EDS / EFS Series Control Stations



Similar documents
EDS / EFS Series Control Stations

GUE, GUB Junction Boxes

FLB Series Circuit Breakers and Enclosures

Explosion-Proof Electric Unit Heaters

Scraper Passage Indicator. Electrical Indicator. Features

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

STB Series Enclosures

8146/5 Series Breaker Panelboards

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

FITTINGS: CAST DEVICE BOXES. Applications. Illustrated Features

Plugs and Receptacles

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

WE-350 Series ¼ Turn Electric Actuator

Cable-Gard Static Discharge Reels

A. Shop Drawing submittals shall include, but not be limited to, the following:

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

TorqPlus TM Electric Valve Actuators and Controls

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Screw Plug Immersion Heaters

Lighting Accessories Hazardous and Non-hazardous

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

Fire Alarm System Accessories

GUTTER MACHINE CONTROLS STANDARD

Myers Hubs. The broadest, most complete offering for terminating Rigid/IMC to a box or enclosure

Intrinsically Safe Barrier Relays NY2 and 8501TO

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

SBM Control & Transfer Switch Rotary switches for circuit breaker control, motor control or instrument transfer. Features and Benefits Applications

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE

AC METRIC (IEC) MOTORS THREE PHASE

Manual Switches Series 2 Pushbutton Switches and Indicators

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Pilot and Signaling Devices. Section 9. Control Catalog 9-1

Hazardous location controls and apparatus. Getting you closer. ACE series explosionproof variable frequency drives

Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB

Diesel Engine Driven Generators Page 1 of 6

Owner's Copy December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

Comparison of NEMA and IEC schematic diagrams

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

MODEL HSR-007 Direct Drive Rolling Steel

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors

B-Series Temperature Switches

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Centro-Matic Automatic Lubrication Systems System Controls

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Type 1, 3, & 3R Enclosures

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

DESIGN CLARIFICATION (DC)

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

TS93 EMR T/PT/TDE. Surface applied door closer

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

Class 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015

Worcester DS/DM Series UltraSwitch Switch box

INDUSTRIAL CONTROLS. APEM, PO BOX 8288, HAVERHILL, MA USA TOLL FREE: (877) FAX: (781)

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

Compact pressure switch Flameproof enclosure Ex d Model PCA

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Mini USB and USB 2.0-IP67 Connector System

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Generator DoCKInG StatIonS

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Control and Distribution Boxes made of Stainless Steel Series 8150

Electronic, Digital and Mechanical Vibration Switches

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

General 1-2-Opto-electronics Safety Switches 4-Emergency

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

Switches SWITCHES SWITCHES

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Eaton Fuller Heavy Duty Transmissions Illustrated Parts List FS-5005C March 2003

PARTS MANUAL EH12-2 ENGINE. Model. PUB-EP5713 Rev. 7/99

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

V1504 Vertical Platform Lift OWNER S MANUAL

MONITOR SECTION INDEX

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

TABLE-TYER / TABLE-TYER SS POWER STRAPPING MACHINES 04/12/07

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

Cable/Conduit Conversion

4-Speed Kick Start Kit

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

V1504 Vertical Platform Lift OWNER S MANUAL

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Explosion proof enclosures

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Transcription:

EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Applications: Factory sealed enclosures are installed in a rigid metallic conduit system for surface mounting adjacent to or remote from equipment being controlled and are used: To prevent arcing of enclosed device from causing ignition of a specific hazardous atmosphere or atmospheres external to the enclosure In industrial areas such as chemical plants, oil and gas refineries, paint and varnish manufacturing plants, gasoline bulk loading terminals, grain elevators, grain processing industries, coal processing or handling areas, or metal handling or finishing areas where atmosphere may contain hazardous gases and/or dust In non-hazardous areas where sturdy, durable enclosures are required In conjunction with magnetic starters or contactors for remote control of motors Manual motor starting switch enclosures are used: For manual starting of small AC or DC motors To provide manual starting and stopping and, in the case of units with heaters, motor running protection Features: Factory sealed devices have many distinct advantages: Reduce installation problems Eliminate external seals Lower installation costs Improve safety Are used with general purpose snap and pushbutton type switches Standard neoprene covers for front operated pushbuttons. Prevents accumulation of dirt and entrance of water around operating shafts Mounting lugs and taper tapped hubs with integral bushings Large machine screws for fastening covers to bodies Lockout provisions on front operated pushbutton (marked "STOP" and "OFF") and selector switch covers Lockout hole for padlock having /4" hasp is provided when used with covers for front lever and side rocker type operation Close tolerances in machining of wide, mating flanges and journalled shafts and bearings for front button operation, produces flametightness of enclosure joints On enclosures with front lever and side rocker type operating handles, threaded type shafts and bushings are used to ensure flametightness Dead end (EFS or EDS) or through feed (EFSC or EDSC) hubs /2" to " sizes When STOP is indicated, button is automatically red. When START is indicated, button is automatically green. Otherwise, black buttons are standard. Certifications and Compliances: NEC/CEC: Class I, Division & 2, Groups B*, C, D Class II, Division, Groups E, F, G Class II, Division 2, Groups F, G Class III NEMA/EEMAC:, 7B*CD, 9EFG UL Standard: 20 CSA Standard: C22.2 No. 0 Standard Materials: Bodies Feraloy iron alloy; copper-free aluminum Front operated pushbutton and pilot light covers Feraloy iron alloy Side operated type pushbutton covers copper-free aluminum Shafts stainless steel Shaft bushings stainless steel Rocker handle and pushbutton guards type 6 / 6 nylon Sealing enclosures copper-free aluminum Standard Finishes: Feraloy iron alloy electrogalvanized and aluminum acrylic paint Copper-free aluminum natural Type 6 / 6 nylon black Stainless steel natural Options: The following special options are available from the factory by adding suffix to : Description Suffix Momentary red emergency STOP button front operated mushroom button, breaks normally closed contacts only... S Lockout provision on front operated pushbutton cover (standard on buttons marked "OFF" and "STOP")... S5 For 24 VDC operation on pilot lights... S00 Three-position selector switches with modified operation: Momentary contact clockwise operation, spring return to center, maintained contact counter-clockwise operation S64 Momentary contact counter-clockwise operation, spring return to center, maintained contact clockwise operation... S65 Bodies and covers (single and two gang units) copper-free aluminum... SA Where indicated in the catalog listings, EDS units suitable for Class I, Division, Group B usage can be supplied, add suffix -GB, EFS units are suitable for Class I, Division, Group B as standard... GB Maintained red emergency STOP button with lockout front operated mushroom button breaks normally closed and makes normally open contacts (push to stop), lockout standard (will not fit with a pilot light if transformer is required)... S769 Spring return to center from right and left... S842 EDS bodies and factory sealed cover and device sub-assemblies are available for field assembly (see page 52). *See suffix GB in Options section. www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 206 Eaton

EDS / EFS Series Control Stations Fully Assembled EFS and EDS Factory Sealed Devices Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Methods of Factory Sealing EFS/EDS Series EDS Series Factory sealed EDS and EFS pilot light, pushbutton and selector switch control stations do not need external sealing. Device contacts are factory sealed in explosionproof ESWP contact blocks. Small, compact enclosures have accurately ground wide flanges on both the body and cover for a flame-tight joint. Dimensions (Inches) Bodies EDS factory sealed snap switches or manual motor starting switches do not need external sealing. The switches are enclosed in a unique sealing well with double flanges which mate with the cover and the body. Small, compact enclosures have accurately ground wide flanges on body, cover and sealing well for flame-tight joints. Wiring pigtails are factory sealed from under the sealing well. Reliable pouring of seals at the factory ensures safe sealing. Covers Hub Size /2 Dim. "h" /4 Dim. "i" /6 /4 7 /8 /6 5 /6 Side View General use snap switch front operated and manual motor starting switch Pushbutton switch rocker type side operated Front View - Single gang Front View - Two gang Pushbutton switch front operated Selector switch *See suffix GB in Options section. Dimensions are approximate, not for construction purposes. Surface covers have same length and width as bodies. 526 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Eaton s Crouse-Hinds Business

EDS / EFS Series Control Stations Fully Assembled EDS Factory Sealed Selector Switches Maintained Contact, 600VAC Heavy Duty Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Furnished with pushbuttons, cam actuated by a maintained contact selector mechanism to operate in the sequences shown in the diagrams below. Specify indicating plate markings. See table below listings. Dimensions see page 526 EDS27 Ordering Information - Single Gang Style Position Position 2 Position Replacement Contact Blocks Enclosure with Switch Hub Size Dead End Through Feed Two-Circuit Four-Circuit Two-Circuit Four-Circuit ED ED2 ED ED2 ED2 /2 EDS27 ➀ EDSC27 ➀ /4 EDS227 ➀ EDSC227 ➀ EDS27 ➀ EDSC27 ➀ /2 EDS272 ➀ EDSC272 ➀ /4 EDS2272 ➀ EDSC2272 ➀ EDS272 ➀ EDSC272 ➀ /2 EDS27 ➀ EDSC27 ➀ /4 EDS227 ➀ EDSC227 ➀ EDS27 ➀ EDSC27 ➀ /2 EDS274 ➀ EDSC274 ➀ /4 EDS2274 ➀ EDSC2274 ➀ EDS274 ➀ EDSC274 ➀ /2 EDS275 ➀ EDSC275 ➀ /4 EDS2275 ➀ EDSC2275 ➀ EDS275 ➀ EDSC275 ➀ ➀ If desired, markings on indicating plates may be added to catalog number. Select from the list of standard markings below: Two-Position RUN, JOG FAST, SLOW IN, OUT HAND, AUTOMATIC OPEN, CLOSE RAISE, LOWER FORWARD, REVERSE UP, DOWN START, STOP ON, OFF Three-Position RUN, OFF, JOG, OFF, 2 HAND, OFF, AUTOMATIC OPEN, OFF, CLOSE FORWARD, OFF, REVERSE UP, OFF, DOWN FAST, OFF, SLOW *For Class I, Group B: Consider using EFS series selector switches, see page 54. All enclosures listed above can be modified for Class I, Group B, Div. usage. Add suffix GB to the Cat. No. Seals must be installed within /2" of each conduit opening in Division. These products are suitable for Group B, Div. 2 as listed, without external seals. In Canada, for Group B applications consult factory. For replacement contact blocks, see page 57. Suffixes S64 or S65 may be used on these catalog numbers. See page 525 for explanation of options. www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Eaton s Crouse-Hinds Business 5

EDS / EFS Series Control Stations Fully Assembled EFS Factory Sealed Selector Switches Maintained Contact, 600VAC Heavy Duty Cl. I, Div. & 2, Groups B*, C, D Cl. II, Div., Groups E, F, G NEMA, 7B*CD, 9EFG Furnished with pushbuttons, cam actuated by a maintained contact selector mechanism to operate in the sequences shown in the diagrams below. Specify indicating plate markings. See table below listings. Dimensions see page 526 EFS27 Ordering Information - Single Gang Style Position Position 2 Position Two-Circuit Replacement Contact Blocks ED Enclosure with Switch Hub Size Dead End Through Feed /2 EFS27 ➀ EFSC27 ➀ /4 EFS227 ➀ EFSC227 ➀ EFS27 ➀ EFSC27 ➀ Four-Circuit ED2 /2 EFS272 ➀ EFSC272 ➀ /4 EFS2272 ➀ EFSC2272 ➀ EFS272 ➀ EFSC272 ➀ Two-Circuit ED /2 EFS27 ➀ EFSC27 ➀ /4 EFS227 ➀ EFSC227 ➀ EFS27 ➀ EFSC27 ➀ ED2 /2 EFS274 ➀ EFSC274 ➀ /4 EFS2274 ➀ EFSC2274 ➀ EFS274 ➀ EFSC274 ➀ Four-Circuit ED2 /2 EFS275 ➀ EFSC275 ➀ /4 EFS2275 ➀ EFSC2275 ➀ EFS275 ➀ EFSC275 ➀ ➀If desired, markings on indicating plates may be added to catalog number. Select from the list of standard markings below: Two-Position RUN, JOG FAST, SLOW IN, OUT HAND, AUTOMATIC OPEN, CLOSE RAISE, LOWER FORWARD, REVERSE UP, DOWN START, STOP ON, OFF Three-Position RUN, OFF, JOG, OFF, 2 HAND, OFF, AUTOMATIC OPEN, OFF, CLOSE FORWARD, OFF, REVERSE UP, OFF, DOWN FAST, OFF, SLOW *Class I, Group B: All enclosures listed above are suitable for Class I, Group B, Div. usage. Seals only have to be installed on inch conduit within 5 ft. in Division. For replacement contact blocks, see page 57. Suffixes S64 or S65 may be used on these catalog numbers. See page 525 for explanation of options. 54 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Eaton s Crouse-Hinds Business

EDS / EFS Series Control Stations Sub-assembly Reference Guide For a complete list of components for EDS & EFS Control Stations, see page 54 for FlexStation Series Control Stations and their Sub-assemblies Complete Control Station Sub-assembly Cover & Device Cast Back Box Notes and Requirements PUSHBUTTONS EDS284 DSD98 EDS27 EDSC284 DSD98 EDSC27 EDS25 DSD922 EDS27 Start/ Stop Legend included EDSC25 DSD922 EDSC27 Start/ Stop Legend included EDS290 DSD92 EDS27 EDSC290 DSD92 EDSC27 EDS284-S769-EM-SP DSD98-S769-EM-SP EDS27 Emergency Stop Legend included EDSC284-S769-EM-SP DSD98-S769-EM-SP EDSC27 Emergency Stop Legend included EDS2284 (2) DSD98 EDS272 EDSC2284 (2) DSD98 EDSC272 EDS225 (2) DSD922 EDS272 Start/ Stop Legend included EDSC225 (2) DSD922 EDSC272 Start/ Stop Legend included EDS2290 (2) DSD92 EDS272 EDSC2290 (2) DSD92 EDSC272 PILOT LIGHTS EFS2524-J* DSD948-J* EDS27 EFSC2524-J* DSD948-J* EDSC27 EFS256-J*-J* DSD947-J*-J* EDS27 EFSC256-J*-J* DSD947-J*-J* EDSC27 PUSHBUTTON / PILOT LIGHT COMBINATIONS EDS247-J* DSD958-J* EDS27 * Insert pilot light color EDSC247-J* DSD958-J* EDSC27 * Insert pilot light color EDS2247-J* DSD948-J* & DSD92 EDS272 * Insert pilot light color EDSC2247-J* DSD948-J* & DSD92 EDSC272 * Insert pilot light color EDS22868-J*-J* DSD947-J*-J* & DSD92 EDS272 * Insert pilot light color EDSC22868-J*-J* DSD947-J*-J* & DSD92 EDSC272 * Insert pilot light color SELECTOR SWITCHES EDS227 DSD92 EDS27 EDSC227 DSD92 EDSC27 EDS2272 DSD924 EDS27 EDSC2272 DSD924 EDSC27 EDS227 DSD925 EDS27 EDSC227 DSD925 EDSC27 EDS2274 DSD926 EDS27 EDSC2274 DSD926 EDSC27 EDS2275 DSD927 EDS27 EDSC2275 DSD927 EDSC27 * Insert pilot light color When using the EFS Series pilot light in Cl. I, Div., Group B applications, the EFS back box is required in place of the EDS. MANUAL MOTOR STARTER WITH O/L EDS20 DS45A & SW EDS27 "-W * " for heater, or "-0" distributor provided EDSC20 DS45A & SW EDSC27 "-W * " for heater, or "-0" distributor provided EDS202 DS45A & SW4 EDS27 "-W * " for heater, or "-0" distributor provided EDSC202 DS45A & SW4 EDSC27 "-W * " for heater, or "-0" distributor provided EDS209 DS45A & SW EDS27 "-G * " for heater, or "-0" distributor provided EDSC209 DS45A & SW EDSC27 "-G * " for heater, or "-0" distributor provided EDS2094 DS45A & SW2 EDS27 "-G * " for heater, or "-0" distributor provided EDSC2094 DS45A & SW2 EDSC27 "-G * " for heater, or "-0" distributor provided EDS299 DS45A & SW9 EDS27 "-P * " for heater, or "-0" distributor provided EDSC299 DS45A & SW9 EDSC27 "-P * " for heater, or "-0" distributor provided EDS200 DS45A & SW0 EDS27 "-P * " for heater, or "-0" distributor provided EDSC200 DS45A & SW0 EDSC27 "-P * " for heater, or "-0" distributor provided www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Eaton s Crouse-Hinds Business 59

EDS / EFS Series Control Stations Sub-assembly Reference Guide For a complete list of components for EDS & EFS Control Stations, see page 54 for FlexStation Series Control Stations and their Sub-assemblies Sub-assembly Complete Control Station Cover & Device Cast Back Box Notes and Requirements MANUAL MOTOR STARTER EFD28-T8 DSD96 EDS27 Alternative DS45A & SQ D 250 KO- EDS27 SQ D switch provided by distributor EFDC28-T8 DSD96 EDSC27 Alternative DS45A & SQ D 250 KO- EDSC27 SQ D switch provided by distributor EFD249 DSD97 EDS27 Alternative DS45A & GE 268S EDS27 GE switch provided by distributor EFDC249 DSD97 EDSC27 Alternative DS45A & GE 268S EDSC27 GE switch provided by distributor SNAP SWITCHES EDS229 DS652 & SW5 EDS27 Alternative DSD9 EDS27 External Sealing Fitting Required EDSC229 DS652 & SW5 EDSC27 Alternative DSD9 EDSC27 External Sealing Fitting Required EDS28 DS652 & SW6 EDS27 Alternative DSD64 EDS27 External Sealing Fitting Required EDSC28 DS652 & SW6 EDSC27 Alternative DSD64 EDSC27 External Sealing Fitting Required EDS20 DS652 & SW7 EDS27 Alternative DSD96 EDS27 External Sealing Fitting Required EDSC20 DS652 & SW7 EDSC27 Alternative DSD96 EDSC27 External Sealing Fitting Required EDS240 DS652 & SW8 EDS27 Alternative DSD97 EDS27 External Sealing Fitting Required EDSC240 DS652 & SW8 EDSC27 Alternative DSD97 EDSC27 External Sealing Fitting Required EDS2229 (2) DS652 & (2) SW5 EDS272 Alternative (2) DSD9 EDS272 External Sealing Fitting Required EDSC2229 (2) DS652 & (2) SW5 EDSC272 Alternative (2) DSD9 EDSC272 External Sealing Fitting Required EDSC228 (2) DS652 & (2) SW6 EDSC272 Alternative (2) DSD64 EDSC272 External Sealing Fitting Required EDS220 (2) DS652 & (2) SW7 EDS272 Alternative (2) DSD96 EDS272 External Sealing Fitting Required EDSC220 (2) DS652 & (2) SW7 EDSC272 Alternative (2) DSD96 EDSC272 External Sealing Fitting Required EDSC2240 (2) DS652 & (2) SW8 EDSC272 Alternative (2) DSD97 EDSC272 External Sealing Fitting Required ROCKER SWITCHES EDS2596 DSD949 EDS27 EDSC2596 DSD949 EDSC27 EDS262 DSD95 EDS27 Start/ Stop Legend included EDSC262 DSD95 EDSC27 Start/ Stop Legend included EDS294 DSD950 EDS27 EDSC294 DSD950 EDSC27 EDS2696 (2) DSD949 EDS272 Start/ Stop Legend included EDSC2696 (2) DSD949 EDSC272 Start/ Stop Legend included EDS2262 (2) DSD95 EDS272 EDSC2262 (2) DSD95 EDSC272 EDS2294 (2) DSD950 EDS272 EDSC2294 (2) DSD950 EDSC272 Additional notes: See Eaton's Crouse-Hinds' installation instructions for any possible additional sealing requirements. Part numbers listed with /4" hub in back box (Ex. EDS284). For /2" hub, change the "2" to "" (EDS84). For " hub, change the "2" to "" (EDS84). Control Stations with "Stop" legend have lockout provided as standard. Pilot Light Colors J*-- J= Red, J= Green, J6= Amber, J0= Clear, J= Blue. LED pilot lights are available with LED suffix. Pilot Light Transformers for voltages over 25V. Suffix T2= 240/220-0V, T4= 480/440-0V, T5= 600/500-0V (not available on double pilot cover). Standard legend plate markings are available by adding nomenclature after the part number (EDS284-Run). Selector switch nameplate kits available. 2-Pos = "SS2KIT", -Pos = "SSKIT". See Replacement Parts book for additional information. Copper-free aluminum bodies and covers available with SA suffix. Additional control station options may be found in Section. Group B ratings may be achieved by adding the GB suffix or using the EFS back box. See part number instructions for the item required. Group B ratings may already be achieved when used in Class I, Division 2 applications. See Certifications and Compliances for item required. Additional control station configurations available through the FlexStation Component Series. 540 www.crouse-hinds.com US: -866-764-5454 CAN: -800-265-0502 Copyright 20 Eaton s Crouse-Hinds Business