ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011



Similar documents
ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB i-bus KNX Switch Actuators SA/S Product Information

ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Switch Actuators SA/S

Catalog. Modular DIN rail components Installation contactors

Electronic overload relay EF19 and EF45

ABB i-bus KNX IP Router IPR/S 2.1

Three-phase monitoring relay CM-PFE

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Electronic overload relay EF65, EF96 and EF146

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Technical catalogue. Modular DIN rail components Installation contactors

Product and functional description

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Analog signal converters CC-E I/I Current / current isolators

RM4TG20 three-phase network control relay RM4-T - range V

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Pluggable interface relays CR-P Pcb relays

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

48 SERIES Relay interface modules 10 A

49 Series - Relay interface modules A. Features

PHOENIX CONTACT Features

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

5SV Residual Current Protective Devices

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Safety technique. Emergency stop module BO 5988 safemaster

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

13 SERIES. Electronic step relays A

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

KNX-Flash ABB i-bus KNX

ESB and EN installation contactors Application handbook

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Digital input modules

ABB i-bus KNX i-bus Tool Product Information

Actuator-Sensor-Interface

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

ABB i-bus EIB Logic Module LM/S 1.1

TX OPEN RS232/485 module

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Type: DILM9 10(24VDC) Article No.:

MULTIFUNCTION TIME RELAY CRM-93H

CompactLogix Power Supplies Specifications

Type: DILM32 10(24V50HZ) Article No.:

EIB/KNX IP Interface with Power over Ethernet (PoE)

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Thermistor motor protection

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

38 Series - Relay interface modules A

60 Series - General purpose relays 6-10 A. Features

ABB i-bus EIB / KNX Weather Station WS/S 4.1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Quick Connect. quick - simple - efficient.

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

ABB i-bus KNX DALI-Gateway DG/S 8.1

Power Supplies 3. SDN-P DIN Rail Series

80 Series - Modular timers 16 A. Features

DALI RC BASIC SO. Control unit Operating instructions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

Adjustment functions for both span and shift have been incorporated

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

J TB/TW Temperature limiter, temperature monitor

Electric Rotary Actuator - On/Off or programmable control actuator

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Transcription:

Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are especially suitable for switching resistive loads. The Switch Actuator can be actuated manually using a button. This simultaneously indicates the contact position. SA/S 8.16.2.1 The Switch Actuators can switch up to 12 independent electrical loads via floating contacts. The connection of the outputs is implemented using combo-head screw terminals. Each output is controlled separately via KNX. The device does not require an additional power supply and is ready for immediate use, after the bus voltage has been applied. The Switch Actuators are parameterized via ETS. Connection to KNX is implemented using the bus connection terminal on the front.

Technical data Supply KNX bus voltage 21 31 V Current consumption via bus Power consumption via bus < 12 ma Maximum 250 mw Rated output value SA/S type 2.16.2.1 4.16.2.1 8.16.2.1 12.16.2.1 Current detection no no no no Number (floating contacts 2/group) 2 4 8 12 U n rated voltage 250/440 V AC (50/60 Hz) I n rated current 16 A 16 A 16 A 16 A Leakage loss per device at max. load 2.0 W 4.0 W 8.0 W 12.0 W Output switching current AC3 1) operation (cos ϕ = 0.45) 8 A/230 V AC To DIN EN 60 947-4-1 AC1 1) operation (cos ϕ = 0.8) 16 A/230 V AC To DIN EN 60 947-4-1 Fluorescent lighting load to DIN EN 60 669-1 16 AX/250 V AC (70 mf) 2) Minimum switching capacity 100 ma/12 V AC 100 ma/24 V AC 7 ma/24 V AC DC current switching capacity (resistive load) 16 A/24 V DC Output service life Mechanical service life > 3 x 10 6 Electrical endurance To DIN IEC 60 947-4-1 AC1 1) (240 V/cos ϕ = 0,8) > 10 5 AC3 1) (240 V/cos ϕ = 0,45) > 3 x 10 4 AC5a 1) (240 V/cos ϕ = 0,45) > 3 x 10 4 Output switching times 3) SA/S type 2.16.2.1 4.16.2.1 8.16.2.1 12.16.2.1 Maximum output relay position change per minute if 60 30 15 10 all relays are switched simultaneously. The position changes should be distributed equally within the minute. Maximum output relay position change per minute if 120 120 120 120 only one relay is switched. Connections KNX Via bus connection terminals, 0.8 mm Ø, solid Load current circuits (1 terminal per contact) Universal head screw terminal (PZ 1) 0.2 4 mm 2 fine stranded, 2 x 0.2 2.5 mm 2 0.2 6 mm 2 solid, 2 x 0.2 4 mm 2 Ferrules without/with plastic sleeves 0.25 2.5/4 mm 2 TWIN ferrules 0.5 2.5 mm 2 Contact pin length min. 10 mm Tightening torque max. 0.6 Nm 2 2CDC505051D0205 SA/S x.16.2.1

Operating and display elements Programming button/led For assignment of the physical address Contact position display Relay operator Degree of protection IP 20 To EN 60 529 Protection class II To EN 61 140 Isolation category Overvoltage category III to EN 60 664-1 KNX safety extra low voltage Pollution degree 2 to EN 60 664-1 SELV 24 V DC Temperature range Operation - 5 C +45 C Storage -25 C +55 C Transport -25 C +70 C Ambient conditions Maximum air humidity 95 %, no condensation allowed Design Modular installation device (MDRC) Modular installation device, ProM SA/S type 2.16.2.1 4.16.2.1 8.16.2.1 12.16.2.1 Dimensions 90 x B x 64,5 mm (H x W x D) Width W in mm 36 72 144 216 Mounting width in units (18 mm modules) 2 4 8 12 Mounting depth in mm 64.5 64.5 64.5 64.5 Weight in kg 0.18 0.29 0.51 0.74 Mounting On 35 mm mounting rail To EN 60 715 Mounting position Housing/color as required Plastic housing, gray Approvals KNX to EN 50 090-1, -2 Certification CE mark in accordance with the EMC guideline and low voltage guideline 1) Further information concerning electrical endurance to IEC 60 947-4-1 can be found in the Product Manual at: AC1, AC3, AX, C-load specifications. 2) The maximum inrush current peak may not be exceeded. 3) The specifications apply only after the bus voltage has been applied to the device for at least 30 seconds. Typical relay delay is approx. 20 ms. SA/S x.16.2.1 2CDC505051D0205 3

Lamp output load 16 A Lamps Incandescent lamp load 2,500 W Fluorescent lamps T5/T8 Uncorrected 2,500 W Parallel compensated 1,500 W DUO circuit 1,500 W Low-voltage halogen lamps Inductive transformer 1,200 W Electronic transformer 1,500 W Halogen lamps 230 V 2,500 W Dulux lamp Uncorrected 1,100 W Parallel compensated 1,100 W Mercury-vapor lamp Uncorrected 2,000 W Parallel compensated 2,000 W Switching capacity (switching contact) Maximum peak inrush current I p (150 µs) 400 A Maximum peak inrush current I p (250 µs) 320 A Maximum peak inrush current I p (600 µs) 200 A Number of electronic ballasts (T5/T8, single element) 1) 18 W (ABB EVG 1 x 18 SF) 23 24 W (ABB EVG-T5 1 x 24 CY) 23 36 W (ABB EVG 1 x 36 CF) 14 58 W (ABB EVG 1 x 58 CF) 11 80 W (Helvar EL 1 x 80 SC) 10 1) For multiple element lamps or other types, the number of electronic ballasts must be determined using the peak inrush current of the electronic ballasts, see the Product Manual: Ballast calculation. Device type Application program Maximum number of communication objects Maximum number of group addresses Maximum number of associations SA/S 2.16.2.1 Switch 2f 16A/ * 34 254 254 SA/S 4.16.2.1 Switch 4f 16A/ * 64 254 254 SA/S 8.16.2.1 Switch 8f 16A/ * 124 254 254 SA/S 12.16.2.1 Switch 12f 16A/ * 184 254 254 * = current version number of the application program. Please observe the software information on our homepage for this purpose.. Note For a detailed description of the application program see SA/S Switch Actuators product manual. It is available free-of-charge at www.abb.com/knx. The ETS and the current version of the device application program are required for programming. The current application program can be found with the respective software information for download on the Internet at www.abb.com/knx. After import into ETS it appears in the Catalogs window under Manufacturers/ ABB/Output/Binary output xf 16A/ * (x = 2, 4, 8 or 12). The device does not support the locking function of a KNX device in the ETS. If you inhibit access to all devices of the project with a BCU code, it has no effect on this device. Data can still be read and programmed. 4 2CDC505051D0205 SA/S x.16.2.1

Connection schematic SA/S 12.16.2.1 2CDC072086F0011 1 Label carrier 2 Programming button 3 Programming LED 4 Bus connection terminal 5 Contact position display and manual operation 6 Load current circuits, for every 2 connection terminals Danger Touch voltages. Danger of injury. Observe all-pole disconnection. SA/S x.16.2.1 2CDC505051D0205 5

Dimension drawing SA/S 12.16.2.1 2CDC072019F0013 SA/S 2.16.2.1 SA/S 4.16.2.1 SA/S 8.16.2.1 SA/S 12.16.2.1 Width W 36 mm 72 mm 144 mm 216 mm Mounting width 2 units 4 units 8 units 12 units (18 mm modules) 6 2CDC505051D0205 SA/S x.16.2.1

Notes SA/S x.16.2.1 2CDC505051D0205 7

Contact ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Telefon: +49 (0)6221 701 607 Telefax: +49 (0)6221 701 724 E-Mail: knx.marketing@de.abb.com Further information and local contacts: www.abb.com/knx Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. The agreed properties are definitive for any orders placed. ABB AG shall not be liable for any consequences arising from errors or incomplete information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Reproduction, transfer to third parties or processing of the content including sections thereof is not permitted without prior expressed written permission from ABB AG. Publication number 2CDC505051D0205 (01/2015) Copyright 2015 ABB All rights reserved