ESIDENTIAL THEMSTATS LIMATEMASTE ETHEMAL HEATIN AND LIN MFT SYSTEMS ESIDENTIAL THEMSTAT PDUT UIDE THE LBAL LEADE
esidential Thermostats 3.30 in [83.8mm] Fan: turns continuous fan FF or N 0.8 in Depth [20.3mm] Mounting: 4.55 in [115.6mm] Mode: Selects system mode - FF, HEAT, L, or EMHEAT 1.587in (40.3mm) Fault Light UP 2.375in (60.3mm) Temperature increase Temperature decrease ATM21U01 Two Heat / ne ool Manual hangeover Non-Programmable Features (cont.): Setup feature allows either current room temp or the current setpoint to be displayed. ptional safety setpoints ensure that heating and cooling will occur even if thermostat is in ff mode. Backplate wiring for easy installation. Specifications: Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. Temperature Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. The default setpoint for heating is 70 F [21 ] and for cooling is 74 F [23 ]. Press the or keys to change the setting. To change between heat and cool settings, press the mode key until the setting to be changed appears. Display ange: Display Updates: ontrolled: updated every 12 seconds. Differential (autochangeover model): 3 F [1.5 ] minimum. utput atings: Maximum current for each output is 1 Amp. 2.625in (66.7mm) 3.275in (83.2mm) iring: onnection to XM ontrol ATM21U01 Thermostat XM Application: The ATM21U01 electronic thermostat provides two-stage heat, one-stage cool, non-programmable temperature control for 24V water-source heat pump systems. Features: Heat-ff-ool-Em Heat System selections. Fan-n-Auto selections. F or temperature display. Manual changeover operation. Light emitting diode (LED) for alarm status. Installer setup options allow for customized applications. Zero temperature droop performance. Temperature display adjustment feature provides display offset for custom applications. Setpoints are permanently held in memory (no batteries used) and retained during power outages. Extended fan operation feature can be used to operate fan for 90 seconds after Y turns off. ompressor Heating Stage 2 eversing Valve Fan 24Vac Hot 24Vac ommon Fault LED Y / L Y limatemaster esidential Thermostats - ev.: 02/13/06 3
limatemaster Fan: turns continuous fan FF or N 4.55 in [115.6mm] Fault Light Temperature: increase ATA22U01 Two Heat / Two ool or Two Heat / ne ool (hen used with auxiliary electric heat) Auto / Manual hangeover Non-Programmable 3.30 in [83.8mm] Temperature: decrease Features (cont.): Setup feature allows either current room temp or the current setpoint to be displayed. ptional safety setpoints ensure that heating and cooling will occur even if thermostat is in ff mode. Backplate wiring for easy installation. 0.8 in Depth [20.3mm] Mode: Selects system mode - FF, HEAT, L, EMHEAT, or AUT Specifications: Electrical ating: Input Power: 18 to 30 Vac, 50/60 Hz. Mounting: 1.587in (40.3mm) 2.375in (60.3mm) Temperature Settings: Setpoint ange: 50 F to 90 F [10 to 32 ]. The default setpoint for heating is 70 F [21 ] and for cooling is 74 F [23 ]. Press the or keys to change the setting. To change between heat and cool settings, press the mode key until the setting to be changed appears. UP Display ange: Display Updates: ontrolled: updated every 12 seconds. Differential (autochangeover model): 3 F [1.5 ] minimum. Application: The ATA22U01 electronic thermostat provides two-stage, nonprogrammable temperature control for 24V water-source heat pump systems. Features: 2.625in (66.7mm) 3.275in (83.2mm) Heat-ff-ool-Em Heat-Auto System selections. Fan-n-Auto selections. F or temperature display. onfi gurable automatic or manual changeover operation. Light emitting diode (LED) for alarm status. Installer setup options allow for customized applications. Zero temperature droop performance. Temperature display adjustment feature provides display offset for custom applications. Setpoints are permanently held in memory (no batteries used) and retained during power outages. Extended fan operation feature can be used to operate fan for 90 seconds after Y turns off. utput atings: Maximum current for each output is 1 Amp. iring: onnection to XM ontrol ATA22U01 Thermostat ompressor Heating Stage 2 eversing Valve Fan 24Vac Hot 24Vac ommon Fault LED Y / L Note 1 XM Y Note 1: ptional onnection for Heating Stage 2 operation, Thermostat "" option must be configured as " - ff".this configuration uses the compressor only for 1st stage heating and compressor plus auxilliary heat for 2nd stage operation. The thermostat is configured as a two stage heat / one stage cool thermostat for single speed units with PS fan and backup heat. For two-stage units with backup heat or units with EM fan and backup heat, a three stage heat / 2 stage cool thermostat is required. 4 limatemaster esidential Thermostats - ev.: 02/13/06
esidential Thermostats 6.25 in [158.8mm] ATA32U01 Three Heat / Two ool Auto / Manual hangeover Non-Programmable 4.25 in [108.0mm] 1.1 in Depth [27.9mm] Features (cont.): Menu-driven programming with fi ve navigation buttons (UP/ DN/LEFT/IHT/SELET) for ease of use Fault indication with red backlight display onfi gurable service interval messages and servicing contractor contact information Keypad lockout Back-plate wiring connections for easy installation Exclusive fault identifi cation (hen used with XM or DXM) displays fault from XM/DXM board (e.g. condensate overfl ow) and suggests possible causes ompatible with AST008 sensor for use as remote and/or outdoor sensor Dual fuel capable Mounting: UP 0.72" [18.3mm] Specifications: Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz perating onditions: 32ºF to 104ºF [0º to 40º] 10% to 95% non-condensing 2.90" [73.7mm] 6.25" [158.8mm] Temperature Settings: Set point range: 40ºF to 90ºF [4º to 32º], +/- 2ºF [1º] utput atings: Maximum current for each output is 1.0 Amp (2.0 max. output total). 0.62" [15.7mm] iring: onnection to EM ontrol Application: The ATA32U01 Thermostat provides 3 stages heating, 2 stages of cooling, and non-programmable temperature control of 24V water-source heat pump equipment. Features: Heat-ff-ool-Em Heat-Auto System Selections ºF or º temperature display Individual heat and cool set points Zero temperature droop performance Automatic or manual changeover Set points are permanently held in memory (no batteries used) and retained during power outages oom temperature offset adjustment Large backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds ATA32U01 Thermostat ompressor ompressor Stage 2 Auxiliary Heat eversing Valve Fan 24Vac Hot 24Vac ommon Fault LED L EM limatemaster esidential Thermostats - ev.: 02/13/06 5
limatemaster 6.25 in [158.8mm] ATP32U01 Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) Features (cont.): 4.25 in [108.0mm] 1.1 in Depth [27.9mm] Mounting: UP 0.72" [18.3mm] oom temperature offset adjustment Progressive ecovery anticipates the time required to bring the space temperature to the next programmed event, and brings on the heat pump accordingly Large backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds Menu-driven programming with fi ve navigation buttons (UP/ DN/LEFT/IHT/SELET) for ease of use Fault indication with red backlight display onfi gurable service interval messages and servicing contractor contact information Keypad lockout Back-plate wiring connections for easy installation Exclusive fault identifi cation (hen used with XM or DXM) displays fault from XM/DXM board (e.g. condensate overfl ow) and suggests possible causes ompatible with AST008 sensor for use as remote and/or outdoor sensor Dual fuel capable Specifications: Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz 2.90" [73.7mm] 6.25" [158.8mm] perating onditions: 32ºF to 104ºF [0º to 40º] 10% to 95% non-condensing Temperature Settings: Set point range: 40ºF to 90ºF [4º to 32º], +/- 2ºF [1º] 0.62" [15.7mm] utput atings: Maximum current for each output is 1.0 Amp (2.0 max. output total). Application: The ATP32U01 Thermostat provides 3 stages heating, 2 stages of cooling, and programmable temperature control of 24V water-source heat pump equipment. iring: onnection to EM ontrol ATP32U01 Thermostat EM Features: 7-day programming. Four periods per day. ºF or º temperature display 12 or 24 hour clock Individual heat and cool set points Zero temperature droop performance Automatic (program mode) or manual (HLD) operation onvenient overrides allow temporary set point changes Set points are permanently held in memory (no batteries used) and retained during power outages ompressor ompressor Stage 2 Auxiliary Heat eversing Valve Fan 24Vac Hot 24Vac ommon Fault LED L 6 limatemaster esidential Thermostats - ev.: 02/13/06
esidential Thermostats 6.25 in [158.8mm] ATP32U02 Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) ith Humidity ontrol 4.25 in [108.0mm] 1.1 in Depth [27.9mm] Mounting: UP 0.72" [18.3mm] 2.90" [73.7mm] 6.25" [158.8mm] Features (cont.): Four periods per day ºF or º temperature display 12 or 24 hour clock Individual heat and cool set points Zero temperature droop performance Automatic (program mode) or manual (HLD) operation onvenient overrides allow temporary set point changes Set points are permanently held in memory (no batteries used) and retained during power outages oom temperature offset adjustment Progressive ecovery anticipates the time required to bring the space temperature to the next programmed event, and brings on the heat pump accordingly Large backlit dot matrix display is activated whenever a key is pressed and remains on for 25 seconds Menu-driven programming with fi ve navigation buttons (UP/ DN/LEFT/IHT/SELET) for ease of use Fault indication with red backlight display onfi gurable service interval messages and servicing contractor contact information Keypad lockout Back-plate wiring connections for easy installation Exclusive fault identifi cation (hen used with XM or DXM) displays fault from XM/DXM board (e.g. condensate overfl ow) and suggests possible causes ompatible with AST008 sensor for use as remote and/or outdoor sensor Dual fuel capable 0.62" [15.7mm] Specifications: Electrical ating: Input Power: 18 to 30 VA, 50/60 Hz Application: The ATP32U02 Thermostat provides 3 stages heating, 2 stages of cooling, and programmable temperature/humidity control of 24V water-source heat pump equipment. Features: 7-day programming. Programmable or non-programmable operation Dehumidifi cation output is designed to work with limadry Modulating eheat option or with EM fan motor dehumidifi cation mode Integrated control of both temperature and relative humidity Integrated control eliminates separate thermostat and dehumidistat/humidistat Thermostat can be programmed to use humidifi cation output to control a humidifi er perating onditions: 32ºF to 104ºF [0º to 40º] 10% to 95% non-condensing Temperature Settings: Set point range: 40ºF to 90ºF [4º to 32º], +/- 2ºF [1º] Dehumidifi cation set point range: 15% to 95% H Humidifi cation set point range: 10% to 45% H utput atings: Maximum current for each output is 1.0 Amp (2.0 max. output total). limatemaster esidential Thermostats - ev.: 02/13/06 7
limatemaster iring: Units with EM Fan onnection to EM ontrol ATP32U02 Thermostat EM ATP32U02 Three Heat / Two ool Auto / Manual hangeover Programmable (7 Day) ith Humidity ontrol ompressor ompressor Stage 2 Auxiliary Heat Units with limadry Dehumidification eversing Valve DH DH onnection to DXM ontrol Fan 24Vac Hot 24Vac ommon Fault LED L ATP32U02 Thermostat ompressor ompressor Stage 2 DXM Units with XM or DXM board and EM fan motor, utilizing EM dehumidification mode (w/o limadry option) Notes: 1) EM dehumidification mode slows down fan speed in the cooling mode when dehumidification output from thermostat is active. Normal heating and cooling fan speeds are not affected. 2) EM board DIP switch S9 must be in dehumid. mode. Auxiliary Heat Dehumidification eversing Valve Fan 24Vac Hot 24Vac ommon Fault LED DH L 1 H /2 Units with EM Fan and limadry hole House Dehumidification ption Unit with limadry ption and DXM board (PS fan motor) onnection to EM & DXM ontrol ATP32U02 Thermostat EM DXM ompressor ompressor Stage 2 Auxiliary Heat 1 Dehumidification DH H eversing Valve /2 Fan 24Vac Hot 24Vac ommon Fault LED L Single or two-stage unit with limadry ption and DXM board (EM fan motor) 8 limatemaster esidential Thermostats - ev.: 02/13/06
esidential Thermostats limatemaster esidential Thermostats - ev.: 02/13/06 9
limatemaster 10 limatemaster esidential Thermostats - ev.: 02/13/06
evision Log Date Page Description 02/13/06 All First Published IS 9001:2000 ertified Quality: First & Always 7300 S.. 44th Street klahoma ity, K 73179 Phone: 405-745-6000 Fax: 405-745-6058 www.climatemaster.com limatemaster works continually to improve its products. As a result, the design and specifi cations of each product at the time for order may be changed without notice and may not be as described herein. Please contact limatemaster s ustomer Service Department at 1-405-745-6000 for specifi c information on the current design and spec i fi ca tions. Statements and other in for ma tion contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely limatemaster s opinion or com men da tion of its products. The management system governing the manufacture of limatemaster s products is IS 9001:2000 certifi ed. P806 limatemaster, Inc. 2006 ev.: 02/13/06D