2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch



Similar documents
OPERATING INSTRUCTIONS

Fused Spur Time Switch

5W LED Energy Saver PIR Bulkhead

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

Wireless 7 Day Programmable Room Thermostat

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Power Socket (2 Gang)

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

13 SERIES. Electronic step relays A

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

15 Series - Electronic step relay and dimmer. Features SERIE

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

EBDSPIR-PRM, EBDSPIR-PRM-IP

Problem / Solution. The problem:

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Installation Guide. DEVIreg 530. Electronic Thermostat.

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

HERZ-Thermal Actuators

Product Catalogue August Energy management Switches and controls

Decorative Metal Wiring Accessories in Assorted Plate Finishes

48 SERIES Relay interface modules 10 A

Wiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling units

Drayton Digistat +2RF/+3RF

Single Channel Loop Detector

CX Zoner Installation & User Guide

49 Series - Relay interface modules A. Features

GUIDE TO THE AM2 EXAM

SERVOMECH Linear Actuators

Aerona Air Source Heat Pumps

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ACS-30-EU-EMDR-10-MOD

Product and functional description

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Series 8146/5-V37 and Series 8150/5-V37

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Brio-Rmanual:Cursamanual.qxd 08/04/ :25 Page1

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Emergency lighting units EM powerled

Section B: Electricity

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Modular I/O System Analog and Digital Interface Modules

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Universal control module for motorized devices

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Mureva Assembly surface mounted wiring devices

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

EGSTON Standard E2xFxWx 12W

Solid as a rock Soliroc

Operating Instructions. Room temperature controller

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Advantium 2 Plus Alarm

38 Series - Relay interface modules A

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

DEVIreg 330 (+5 to +45 C)

T7079A,B Solid State Remote Temperature Controllers

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Safety technique. Emergency stop module BO 5988 safemaster

EBDSPIR-DD, EBDSPIR-DD-IP

New Media Power Socket Outlets. New Media Power Socket Outlets

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Smile. The All-In-One Heating Controller

Adjustment functions for both span and shift have been incorporated

HMI display Installation Guide

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

E-STOP relays, safety gate monitors

Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) IP66. Improved catch.

RF Maestro Local Controls

Contact Details. Please note that some of the contact details on this PDF document may not be current.

38 Series - Relay interface modules A


FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

1 light dimming module

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

User s Manual Before using the inverter, you need to read and save the safety instructions.

SPEED CONTROL SYSTEM

VARI-DRIVE NEMA1 / IP20 SCR Variable Speed DC Motor Controls

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

ABB i-bus KNX Fan Coil Controller FC/S 1.1

INFRARED QUARTZ WALL HEATER

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

3 IN 1 BATHROOM HEATER

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

INSTALLATION & SERVICE MANUAL. Display Panel

Instruction Manual Differential Pressure Transmitter

Transcription:

2 Wire Electronic Time Delay Switch Cat No. DS1 2 Wire Slave Switch Cat No. DSS 3 Wire Electronic Time Delay Switch Cat No. DS2 Installation & Operating Instructions

DS1/DSS Instructions for Installation and Use If you have a DS2 please refer to separate instructions on page 10. 1 Tough flame retardant polycarbonate plate fits a standard single gang wall box 16mm deep. Illuminated push button. Optional push-in screw covers supplied Fig 1 Front of DS1 and DSS 1. General. The DS1 is a time delay switch with an illuminated push button, which replaces a standard single gang plate switch on a box 16mm deep. The illumination guides the user to the push button and once this is pressed the lights under control are switched on for a period from approximately 10 seconds to approximately 10 minutes adjustable by internal potentiometer. For situations requiring two-way and intermediate switching DSS s can be used in conjunction with a single DS1. Section 5 shows how these can be used in retrofit without wiring modifications and section 2b shows how they should be wired in new installations.

2 Delay time adjuster centre scale gives approximately 5 minutes (linear scale). Fig 2a Rear of DS1 Fig 2b Rear of DSS

3 2a. Installation (Replacement of Single ON/OFF Switches Only). FOR INSTALLATION OF DS1 & DSS s IN 2 WAY AND INTERMEDIATE SWITCHING CONFIGURATIONS SEE SECTION 5. IF IN DOUBT CONSULT AN ELECTRICIAN. SWITCH OFF MAINS ELECTRICITY. Set the delay time adjuster on the DS1 to minimum (fully anticlockwise see fig 2a) to enable initial testing during commissioning. Remove the existing light switch and transfer the two wires to the DS1 connecting them to terminals L and SL in either position. If two wires were connected to either terminal on the original switch they must be kept together and connected to either L or SL on the DS1. Do not disturb any earthing wire connected to the wallbox terminal. Ensure both terminals are tight before screwing the two plate fixing screws supplied home sufficiently to locate the DS1 securely to the wall box. Turn ON the mains supply. 2b. New Installation of a DS1 and Up to 10 DSS s. In a new installation the DS1 and DSS s can be wired to give control of a single lamp load by any of the switches. This is shown in fig 3. Fig 3

4 If only one DSS is required then connect the mains supply live (L) to LIN on the DSS and leave the SLAVE connection formerly going to the second DSS open circuit. Further DSS s can be added by copying the circuit connections shown in Fig 3 between the two DSS s. The LIN of the second DSS is connected to LMASTER of the third and LIN of the third to L (mains supply live) and so on for further DSS s. 3. Commissioning. Press the push button and the light(s) under control should come ON for approximately 10 seconds. During this time the neon behind the push button switches OFF. If the lamps under control are fluorescent they will not switch ON immediately and the light intensity may be reduced initially. If there are DSS s installed as well repeat this test at each switch. Having established that the DS1 and any DSS s are working correctly the mains supply should be turned OFF and the two fixing screws removed from the unit. The DS1 can then be pulled away from the wall to enable access to the delay time adjuster (see fig 2a). The delay time can then be set to the required level and the DS1 fixed to the wall using the two fixing screws. The push-in screw covers can now be fitted if required. The mains supply should be turned ON and the push button pressed to ensure the delay time is correct. 4. Operation. Whenever light is required press the closest push button and the light(s) under control will remain ON for the set delay time. 5. Replacing 2 Way and Intermediate Switches. This involves wire identification and tracing. Switch installation should be left to a competent electrician who will be able to relate the circuit diagrams shown in figs 4 to 11 to the practical installation.

There are two main ways of achieving 2 way switching Strapping Cable and Remote Live Access. The circuits for these are shown in figs 4 and 5. They are shown with a single intermediate switch giving 3 way switching. Further intermediate switches can be added. 5 In keeping with BS schematic code wires shown in direct cross over (i.e. +) are not connected electrically. Fig 4 Strapping Cable & One Intermediate Switch Fig 5 Remote Live Access & One Intermediate Switch

A DS1 and two DSS s can be used to replace these switches for both wiring systems to give time delayed momentary switching at all three switch locations. The DS1 should not be located at a former intermediate switch location. The circuits for both wiring systems with the replacement switches are shown in figs 6 and 7. No wiring alterations are required but to establish which wires are connected to which terminals the wires must be identified and traced. An in-line connector is required for the Strapping Cable System to provide continuity for the SL connection. 6 Fig 6 Replacement Delay Switches fitted to circuit shown in fig. 4 In keeping with BS schematic code wires shown in direct cross over (i.e. +) are not connected electrically. Fig 7 Replacement Delay Switches fitted to circuit shown in fig. 5

Further DSS s can be added to replace any further intermediate switches in the system. If there are no intermediate switches (2 way switching) the before and after connections for both systems are shown in figs 8 to 11. Note that an in-line connector is required for the Strapping Cable System to provide continuity for the SL connection. 7 Fig 8 2 Way Switching Strapping Cable Fig 9 2 Way Switching Remote Live Access

Fig 10 Replacement Delay Switches fitted to circuit shown in fig. 8 In keeping with BS schematic code wires shown in direct cross over (i.e. +) are not connected electrically. 8 Fig 11 Replacement Delay Switches fitted to circuit shown in fig. 9

9 6. Specifications DS1. i Conforms to Directives: ii Permissible Loads: 73/23/EEC & 89/336/EEC Filament lamps 1.5kW Low voltage 20 to 200W, Resistive 2kW Not suitable for fluorescent or low energy lighting. iii Operating Ambient Temperature Range: -10 C to 40 C iv Operating Voltage: 220 to 240V 50Hz v Delay Time: 10 sec to 10 min (nominal) adjustable by tamperproof potentiometer (nominal times vary by up to ±33%) vi Terminations: Suitable for 1mm 2 and 1.5mm 2 solid conductors and stranded equivalents vii Minimum Box Depth: 16mm viii Standby Consumption: Less than 2 VA 7. Specifications DSS. i Conforms to Directives: 73/23/EEC & 89/336/EEC ii Operating Ambient Temperature Range: -10 C to 40 C iii Operating Voltage: 220 to 240V 50Hz iv Terminations: Suitable for 1mm 2 and 1.5mm 2 solid conductors and stranded equivalents v Minimum Box Depth: 16mm vi Standby Consumption: Less than 2 VA

DS2 Instructions for Installation and Use If you have a DS1 working alone or with one or more DSS s please refer to separate instructions on page 1. 10 Tough flame retardant polycarbonate plate fits a standard single gang wall box 16mm deep. Illuminated push button. Optional push-in screw covers supplied Fig 1 Front of DS2 1. General. The DS2 is a time delay switch with an illuminated push button, which fits on a standard single gang wall box 16mm deep. It requires a neutral connection and provides delay times between 10 seconds and 2 hours adjustable by internal potentiometer and range switches. It can be used to control lamps and other appliances within the limits set out in the specifications section. Several DS2 s can be wired in parallel to control a single load but the DS2 cannot be used in conjunction with DSS s.

Time range selector Delay time adjuster. 11 Fig 2 Rear of DS2 2. Installation. IF IN DOUBT CONSULT AN ELECTRICIAN. SWITCH OFF MAINS ELECTRICITY. Set the switch position to 1 ON, 2 OFF and the delay time adjuster to minimum (fully anti-clockwise see fig 2) to enable initial testing during commissioning. Connect the three wires to the appropriate terminals. Mains Live L Switch Live SL (to load) Neutral N If two wires were connected to any terminal on the original switch they must be kept together and connected to the appropriate terminal on the DS2.

12 Make sure that the wallbox is earthed if it is metal. Ensure that all three terminals are tight before screwing the two plate fixing screws supplied home sufficiently to locate the DS2 securely to the wall box. Turn ON the mains supply. If further DS2 s are required to control the same load they must have all corresponding terminals wired in parallel with these on the first DS2. 3. Commissioning. Press the push button and the light(s)/appliance(s) under control should come ON for approximately 3 seconds. During this time the neon behind the push button switches off. If the load under control is low energy or fluorescent lamps they will not switch ON immediately and the light intensity may be reduced initially. Having established that the DS2 is working correctly the mains supply should be turned OFF and the two fixing screws removed from the unit. The DS2 can then be pulled away from the wall to enable access to the delay time adjuster and 2 gang range switch (see fig 2). The delay time can then be set to the required level by setting the 2 gang range switch according to table 1 and then adjusting the delay time adjuster. The DS2 can then be fixed to the wall again using the two fixing screws. The push in screw covers can now be fitted if required. The mains supply should be turned ON and the push button pressed to ensure the delay time is correct. 2 Gang Range Switch Position Adjuster Min. Adjuster Max. 3 sec. 30 sec. 12 sec. 2 min. 1 min. 30 sec. 16 min. 30 sec. 12 min. 30 sec. 2hrs. 10 min. All delay times accurate to ±25%. Black switch lever.

13 4. Operation. Whenever light or appliance operation is required press the push button and the light(s)/appliance(s) under control will remain ON for the set delay time. 5. Specifications. i Conforms to Directives: 73/23/EEC & 89/336/EEC ii Permissible Loads: Filament lamps 1.5kW Low voltage 20 to 200W Heating 2kW Inductive 4A Motor 1hp Not suitable for fluorescent or low energy lighting. iii Operating Ambient Temperature Range: -10 C to 40 C iv Operating Voltage: 220 to 240V 50Hz V Delay Time: 4 ranges selectable by tamperproof two gang switch:- 3 sec. to 30 sec. (nominal) 12 sec. to 2 min. 4 sec. (nominal) 1 min. 36 sec. to 16 min. 31 sec. (nominal) 12 min. 26 sec. to 2hrs. 12 min. (nominal) All adjustable by tamperproof potentiometer (nominal times vary by up to ±25%) vi Terminations: Suitable for 1mm 2 and 1.5mm 2 solid conductors and stranded equivalents vii Minimum Box Depth: 16mm viii Standby Consumption: Less than 2 VA

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515. Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside the UK. All shipping costs are to be paid in advance before a replacement is sent. 14

For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com Designed and manufactured in the U.K. 67.058.91 (issue 2). Zerofour May 2013