Mason County Building Department



Similar documents
Residential Deck Safety, Construction, and Repair

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Residential Decks. Planning and Development Services Department

Uncovered Decks & Porches

Typical Deck Details


COMMONLY USED RESIDENTIAL BUILDING CODES

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

POST AND FRAME STRUCTURES (Pole Barns)

PRESCRIPTIVE RESIDENTIAL DECK CONSTRUCTION GUIDE. decking guard. rim joist joists

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

BUILDING PERMIT SPECIFICATIONS

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

Number of Sides Required to Have a Handrail

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

RESIDENTIAL WOOD DECKS

STANDARD OPEN PATIO COVER

Mobile Home Pre-Inspection Checklist

Building Department John Fiedler Construction Official Ext SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev

Featuring TJ Rim Board and TimberStrand LSL

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

6 RETROFITTING POST & PIER HOUSES

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Chapter 3 Pre-Installation, Foundations and Piers

Timber Decks. Technical Note. March 2007

TYPICAL PATIO COVERS 111

Patio Covers / Carports

CITY OF TORONTO. BY-LAW No

Simplified Steel Stair Design for Commercial and Institutional Buildings

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

AMERICAN GOTHIC PLAYHOUSE

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

COMMONLY USED RESIDENTIAL BUILDING CODES

How to secure your property after a disaster

OPTIONAL INFORMATION GUARDING FLOORS, STAIRS, AND OTHER OPENINGS SELF INSPECTION CHECKLIST

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Chapter 6 ROOF-CEILING SYSTEMS

Certification: Building Plans Examiner. Exam ID: B3

TOWNSHIP OF TOMS RIVER ZONING OFFICE DECK CONSTRUCTION

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Page & Turnbull imagining change in historic environments through design, research, and technology

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Section A Roof Truss

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

ATI Evaluation Service A Division of Architectural Testing Certification Services

Residential Foundations and Basements

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

RESIDENTIAL BUILDING PERMITS

PUMP JACK SYSTEM AND ACCESSORIES

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Estimated Cost of Repair

Typical Finished Basement Details

Wisconsin Building Products Evaluation

CLACKAMAS COUNTY DEPARTMENT OF TRANSPORTATION AND DEVELOPMENT BUILDING CODES DIVISION R E S I D E N T I A L C O D E S U M M A R Y

PDmB, Inc. Definitions

Installation Instructions

Walking and Working Surface Checklist:

BUILDING PERMIT APPLICATION

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

Basic Requirements for Residential Plan Review _

Uniform Construction Code (UCC) Manufactured Homes. Modular Homes. Building Permit Application Package

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

The replacement or modification of existing windows shall comply with the following requirements:

March 14, Installation of Bay, Bow and Garden Windows

Residential Plan Routing Information

MUNICODE SERVICES LTD.

Typical Finished Basement Details

Ceiling Mounted Folding Attic Ladders Installation Instructions

Breakaway Walls

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Introduction...COMB-2 Design Considerations and Examples...COMB-3

MANUFACTURED HOUSING USED AS DWELLINGS

Residential Building Permits Information

8/18/14. Introduction to. Framing. Terminology and Concepts

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

SPIRAL STAIR KIT INSTALLATION MANUAL

DECKING INSTALLATION, CARE & MAINTENANCE INSTRUCTIONS MOISTURESHIELD.COM limited lifetime warranty

Common Problems with Walls

Superform Products Ltd.

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

TEST REPORT. Rendered to: INTEX MILLWORK SOLUTIONS, LLC. For: Rigid Cellular PVC Guardrail System Hampton RS40

2014 FLORIDA BUILDING CODE

Standard Comments Checklist

The Homeowner s Building Application Checklist for Constructing a Residential Sundeck

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Detached accessory structures that contain no conditioned floor area are exempt.

TJi 110 TJi 210 TJi 230 TJi 360 TJi. 560 JoiSTS. NEW! now featuring 18" and 20" TJi joists

The Stabilizer TM. Benefits. Supplemental support system for sagging beams and floor joists within a crawl space

Best Barns USA Assembly Book

How To Repair A Boat Landing Deck With A Boat Bed

Engineered Wood Foundations

Duchesne County Department of Building Safety

Transcription:

Mason County Building Department Residential Deck, Stair, Landing and Guard Detail Guard installed on all decks over 30" above orade. Vertical Pickets at handrail Graspable handrail on all stairways with 4 or more risers. Not less than 34" and not more than 38" vertically from nose of tread or walking surface. Handrail ends shall be returned or shall terminate in newel! posts or safety terminals. The greatest riser and the greatest stair tread shall not exceed the smallest by more than 3/8." Spaced so a 4" sphere cannot pass through. Minimum Guard Height 36" Stair nosing not less than 3/4" but not more than 1-1/4" on all solid risers unless tread depth is at least 11." Triangular opening formed by riser/tread/guard are permitted to be open so that a 6" sphere cannot pass through. 4"x4"x16" masonry block with asphalt shim. Indicate stringer size. Space per decking material Provide 4" wood/earth clearance here, 6" all other areas. Concrete footing 12" below grade when deck is greater than 30"above grade. See foundation info on reverse side. 12" min.. Indicate beam size/spacing. Provide positive connection post Indicate post size, spacing and base connector. h.li4-----i Ledger at wall: Decks shall be positively anchored for lateral & vertical loads. See Mason County deck ledger attachment detail. Decks shall be self supporting if connections cannot be verified during inspection. R502.2 Decks installed against manufactured homes must have beam support at this location. Typical Door with 3 Risers Landings are required on each side of each exterior door. Exception: A landing is not required with two or fewer risers. Landings shall not be more than 1-1/2" lower Than the top of the threshold. Exception: landing shall not be more than 7-3/4" lower than the threshold provided the door does not swing over the landing. CONSTRUCTION MATERIALS Decay resistant woods heartwood of redwood, cedar, black locust and pressure preservatively treated wood are all acceptable material for use in deck construction. Field applied treatment is not an acceptable method. Fasteners for pressure preservative treated woods shall be of hotdipped galvanized steel, stainless steel, silicon bronze or copper. Field cut ends, notches and drilled holes of pressure preservatively treated wood shall be retreated in the field in accordance with AWPA M4. IRC R319 & R320. Illuminate stairs with controls located at top and bottom of stairs. I" 36"min landing II Graspable Rail 34"min 38"max 36" min landing.. I Max. 7 3/4" rise]

Handrail Details 1 1 /2IN.MIN. 1'i,IN.T021N.t- HIN.MAX NOTE: Oth-0f ishapes may be acceptabl-= ti tl'l<l'f provide an equl\talent gripping surtaoo. Soi third par.'l"gra.ph ol Scc\ioo 1003.3.3"6. All stairways with 4 or more risers shall have at least one handrail. Such handrails shall be placed not less than 34" nor more than 38" above the nose of the treads and shall be continuous for the full length pf the flight. Handrail ends shall be returned or terminate in the newel post or safety terminals. Handrails adjacent to the wall shall have a space not less than 1 %" between the wall and the handrail. Circular handrails shall have an outside diameter of at least 1 %"and not more than 2." Handrails with a perimeter greater than 6 W shall provide a graspable finger recess on both sides. Handrails shall not project more than 4 %"on either side of the stairway. FOUNDATION SUPPORT SYSTEMS Decks 30TI or less above grade: Minimum 12"x12" manufactured pier. Deck 30" to 5'0" above grade: Minimum 14"x14" manufactured pier set 1T below grade. Decks greater than 5'0" above grade: Minimum 18"x18"x18" poured in place footing set 12" below grade. All deck posts shall have a positive post to footing and positive post to beam connection. ----D_e<?eight is measured at the lowest point within 5'0" beyond the walking surface of the deck. DECK PLAN EXAMPLE ONLY \ *BEARING REQ 'D EDR MFG, HOME \ ::::+- -- APPROVED JOIT HANGERS \\.\ \ \ --,_ - - r-- - -- -- -- r- 'G BUILDI \'A\\\\ \ \\\\\\\\ - " " *:!! ''- " w Kl;l nn u \'K... MA'rnRIALS '!'... bes< IBE [JOI rs & 8PAC NG ' r-..er? - - _,._... I\ "'-- " ""',,...,,_.,.cn:i ii "-'-' - c--,..._- tp ILW - m I " c * I *DES CF BE POSTS & PIER B JJCK SIZES & SPACI G L*DESCRIBE R M JOIST ''--*DE! CRIBE BE.i\M SIZE & SPAC ING * 2'0'' * * * 30'0" 'b -1 N

MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Mason County Bldg. Ill, 426 West Cedar Street PO Box 279, Shelton, WA 98584 www.co.mason.wa.us (360) 427-9670 Belfair (360)275-4467 Elma (360)482-5269 Deck Ledger Attachment Details & Specifications Please see Mason County Checklist item #56 and #69 for additional wood and fastener requirements Fastener spacing for solid sawn deck ledger to an existing band (rim) joist. (Deck Live Load = 40 psf & Dead Load = 10 psf) Joist Span 6'-0" and 6'-1 11 to 8'-1"to 1 O' 1" to 12' 1" to 14'-f' to 16' 1" to Less 8'-0H 1 O' -0" 12' -0" 14'-0" 16'.. Q" 18'-0" Connection Details On-Center Soacing of Fasteners 1/2" diameter lag screw wlth 15/32" 30 23 18 15 13 naximum sheathinq 1 /2 11 diameter bolt with 15/32" 36 36 34 29 24 naximum sheathin 1 /2" diameter bolt with 15/32" 36 36 29 24 21 naximui:n sheathing and %" stacked Nashe rs 11 21 18 10 19 16 Lag screw tips shall extend beyond the inside face of the band/rim joist Maximum gap between band/rim joist and ledger shall be 1 12" with spacer(s) Flashing shall be installed to prevent water intrusion at structural attachment Deck Ledger shall be minimum 2x8 pressure preservative treated No. 2 grade lumber Lag screws and bolts shall be staggered per diagram below typical spacing ---+-+---- 2"...-1--+'-11-- typical 1 @ <--.i "ffi 0 a.. lag screw, thru-bo!t, anchor with washer tag screws must be hot-. _ dipped galvanized or :. stainless steel only I D Ji I screw must penetrate " beyond band board j 1-112 shank length must extend thro,1gh a mlninium of 112,, a threadsl "" existing bat\d board "'"..,. stagger fasteners in 2 rows Please see typical diagrams on reverse for construction details.

Typical Construction Details Deck Ledger shall be 2x pressure preservative treated No. 2 grade lumber (2 x 8 minimum) Ledger shall be equal to (or greater than) joist sizes larger than 2 x 8 nominal 1 12" hot-dipped galvanized bolts and washers, staggered ' - -. "' '._... - "" "'1t. ;-' ;:... : Band joist existing 2x band board or 1-1 /4" min. manuf. solid rim joist remove siding at ledger prior to installation _,,.,------- continuous flashing vvith drip edge floor joist -- -11"'-+--=" -+-.,..f------ embed anchors 2-1/2" min. concrete or solld----1... -1 masonry wall.... deck joist...... 1/2" dia. expansion anchors -4 2x ledger board

DECK TO HOUSE LATERAL LOAD CONNECTION International Residential Code/WAC R507.2.3 R507.1 Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure and designed for both vertical and lateral loads. Such attachment shall not be accomplished by the use of toenails or nails subject to withdrawal. Where positive connections to the structure cannot be verified during inspection, decks shall be self-supporting. For decks with cantilevered framing members, connections to the exterior walls or other framing members, shall be designed and constructed to resist uplift in accordance with Table R301.5. LATERAL ATTACHMENT: Decks more than 30-inches above grade, measured 36-inches beyond the deck, Lateral load connections shall be permitted to be in accordance with Figure R507.2.3.. Hold down tension devices shall be installed in not less than 2-locations per deck, with an allowable stress design capacity of not less than 1500 pounds. OPTION: Lateral load connections may be installed in accordance with Figure R507.2.3(2), using holdown devices min. 750-pound capacity, evenly distributed and within 2-ft of each end of the ledger and attachments at shown. FLOOR SHEATHING NAILINGATl 6 IN. MAXIMUM ON CENTER TO JOIST WITH HOLD-DOWN HOLD-DOWN OR SIMILAR TENSION DEVICE DECK JOIST Note: This?!tail is applicable where qor JO!sts are parahel to deck JOIS.\S. FIGURE 507.2.3 DECK ATTACHMENT FOR LATERAL LOADS II 1 /Siding / _,,.- Sheathing " ;/.. l / / v.'s.ter tightness v I / / /Flashing fur V /...,.-[ Decking i-------'-=...; 1 i Deck joists Table R502.3.1(2) Approved joist hangers Pressure treated 2x looger with fasteners per!rc Tabl1e R.507.2 Floor joists _} Holdown device min 750# capacity at 4 locations, evenly distributed, along deck & 1 w!thin 2' of each '., end of the ledger. Holdown devices,, shall fully engage deck joist. "'-A fully threaded 3/8'' diameter lag screw predrllled wfmin 3" penetration to top plate, studs, or header. Figure R507.2.3(2)

MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT Mason County Bldg. Ill, 426 West Cedar Street PO Box 279, Shelton, WA 98584 www.co.mason.wa.us (360) 427-9670 Belfair (360)275-4467 Elma (360)482-5269 Permit/Policy Requirements for Construction/Repair of Decks Purpose: This policy is to assist in determining building permit requirements for decks. It applies to the construction, repair or alteration of deck structures and their associated components (guards, stairs, handrails) only. This policy does not apply to Piers, Docks or Balconies. Authority: Mason County Code 14.04.010 Uniform codes adopted (MCC) 2006 International Residential Code (IRC)/2006 International Building Code (IBC) Definitions: (as interpreted by Mason County for this purpose) Deck: An exterior floor system supported on at least two opposing sides by an adjoining structure and/or posts, piers, or other independent supports. Pier or Dock: A structure built over or floating upon the water that is used as a landing place for marine transportation or for commercial or recreational purposes. Adjacent Grade: The lowest point of elevation of the surface of the ground, floor or beach (measured from the walking surface) between the perimeter of the structure and a line 3 feet out from, and parallel to, the perimeter of the structure. Exterior Balcony: An exterior floor projecting from, and supported by, a structure without additional independent supports. Deck Repairs: Limited to the refinishing of existing components or the replacement of not more than 50% of the decking surface or 50% of the guard/railing components. Alteration: Change in size (footprint), replacement of any structural components (including but not limited to piers, footings, posts, beams or joists) or replacement of greater than 50% of the deck surface or guard/railing components. Procedure: A Building Permit is Required for construction/alteration of any deck greater than 30" above grade. EXCEPTIONS: When the walking surface of a deck is below 30" above adjacent grade (as defined above) it is considered exempt from a building permit.* Landings associated with a residential manufactured home permit that are 24 square feet or less will be considered exempt from a building permit.* *The structure must meet all construction standards and applicable egress requirements as set forth in the adopted building codes at the time of construction. The owner/applicant/contractor shall verify compliance with all setbacks prior to construction and verify compliance with all other regulations or permit requirements adopted by Mason County. ANY deck cover/roof requires a building permit Additional information: Mason County Building Department staff can assist with identifying code issues for deck construction, alteration/repair and replacement. Explanations and code references for many of the items listed in this policy can be found in the Mason County Residential Plan Review Checklist. Signature: MarkCore Date: Janury 20, 2009