2 > 0.999, deviation <10% for points at the limit of quantitation (LOQ) and <5% for all other points in the calibration curve. The USP signal-to-noise (S/N) ratio was >10 at 10 µg/ml which was the LOQ. The limit of detection (LOD), defined as USP S/N >3.0, was 5 µg/ml for atropine and <5 µg/ml for scopolamine. These results are summarized in Table 2. Scopolamine Atropine tr (at 0.001%) Mean (min) 1.50 4.11 Std Dev (min) 0.000991 0.00158 RSD (%) 0.0658 0.0385 Area (A X /A H ) at 0.001% Mean 0.208 0.214 Std Dev 0.00386 0.00335 RSD (%) 1.86 1.56 R 2 0.9995 0.9998 Equation Y= 19.5x + 0.0236 Y= 21.8x -0.000394 S/N LOQ at 0.001% 27.5 17.4 S/N LOD at 0.0005% 9.95 6.98 Table 2. Linearity data for scopolamine and atropine by UPC 2. 5

While the USP method outlines the procedure for extraction of Atropa belladonna leaves, because of limited availability commercial Atropa belladonna extract was substituted and analyzed using the newly developed UPC 2 method. For equivalency of the UPC 2 method compared to the USP GC method, dilution of the extract by a factor of 4 was required. The extract was diluted in 2-propanol to minimize peak distortion. The internal standard (homatropine) was added to extract, and filtration of the diluted sample was required to remove particulates that formed with the addition of the diluent. The diluted extract contained 49.25 µg/ml atropine or 197 µg/ml in the commercial preparation. Scopolamine was present at levels below the LOQ of both the UPC 2 and USP GC method. To ensure accurate quantification of the extract, a matrix blank was spiked with scopolamine and atropine. Recoveries of 105% and 110%, respectively, were observed. Scopolamine Atropine Average (n=8) N/D 0.493 Std Dev N/D 0.000886 %RSD N/D 1.79 Table 3. Quantification data measured in µg/ml of diluted commercial Atropa belladonna extract. Eight replicate injections were performed. Mass spectrometry (MS) was used for confirmation of the analytes of interest as well as identification of any unknown components in the extract. While the analysis of the Atropa belladonna extract by UV indicated very low amounts of quantifiable scopolamine, single ion recording (SIR) in MS revealed the presence of scopolamine in the extract at levels below the LOD of the UV method, as shown in Figure 4A. In addition, a peak at 2.8 min was present in the extract but not observed in the calibration standards. The mass spectrum indicated the peak (m/z 154.4) is consistent with the mass of scopine which is likely formed by the hydrolysis of scopolamine. 5 1.2x10 8 1.0x10 8 MS SIR Analyte m/z Scopolamine (S) 304.4 Homatropine (H) 276.3 (H) IS A Intensity 8.0x10 7 6.0x10 7 Atropine (A) 290.4 Scopine (S*) 154.4 4.0x10 7 2.0x10 7 S S* 0.0 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 0.12 0.10 S* AU 0.08 0.06 0.04 0.02 0.00 220 nmcompensated wavelength 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 (H ) IS A Figure 4. Comparison of UV (220 nm) and MS (SIR) chromatograms of commercial belladonna extract. 6

C O N C LUSIONS Convergence chromatography provides an alternative technique for the analysis of highly polar compounds that have been traditionally analyzed by GC, thereby simplifying sample preparation by eliminating the need for derivatization. 2 As described in this study, the use of supercritical CO 2 provides a reproducible, high throughput analysis for tropane alkaloids while meeting USP suitability guidelines. Furthermore, the robustness of the method illustrates the ability to develop reliable, quantitative methods using convergence chromatography. References 1. Solomon MJ, Crane FA, Chu BLW, Mika ES. Simultaneous quantitative gas chromatographic determination of atropine and scopolamine. Journal of Pharmaceutical Sciences. 1969; 58 (2): 264-266. 2. Aehle E, Drager B. Tropane alkaloid analysis by chromatographic and electrophoretic techniques: An update. Journal of Chromatography B. 2010; 878 (17-18): 1391-1406. 3. Gaulton A, Bellis LJ, Bento AP, Chambers J, Davies M, Hersey A, Light Y, McGlinchey S, Michalovich D, Al-Lazikani B, Overington JP. ChEMBL: A large-scale bioactivity database for drug discovery. Nucleic Acids Research. 2012; 40 (D1): D1100-D1107. 4. Grand-Guillaume Perrenoud A, Boccard J, Veuthey JL, Guillarme D. Analysis of basic compounds by supercritical fluid chromatography: Attempts to improve peak shape and maintain mass spectrometry compatibility. Journal of Chromatography A. 2012; 1262 (0): 205-213. 5. Meinwald J, Chapman OL. The Alkaline Hydrolysis of Scopolamine Methoxymethochloride: A New Route to Scopine. Journal of the American Chemical Society. 1957; 79 (3): 665-666. Waters, ACQUITY, and Empower are registered trademarks of Waters Corporation. ACQUITY UPC 2, UPC 2, UltraPerformance Convergence Chromatography, and The Science of What s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 2013 Waters Corporation. Produced in the U.S.A. January 2013 720004573EN AG-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com