Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution.

Size: px
Start display at page:

Download "Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution."

Transcription

1 Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution. Introduction: The determination of protein concentration is frequently required in biochemical work. Several methods are available; each having features that suit it to a particular use. We will conduct three different protein assays in this laboratory. There are many reasons to conduct a protein assay. During a purification of a protein, you need to know how pure your sample is by determining the amount of enzymatic activity vs. protein concentration. When comparing samples on an SDS-PAGE gel or using antibody for a western blot, you need to add the same amount of protein form various preparations to the true results. Most protein assays take advantage of a reaction between a reagent dye and the protein of interest that will shift or increase the absorbance of a particular wavelength. Generally the more protein in a sample the higher the absorbance. Protein assay basics: Standard curve: The Bradford and Lowry protein assay lead to a change in absorbance when protein is present. How does this absorbance relate to the actual protein concentration? To know determine the actual concentration of a protein a standard curve is required. A standard curve is a plot of absorbance vs. a varying amount of substance in parallel with unknown protein sample. There are two methods to prepare a standard curve. Absorbance vs. total amount of standard protein, usually in mg or µg of protein. For this style of standard curve, the protein amount in the unknown sample is divided by the volume of sample added to the colormetric reagent. After taking any dilutions into account, the concentration is expressed as mg/ml. A second common method to prepare a standard curve is to prepare a set standards with various known protein concentrations. As long as the volume of the standard samples and the unknown samples are the same the final concentration of the unknown is directly calculated from the least squares line of the standard curve. Of course you still have to correct for any dilution. Don't feel bad if this is confusing, it is for most students and will take several times before you are confident at it. We will get plenty of chances to work on this throughout the semester. Samples should be run in duplicate or triplicate and the averages used for the graph. If the same cuvette or a sipper is used for reading samples, it is a good idea to read those samples with less protein content first to reduce error arising from reagent dye carryover in the cuvette as a result of incomplete rinsing. Depending on the method, proteins generally vary in the reaction with the color dye in the different protein assays. Therefore, it is important to denote what the specific control or reference protein was used to make the standard curve. Two common proteins used for standard curves are bovine serum albumin (BSA) and an immunoglobin (IgG). These two proteins have different amino acid compositions, which leads to a different standard curve and a slight difference in the final determination of the unknown protein concentration. Because the color development is dependent on the amino acid composition of the protein and the presence of a prosthetic group (especially carbohydrate) also influence the protein assay; a purified sample of

2 the protein being assayed or a closely related protein is a preferred standard. Once you have performed the assay a standard curve is generated and the results graphed. Before using the standard curve you ve generated you must be certain that the absorbance is a linear function of concentration which holds within the limits of the Beer- Lambert Law. A = ε c l Abs = extinction coefficient x molar concentration of The sample x pathlength of the cell Beer s law does not hold at high concentrations. A common reason is the depletion of one of the reagents necessary for color production. Thus readings should always be taken in the region where all reagents are in excess (the curve of abs vs. concentration is linear). Sample Preparation: When determining the protein concentration of an unknown sample, several dilutions should be used to ensure the protein concentration is within the range of the assay. Usually 10 fold dilutions are used to get the unknowns within the standard curve range. While this may seem redundant and a pain in the neck (or other body parts), often times your sample may be too diluted to fit within the standard curve. Without the additional dilutions, you will have to start over again. Don t forget that all dilutions must be taken into account in calculating the final concentration of the protein. Finally, with every assay a blank must be included. The blank or the tube without a standard protein is usually made up in the same buffer as in the samples. This way if the buffer has an effect on the protein assay reagent, each sample (and the blank) will have been altered the same. The blank is used to set the instrument to the 100% transmittance or 0 absorbance. When assaying protein, it is important that the volume is the same for each tube. Protein is generally added first, followed by enough buffer to bring each tube to the same volume. The tubes are mixed well after each addition. The color-producing reagent is always added last, and the reaction may need to be timed accurately. Experiment In this experiment you will be provided with a protein standard (BSA) at a known concentration (1.5 mg/ml) and an unknown sample containing protein at unknown concentration. Your objective will be to measure protein concentration by the Bradford, Lowry and Warburg-Christain methods. Compare your results with each technique and compare the different types of assays and become familiar with each technique. The first step in the analysis is to prepare dilutions of the BSA standard and to construct a standard curve for parts 2 and 3. To determine the apparent protein concentration in the unknowns, you will need to examine several dilutions. It is a good experimental design to perform the standards and the unknowns side by side and at the same time. This ensures that variables such as temperature, time, batches of reagents, etc., are internally controlled. You also should perform the assays in duplicate. This way large pipetting errors may be easily recognized and mental error ascertained. For parts 2 and 3 it will be very helpful to set up a table of volumes to add in advance. The table in the handout is only an example and is not sufficient for the whole experiment. Don t forget that this table and all calculations will be in the lab book. Also be certain to include an outline of the procedures in you lab book prior to lab.

3 Part 1) Warburg-Christain Method The concentration of protein can be estimated by measuring the absorbance of protein at 280 and 260 nm. Be careful that a quartz cuvette is used, glass and plastic cuvettes will not transmit about 300 nm and smaller. Most proteins have an absorbance maximum at 280 nm, owing to the presence of tyrosine, tryptophan and phenylalanine. The benefits of this method are that the sample is not destroyed and can be used for other experiments. The disadvantage is the large volume of sample required to fill the cuvette and it is less sensitive. Since the amino acid composition varies greatly between proteins, the molar absorptivity will change. Proteins that have a low aromatic amino acid content will have low or no absorbance at 280 nm. Nucleic acids often are found to be a contaminant in many protein preparations. The nucleic acids will absorb maximally at 260 nm and have a large absorbance at 280 nm. The absorbance of nucleic acids is about 10 times greater than the same concentration of a protein at 280 nm. To correct for this Warburg and Christian developed a method to adjust for interference by nucleic acids. Mixtures of pure protein and pure nucleic acids were used to come up with a correction factor for the absorbencies at 280 and 260 nm. To determine the concentration of your protein use the correction factor shown below: Protein (mg/ml) = 1.55 A A260 Procedure. 1. Prepare a 0.75 ml 1:4 dilution of your unknown protein. 2. Determine the absorbance of the protein at both 280 and 260 nm 3. Use the equation above to determine the concentration of the protein in your solution. Part 2) The Lowry method The Lowry method is one of the most sensitive and widely used. The Lowry procedure can detect protein levels as low as 5 µg. There are several limitations to this method. Several contaminants interfere with the assay. Most commonly: some buffers, ammonium sulfate (>0.15%) glycine and reducing agents such as dithiothreitol (DTT) or ß mercaptoethanol. The principle behind color development is an improvement on another method called the Biuret method. In alkaline conditions, copper (II) is thought to bind to the peptide nitrogen of proteins. This complex absorbs light maximally at 550 nm. This reaction is followed by the reduction under alkaline conditions of the Folin-Ciocalteu reagent. The Folin-Ciocalteu reagent is a dark blue-reduced molybdotungstates, which are reduced by tyrosine, tryprophan and polar amino acid. Materials Stock reagents Solution A: 1% w/v copper sulfate (CuSO4.5H2O) Solution B: 2% w/v Na/K tartrate Solution C: 0.2 M NaOH Solution D 4% Na carbonate Lowry reagent I: Add 24.5 ml of solution D to 24.5 ml of solution C. Then add 0.5 ml of solution A and 1 ml of solution B. This is the copper-alkali reagent (Lowry reagent I), which must be freshly prepared for each lab session Lowry Reagent II: Dilute the Folin-Ciocalteu reagent 1:2 with H2O (make 3.0 mls)

4 Procedure: 1. Prepare Lowery reagent I and II 2. In duplicate, prepare the standard curve using up to 6 points including the zero tube. Use small sized test tubes. The final volume of each sample will be ml and the protein range from 0 to 250 µg of standard. Start with the stock standard BSA and create a set of dilutions using serial dilutions. How many is up to you, BUT thing about how the points will line up on the graph. Include a ZERO (a tube without any protein). 3. Prepare at least two dilutions of your unknown standard. Include a non-diluted sample. Prepare each in duplicate. 4. Prepare one additional sample (water, like the zero tube) to blank the spectrophotometer with. 5. Add 1.25 ml of Lowry reagent I to each sample. 6. Mix well and let stand at room temperature for 10 min. 7. Add ml of Lowry reagent II 8. Immediately vortex and incubate at room temperature for 30 min. 9. Zero the spectrophotometer against a blank consisting of ml of water as descrbed in step Measure absorbance at 750 nm and record in your lab book. A sample table to help you prepare your standards for the lowery protein assay is shown below: Tube # Reagent BSA (µl) H2O (µl) Unknown (µl) Lowery Reagent I (ml) Lowery Reagent II (ml) Part 3) Dye-binding method (Bradford) The binding of the dye, Coomassie Brilliant Blue G-250, to proteins causes a shift in the absorbance maximum of the dye from 465 nm to 595 nm in acidic conditions. This method has several advantages over other methods and is about as sensitive as the Lowry method. Unlike the Lowry method there are few interfering substances, the only known compounds are high concentrations of the detergents triton x-100 and sodium dodecyl sulfate (SDS). This assay is quick and results observed immediately. The color is developed when the dye forms a strong, noncovalent complexes with proteins by electrostatic interactions with amino and carboxyl groups and via Van der Waals forces. There is a great deal of batch to batch variation for this assay so it is imperative to run a standard curve with each assay.

5 Materials 1X BioRad Dye reagent, BSA protein standard, microfuge tubes. Procedure: 1. In duplicate, prepare a standard solutions of at least 6 tubes, each with an increasing mass of protein. Use CV=CV to determine how much water and how much stock BSA solution to use in each tube. Use the microfuge tubes. Each sample should be 50 µl in volume after water and BSA have been added. Ignore the Bradford reagent, that comes later. The mass of the protein should range from 0 to 75 µg. 2. Prepare two or three dilutions of your unknown. Also assay a nondiluted sample. 3. Prepare a blank sample using 50 µl of water. 4. Add 1.5 ml of Bradford dye to each sample. 5. Vortex and incubate at room temperature for 5 min 6. Read the absorbance at 595 nm against the blank prepared in step 3. A sample table for the Bradford protein assay is shown below: Tube # Reagent BSA (µl) H2O (µl) Unknown (µl) Bradford Reagent I (ml) Calculations: For both the Lowery and Bradford Assays - 1) Determine the mass of protein (mg) in each tube of your standard curve. 2) Average the readings for each standard. You can not conduct a standard deviation on an n=2. 3) Graph the absorbance of the standards vs. the mass of protein in each standard tube. Refer to last week s handout for determining which variable goes on which axis. The unknown absorbance can not be graphed. 4) Use a least squares line also known as a linear regression. Include the R 2 value in your graph. 5) Use the equation for the linear regression to calculate the mass of protein in your unknown. Don t forget to take into account any dilutions of the unknown. 6) Divide the mass of protein by the volume of sample of unknown you added to the test tube. 7) Report the answer in concentration (mg/ml for proteins). Lab Report: This will be a simple report. The grade will depend on: the completeness of the information requested below the calculations, observations recorded in the lab book the standard curves and the accuracy protein determinations of your unknowns.

6 Turn in your lab books with the following information. Tape graphs into the lab book. 1. Make certain the title and purpose is in the lab book. 2. Include the experiment in the table of contents 3. Include an outline of the procedures and reference the handout. 4. Include the table of additions for each of the three methods. Do this ahead of time. 5. Simply record the results for each section and prepare a graph of the standard curve for part 2 and Calculate the concentrations of your unknown (don t forget to indicate which unknown you used). The answer must be in mg/ml. 7. Finally in one very brief section discuss the differences between all three methods, any variations in the concentration of the unknown as determined by each method and your personal preferences for conducting this assay if you had a very small sample that you worked for 1 month to get.

RNA) - - - = 1 1 = 1 EU

RNA) - - - = 1 1 = 1 EU Colorimetric Methods for Determining Protein Concentration. Goals: 1. Learn how to use colorimetric (Lowry, BCA, and Bradford) methods to determine protein concentration in mg/ml. 2. Use intrinsic biomolecular

More information

PROTEINS (LOWRY) PROTOCOL

PROTEINS (LOWRY) PROTOCOL 1 PROTEINS (LOWRY) PROTOCOL 1. INTRODUCTION The Lowry Assay: Protein by Folin Reaction (Lowry et al., 1951) has been the most widely used method to estimate the amount of proteins (already in solution

More information

Colorimetry Extinction coefficient (ε) Lambda max (λ max ) Qualitative vs. quantitative analysis

Colorimetry Extinction coefficient (ε) Lambda max (λ max ) Qualitative vs. quantitative analysis Lab Week 2 - Spectrophotometry Purpose: Introduce students to the use of spectrophotometry for qualitative (what is it) and quantitative (how much is there of it) analysis of biological samples and molecules.

More information

TOTAL PROTEIN FIBRINOGEN

TOTAL PROTEIN FIBRINOGEN UNIT: Proteins 16tproteins.wpd Task Determination of Total Protein, Albumin and Globulins Objectives Upon completion of this exercise, the student will be able to: 1. Explain the ratio of albumin and globulin

More information

TECHNICAL BULLETIN. Bicinchoninic Acid Protein Assay Kit. Catalog Numbers BCA1 AND B9643

TECHNICAL BULLETIN. Bicinchoninic Acid Protein Assay Kit. Catalog Numbers BCA1 AND B9643 Bicinchoninic Acid Protein Assay Kit Catalog Numbers BCA1 AND B9643 TECHNICAL BULLETIN Synonym: BCA Product Description Protein determination is one of the most common operations performed in biochemical

More information

Calculating Nucleic Acid or Protein Concentration Using the GloMax Multi+ Microplate Instrument

Calculating Nucleic Acid or Protein Concentration Using the GloMax Multi+ Microplate Instrument Calculating Nucleic Acid or Protein Concentration Using the GloMax Multi+ Microplate Instrument Technical Note INTRODUCTION Direct measurements of nucleic acid samples at OD 260 or protein samples at OD

More information

Nucleic Acid Purity Assessment using A 260 /A 280 Ratios

Nucleic Acid Purity Assessment using A 260 /A 280 Ratios Nucleic Acid Purity Assessment using A 260 /A 280 Ratios A common practice in molecular biology is to perform a quick assessment of the purity of nucleic acid samples by determining the ratio of spectrophotometric

More information

2 Spectrophotometry and the Analysis of Riboflavin

2 Spectrophotometry and the Analysis of Riboflavin 2 Spectrophotometry and the Analysis of Riboflavin Objectives: A) To become familiar with operating the Platereader; B) to learn how to use the Platereader in determining the absorption spectrum of a compound

More information

10/5/06 Lab 3. Protein Determination. Lab 3. PROTEIN DETERMINATION

10/5/06 Lab 3. Protein Determination. Lab 3. PROTEIN DETERMINATION 10/5/06 Lab 3. Protein Determination Lab 3. PROTEIN DETERMINATION I. INTRODUCTION Reading in Biology, 6 th ed. By Campbell: PROTEINS-MANY STRUCTURES, MANY FUNCTIONS p. 71-80 Blood is a connective tissue

More information

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline EXPERIMENT 5 Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline UNKNOWN Submit a clean, labeled 100-mL volumetric flask to the instructor so that your unknown iron solution

More information

Measuring Protein Concentration through Absorption Spectrophotometry

Measuring Protein Concentration through Absorption Spectrophotometry Measuring Protein Concentration through Absorption Spectrophotometry In this lab exercise you will learn how to homogenize a tissue to extract the protein, and then how to use a protein assay reagent to

More information

Determination of the Sensitivity Range of Biuret Test for Undergraduate Biochemistry Experiments

Determination of the Sensitivity Range of Biuret Test for Undergraduate Biochemistry Experiments 77 Determination of the Sensitivity Range of Biuret Test for Undergraduate Biochemistry Experiments Gerardo Janairo * ; Marianne Linley Sy; Leonisa Yap; Nancy Llanos-Lazaro; Julita Robles Chemistry Department

More information

Quick Start Bradford Protein Assay

Quick Start Bradford Protein Assay Quick Start Bradford Protein Assay Instruction Manual For technical service call your local Bio-Rad office, or in the US, 1-800-4BIORAD (1-800-424-6723) Table of Contents Section 1 Introduction 1 1.1 Principle

More information

Austin Peay State University Department of Chemistry Chem 1111. The Use of the Spectrophotometer and Beer's Law

Austin Peay State University Department of Chemistry Chem 1111. The Use of the Spectrophotometer and Beer's Law Purpose To become familiar with using a spectrophotometer and gain an understanding of Beer s law and it s relationship to solution concentration. Introduction Scientists use many methods to determine

More information

Using the Spectrophotometer

Using the Spectrophotometer Using the Spectrophotometer Introduction In this exercise, you will learn the basic principals of spectrophotometry and and serial dilution and their practical application. You will need these skills to

More information

Enzymes: Amylase Activity in Starch-degrading Soil Isolates

Enzymes: Amylase Activity in Starch-degrading Soil Isolates Enzymes: Amylase Activity in Starch-degrading Soil Isolates Introduction This week you will continue our theme of industrial microbiologist by characterizing the enzyme activity we selected for (starch

More information

6 Characterization of Casein and Bovine Serum Albumin

6 Characterization of Casein and Bovine Serum Albumin 6 Characterization of Casein and Bovine Serum Albumin (BSA) Objectives: A) To separate a mixture of casein and bovine serum albumin B) to characterize these proteins based on their solubilities as a function

More information

Protein quantification and detection methods

Protein quantification and detection methods Protein quantification and detection methods 1) Spectroscopic procedures 2) Measurement of the total protein content by colorimetry 3) Amino acid analysis 4) Other methods, eg. radiolabelling of proteins,

More information

ENZYME KINETICS ENZYME-SUBSTRATE PRODUCTS

ENZYME KINETICS ENZYME-SUBSTRATE PRODUCTS ENZYME KINETICS INTRODUCTION The study of reaction rates catalyzed by enzymes and the factors affecting them is generally referred to as enzyme kinetics. The basic components of an enzyme catalyzed reaction

More information

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions. EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions. Outcomes After completing this experiment, the student should be able to: 1. Prepare

More information

Western Blotting: Mini-gels

Western Blotting: Mini-gels Western Blotting: Mini-gels Materials a Protein Extraction Buffer (for callus or kernel), Solution Stock Final Volume Tris-HCl ph 80 1 M 200 mm 20 ml NaCl 4 M 100 mm 25 ml Sucrose 2 M 400 mm 20 ml EDTA

More information

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives. 1 Lab 2 Biochemistry Learning Objectives The lab has the following learning objectives. Investigate the role of double bonding in fatty acids, through models. Developing a calibration curve for a Benedict

More information

Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry

Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry General Medicine Jiřina Crkovská (translated by Jan Pláteník) 2010/2011 1 Spectrophotometry is one of the most widely used instrumental

More information

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1 Experiment 13H FV 1/25/2011(2-run) THE REACTION OF RED FOOD COLOR WITH BLEACH 1 PROBLEM: Determine the rate law for the chemical reaction between FD&C Red Dye #3 and sodium hypochlorite. LEARNING OBJECTIVES:

More information

Chem 131A: Absorbance of Riboflavin

Chem 131A: Absorbance of Riboflavin Chem 131A: Absorbance of Riboflavin Purpose: The purpose of this experiment is to: 1) Familiarize the student with the use of the HP 8452 diode array spectrophotometer, 2) examine the limitations of the

More information

A Beer s Law Experiment

A Beer s Law Experiment A Beer s Law Experiment Introduction There are many ways to determine concentrations of a substance in solution. So far, the only experiences you may have are acid-base titrations or possibly determining

More information

Covalent Conjugation to Cytodiagnostics Carboxylated Gold Nanoparticles Tech Note #105

Covalent Conjugation to Cytodiagnostics Carboxylated Gold Nanoparticles Tech Note #105 Covalent Conjugation to Cytodiagnostics Carboxylated Gold Nanoparticles Tech Note #105 Background Gold nanoparticle conjugates have been widely used in biological research and biosensing applications.

More information

COLORIMETER. Description 0358BT. Figure 1. The Colorimeter

COLORIMETER. Description 0358BT. Figure 1. The Colorimeter COLORIMETER Description 0358BT Figure 1. The Colorimeter Introduction The Colorimeter is designed to determine the concentration of a solution by analyzing its color intensity. Monochromatic light from

More information

Laboratory 5: Properties of Enzymes

Laboratory 5: Properties of Enzymes Laboratory 5: Properties of Enzymes Technical Objectives 1. Accurately measure and transfer solutions with pipettes 2. Use a Spectrophotometer to study enzyme action. 3. Properly graph a set of data. Knowledge

More information

Quantitation of Peptides and Amino Acids with a Synergy HT using UV Fluorescence

Quantitation of Peptides and Amino Acids with a Synergy HT using UV Fluorescence Quantitation of Peptides and Amino Acids with a Synergy HT using UV Fluorescence Introduction Eukaryotic and prokaryotic cells contain a number of compounds that are fluorescent with UV light excitation.

More information

Upon completion of this lab, the student will be able to:

Upon completion of this lab, the student will be able to: 1 Learning Outcomes EXPERIMENT B4: CHEMICAL EQUILIBRIUM Upon completion of this lab, the student will be able to: 1) Analyze the absorbance spectrum of a sample. 2) Calculate the equilibrium constant for

More information

Biology 309 Lab Notebook

Biology 309 Lab Notebook Name: Biology 309 Lab Notebook This is a guided lab notebook for you to keep well-organized notes about procedures and record experimental data for experiments as they are performed. It is guided because,

More information

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40 Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40 Note: there is a second document that goes with this one! 2046 - Absorbance Spectrophotometry - Calibration Curve Procedure. The second document

More information

Reaction Stoichiometry and the Formation of a Metal Ion Complex

Reaction Stoichiometry and the Formation of a Metal Ion Complex Reaction Stoichiometry and the Formation of a Metal Ion Complex Objectives The objectives of this laboratory are as follows: To use the method of continuous variation to determine the reaction stoichiometry

More information

Running protein gels and detection of proteins

Running protein gels and detection of proteins Running protein gels and detection of proteins 1. Protein concentration determination using the BIO RAD reagent This assay uses a colour change reaction to give a direct measurement of protein concentration.

More information

Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus

Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus Introduction Protein extraction from tissues and cultured cells is the first step for many biochemical and analytical

More information

Quaternary Ammonium Compounds DOC316.53.01128

Quaternary Ammonium Compounds DOC316.53.01128 Quaternary Ammonium Compounds DOC316.53.01128 Direct Binary Complex Method Method 8337 0.2 to 5.0 mg/l as CTAB (cetyl-trimethylammonium bromide) Powder Pillows Scope and application: For cooling tower

More information

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy 2-1 Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy Introduction: The kinetics of a decomposition reaction involving hydroxide ion and crystal violet, an organic dye used

More information

Malachite Green Phosphate Assay Kit

Malachite Green Phosphate Assay Kit Malachite Green Phosphate Kit Item No. 10009325 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 4 Precautions

More information

Catalase Assay Kit. Catalog Number CAT100 Storage Temperature 2 8 C TECHNICAL BULLETIN

Catalase Assay Kit. Catalog Number CAT100 Storage Temperature 2 8 C TECHNICAL BULLETIN Catalase Assay Kit Catalog Number CAT100 Storage Temperature 2 8 C TECHNICAL BULLETIN Product Description Catalase is an antioxidant enzyme ubiquitously present in mammalian and non-mammalian aerobic cells

More information

Lab 2. Spectrophotometric Measurement of Glucose

Lab 2. Spectrophotometric Measurement of Glucose Lab 2 Spectrophotometric Measurement of Glucose Objectives 1. Learn how to use a spectrophotometer. 2. Produce a glucose standard curve. 3. Perform a glucose assay. Safety Precautions Glucose Color Reagent

More information

Lab 5: Quantitative Analysis- Phosphates in Water By: A Generous Student. LBS 171L Section 9 TA: Dana October 27, 2005

Lab 5: Quantitative Analysis- Phosphates in Water By: A Generous Student. LBS 171L Section 9 TA: Dana October 27, 2005 How uch Phosphate is the Body Being Exposed to During a Lifetime by Showering? Lab 5: Quantitative Analysis- Phosphates in Water By: A Generous Student LBS 171L Section 9 TA: Dana October 7, 005 [Note:

More information

Factors Affecting Enzyme Activity

Factors Affecting Enzyme Activity INTRODUCTION Factors Affecting Enzyme Activity The chemical reactions occurring in living things are controlled by enzymes. An enzyme is a protein in the cell which lowers the activation energy of a catalyzed

More information

Phenolphthalein-NaOH Kinetics

Phenolphthalein-NaOH Kinetics Phenolphthalein-NaOH Kinetics Phenolphthalein is one of the most common acid-base indicators used to determine the end point in acid-base titrations. It is also the active ingredient in some laxatives.

More information

Lab #11: Determination of a Chemical Equilibrium Constant

Lab #11: Determination of a Chemical Equilibrium Constant Lab #11: Determination of a Chemical Equilibrium Constant Objectives: 1. Determine the equilibrium constant of the formation of the thiocyanatoiron (III) ions. 2. Understand the application of using a

More information

Chemistry 118 Laboratory University of Massachusetts Boston Beer s Law

Chemistry 118 Laboratory University of Massachusetts Boston Beer s Law Name: LEARNING GOALS: Chemistry 118 Laboratory University of Massachusetts Boston Beer s Law 1. Become familiar with the concept of concentration and molarity. 2. Become familiar with making dilutions

More information

HiPer Ion Exchange Chromatography Teaching Kit

HiPer Ion Exchange Chromatography Teaching Kit HiPer Ion Exchange Chromatography Teaching Kit Product Code: HTC001 Number of experiments that can be performed: 5 Duration of Experiment: Protocol: 5-6 hours Storage Instructions: The kit is stable for

More information

How to Biotinylate with Reproducible Results

How to Biotinylate with Reproducible Results How to Biotinylate with Reproducible Results Introduction The Biotin Streptavidin system continues to be used in many protein based biological research applications including; ELISAs, immunoprecipitation,

More information

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS 1 ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS Buck Scientific Atomic Absorption Spectrophotometer, Model 200 Atomic absorption spectroscopy (AAS) has for many years

More information

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1 Chemistry 111 Lab: Intro to Spectrophotometry Page E-1 SPECTROPHOTOMETRY Absorption Measurements & their Application to Quantitative Analysis study of the interaction of light (or other electromagnetic

More information

LAB TOPIC 4: ENZYMES. Enzyme catalyzed reactions can be expressed in the following way:

LAB TOPIC 4: ENZYMES. Enzyme catalyzed reactions can be expressed in the following way: LAB TOPIC 4: ENZYMES Objectives Define enzyme and describe the activity of enzymes in cells. Discuss the effects of varying enzyme concentrations on the rate of enzyme activity. Discuss the effects of

More information

2.02 DETERMINATION OF THE FORMULA OF A COMPLEX BY SPECTROPHOTOMETRY

2.02 DETERMINATION OF THE FORMULA OF A COMPLEX BY SPECTROPHOTOMETRY 2nd/3rd Year Physical Chemistry Practical Course, Oxford University 2.02 DETERMINATION OF THE FORMULA OF A COMPLEX BY SPECTROPHOTOMETRY (4 points) Outline Spectrometry is widely used to monitor the progress

More information

QuickZyme Soluble Collagen Assay

QuickZyme Soluble Collagen Assay QuickZyme Soluble Collagen Assay Version June 2012 FOR RESEARCH USE ONLY NOT FOR USE IN DIAGNOSTIC PROCEDURES This package insert must be read in its entirety before using this product. Introduction Collagen

More information

2C: One in a Million. Part 1: Making solutions. Name: Section: Date: Materials

2C: One in a Million. Part 1: Making solutions. Name: Section: Date: Materials Name: Section: Date: 2C: One in a Million Drinking water can contain up to 1.3 parts per million (ppm) of copper and still be considered safe. What does parts per million mean? Both living things and the

More information

Determination of the Mass Percentage of Copper in a Penny. Introduction

Determination of the Mass Percentage of Copper in a Penny. Introduction Determination of the Mass Percentage of Copper in a Penny Introduction This experiment will cost you one penny ($0.01). The penny must be minted after 1983. Any penny will do; for best results the penny

More information

ab185915 Protein Sumoylation Assay Ultra Kit

ab185915 Protein Sumoylation Assay Ultra Kit ab185915 Protein Sumoylation Assay Ultra Kit Instructions for Use For the measuring in vivo protein sumoylation in various samples This product is for research use only and is not intended for diagnostic

More information

PHENOLIC AND ANTIOXIDANT ASSAYS. Gaziosmanpaşa University

PHENOLIC AND ANTIOXIDANT ASSAYS. Gaziosmanpaşa University PHENOLIC AND ANTIOXIDANT ASSAYS Dr. Ayşe ÖZBEY Gaziosmanpaşa University A number of spectrophotometric methods for quantification of phenolic compounds in plant materials have been developed. Based on

More information

Spectrophotometric Method for the Determination of Paracetamol

Spectrophotometric Method for the Determination of Paracetamol Spectrophotometric Method for the Determination of Paracetamol Buddha Ratna Shrestha * and Raja Ram Pradhananga Central Department of Chemistry, Tribhuvan University, Kirtipur, Nepal *Department of Metallurgy

More information

Qualification Study CHO 360-HCP ELISA (Type A to D)

Qualification Study CHO 360-HCP ELISA (Type A to D) Short Report Qualification Study CHO 360-HCP ELISA (Type A to D) Presented by: http://www.biogenes.de Version 01 Issue date: 27.11.2013 Version 01 Page 1 of 8 Table of Content TABLE OF CONTENT... 2 1 INTRODUCTION...

More information

Human Free Testosterone(F-TESTO) ELISA Kit

Human Free Testosterone(F-TESTO) ELISA Kit Human Free Testosterone(F-TESTO) ELISA Kit Catalog Number. MBS700040 For the quantitative determination of human free testosterone(f-testo) concentrations in serum, plasma. This package insert must be

More information

Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer. NAME: Lab Section: Date: Sign-Off:

Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer. NAME: Lab Section: Date: Sign-Off: Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer NAME: Lab Section: Date: Sign-Off: Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer Introduction Weak acids,

More information

Phosphorus, Reactive (Orthophosphate)

Phosphorus, Reactive (Orthophosphate) Phosphorus, Reactive (Orthophosphate) DOC316.53.01113 Amino Acid Method 1 Method 8178 0.23 to 30.00 mg/l PO 4 Reagent Solution Scope and application: For water, wastewater and seawater. 1 Adapted from

More information

MTT Cell Proliferation Assay

MTT Cell Proliferation Assay ATCC 30-1010K Store at 4 C This product is intended for laboratory research purposes only. It is not intended for use in humans, animals or for diagnostics. Introduction Measurement of cell viability and

More information

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8) Selenium Determination, Page 1 KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY I. BACKGROUND. (VERSION 1.8) The majority of reactions used in analytical chemistry possess the following characteristics:

More information

Reaction of Blue Food Dye with Bleach

Reaction of Blue Food Dye with Bleach Exercise 2 Reaction of Blue Food Dye with Bleach 2 Introduction In the experiment, you will study the rate of the reaction of FD&C Blue #1 (Blue #1 is denoted by E number E133 in food stuff) with sodium

More information

NITRIC OXIDE and NITROGEN DIOXIDE 6014

NITRIC OXIDE and NITROGEN DIOXIDE 6014 NITRIC OXIDE and NITROGEN DIOXIDE 6014 NO MW: 30.01 CAS: 10102-43-9 RTECS: QX0525000 46.01 10102-44-0 QW9800000 METHOD: 6014, Issue 1 EVALUATION: FULL Issue 1: 15 August 1994 OSHA : 25 ppm NO; C 1 ppm

More information

TECHNICAL BULLETIN. FluoroTag FITC Conjugation Kit. Product Number FITC1 Storage Temperature 2 8 C

TECHNICAL BULLETIN. FluoroTag FITC Conjugation Kit. Product Number FITC1 Storage Temperature 2 8 C FluoroTag FITC Conjugation Kit Product Number FITC1 Storage Temperature 2 8 C TECHNICAL BULLETIN Product Description The FluoroTag FITC Conjugation Kit is suitable for the conjugation of polyclonal and

More information

Protein Precipitation Protocols

Protein Precipitation Protocols Protein Precipitation Protocols Notes: All reagents need to high purity/hplc quality. All tubes used should be new or hand cleaned thoroughly with Micro90 detergent. High quality water needs to be used

More information

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA KAMIYA BIOMEDICAL COMPANY Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA For the quantitative determination of mouse CKMB in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-57681

More information

An In-Gel Digestion Protocol

An In-Gel Digestion Protocol An In-Gel Digestion Protocol This protocol describes the digestion of a protein present in an SDS-PAGE gel band with trypsin. The band can be taken from either a 1D or 2D electrophoresis gel. Reagents

More information

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit Catalog Number. CSB-E14405r For the quantitative determination of rat creatine kinase MM isoenzyme (CK-MM) concentrations in serum, plasma and tissue

More information

TOTAL SULPHITE (SO 2 )

TOTAL SULPHITE (SO 2 ) www.megazyme.com TOTAL SULPHITE (SO 2 ) (Enzymatic) ASSAY PROCEDURE K-ETSULPH 02/15 (50 Assays per Kit) or (588 Auto-Analyser Assays per Kit) or (500 Microplate Assays per Kit) Megazyme International Ireland

More information

Stage 1 Desired Results

Stage 1 Desired Results Lesson Title: Phosphate Testing Contract Discipline Focus: Chemistry Grade level: 11-12 Length of lesson: 1.5 class periods Content Standard(s): Stage 1 Desired Results Understanding (s)/goals Students

More information

BY UV SPECTROPHOTOMETRY

BY UV SPECTROPHOTOMETRY 1 of 9 1. PURPOSE This Standard Operating Procedure describes the method for measuring the concentration of viral particles using UV/Vis spectrophotometry at 260 and 280 nm. 2. SCOPE This procedure is

More information

Experiment 7 (Lab Period 8) Quantitative Determination of Phosphatase Activity

Experiment 7 (Lab Period 8) Quantitative Determination of Phosphatase Activity Experiment 7 (Lab Period 8) Quantitative Determination of Phosphatase Activity Phosphatases are enzymes that catalyze the hydrolysis of organic-phosphate compounds, releasing inorganic phosphate from the

More information

Protein transfer from SDS-PAGE to nitrocellulose membrane using the Trans-Blot SD cell (Western).

Protein transfer from SDS-PAGE to nitrocellulose membrane using the Trans-Blot SD cell (Western). Western Blot SOP Protein transfer from SDS-PAGE to nitrocellulose membrane using the Trans-Blot SD cell (Western). Date: 8/16/05, 10/31/05, 2/6/06 Author: N.Oganesyan, R. Kim Edited by: R. Kim Summary:

More information

CHRISTIAN LAB WESTERN BLOT PROTOCOL

CHRISTIAN LAB WESTERN BLOT PROTOCOL CHRISTIAN LAB WESTERN BLOT PROTOCOL There is actually 2 parts to a western blot: A. SDS-PAGE: Separates protein by size. Smaller proteins migrate faster through the gel than larger proteins. Size separation

More information

PRACTICAL 3: DIGESTIVE ENZYMES, SPECIFICITY AND ph

PRACTICAL 3: DIGESTIVE ENZYMES, SPECIFICITY AND ph PRACTICAL 3: DIGESTIVE ENZYMES, SPECIFICITY AND ph 3.1 Introduction The aims of this practical are: to illustrate the different ph dependence of gastric and pancreatic digestive proteases to illustrate

More information

protein assays tech Colorimetric Protein Assays

protein assays tech Colorimetric Protein Assays protein assays tech note 1069 Colorimetric Protein Assays Introduction Bio-Rad offers four colorimetric assays for protein quantitation: the Quick Start Bradford protein assay, the Bio-Rad protein assay

More information

The Determination of an Equilibrium Constant

The Determination of an Equilibrium Constant The Determination of an Equilibrium Constant Chemical reactions occur to reach a state of equilibrium. The equilibrium state can be characterized by quantitatively defining its equilibrium constant, K

More information

Molecular Spectroscopy

Molecular Spectroscopy Molecular Spectroscopy UV-Vis Spectroscopy Absorption Characteristics of Some Common Chromophores UV-Vis Spectroscopy Absorption Characteristics of Aromatic Compounds UV-Vis Spectroscopy Effect of extended

More information

7 Electrophoresis. µ proportional to Q

7 Electrophoresis. µ proportional to Q 7 Electrophoresis Objectives: A) To perform agarose gel electrophoresis of the proteins isolated in last week's experiment and B) to interpret the banding patterns produced by these proteins. Introduction:

More information

Bovine Vitamin B12 (VB12) ELISA Kit

Bovine Vitamin B12 (VB12) ELISA Kit Bovine Vitamin B12 (VB12) ELISA Kit Catalog Number. CSB-E14089B For the quantitative determination of endogenic bovine vitamin B12 (VB12) concentrations in serum, plasma, tissue homogenates. This package

More information

Chemistry 111 Laboratory Experiment 7: Determination of Reaction Stoichiometry and Chemical Equilibrium

Chemistry 111 Laboratory Experiment 7: Determination of Reaction Stoichiometry and Chemical Equilibrium Chemistry 111 Laboratory Experiment 7: Determination of Reaction Stoichiometry and Chemical Equilibrium Introduction The word equilibrium suggests balance or stability. The fact that a chemical reaction

More information

The Determination of an Equilibrium Constant

The Determination of an Equilibrium Constant The Determination of an Equilibrium Constant Computer 10 Chemical reactions occur to reach a state of equilibrium. The equilibrium state can be characterized by quantitatively defining its equilibrium

More information

Copyright 1999 2010 by Mark Brandt, Ph.D. 12

Copyright 1999 2010 by Mark Brandt, Ph.D. 12 Introduction to Absorbance Spectroscopy A single beam spectrophotometer is comprised of a light source, a monochromator, a sample holder, and a detector. An ideal instrument has a light source that emits

More information

SDS-PAGE. (June 23, 2005)

SDS-PAGE. (June 23, 2005) SDS-PAGE (June 23, 2005) GATHER REAGENTS & MATERIALS 30% acrylamide/0.8% bisacrylamide (30:1) 4X Tris. Cl/SDS, ph 8.8 4X Tris. Cl/SDS, ph 6.8 Ammonium persulfate, 10% (Make fresh each time.) SDS electrophoresis

More information

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry Jon H. Hardesty, PhD and Bassam Attili, PhD Collin College Department of Chemistry Introduction: In the last lab

More information

Instructions and lab report for the practical lesson on biochemistry. Task 1: Qualitative estimation of protein in CSF (Pandy s test)

Instructions and lab report for the practical lesson on biochemistry. Task 1: Qualitative estimation of protein in CSF (Pandy s test) Date... Name... Group... Instructions and lab report for the practical lesson on biochemistry Topic: Biochemical examination of cerebrospinal fluid Task 1: Qualitative estimation of protein in CSF (Pandy

More information

I. ACID-BASE NEUTRALIZATION, TITRATION

I. ACID-BASE NEUTRALIZATION, TITRATION LABORATORY 3 I. ACID-BASE NEUTRALIZATION, TITRATION Acid-base neutralization is a process in which acid reacts with base to produce water and salt. The driving force of this reaction is formation of a

More information

Colorimetric Determination of Iron in Vitamin Tablets

Colorimetric Determination of Iron in Vitamin Tablets Cautions: 6 M hydrochloric acid is corrosive. Purpose: To colorimetrically determine the mass of iron present in commercial vitamin tablets using a prepared calibration curve. Introduction: Iron is considered

More information

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND #3. Acid - Base Titrations 27 EXPERIMENT 3. ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND Carbonate Equilibria In this experiment a solution of hydrochloric

More information

Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information

Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information 1 Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information Instructions for the Operation of the Cary 300 Bio UV-Visible Spectrophotometer See the Thermo OMNIC Help reference on page 49. Ultraviolet-Visible

More information

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit Catalog No: E0479r 96 Tests Operating instructions www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH

More information

LAB PROCEDURE Alpha-Amino Nitrogen by NOPA

LAB PROCEDURE Alpha-Amino Nitrogen by NOPA LAB PROCEDURE Alpha-Amino Nitrogen by NOPA From: Method by Dr. Christian Butzke, U.C. Davis. The reagents have been changed slightly for better shelf life. In the original method, NaOH, boric acid, NAC,

More information

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit Catalog No. CSB-E15852c (96T) This immunoassay kit allows for the in vitro quantitative determination of canine CK-MB concentrations in serum and plasma.

More information

THE ACTIVITY OF LACTASE

THE ACTIVITY OF LACTASE THE ACTIVITY OF LACTASE Lab VIS-8 From Juniata College Science in Motion Enzymes are protein molecules which act to catalyze the chemical reactions in living things. These chemical reactions make up the

More information

Assay Qualification Template for Host Cell Protein ELISA

Assay Qualification Template for Host Cell Protein ELISA Assay Qualification Template for Host Cell Protein ELISA Introduction: With ever increasing importance being placed on host cell protein (HCP) removal during the purification process, it is critical to

More information

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb Document: AND Lead 100 7 2013 Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb July, 2013 Edition 1 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of Contents

More information

CHEM 161: Beer s Law and Analysis of a Sports Drink

CHEM 161: Beer s Law and Analysis of a Sports Drink CHEM 161: Beer s Law and Analysis of a Sports Drink Introduction Although sunlight appears white, it contains a spectrum of colors. A rainbow actually shows this range of colors in visible light: violet,

More information