Digital Clamp Axis Control for Hydraulic Molding Machines



Similar documents
Analog Command Value Card Type VT-SWKA-1

DC Electronic Loads 8500 series

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Safety technique. Emergency stop module BO 5988 safemaster

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Disturbance Recoder SPCR 8C27. Product Guide

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Features, Benefits, and Operation

OPERATION MANUAL VALVE CHECKER G

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Contents. Document information

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Designed for multi-injector endurance testing, the

Operation and Installation Manual

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Analog Servo Drive 25A8

MINI MCR-SL-R-UI(-SP)

Multifunction devices

Analog Amplifier Rexroth RA: Easy, user-friendly control of pumps and valves

Voltage Regulator SPAU 341 C. Product Guide

Example. Fluid Power. Circuits

Digital Single Axis Controller

T0118 T2118 T3118. Instruction Manual

Unidirectional Transmitter/ Receiver Units Introduction

Physical Specifications (Custom design available.)

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

LDG DTS-4/4R Desktop Coaxial Switch / Remote

mecotron Safety relay ESTOP-2 For emergency stop monitoring

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Frequency Converter Fv

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Digital electronic drivers type E-RI-PES integral-to-valve format, for variable displacement axial piston pumps with alternate P/Q control

Multi-Range Programmable DC Power Supplies 9115 Series

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

EXTERNAL DIMENSIONS AND PARTS

TwinCAT NC Configuration

RRV934. Multi-controller. Synco living

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Digital input modules

Single Channel Loop Detector

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

RS - SPM. Serial parallel translator module

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

OZW30. Central Unit SYNERGYR

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

TX OPEN RS232/485 module

Permissible ambient temperature Operation Storage, transport

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Quick Connect. quick - simple - efficient.

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

AP331A XX G - 7. Lead Free G : Green. Packaging (Note 2)

2.24. Pump Controller 704. Data Sheet

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Installation guide H A. HSI hardwired system interface

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Digital Pressure Measuring Instrument MDR480

WIND Power Technology: IMD Integrated Motor Drive

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

HERZ-Thermal Actuators

FM Radio Transmitter & Receiver Modules

COUNTERBALANCE VALVES

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

40.3. Control Relays and Timers

B/S/H/ Error codes and service programmes PH

Analog signal converters CC-E I/I Current / current isolators

Smart DeviceNet Remote I/O Terminals

with Electronic Assistant

PD 100A. Printing data system

1.44 kw Programmable DC Power Supplies XLN Series

Everything you need for protection scheme testing

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

DCS Input/Output Relay Card Series

Technical Information POWER PLANT CONTROLLER

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

TMS TANK MANAGEMENT SYSTEM

Transcription:

Industrial Hydraulics Electric rives and Controls Linear Motion and ssembly Technologies Pneumatics Service utomation Mobile Hydraulics igital Clamp xis Control for Hydraulic Molding Machines R 08 499/09.03 Replaces: R 08 499/06.03 1/08 Model VT-HC-PC-1X Series 1X Features ccepts digital SSI position feedback devices Six analog inputs predefined, voltage (± 10V, 0..10V) Three analog outputs predefined Enable input and Card OK output Eight predefined digital inputs Seven predefined digital outputs of the hydraulic axis. Valve configuration parameters are available to adapt the output for a wide range of hydraulic valve types ±10V output Front display for parameter display and 4 pushbuttons to access various parameters Serial interface RS232 evicenet communication vailable accessories: PC program BOC available on C-ROM or internet download. Interface cable: Cable set VT-HC-1X/03.0/HC-PC or standard 1:1 cable Further information: Product information see R 08 499-P Installation instructions see R 08 499-B Suitable card holders: 19 rack VT 19101, VT 19102, VT 19103 or VT 19110 (see RE 29 768) Open card holder CH64G-1X ( R 29 921) suitable for cabinet mounting only Connection adapter VT 10812-2x/64G (see RE 30 105)

2/08 Bosch Rexroth Corp. Industrial Hydraulics Model VT-HC-PC-1X R 08 499/09.03 Model code VT-HCPC 1X / V1 / 1 C 0 igital Clamp Series 10 to 19 (10 to 19: unchanged technical data and connection allocation) 0 = Without valve output stage 0 = Without Bus connection C = evicenet /CNopen* communication 1 = With isplay V1 = With BUS triggers * In preparation Functional description The PC is a digital control card for clamp control type applications. It includes proven control techniques and advanced options for controlling the hydraulic axis. Ultimately, the control system is bound to the mechanical and hydraulic limits of the machine. The PC is a tool for closed loop control that can define the performance limits of the machine. Results are a function of proper machine design, installation, environment and laws of physics. Overview The PC is a digital platform, industrial clamp controller. It optimizes the control of a hydraulic axis for velocity and force control. Velocity profiles are controlled completely by use of closed loop position control. n advanced position command profile is calculated automatically based on the operator input velocity profile. Because the PC is a position control device it requires a position feedback transducer. Both 0 to 10 VC analog and SSI digital types are supported. The PC uses constant acceleration type ramping to allow smooth acceleration of the clamp. Position dependant braking technology is used so that even the most demanding systems can be decelerated in the shortest time possible, smoothly and with superb repeatability. The PC includes force-limiting control that can be configured to work with 1 or 2 pressure transducers or a load cell. dvanced control techniques like ctive amping allow precise closed loop control of the most demanding low-naturalfrequency systems. The velocity profile and force profiles may be controlled with one proportional directional type hydraulic flow control valve, or using separate valves for flow and pressure. The PC includes evicenet communications protocol that allows access to all parameters directly from a PLC or computer. ll sequence triggers are transmitted to the PC over a evicenet bus system. Motion profile set points are normally transferred into the PC from a PLC or computer. The profile set points may also be entered into the card using Bosch Rexroth BOC software. Critical process data is acquired and stored during each cycle. The stored data is available for machine controller statistical process control functions through the evicenet communications link. Operational description The PC controller is a complete hydraulic clamp axis control solution. clamp motion profile is created from parameters that are entered by the machine operator into a machine sequential logic controller. Parameters are loaded from the machine sequential logic controller into the card through a evicenet communications interface. ll clamp cylinder motion parameters are then stored on the card. Parameter changes may be individually loaded into the card, or the entire profile loaded at one time. The card maintains the last saved profile in non-volatile flash memory. single clamp motion profile is stored on the card. Multiple profiles may be stored in the machine sequential logic controller and any one selected to load into the card. Handshaking to sequence the axis control is through the evicenet communications interface. single discrete input is required to enable the card prior to any other commands, and three additional discrete inputs may be combined for additional safety functions. The PC controller includes the following control features and functionality. Completely Closed Loop Control ll segments of the motion profile are controlled by implementation of closed loop position control of the clamp cylinder. ctive damping technology allows stable and smooth closed loop control of even springy, low natural frequency systems. t the start of clamp motion the internal position command is set equal to the current cylinder position feedback and then ramped toward the next segment s start position. The rate of movement of the position command corresponds to the velocity command in the current profile segment. Each step in the profile is initiated when the internal position command reaches a segment start position as defined in the profile. Repeatability of the profile is insured because the internal position command is moved at a rate controlled by the internal PC clock, and the cylinder follows the command profile. This type of system is used because it is relatively unaffected by changes in friction, oil temperature, and, other system variables. Smooth acceleration of the clamp to the selected traverse velocity is controlled by a constant acceleration ramp. eceleration of the clamp to slow velocity is controlled by use of position dependant braking technique that assures fast, smooth, and repeatable slowdown.

R 08 499/09.03 Model VT-HC-PC-1X Industrial Hydraulics Bosch Rexroth Corp. 3/08 Functional description (continued) Mold Close Profile two-segment profile is provided to close the mold; the traverse segment and the mold protect segment. maximum closed or open loop pressure limit may be set for each profile segment. timer (start close delay) is available to delay the start of the mold close profile and allow the hydraulic pump system time to build pressure, which prevents undesirable initial windup of the closed loop control. There is a discrete output available to indicate when mold touch position is achieved. The profile may optionally be adjusted to stop the clamp during the mold protect segment (before mold touch) using the pre close stop position. Two additional final close velocity segments are available to then complete the closing profile. Final close is triggered independently of the closing profile. Tonnage Profile two-segment profile is provided for mold closed pressure control, the tonnage segment and the low-hold segment. The tonnage segment is started automatically when the tonnage start position is reached during the mold close or final close profile. Tonnage pressure control may be closed or open loop. For toggle clamp applications there is a discrete output available to indicate when tonnage position is achieved. The flow valve output may be limited to separate open loop values during the tonnage and low-hold pressure control segments. ecompress Prior to opening the mold the clamp cylinder(s) must be decompressed to prevent hydraulic shock. decompress segment is provided with an adjustable pressure set point and decompress rate control. discrete output is provided to indicate when the pressure has decreased below the decompress set point. The decompress complete discrete output is a permissive that is required to allow the clamp to begin the mold open profile or the jog open function. Mold Open Profile three-segment profile is provided to open the mold; the breakaway segment, the traverse segment and the open slow segment. maximum open loop pressure limit may be set for each profile segment when using a separate pressure control valve. timer (start open delay) is available to delay the start of the mold open profile and allow the hydraulic pump system time to build pressure, which prevents undesirable initial windup of the closed loop control. Jog Functions In addition to the closed loop profile control there are two open loop jog modes, open and close. The valve outputs may be preset to an independent value for each jog mode. There are separate increasing and decreasing ramp adjustments for each output in jog mode. Typical applications of these modes are for manual operation of the clamp (setup function). The machine sequential logic controller triggers each jog mode through the evicenet interface. pplications The PC is configured to control clamp type applications and all parameters are labeled to be recognizable in clamp applications. There is, however, many other applications that could benefit from the quality of control afforded by the PC. Typical applications include: Mechanical handling devices Lift and Transfer machines Powder metal presses ngular position for rotary axis Shuttle and Transport axis Configuration Options The card can be applied in one of two basic configurations depending on the hydraulic system. 1. Closed loop velocity profile and closed loop pressure control using one proportional directional valve and one analog valve output. This type of system will control the clamp velocity profile and closing pressure limit using one proportional directional control valve. The available dynamic response using this type of system is higher than systems that use separate valves for flow and pressure control. Mold protect pressure typically can be a lower value using a single control valve system. 2. Closed loop velocity profile and either closed loop or open loop pressure control using one proportional directional or flow control valve for the velocity profile and one proportional pressure control valve for the pressure control. There are two analog valve outputs available for this configuration. This configuration does not require as high dynamic response from the proportional directional control valve as the single valve configuration. Mold protect pressure control will not be as dynamic due to limitations of separating flow and pressure functions into multiple valves, and inherent dynamic limitations of proportional pressure control valves. lternatively, the PC may be configured so that the second valve output is controlled directly by the machine logic controller instead of the internal pressure profile Front panel operation The front display is used in conjunction with the 4 push buttons to display and change operator parameters. ccess is given to the following operator parameters: Mold close profile Tonnage pressure profile ecompress Mold open profile For safety reasons, set-up and configuration parameters are not accessible through the front panel. Fault messages will be displayed if they occur. PC program BOC The PC program BOC makes it possible to configure, parameterize and perform diagnostic functions on the VT-HC-PC-1X via a serial interface (RS232). C ordering code: SYS-HC-BOC-01 or download via the internet, address www.boschrexroth.com(navigation: Industrial Hydraulics -> Products and Solutions -> Product Overview -> igital open and closed loop controls -> HC -> PC program BOC

4/08 Bosch Rexroth Corp. Industrial Hydraulics Model VT-HC-PC-1X R 08 499/09.03 Block circuit diagram: VT-HC-PC-1X (Configuration 1) V Position Transducer (0-10 V or SSI igital) 0% Proportional Clamp Valve +-10 V O2 (OUT2) Spare nalog Output +/-10V or 0-10V I4 (PT#2) I2 (PT#1) SSI clk(+) SSI clk(-) SSI data(+) SSI data(-) Transducers 0-10 V V P P I5 (0-10V) O1 (OUT1) d32(+) b28(-) b14(+) b16(-) b6(+) b8(-) f4 f6 f8 f10 b18(+) b20(-) d30(+) b28(-) pplication Valve Output Cylinder rea Ratio Position pplication Valve Output Clamp Velocity Profile Slowdown Setpoint eceleration VT-HC-PC-1X/V1/1-C-0 (Configuration 1) Clamp Profile Net Interface igital Outputs igital Inputs f32 f30 f28 d22 d20 d26 z22 z24 z26 z28 f2 d18 d2 d4 d6 CNH CNL CN drain OK O1 O2 O3 O4 O5 O6 O7 Enable I1 I2 I3 PLC Communications Card OK t Mold Touch Following Error Fault ctive t Open Position t Tonnage Position t Closing Force t ecompress Ejector Extend Permit Enable Soft Stop uto (Run) Close Permit Typical clamp circuit using one proportional control valve for velocity and pressure control and the PLC to control output O2 (Out2) directly for additional functions if required.

R 08 499/09.03 Model VT-HC-PC-1X Industrial Hydraulics Bosch Rexroth Corp. 5/08 Block circuit diagram: VT-HC-PC-1X (Configuration 2) Transducers 0-10 V V P P Proportional Relief Valve 0-10 V V Position Transducer (0-10 V or SSI igital) 0% Proportional Clamp Valve +-10 V O2 (OUT2) I4 (PT#2) I2 (PT#1) SSI clk(+) SSI clk(-) SSI data(+) SSI data(-) I5 (0-10V) O1 (OUT1) d32(+) b28(-) b14(+) b16(-) b6(+) b8(-) f4 f6 f8 f10 b18(+) b20(-) d30(+) b28(-) pplication Valve Output Cylinder rea Ratio Position pplication Valve Output Clamp Velocity Profile Slowdown Setpoint eceleration VT-HC-PC-1X/V1/1-C-0 (Configuration 2) Clamp Profile Net Interface igital Outputs igital Inputs f32 f30 f28 d22 d20 d26 z22 z24 z26 z28 f2 d18 d2 d4 d6 CNH CNL CN drain OK O1 O2 O3 O4 O5 O6 O7 Enable I1 I2 I3 PLC Communications Card OK t Mold Touch Following Error Fault ctive t Open Position t Tonnage Position t Closing Force t ecompress Ejector Extend Permit Enable Soft Stop uto (Run) Close Permit Typical clamp circuit using two proportional control valves, one for direction and velocity control and the second for clamp pressure control.

6/08 Bosch Rexroth Corp. Industrial Hydraulics Model VT-HC-PC-1X R 08 499/09.03 Technical data (for applications outside these parameters, please consult us!) Operating voltage U B 24 VC Functional range: Upper limiting value U B (t) max 35 V Lower limiting value U B (t)min 21 V Current consumption I max 150 m Fuse I s 4 T igital inputs Voltage Log 0(low) 0 to 5V Log 1 (high) 15V to U B igital outputs Voltage Log 0(low) 0 to 5V Log 1 (high) 15V to U B I max = 30 m nalog inputs Range U 0 to 10V or ± 10V (configurable) Input resistance R e 200 kω, > 10MΩ for I1 Resolution 5 mv for range ± 10V 2.5 mv for ranges 0 10V Non linearity < 10mV nalog outputs O1 Output voltage U ± 10V Output current I max 20 m Load R min 500 Ω Resolution 1.25 mv (14bit) Residual ripple ± 15 mv (without noise) O2 Output voltage U ± 10V Output current I max 10 m Load R min 1 kω Resolution 10 mv (11bit) Residual ripple ± 25 mv (without noise) Sampling interval T 2 ms Serial interface Connection type RS232 (front plate), -sub socket 64 pin blade connector, IN 41 612, form G Card dimensions Eurocard 100 x 160 mm, IN 41 494 Front plate dimensions Height 3 U (128.4 mm) Width soldering side 1 HP (5.08 mm) Width component side 7 HP Permissible operating temperature range ϑ 0 to 122 F (0 to 50 C) Storage temperature range ϑ 4 to 158 F ( 20 to +70 C) Weight m 0.2 kg Note: For details regarding the environmental simulation test covering EMC (electro-magnetic compatibility), climate and mechanical loading see RE 30 143-U(declaration regarding environmental compatibility)

R 08 499/09.03 Model VT-HC-PC-1X Industrial Hydraulics Bosch Rexroth Corp. 7/08 Connection diagram connector Pin Row z Row b Row d Row f 2 n.c. I3+: (Spare) I1: Soft Stop O7: Ejector Extend Permit 4 n.c. I3-: (Spare) I2: uto (RUN) SSI clock +: Clamp cylinder FB 6 n.c. I2+: FB#1 I3: Close Permit SSI clock -: Clamp cylinder FB 8 n.c. I2-: FB#1 I4: (Spare) SSI data +: Clamp cylinder FB 10 Shield I1+: Valve#1 spool position 1) I5: (Spare) SSI data -: Clamp cylinder FB 12 n.c. I1-: Valve#1 spool position I6: (Spare) I8+: Jumper to O3 (Velocity Close) 14 n.c. I4+: FB#2 I7: (Spare) I8-: Jumper to nalog GN 16 n.c. I4-: FB#2 n.c. n.c. 18 n.c. I5+: Clamp cyl. FB Enable n.c. (optional) (optional) 20 n.c. I5-: Clamp cyl. FB O1: t Mold Touch n.c. (optional) (optional) 22 O3: t Open Position I6+: Jumper to O3 Card OK n.c. (Velocity Close) 24 O4: t Tonnage Position I6-: Jumper to nalog GN n.c. n.c. 26 O5: t Closing Force O3: Traverse Velocity O2: Following Error Fault n.c. Command ctive 28 O6: t ecompress nalog GN n.c. CN drain 30 U B : +24V 10 V O1: Valve CM Single CNL or Velocity 32 L0: 0V + 10 V O2: Valve CM Clamp CNH 1) This input has an input resistance of R e > 10 MΩ (For monitoring purposes only) n.c. is not connected Connection diagram of the -sub socket on the front plate Receive data (RS 232) Send data (RS 232) 1 6 GN 9 5

8/08 Bosch Rexroth Corp. Industrial Hydraulics Model VT-HC-PC-1X R 08 499/06.03 Unit dimensions: dimensions in inches (millimeters) 1.59 (40.3) 0.08 (2) + 3.94 (100) 3.46 (88) 5.05 (128) 3U 5.05 (128) ENBLE I1 I2 I3 I4 I5 I6 I7 I8 OK O1 O2 O3 O4 O5 O6 O7 UP OWN 0.28 (7) X1X2 ENTER COM RS232 ESCPE 6.77 (172) 7.09 (180) 0.08 (2) 0.39 (10) 8HP 1.59 (40.3) Engineering / maintenance guidelines / additional functions Use low-capacitance cables. Make cable connections without intermediate connections whenever possible. Control electronics should be isolated from electromagnetic noise sources (e.g. Variable frequency drives). Power wiring should not be routed in the vicinity of control electronics. Power wiring should not be routed in the vicinity of control wiring or cables. Route sensor lines separately. Maintain a distance of at least 1 meter from antenna lines, RF devices and radio equipment. When using differential inputs switch both inputs on and off at the same time. When switching signal inputs, use dry circuit rated relays with gold-plated contacts (low voltages, low currents) lways shield all analog signal lines. Connect shields at the card end only, connecting to the Shield terminal, and leave the other end open to prevent ground loops. Connect to an appropriate system ground using stranded copper wire (min 2.5mm2 / 12 WG)! The system ground is an essential component of the EMC protection for the controller card. The ground provides a path for noise that could otherwise enter the controller card through the signal and power supply lines. Noise is bypassed only if the system ground does not couple noise into the controller card. Rexroth also recommends shielding solenoid wiring. o not use logical signals from the controller card (e.g. OK signal) for switching machine safety circuits (see European Norm Safety Requirements for Fluid Power Systems and Components EN982:1996). Bosch Rexroth Corporation Industrial Hydraulics 2315 City Line Road Bethlehem, P 18017-2131 Phone (610) 694-8300 Fax (610) 694-8467 www.boschrexroth-us.com The data specified above only serves to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The details stated do not release you from the responsibility for carrying out your own assessment and verification. It is important to remember that our products are subject to a natural process of wear and aging. ll rights reserved. No part of this document may be reproduced or stored, processed, duplicated, or circulated using electronic systems, in any form or by means, without the prior written authorization of Bosch Rexroth Corporation.