Il processo di standardizzazione dell emoglobina A2. Andrea Mosca



Similar documents
The IFCC HbA 2 standardization

Standardization of hemoglobin A 1c : myth or reality? Andrea Mosca

Hb A distribution in cord blood

Certificate of Analysis

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Screening for hemoglobin disorders: Tosoh G7 thalassemia mode

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Intended Use: The kit is designed to detect the 5 different mutations found in Asian population using seven different primers.

for mass spectrometry calibration tools Thermo Scientific Pierce Controls and Standards for Mass Spectrometry

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

POCT in diagnosing and monitoring of Diabetes Mellitus. 13th EFLM Continuous Postgraduate Course, Sverre Sandberg, Noklus / EFLM

The RNAi Consortium (TRC) Broad Institute

A Complete Solution for Method Linearity in HPLC and UHPLC

Gel Filtration Standard

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Symmetry in Diagnostics HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. TOSOH BIOSCIENCE

High-Throughput 3-D Chromatography Through Ion Exchange SPE

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Pep-Miner: A Novel Technology for Mass Spectrometry-Based Proteomics

European Medicines Agency

RNA Extraction and Quantification, Reverse Transcription, and Real-time PCR (q-pcr)

An In-Gel Digestion Protocol

Supporting Information

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

Application Guide... 2

Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study

Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity

Electrospray Ion Trap Mass Spectrometry. Introduction

ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup

FULLY AUTOMATED AND VALIDATED HIGH VOLUME DNA EXTRACTION USING CHEMAGEN MAGNETIC BEADS BASED KITS

THE EFFECT OF α-thalassemia ON CORD BLOOD RED CELL INDICES AND INTERACTION WITH SICKLE CELL GENE

Page finder. 1. Legal Handling Safety warnings and precautions Storage Expiry 4

Standard Mixture. TOF/TOF Calibration Mixture. Calibration Mixture 1 (Cal Mix 1, 1:10) Calibration Mixture 1 (Cal Mix 1, 1:100)

FOR REFERENCE PURPOSES

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Cord Blood Screening for Haemoglobin E (Hb E) Syndrome by Capillary Electrophoresis

Quality. Now Certified to ISO 9001:2008

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Laboration 1. Identifiering av proteiner med Mass Spektrometri. Klinisk Kemisk Diagnostik

How To Use An Acquity Qda Detector

INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE Q5B

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Analytical Test Report

Choose your optimal tools for protein studies

GRS Plasmid Purification Kit Transfection Grade GK (2 MaxiPreps)

Performance and advantages of qnmr measurements

Peptide synthesis, radiolabelling and radiochemical analysis

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

[ Care and Use Manual ]

SpikeTides TM Peptides for relative and absolute quantification in SRM and MRM Assays

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Creatine Kinase Activity Colorimetric Assay Kit ABE assays; Store at -20 C

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

U.S. Patent No. 9,051,563 and other pending patents. Ver

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Protein Separation Technology

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Purification of reaction mixtures using flash chromatography.

Biotechpharma company profile

Creatine Kinase Activity Assay Kit (Colorimetric)

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

Introduction to Proteomics

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Innovative vs Traditional

Appendix 5 Overview of requirements in English

Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution.

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

PRODUCTION AND QUALITY CONTROL OF MEDICINAL PRODUCTS DERIVED BY RECOMBINANT DNA TECHNOLOGY

Nucleic Acid Purity Assessment using A 260 /A 280 Ratios

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

DNA IQ TM Casework Pro Kit for Maxwell 16 A Validation Study

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

Stimuli to the Revision Process

Continuous Chromatography for Monoclonal Antibody Purification from Cell Culture Supernatant

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

Quality Assurance of Vitamins

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Predict Reactivity Note Chicken (100%), Sheep (100%), Rhesus Monkey (100%), Chimpanzee (100%), Bovine (100%), Guinea pig (100%)

Peptide purification strategies

Valentina Gualato, Ph.D. Process Development Scientist

Size Exclusion Chromatography

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

PRINCIPLE. REF (200 tests/cartridge) REF (400 tests/cartridge) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

Supplementary Materials and Methods (Metabolomics analysis)

GENOME RUSSIA PROJECT BLOOD SAMPLES COLLECTION, DNA EXTRACTION AND DNA QUALITY CONTROL PROTOCOLS

Transcription:

Il processo di standardizzazione dell emoglobina A2 Andrea Mosca Centro Interdipartimentale per la Riferibilità Metrologica in Medicina di Laboratorio (CIRME) Dip. di Scienze e Tecnologie Biomediche Università degli Studi di Milano, Milano (Italy) Outline Clinical relevance State-of of-the-art of HbA 2 measurements IFCC HbA 2 standardization Conclusions AM -UniMI 2 1

Clinical relevance 1.7 % of the world s population is carrying thalassemic genes β-thal Mediterranean regions: up to 8 % Middle East: up to 10 % India: 3 15 % Southeast Asia: up to 9 % AM -UniMI 3 Hb A 2 reference intervals (2SD, Tietz) normals: 1.5-3.5 % β-thal trait: 3.7-7.0 % Hb A 2 reference intervals (Menarini HA8160) normals: < 3.2 % borderline: 3.3-3.8 % β-thal trait: >3.8 % AM -UniMI 4 2

Incidence of HbA 2 borderline (between 3.3 and 3.7 %) N = 194 over 8514 (2,3 % ) MCV <80 fl and Hb below the reference interval: 156 over 8514 (1,8 %) AM -UniMI 5 AM -UniMI 6 3

Genotype of 234 (over 1743) subjects with HbA 2 borderline mutation defect 25.6 % no defect 74.4 % NEG/-α3.7 NEG/IVS 1 nt 6 β +δcd 27anti3,7 7 NEG/ααα ααα anti3,7 Hb Variants ** Cap +1570 β prom.. (-101;( -92) 2 20 10 3 1 10 ** 10 β-thal mutations: β 039, IVS I nt 1, IVS I nt 110 ** Hb Variants: Hb Acharnes (cd 53 GCT>ACT); Hb Kokomo (cd 74 GGC>AGC), Hb Ernz (cd 123 ACC>AAC) AM -UniMI 7 State-of of-the-art of HbA 2 measurements EQAS data AM -UniMI 8 4

EQAS So.S.T.E. N = 48 HPLC April-June 2005 AM -UniMI 9 HbA 2, analytical goals (1) - biological variablity - TE = 1.65*CV a +1/4(CV I2 + CV G2 ) 1/2 CV I = 2.8 3.4 % 3.1 % CV G = 20 % TE = 7.6 % CV a = 1.4 1.7 % 1.6 % (goal for imprecision) HbA 2 true value : 3.0 % acceptable measured value: 2.8 3.2 % AM -UniMI 10 5

HbA 2, analytical goals (2) - clinical needs - HbA 2 = 3.3 % (upper normal) HbA 2 = 3.8 % (low β-thal carrier) HbA 2 = 3.55 %? TE = 0.25/3.55 x 100 = 7.0 % AM -UniMI 11 AM -UniMI 12 6

IFCC HbA 2 standardization To prepare a reference material for hemoglobin A 2 in conjunction with IRMM. AM -UniMI 13 IFCC WG-HbA 2 Membership Name Position Country Term Time in Office A. Mosca E. Bissé D. Caruso B. Green A. Van Dorsselaer B. Wild Chair IT 1st Member DE Member IT Corp. Rep. UK Member FR Member UK 2004 01 2006 12 extended AM -UniMI 14 7

IFCC Reference System for HbA 2 Primary reference materials (pure HbA 0 and HbA 2 ) Secondary reference materials (lyophilized) Manufacturer s working calibrator Manufacturer s product calibrator Patient Sample IFCC reference measurement procedure (HPLC-MS) Manufacturer s internal reference measurement procedure Manufacturer s standing measurement procedure Routine measurement procedure IFCC WG-HbA 2 Manufacturer Individual laboratory AM -UniMI 15 Primary Reference Materials Pure HbA 0 and HbA 2 (three batches produced so far) Liquid solutions (buffer with sucrose) at -80 C Available c/o Dept. Science and Biomedical Technology, University of Milano Small aliquots will be transferred to IRMM AM -UniMI 16 8

RBC 3x wash hypotonic lysis whole blood hemolysate Preparation of pure HbA 0 and HbA 2 Sephadex G25 DE-52 CM-52 CM-52 HbA 2 HbA 0 AM -UniMI 17 HbA 0 purified January 2008 (350 mg) HbA 2 purification (under progress) AM -UniMI 18 9

Tests for assessing purity of the primary calibrators HPLC IEF Capillary EF ESI-MS AM -UniMI 19 PolyCATA HPLC analysis (EB) AM -UniMI 20 10

ESI-MS of purified HbA 0 and HbA 2 100 % A21 A20 721.29 757.30 A19 797.11 B21 B20 756.56 794.34 A22 688.55 B22 722.23 A23 658.65 B23 690.88 A18 841.33 A17 890.77 B18 882.49 HbA 0 B17 934.34 A16 946.39 B16 992.68 impurities < 1 % Mw Measured Mw Predicted Alpha 15126,22 15126,38 Beta 15867,15 15867,24 A24 631.26 B24 662.13 616.18 B25 606.08 635.68 685.25 A15 1009.42 B15 1058.79 A14 1081.46 B14 1134.35 A13 1164.54 B13 1221.55 0 100 797.15 HbA 2 % A21 721.30 A22 688.56 A20 757.31 B21 759.30 A18 841.34 A17 B19 890.77 839.12 B18 885.67 B17 937.72 A23 658.68 616.19 A24 631.27 B22 724.84 B23 693.37 A16 946.39 B16 996.26 A15 1009.42 B15 1062.62 A14 1081.44 B14 1138.45 B13 1225.98 0 m/z 575 600 625 650 675 700 725 750 775 800 825 850 875 900 925 950 975 1000 1025 1050 1075 1100 1125 1150 1175 1200 1225 1250 1275 1300 1325 1350 AM -UniMI 21 MS : ESI positive LCT, Micromass Candidate Reference Measurement Procedure for HbA 2 Principle HbA 2 ratio to whole hemoglobin is determined as ratio of a delta chain specific peptide to an alpha chain specific peptide. Peptides are obtained by treating total red blood cell lysate with trypsin. Peptide mixture is analyzed by HPLC-ESI/MS. Calibration is performed against primary calibrators made of mixtures of HbA 2 and HbA 0 primary reference materials. AM -UniMI 22 11

blood erythrocytes hemolysate enzymatic cleavage with trypsin HPLC - Mass spectrometry quantification of specific peptides δt2 (TAVNALWGK) or δt14 (EFTPQMQAAYQK) αt11 (VDPVNFK) Selected peptides Peptide Sequence RT MH+ M2H+ αt11 VDPVNFK 14.02 min 818.4 409.3 δt2 TAVNALWGK 20.19 min 959.5 480.6 δt3 VNVDAVGGEALGR 18.59 min 1256.7 629.1 δt14 EFTPQMQAAYQK 16.56 min 1441.4 721.5 AM -UniMI 24 12

Candidate Reference Measurement Procedure for HbA 2 Optimization 1) The method has been optimized with regard to several steps (digestion conditions, separation of tryptic peptides by RP-HPLC, determination of LOD and QOD, MS tuning, etc.) 2) Two comparison between the results obtained in 2 MS labs has been performed in two steps during 2006 and 2007 3) The SOP has been defined 4) Another laboratory has been involved to reduce the uncertainty AM -UniMI 25 HPLC conditions optimised to separate specific peptides for α and δ chains: HPLC instrument: Agilent 1100 Chemstation,, UV detector (MicroCell( : 1µl) 1 Column : Tosoh TSKgel super ODS 2µm 2 m (2mmx10cm) Gradient : 2% B à 40% B en 76 min Flow : 0.55ml/min (T=40 C) 15µg HbA2 6% Home made MiX 2004-6+2004-7 δt14 δt2 δt5 30µg HbA2 6% AM -UniMI 26 13

2006 exercise 6 calibrators 29 samples 2 digestions, 2 analyses per digestion AM -UniMI 27 2007 exercise 6 calibrators 3 controls 20 samples 2 digestions, 2 analyses per digestion AM -UniMI 28 14

AM -UniMI 29 Secondary Reference Materials Lyophilized hemolysates Process started on May 15, 2007 Previously tested for stability and commutability against 3 HPLC methods Probably available in 2008 AM -UniMI 30 15

AM -UniMI 31 Secondary reference materials for HbA 2 (IRMM) Expression of interest Analis Bio-Rad Laboratories Drew Helena Menarini Sebia Tosoh Pilot lyophilization (100 vials,, 1 level): April 2008 Working Lyophilization (1500 vials,, 2 levels): 2009 IRMM/reference labs activities Homogeneity, stability, commutability Certification AM -UniMI 32 16

IRMM first lyophilization (April 2008) AM -UniMI 33 Further developments Reference method Isotopic dilution More reference labs (4?) Establishing a network (?) Implementation Change of units (mmol/mol Hb) (?) AM -UniMI 34 17

Outcomes + Improvement in genetic counselling + Improvement in analytical performance + Better service to patients and clinicians AM -UniMI 35 References Mosca A. Development of a reference system for HbA 2. EARCR, 15th meeting, Muerten (CH), April 2005. Mosca A, Paleari R, Scimè-Degani V, Leone L, Ivaldi G. Inter-method differences and commutability of control materials for Hb A 2 measurement. Clin Chem Lab Med 2000;38:997-1002. Paleari R, Giambona A, Cannata M, Leto F, Maggio A, Mosca A for the IFCC WG-HbA 2. External Quality Assessment of hemoglobin A 2 measurment: : data from an Italian pilot study with fresh whole blood samples and commercial HPLC systems. Clin Chem Lab Med 2007;45:88-92. IFCC WG-HbA 2. Candidate reference method for HbA 2 based on peptide mapping. Standard Operating Procedure, vs. 2.0,, May 2007. Mosca A, Paleari R, Galanello R, Sollaino C, Perseu L, Demartis FR, Passarello C, Giambona N, Maggio A, for the IFCC WG-HbA 2. New analytical tools and epidemiological data for the identification of HbA 2 borderline subjects in the screening for beta-thalassemia thalassemia. Bioelectrochemistry (in press). AM -UniMI 36 18

Aknowledgments Renata Paleari (Dip. di Sc. Tecnol. Biom., Università degli Studi di Milano) The IFCC Working Group on Standardization of HbA2 Donatella Caruso Christine Schaeffer Amalia Muñoz Pineiro (IRMM, Geel, Belgium) IFCC Scientific Division Renzo Galanello, Carla Sollaino, Franca Rosa Demartis, Lucia Perseu (Università degli Studi, CNR, Cagliari) Cristina Passarello, Nino Giambona, Aurelio Maggio, (A.O. "V. Cervello", Palermo) A. Menarini Diagnostics, Bio-Rad Laboratories, Tosoh Bioscience AM -UniMI 37 19