RFID systems. Communications modules ASM 450 4/139. Overview



Similar documents
CP Page 1342 Mar 2008 Siemens ITS

The CP provides access to different communication services of the PROFIBUS bus system:

The CP FO provides access to different communication services of the PROFIBUS bus system:

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

CPUs - CPU PN/DP

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

Fieldbus slave modules with I/Os, DIO

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

Rack mounted telephone- and leased line modem for industrial applications

Data sheet SLIO CPU 015 (015-CEFPR00)

Telephone- and leased line modem for industrial applications TD-36

PCS0100en Persy Control Services B.V. Netherlands

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Modular I/O System Analog and Digital Interface Modules

6ES BE01-0AB0 6ES BE01-0AB0

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

MI4 - Operator Panel : Engineering

TEXT DISPLAY TD17 LC DISPLAY, BACK-LIT LED, 4X20/8X40 LINES X CHARACTERS F0R SIMATIC S5,505,S7,M7 NATIVE DRIVERS, PROFIBUS-DP12

Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

UCC 1 USB-CAN CONVERTER

Combi switchbox with integrated 3/2 way pilot valve

CB15/CB155. PROFIBUS Module

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

Manual Serial PCI Cards

SIMATIC NET. S7-CPs for PROFIBUS. CP Basic. Manual Part B3

CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date Rev. 0

TX OPEN RS232/485 module

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Barcode Reader Series BCL 31, BCL 32, BCL 34

applicomio Profibus-DP

Identification System. FC 44 Function for ASM 450 With Supplements for FB 240. Contents. General Features Hardware Description of ASM 450

SIMATIC Flat Panel Monitors

3 3RG78 45 program overview

SIMATIC Expert Communication Connecting S7-400H to PC Station (WinCC)

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

Siemens S7 PLC and FC 300 Profibus

User manual Compact Web PLC WP240 series IEC-line

Controllers. The integrated standard software guarantees highest quality standards! Simple and safe operation. Specific and clear indication

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

User Manual Revision English

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

L5354 ControlNet Communications Interface

S7 for Windows S7-300/400

NC-12 Modbus Application

SIMATIC VS720A and VS720-S series Intelligent cameras with PROFINET

DC Electronic Loads 8500 series

OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

SOFTLINK 300. CPU Specifications. Reference Manual

This guide describes the details that are necessary for making a HMI (PC RT or panel) for an S5 PLC.

SIMATIC PDM software. Siemens FI /1

Extract from the online catalog

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B en

is then retained absolutely without interruption.

SIMATIC. S7-300 Programmable Controller Installation and Hardware. Preface, Contents. Product Overview 1. Mechanical Configuration 2

40.3. Control Relays and Timers

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

CPU PN/DP. Function

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

PROFIBUS. 4/2 System interfacing for PG/PC 4/2 Overview 4/5 CP /11 CP /17 CP /23 CP 5711

HIPERDRIVE HRA71 and HIPER- DRIVE -HUB: Integrated positioning system with absolute distance measurement for format adjustment

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system


New XUY roller sensors

HARTING mcon 1000 Introduction and features

Operator Control and Monitoring Devices

1 Serial RS232 to Ethernet Adapter Installation Guide

TX2123 RS485 TO ETHERNET ADAPTOR

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AXIS 262+ Network Video Recorder

DMX2PWM 9 Channel Dimmer Setup Manual

Human Machine Interface

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

User Manual Revision English

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ZC-24DO CANopen I/O Module: 24 Digital Outputs

SIMATIC NET. S7-CPs for PROFIBUS Configuring and Commissioning

Communication Unit 560CMU05 Data sheet

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial

Transcription:

Overview The low-cost communications module ASM 50 is an autonomous PROFIBUS DP slave for the operation of MOBY components via the PROFIBUS DP: SIMATIC S7 (including FB/FC software) SINUMERIK SICOMP IMC, PC, PLC Thanks to their high degree of protection and ruggedness, they are particularly suitable for machine-level use. Design PROFIBUS-DP master module, e.g. S7-00 CPU AT-comp. PC RFID systems ASM 50 Function The PROFIBUS DP procedure according to EN 50170 Vol. 2 PROFIBUS for the communication between ASM and SIMATIC S5/S7 (or any PROFIBUS master) and the MOBY-specific procedures for communication between ASM and SLG are implemented on the ASMs. The data in the is accessed as follows: Direct addressing via absolute addresses On the PROFIBUS DP, the ASM occupies a node address on the bus that is set on the basic module. The ASM is integrated into the hardware configuration by means of a device master (GSD) file. Then the ASM can be configured by means of the software tool HW_Config of the SIMATIC Manager or another PROFIBUS tool. Error messages and operating states ( in the field, transmission, etc.) are indicated additionally by means of LEDs and simplify commissioning and service. For the connection to any PROFIBUS DP master, the software interface is disclosed in the documentation. The IP67 connectors ( 6ES719-1AA01-0XA0) are to be ordered separately! ASM 50 (for MOBY E/I) The ASM 50 has two SLG interfaces. When using two SLG interfaces, the module operates in multiplex mode so that the can only be read reliably when it is not moving. The data in the is accessed direct by means of absolute addresses. Using the software functions FC for the SIMATIC S7, the ASM operates in cyclic mode, i.e. the data throughput depends among other things on the size of the address window (max. 208 bytes), number of slaves, etc. PROFIBUS-cable to further PROFIBUSstations * Standard cable length 2 V for SLGs 2nd SLG (not for Filehandler) 1st SLG 2 m * G_KT01_EN_00052a Configuration The ASM communications modules are mounted on the ET 200X standard module. The relevant configuration and mounting instructions should be referred to in the ET 200X manual. Expansion modules from the ET 200X spectrum cannot be used. /139

RFID systems ASM 50 Technical specifications Communication modules ASM 50 Serial interface to user PROFIBUS DP Procedure conforms to: EN 50170 Vol. 2 PROFIBUS Connection to PROFIBUS PG 11 gland (3 x 6ES719-1AA01-0XA0, not included in scope of delivery) Data transmission rate 9.6 Kbaud to 12 Mbaud (automatic detection) Max. block length 208 byte Serial interface to SLG Connector Max. cable length 500 m, SLG-dependent, (standard length 2 m) Connectable SLGs SLG 7x or SLG x in multiplex mode Data transmission rate 19.2 Kbaud to 57.6 Kbaud (depending on the MOBY family) Software function Programming Depending on the PROFIBUS DP Master Function blocks SIMATIC S7 FC addressing Direct via addresses Commands Initialize, read data, write data, etc. Digital inputs/outputs 2/2 Galvanic isolation Yes Power supply Permissible range 20 30 V DC (rated value 2 V DC) Current consumption Max. 180 ma; typ. 130 ma (without SLG) Ambient temperature During operation 0 C +55 C During transportation and storage -0 C +70 C Degree of protection IP67 Dimensions (W x H x D) in mm 13 x 110 x 55 (without bus connector) Weight, approx. 0.5 kg Selection and Ordering data ASM 50 communication module Max. 2 SLGs can be connected in multiplex mode, without connectors Accessories Connector For ASM 50 for the PROFIBUS DP interface and 2 V supply, 3 units per ASM 50 are necessary Integrated plug connector for ASM 50; T functionality; spare part MOBY M12 dual-pin connector for ASM 50 For mounting individual ASM SLG, without cable MOBY E, I, U connecting cable Preassembled, between ASM 50 and SLG, angled connector, in the following lengths: 2 m (preferred length) 6GT2 002-0EB00 6ES719-1AA01-0XA0 6ES7 19-1FC00-0XA0 6GT2 090-0BC00 6GT2 091-1CH20 5 m A 6GT2 091-1CH50 10 m A 6GT2 091-1CN10 20 m A 6GT2 091-1CN20 50 m 6GT2 091-1CN50 Preassembled, between ASM 50 and SLG, angled connector 2 m long CD "RFID Systems Software & Documentation" FB/FC for SIMATIC, 396R driver for DOS/Windows 95/NT/2000/XP, C-libraries, PC presentation program, RFID documentation A 6GT2 091-2CH20 6GT2 080-2AA10 A: Subject to export regulations AL = N and ECCN = EAR99H /10

Overview The ASM 70 and 75 are low-cost modules for connecting the MOBY D, E, I, U and RF300 identification systems to the S7-300 and ET 200M. Application The ASM 70 and ASM 75 communications modules integrate the MOBY identification systems into the following systems: SIMATIC S7-300 S7-00, PC (CP512 (A2)) via ET 200M SINUMERIK 80D/810D A maximum of two SLGs can be connected and operated in parallel mode (ASM 70 only in multiplex mode). RFID systems ASM 70/75 Function As many as eight ASM communication modules can be plugged into one SIMATIC S7-300 rack and operated. In a configuration with several racks (max. ), the ASMs can be plugged into and operated on any rack. This means that as many as 32 ASMs can be operated in the maximum configuration of a SIMATIC S7-300. The electrical isolation between SLG and SIMATIC S7-300 bus ensures a noise-resistant setup. Error messages and operating states ( in field, command active etc.) are indicated using LEDs. Communication between the ASM 75 and S7-CPU takes place by means of acyclic message frames of the P-bus, so that the useful data (max. 238 byte) is transmitted very quickly and effectively. The ASM 75 is fully integrated into the diagnostics of the SIMATIC Manager by means of an Object Manager (OM). Depending on the PROFIBUS master, as many as 126 ET 200M modules can be operated on one PROFIBUS line. ASM 70 (for MOBY I/E) The data in the is accessed direct by means of physical addresses using the ASM 70. Communication with the ASM takes place in the process image in blocks of 12 byte and is slower than with the ASM 75. Via ET 200M, it can be operated on any non-siemens PROFIBUS master. ASM 75 (for MOBY I/E/U/D/RF300) The data in the is accessed direct by means of physical addresses using the ASM 75. The data is transferred between FC/FB5, FC55 and ASM at great speed and without placing a great load on the CPU. In the MOBY I/U mode, the ASM can also be operated with the FC56 (file handler). Design Dimensions ASM 70 ASM 75 125 Shield terminal (6ES7 390-5BA00-0AA0) Shield support element (6ES7 390-5AA00-0AA0) for 2 modules 0 116,9 6GT2 091-0E... SLG SLG G_KT01_EN_00053 FS10_90112 Configuration Communication module ASM 75 Technical specifications and Selection and Ordering data: See next page. /19

ASM 70/75 Technical specifications Communication modules ASM 70 ASM 75 ASM 75 (with MOBY I/U file handler) Serial interface to SLG RS22 SLG connection point Max. 2 pieces via screw terminals in front connector Interface/cable length, RS22/1000 m, depending on SLG and cable type max. connectable length Connectable SLGs MOBY I/E (multiplex mode) MOBY I/E/U/D/RF300 MOBY I/U Interface for 2 V DC Via screw terminals in front connector Function blocks SIMATIC S7 FC7 FC/FB5, FC55 (multitag) FC56 addressing Direct access via addresses Access via DOS-like file system Commands Initialize, read data from, write data to, etc. Dialog function yes (MOBY I) no Power supply Nominal value 2 V DC Permitted range 20 to 30 V DC Electrical isolation between S7-300 and MOBY Yes Current consumption from S7 bus terminal, 100 ma max. Power loss, typically 1 W Ambient temperature Operation Horizontal configuration of SIMATIC 0... +60 C Vertical configuration of SIMATIC 0... +0 C Transport and storage -0... +70 C Dimensions (W x H x D) in mm 0 x 125 x 120 Weight, approx. 0.2 kg Format, read file, write file, etc. Selection and Ordering data MOBY communication module ASM 70 For SIMATIC S7-300 and ET 200M MOBY communication module ASM 75 For SIMATIC S7-300 and ET 200M, parameterizable Accessories Front connector (1 x per ASM) MOBY E, I, U connecting cable Preassembled, between ASM 70/75 and write/read device, angled connector, in the following lengths: 6GT2 002-0FA10 6GT2 002-0GA10 6ES7 392-1AJ00-0AA0 2 m 6GT2 091-0EH20 5 m A 6GT2 091-0EH50 10 m A 6GT2 091-0EN10 20 m A 6GT2 091-0EN20 50 m A 6GT2 091-0EN50 Preassembled, between ASM 70/75 and write/read device, straight connector, in the following lengths: A: Subject to export regulations AL = N and ECCN = EAR99H 2 m A 6GT2 091-2EH20 5 m A 6GT2 091-2EH50 10 m 6GT2 091-2EN10 50 m 6GT2 091-2EN50 MOBY D connecting cable Pre-assembled, between the ASM 75 and SLG D1xS, 9-pin Sub-D connector in the following lengths: 5 m A 6GT2 91-0EH50 20 m A 6GT2 91-0EN20 50 m 6GT2 91-0EN50 SIMATIC RF300 connecting cable preassembled, between ASM 75 and RF3xxR, IP65, straight connector, in the following lengths 1) : 2 m A 6GT2 891-0EH20 5 m A 6GT2 891-0EH50 CD: "RFID Systems Software & 6GT2 080-2AA10 Documentation" FB/FC for SIMATIC, 396R driver for DOS/Windows 95/NT/2000/XP, C-libraries, PC presentation program, RFID documentation 1) The connecting cables can be extended using the RF300 connecting cable for the ASM 56. These connecting cables are supplied in the lengths 2 m, 5 m, 10 m, 20 m and 50 m (6GT2 891-0Fxxx) /150

ASM 2, ASM 75/72 Overview Up to write/read devices or antennas can be connected in parallel to the low-cost connection modules. The user can select between two interfaces: PROFIBUS DP-V1 (ASM 75) RS232/RS22; serial interface to PC/PLC (ASM 2, ASM 72) Design Mounting For easy mounting on a standard rail, an optional adapter is available. PROFIBUS: or RS232/RS22 2 V= 230 V ~ Function Up to four write/read devices or antennas from the corresponding MOBY system can be connected to the rugged housing. Data in the is accessed directly over the physical addresses. The extended MOBY E functions (multitag, access rights, password, etc.) are not supported. Error messages and operating states ( in the field, transmission, etc.) are indicated additionally by means of LEDs and simplify commissioning and service. PROFIBUS DP-V1 interface (ASM 75) Communication to the application uses the acyclic protocol service of PROFIBUS DP-V1. The station address on PROFIBUS is set directly on the ASM by means of a DIP switch. The functions FC5 or FC55 (multitag) are available to SIMATIC S7 users for easy integration in the application. The ASM is integrated into the hardware configuration via a GSD file. The ASM can then be configured via the SW tool HW_Config of SIMATIC Manager or another PROFIBUS tool. For connection to any PROFIBUS DP-V1 master, the programming interface is described in the FC5 documentation. RS232/RS22 interface (ASM 2, ASM 72) A WINDOWS 98/NT/2000 C library (MOBY API, DLL functions) incl. 396R driver with basic functions (open/close channel, read data from data memory, etc.) is available to the PC user for his application. MOBY E Up to four SLA 7x can be connected in parallel to the ASM 75/72 which, however, operate internally in multiplex mode. If more than one SLA 7x is connected, the MOBY E data memory can only be reliably read or written in the stationary state. MOBY I/E Up to four SLG x or SLG 7x can be connected in parallel to the ASM 2. MOBY data memories can be read or written simultaneously on all SLGs. SLG SLG SLG SLG G_KT01_EN_00055 Configuration /151

ASM 2, ASM 75/72 Technical specifications Communication module ASM 75 ASM 2, ASM 72 Serial interface to user PROFIBUS DP-V1, 9-pin Sub-D connector ( 6ES7 972-0BA 12-0AX0) RS232/RS22 9-pin Sub-D connector Cable length, max See PROFIBUS 30 m for RS232, 500 m for RS22 Procedure/protocol EN 50170 Vol. 2 PROFIBUS 396 R Data transmission rate 9600 Kbit/s up to 12 Kbit/s (automatic detection) 38. bit/s Block length, max words cyclic/ 238 byte acyclic 238 byte Serial interface to SLA/SLG x 9-pin Sub-D socket Cable length, max 55 m to SLA; 1000 m to SLG Connectable SLG/SLA MOBY I/E: max. x SLG x or SLG 7x (parallel mode) MOBY E: max. x SLA 7x (multiplex mode) Note: Mixed mode is not possible Software function Programming Depending on the PROFIBUS DP-V1 master Depending on the PC/PLC Available software (CD "RFID Systems FC5 for SIMATIC S7-300/00 C library MOBY API for PC with Windows 89/NT Software & Documentation ) addressing Access directly via addresses Commands Initialize, read data from, write to, etc. Power supply Rated value 2 V DC (separate connector) Permissible range 20 30 V DC Current consumption 250 ma Starting current, max. 1.1 A (without SLA) Mounting x M5 screws Degree of protection IP0 (higher degree of protection on request) MTBF (at 0 C) 100,000 hours Housing Dimensions (W x H x D) in mm 205 x 130 x 60 (without connector) Material Aluminum Color Anthracite Ambient temperature Operation -25 +55 C (condensation not permitted) For transport and storage -0 +85 C (condensation not permitted) Weight, approx. 1.3 kg Selection and Ordering data ASM 2 communication module With serial interface RS232/RS22, max. SLG x or SLG 7x can be connected ASM 72 communication module 6GT2 002-2CE00 A 6GT2 302-2CE00 With serial interface RS 232/RS22, max. SLA 7x can be connected 75 communication module 6GT2 302-2EE00 With PROFIBUS DP-V1 interface, max. SLG 7x can be connected Accessories CD: "RFID Systems Software & Documentation" FB/FC for SIMATIC, 396R driver for DOS/Windows 95/NT/2000/XP, C-libraries, PC presentation program, RFID documentation 6GT2 080-2AA10 A: Subject to export regulations AL = N and ECCN = EAR99H /152

Software Software Overview Benefits Management and operation of readers (write/read devices) Collection, visualization and preprocessing of tag data Routing of tag data to higher-level enterprise systems Application Both RF-MANAGER and the RF600 Data Manager support readers (write/read devices) of the RF660R type and can be used for applications with this reader. The main applications of the RF660R range from the recognition of goods in loading bays, at goods receipt and goods dispatch through goods flow control on conveyor belts as far as implementation in warehouses or distribution centers and in fill level control of high-bay warehouses. Industrial use in factories, e.g. in paintshops or on assembly lines in the automotive industry, is also possible. SIMATIC RF-MANAGER SIMATIC RF-MANAGER is software that is used for quick and easy creation and commissioning of RFID applications both for preprocessing and routing the delivered tag data to a higherlevel enterprise system (data & device management). In the current version, RF-MANAGER 2007, readers (write/read devices) of the RF660R type are supported exclusively. Depending on the scope of the RFID application, different software packages are available that differ in accordance with the number of supported readers (up to 50). /153